• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 6
  • Tagged with
  • 6
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Parallell beräkning av omslutande volymer / Parallel Computation of Bounding Volumes

Winberg, Olov, Karlsson, Mattias January 2010 (has links)
<p>This paper presents techniques for speeding up commonly used algorithms forbounding volume (BV) computation, such as the AABB, sphere and k-DOP. Byexploiting the possibilities of parallelismin modern processors, the result exceedsthe expected theoretical result. The methods focus on data-level-parallelism(DLP) using Intel’s SSE instructions, for operations on 4 parallel independentsingle precision floating point values, with a theoretical speed-up factor of 4 ondata throughput. Still, a speed-up between 7–9 are shown in the computation ofAABBs and k-DOPs. For the computation of tight fitting spheres the speed-upfactor halts at approximately 4 due to a limiting data dependency. In addition,further parallelization by multithreading algorithms on multi-core CPUs showsspeed-up factors of 14 on 2 cores and reaching 25 on 4 cores, compared to nonparallel algorithms.</p>
2

Parallell beräkning av omslutande volymer / Parallel Computation of Bounding Volumes

Winberg, Olov, Karlsson, Mattias January 2010 (has links)
This paper presents techniques for speeding up commonly used algorithms forbounding volume (BV) computation, such as the AABB, sphere and k-DOP. Byexploiting the possibilities of parallelismin modern processors, the result exceedsthe expected theoretical result. The methods focus on data-level-parallelism(DLP) using Intel’s SSE instructions, for operations on 4 parallel independentsingle precision floating point values, with a theoretical speed-up factor of 4 ondata throughput. Still, a speed-up between 7–9 are shown in the computation ofAABBs and k-DOPs. For the computation of tight fitting spheres the speed-upfactor halts at approximately 4 due to a limiting data dependency. In addition,further parallelization by multithreading algorithms on multi-core CPUs showsspeed-up factors of 14 on 2 cores and reaching 25 on 4 cores, compared to nonparallel algorithms.
3

Den andra verkligheten : En teoretisk studie i jämförelsen mellan Virtual Reality och verklighet / The other reality : A theoretical study of ”virtual” vs. ”real” reality

Klangeryd, Malin January 2010 (has links)
Frågan om verkligheten och dess beskaffenhet har länge orsakat stor förbryllning hos människan, vilken historiskt sett har försökt förklarats på olika sätt. Inte minst genom olika slags gudaläror. Idag lever vi helt annorlunda än vad vi gjorde för exempelvis 1000 år sedan. Det är inte längre gudar som är den dominerande verkligheten – det är IT-tekniken. Idag lever alltfler människor i virtuella världar, så kallade Virtual Realities, som en stor del i deras liv. Så vad är verkligheten? Kan en virtuell verklighet vara verklig? Med dessa frågor i bakgrunden, och genom att applicera ett vardagssociologiskt perspektiv på forskningsresultat inom Virtual Reality, prövar denna uppsats synen av vad som är verkligt eller inte. / Projekt Visualisering
4

MÄTNING AV LUFTTÄTHET I FLERBOSTADSHUS : <em>Gällande krav, praktiskt genomförda mätningar samt en tillämpbar metod</em>

Sörensen, Ida January 2009 (has links)
<p>Stor förvirring råder kring hur lufttätheten ska mätas i flerbostadshus. De metoder som finns och de resultat som erhålls vid täthetsprovning av småhus är inte alltid applicerbara på flerbostadshus även om mätenheterna är de samma. Detta föranleder problemställningen för detta examensarbete:</p><p><em>Varför och hur kontrolleras lufttätheten i ett flerbostadshus på ett praktiskt tillämpbart sätt, som också gör det möjligt att jämföra resultat från olika objekt?</em></p><p>Metoderna som används för att undersöka detta är litteraturstudier och samtal med erfarna personer, samt demonstration av en mätmetod i fullskala. En diskussion med initiativtagarna till detta examensarbete leder fram till en rekommenderad metod och en mall för hur detta ska utföras.</p><p>Byggnadsskalets luft-, diffusions- och vindtätning har stor betydelse för en byggnads energianvändning, fuktsäkerhet, termiska komfort och hygien, luftkvalitet, ljudmiljö, spridning av brand samt spridning av luftföroreningar utifrån och in. Lufttätheten är en avgörande faktor både för konstruktionens beständighet och för en god innemiljö i moderna byggnader. Lufttäta hus är dessutom lönsamma i längden för de inblandade aktörerna. På lång sikt även för miljön. Studier som gjorts visar att en byggnads energiåtgång för uppvärmning minskar med nästan 30 % om lufttätheten (egentligen luftgenomsläppligheten) förbättras från 0,8 l/s·m<sup>2</sup> till 0,4 l/s·m<sup>2</sup>. En så stor minskning av energianvändningen kunde inte åstadkommas med andra energiförbättringsåtgärder som undersöktes.</p><p>I Boverkets Regelsamling för byggande, BBR 2008 har kravet på lufttäthet tagits bort till förmån för ett funktionskrav för energianvändningen, under vilken lufttätheten faller in. Regelsamlingens allmänna råd hänvisar till standarden, SS-EN 13829 för bestämning av luftläckage.</p><p>De metoder som idag finns att tillgå för att mäta lufttätheten hos byggnader är spårgasmetoden, täthetsprovning med provisorisk vägg, det egna ventilationssystemet, med mottryck i angränsande utrymmen samt med tryckdörr. Den sistnämnda metoden provades på flerbostadshus i Umeå med goda resultat.</p><p>Observera att resultatet för denna rapport är en mall för mätningsförfarandet och den rekommenderade metoden för att mäta lufttäthet inom NCC i Umeå. Den beskriver en praktiskt tillämpbar metod där resultatet går att jämföra mellan olika objekt. Även en intern mätstorhet som beskriver ytterväggens täthet är framtagen.</p><p>Mätstorheten och standardens relevans diskuteras. Ändringen i BBR från specificerade krav till funktionskrav anses vara kunskapsdrivande. Det förfarande som beskrivs i resultatet har bedömts vara det mest optimala under rådande förhållanden med den standard som finns. En förändring av standarden skulle kunna leda till en bättre metod som ger mer informativt resultat.</p> / <p>There is a great perplexity about how air permeability should be measured in multiple-unit dwellings. The methods available and the obtained results for determination of air permeability in single-dwelling houses are not applicable for multiple-unit dwellings, even if the derived quantities are the same. This causes the problem for this report:</p><p><em>Why and how should the air permeability be determined for a multiple-unit dwelling in a functional and applicable way, which also makes it possible to compare the obtained results from different dwelling units?</em></p><p>The methods used to explore solutions are literature studies, conversation with professionals and a full-scale demonstration of one of the methods. A discussion with the initiators of this report leads to the recommended method and a model for how it should be performed.</p><p>The air-, diffusion- and windtightness of the building envelope are of big importance to the building. The use of energy, moisture transfer, thermal comfort and hygiene, air quality, noise, spreading of fire and spreading of air pollutions are all affected by it. The air tightness is a crucial element for the durability of the building and to secure a good indoor environment. Air tight buildings are also cost-effective in the long run for the involved participants. They are also good for the environment. A study that have been made show that the energy-use for heating buildings will be reduced with almost 30 % if the air permeability improves from 0,8 l/s·m<sup>2</sup> to 0,4 l/s·m<sup>2</sup>. Such a big reduction of the energy use could not be accomplished with any other energy improvement-move that was investigated in the study.</p><p>The Swedish building regulations, Boverkets Regelsamling för byggande BBR, used to have a demand for the air tightness of buildings. It has been removed in favor of a demand of the function for the energy use, which also include the air tightness. The common advices in BBR refer to the standard, SS-EN 13829 for determination of air permeability.</p><p>The methods available for determination of air permeability in buildings are the tracer-gas method, determination with a temporary wall, the ventilation system, with corresponding pressure in adjacent spaces and determination with a Blower Door. The last method was demonstrated in multiple-unit dwellings in Umeå, Sweden, with good results.</p><p>Note that the result of this report is a methodology and how the method should be performed within buildings erected by NCC in Umeå. It describes a functional and applicable method where the results can be compared between different objects. An internal quantity which describes the air permeability of the external wall has been developed.</p><p>A discussion of the relevance if the derived quantity and the standard has been made. The change in BBR to demands of the function for the energy use has been considered to be a driving force for knowledge. The procedure described in the results has been considered to be the optimum procedure for existing conditions with the standard available. A change in the standard would lead to a better method which would give more informative results.</p>
5

MÄTNING AV LUFTTÄTHET I FLERBOSTADSHUS : Gällande krav, praktiskt genomförda mätningar samt en tillämpbar metod

Sörensen, Ida January 2009 (has links)
Stor förvirring råder kring hur lufttätheten ska mätas i flerbostadshus. De metoder som finns och de resultat som erhålls vid täthetsprovning av småhus är inte alltid applicerbara på flerbostadshus även om mätenheterna är de samma. Detta föranleder problemställningen för detta examensarbete: Varför och hur kontrolleras lufttätheten i ett flerbostadshus på ett praktiskt tillämpbart sätt, som också gör det möjligt att jämföra resultat från olika objekt? Metoderna som används för att undersöka detta är litteraturstudier och samtal med erfarna personer, samt demonstration av en mätmetod i fullskala. En diskussion med initiativtagarna till detta examensarbete leder fram till en rekommenderad metod och en mall för hur detta ska utföras. Byggnadsskalets luft-, diffusions- och vindtätning har stor betydelse för en byggnads energianvändning, fuktsäkerhet, termiska komfort och hygien, luftkvalitet, ljudmiljö, spridning av brand samt spridning av luftföroreningar utifrån och in. Lufttätheten är en avgörande faktor både för konstruktionens beständighet och för en god innemiljö i moderna byggnader. Lufttäta hus är dessutom lönsamma i längden för de inblandade aktörerna. På lång sikt även för miljön. Studier som gjorts visar att en byggnads energiåtgång för uppvärmning minskar med nästan 30 % om lufttätheten (egentligen luftgenomsläppligheten) förbättras från 0,8 l/s·m2 till 0,4 l/s·m2. En så stor minskning av energianvändningen kunde inte åstadkommas med andra energiförbättringsåtgärder som undersöktes. I Boverkets Regelsamling för byggande, BBR 2008 har kravet på lufttäthet tagits bort till förmån för ett funktionskrav för energianvändningen, under vilken lufttätheten faller in. Regelsamlingens allmänna råd hänvisar till standarden, SS-EN 13829 för bestämning av luftläckage. De metoder som idag finns att tillgå för att mäta lufttätheten hos byggnader är spårgasmetoden, täthetsprovning med provisorisk vägg, det egna ventilationssystemet, med mottryck i angränsande utrymmen samt med tryckdörr. Den sistnämnda metoden provades på flerbostadshus i Umeå med goda resultat. Observera att resultatet för denna rapport är en mall för mätningsförfarandet och den rekommenderade metoden för att mäta lufttäthet inom NCC i Umeå. Den beskriver en praktiskt tillämpbar metod där resultatet går att jämföra mellan olika objekt. Även en intern mätstorhet som beskriver ytterväggens täthet är framtagen. Mätstorheten och standardens relevans diskuteras. Ändringen i BBR från specificerade krav till funktionskrav anses vara kunskapsdrivande. Det förfarande som beskrivs i resultatet har bedömts vara det mest optimala under rådande förhållanden med den standard som finns. En förändring av standarden skulle kunna leda till en bättre metod som ger mer informativt resultat. / There is a great perplexity about how air permeability should be measured in multiple-unit dwellings. The methods available and the obtained results for determination of air permeability in single-dwelling houses are not applicable for multiple-unit dwellings, even if the derived quantities are the same. This causes the problem for this report: Why and how should the air permeability be determined for a multiple-unit dwelling in a functional and applicable way, which also makes it possible to compare the obtained results from different dwelling units? The methods used to explore solutions are literature studies, conversation with professionals and a full-scale demonstration of one of the methods. A discussion with the initiators of this report leads to the recommended method and a model for how it should be performed. The air-, diffusion- and windtightness of the building envelope are of big importance to the building. The use of energy, moisture transfer, thermal comfort and hygiene, air quality, noise, spreading of fire and spreading of air pollutions are all affected by it. The air tightness is a crucial element for the durability of the building and to secure a good indoor environment. Air tight buildings are also cost-effective in the long run for the involved participants. They are also good for the environment. A study that have been made show that the energy-use for heating buildings will be reduced with almost 30 % if the air permeability improves from 0,8 l/s·m2 to 0,4 l/s·m2. Such a big reduction of the energy use could not be accomplished with any other energy improvement-move that was investigated in the study. The Swedish building regulations, Boverkets Regelsamling för byggande BBR, used to have a demand for the air tightness of buildings. It has been removed in favor of a demand of the function for the energy use, which also include the air tightness. The common advices in BBR refer to the standard, SS-EN 13829 for determination of air permeability. The methods available for determination of air permeability in buildings are the tracer-gas method, determination with a temporary wall, the ventilation system, with corresponding pressure in adjacent spaces and determination with a Blower Door. The last method was demonstrated in multiple-unit dwellings in Umeå, Sweden, with good results. Note that the result of this report is a methodology and how the method should be performed within buildings erected by NCC in Umeå. It describes a functional and applicable method where the results can be compared between different objects. An internal quantity which describes the air permeability of the external wall has been developed. A discussion of the relevance if the derived quantity and the standard has been made. The change in BBR to demands of the function for the energy use has been considered to be a driving force for knowledge. The procedure described in the results has been considered to be the optimum procedure for existing conditions with the standard available. A change in the standard would lead to a better method which would give more informative results.
6

“Den värsta fienden till makten är de som har det fria ordet” : Om adaptation som kollektiv teaterkonstnärlig gestaltningsprocess i Satans demokrati, en immersiv teaterföreställning inspirerad av Michail Bulgakovs Mästaren och Margarita

vande Voorde, Grazyna January 2023 (has links)
The purpose of investigation was to examine whether Satan´s democracy was an adaptation of The Master and Margarita. As a theoretical frame was used adaptation theory by Laera, Hutcheon and Babbage, Loman´s model for theatre performance analysis and the praxis of immersive theatre by Punchdrunk. The investigation was conducted as a comparative analysis of written and videotaped documentation and interviews of stage managers and actors. The results show that Satan´s democracy can be regarded as an intermedial transformation by temporal adaptation of The Master and Margarita to contemporary Swedish environment. A creative reinterpretation of the message about the individual´s impotence while facing superior political power is observed in Satan´s democracy. The geography and environment were reinterpreted by reshaping of space in a huge building that served entirely as stage and by use of art and music. Some characters were kept, some were recreated, some were created without distinct model in The Master and Margarita. Satan´s democracy was conducted as a collective theatre and art process of creation in distinct steps by almost 600 people during 2015- spring 2016. The production team applied and creatively developed immersive theatre form.

Page generated in 0.0572 seconds