Spelling suggestions: "subject:"odontologica"" "subject:"odontologia""
31 |
An?lise mec?nica e microestrutural das ligas de cobalto-cromo de uso odontol?gico ap?s sucessivas refundi??esDantas, H?rrisson de Almeida 30 May 2008 (has links)
Made available in DSpace on 2014-12-17T14:07:01Z (GMT). No. of bitstreams: 1
HarrisonAD.pdf: 3488100 bytes, checksum: 805801db06d21e5667735d16a5799fe2 (MD5)
Previous issue date: 2008-05-30 / The cobalt-chromium alloy is extensively used in the Odontology for the confection of metallic scaffolding in partial removable denture. During the last few years, it has been reported an increasing number of premature imperfections, with a few months of prosthesis use. The manufacture of these components is made in prosthetic laboratories and normally involves recasting, using parts of casting alloy
and parts of virgin alloy. Therefore, the objective of the present study was to analyze the mechanical properties of a commercial cobalt-chromium alloy of odontological
use after successive recasting, searching information to guide the dental prosthesis laboratories in the correct manipulation of the cobalt-chromium alloy in the process of casting and the possible limits of recasting in the mechanical properties of this material. Seven sample groups were confectioned, each one containing five test bodies, divided in the following way: G1: casting only with virgin alloy; G2: casting with 50% of the alloy of the G1 + 50% of virgin alloy; G3: casting with 50% of the alloy of the G2 + 50% of virgin alloy; G4: casting with 50% of the alloy of the G3 + 50% of virgin alloy; G5: 50% of alloy of the G4 + 50% of virgin alloy; G6: 50% of alloy
of the G5 + 50% of virgin alloy and finally the G7, only with recasting alloy. The modifications in the mechanical behavior of the alloy were evaluated. Moreover, it was carried the micro structural characterization of the material by optic and
electronic scanning microscopy, and X ray diffraction.and fluorescence looking into the correlatation of the mechanical alterations with structural modifications of the material caused by successive recasting process. Generally the results showed alterations in the fracture energy of the alloy after successive recasting, resulting mainly of the increasing presence of pores and large voids, characteristic of the
casting material. Thus, the interpretation of the results showed that the material did not reveal significant differences with respect to the tensile strength or elastic limit,
as a function of successive recasting. The elastic modulus increased from the third recasting cycle on, indicating that the material can be recast only twice. The fracture
energy of the material decreased, as the number of recasting cycles increased. With respect to the microhardness, the statistical analyses showedno significant differences. Electronic scanning microscopy revealed the presence of imperfections and defects, resulting of the recasting process. X ray diffraction and fluorescence did not show alterations in the composition of the alloy or the formation of crystalline
phases between the analyzed groups. The optical micrographs showed an increasing number of voids and porosity as the material was recast. Therefore, the general conclusion of this study is that the successive recasting of of Co-Cr alloys affects the mechanical properties of the material, consequently leading to the failure of the prosthetic work. Based on the results, the best recommendadition is that the use of the material should be limited to two recasting cycles / Ligas cobalto-cromo s?o extensivamente utilizadas na Odontologia para a confec??o de arma??es met?licas em pr?teses parciais remov?veis. Durante os ?ltimos anos, tem sido reportado um n?mero crescente de falhas prematuras, com poucos meses de utiliza??o das pr?teses. A fabrica??o desses componentes ? feita em laborat?rios prot?ticos e normalmente envolve a refundi??o, utilizando partes de
liga fundida e partes de liga virgem. Portanto, o objetivo do presente estudo foi analisar as propriedades mec?nicas de uma liga comercial de cobalto-cromo de uso odontol?gico ap?s sucessivas refundi??es, buscando informa??es no sentido de orientar os laborat?rios de pr?tese dent?ria na correta manipula??o dessa liga no processo de fundi??o e nos poss?veis limites de refundi??o desse material. Foram
confeccionados sete grupos de amostras, cada um contendo cinco corpos de prova, divididos da seguinte maneira: G1: fundi??o apenas com liga virgem; G2: fundi??o com 50% da liga do G1 + 50% de liga virgem; G3: fundi??o com 50% da liga do G2 + 50% de liga virgem; G4: fundi??o com 50% da liga do G3 + 50% de liga virgem; G5: 50% de liga do G4 + 50% de liga virgem; G6: 50% de liga do G5 + 50% de liga
virgem e finalmente o G7, s? com liga refundida. Foram avaliadas as principais modifica??es ocorridas no comportamento mec?nico dessa liga por meio de ensaios
de tra??o e microdureza. Al?m disso, foi realizada a caracteriza??o microestrutural do material por meio de microscopia ?ptica e eletr?nica de varredura, difra??o e
fluoresc?ncia de raios X procurando correlacionar as altera??es mec?nicas com modifica??es estruturais do material ocasionadas pelos sucessivos processos de
refundi??o. De forma geral os resultados mostraram altera??es na plasticidade e energia de fratura da liga ap?s sucessivas refundi??es, decorrentes principalmente
da crescente presen?a de poros e vazios, defeitos caracter?sticos da fundi??o do material. A interpreta??o dos resultados permitiu concluir que o material n?o apresentou diferen?as significativas em rela??o ? resist?ncia ? tra??o ou ao limite el?stico, em fun??o das sucessivas refundi??es. A energia de fratura do material mostrou tend?ncia ? diminui??o, ? medida que o material foi refundido. Em rela??o ?
microdureza, as an?lises estat?sticas mostraram n?o haver diferen?as significativas. A microscopia eletr?nica revelou a presen?a de falhas e defeitos, resultantes dos processos de refundi??es. A an?lise por fluoresc?ncia e difra??o de raios X n?o mostrou altera??es na composi??o da liga ou na forma??o de fases cristalinas entre os grupos analisados. As micrografias ?pticas mostraram um crescente n?mero de
vazios e aumento da porosidade ? medida que o material foi refundido. Assim, a conclus?o geral do trabalho ? que as sucessivas refundi??es em ligas de Co-Cr comprometem as propriedades mec?nicas do material, o que pode levar a falhas e consequentemente, ao fracasso do trabalho prot?tico. Com base nos resultados, o mais recomendado ? a utiliza??o de no m?ximo duas refundi??es, para que as propriedades do material n?o sejam comprometidas
|
32 |
A percepção da qualidade de serviços odontológicos segundo cirurgiões-dentistas e pacientes de clínicas odontológicas de Florianópolis / The quality perception of odontological services according to surgeonsdentists and patients in odontological clinics of the city of FlorianópolisPizzato, Márcia Buaes 07 April 2008 (has links)
Made available in DSpace on 2016-12-01T19:18:45Z (GMT). No. of bitstreams: 1
1 capa cap1 e2.pdf: 202961 bytes, checksum: 8c01f713b00fbe91a660b669b03ddd92 (MD5)
Previous issue date: 2008-04-07 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The great number of odontological clinics and professionals of the area in Florianópolis comes demanding for a competition irritation in the odontological service rendering. This competition increase requires an improvement in the quality and in the installment of the odontological services. With sights to analyze the quality according to surgeons-dentists and patients perception of odontological clinics of this municipal district, it took by reference a similar study accomplished by Urdan (2001). when identifying the perceptions, the research allowed to verify the lacunas existence in the installment of the odontological services and the development of a strategic model of quality. The quality attributes were divided into three great subgroups: Attributes related to surgeon-dentist, attributes related to receptionists and attributes linked to the clinics services scenaries, all with a scale of five levels. It is a rising research, descriptive and exploratory. The sample selected comprehended 75 odontological clinics of the municipal district of Florianópolis, and 150 surgeons-dentists and 402 patients answered to the questionnaire semi-structured presented. In function of the collected data to noticed itself that most services quality attributes for the surgeons-dentists highlighted the indispensable and important degrees, being only an identified attribute as little important, while for the patients only the indispensable and important scales represented. The most important attributes for the surgeons-dentists were dentist treat with respect, listen the patient and environment of the organized and clean clinic. It stands out, for the patients, the clinic environment being organized and cleaned, dentist inspire total confidence and dentist listen the patient. The final table allowed still to identify perception similarity between surgeon-dentist and patients in eight new attributes suggested by the searched in the opened questions. The research results remit the importance of considering patients' perception as improvement condition for the quality of the odontological services of Florianópolis / O grande número de clínicas odontológicas e profissionais da área em Florianópolis vem demandando por um acirramento da concorrência na prestação de serviço odontológico. Este aumento da concorrência requer uma melhoria na qualidade e na prestação dos serviços odontológicos. Com vistas a analisar a percepção da qualidade segundo cirurgiões-dentistas e pacientes de clínicas odontológicas deste município, tomou-se por referência um estudo análogo realizado por Urdan (2001). Ao identificar as percepções, a pesquisa permitiu verificar a existência de lacunas na prestação dos serviços odontológicos e o desenvolvimento de um modelo estratégico de qualidade. Os atributos da qualidade foram divididos em três grandes subgrupos: atributos relacionados ao cirurgião-dentista, atributos relacionados às recepcionistas e atributos ligados aos cenários de serviços das clínicas, todos com uma escala de cinco níveis. Trata-se de uma pesquisa de levantamento, descritiva e exploratória. A amostra selecionada compreendeu 75 clínicas odontológicas do município de Florianópolis, sendo que 150 cirurgiões-dentistas e 402 pacientes responderam ao questionário semi-estruturado apresentado. Em função dos dados coletados percebeu-se que a maioria dos atributos de qualidade de serviços para os cirurgiões-dentistas destacavam os graus indispensável e importante, sendo apenas um atributo identificado como pouco importante, ao passo que para os pacientes apenas as escalas indispensável e importante figuraram. Os atributos mais relevantes para os cirurgiões-dentistas foram dentista tratar com respeito, ouvir o paciente e ambiente da clínica organizado e limpo. Destaca-se, para os pacientes, o ambiente da clínica ser organizado e limpo, dentista inspirar total confiança e dentista ouvir o paciente. A tabulação final permitiu ainda identificar similaridade de percepção entre cirurgião-dentista e pacientes em oito novos atributos sugeridos pelos pesquisados nas questões abertas. Os resultados da pesquisa remetem a importância de considerar a percepção dos pacientes como condição de melhoria para a qualidade dos serviços odontológicos de Florianópolis
|
33 |
Estudo das ligas tit?nio-zirc?nio resultantes do processo de fundi??o plasma-skull para aplica??es como biomateriaisMontenegro, Ieda Nadja Silva 06 July 2007 (has links)
Made available in DSpace on 2014-12-17T15:42:01Z (GMT). No. of bitstreams: 1
IedaNSM.pdf: 5948604 bytes, checksum: dbf245a349dd04cff535e8ba2e89601d (MD5)
Previous issue date: 2007-07-06 / The aim of this work was to study a series of 11 different compositions of Ti-Zr binary alloys resistance to aggressive environment, i. e., their ability to keep their surface properties and mass when exposed to them as a way to evaluate their performance as biomaterials. The first stage was devoted to the fabrication of tablets from these alloys by Plasma-Skull casting method using a Discovery Plasma machine from EDG Equipamentos, Brazil. In a second stage, the chemical composition of each produced tablet was verified. In a third stage, the specimen were submitted to: as-cast microstructure analysis via optical and scanning electron microscopy (OM and SEM), x-ray dispersive system (EDS) chemical analysis via SEM, Vickers hardness tests for mechanical evaluation and corrosion resistence tests in a 0.9% NaCl solution to simulate exposition to human saliva monitored by open circuit potential and polarization curves. From the obtained results, it was possible to infer that specimens A1 (94,07 wt% Ti and 5,93% wt% Zr), A4 (77,81 wt % Ti and 22,19 wt % Zr) and A8 (27,83 wt% Ti and 72,17 wt% Zr), presented best performance regarding to corrosion resistance, homogeneity and hardness which are necessary issues for biomaterials to be applied as orthopedic and odontological prosthesis / Este trabalho teve como finalidade estudar uma s?rie de onze ligas met?licas bin?rias, tit?nio zirc?nio, quanto ? capacidade de resistirem ?s deteriora??es sem sofrerem modifica??es de suas propriedades iniciais de massa e superf?cie quando expostas a meios agressivos, como condi??o fundamental para que as mesmas sejam aplicadas como biomateriais. A primeira etapa tratou da confec??o das amostras das ligas em forma de pastilhas, empregando-se o processo de fundi??o Plasma Skull realizado na m?quina Discovery Plasma, produzida no Brasil pela EDG Equipamentos. Na segunda etapa, as amostras confeccionadas foram submetidas aos ensaios para a determina??o da composi??o qu?mica resultante de cada liga da s?rie ap?s a fus?o. E durante a terceira etapa foram feitos os procedimentos de avalia??es das amostras quanto ? homogeneidade e
apresenta??o da microestrutura de cada uma das ligas no estado bruto de fus?o, como resultados dos ensaios metalogr?ficos por microscopia ?ptica e microscopia
eletr?nica de varredura acoplada a espectroscopia por energia dispersiva de raios-x; quanto ? propriedade mec?nica de dureza medida em escala Vickers (HV); e quanto ?s propriedades qu?micas de resist?ncia ? corros?o, quando expostas em solu??o de cloreto de s?dio 0,9 %, para simular a saliva, empregando-se o monitoramento do potencial de circuito aberto e as curvas de polariza??o. A partir dos resultados obtidos foi poss?vel identificar as pastilhas de composi??es qu?micas A1 (94,07% de Ti e 5,93% de Zr), A4 (77,81% de Ti e 22,19% de Zr) e A8 (27,83% de Ti e 72,17% de Zr) que resultaram como maiores detentoras do conjunto de propriedades de resist?ncia ? corros?o, homogeneidade e dureza, as quais s?o mais necess?rias em biomateriais tipo pr?teses ortop?dicas ou odontol?gicas
|
Page generated in 0.0551 seconds