• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • 3
  • 1
  • Tagged with
  • 7
  • 7
  • 4
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Nanotechnologies et matériaux de construction : mécanismes de relargage des nanomatériaux durant l’utilisation et la dégradation des ciments photocatalytiques / Nanotechnologies and building materials : nanomaterials release mechanisms during their use and photocatalytic cement degradation

Bossa, Nathan 22 May 2015 (has links)
La production à l'échelle industrielle et la diversité d'utilisation des nano-objets manufacturés, leurs agrégats et agglomérats (NOAA) et leur possible libération dans l'environnement aquatique naturel ont conduit à une préoccupation croissante parmi la communauté scientifique des sciences de l'environnement et des nanotechnologies. Parmi eux, les ciments photocalytiques sont basés sur la propriété photocatalytique de NOAA-TiO2 ajoutés dans la matrice du ciment. Lors de l'exposition au rayonnement UV, les NOAA-TiO2 provoquent l‘oxydation (i.e. dégradation) des composés adsorbés à la surface du ciment. Sa validation environnementale est requise, en termes d'impacts et risques associés à l'incorporation des NOAA-TiO2. Le but de cette étude est de déterminer les mécanismes de relargage des NOAA-TiO2 incorporés dans le ciment autonettoyant durant le processus de vieillissement et d’identifier les paramètres qui pourraient le contrôler. Les éléments relargués (fractions particulaires et solubles) et leurs cinétiques ont été quantifiés par ICP-OES et caractérisés par MET. Nous avons ensuite analysé la phase solide (du cœur à la couche altérée) en utilisant plusieurs techniques aux rayons X, la DRX (diffraction des rayons X), μ-XRF (micro X-Ray spectroscopie) et une combinaison sans précédent de nano et micro X-ray tomographie pour effectuer une caractérisation complète de la matrice du ciment altéré comprenant la structure de pores. / The industrial scale production and wide variety of applications of manufactured nano-object, their aggregates and agglomerates (NOAA) and their possible release into the natural aquatic environment have produced an increasing concern among the nanotechnology and environmental science community.Among them, the photocatalytic cements are based on the photocatalytic property of TiO2-NOAA added in the cement matrix. During continuous UV radiation exposure, TiO2-NOAA lead to the oxidation (i.e. degradation) of compounds adsorbed at the cement surface. Such NOAA application in building construction is promising as it exhibits improved properties but its environmental validation (in terms of impacts and risks associated with the incorporation of TiO2 NOAA) is also required.The aim of this study is to determine the mechanisms of TiO2-NOAA release from a self-cleaning cement during aging process and to identify cement parameters controlling it.. The elements released (particulate and soluble fractions) and their kinetic were quantified by ICP-OES and characterized with TEM. We analyzed the solid phase (core to altered layer) using several X-ray based techniques: XRD (X-Ray Diffraction), µ-XRF (micro X-Ray Spectroscopy) and an unprecedented combination of nano and micro X-ray computed tomography to perform a original and omplete altered cement matrix characterization including pore structure.
2

Evolution de la microstructure lors du frittage de capacités céramiques multicouches : nanotomographie et simulations discrètes.

Yan, Zilin 17 October 2013 (has links) (PDF)
Les condensateurs multicouches en céramique (Multilayer Ceramic Capacitors, MLCCs) sont des composants passifs clés de l'électronique moderne. Les MLCCs sont constitués d'une alternance d'électrodes métalliques et de couches diélectriques de céramique. Les puces ultraminces sont composées de mélanges de couches micrométriques métalliques et céramiques et d'additifs de céramique de taille nano. Un certain nombre de défauts tels que des fissures, des délaminations des couches et des discontinuités au sein de l'électrode, peuvent survenir dans la fabrication de ces MLCCs ultraminces. Un dispositif expérimental à rayons X (TXM, Transmission X-ray Microscope) avec une résolution spatiale de 30 nm au synchrotron APS (Advanced Photon Source, USA) a été utilisé pour caractériser un volume cylindrique représentatif de Ø 20 µm × 20 µm extrait d'une puce 0603 (1,6 mm × 0,8 mm) au nickel (Ni) + titanate de baryum (BaTiO3, ou BT) avant et après frittage sous argon hydrogéné (2%). La tomographie 3D de la microstructure montre que les discontinuités de l'électrode finale sont liées à des hétérogénéités initiales dans les couches d'électrodes. La radiographie in-situ aux rayons X pendant le frittage (vitesse de chauffage de 10 °C/mn, température de maintien à 1200 °C pendant 1 heure, puis refroidissement à 15 oC/min) d'un volume représentatif d'électrode au palladium (+ baryum-néodyme-titanate) confirme bien que les discontinuités dans l'électrode proviennent de l'hétérogénéité initiale de la poudre, qui est lié à la nature du compactage d'un matériau particulaire. La discontinuité se produit à l'étape précoce du cycle de frittage. A ce stade, l'électrode métallique commence à fritter tandis que le matériau diélectrique peut être considéré comme un substrat inerte qui contraint le frittage de l'électrode.Des études corrélatives utilisant un FIB-SEM (Focused Ion Beam Scanning Electron-microscopie) en tomographie à haute résolution (5 × 5 × 5 nm3) ont été effectuées sur des échantillons MLCC à vert et frittés. Elles confirment que la résolution de la nanotomographie X est suffisante pour étudier l'évolution des hétérogénéités. Cependant la tomographie par FIB permet à la nanotomographie X d'être réinterprétée avec plus de précision. D'autre part, le FIB fournit les paramètres des particules pour les simulations DEM.La méthode des éléments discrets (DEM) a été utilisée pour simuler la microstructure du système multicouche lors du frittage. Tout d'abord, le frittage de la matrice de nickel avec inclusions BT a été simulé en utilisant le code dp3D. Nous avons pu montrer que la vitesse de densification de la matrice diminue avec l'augmentation la fraction volumique d'inclusions et avec la diminution de la taille des inclusions. Pour une fraction volumique donnée, et une taille d'inclusions donnée, une meilleure dispersion des inclusions conduit à un retard plus marqué de la densification du frittage de la matrice de nickel.Le co-frittage de multicouches de BT/Ni/BT a été simulé en tenant compte des informations collectées à partir de la tomographie FIB-SEM à résolution élevée (taille des particules, distribution de taille, hétérogénéités, et pores). On constate que les discontinuités d'électrodes proviennent des hétérogénéités initiales dans le comprimé à vert et se forment au début de frittage sous contrainte. Ces résultats de simulation sont en bonne correspondance avec les observations expérimentales. Une étude paramétrique indique que les discontinuités d'électrodes peuvent être minimisées par l'homogénéisation de la compacité, par l'augmentation de l'épaisseur des électrodes et par l'utilisation d'un chauffage rapide.A partir des résultats expérimentaux et des simulations DEM, une conclusion générale peut être avancée: la discontinuité finale provient de l'hétérogénéité initiale dans les couches d'électrodes et survient à un stade précoce de frittage lorsque les couches diélectriques contraignent les couches d'électrodes
3

Durabilité des convertisseurs électrochimiques haute température à oxydes solides : une étude expérimentale et de modélisation basée sur la caractérisation au synchrotron par nanotomographie des rayons X / Durability of solid oxide cells : an experimental and modelling investigation based on synchrotron X-ray nano-tomography characterization

Hubert, Maxime 24 May 2017 (has links)
Ce travail porte sur l’étude de la dégradation des convertisseurs électrochimiques haute température à oxydes solides. Une approche couplant des tests électrochimiques, des caractérisations post-mortem avancées et une modélisation multi-échelle a été mise en place afin d’établir les liens entre les performances, la microstructure des électrodes et leur dégradation. Dans ce but, des essais de durabilité de plus de mille heures ont été menés dans différentes conditions opératoires. La microstructure des électrodes a été reconstruite par nano-holotomographie des rayons X pour la cellule de référence avant et après vieillissement. Une attention particulière a été apportée à la mesure de la résolution spatiale et à la fiabilisation du protocole expérimental. Grâce aux volumes 3D, les propriétés microstructurales de l’électrode H2 en Ni-YSZ ont été quantifiées pour les cellules à l’état initial et vieillies. Un modèle physique d’agglomération des particules de Nickel a ensuite été ajusté sur les analyses tridimensionnelles et intégré dans une structure de modélisation multi-échelle développée au laboratoire. Il a auparavant été nécessaire de compléter l’outil numérique avec un module spécifique dédié aux matériaux composant l’électrode à oxygène fait avec un conducteur mixte ionique-électronique. Une fois le modèle validé sur des courbes de polarisation expérimentales, il a été utilisé pour quantifier la contribution de l’agglomération du Nickel sur les pertes de performances mesurées expérimentalement en mode pile à combustible et électrolyse. / This work aims at a better understanding of the high temperature Solid Oxide Cells degradation. An approach based on electrochemical tests, advanced post-test characterizations and multi-scale models has been used to investigate the links between the performances, the electrodes microstructure and their degradation. In that goal, long-term durability tests have been performed over thousand hours in different operating conditions. Electrode microstructures have been reconstructed by X-ray nano-holotomography for the pristine and the aged cells. It is worth noting that a special attention has been paid to improve both the process reliability for the tomographic experiments as well as the spatial resolution of the 3D reconstructed images. Thanks to the valuable 3D volumes, the Ni-YSZ microstructural properties of the H2 electrode have been quantified for the fresh and the aged samples. Then, a physically-based model for Nickel particle agglomeration has been adjusted on the microstructural parameters obtained by the 3D analysis and implemented in an in-house multi-scale modelling framework. Beforehand, it has been necessary to enrich the available numerical tool with a specific module dedicated to the oxygen electrode made in Mixed Ionic Electronic Conducting materials. Once validated on polarisation curves, the completed model has been used to quantify the contribution of Nickel agglomeration on the experimental degradation rates recorded in fuel cell and electrolysis modes.
4

Evolution de la microstructure lors du frittage de capacités céramiques multicouches : nanotomographie et simulations discrètes. / Microstructure Evolutions during sintering of multilayer ceramic capacitors : nanotomography and discrete simulations

Yan, Zilin 17 October 2013 (has links)
Les condensateurs multicouches en céramique (Multilayer Ceramic Capacitors, MLCCs) sont des composants passifs clés de l'électronique moderne. Les MLCCs sont constitués d'une alternance d'électrodes métalliques et de couches diélectriques de céramique. Les puces ultraminces sont composées de mélanges de couches micrométriques métalliques et céramiques et d'additifs de céramique de taille nano. Un certain nombre de défauts tels que des fissures, des délaminations des couches et des discontinuités au sein de l'électrode, peuvent survenir dans la fabrication de ces MLCCs ultraminces. Un dispositif expérimental à rayons X (TXM, Transmission X-ray Microscope) avec une résolution spatiale de 30 nm au synchrotron APS (Advanced Photon Source, USA) a été utilisé pour caractériser un volume cylindrique représentatif de Ø 20 µm × 20 µm extrait d'une puce 0603 (1,6 mm × 0,8 mm) au nickel (Ni) + titanate de baryum (BaTiO3, ou BT) avant et après frittage sous argon hydrogéné (2%). La tomographie 3D de la microstructure montre que les discontinuités de l'électrode finale sont liées à des hétérogénéités initiales dans les couches d'électrodes. La radiographie in-situ aux rayons X pendant le frittage (vitesse de chauffage de 10 °C/mn, température de maintien à 1200 °C pendant 1 heure, puis refroidissement à 15 oC/min) d’un volume représentatif d'électrode au palladium (+ baryum-néodyme-titanate) confirme bien que les discontinuités dans l'électrode proviennent de l'hétérogénéité initiale de la poudre, qui est lié à la nature du compactage d'un matériau particulaire. La discontinuité se produit à l'étape précoce du cycle de frittage. A ce stade, l'électrode métallique commence à fritter tandis que le matériau diélectrique peut être considéré comme un substrat inerte qui contraint le frittage de l’électrode.Des études corrélatives utilisant un FIB-SEM (Focused Ion Beam Scanning Electron-microscopie) en tomographie à haute résolution (5 × 5 × 5 nm3) ont été effectuées sur des échantillons MLCC à vert et frittés. Elles confirment que la résolution de la nanotomographie X est suffisante pour étudier l’évolution des hétérogénéités. Cependant la tomographie par FIB permet à la nanotomographie X d’être réinterprétée avec plus de précision. D'autre part, le FIB fournit les paramètres des particules pour les simulations DEM.La méthode des éléments discrets (DEM) a été utilisée pour simuler la microstructure du système multicouche lors du frittage. Tout d'abord, le frittage de la matrice de nickel avec inclusions BT a été simulé en utilisant le code dp3D. Nous avons pu montrer que la vitesse de densification de la matrice diminue avec l'augmentation la fraction volumique d'inclusions et avec la diminution de la taille des inclusions. Pour une fraction volumique donnée, et une taille d’inclusions donnée, une meilleure dispersion des inclusions conduit à un retard plus marqué de la densification du frittage de la matrice de nickel.Le co-frittage de multicouches de BT/Ni/BT a été simulé en tenant compte des informations collectées à partir de la tomographie FIB-SEM à résolution élevée (taille des particules, distribution de taille, hétérogénéités, et pores). On constate que les discontinuités d'électrodes proviennent des hétérogénéités initiales dans le comprimé à vert et se forment au début de frittage sous contrainte. Ces résultats de simulation sont en bonne correspondance avec les observations expérimentales. Une étude paramétrique indique que les discontinuités d'électrodes peuvent être minimisées par l'homogénéisation de la compacité, par l’augmentation de l'épaisseur des électrodes et par l’utilisation d’un chauffage rapide.A partir des résultats expérimentaux et des simulations DEM, une conclusion générale peut être avancée: la discontinuité finale provient de l'hétérogénéité initiale dans les couches d'électrodes et survient à un stade précoce de frittage lorsque les couches diélectriques contraignent les couches d'électrodes / Multi-Layer Ceramic Capacitors (MLCCs) are key passive components in modern electronics. MLCCs consist of alternating metal electrode and ceramic dielectrics layers. In ultrathin MLCC chips, the micrometric layers are composed of submicrometric metal and ceramic powders and nano sized ceramic additives. A number of defects such as cracks, delamination of layers and electrode discontinuity and homogeneity, may arise in the processing of these ultrathin MLCCs. Synchrotron (Advanced Photon Source, Argonne National Laboratory, IL, USA) X-ray based Transmission X-ray Microscope (TXM) with spatial resolution of 30 nm was used to characterize a representative cylindrical volume of Ø 20 µm × 20 µm extracted from a 0603 (1.6 mm×0.8 mm) case size Nickel (Ni)-electrode Barium Titanate (BaTiO3, or BT)-based MLCC before and after sintering under 2H2%+Ar atmosphere. 3D tomographic microstructure imaging shows that the final electrode discontinuity is linked to the initial heterogeneity in the electrode layers. In situ X-ray radiography of sintering (heating ramp of 10 oC, holding at 1200 oC for 1 hour, cooling ramp -15 oC) of a Palladium (Pd) electrode BNT (Barium-neodymium-titanate) based MLCC representative volume was also carried out. It confirmed that discontinuities in the electrode originate from the initial heterogeneities, which are linked to the very particulate nature of the powder material. The discontinuity occurs at the early stage of the sintering cycle. At this stage, the electrode starts to sinter while the dielectric material may be considered as a constraining substrate. Correlative studies using Focused Ion Beam - Scanning Electron Microscope (FIB - SEM) tomography were conducted on green and sintered MLCC samples at high resolution (5 × 5 × 5 nm3). FIB images confirmed that the resolution of the X-ray nCT is sufficient to deal with these heterogeneity evolutions. Still, FIB tomography allows the X-ray nCT to be re-interpreted more accurately. Also, it provides detailed particulate parameters for the DEM simulations.The DEM was used to simulate the microstructure of a multilayer system during sintering. First, the sintering of Nickel matrix with BT inclusions was simulated using the dp3D codes. It is found that the densification rate of the matrix decreases with increasing volume fraction of inclusions and with decreasing size of inclusions. For a given volume fraction and size of inclusions, a better dispersion of the inclusions results in a stronger retardation of the densification kinetics of the nickel matrix.Co-sintering of BT/Ni/BT multilayers was simulated with DEM by taking into account the particulate nature collected from the high resolution FIB nanotomography (FIB-nT) data, such as particle size, size distribution, heterogeneities, pores, and geometry. It is found that the electrode discontinuities originate from the initial heterogeneities in the green compact and form at the early stage of sintering under constraint, in good correspondence to the experimental observations. Parametric studies suggest that electrode discontinuities can be minimized by homogenizing the packing density and thickness of the electrodes and using a fast heating rate.Based on both experimental and DEM simulation results, a general conclusion is reached: the final discontinuity originates from the initial heterogeneity in the electrode layers and occurs at the early stage of sintering when the dielectric layers constrain the electrode layers.
5

Relation entre structure, réactivité et interactions cellulaires de nanotubes inorganiques : cas des imogolites / Relating structure, reactivity and cellular interactions of inorganic nanotubes : case of imogolites

Avellan, Astrid 09 December 2015 (has links)
Aujourd’hui, les difficultés pour établir des liens entre caractéristiques des nanomatériaux et réponses biologiques sont principalement issues du manque de contrôle de la synthèse des nanomatériaux, ne permettant pas de faire varier leurs paramètres physico-chimiques clés une à une.Pour identifier certains mécanismes gouvernant la toxicité des nanomatériaux nous avons utilisé un nanotube inorganique modèle dont la synthèse est bien contrôlée : les Ge-imogolites. Les effets de la longueur, du nombre de parois, de la cristallinité et de la composition chimique des Ge-imogolites ont été étudiés sur une bactérie des sols: Pseudomonas brassicacearum. Il a été identifié que la présence de sites réactifs (en bordure de tubes) induit une toxicité due à une interaction forte des nanotubes avec les cellules bactériennes, ainsi que la génération d’espèces réactives de l’oxygène. Ajouter des sites réactifs via la présence de défauts structuraux augmente la dégradation des tubes ainsi que la rétention d’éléments nutritifs essentiels, ce qui augmente leur toxicité. Enfin, l’ajout de fer dans leur structure transforme les Ge-imogolites en source de fer, qui sont dégradées et deviennent promoteurs de croissance. Dans tous ces cas, les interactions entre nanomatériaux et cellules ont été identifiées comme cruciales pour comprendre et prévenir les effets des nanomatériaux. Ce travail de thèse a également permis de mettre en avant la capacité de nouveaux outils pour le suivi de l’internalisation de nanomatériaux dans les organismes. / Only a few studies of (eco)toxicology linked the physico-chemical properties of nanoparticles to the toxicity mechanisms or the stress they induce. Moreover, no clear conclusions can be drawn at present because of the variability of nanoparticles used in studies. The present study used the inorganic Ge-imogolite nanotubes as a model compound. The toxic effects of length, number of walls, structural defects, and chemical composition were assessed towards the soil bacteria Pseudomonas brassicacearum. Several mechanisms modulating the toxicity of Ge-imogolite were then identified. Indeed, reactive sites at the tube ends induce a slight toxicity via a strong cell interaction and the generation of reactive oxygen species. Creating vacant sites on the surface of Ge-imogolite (ant thus increasing the number of reactive sites), appears to cause a deficiency of nutrients in the culture media correlated with a higher degradation of the tubes, leading to a high bacterial growth decrease. Finally, structural iron incorporation into Ge-imogolite transforms them into an iron source, being degraded and becoming growth promoters. In this work, the new tools capacities for the study of nanomaterials/cells interaction have been studied.
6

Three-dimensional analysis of bone cellular tissue from SR CT Imaging / Analyse tridimensionnelle du tissu cellulaire osseux par tomographie Synchrotron

Dong, Pei 21 February 2014 (has links)
Le système ostéocytaire soulève un intérêt croissant depuis quelques années car il est joue un rôle important dans l'adaptation de l'os. Le système ostéocytaire est inclus dans un réseau poreux dénommé le réseau lacuno-canaliculaire (LCN). L’observation du système ostéocytaire est difficile car les ostéocytes sont profondément enfouies dans la matrice osseuse et difficilement accessible par les techniques optiques. Récemment l’équipe de Creatis a montré la faisabilité d’imager le LCN en 3D grâce à la micro tomographie par rayonnement synchrotron. Toutefois, il n’existe actuellement pas de méthodes d’analyse permettant de quantifier, de façon automatique, le réseau lacuno-canaliculaire en 3D. L’objectif de cette thèse était de développer des méthodes d’analyse d’images permettant d’extraire des paramètres quantitatifs sur le réseau lacuno-canaliculaire. La première partie, consacrée à l’état de l’art. Le chapitre 1 présente les objectifs de ce travail. Le chapitre 2 rappelle les éléments de base sur le tissu osseux et présente les caractéristiques du réseau lacuno-canaliculaire. Le chapitre 3 présente les différentes méthodes d’imagerie utilisées jusqu’à présent pour étudier le réseau lacuno-canaliculaire. Le chapitre 4 présente l’état de l’art sur les paramètres qui sont classiquement utilisés pour caractériser le réseau lacuno-canaliculaire. La seconde partie est consacrée aux contributions de ce travail. Le chapitre 5 présente les deux systèmes expérimentaux de l’ESRF sur lesquels des images d’échantillons osseux ont été acquises. Le chapitre 6 décrit la méthode développée pour la quantification des lacunes ostéocytaires à partir d’images à l’échelle micrométrique. Elle propose de calculer des paramètres issus des moments géométriques ainsi que des paramètres basés sur la notion de volumes intrinsèques. Les méthodes sont appliquées à une série de 13 échantillons acquis en collaboration avec le Laboratoire d’Imagerie Paramétrique, Paris. Les résultats obtenus sont comparés et discutés par rapport à ceux de la littérature. Le chapitre 7 décrit la quantification des canalicules reliant les ostéocytes à partir d’images à l’échelle sous-micrométrique. En particulier, nous nous sommes intéressées à estimer le nombre de canalicules issues d’une lacune ostéocytaire, paramètre encore jamais mesuré en 3D. L’évolution de ce paramètre en fonction de la distance au centre de la lacune a permis de mettre en évidence et de quantifier la ramification des canalicules. Le chapitre 8 propose l’application des méthodes développées à une série d’échantillons acquis en collaboration le groupe de Sharmila Majumdar à l’université de San Francisco. Dans ce chapitre, nous avons travaillé sur une nouvelle méthode de segmentation du réseau lacuno-canaliculaire basée sur une méthode de chemins géodésiques. Les premiers résultats acquis sur 8 échantillons humains d’âges différents sont présentés. Finalement, le chapitre 9 conclut ce travail et présente des perspectives. / The osteocyte system has raised increasing interest in the recent years, since it is hypothesized to play an important role in orchestrating bone adaptation through mechanosensation and bone mechanotransduction mechanism. The osteocytes are deeply buried within the bone matrix, where their bodies are encysted in cavities called lacunae and their stellular processes are enclosed in tunnels called canaliculi. Together, they formed the lacuno-canalicular network (LCN). The geometry of the LCN is of importance since it is supposed to potentially affect and reflect the viability of the osteocyte and is supposed to be related to biomechanical constraints at the cell level. However, studying the LCN is quite challenging, due to limitations in an ideal imaging modality and the lack of quantitative analysis tools. In this thesis, we propose computational efficient and automated methods to quantify the 3D morphological properties of the LCN from synchrotron radiation (SR) micro / nano-CT images. For image acquisition, we used the SR micro/nano-CT setups installed on beamlines ID19 and ID22 at ESRF. A series of human cortical samples were imaged with spatial resolutions ranging between 3.5 µm to 60 nm. For the 3D assessment of lacunae, we used an image moment-based approach to calculate the volume, length, width, height and anisotropy of each osteocyte lacuna. We employed a fast algorithm to further calculate the surface area, the Euler number and the SMI of each lacuna. Validation of segmentation and experimental results on 13 bone samples are presented. For the 3D assessment of canaliculi, we propose a method to quantify the canalicular ramification around each lacuna. After segmentation, our method first labels each lacuna from the LCN. Then, a signature of the numbers of canaliculi at different distances from the lacunar surface is estimated through the calculation of topological parameters. Validation of this method and statistical results a large 3D SR micro-CT image of a human femoral bone sample are reported. We also improved the segmentation of the canaliculi and illustrated the feasibility of the application on a series of bone samples. We investigated a segmentation approach based on minimum cost paths and geodesic voting. A parallel computation scheme was implemented to reduce the computation times. The LCN was characterized by using the previous methods. Besides, we introduced the parameters from the Voronoi tessellation. Statistical results are reported on 8 large 3D micro-CT images, including around a hundred lacunae and the canaliculi. Future works will concern the improvement of canaliculi segmentation of from images at 300 nm as well as its evaluation and further characterization of LCN from SR CT images at both 300 nm and 50 nm. This work opens many perspectives for a better knowledge of the physiopathology of bone at the cellular scale.
7

Iterative tomographic X-Ray phase reconstruction / Reconstruction tomographique itérative de phase

Weber, Loriane 30 September 2016 (has links)
L’imagerie par contraste de phase suscite un intérêt croissant dans le domaine biomédical, puisqu’il offre un contraste amélioré par rapport à l’imagerie d’atténuation conventionnelle. En effet, le décalage en phase induit par les tissus mous, dans la gamme d’énergie utilisée en imagerie, est environ mille fois plus important que leur atténuation. Le contraste de phase peut être obtenu, entre autres, en laissant un faisceau de rayons X cohérent se propager librement après avoir traversé un échantillon. Dans ce cas, les signaux obtenus peuvent être modélisés par la diffraction de Fresnel. Le défi de l’imagerie de phase quantitative est de retrouver l’atténuation et l’information de phase de l’objet observé, à partir des motifs diffractés enregistrés à une ou plusieurs distances. Ces deux quantités d’atténuation et de phase, sont entremêlées de manière non-linéaire dans le signal acquis. Dans ces travaux, nous considérons les développements et les applications de la micro- et nanotomographie de phase. D’abord, nous nous sommes intéressés à la reconstruction quantitative de biomatériaux à partir d’une acquisition multi-distance. L’estimation de la phase a été effectuée via une approche mixte, basée sur la linéarisation du modèle de contraste. Elle a été suivie d’une étape de reconstruction tomographique. Nous avons automatisé le processus de reconstruction de phase, permettant ainsi l’analyse d’un grand nombre d’échantillons. Cette méthode a été utilisée pour étudier l’influence de différentes cellules osseuses sur la croissance de l’os. Ensuite, des échantillons d’os humains ont été observés en nanotomographie de phase. Nous avons montré le potentiel d’une telle technique sur l’observation et l’analyse du réseau lacuno-canaliculaire de l’os. Nous avons appliqué des outils existants pour caractériser de manière plus approfondie la minéralisation et les l’orientation des fibres de collagènes de certains échantillons. L’estimation de phase, est, néanmoins, un problème inverse mal posé. Il n’existe pas de méthode de reconstruction générale. Les méthodes existantes sont soit sensibles au bruit basse fréquence, soit exigent des conditions strictes sur l’objet observé. Ainsi, nous considérons le problème inverse joint, qui combine l’estimation de phase et la reconstruction tomographique en une seule étape. Nous avons proposé des algorithmes itératifs innovants qui couplent ces deux étapes dans une seule boucle régularisée. Nous avons considéré un modèle de contraste linéarisé, couplé à un algorithme algébrique de reconstruction tomographique. Ces algorithmes sont testés sur des données simulées. / Phase contrast imaging has been of growing interest in the biomedical field, since it provides an enhanced contrast compared to attenuation-based imaging. Actually, the phase shift of the incoming X-ray beam induced by an object can be up to three orders of magnitude higher than its attenuation, particularly for soft tissues in the imaging energy range. Phase contrast can be, among others existing techniques, achieved by letting a coherent X-ray beam freely propagate after the sample. In this case, the obtained and recorded signals can be modeled as Fresnel diffraction patterns. The challenge of quantitative phase imaging is to retrieve, from these diffraction patterns, both the attenuation and the phase information of the imaged object, quantities that are non-linearly entangled in the recorded signal. In this work we consider developments and applications of X-ray phase micro and nano-CT. First, we investigated the reconstruction of seeded bone scaffolds using sed multiple distance phase acquisitions. Phase retrieval is here performed using the mixed approach, based on a linearization of the contrast model, and followed by filtered-back projection. We implemented an automatic version of the phase reconstruction process, to allow for the reconstruction of large sets of samples. The method was applied to bone scaffold data in order to study the influence of different bone cells cultures on bone formation. Then, human bone samples were imaged using phase nano-CT, and the potential of phase nano-imaging to analyze the morphology of the lacuno-canalicular network is shown. We applied existing tools to further characterize the mineralization and the collagen orientation of these samples. Phase retrieval, however, is an ill-posed inverse problem. A general reconstruction method does not exist. Existing methods are either sensitive to low frequency noise, or put stringent requirements on the imaged object. Therefore, we considered the joint inverse problem of combining both phase retrieval and tomographic reconstruction. We proposed an innovative algorithm for this problem, which combines phase retrieval and tomographic reconstruction into a single iterative regularized loop, where a linear phase contrast model is coupled with an algebraic tomographic reconstruction algorithm. This algorithm is applied to numerical simulated data.

Page generated in 0.0865 seconds