• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 41
  • Tagged with
  • 41
  • 38
  • 38
  • 35
  • 35
  • 30
  • 14
  • 10
  • 10
  • 10
  • 9
  • 9
  • 9
  • 8
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

A utilização da resposta auditiva de estado estável para estimar limiares auditivos em indivíduos com perda auditiva neurossensorial / Utilization of auditory steady state response to estimate the auditory threshold in individuals with sensorineural hearing loss

Josilene Luciene Duarte 26 March 2007 (has links)
O diagnóstico precoce da perda auditiva tem sido cada vez mais freqüente em virtude dos programas de saúde auditiva que estão sendo implantados em todo o país. Existe, contudo, a necessidade de técnicas e procedimentos que ajudem a identificar, com maior precisão, a presença e o grau da mesma. A Resposta Auditiva de Estado Estável (RAEE) é um procedimento eletrofisiológico que, ao contrário do Potencial Evocado Auditivo de Tronco Encefálico (PEATE) realizado com estímulo tone burst, possibilita avaliar, ao mesmo tempo limiares auditivos com especificidade por freqüência e por orelha, reduzindo assim o tempo do exame. Além disso, ele permite a estimulação até níveis próximos a 130 dBHL, podendo assim medir a audição residual. O objetivo deste estudo foi verificar a aplicabilidade da RAEE para determinar os limiares auditivos nos diferentes graus de perda auditiva neurossensorial. Foram avaliados 65 indivíduos com perda auditiva neurossensorial, sendo que 48 apresentaram alteração neurossensorial (coclear) de grau leve até profundo, e idades entre sete e 30 anos; e 17 apresentaram alteração neurossensorial (Neuropatia Auditiva/Dessincronia Auditiva) e idades entre 0,6 e cinco anos. A avaliação foi composta por Audiometria Tonal Liminar (ATL) e pesquisa da RAEE para o grupo com alteração neurossensorial (coclear) e somente a pesquisa da RAEE para o grupo com alteração neurossensorial (NA/DA). Os resultados demonstraram que, nos indivíduos com perda auditiva neurossensorial (coclear), houve associação significante (p<0,01) entre os limiares obtidos na ATL e RAEE para as freqüências de 0,5 a 4 kHz, ocorrendo uma maior concordância para graus de deficiências auditivas mais acentuadas. Já na perda auditiva neurossensorial (NA/DA), a RAEE mostrou ausência de resposta na maioria dos indivíduos avaliados. Concluímos que a RAEE pode predizer os limiares da ATL com maior precisão para os graus de perda auditiva mais acentuados, e que a utilização deste procedimento não mostrou informações adicionais que podem contribuir para o diagnóstico da perda auditiva neurossensorial (NA/DA). / The diagnosis of hearing loss in the first months of life has been increasingly frequent due to hearing health programs established throughout the country. Thus, techniques and procedures should be developed for accurate identification of the presence and severity of hearing loss, in a population whose motor and cognitive development does not allow response to behavioral methods. The auditory steady state response (ASSR) is an electrophysiological procedure which, different from the brainstem evoked response audiometry (BERA) conducted with tone burst stimuli, allows the establishment of hearing thresholds at multiple frequencies and for both ears, thus reducing the examination time. Moreover, it allows measurement of residual hearing due to the possibility of stimulation at levels close to 130 dBHL. Therefore, the present study aimed to investigate the applicability of ASSR for establishment of hearing thresholds in different severities of sensorineural hearing loss. A total of 65 individuals with sensorineural hearing loss were evaluated, among whom 48 presented mild to deep sensorineural disorder (cochlear), at the age range 7 to 30 years; and 17 presented sensorineural disorder (neuropathy/hearing dyssynchrony) aged 0.6 to 5 years. The evaluation comprised pure-tone threshold audiometry (PTTA) and ASSR analysis for the group with deep sensorineural disorder (cochlear) and only ASSR analysis for the group with sensorineural disorder (neuropathy/hearing dyssynchrony). The results demonstrated that, for individuals with deep sensorineural hearing loss (cochlear), there was significant association (p<0.01) between the thresholds obtained by PTTA and ASSR at frequencies from 0.5 to 4 kHz, with higher agreement in cases with more severe hearing loss. On the other hand, for the sensorineural hearing loss (neuropathy/hearing dyssynchrony), the ASSR was absent in most individuals analyzed. It was concluded that there is significant association between the thresholds obtained by PTTA and ASSR, and that the utilization of this procedure did not provide additional information that might contribute to the diagnosis of sensorineural hearing loss (neuropathy/hearing dyssynchrony), when compared to BERA
22

Uso de dexametasona tópica isolada e associada ao ácido hialurônico na preservação auditiva de pacientes submetidos à cirurgia de implante coclear / Hearing preservation using topical dexamethasone isolated and associated with hyaluronic acid in cochlear implantation

Bernardo Faria Ramos 26 September 2013 (has links)
INTRODUÇÃO: A introdução dos princípios da soft surgery desencadeou busca constante pela preservação auditiva, principalmente após a expansão dos critérios de inclusão para a cirurgia do implante coclear. Esses princípios cirúrgicos, associados a novos modelos de eletrodos e ao uso de fármacos no intraoperatório, têm sido utilizados a partir do melhor conhecimento da anatomia da orelha interna e da repercussão dos mecanismos inflamatórios desencadeados pelo trauma de inserção dos eletrodos. O objetivo deste estudo é avaliar o efeito de dexametasona tópica isolada e associada ao ácido hialurônico no intraoperatório de pacientes com audição residual submetidos ao implante coclear na preservação dos limiares tonais dos mesmos. MÉTODO: Foram avaliados 18 pacientes adultos com surdez severaprofunda submetidos à cirurgia de implante coclear divididos em 3 grupos: Implante coclear como grupo-controle, grupo 1; implante coclear com uso de dexametasona tópica no intraoperatório, grupo 2; e implante coclear com uso de dexametasona tópica associada ao ácido hialurônico no intraoperatório, grupo 3. Foram comparadas as médias dos limiares tonais nas frequências de 125, 250 e 500 Hz e nas frequências de 1000, 2000 e 4000 Hz no pré-operatório e no pós-operatório. RESULTADOS: A diferença entre as médias dos limiares tonais nas frequências baixas obtidas no 6º mês de pós-operatório e no pré-operatório foi de 28,03 dB + 6,77 dB no grupo 1, 30 dB + 14,53 dB no grupo 2 e 7,23 dB + 6,12 dB no grupo 3. Houve diferença estatisticamente significante dos valores do grupo 3 em relação ao grupo 1 e 2 (p = 0,002). A diferença entre as médias dos limiares tonais nas frequências altas obtidas no 6º mês de pós-operatório e no pré-operatório foi de 11,12 dB (DP + 9,71 dB) no grupo 1, 22,77 dB (DP + 12,79 dB) e 3,89 dB (DP + 3,1 dB). Houve diferença estatística entre os grupos 2 e 3 (p = 0,01). CONCLUSÕES: A associação do uso tópico de dexametasona e ácido hialurônico no intraoperatório de pacientes submetidos à cirurgia do implante coclear foi significantemente superior ao grupo controle e ao grupo no qual foi utilizado apenas a dexametasona tópica na preservação dos limiares auditivos. Por outro lado, o uso isolado de dexametasona tópica não demonstrou resultados superiores na preservação dos limiares acústicos quando comparado ao grupo controle / INTRODUCTION: The expansion of candidacy criteria for cochlear implantation led to a constant care for hearing preservation. The in-depth knowledge of the anatomy and function of the inner ear as well as the inflammatory repercussion caused by the insertion trauma led to the development of soft surgery principles, new electrode designs and pharmacotherapy. The purpose of this study was to compare the effects of topical dexamethasone isolated and associated with hyaluronic acid in hearing preservation in cochlear implantation. METHOD: Eighteen severely to profoundly hearing impaired adult patients were evaluated and divided into 3 groups: Cochlear implantation as a control group in group 1, cochlear implantation using topical dexamethasone intraoperatively in group 2 and cochlear implantation using topical dexamethasone associated with hyaluronic acid intraoperatively in group 3. Preimplant and postimplant low frequency and high frequency pure-tone average (PTA) from 125, 250, 500 Hz and 1000, 2000, 4000 Hz were calculated and compared from unaided audiograms. RESULTS: The mean changes in the low frequency PTA of preoperative and postoperative thresholds were 28.03 dB + 6.77 dB in group 1, 30 dB + 14.53 dB in group 2 and 7.23 dB + 6.12 dB in group 3. There was statistical difference comparing group 3 with group 1 and 2 (p = 0.002). The mean changes in the high frequency PTA of preoperative and postoperative thresholds were 11.12 dB + 9.71 dB in group 1, 22.77 dB + 12.79 dB e 3.89 dB + 3.1 dB. There was statistical difference between group 2 and 3 (p = 0.01). CONCLUSIONS: The use of topical dexamethasone associated with hyaluronic acid intraoperatively in cochlear implant surgery demonstrated a statistically significant difference in the preservation of low frequency thresholds when compared with the use of isolated topical dexamethasone and a control group. The use of isolated topical dexamethasone was not superior in hearing preservation when compared to a control group
23

A influência das respostas auditivas do estado estável nas respostas auditivas ao implante coclear / Auditory steady-state response influence on cochlear implant auditory response

Chiossi, Julia Santos Costa 28 August 2017 (has links)
Introdução: O potencial evocado auditivo de estado estável (PEAEE) é um exame eletrofisiológico que permite a testagem simultânea e binaural do limiar auditivo por frequência específica. Por seu caráter objetivo vem sendo recomendada sua inclusão na bateria de testes para diagnóstico de crianças com deficiência auditiva. A possibilidade de diagnóstico precoce da perda de audição em crianças é fundamental para a redução dos agravos decorrentes da privação sensorial e a tomada de decisão quanto à intervenção adequada, como o uso do implante coclear (IC). A determinação do sucesso do uso do IC é dependente de múltiplos cofatores, entre eles, sugere-se que a presença de audição residual prévia ao implante poderia possibilitar a preservação das vias auditivas e áreas auditivas corticais, proporcionando melhor desenvolvimento das habilidades auditivas e de produção oral da linguagem com o reestabelecimento da entrada sensorial. Objetivo: Verificar a relação entre o PEAEE pré-operatório e a resposta auditiva pós-implante de crianças submetidas ao IC. Casuística e Método: Trata-se de um estudo observacional retrospectivo, desenvolvido a partir da análise de prontuários de pacientes do Hospital das Clínicas da Faculdade de Medicina de Ribeirão Preto, submetidos à cirurgia de IC. Foram incluídas 47 crianças menores de 6 anos à data de realização da cirurgia, diagnosticadas com perda auditiva neurossensorial pré-lingual de grau profundo. Foram coletadas informações audiológicas pré-implantação - PEAEE, PEATE, audiometria comportamental e demais aspectos de caracterização da perda auditiva; a categoria de percepção auditiva e de expressão oral da linguagem antes e após a implantação; além de informações socioeconômicas e da intervenção terapêutica. Resultados: O registro do PEAEE esteve presente em 34 (72,3%) crianças com limiar médio de 89,7 ± 10,2 dB NA na orelha implantada, consideradas as frequências de 0,5; 1; 2 e 4 kHz. A reavaliação foi conduzida em média 7,2 ± 2,1 meses após a cirurgia de IC, quando 23 (49%) sujeitos apresentaram avanço de uma categoria no desenvolvimento da percepção de fala e 4 (8,5%) alcançaram um desempenho dois níveis superior ao da avaliação anterior. O limiar obtido na audiometria em campo com o uso de IC teve média de 44,4 ± 12,4 dB NA, consideradas as frequências de 0,5; 1; 2 e 4 kHz. Quanto à expressão oral da linguagem, 13 (27,6%) crianças tiveram melhora em seu desempenho. Não houve correlação entre os resultados do PEAEE pré-implante e o limiar auditivo (p-valor=0,338) ou a categoria de linguagem (p-valor=0,358) com uso de IC quando controlado pela idade; nem em relação à melhora no desempenho de linguagem oral (p-valor= 0,095). Conclusão: Não houve correlação direta entre o limiar eletrofisiológico mensurado por meio do PEAEE e a resposta auditiva com uso de IC, quando analisados o limiar auditivo comportamental com IC ou a categoria de percepção de fala. / Background: The Auditory Steady State Response (ASSR) is an electrophysiological exam that allows simultaneous and binaural frequency specific testing of hearing thresholds. Considering its objectivity, the test has been recommended for hearing loss diagnosis in young children. This possibility of early identification of hearing impairment is fundamental for minimizing handicaps caused by sensory deprivation and for planning proper intervention, for example, suggesting the use of cochlear implants (CI). The determination of the success of CI prognosis depends on several cofactors. Researchers suggest that residual hearing and hearing thresholds before CI surgery could allow auditory pathways preservation and enable the development of hearing abilities, as well as speech production skills, after the reestablishment of sensory input. Objective: To verify the relation between pre-operatory ASSR and post-CI auditory response in young children. Casuistic and Method: An observational retrospective study was conducted. Medical records were assessed in 47 children, younger than six years old at the CI surgery, diagnosed with sensorineural pre-linguistic hearing loss of profound degree. Information was collected about (a) audiological data - ASSR, ABR, behavioral audiometry, and other hearing loss aspects; (b) category of speech perception and oral language production before and after CI; (c) socioeconomics data and therapy attendance. Results: ASSR record was present in 34 (72.4%) children with mean threshold of 89.7 (10.2 SD) dB HL in the implanted ear, considering the frequencies of 0.5; 1; 2 and 4 kHz. Post-implant evaluation was conducted after a mean of 7.2 (2.1 SD) months of surgery. Then, 23 (49%) subjects enhanced one category of speech perception and four (8.5%) improved two categories, compared to previous evaluation. Field auditory threshold with CI was measure at 44.4 (12.4 SD) dB HL in mean, considering the frequencies of 0.5; 1; 2 and 4 kHz. Analyzing language expression development, 13 (27.6%) children improved their performance. To the age at CI surgery there was no correlation between ASSR thresholds and CI thresholds (p-value=0.338) or speech perception category (p-value=0.358) after CI. No correlation has been found between ASSR and expressive language development (p-value=0.095). Conclusion: There was no direct correlation between electrophysiological thresholds measured by ASSR and hearing response after CI, when analyzed behavioral CI threshold or speech perception.
24

A influência das respostas auditivas do estado estável nas respostas auditivas ao implante coclear / Auditory steady-state response influence on cochlear implant auditory response

Julia Santos Costa Chiossi 28 August 2017 (has links)
Introdução: O potencial evocado auditivo de estado estável (PEAEE) é um exame eletrofisiológico que permite a testagem simultânea e binaural do limiar auditivo por frequência específica. Por seu caráter objetivo vem sendo recomendada sua inclusão na bateria de testes para diagnóstico de crianças com deficiência auditiva. A possibilidade de diagnóstico precoce da perda de audição em crianças é fundamental para a redução dos agravos decorrentes da privação sensorial e a tomada de decisão quanto à intervenção adequada, como o uso do implante coclear (IC). A determinação do sucesso do uso do IC é dependente de múltiplos cofatores, entre eles, sugere-se que a presença de audição residual prévia ao implante poderia possibilitar a preservação das vias auditivas e áreas auditivas corticais, proporcionando melhor desenvolvimento das habilidades auditivas e de produção oral da linguagem com o reestabelecimento da entrada sensorial. Objetivo: Verificar a relação entre o PEAEE pré-operatório e a resposta auditiva pós-implante de crianças submetidas ao IC. Casuística e Método: Trata-se de um estudo observacional retrospectivo, desenvolvido a partir da análise de prontuários de pacientes do Hospital das Clínicas da Faculdade de Medicina de Ribeirão Preto, submetidos à cirurgia de IC. Foram incluídas 47 crianças menores de 6 anos à data de realização da cirurgia, diagnosticadas com perda auditiva neurossensorial pré-lingual de grau profundo. Foram coletadas informações audiológicas pré-implantação - PEAEE, PEATE, audiometria comportamental e demais aspectos de caracterização da perda auditiva; a categoria de percepção auditiva e de expressão oral da linguagem antes e após a implantação; além de informações socioeconômicas e da intervenção terapêutica. Resultados: O registro do PEAEE esteve presente em 34 (72,3%) crianças com limiar médio de 89,7 ± 10,2 dB NA na orelha implantada, consideradas as frequências de 0,5; 1; 2 e 4 kHz. A reavaliação foi conduzida em média 7,2 ± 2,1 meses após a cirurgia de IC, quando 23 (49%) sujeitos apresentaram avanço de uma categoria no desenvolvimento da percepção de fala e 4 (8,5%) alcançaram um desempenho dois níveis superior ao da avaliação anterior. O limiar obtido na audiometria em campo com o uso de IC teve média de 44,4 ± 12,4 dB NA, consideradas as frequências de 0,5; 1; 2 e 4 kHz. Quanto à expressão oral da linguagem, 13 (27,6%) crianças tiveram melhora em seu desempenho. Não houve correlação entre os resultados do PEAEE pré-implante e o limiar auditivo (p-valor=0,338) ou a categoria de linguagem (p-valor=0,358) com uso de IC quando controlado pela idade; nem em relação à melhora no desempenho de linguagem oral (p-valor= 0,095). Conclusão: Não houve correlação direta entre o limiar eletrofisiológico mensurado por meio do PEAEE e a resposta auditiva com uso de IC, quando analisados o limiar auditivo comportamental com IC ou a categoria de percepção de fala. / Background: The Auditory Steady State Response (ASSR) is an electrophysiological exam that allows simultaneous and binaural frequency specific testing of hearing thresholds. Considering its objectivity, the test has been recommended for hearing loss diagnosis in young children. This possibility of early identification of hearing impairment is fundamental for minimizing handicaps caused by sensory deprivation and for planning proper intervention, for example, suggesting the use of cochlear implants (CI). The determination of the success of CI prognosis depends on several cofactors. Researchers suggest that residual hearing and hearing thresholds before CI surgery could allow auditory pathways preservation and enable the development of hearing abilities, as well as speech production skills, after the reestablishment of sensory input. Objective: To verify the relation between pre-operatory ASSR and post-CI auditory response in young children. Casuistic and Method: An observational retrospective study was conducted. Medical records were assessed in 47 children, younger than six years old at the CI surgery, diagnosed with sensorineural pre-linguistic hearing loss of profound degree. Information was collected about (a) audiological data - ASSR, ABR, behavioral audiometry, and other hearing loss aspects; (b) category of speech perception and oral language production before and after CI; (c) socioeconomics data and therapy attendance. Results: ASSR record was present in 34 (72.4%) children with mean threshold of 89.7 (10.2 SD) dB HL in the implanted ear, considering the frequencies of 0.5; 1; 2 and 4 kHz. Post-implant evaluation was conducted after a mean of 7.2 (2.1 SD) months of surgery. Then, 23 (49%) subjects enhanced one category of speech perception and four (8.5%) improved two categories, compared to previous evaluation. Field auditory threshold with CI was measure at 44.4 (12.4 SD) dB HL in mean, considering the frequencies of 0.5; 1; 2 and 4 kHz. Analyzing language expression development, 13 (27.6%) children improved their performance. To the age at CI surgery there was no correlation between ASSR thresholds and CI thresholds (p-value=0.338) or speech perception category (p-value=0.358) after CI. No correlation has been found between ASSR and expressive language development (p-value=0.095). Conclusion: There was no direct correlation between electrophysiological thresholds measured by ASSR and hearing response after CI, when analyzed behavioral CI threshold or speech perception.
25

Avaliação da audição residual em candidatos  a implantes coclear atráves da resposta  auditiva de estado estável / Evaluation of residual hearing in cochlear implants candidates using auditory steady-state response

Ramos, Henrique Faria 02 April 2013 (has links)
INTRODUÇÃO: A identificação e preservação da audição residual em candidatos a implante coclear vêm assumindo maior importância clínica. A resposta auditiva de estado estável (RAEE) pode fornecer informação frequência-específica sobre o limiar auditivo em níveis de intensidade máximos de 120 dB NA, possibilitando a investigação da audição residual. Os objetivos deste estudo são avaliar a audição residual em candidatos a implante coclear, comparando os limiares eletrofisiológicos da RAEE com os limiares psicoacústicos da audiometria nas frequências de 500, 1 000, 2 000 e 4 000 Hz. MÉTODO: Foram avaliados 40 candidatos a implante coclear (80 orelhas) com perda auditiva neurossensorial severa a profunda bilateral. A audiometria foi realizada com o tom \"warble\" nas frequências de 500, 1 000, 2 000 e 4 000 Hz com intensidade máxima de estimulação de 120 dB NA. A RAEE foi obtida através da estimulação dicótica de uma frequência de tons contínuos sinusoidais modulados 100% em amplitude exponencial e 20% em frequência, nas frequências portadoras de 500, 1 000, 2 000 e 4 000 Hz, com estimulação máxima de 117, 120, 119 e 118 dB NA, respectivamente. RESULTADOS: Foram obtidos limiares mensuráveis em 62,5% de todas as frequências estudadas na audiometria tonal e em 63,1% na RAEE. A RAEE apresentou sensibilidade de 96% e especificidade de 91,6% na detecção da audição residual. As diferenças médias entre os limiares da audiometria tonal e da RAEE não apresentaram significância estatística em nenhuma das frequências. As correlações entre os limiares comportamentais e da RAEE foram significantes em todas as frequências avaliadas, sendo fortes em 500, 1 000 e 2 000 Hz e moderada em 4 000 Hz, com coeficiente de correlação de Pearson entre 0,65 e 0,81. Em 90% dos casos, os limiares da RAEE foram adquiridos nos limites de 10 dB dos limiares comportamentais. CONCLUSÕES: As correlações entre os limiares tonais e da RAEE foram significantes nas frequências de 500, 1 000, 2 000 e 4 000 Hz. A RAEE apresentou alta sensibilidade e especificidade na detecção da audição residual em candidatos a implante coclear, em comparação com a audiometria tonal / INTRODUCTION: Identification and preservation of residual hearing in cochlear implantation are becoming more important lately. Auditory steadystate response (ASSR) can provide frequency-specific information regarding the auditory thresholds at maximum intensity levels of 120 dB HL, allowing investigation of residual hearing. The study objectives are to assess residual hearing in cochlear implant candidates by comparing the electrophysiological thresholds obtained in ASSR with psychoacoustic thresholds of audiometry at 500, 1 000, 2 000 and 4 000 Hz. METHOD: Forty cochlear implant candidates (80 ears) with bilateral severe-to-profound sensorineural hearing loss were studied. Warble-tone audiometry was performed at the frequencies 500, 1 000, 2 000 e 4 000 Hz, with stimuli up to 120 dB HL. ASSR was obtained with dichotic single-frequency stimulation of sinusoidal continuous tones modulated in exponential amplitude of 100% and in frequency of 20%, at the carrier frequencies of 500, 1 000, 2 000 and 4 000 Hz at maximum stimulation levels of 117, 120, 119 and 118 dB HL, respectively. RESULTS: Thresholds were obtained in 62,5% of all frequencies evaluated in warbletone audiometry and in 63,1% in the ASSR. ASSR showed sensitivity of 96% and specificity of 91,6% in the detection of residual hearing. The mean difference between the thresholds of behavioral audiometry and ASSR were not statistically significant in any of the frequencies. Strong correlations between behavioral and ASSR thresholds were observed in 500, 1 000 and 2 000 Hz and moderate in 4 000 Hz, with Pearson correlation coefficient between 0,65 and 0,81. In 90% of the occasions, ASSR thresholds were within 10 dB of behavioral thresholds. CONCLUSIONS: The correlations between behavioral and ASSR thresholds were significant at 500, 1 000, 2 000 and 4 000 Hz. ASSR showed high sensitivity and specificity in the detection of residual hearing in cochlear implant candidates, compared to warble-tone audiometry
26

Estímulos CE-chirp® e narrow band CE-chirps® na avaliação eletrofisiológica da audição: resultados clínicos em neonatos, lactentes e crianças / CE-chirp® and narrow band CE-chirps® stimuli in electrophysiological assessment of hearing: clinical outcomes in neonates, infants and children

Rodrigues, Gabriela Ribeiro Ivo 24 May 2012 (has links)
Made available in DSpace on 2016-04-27T18:11:56Z (GMT). No. of bitstreams: 1 Gabriela Ribeiro Ivo Rodrigues.pdf: 4015764 bytes, checksum: 07311235963cd8c282288b7d688c3e0f (MD5) Previous issue date: 2012-05-24 / Fundação de Amparo a Pesquisa do Estado de São Paulo / The auditory steady-state response (ASSR) has been suggested as an alternative to the auditory brainstem response (ABR) to estimate the hearing threshold in children who are unable to carry out the tests with conditioned behavioral hearing procedures. The purpose of this study was to verify the applicability of ASSR to estimate the hearing thresholds in children with sensorineural hearing loss, comparing them to other procedures available for this assessment. The study included 15 children ages between 2 months and 3 years old, with sensorineural hearing loss. The ASSR obtained in 1, 2 and 4 kHz were compared with click ABR; the ASSR at 0.5, 1, 2 and 4 kHz were compared with the tone-ABR and with the visual reinforcement audiometry (VRA). The results showed good concordance between the ASSR at high frequencies with the responses of click ABR (0.63 - 0.70), being the best correlation for 1 kHz (0.70). When compared to tone-ABR it could be seen good concordance between the techniques, with coefficients of 0.77, 0.60, 0.66 and 0.50 for the frequencies of 0.5, 1, 2 and 4 kHz. However, the best coefficients were comparing the ASSR with the VRA (0.89 - 0.93), indicating strong correlation between the techniques. The results showed that when compared to other procedures available to estimate the hearing, the ASSR provided similar findings, proving to be a viable technique in order to estimate the hearing thresholds in a child when the VRA may not be possible / Os Potencias Evocados Auditivos de Estado Estável (PEAEE) têm sido apontados como uma alternativa aos Potenciais Evocados Auditivos de Tronco Encefálico (PEATE) para estimar os limiares auditivos em crianças que não conseguem realizar a avaliação auditiva comportamental com procedimentos condicionados. O objetivo deste estudo foi verificar a aplicabilidade dos PEAEE para estimar os limiares auditivos em crianças com perda auditiva neurossensorial, comparando-os os outros procedimentos disponíveis para esta avaliação. Participaram deste estudo 15 crianças com idades entre 2 meses e 3 anos, todas com perda auditiva neurossensorial. As respostas obtidas nos PEAEE nas freqüências de 1, 2 e 4 kHz foram comparadas com as do PEATE-clique; as respostas dos PEAEE nas freqüências de 0.5, 1, 2 e 4 kHz foram comparadas com as dos PEATE por freqüência específica (PEATE-FE) e com a audiometria de reforço visual (VRA). Os resultados encontrados mostraram boas concordâncias entre as respostas dos PEAEE nas altas freqüências e as respostas dos PEATE-clique (0.63 - 0.70), sendo a melhor correlação para a freqüência de 1 kHz (0.70). Quando os PEAEE foram comparados aos PEATE-FE também foram observadas boas concordâncias, com coeficientes de 0.77, 0.60, 0.66 e 0.50 para as freqüências de 0.5, 1, 2 e 4 kHz. Todavia, os melhores coeficientes obtidos foram da comparação dos PEAEE com a VRA (0.89 0.93), indicando forte concordância entre as técnicas. Os resultados mostraram que, quando comparados aos outros procedimentos eletrofisiológicos disponíveis para estimar a audição, os PEAEE forneceram medidas bem semelhantes, assim como quando comparados a VRA; demonstrando ser uma técnica viável para estimar os limiares auditivos de forma objetiva quando a VRA pode não ser possível
27

Avaliação do recesso do nervo facial e cóclea no osso temporal de cadáveres de recém nascidos natimortos com vistas ao implante coclear percutâneo / Evaluation of the facial nerve recess and cochlea on the temporal bones of cadaveric newborns and its applicability in the percutaneous cochlear implant technique

Braga, Gabriela Pereira Bom 23 January 2017 (has links)
INTRODUÇÃO: A literatura evidencia as diferenças anatômicas do osso temporal em crianças quando comparadas à adultos. Mais e mais a literatura enfatiza a importância de que as crianças com surdez congênita devem ser implantadas cada vez mais precocemente. Estudos anátomo-radiológicos são importantes para o desenvolvimento de técnicas cirúrgicas que possibilitem implantar crianças recém natas. Técnicas de implante coclear percutâneo (através de robótica) tem sido desenvolvidas na Universidade de Vanderbilt. Criamos então nossa principal pergunta \"Seria possível implantar crianças recém natas através de implante percutâneo?\" e procuraremos respondê-la no curso desse trabalho. OBJETIVO: Aferir as medidas do recesso do nervo facial e sua relação com a cóclea visando simular o trajeto da broca através desse recesso, para realização da cocleostomia, objetivando o implante coclear percutâneo. CASUÍSTICA E METODOLOGIA: Estudo experimental realizado com 9 espécimes de natimortos com idade gestacional entre 32 e 40 semanas, submetidos à tomografia computadorizada com individualização e reconstrução do nervo facial, cadeia ossicular, membrana timpânica, cóclea e labirinto, seguido da definição da trajetória da broca até a escala timpânica, utilizando o software Improvise. RESULTADOS: As medidas da trajetória da broca até o nervo facial, variaram de 0.58 a mais próxima e, 1.71 a mais distante; quando analisamos os resultados obtidos para cadeia ossicular, temos uma variação que vai de 0.38 até 1.49. A membrana timpânica se encontra entre 0.85 e 1.96 de distância da trajetória simulada da broca. A trajetória da cortical do osso temporal até a escala timpânica, variou de 5.92 a 12.65. CONCLUSÃO: As medidas da relação, entre a broca e as estruturas anatômicas da orelha média e, a simulação da trajetória, mostraram que é possível executar com segurança a técnica de implante coclear percutâneo em crianças a partir de 32 semanas de gestação / INTRODUCTION: Literature shows changes in the temporal bone anatomy in children when compared with adults. More and more literature emphasizes the importance of children with congenital deafness should be implanted increasingly early. Anatomical radiologic studies are important for the development of surgical techniques that allow implanting new born. Percutaneous cochlear implant technique (through robotics) was developed in Vanderbilt University. So we created our main question \" Is it possible to implant new born children using the percutaneous technique? \" and we\'ll try to answer it in the course of this work. PATIENTS AND METHODS: Experimental study done in 9 stillbirth specimens with 32 and 40 weeks of age, submitted to CT study followed by reconstruction of the facial nerve, ossicular chain, tympanic membrane, labyrinth and cochlea. The CT evaluation and reconstruction was done with Improvise software, also used for measurements of the distances and in the simulation of the drill\'s trajectory (mm). RESULTS: The drill trajectory measurements to the facial nerve, ranged from 0.58 the nearest and the farthest 1.71, when we analyzed the results for ossicular chain, we have a range that goes from 0.38 to 1.49. The tympanic membrane is between 0.85 and 1.96 away from the simulated drill path. Cortical trajectory of the temporal bone to the scala tympani, ranged from 5.92 to 12.65. CONCLUSION: The measures of the relationship between the drill and the anatomical structures of the middle ear and the simulated trajectory, showed that it is possible to use safely the percutaneous cochlear implant technique in children of 32 weeks/old
28

Avaliação da audição residual em candidatos  a implantes coclear atráves da resposta  auditiva de estado estável / Evaluation of residual hearing in cochlear implants candidates using auditory steady-state response

Henrique Faria Ramos 02 April 2013 (has links)
INTRODUÇÃO: A identificação e preservação da audição residual em candidatos a implante coclear vêm assumindo maior importância clínica. A resposta auditiva de estado estável (RAEE) pode fornecer informação frequência-específica sobre o limiar auditivo em níveis de intensidade máximos de 120 dB NA, possibilitando a investigação da audição residual. Os objetivos deste estudo são avaliar a audição residual em candidatos a implante coclear, comparando os limiares eletrofisiológicos da RAEE com os limiares psicoacústicos da audiometria nas frequências de 500, 1 000, 2 000 e 4 000 Hz. MÉTODO: Foram avaliados 40 candidatos a implante coclear (80 orelhas) com perda auditiva neurossensorial severa a profunda bilateral. A audiometria foi realizada com o tom \"warble\" nas frequências de 500, 1 000, 2 000 e 4 000 Hz com intensidade máxima de estimulação de 120 dB NA. A RAEE foi obtida através da estimulação dicótica de uma frequência de tons contínuos sinusoidais modulados 100% em amplitude exponencial e 20% em frequência, nas frequências portadoras de 500, 1 000, 2 000 e 4 000 Hz, com estimulação máxima de 117, 120, 119 e 118 dB NA, respectivamente. RESULTADOS: Foram obtidos limiares mensuráveis em 62,5% de todas as frequências estudadas na audiometria tonal e em 63,1% na RAEE. A RAEE apresentou sensibilidade de 96% e especificidade de 91,6% na detecção da audição residual. As diferenças médias entre os limiares da audiometria tonal e da RAEE não apresentaram significância estatística em nenhuma das frequências. As correlações entre os limiares comportamentais e da RAEE foram significantes em todas as frequências avaliadas, sendo fortes em 500, 1 000 e 2 000 Hz e moderada em 4 000 Hz, com coeficiente de correlação de Pearson entre 0,65 e 0,81. Em 90% dos casos, os limiares da RAEE foram adquiridos nos limites de 10 dB dos limiares comportamentais. CONCLUSÕES: As correlações entre os limiares tonais e da RAEE foram significantes nas frequências de 500, 1 000, 2 000 e 4 000 Hz. A RAEE apresentou alta sensibilidade e especificidade na detecção da audição residual em candidatos a implante coclear, em comparação com a audiometria tonal / INTRODUCTION: Identification and preservation of residual hearing in cochlear implantation are becoming more important lately. Auditory steadystate response (ASSR) can provide frequency-specific information regarding the auditory thresholds at maximum intensity levels of 120 dB HL, allowing investigation of residual hearing. The study objectives are to assess residual hearing in cochlear implant candidates by comparing the electrophysiological thresholds obtained in ASSR with psychoacoustic thresholds of audiometry at 500, 1 000, 2 000 and 4 000 Hz. METHOD: Forty cochlear implant candidates (80 ears) with bilateral severe-to-profound sensorineural hearing loss were studied. Warble-tone audiometry was performed at the frequencies 500, 1 000, 2 000 e 4 000 Hz, with stimuli up to 120 dB HL. ASSR was obtained with dichotic single-frequency stimulation of sinusoidal continuous tones modulated in exponential amplitude of 100% and in frequency of 20%, at the carrier frequencies of 500, 1 000, 2 000 and 4 000 Hz at maximum stimulation levels of 117, 120, 119 and 118 dB HL, respectively. RESULTS: Thresholds were obtained in 62,5% of all frequencies evaluated in warbletone audiometry and in 63,1% in the ASSR. ASSR showed sensitivity of 96% and specificity of 91,6% in the detection of residual hearing. The mean difference between the thresholds of behavioral audiometry and ASSR were not statistically significant in any of the frequencies. Strong correlations between behavioral and ASSR thresholds were observed in 500, 1 000 and 2 000 Hz and moderate in 4 000 Hz, with Pearson correlation coefficient between 0,65 and 0,81. In 90% of the occasions, ASSR thresholds were within 10 dB of behavioral thresholds. CONCLUSIONS: The correlations between behavioral and ASSR thresholds were significant at 500, 1 000, 2 000 and 4 000 Hz. ASSR showed high sensitivity and specificity in the detection of residual hearing in cochlear implant candidates, compared to warble-tone audiometry
29

Avaliação do recesso do nervo facial e cóclea no osso temporal de cadáveres de recém nascidos natimortos com vistas ao implante coclear percutâneo / Evaluation of the facial nerve recess and cochlea on the temporal bones of cadaveric newborns and its applicability in the percutaneous cochlear implant technique

Gabriela Pereira Bom Braga 23 January 2017 (has links)
INTRODUÇÃO: A literatura evidencia as diferenças anatômicas do osso temporal em crianças quando comparadas à adultos. Mais e mais a literatura enfatiza a importância de que as crianças com surdez congênita devem ser implantadas cada vez mais precocemente. Estudos anátomo-radiológicos são importantes para o desenvolvimento de técnicas cirúrgicas que possibilitem implantar crianças recém natas. Técnicas de implante coclear percutâneo (através de robótica) tem sido desenvolvidas na Universidade de Vanderbilt. Criamos então nossa principal pergunta \"Seria possível implantar crianças recém natas através de implante percutâneo?\" e procuraremos respondê-la no curso desse trabalho. OBJETIVO: Aferir as medidas do recesso do nervo facial e sua relação com a cóclea visando simular o trajeto da broca através desse recesso, para realização da cocleostomia, objetivando o implante coclear percutâneo. CASUÍSTICA E METODOLOGIA: Estudo experimental realizado com 9 espécimes de natimortos com idade gestacional entre 32 e 40 semanas, submetidos à tomografia computadorizada com individualização e reconstrução do nervo facial, cadeia ossicular, membrana timpânica, cóclea e labirinto, seguido da definição da trajetória da broca até a escala timpânica, utilizando o software Improvise. RESULTADOS: As medidas da trajetória da broca até o nervo facial, variaram de 0.58 a mais próxima e, 1.71 a mais distante; quando analisamos os resultados obtidos para cadeia ossicular, temos uma variação que vai de 0.38 até 1.49. A membrana timpânica se encontra entre 0.85 e 1.96 de distância da trajetória simulada da broca. A trajetória da cortical do osso temporal até a escala timpânica, variou de 5.92 a 12.65. CONCLUSÃO: As medidas da relação, entre a broca e as estruturas anatômicas da orelha média e, a simulação da trajetória, mostraram que é possível executar com segurança a técnica de implante coclear percutâneo em crianças a partir de 32 semanas de gestação / INTRODUCTION: Literature shows changes in the temporal bone anatomy in children when compared with adults. More and more literature emphasizes the importance of children with congenital deafness should be implanted increasingly early. Anatomical radiologic studies are important for the development of surgical techniques that allow implanting new born. Percutaneous cochlear implant technique (through robotics) was developed in Vanderbilt University. So we created our main question \" Is it possible to implant new born children using the percutaneous technique? \" and we\'ll try to answer it in the course of this work. PATIENTS AND METHODS: Experimental study done in 9 stillbirth specimens with 32 and 40 weeks of age, submitted to CT study followed by reconstruction of the facial nerve, ossicular chain, tympanic membrane, labyrinth and cochlea. The CT evaluation and reconstruction was done with Improvise software, also used for measurements of the distances and in the simulation of the drill\'s trajectory (mm). RESULTS: The drill trajectory measurements to the facial nerve, ranged from 0.58 the nearest and the farthest 1.71, when we analyzed the results for ossicular chain, we have a range that goes from 0.38 to 1.49. The tympanic membrane is between 0.85 and 1.96 away from the simulated drill path. Cortical trajectory of the temporal bone to the scala tympani, ranged from 5.92 to 12.65. CONCLUSION: The measures of the relationship between the drill and the anatomical structures of the middle ear and the simulated trajectory, showed that it is possible to use safely the percutaneous cochlear implant technique in children of 32 weeks/old
30

INTERFERÊNCIA BINAURAL E ADAPTAÇÃO DE PRÓTESES AUDITIVAS EM PERDAS AUDITIVAS SIMÉTRICAS / BINAURAL INTERFERENCE AND ADAPTATION TO HEARING AIDS INSYMMETRICAL HEARING LOSS

Azevedo, Milena Manoel de 18 September 2013 (has links)
Purpose: To investigate the occurrence of binaural interference. To investigate the mono or binaural use of hearing aids and the complaints of speech comprehension in silence and noise.To evaluate the speech recognition with and without the use of mono and binaural hearing aids and the auditory processing skills.To correlate the obtained results in different tests. To evaluate the recognition of sentences in silence and noise by elderly individuals with symmetrical hearing loss, users of hearing aids with mono and binaural adaptation, and to investigate in which of both situations it may be verified the best performance in conditions that simulate daily communication situations. Material and Method: The evaluated subjects were 25 men and 13 women, with ages between 60 and 89 years old, with sensorineural hearing loss from mild to moderate severe level, symmetrical configuration, users of hearing aids with binaural indication. It was researched the Percentage Index of Speech Recognition (PISR) in both ears (BE) and it was performed the Dichotic Digits Test (DDT) of divided and directed attention, and the Portuguese Sentence List test (PSL). It was also studied the sentence recognition threshold in quiet (SRTQ) and in noise (SRTN) and the percentual indexes of sentence recognition in quiet environment and under noise (PISRQ and PISRN), with binaural adaptation (BA) and monaural in the right ear (RE) and in the left ear (LE). Results: Among the evaluated individuals, 31 (81.58%) referred that they use binaural hearing aids, 19 subjects (50%) reported they have never had difficulties to understand speech in silent places and 17 (44.75%) answered sometimes. 22 (57.89%) referred difficulties to recognize speech in noisy places, sometimes and 15 (39.47%) said it always happened. The obtained average values for the PISR were 72.95% in BE, 59.26% in the RE and 60.53% in the LE, respectively. The obtained averages in the DDT were 54.58% in BE, 65.16% in the RE and 71.95% in the LE. Regarding the PISRQ data, they were 79.63% in BE, 74.79% in the RE and 72.40% in the LE. The correlation of the PISR, DDT and PISRQ, the PISR and the PSL tend to present similar values. About analyzes into silence and into noise with binaural and monaural adaptation, the average values for PISRQ were 80.89% in BE, 76.33% in the RE and 71.16% in the LE, respectively. The obtained averages for PISRN were 62.05% in BE, 60.52% in the RE and 60.33% in the LE. Conclusion: It was found in an individual, the presence of binaural interference. Most elderly people used binaural hearing aids; only one individual did not present complaints of speech comprehension into noise. The PISR showed better performance in binaural condition; the DDT may not be the most proper option to be used in elderly patients with hearing loss; the PISR and the PSL tend to present similar values. The sentence recognition by the evaluated subjects presented better performance with the binaural adaptation, as into silence as into noise. However, that difference was not statistically significant. / Objetivo:Investigar a ocorrência da interferência binaural. Investigar o uso mono ou binaural das próteses auditivas e as queixas de compreensão de fala no silêncio e no ruído. Avaliar o reconhecimento de fala com e sem uso de próteses auditivas mono e binaural e habilidades do processamento auditivo. Correlacionar os resultados obtidos nos diferentes testes. Avaliar o reconhecimento de sentenças no silêncio e no ruído, de indivíduos idosos com perdas auditivas simétricas, usuários de próteses auditivas com adaptação mono e binaural, investigando em qual das duas situações pode ser verificado o melhor desempenho em condições que simulam situações de comunicação do diaadia. Material e método: Foram avaliados 38 sujeitos, sendo 25 homens e 13 mulheres, com idade entre 60 e 89 anos, perda auditiva neurossensorial de grau leve a moderadamente severo, de configuração simétrica, usuários de próteses auditivascom indicação binaural. Foi pesquisado o Índice Percentual de Reconhecimento de Fala (IPRF) em ambas as orelhas (AO) e realizados dois testes: oTeste Dicótico de Dígitos (TDD) atenção dividida e direcionada e o teste Listas de Sentenças em Português (LSP). Pesquisou-se aindaos Limiares de Reconhecimento de Sentenças no Silêncio e no Ruído (LRSS e LRSR) e Índice Percentual de Reconhecimento de Sentenças no Silêncio e no ruído (IPRSS e IPRSR), com adaptação binaural (AO) e monoaural orelha direita (OD) e orelha esquerda (OE). Resultados:Entre os indivíduos avaliados, 31(81,58%) relataram fazer uso binaural das próteses auditivas, 19 (50%) relataram nunca ter dificuldade de compreender a fala no silêncio e 17(44,75%) às vezes. 22 (57,89%) referiram dificuldade para reconhecer a fala no ruído, às vezes e 15 (39,47%) sempre. Os valores médios obtidos para os IPRF foram de 72,95% em AO, 59,26% na OD e 60,53% na OE, respectivamente. As médias obtidas do TDD foram 54,58% em AO, 65,16% na OD e 71,95% OE. Quanto aos dados do IPRSS, foram de 79,63% em AO, 74,79% na OD e 72,40% na OE. A correlação das variáveis IPRF, TDD e IPRSS, o IPRF e o LSP tendem a apresentar resultados semelhantes. Em relação às análises no silêncio e no ruído com adaptação binaural e monoaural, os valores médios obtidos para os IPRSS foram de 80,89% em AO, 76,33% na OD e 71,16% na OE, respectivamente. Já as médias obtidas do IPRSR foram 62,05 % em AO, 60,52% na OD e 60,33%OE. Conclusão:Foi encontrado em um indivíduo indícios da presença de interferência binaural. A grande maioria dos idosos fazia uso binaural das próteses auditivas.Somente um indivíduo não apresentou queixa de compreensão de fala no ruído. O IPRF demonstrou melhor desempenho na condição binaural. O TDD evidenciou pior desempenho na tarefa de integração binaural. Já no LSP não foi encontrada diferença estatisticamente significante entre o desempenho mono e binaural. O teste TDD pode não ser a opção mais adequada para ser utilizado em pacientes idosos com perda auditiva; já o IPRF e o LSP tendem a apresentar resultados semelhantes. O reconhecimento de sentenças dos sujeitos avaliados mostrou melhor desempenho com a adaptação binaural, tanto no silêncio como no ruído. Entretanto, essa diferença não foi estatisticamente significante.

Page generated in 0.0807 seconds