• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 287
  • 265
  • 38
  • 10
  • 9
  • 7
  • 6
  • 5
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • Tagged with
  • 673
  • 255
  • 143
  • 127
  • 125
  • 118
  • 117
  • 95
  • 84
  • 79
  • 61
  • 58
  • 58
  • 56
  • 55
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
441

AVALIAÇÃO DO TORQUE DE FRATURA DE MINI-IMPLANTES SUBMETIDOS À ATÉ TRÊS REUTILIZAÇÕES / STUDY OF THE EFFECTS OF STERILIZATION AND REUSE OF MINI-SCREWS, UP TO THREE TIMES, ON TORQUE REQUIRED TO FRACTURE

Miotti, Fabrício Lamberti 29 July 2016 (has links)
Orthodontists have been reusing mini-implants that fail after installation or that will be inserted in a new place due to mechanic needs in order to optimize clinical time. The aim of this study was to simulate the reuse of mini-implants up to three times and evaluate their potential weakness. We used 48 screws (Morelli, Sorocaba, Brazil), which were divided into four groups: C= Control, G1 = one reuse, G2 = two reuse, G3 = three reuse. In order to simulate inserts in patients mouths, we used pig iliac bone. After we insert screws on bone specimen, we removed, cleaned, and sterilized them by autoclaving. The guide at the machine we used allowed us to standardize installations. After all groups were submitted to their reuse periods, mini-implants were submitted to fracture, and the strongest force necessary to break them was measured by a digital axial torquemeter. We used bovine tibia specimens for fracture, because of its greater bone cortical and bone density. We used One Way ANOVA (Bonferroni post-hoc) to compare means of each group. Results showed differences statistically significant between G3 and the other groups. All mini-implants needed strength higher than recommended by the literature to be inserted into patients, even though we found differences in fracture resistance between groups. / Na busca por não perder tempo clínico, ortodontistas vêm reutilizando mini-implantes que falham após a instalação ou que serão instalados em novo local devido à necessidades mecânicas. O objetivo deste estudo foi simular a reutilização de miniimplantes em até três vezes e avaliar a possível fragilização dos mesmos. Para isso, foram utilizados 48 parafusos (Morelli Sorocaba-SP, Brasil), os quais foram divididos em quatro grupos: C = Controle, G1 = uma reutilização, G2 = duas reutilizações e G3 = três reutilizações. Para simular, laboratorialmente, as instalações em boca nos pacientes, foi utilizado osso ilíaco suíno. Após serem inseridos no espécime de osso, os parafusos foram removidos, limpos e esterilizados em autoclave. Com um guia presente na máquina utilizada foi possível padronizar as instalações. Após todos os grupos passarem pelos ciclos de reutilização correspondentes, os mini-implantes foram submetidos à fratura, e a força máxima necessária para a quebra foi medida através de um torquímetro digital axial. Para a fratura, foram utilizados espécimes de tíbia bovina, por possuir maior densidade óssea e espessura de cortical. Os valores médios dos grupos foram analisados pela ANOVA de 1 fator com post-hoc em Bonferroni. Foram encontradas diferenças estatisticamente significativas entre o grupo G3 e os demais grupos. Mesmo com as diferenças na resistência à fratura entre os grupos, todos necessitaram de forças superiores às recomendadas para instalação em pacientes.
442

Estudo comparativo in vivo e in vitro da resistência ao cisalhamento de braquetes metálicos colador com resina polimerizada com luz halógena e LEd

Penido, Sérgio Milton Martins de Oliveira [UNESP] 30 May 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:33:22Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-05-30Bitstream added on 2014-06-13T19:44:08Z : No. of bitstreams: 1 penido_smmo_dr_arafo.pdf: 996491 bytes, checksum: 142106818d9d76c3991a99fe95fe589a (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Este trabalho teve como objetivo avaliar a resistência ao cisalhamento, in vivo e in vitro, de braquetes metálicos (Abzil Lancer) colados em dentes humanos com material adesivo polimerizado xom luz halógena e LED. Os braquetes foram cotados em 60 pré-molares formando seis grupos. Nos Grupos I e II os braquetes foram colados nos segundos pré-molares respectivamente no lado direito e esquerdo dos pacientes. A polimerização do material adesivo foi com a luz de LED epara o GI e luz halógena para o GII. Nos demais grupos os braquetes foram colados em primeiros pré-molaressuperiores e inferiores extraídos por motivos ortodônticos. A polimerização realizada nos grupos III e V foi com o aparelho de LED enquanto que nos grupos III e V foi com o aparelho de LED enquanto que nos grupos IV e VI com luz halógena. Nos Grupos I e II testes de cisalhamento foram realizados utilizando-se dinamômetro sigital portátil diretamente na boca dos pacientes. Os grupos IIII, IV, V e VI foram armazenados em água destilada e levados a estufa a 37ºC por 24 horas e posteriormente, submetidos a termociclagem, com 1000 ciclos a 5 e 55ºC. Posteriormente, nos grupos III e IV, utilizou-se máquina universal de ensaios mecânicos e nos grupos IV e VI os ensaios mecânicos foram realizados com dinamômetro digital. Os valores médios da resistência ao cisalhamento em Mpa foram de: GI = 3,65; GII = 4,39; GIII = 6,45; GIV = 7,11; GV = 4,67; GVI = 4,21. Após a descolagem foram realizadas fotografias Das áreas de colagem. As imagens obtidas foram ampliadas %x, analisadas e classificadas de acorso com o índice de Adesivo Remanescente (IAR). Os resultados dos testes mecânicos in vivo ou in vitro. Os testes realizados com equipamento portátil digital tiveram valores médios significativamente menores em relação áqueles realizados em máquina de ensaios mecânicos universal. Não houve relação definida entre carga de ruptura e tipo de falha. / This work as a purpose to assess the shear bond strength, in vivo and in vitro , of metallic brackets (Abzil lancer) bondedto human teeth with light-curing bonding material with halogen and led lights. The brackets were bonded to 60 premolars, so forming 6 groups.In GI and II the brackets were bonded to second premolars, resectively, on the right and left sides of the patients. The polymerization of the bonding material was with LED light for GI and halogen light for GII. In the other groups the brackets were bonded to superior and inferior first premolars, extrated for orthodontic reasons. The polymerizatio was performed in GII and V with LED device, while in GIV and VI eith halogen light. In GI and II shear strength tests were made using a portable digital dynamoter directly in the patients' mouths. GII, IV, V and VI were stored in distilled water and taken to sterilizer at 37ºC for 24 hours, and afterwards, submitted to thermocycling with 1000 cycles at 5 and 55 º. Then, in GIII and IV, the Universal testing machine was used and in GIV and VI the mechanical tests were performed with a digital dynamometer. The average values of shear strength in Mpa were: GI=3,65; GII=4,39; GIII=6,45; GIV=7,11; GV=4,67 and GVI=4,21. Pictures of thebonding areas were taken after the tests. The images obtained amplified 5 times, analyzed and classified, according to Adhesive remaining index (IAR). The results suggested that the LED light or the halogen light did not interfere in the results of the mechanical tests in vivo or in vitro. The tests performed with a portable digital device obtained average values significantly lower than those performed with Universal testing machine. There was no definite relation between shear bond strengths and kind of failure.
443

Minimplante e botão lingual como ancoragem para retração inicial de caninos superiores: estudo prospectivo

Arantes, Flávia de Moraes [UNESP] 29 May 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:33:23Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-05-29Bitstream added on 2014-06-13T21:05:59Z : No. of bitstreams: 1 arantes_fm_dr_araca.pdf: 917045 bytes, checksum: 35b80ca88f794114ea01fe8fe638b23f (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / A preocupação com a ancoragem é um dos principais fatores a serem considerados no planejamento de um tratamento ortodôntico. Entendem-se como ancoragem os procedimentos intra e extrabucal em que um ou mais dentes ou dispositivos ortodônticos são utilizados como apoio para movimentar outros dentes. A utilização mais frequente dos implantes decorre de uma menor colaboração do paciente, não prejudica a sua estética e ainda cria um sistema de forças mais definido. Por essas razões e pela utilização clínica dos minimplantes de forma indiscriminada, surgiu o interesse em estudar a perda de ancoragem relacionada aos minimplantes. O objetivo deste trabalho foi comparar, por meio de telerradiografias, panorâmicas e modelos, a perda de ancoragem após a retração inicial de caninos superiores entre dois grupos. Foram selecionados 18 pacientes, divididos em dois grupos aleatórios de 9 indivíduos cada um (A e B), triados para tratamento ortodôntico na Faculdade de Odontologia de Araçatuba – UNESP, Disciplina de Ortodontia. O grupo A utilizou o minimplante enquanto o grupo B utilizou botão lingual. Para todos os pacientes foram realizadas duas telerradiografias (T1 e T2), duas panorâmicas (P1 e P2) e dois modelos (M1 e M2). Os primeiros exames complementares foram realizados ao início (T1, P1 e M1), e o outro, ao final da retração inicial de canino (T2, P2 e M2). Foi eleita a segunda fase (retração inicial de canino), devido à grande perda de ancoragem que se tem neste estágio do tratamento. Todas as medidas foram tabuladas e submetidas a análise estatística. Para comparação entre as fases Início e Após foi utilizado o teste “t” pareado. Para a comparação entre os grupos de minimplante e botão lingual foi utilizado o teste “t” de Student para medidas independentes. Em todos os testes foi adotado nível de significância de 5% (p<0,05). Todos os cálculos... / The concern with the anchorage is one of the main factors to be considered when planning an orthodontic treatment. Anchorage comprehends intra and extraoral procedures in which one or more teeth or orthodontic devices are used as a support for moving other teeth. The use more constant of implants is derived from a poor patient collaboration, does not impair the esthetics and still creates more defined forces system. For these reasons and because of the mini-implants clinical utilization in an indiscriminate way, there was an increased interest in studying anchorage loss related to mini-implants. The purpose of this study was to compare, by means of teleradiographies, panoramic radiographs and models, the anchorage loss after initial maxillary canine retraction between two groups. Eighteen patients were selected, then randomly divided into two groups of 9 individuals each (A and B), and elected for orthodontic treatment in the Faculty of Dentistry of Araçatuba – UNESP, Orthodontics Department. Group A utilized mini-implant while group B utilized lingual button. For all patients, two teleradiographies (T1 and T2), two panoramic radiographs (P1 and P2) and two models (M1 and M2) were done. The first complementary exams were accomplished in the beginning (T1, P1 and M1) and the other in the end of the initial canine retraction (T2, P2, and M2). The second phase was elected (initial canine retraction) due to the great anchorage loss that exists in this treatment stage. All measurements were tabulated and submitted to statistical analysis. For the comparison between the stages “Beginning” and “After”, a paired t test was used. For the comparison between the mini-implant and lingual button groups, a Student’s t test for independent measurements was used. In all tests, a significance level of 5% (p<0,05) was adopted. All statistical calculations... (Complete abstract click electronic access below)
444

Avaliação do tratamento ortodôntico precoce da classe II, 1ª divisão, subdivisão

Grehs, Renésio Armindo [UNESP] 01 July 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:33:23Z (GMT). No. of bitstreams: 0 Previous issue date: 2004-07-01Bitstream added on 2014-06-13T20:44:49Z : No. of bitstreams: 1 grehs_ra_dr_arafo.pdf: 1198034 bytes, checksum: 2be2545e38cb4c3436e2561d7816c44b (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Esta pesquisa de natureza prospectiva foi realizada com base numa amostra não casualizada constituída de 23 indivíduos portadores de má oclusão Classe II, 1ª Divisão, Subdivisão na fase da dentadura mista. O propósito do estudo foi avaliar um novo procedimento para o tratamento precoce da Classe II Subdivisão com envolvimento mandibular, método proposto por Sakima 85 em 2003. A amostra foi dividida em: Grupo 1 - Portadores de má oclusão Classe II Subdivisão com mordida cruzada posterior unilateral (D) ou (E) e Grupo 2 - Portadores de má oclusão Classe II Subdivisão sem cruzamento. Todos os indivíduos foram submetidos a tratamento ortodôntico de interceptação para correção da subdivisão, sendo que o Grupo 1 teve procedimento prévio para descruzamento da mordida cruzada posterior unilateral (MCPU). A avaliação dos resultados foi realizada mediante tomada de radiografias extra-orais Submento-vertex, os cefalogramas foram traçados e os dados compilados para análise em computador. Os traçados cefalométricos obtidos das imagens radiográficas da Submento-vertex (SMV) foram digitalizados no programa Radiocef. Os dados analisados, submetidos à metodologia estatística e os resultados discutidos. O método estatístico empregado, além da utilização da média e desvio padrão, contou com o Teste t de Student, Teste F de Snedecor e probabilidade p, utilizou-se também o teste não paramétrico de Mann-Whitney-Wilcoxon, os dados estatísticos foram utilizados para avaliar os resultados do tratamento ortodôntico realizado. Após a discussão dos resultados, concluiu-se que: 1)Houve presença de rotação mandibular significante para ambos os grupos estudados quando relacionada maxila e mandíbula; 2) A evolução dos grupos estudados foi semelhante tanto clínica como cefalométrica; 3) Os movimentos dentários constatados melhoram o... . / The purpose of this study was to evaluate a new approach to the early orthodontic treatment of Class II, division 1, subdivision, in the mixed dentition and determined the utility of approach. The sample consisted of 23 subjects divided in two groups (group 1 and group 2). The average was 9.3 years considered in both groups. Measurements were obtained with the use of Submento-vertex Cephalometric Radiographs. The Submento-vertex Radiographs symmetry was assessed by measuring the differences in the spatial positions of dental and Skeletal landmarks between right and left side, determined asymmetric (A) and normal (N) sides. The Angle's 2 Class II subdivision was evaluated in the mixed dentition. Statistic method was based on the skewness statistics, the distributions were normal, allowing means and standard deviations to be used to describe central tendencies and dispersion. We also used the Student t test, the Snedecor p test and Mann-Whitney-Wilcoxon tests were used to statistically comparation.The results showed lower jaw replacement and dento-alveolar displacement in order to correct this malocclusion. The conclusions about the present study were: 1) There was significant mandibular rotation from the asymmetric side to the symmetric side in the two groups when maxilar and mandibular relation was investigated; 2) The two groups evolution was clinical and cephalometrical similar; 3) The teeth movements provide evidence to better relation of the occlusion; 4) The midline line of the teeth has a clinically consistent to normalization and this can better investigated with other evaluation methods.
445

Avaliação clínica e microbiológica periodontal de crianças e adolescentes sob terapia ortodôntica com aparelhos fixos ou removíveis

Rêgo, Rodrigo Otávio Citó César [UNESP] 06 October 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:33:28Z (GMT). No. of bitstreams: 0 Previous issue date: 2004-10-06Bitstream added on 2014-06-13T19:04:26Z : No. of bitstreams: 1 rego_rocc_dr_arafo.pdf: 771295 bytes, checksum: 5b0351282506ff58004e2c6aac89a587 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / O objetivo deste estudo foi avaliar os parâmetros clínicos e microbiológicos periodontais de crianças e adolescentes sob terapia ortodôntica com aparelho fixo ou removíveis. Trinta indivíduos (14,5l1,7 anos - Grupo FIX) que utilizavam aparelhos fixos e 18 que utilizavam aparelho extra bucal removível ou placa de Hawley há pelo menos 6 meses (9,6 l 1,5 anos - Grupo REM) foram comparados a dois grupos controle, constituídos por indivíduos da mesma idade (14,2 l 1,7 anos - Grupo C-FIX e 9,3 l 1,9 anos - Grupo C-REM) que não utlizavam esses dispositivos. Foi analisada a presença de placa bacteriana visível (IP), sangramento gengival (IG), profundidade de sondagem (PS) e perda de inserção clínica (PIC). Amostras de placa bacteriana subgengival foram coletadas e analisadas por meio de sondas de oligonucleotídeos para A. actinomycetemcomitans (Aa), C. rectus, Capnocytophaga sp. E. corrodens, F. nucleatum, F. vincentii, M. micros, Neisseriaceae., P. gingivalis, P. intermedia, espiroquetas, T. forsythensis e Treponema sp. Diferenças significantes (p<0,05) foram observadas entre os grupos FIX e C-FIX quanto aos parâmetros IP (66,8% e 47,7%), IG (43% e 15,6%), e para as prevalências de todas as bactérias avaliadas, exceto as da familia Neisseriaceae. Entre dentes bandados e seus análogos no grupo controle foram encontradas diferenças significantes para os parâmetros PV (80,3% e 58,8%), SM (64,3% e 20,6%) e PS (2,9 mm e 2,5 mm), respectivamente. Entre os grupos REM e C-REM, essas diferenças também foram observadas para IP (58,7% e 14,3%) e IG (19,8% e 8,8%) e para as prevalências de Aa, C. rectus, E. corrodens, Neisseriaceae e espiroquetas. Entre os dentes retentores de grampo e seus análogos no grupo controle verificou-se diferenças significantes para IP (77,8% e 31,3%). Não foi verificado aumento da PS associado a PIC. Também foi avaliada a... . / The purpose of this study was to compare clinical and microbiological parameters in children and adolescents with and without fixed or removable orthodontic appliances. Thirty subjects (mean age 14.5l1.7 years) treated with fixed appliances and 18 treated with removable appliances for at least 6 months were selected as test groups, FIX and REM, respectively. The control groups were comprised of 30 subjects (mean age 14.2l1.7 years - Group C-FIX) and 18 subjects (mean age 9.3l1.9 years - Group C-REM) that did not receive orthodontic treatment. Clinical evaluations were made for plaque index (PI), gingival index (GI), probing depth (PD) and clinical attachment loss (CAL). Subgingival plaque samples were collected from the patients and analyzed by oligonucleotide probes for the presence of A. actinomycetemcomitans (Aa), C. rectus, Capnocytophaga sp. E. corrodens, F. nucleatum, F. vincentii, M. micros, Neisseriaceae., P. gingivalis, P. intermedia, spirochetes, T. forsythensis and Treponema sp. Additionally, two subgingival dental plaque samples from one subject of each test group were further analyzed by cloning and sequencing the amplified 16S rDNA. Significant differences were noted between FIX and C-FIX for PI (66.8% versus 47.7%), GI (43.8% versus 15.6%) and between the banded teeth in the FIX group and the analogous teeth in the C-FIX group for PI (80.3% versus 58.8%), GI (64.3% versus 20.6%) and PD (2.9 mm versus 2.5 mm). Significant differences were noted between FIX and C-FIX for all targeted bacteria but Neisseriaceae. Results: Significant differences were also noted between REM and C-REM for PI (58.7% versus 14.3%) and GI (19.8% versus 8.8%) and between the clasped teeth in the test group and the analogous teeth in the control group for PI (77.8% versus 31.3%). Significant differences were noted between the REM and C-REM for Aa... (Complete abstract, click electronic address below).
446

Verificação da relação entre proporção áurea e estética facial, antes e depois do tratamento ortodôntico, utilizando radiografias cefalométricas laterais e fotograficas

Takeshita, Wilton Mitsunari [UNESP] 12 December 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:10Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-12-12Bitstream added on 2014-06-13T20:06:38Z : No. of bitstreams: 1 takeshita_wm_dr_sjc.pdf: 1623821 bytes, checksum: 77600aceb6708cfaa2416694760f91d9 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A beleza está ligada a proporcionalidade e esta constante proporção nos dá a impressão de orientar o crescimento, a harmonia, a reprodução e a estabilidade das formas na natureza, o que vêm sendo constatados na história por estudiosos como: filósofos, matemáticos, escultores, pintores, arquitetos e Ortodontistas. Pitágoras, um estudioso da matemática, estabeleceu as proporções a partir dos padrões de beleza e harmonia estética. Sendo denominada como proporção áurea A partir desse pensamento advém o fato da utilização da proporção áurea na avaliação de estruturas craniofaciais pretendendo gerar uma análise individualizada, trazendo para cada indivíduo proporções obtidas com base em suas próprias medidas. Assim foi propósito no presente trabalho de pesquisa verificar por meio de radiografias cefalométricas laterais e fotografias frontais e laterais a relação entre a proporção áurea e estética facial antes e depois do tratamento ortodôntico. Foram utilizadas radiografias cefalométricas laterais, fotografias frontais e de perfil de 67 indivíduos antes e depois do tratamento ortodôntico. Foi desenvolvido um programa de cefalometria em Delphi 7.0, contendo a análise cefalométrica deste trabalho de pesquisa. Concluímos: no Grupo 1(melhora após o tratamento ortodôntico) as razões A-Pog/V1S-C1MS, Ena-Enp/V1S-C1MS e V1S-C1MS/C1MS-DM16 diferiram da forma estatisticamente significante comparando antes e depois do tratamento ortodôntico. A razão V1S-C1MS/C1MS-DM16 antes do tratamento não se apresentava em proporção áurea e depois do tratamento passou a se apresentar em proporção áurea. No grupo 2 (não ocorreu melhora após o tratamento) apenas a razão N-Ena/V1S-DM16 diferiru de forma estatisticamente significante comparando antes e depois do tratamento. / The beauty is connected to the proportionality and this constant proportion gives us the impression of guiding the growth, the harmony, the reproduction and the stability of the forms in the nature, what is being evidenced in history for studious as: philosophers, mathematicians, sculptors, painters, architects and Orthodontists. Pithagoras, a mathematics studious, established the proportions from the beauty standards and aesthetic harmony. It was designated as golden proportion. From this thought comes the fact of the use of the golden proportion in the evaluation of cranium facial structures intending to generate an individualized analysis, bringing for each person proportions based in it own measures. It was the purpose in the present research work to verify by lateral cephalometry radiographies, frontals and laterals photographs the relation between golden proportion and aesthetic facial before and after the orthodontic treatment. It was used lateral cephalometry radiographies, frontal and lateral photographs of 67 individuals before and after the orthodontic treatment. It was developed a program of cephalometry in Delphi 7.0, having the cephalometry analysis of this research work. It was concluded: in the Group 1 (improvement after the orthodontic treatment) the ratios A-Pog/V1S-C1MS, Ena-Enp/V1SC1MS and V1S-C1MS/C1MS-DM16 had differed from the statically significant form comparing before and after the orthodontic treatment. The ratio V1SC1MS/ C1MS-DM16 before the treatment was not presented in aureate proportion and after the treatment becomes to present itself in aureate proportion. In group 2 (no improvement after the treatment) only the ratio N-Ena/V1S-DM16 had differed from the statically significant form comparing before and after the treatment. The ratio A-Pog/V1S-DM16, before the treatment, was presented in golden proportion before the treatment and after the treatment it was not presented in golden proportion.
447

Efeito da corticotomia e decorticalização na movimentação ortodôntica : estudo em ratos /

Zuppardo, Marcelo Lelis. January 2018 (has links)
Orientador: Maria Aparecida Neves Jardini / Coorientador: Milton Santamaria Junior / Banca: Lúcio Pereira de Castro Lopes / Banca: Mariellen Longo / Banca: Camila Borges Fernandes / Banca: Fabio da Silva Matuda / Resumo: Este estudo comparou dois protocolos cirúrgicos, corticotomia e corticotomia com decorticalização, em ratos para verificar alteração na movimentação ortodôntica convencional. 60 animais foram divididos aleatoriamente: Grupo controle (GC) - movimentação ortodôntica convencional; Grupo 1 (G1) -movimentação ortodôntica e corticotomia; Grupo 2 (G2) - movimentação ortodôntica com corticotomia e decorticalização. Os animais foram eutanasiados após 7 e 14 dias. No G1 e G2 houve uma maior movimentação ortodôntica comparado aos animais do GC aos 14 dias (p = 0,009 e 0,016) com uma maior área radiográfica interradicular, menor volume ósseo/volume total, menor área final e menor porcentagem de osso. Aos 7 dias os animais do G2 apresentaram menor volume de osso/volume total comparado com GC e aos 14 dias os animais do G2 apresentaram uma menor medida linear da crista óssea comparado com o GC. Os animais do GC aos 14 dias apresentaram uma maior área final comparado aos 7 dias, enquanto o G2 apresentou maior número de células TRAP positivas tanto aos 7 quanto aos 14 dias comparado com o G1. Na análise histológica aos 7 dias houve frequente reabsorção radicular inicial geralmente associada às áreas de hialinização e aos 14 dias, presença do infiltrado inflamatório e com menor ocorrência de áreas hialinas. O padrão de reabsorção radicular iniciado no 7º dia de movimento e consolidado no 14º dia. Concluímos que a corticotomia acelera a movimentação ortodôntica em 14 dias independente da magni... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This study compared two surgical protocols, corticotomy and decorticalization corticotomy, in rats to verify alteration in conventional orthodontic movement. 60 animals were randomly divided: Group 1 (G1) orthodontic movement and corticotomy, and Group 2 (G2) orthodontic movement with corticotomy and decorticalization. The animals were euthanized after 7 and 14 days. In G1 and G2, there was a greater orthodontic movement compared to CG animals at 14 days (p = 0.009 and 0.016) with a higher interradicular radiographic area, lower bone volume / total volume, lower final area and lower percentage of bone. At 7 days the G2 animals presented lower bone volume / total volume compared to CG and at 14 days G2 animals presented a smaller linear measure of bone crest compared to CG. GC animals at 14 days presented a larger final area compared to 7 days, while G2 presented a higher number of TRAP cells positive at 7 and 14 days compared to G1. In the histological analysis at 7 days, there was frequent initial root resorption generally associated with hyalinization areas and at 14 days, presence of inflammatory infiltrate and less occurrence of hyaline areas. The root resorption pattern started on day 7 of movement and was consolidated on the 14th day. We conclude that corticotomy accelerates orthodontic movement in 14 days regardless of the magnitude of the surgical injury / Doutor
448

Apresentação de um método experimental de traumatismo dentoalveolar em ratos para realização de experimentos de movimentação dentária induzida /

Pereira, Alex Luiz Pozzobon. January 2005 (has links)
Resumo: Este trabalho tem como finalidade apresentar um método para estudo do traumatismo dentoalveolar, utilizando um dispositivo capaz de promover a mesma intensidade e sentido de aplicação da força sobre molares de ratos, e dessa forma, ser utilizado como um modelo de estudo experimental na movimentação dentária induzida de dentes previamente traumatizados. Para a realização desse traumatismo foi utilizado um tensiômetro, com uma das suas extremidades adaptada para exercer um impacto sobre o primeiro molar superior. O tensiômetro foi fixado em um suporte de metal com a finalidade de padronizar a direção da aplicação da força e posicionar corretamente sua extremidade sobre o primeiro molar superior. Aplicou-se um trauma no sentido ocluso-gengival de 600 gramas sobre a região oclusal do primeiro molar superior direito de 10 ratos, correspondente à aproximadamente 600cN. Em seguida os animais foram mortos e a maxila direita coletada para análise microscópica do tecido pulpar e o ligamento periodontal da raiz mesial do primeiro molar superior. A análise microscópica demonstrou que a força de 600cN não se mostrou efetiva para promover alterações no ligamento periodontal, polpa e raiz. Por outro lado, demonstrou que um trauma de intensidade menor como a concussão, não promove alterações no ligamento periodontal, e por sua vez não representa um problema para o ortodontista. / Abstract: This study has as purpose to present a method for study of the dentoalveolar traumatism, using a device capable to promote a traumatism maintaining the same intensity and sense of application of the force on molars of rats, and in that way, to be used as a method of experimental study in the induced movement of teeth previously traumatized. For the accomplishment of that traumatism a gauge was used, with one of their extremities adapted to exercise an impact on the first superior molar. The gauge was fastened in a metal support with the purpose of to standardize the direction of the application of the force and to position his extremity correctly adapted on the first superior molar. A injury was applied in the ocluso-gingival sense on the vestibular crest of the first right superior molar of 10 rats with force of 600 grams, corresponding to the approximately 600cN. Soon afterwards the animals were died and the right maxillary bone collected for histological analysis of the pulpal and the periodontal ligament of the root mesial of the first superior molar. The histological analysis demonstrated that the force of 600cN was not shown executes to promote alterations in the periodontal ligament, pulp and root, on the other hand it demonstrated that a trauma of smaller intensity as the concussion, doesn't promote alterations in the periodontal ligament, and for his time it doesn't represent a problem for the orthodontist. / Orientador: Marcos Rogério de Mendonça / Coorientador: Celso Koogi Sonoda / Banca: Osmar Aparecido Cuoghi / Banca: Renato Rodrigues de Almeida / Mestre
449

Estudo comparativo da retenção das bandas ortodônticas Grip Tite, convencional e convencional com a superfície interna microjateada por óxido de alumínio

Vargas, Deborah Bayer Ferraz [UNESP] January 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:54Z (GMT). No. of bitstreams: 0 Previous issue date: 2007Bitstream added on 2014-06-13T18:56:43Z : No. of bitstreams: 1 vargas_dbf_me_arafo.pdf: 680704 bytes, checksum: b86da5b28576f3b91eb2292fc618c8b8 (MD5) / Universidade Estadual Paulista (UNESP) / O objetivo do presente trabalho foi avaliar in vitro, por meio de um ensaio mecânico, a força necessária para a remoção das bandas ortodônticas Grip Tite (C), Convencional (A) e banda Convencional com a superfície interna microjateada por óxido de alumínio (B). Também analisar visualmente a quantidade de cimento residual, e classificar usando uma escala de incrementos a 25%. Após, verificar, por meio de MEV, a superfície com melhores características para a retenção. Os resultados obtidos mostraram que a média de carga do Grupo B, bandas microjateadas internamente por óxido de alumínio, foi significantemente maior que as médias dos Grupos A, bandas Convencionais, e C, bandas Grip Tite. Quanto a quantidade de cimento remanescente nas bandas, o Grupo B apresentou 100% das bandas com índice 4, indicando a presença de mais de 75% de cimento residual nas bandas, enquanto que nos Grupos A e C, houve a predominância do índice 1, indicativo de menos de 25% de cimento residual nas bandas, sem diferença significativa entre esses dois grupos. Os resultados foram confirmados pela MEV, onde observou-se uma superfície com melhores características para a retenção do cimento nas bandas onde foi realizado o processo de microjateamento. Conclui-se que o processo de microjateamento por óxido de alumínio, na superfície interna das bandas convencionais, aumenta a força necessária para a remoção das bandas e aumenta a quantidade de cimento residual preso à superfície da banda. Quando analisada pela MEV, essa superfície apresenta-se como a mais áspera e rugosa, com a maior quantidade de cimento de ionômero de vidro aderido à banda. / The purpose of this study was to evaluate in vitro, the necessary force for the removal of Grip Tite, Conventional and Sandblasted orthodontics molar bands, as well as, to analyze and to classify the amount of residual cement in the internal surface of these bands. After that, checking through scanning electron microscopy, the surface with better characteristics for the retention. The obtained results showed that the load average of the group B, Sandblasted bands, was significantly higher than the group A, Conventional bands, and C, Grip Tite bands. Observing the amount of remaining cement in the bands, group B presented 100% of the bands with index 4, indicating the presence of more than 75% of residual cement in the bands, while in the groups A and C, had the predominance of index 1, indicative of less than 25% of residual cement in the bands, without significant difference between these two groups. The results were confirmed by the scanning electronic microscopy, where the surface with better characteristics for the retention of the cement was observed, in the bands where the sandblasted process was carried through. It was concluded that the process of sandblasted, in the internal surface of the conventional bands, increases the necessary force for the removal of the bands and increases the amount of residual cement in the internal surface of the band. When analyzed by the scanning electronic microscopy, this surface appeared rougher and corrugated, with great amount of glass ionomer cement adhered to the band.
450

Avaliação da resistência ao arrancamento de mini-implantes ortodônticos: estudo laboratorial

Gouvêa, Carla Corrêa Mendes [UNESP] 07 October 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:54Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-10-07Bitstream added on 2014-06-13T20:17:27Z : No. of bitstreams: 1 gouvea_ccm_me_araca.pdf: 929518 bytes, checksum: 1d39d7891d1bd1d3169ca5b03ea750f2 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação para o Desenvolvimento da UNESP (FUNDUNESP) / Sin Implantes / Objetivo: comparar, por meio do teste de arrancamento, a estabilidade primária de mini-implantes com diâmetro e comprimento diferentes inseridos em osso artificial. Material e método: foram utilizados 80 mini-implantes da marca SIN (Sistema de Implante) com 1mm de perfil transmucoso e divididos em 4 grupos: grupo I - mini-implantes de 1,4 mm de diâmetro e 6 mm de comprimento ; o grupo II - mini-implantes de 1,4 mm de diâmetro e 8 mm de comprimento; o grupo III - mini-implantes de 1,6 mm de diâmetro e 6 mm de comprimento; grupo IV - mini-implantes de 1,6 mm de diâmetro e 8 mm de comprimento. Os mini-implantes foram inseridos em bloco de osso artificial Sawbones (SAWBONES Pacific Research Laboratories) e submetidos ao teste de arrancamento na máquina de ensaio universal – EMIC. Resultados: os valores médios de força de arrancamento dos mini-implantes oscilaram entre 621.995N a 738.220N. A Análise de Variância mostrou que houve diferença estatisticamente significante entre os grupos (p<0.05). Na comparação entre os grupos houve igualdade entre os grupos I e III. Todas as demais comparações foram estatisticamente diferentes. Conclusões: em relação à estabilidade primária, constatou-se que os grupos I e III foram iguais, enquanto que, todos os demais apresentaram diferença na estabilidade / Objective: to compare, by means of the pullout test, the primary stability of mini-implants with different diameter and length placed in artificial bone. Method: 80 mini-implants Sin (Implant System) with 1mm transmucosal profile and divided into four groups: Group I - mini-implants with diameter of 1.4mm and 6 mm of long; Group II - mini-implants with diameter of 1.4mm and 8 mm long; Group III - mini-implants with diameter of 1.6mm and 6 mm of long; Group IV - mini-implants with a diameter of 1.6mm and 8 mm of long. Mini-implants were inserted in block artificial bone Sawbones (Sawbones Pacific Research Laboratories) and tested in pullout universal testing machine – EMIC. Results: the mean pullout strength of mini-implants ranged from 621.995 to 738,220 N. Analysis of Variance showed that there was a statistically significant difference between the groups (p <0.05). Comparing the groups were only equality between groups I (mini-implants 1.4 Ø x 6 mm) and III (mini-implants Ø 1.6 x 6mm). All other comparisons are statistically different. Conclusions: relative primary stability, it was found that the groups I and III were similar, whereas all others show differences in stability

Page generated in 0.083 seconds