• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 49
  • 21
  • Tagged with
  • 70
  • 57
  • 28
  • 27
  • 16
  • 14
  • 12
  • 11
  • 10
  • 9
  • 8
  • 7
  • 6
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Optiska Time-of-Flight sensorer kan användas för att mäta steghöjd och stegbredd under gång : En utvärdering av sensorer i en laborativ och reell miljö / Optical Time-of-Flight sensors can be used to measure step width and step height : An evaluation of sensors in a laborative and real environment

Edman, Agnes January 2017 (has links)
In some medical cases it is of interest to study a persons gait. This can be done in several different ways, both simple and advanced. A project has been done at the department Medicinsk Teknik - Forskning och Utveckling at the University Hospital of Umeå. In that project a system with optical triangulation sensors was created to easily measure a persons step width and step height. It was found that the sensors had limitations, in particular with sample frequency, and it was therfore of interest to test new sensors for this application. The goal with this project was to evaluate two sensors, VL53L0X and VL6180, and investigate if they can be used to measure step width and step hight. A system was built to communicate with and read data from the sensors. The sensors were then tested both in a laborative and real environment. With good reflection both VL6180 and VL53L0X show good precision in the range of interest. The sensors has the resolution of millimeters. VL6180 works better at really close distances but has a much shorter maximum range, about 18 cm, and lower maximum sample frequency, under 43 Hz. VL53L0X was tested up to 70 cm and 50 Hz. To be able to measure step width from the ankle, a very high sample frequency is needed to get the right amount of data when the legs pass eachother. If the sensors can be used in that way has not been confirmed. When placed higher on the persons leg, VL6180 can be used to measure step width and VL53L0X can be used to measure both step width and step height. / Inom sjukvården kan det i vissa fall vara intressant att studera en persons gång. Detta kan göras mer eller mindre avancerat och av olika anledningar som för diagnostik eller uppföljning efter ingrepp. Det har tidigare skapats ett mätsystem för mätning av gångparametrar på avdelningen Medicinsk teknik - Forskning och Utveckling vid Norrlands Universitetssjukhus. I det arbetet testades optiska sensorer som använder en triangulerande metodik. Den existerande tekniken hade dock begränsningar i sitt mätutförande vilket ledde till ett behov av att ersätta dessa med en ny typ av sensor. Målet med det här arbetet var därför att utvärdera två andra sensorer, VL6180 och VL53L0X, och undersöka om de kan användas för mätning av stegbredd och steghöjd. Ett mätsystem skapades i för att kommunicera med och samla in data från sensorerna. Därefter utfördes tester, främst laborativa tester med även ett test med den ena sensorn i reell miljö på testperson. Båda sensorerna visar på bra precision och linjäritet på de intressanta avstånden och ger resultat med en upplösning på hela millimetrar. VL6180 opererar bättre på väldigt nära håll men har en begränsning i att det maximala mätavståndet ligger kring 18 cm och den maximala samplingsfrekvensen under 43 Hz. Den frekvensen går att programmera men är instabil. För att kunna placera sensorerna nere vid vristen vid breddmätning krävs en mycket hög samplingsfrekvens för att få in tillräckligt med mätdata. VL53L0X kan komma upp i en en samplingsfrekvens på 50 Hz men det på bekostnad av sämre precision än vid lägre frekvenser. Huruvida VL6180 och/eller VL53L0X kan placeras vid vristen har inte bekräftats. VL53L0X testades med testperson och fungerade då för höjdmätning och breddmätning vid vaden. VL6180 bedöms kunna användas som sensor för mätning av stegbredd och VL53L0X för mätning av stegbredd och steghöjd.
32

Karakterisering av REE-förande mineral från Flintgruvan: en sydlig utlöpare av Falufältet i norra Bergslagen?

Orbe, Ragna January 2016 (has links)
Bergslagen är känt för sin mångfald av mineraliseringar liksom sällsynta element och mineral. Speciellt pegmatiter och vissa skarnförekomster har förhöjda koncentrationer av sällsynta jordartsmetaller (REE på engelska) och REE-förande mineral. Pegmatitprover från Flintgruvan, som ligger i norra Bergslagen (Dalarna), karakteriserades i den här studien. Proven som studerades innehöll flera REE-förande mineral; (Y,REE,U,Th)-(Nb,Ta,Ti)-oxider av AB2O6-typ, xenotim-(Y) och (Y,Yb)-förande thorit. Pegmatiten klassificerades som varandes av NYF-(Niob-Yttrium-Fluor) typ på grund av de förhöjda koncentrationerna av niob (Nb), yttrium (Y) och titan (Ti) i de undersökta faserna. Förutom yttrium så innehöll pegmatiten små koncentrationer av andra HREE (tunga sällsynta jordartsmetaller) som ytterbium (Yb) och dysprosium (Dy). (Y,REE,U,Th)-(Nb,Ta,Ti)-oxiderna innehöll även relativt höga halter av kisel (Si). På basis av de kemiska analyserna representerar dessa strakt omvandlade faser antingen aeschynit eller polykras som ursprungsmineral. Undersöknings- och analysmetoderna som användes i studien var polarisationsmikroskopi och svepelektronmikroskopi med energidispersiv spektroskopi (SEM-EDS). / Bergslagen is known for its diversity of rare elements and minerals. Especially granitic pegmatites and some uncommon types of skarn deposits have shown higher concentrations of rare earth elements (REE) and REE-bearing minerals. Samples of a granitic pegmatite from Flintgruvan, which is located in northern Bergslagen (Dalarna), were characterized in this study. The samples that were studied were found to contain several REE-rich minerals such as (Y,REE,U,Th)-(Nb,Ta,Ti) oxides of AB2O6 type, xenotime-(Y) and an Y+Yb-bearing thorite. The most abundant AB2O6 type oxides were found to represent strongly altered minerals, either belonging to the aeschynite or polycrase group. Based on mineral chemical studies, the pegmatite was classified as being of the NYF (Niobium-Yttrium-Fluorine) type due to the predominance of yttrium (Y) and niobium (Nb) as well as notable titanium (Ti) concentrations. Other than yttrium the samples contained small concentrations of other HREE (heavy rare earth elements) such as ytterbium (Yb) and dysprosium (Dy). The (Y,REE,U,Th)-(Nb,Ta,Ti) oxides also contained a relatively high content of silicon (Si). The mineralogical characterization was done by means of reflected polarized light microscopy and scanning electron microscopy with energy dispersive spectroscopy (SEM-EDS).
33

High-capacity short-reach optical communications

Lin, Rui January 2016 (has links)
The global traffic is experiencing an exponential growth posing severe challenges to the communication networks in terms of capacity. As a future-proof technology fiber communication is widely implemented in different network segments, which can be categorized by transmission distance as long-haul and short-reach. This thesis focuses on the short-reach communication networks including fiber access network connecting the end users to the metro/core networks that covering tens of kilometers and optical datacenter network handling the traffic within the datacenter with distance up to a few kilometers. For fiber access networks, wavelength division multiplexing passive optical networks (WDM-PONs) assign a dedicated wavelength channel to each user guaranteeing high data rate. Dense channels enlarges the user count but makes the signals vulnerable to the wavelength drift. In this regard we propose two schemes based on optical frequency comb technique to generate stable carriers for WDM-PONs. Meanwhile, radio-over-fiber techniques allows the transmission of radio signals between central offices and the cells. Millimeter wave (MMW) over fiber, on the other hand, offer high bandwidth for future high capacity mobile access. We propose and experimentally demonstrate a palm-shaped spectrum generation where the high-power central carrier can be used for upstream transmission while multiple MMW bands are capable of transmitting different downstream data simultaneously. Regarding optical datacenter networks, passive optical interconnects (POIs) have been proposed as an energy-efficient solution since only passive optical components are used for server interconnection. However, the high insertion loss may result in a scalability problem. We develop a methodology that considers various physical-layer aspects, e.g., receiver types, modulation formats, to quantify the scalability of POIs. Both theoretical analyses and experimental measurements have been performed to assess the scalability of various coupler-based POIs. / Den globala datatrafiken växer exponentiellt, både på grund av nya bandbreddskrävande applikationer och ökningen av antalet användare. Detta innebär en utmaning för kommunikationsnätens kapacitet. Fiberoptisk kommunikation är en framtidssäker teknik för att möta detta kapacitetsbehov och används redan i stor utsträckning i olika delar av näten. Beroende på överföringsavstånd, kan fibernät kategoriseras som långdistansnät eller nät med kort räckvidd. Denna avhandling behandlar nät med kort räckvidd, innefattande dels 1) accessnät som förbinder slutanvändarna till stadsnätet/ huvudnätet och typiskt omfattar tiotals kilometer, dels 2) optiska datanätverk som hanterar den interna trafiken inom datacenter med överföringsavstånd upp till ett par kilometer.För fiberaccessnät är en av de lovande teknikerna våglängdsmultiplexade passiva optiska nät (WDM-PON), där en dedicerad våglängdskanal tilldelas varje användare vilket garanterar hög datahastighet. Genom ett litet kanalavstånd så kan antalet användare i WDM-PON utökas men det gör samtidigt systemet känsligt för våglängdsdrift hos lasrarna. För att råda bot på detta, föreslår vi två system baserade på optisk frekvenskams-teknik. Vi validerar experimentellt att de kan generera stabila optiska bärvågor för WDM-PON. Radio-över –fiber-tekniken gör samtidigt det möjligt att sända radiosignaler över en lång sträcka och används därför i mobilsystem för överföring mellan centralstationen och radiocellerna. Millimetervågor (MMW) över fiber erbjuder ännu större modulationsbandbredd och är lovande för framtidens mobilradiosystem med hög kapacitet. I denna avhandling föreslår vi, och demonstrerar experimentellt, generation av ett frekvenskams-spektrum som är format som en handflata, där en central bärare med hög effekt (långfingret på handflatan) kan användas i radiocellerna för uppströms överföring, medan multipla MMW band (övriga fingrar) samtidigt kan överföra olika data nedströms. När det gäller nätverk för optiska datacenter, har passiva optiska interconnects (POI) föreslagits som en energieffektiv lösning, där endast passiva optiska komponenter används för ihopkoppling av servrarna. Höga inkopplingsförluster hos passiva optiska komponenter kan emellertid leda till allvarliga skalbarhetsproblem. I denna avhandling presenterar vi en nyutvecklad metod för att kvantifiera skalbarheten, vilken tar hänsyn till olika faktorer i det fysiska lagret som t.ex. mottagartyp och modulationsformat. Både teoretiska analyser och experimentella mätningar har utförts för att utvärdera skalbarheten hos olika kopplarbaserade POI. / <p>QC 20161117</p>
34

Analys av trombocyter i blodkomponenter: En jämförelse mellan tre olika mätmetoder på Sysmex XN-1000

Vikman, Frida January 2019 (has links)
No description available.
35

Optical Characterization and Optimization of Display Components : Some Applications to Liquid-Crystal-Based and Electrochromics-Based Devices

Valyukh, Iryna January 2009 (has links)
This dissertation is focused on theoretical and experimental studies of optical properties of materials and multilayer structures composing liquid crystal displays (LCDs) and electrochromic (EC) devices. By applying spectroscopic ellipsometry, we have determined the optical constants of thin films of electrochromic tungsten oxide (WOx) and nickel oxide (NiOy), the films’ thickness and roughness. These films, which were obtained at spattering conditions possess high transmittance that is important for achieving good visibility and high contrast in an EC device. Another application of the general spectroscopic ellipsometry relates to the study of a photo-alignment layer of a mixture of azo-dyes SD-1 and SDA-2. We have found the optical constants of this mixture before and after illuminating it by polarized UV light. The results obtained confirm the diffusion model to explain the formation of the photo-induced order in azo-dye films. We have developed new techniques for fast characterization of twisted nematic LC cells in transmissive and reflective modes. Our techniques are based on the characteristics functions that we have introduced for determination of parameters of non-uniform birefringent media. These characteristic functions are found by simple procedures and can be utilised for simultaneous determination of retardation, its wavelength dispersion, and twist angle, as well as for solving associated optimization problems. Cholesteric LCD that possesses some unique properties, such as bistability and good selective scattering, however, has a disadvantage – relatively high driving voltage (tens of volts). The way we propose to reduce the driving voltage consists of applying a stack of thin (~1µm) LC layers. We have studied the ability of a layer of a surface stabilized ferroelectric liquid crystal coupled with several retardation plates for birefringent color generation. We have demonstrated that in order to accomplish good color characteristics and high brightness of the display, one or two retardation plates are sufficient.
36

Utveckling av handhållen prototyp för mätning av EKG och fingerpuls / Development of Handheld Prototype for Measuring ECG and Fingerpulse

Borghäll, David, Lundström, Mathilda January 2019 (has links)
Denna rapport representerar ett kandidatexamensarbete vid Kungliga Tekniska Högskolan(KTH), där målet var att skapa en handhållen prototyp. Funktionerna för prototypen var mätning av puls i ett finger med optiska sensorn TCRT1010 och elektrokardiografi(EKG) med bipolära extremitetsavledningar. Prototypen är skapad med målet att vara användarvänlig, kostnadseffektiv och billig för att kunna appliceras i utvecklingsländer som finns i Afrika och Asien. Anledningen är då det finns brist på billig och lätthanterlig medicinsk teknik i de områden. Arbetet utfördes genom utveckling av två kretsar givna av uppdragsgivaren, för att sedan designas på ett kretskort som tillverkades av ett svenskt företag. Samtliga komponenter löddes fast på kretskortet och monterades i en behållare med uttag och batterier. Den slutgiltiga prototypen består av en plastlåda som innehåller kretskortet med funktionen att mäta antingen pulsen i ett finger eller EKG, som användaren väljer med hjälp av en switch. Prototypen är även utrustad med avtagbart lock, två BNC kontakter för signalutskick till oscilloskop, en för vardera krets, tre labbhylsor för extremiteterna och ett 4-polig kontakt för den optiska sensorn. Signalerna som fås är ej brusfria men innehåller respektive signals viktigaste parametrar för kontroll om vidare diagnostisk behövs. Den framtagna prototypens kostnad slutade på 1815,5 SEK, vilket ej ansågs uppfylla målet för kostnadeffektivet men som anses kunna användas i utvecklingsländer då prototypen har en simpel design, med avtagbart lock som möjliggör lätta batteribyten, endast en switch och är kompakt som gör den lätt att utföra undersökningar med. Signalhanteringen är testad för att ge tydlig signal som möjliggör att vårdpersonal kan identifiera om vidare diagnostik behövs. Många framtida förbättringar identifierades, så som att minska kostnaden med byte till billigare komponenter och massbeställning av kretskort, göra prototypen trådlöst kopplad till mätinstrument eller minska brus ytterligare. / This report represents a bachelor thesis at the Royal Institute of Technology, where the goal was to create a handheld prototype. The functions of the prototype were measuring pulse in a finger using the optical sensor TCRT1010 and electrocardiogram(ECG) with bipolar limb-lead. In this thesis, the focus was put on trying to develop a user-friendly and cost-effective prototype for use in developing countries, that can be found in Africa and Asia. The reason is because there's a lack of cheap and easy to use medical equipment in those areas. The work was performed by developing two circuits, given by our employer, that was designed on a circuitboard and constructed by a Swedish circuitboard constructor. All components were soldered on the circuitboard and was mounted in a box with socket and batteries. The finished prototype consists of a plastic box containing one circuitboard with the function to measure either the puls of a finger or ECG, which the user can choose between using a switch. The prototype is also equipped with a removable lid, two BNC plugs for connecting an oscilloskope, one for each ciruit, three sockets for the limb lead for the ECG and finally a 4-pole socket for the optical sensor. The signals acquired are not free of noise but contains the most important parameters of the two signals for guidance if further medical diagnostic is needed. The prototypes final cost was 1815,5 SEK, which was not considered achieving the goal for cost-efficiency, was still believed to be useful in developing countries because of its simpel design with removable lid and easily to change batteries. It's equipped with only one switch and the compact size makes it easy to handle. The signal processing is tested to give a clear signal which enables the health professionals to identify if further diagnostics are needed. Several improvements was identified for future work, such as to reduce the cost by buying cheaper components or buying the circuitboard in greater numbers, making a wireless connection to the measuring equipment or further reducing the noise.
37

Design of a 200Gbps externally modulated laser for opto-electronic integration / Design av en 200 Gbps externmodulerad laser för opto-elektronisk integration

Jiang, Tianyu January 2022 (has links)
Segmented traveling wave electro-absorption modulators (TWEAMs) can provide a modulation speed above 100 Gb/s, which is needed in new optical communication networks. In the EU-project TWILIGHT, KTH continues the design work of TWEAMs in the EU-projects IPHOBAC and HECTO with the aim to design a new optical modulator to be integrated with an electronic layer. The structure of the modulator has to be changed in order to make it compatible with the integration technology that will be used in the project. Like in previous projects, the PSPICE software is an important tool for the design work. The past studies left a large amount of different models and test data. This thesis has been focused on studying these models and data to see if they can help the future work in the project. This includes the comparison of the geometrical dimensions, the microwave properties, and the simulation results with the fabricated modulators in the past projects. The electrical parameters are also critical for the design work, especially the capacitance which determines the impedance of the modulator. Since the TWILIGHT project needs a new design of the modulator, the calculation of these parameters will change. This thesis contains a study how this can be done and discusses the parameters for the new TWEAM design. / Segmenterade elektroabsorptionsmodulatorer för vandrande vågor (TWEAMs) kan ge moduleringshastigheter över 100 Gb/s, vilket behövs i nya optiska kommunikationsnätverk. I EU-projektet TWILIGHT fortsätter KTH designarbetet av TWEAMs i EU-projektet IPHOBAC och HECTO med syfte att designa en ny optisk modulator som ska integreras med ett elektronik-lager. Modulatorns struktur måste ändras för att den ska bli kompatibel med integrationstekniken som ska användas i projektet. Precis som i tidigare projekt är PSPICE-mjukvaran ett viktigt verktyg för designarbetet. Den tidigare studierna lämnade en stor mängd olika modeller och testdata. Detta examensarbete har fokuserat på att studera dessa modeller och data för att se om de kan hjälpa det framtida arbetet i projektet. Detta inkluderar jämförelsen av de geometriska dimensionerna, mikrovågsegenskaperna och simuleringsresultaten med de tillverkade modulatorerna i tidigare projekt. De elektriska parametrarna är också kritiska för konstruktionsarbetet, speciellt kapacitansen som bestämmer modulatorns impedans. Eftersom TWILIGHT-projektet har en ny design för modulatorn, ändras beräkningen av dessa parametrar. Detta examensarbete innehåller en studie hur detta kan göras och diskuterar parametrarna för den nya TWEAM-designen.
38

FPGA Implementation of an Online Free-Space Optical Communications Test-Bed / FPGA Implementering av en Realtid Free-Space Optisk Kommunikationstestbänk

Mahmoud, Hamza January 2023 (has links)
Free Space Optical (FSO) satellite communications is proving to be a key enabling technology for global connectivity with the ability to provide connection across Europe with only 12 ground stations. For this, Deutsches Zentrum für Luft- und Raumfahrt (DLR) is working on implementing a robust communication system for FSO on a Xilinx RFSoC Field Programmable Gate Array (FPGA)( ZU28DR). However, FSO is susceptible to deep fades and atmospheric turbulence affecting the quality of the communication system. Thus, measuring the performance of the communication system is crucial for choosing system parameters and designing new blocks to enhance the performance. In this thesis, a high speed test-bed implementation exploiting Parallel Pseudo Random Binary Sequence (PRBS) to measure the performance of the system is implemented. The test-bed is designed to mitigate channel fading problems to correctly calculate the Bit Error Rate (BER). The test-bed is designed to allow for online adjustment of the communication system to facilitate parameter optimizations. / FSO-satellitkommunikation visar sig vara en viktig teknologi för global anslutning med förmågan att tillhandahålla anslutning över Europa med endast 12 markstationer. För detta arbetar DLR med att implementera ett robust kommunikationssystem för FSO på en Xilinx RFSoC FPGA (ZU28DR). Men FSO är känsligt för djupa fades och atmosfärisk turbulens som påverkar kvaliteten på kommunikationssystemet. Därför är mätningen av systemets prestanda avgörande för att välja systemparametrar och designa nya block för att förbättra prestanda. I denna avhandling implementeras en höghastighets testbädd som utnyttjar parallel PRBS för att mäta systemets prestanda. Testbädden är designad för att motverka kanalförlustproblem för att korrekt beräkna BER. Testbädden är designad för att tillåta justering av kommunikationssystemet online för att underlätta optimering av parametrar
39

Development of a Method to Predict the Adhesion of Industrial Paint Coating / Utveckling av en metod för att förutsäga vidhäftning av industriella färger

Sadik, Akheen January 2022 (has links)
I samarbete med Sherwin-Williams AB, utvecklades en metod med kontaktvinkelmätning för att teoretiskt uppskatta vätbarhet och vidhäftningsförmåga av industriella färger på stålsubstrat. Optisk tensiometer och Youngs ekvation kombinerat med OWRK beräkningsmodell användes för att bestämma ytenergier. Det föreslogs att kontaktvinkelmätning bör inkludera bestämning av ytenergi av det fasta substratet, ytspänning av färgen samt beräkning av polaritet och gränssnittsenergi mellan de två bindande ytorna, för att stämma bra överens med färgens praktiskt uppskattade vidhäftningsförmåga. Det konstaterades att kontaktvinkel är en nödvändig faktor för att få information om teoretisk bindningsstyrka mellan två bindande ytor, men stämde någorlunda bra med praktiskt uppskattad vidhäftningsförmåga från mekanisk testmetod. Vidare studier utfördes för att identifiera styrkor och svagheter med kontaktvinkelmätningen och förstå inverkan av olika huvudegenskaper av färger på dess vidhäftning. Fem olika lösningsmedelsbaserade färger av typen två-komponentsystem tillverkades i syfte att studera effekter från två olika vidhäftningsfrämjande additiv, ett epoxysilan och ett aminosilan samt två olika fyllnadsmedel, kieseldioxid (SiO2) pulver och CaCO3/BaSO4 pulverblandning. Det konstaterades att silan inte förbättrade vidhäftning av färgerna på metallsubstraten, på grund av den snabba exoteriska reaktion som sker mellan silan och isocyanat härdare komponent B, när det blandas med färgen (komponent A). Till följd fås hastig viskositets- och temperaturökning som ökade avdunstning av lösningsmedlet och orsakade försämrad utplaning och flöde av färgen på metallytan. Det konstaterades även att fyllnadsmedlet CaCO3/BaSO4 var bättre än kiseldioxid (SiO2), delvis på grund av lägre oljeabsorptionsvärde som resulterar i lägre viskositetökning och bättre flöde av färgen. Rekommendationer för framtida studier är att analysera effekter av silan i ett en-komponentsystem för att eliminera effekter av snabb avdunstning av lösningsmedel och härdningskinetik mellan färg (komponent A) och härdare (komponent B). Reologi studier med reometer kan användas för att få mer information om varför CaCO3/BaSO4 visades vara ett bättre fyllnadsmedel än kiseldioxid. / In collaboration with Sherwin-Williams AB, a method with contact angle technique was developed to theoretically predict wettability and adhesive bonding between industrial paint coatings and steel substrates. The technique used was optical tensiometer and Young’s equation combined with OWRK calculation model was used to determine surface and interfacial energetics. It was suggested that the contact angle measurements must include measurements of the surface energy of the solid, surface tension of the liquid paint and calculation of polarity and interfacial tension between the bonding surfaces, to best correlate with practically estimated adhesion property of the paint coatings. It was stated that though contact angle proved to be a prerequisite factor to acquire information about adhesive bonds between two bonding surfaces, it did not entirely correlate with the findings from practically estimated adhesion performance from pull-off investigations. Work was dedicated to identifying strengths and weaknesses with the contact angle measurements and understanding the impact of other key properties of the paint coatings on adhesion performance. Five different solvent-based, two-component paint systems were manufactured to be able to see the effects on adhesion performance from two adhesion promoting additives, an epoxysilane and an aminosilane, as well as two different filler packages: silicon dioxide SiO2 (silica) filler package and CaCO3/BaSO4 filler package, respectively. It was concluded that the silanes did not improve adhesion performance of the paint coatings because of fast exothermic reaction that takes place between silane and isocyanate hardener component B when added to the liquid paint component A. Rapid viscosity rise and temperature rise was observed, which increased the evaporation rate of the solvent and impaired the leveling and flowing of the paint coating to the steel substrates. It was also unexpectedly observed that the CaCO3/BaSO4 filler package outperformed the silica filler package, partly because of its lower oil absorbance, which resulted in lower viscosity rise and better flowing of the paint coating. For future studies, it was recommended to analyze effects of the silanes in a one-component paint system to eliminate unfavored effects from evaporation of the solvent and cure kinetics of paint component A and isocyanate hardener component B. The superior paint quality contributed from the CaCO3/BaSO4 filler package could be better understood by rheology investigations with rheometer.
40

Lipemi-interferens vid mätning av Hb på Sysmex XN-10 och HemoCue Hb 201+ / Lipemic interferens on the measurement of Hb on Sysmex XN-10 and HemoCue Hb 201+

Andersson, Sebastian January 2019 (has links)
Anemi kan uppstå till följd av förlust av erytrocyter eller försämrad produktion av nya erytrocyter. För att upptäcka och följa upp patienter med anemi är det viktigt att korrekt kunna mäta hemoglobinkoncentrationen (Hb) i blodet. En vanlig metod för att mäta Hb-koncentration är fotometri i kombination med en kemisk omvandling. Liksom alla mätningar med ljus är dessa känsliga för turbiditet i provet. Lipemi är en vanlig källa till turbiditet som kan uppstå till exempel som följd av en fettrik måltid, diabetes mellitus, lever- eller njursjukdomar, alkoholism och vissa läkemedel. Olika instrumenttillverkare har olika metoder för att motverka interferensen av lipemi. Sysmex hematologi-instrument XN-10 använder en fettlösande bärarvätska i sin fotometriska kanal (HGB) och HemoCue mäter vid en andra våglängd som ska kompensera för turbiditet. Sysmex XN-10 har också en optisk kanal (HGB-O) som är till för att räkna retikulocyter genom att mäta deras nukleinsyra- samt Hb-innehåll men ger då också ett beräknat värde på Hb-koncentrationen i hela provet. Syftet med denna studie var att jämföra HGB och den HGB-O för bestämning av Hb-koncentrationen i helblod. Båda kanalerna jämfördes även med HemoCue Hb 201+ vid bestämning av Hbkoncentrationen i svårt lipemiska prover. Hb-mätning på plasma från motsvarande prover utfördes också för att undersöka om värdet motsvarade Hb-höjningen i de lipemiska proverna. Prover analyserade med både HGB och HGB-O på Sysmex XN-10 på klinisk kemi vid Skånes universitetssjukhus i Lund under november månad 2018 (n = 392) jämfördes med hjälp av Spearmans rangkorrelationskoefficient. Lipemi simulerades med fettemulsionen Intralipid i totalt 32 prover. Färdiganalyserade patientprover från föregående dag delades i ett lipemiskt prov med Intralipidtillsats och ett nollprov med tillsats av NaCl-lösning i en motsvarande volym. Differenserna mellan de lipemiska- och nollprovernas Hb-värden testades för signifikans med icke-parametrisk Wilcoxons teckenrangtest. Kruskal-Wallis samt Dunns's tester användes för att visa på signifikanta skillnader mellan de tre metoderna. Signifikansnivån sattes vid p &lt; 0,05. Resultaten visade god korrelation mellan HGB - och HGB-O Hb-värden med ett Spearman korrelationsvärde på 0,982.  Jämförelsen av metoderna vid lipemi visade signifikant skillnad mellan nollprov och lipemiskt prov för HGB- (p &lt; 0,001) men inte HGB-O (p = 0,11) på XN-10. HemoCue Hb 201+ visade också signifikant skillnad (p &lt; 0,001) vid lipemi men med lägre median-värde än HGB och mindre spridning än HGB-O. HGB-O:s median-värde tydde på minst lipemipåverkan men spridningen av differenserna var stor. Spridningen av HGB-O resultaten kan bero på hemolys då endast intracellulärt Hb mäts i denna kanal. Resultaten i denna studie tyder på att HemoCue-metoden är den mest pålitliga vid Hb-mätning av lipemiska prover och därmed det lämpligaste komplementet till HGBmetoden / Anemia can arise from either loss of erythrocytes or impaired production of new erythrocytes. In order to discover and evaluate the treatment of anemic patients, correct Hb measurements are important. A common method to measure Hb concentration is photometry in combination with chemical conversion of the Hb. Like all light-dependent methods this suffers from a vulnerability to turbidity that scatters light. Lipemia is a common cause of turbidity caused by e.g. recent intake of high fat foods, diabetes mellitus, liver or kidney disease, alcoholism and some drugs. Manufacturers of Hb analyzers use different methods to counter the influence of interference from lipemia on measurements. Sysmex XN-10 analyzers use a fat dissolving sheath fluid in its photometric channel (HGB) and HemoCue measures absorbance at a second wavelength to compensate for turbidity. Sysmex XN-10 also has an optic channel (HGB-O) for counting reticulocytes by measuring their nucleic acid and Hb content. At the same time this channel measures Hb equivalents of erythrocytes and gives a calculated value of Hb content in the entire sample. The aim of this study was to compare the photometric and the optical channels for measuring Hb concentration in whole blood. Both the Sysmex XN-10 channels were compared with HemoCue Hb 201+ when measuring Hb concentrations in lipemic samples. Plasma Hb concentration was determined for the corresponding samples in order to investigate correlation between elevation in Hb concentration with and without simulated lipemia and in the plasma after centrifugation. Samples analyzed at Skånes University Hospital in Lund during the month of November 2018 (n = 392) using both HGB and HGB-O on XN-10 were compared using Spearman's signed correlations coefficient. Lipemia was simulated by using the fat emulsion Intralipid in a total of 32 samples. Samples collected and analyzed on the previous day was used for the study. Each sample was split into one part with added Intralipid to form a lipemic sample and one part with NaCl-solution of the same volume as Intralipid in the lipemic sample. The differences between lipemic and non lipemic samples was tested for significance by the non-parametric Wilcoxons signed ranks test for each of the methods. Significance between the three methods was tested by using Kruskal-Wallis and Dunn's tests. Level of significance was set to p &lt; 0.05. The results showed good correlation between earlier test run on both HGB and HGB-O with a Spearman correlation score of 0,982.  A significant difference was found between lipemic and non lipemic samples with the photometric method (p &lt; 0,001) but not the optical method (p = 0,11) on XN10. HemoCue Hb 201+ also showed a significant difference (p &lt; 0,001) between lipemic and non lipemic samples but a lower median than HGB and less deviation than HGB-O. The median of HGB-O indicated that it was influenced the least by lipemia of the three methods but had the greatest deviation of the differences. The greater deviation of HGB-O values may have been caused by hemolysis since the method measures intra cellular Hb. HemoCue shows according to this study the slightest deviation of the three methods and a less heightened median value compared to HGB which confirms the methods suitability as complement to HGB when dealing with lipemic samples.

Page generated in 0.0338 seconds