Spelling suggestions: "subject:"orthopedic"" "subject:"orthopaedic""
81 |
Axial pull-out strength of 3.5 cortical and 4.0 cancellous bone screws placed in canine proximal tibias using manual and power tappingDemko, Jennifer Lynn, January 2008 (has links)
Thesis (M.S.)--Mississippi State University. Department of Clinical Sciences, College of Veterinary Medicine. / Title from title screen. Includes bibliographical references.
|
82 |
Stress Reactions of Division-I Track AthletesSkarda, Laura Elizabeth 01 January 2012 (has links)
Problem: Track and field athletes, along with cross-country athletes have multiple and back to back seasons, creating overuse injuries. Stress fractures or stress reactions to the bone are the overuse injuries focused on in this study and literature review. There is a lack of information in the literature regarding stress reactions. Purpose: The goal of the study is to understand more information about stress reactions to bone and possibly increase the knowledge of health care professionals. Methods: Three case studies were examined through pre-existing medical chart notes and athletic trainer's notes regarding the stress reactions. A literature review was also performed to provide further information about stress fractures and stress reactions. Conclusions: There are multiple risk factors for stress injuries. All three of the athletes in the case studies are female, which is found to be a risk factor. Many risk factors need more studies to provide support. Magnetic Resonance Imaging (MRI) was obtained in all three case studies where there was found to be a stress reaction. These three females also had a recent increase in activity level and had similar symptoms to each other and what is found in the literature.
|
83 |
Lives and limbs : re-membering Robert Jones : a biographyWhiteley, Joanna January 2010 (has links)
This is a biography of Robert Jones, 1857-1933. He was a surgeon, and is credited with bringing orthopaedics from its quack past into its scientific present. This work explores Jones’ life and times, and examines whether he is entitled to the epithet ‘father of orthopaedics’. It looks at the history of bonesetting, the influences on Jones’ development and medical training, and some key moments in his career – notably his involvement in the building of the Manchester Ship Canal, the planning of Heswall Children’s Hospital, and the Great War. It argues that although there are other medical men who could have been credited with fathering orthopaedics, he is indeed the father – at least of orthopaedics in Britain, if not internationally. This version of Jones’ life begins with something of his biographer’s journey, before it explores what and who influenced Jones, and in turn what his legacy has been to the medical profession. The accompanying Critical Commentary explores whether or not it is possible to offer a definition of biography as a genre in the light of its history and purpose. It examines critical views, considers the mythology that grows up around historical figures, and also explains the rationale for the structure chosen for organising the material presented in this new biography of Robert Jones, Live and Limbs: Re-membering Robert Jones.
|
84 |
Matriz óssea desmineralizada caprina (MODc) na reparação de falhas ósseas não-críticas em tíbias de coelhos /Santos, Felipe Rocha dos. January 2019 (has links)
Orientador: Bruno Watanabe Minto / Banca: Luis Gustavo Gosuen Gonçalves Dias / Banca: Fernando Yoiti Kitamura Kawamoto / Resumo: Objetivou-se neste estudo avaliar a matriz óssea desmineralizada caprina como xenoenxerto em falhas ósseas tibiais de coelhos. Foram utilizados 24 coelhos fêmeas, adultos da raça Nova Zelândia. Uma falha circular monocortical de 6 mm de diâmetro foi criada em ambas as tíbias, no terço proximal da superfície medial. A lesão da tíbia esquerda foi preenchida com 70mg de matriz óssea desmineralizada caprina, enquanto que a direita correspondeu ao controle. Nos períodos pós-operatórios de 15, 30, 60 e 90 dias, os 6 animais de cada grupo foram submetidos à eutanásia e amostras de tíbia proximal foram coletadas. As amostras foram escaneadas por meio de microtomografia computadorizada helicoidal. Analisou-se as características macroscópicas do reparo ósseo, o padrão de preenchimento trabecular e formação de tecido ósseo intralesional. Foram observadas diferenças estatisticamente significativas entre os grupos, para os parâmetros volume ósseo e na relação entre volume ósseo e volume total nos tempos 15, 30 e 90 dias, com maior produção óssea obtida do grupo controle. Evidenciou-se também superioridade estatística do grupo controle em relação ao grupo matriz, para as variáveis superfície óssea, relação entre superfície óssea e superfície total e número de trabéculas, nos tempos 15 e 90 dias, indicando maior superfície óssea do tecido de reparo no grupo controle. A matriz óssea desmineralizada caprina demonstrou ser biotolerável e segura em coelhos, durante 90 dias, comprovando por meio... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The objective of this study was to evaluate the demineralized goat bone matrix as xenograft in tibial bone defects of rabbits. Twenty-four female rabbits, New Zealand adults, were used. A circular monocortical defect of 6 mm in diameter was created in the form of tibias, without proximal third of the medial surface. The case of the boundary case of the case of the demineralized caprine, while a corresponding right to control. On the postoperative days of 15, 30, 60 and 90 days, the six animals were submitted to euthanasia and proximal tibia samples were collected. The samples were scanned by computerized helical microtomography. Analyzed as macroscopic of bone repair, trabecular filling pattern and intralesional bone formation. Statistically significant differences were observed between the groups, so that the volumes were adjusted to the variable between volume and total volume at times 15, 30 and 90 days, with higher bone production in the control group. It was also evidenced the statistical superiority of the control group in relation to the set of matrices, such as the temperature in bone ground, the relation between the bone surface and the total surface and the number of trabeculae, in the 15 and 90 days, control. The demineralized bone matrix demonstrated to be biotolerable and safe in systems, during 90 days, proved by computer microtomography, the beginning of the system installation in 30 days after implantation, as well as a bone bridge formation at 60 days. / Mestre
|
85 |
Relação interarcos em pacientes com FLPUC submetidos à queiloplastia neonatal versus queiloplastia em fase convencional com e sem ortopedia infantil / Dental arch relationships in patients with unilateral cleft lip and palate (UCLP) undergoing early lip repair versus late repair with and without infant orthopedicsGalassi, Thalita Varela 05 August 2016 (has links)
Objetivo: comparar a relação interarcos de 112 indivíduos com FLPUC submetidos a queiloplastia neonatal versus em fase convencional, com e sem ortopedia infantil, aplicando-se o índice oclusal de Goslon/5 anos em fotografias intrabucais, obtidas entre 6 e 12 anos de idade. Desenho: estudo retrospectivo de coorte. Local: dois centros de reabilitação do Brasil. Participantes: três grupos tratados com distintos protocolos: grupo I: queiloplastia neonatal (1 a 15 dias) + OI (ortopedia Infantil); grupo II: queiloplastia (3 a 12 meses) + OI; grupo III: queiloplastia (3 a 6 meses), sem OI. Intervenções: o grupo I (n=35) e grupo III (n=58) foram operados pelo mesmo cirurgião, enquanto que o grupo II (n=19) por 4 cirurgiões. Método: para comparação entre os grupos foi utilizado o teste qui-quadrado e para a comparação dos índices oclusais médio intergrupos foi aplicado o ANOVA, Kruskal Wallis (p<0,05). Resultados: a concordância interexaminadores (acima 0,70) e intra (acima de 0,60) foi dada pela estatística kappa. O grupo I apresentou maior percentual de índice 5. O grupo II apresentou o maior percentual de índice 1 e o grupo III apresentou o menor percentual de índice 5 (p=0,029). As estatísticas com os índices agrupados em 1+2 e 4+5 não demonstraram diferenças entre os 3 grupos (p=0,142). O índice oclusal médio em cada grupo apresentou diferenças significativas entre os grupos I (4,0) e III (3,0) (p=0,022). Conclusão: os resultados demonstraram que em relação ao crescimento maxilomandibular, a queiloplastia em fase neonatal com OI (grupo I) apresentou-se menos favorável quando comparada aos outros dois grupos operados a partir dos três meses. O grupo II, operados mais tardiamente de lábio e palato com OI apresentou crescimento favorável enquanto que o grupo III sem OI presentou a menor quantidade de casos com prognóstico ortodôntico-cirúrgico. Considerando a variabilidade e limitações da amostra sugerimos mais trabalhos que envolvam centros que utilizam os protocolos com e sem ortopedia infantil, de preferência de forma prospectiva e randomizada. / Objective: to compare the outcomes of early versus conventional cheiloplasty with and without infant orthopedics (IO) by assessment of dental arch relationships in individuals with non-syndromic complete UCLP, analyzed by the occlusal index for intraoral photographs rating. Design: retrospective cohort study. Setting: two cleft palate centers from Brazil. Participants: three groups treated by different protocols, as follows; Group I: early cheiloplasty (1 to 15 days) + infant IO; Group II: cheiloplasty (3 to 12 months) + IO; Group III: cheiloplasty (3 to 6 months) without IO and palatoplasty (12 to 18 months). Interventions: Individuals in Group I (n=35) and Group III (n=58) were operated by a single surgeon each, while individuals in group II (n=19) were operated by 4 surgeons. The 112 intraoral photographs of individuals of all groups, obtained between 6 and 12 years of age, were assessed by the occlusal index. Main outcome measures: the groups were compared by the chi-square test, and the mean occlusal indices between groups were compared by ANOVA and Kruskal Wallis tests (p<0.05). Results: intrarater (above 0.70) and interrater (above 0.60) was performed by kappa statistics. Group I presented highest percentage of score 5, Group II exhibited highest percentage of score 1, and Group III presented the lowest percentage of score 5 (p=0.029). Analysis grouping scores 1+2 and 4+5 did not reveal statistically significant differences between the 3 groups (p=0.142). The mean occlusal index for each group showed significant differences between groups I (4.0) and III (3.0) (p=0.022). Conclusions: early cheiloplasty with IO (grupo I) was less favorable for maxilomandibular growth compared to the other two groups operated at later ages. Group II, comprising cheiloplasty and palatoplasty at later stages + IO exhibited favorable growth, while group III without IO showed the least amount of orthodontic surgical cases prognosis. Considering the variability and limitation of the present sample, further prospective and randomized studies are warranted.
|
86 |
Avaliação biomecânica dos ossos III/IV metacarpianos com falhas ósseas induzidas experimentalmente, tratados com mantas ósseas a base de quitosana, hidroxiapatita e colágeno, em ovinos / Biomechanical evaluation of III/IV metacarpal bones with bone defects induced experimentally in sheep treated with chitosan, collagen and hydroxyapatite compositeAlmeida, Luís Eduardo Stevanato de 26 June 2015 (has links)
Nos equinos as fraturas geralmente são de alta energia provocando perda do tecido ósseo. Estas lesões do tecido ósseo ocorrem quando suas propriedades de resistência e rigidez são ultrapassadas. Devido a perda de tecido ósseo diversos métodos são utilizados para corrigir os defeitos ósseos, tanto em ortopedia humana, quanto na medicina veterinária, porém os resultados muitas vezes não são satisfatórios. O desenvolvimento de compostos a base colágeno, quitosana e hidroxiapatita deu-se devido a busca na melhora do comportamento mecânico e biológico dos enxertos. O objetivo deste estudo foi avaliar o comportamento biomecânico do osso III/IV metacarpianos de ovinos após a implantação de compósito de quitosana, hidroxiapatita e colágeno. Foi utilizado seis ovinos fêmeas da raça Santa Inês, os quais foram submetidos à ostectomias unicorticais de cinco milímetros de diâmetro na região média da superfície dorsal do III/IV metacarpianos. Posteriormente, através de sorteio, foi implantado o compósito de quitosana, colágeno e hidroxiapatita em um membro torácico. No membro contralateral foi reproduzida a mesma técnica, porém foi mantido como controle, não sendo preenchido com o compósito. Todos os animais foram submetidos à avaliação física diária. Após 180 dias da criação da falha, os ovinos foram eutanasiados com protocolo autorizado pela Comissão de Ética no Uso de Animais. Os ossos foram dissecados e armazenados á 20º C. Após o descongelamento completo, as amostras foram submetidas a ensaio de flexão em três pontos realizado em máquina universal de ensaios mecânicos KRATOS®, modelo KE3000MP, software: TRACOMP W95. Os ossos foram posicionados com sua superfície palmar (mais plana) apoiada sobre duas bases cônicas distantes 5 cm entre sí, de modo que a falha óssea ficasse posicionada à mesma distância entre as bases. A carga foi aplicada na superfície dorsal por um atuador cônico no ponto médio do osso, onde foram criadas as falhas ósseas, com velocidade de deslocamento de 5 milímetros por minuto até o momento da fratura do osso. Durante o ensaio mecânico o software gerou gráficos de força x deformação, de onde foram calculadas as seguintes propriedades biomecânicas: força máxima, rigidez, momento e deformação máxima. Através da análise estatística não houve diferença estatísticas na análise da rigidez, força máxima, momento e deformação máxima para ambos os grupos. Com estes resultados podemos concluir que o compósito de quitosana, hidroxiapatita e colágeno não interferiu na consolidação óssea de III/IV metacarpianos de ovinos após 180 dias da implantação. / In equines, the fractures are usually of high energy causing loss of bone tissue. These bone tissue injuries occur when its properties of strength and rigidity are outdated. Due to bone loss, various methods are used to correct the bone defects, both in human and in orthopedic veterinary medicine, but the results often are not satisfactory. The development of chitosan, collagen and hydroxyapatite composite came about due to search the improvement of the mechanical behaviour and biological grafts. The objective of this study was to evaluate the biomechanical behavior of the III/IV metacarpal bone of sheep after the implantation of chitosan, collagen and hydroxyapatite composite. Six healthy female sheep Santa Inês breed were submitted to bilateral unicortical ostectomy (five mm/diameter) on the dorsal aspect of the III/IV metacarpal bone. One front limb was randomly selected for composite implatation. At the contralateral limb was reproduced the same technique, but was kept as control, and are not filled with composite. The animals were submitted to daily physical examination during 180-day follow-up period. After 180 days of failure creation, the animals were euthanized with protocol approved by the Animal Ethics Committee. The bones were dissected and stored at -20º C. After complete thawing, samples were subjected to bending test on three points held in universal testing machine mechanics KRATOS®, model KE3000MP, software: TRACOMP-W95. The bones were positioned with its palmar surface (flatter) supported on two tapered bases 5 cm distant from each other, so that the bone gap was positioned at the same distance between the bases. Load was applied on the dorsal surface by a tapered actuator at the midpoint of the bone, where bone defects were set up, with a speed of displacement of 5 mm per minute until the time of bone fracture. During the mechanical test the software generated graphs of force x deformation, where the following biomechanical properties were calculated: maximum strength, rigidity, moment and maximum deformation. Through statistical analysis, there was no difference in the analysis of statistics, maximum strength, rigidity and maximum deformation for both groups. With the results of this research, it can be concluded that the composite did not interfere in biomechanical characteristics of the metacarpal III/IV bone after 180 days of deployment
|
87 |
Avaliação estrutural do osso terceiro metacarpiano equino frente à implantação de biopolímero à base de mamona / Structural evaluation of the third metacarpal bone against the implantation of biopolymer based on castor oilSelim, Mariana Baroni 23 January 2014 (has links)
Uma série de novas estratégias vem sendo desenvolvidas com o objetivo de otimizar a reparação óssea, pois os métodos atualmente disponíveis em ortopedia humana e veterinária não apresentam resultados plenamente satisfatórios. Inúmeros pesquisadores dedicam-se ao desenvolvimento e estudo da compatibilidade de novos implantes com o propósito de acelerar a reparação óssea. O polímero a base de óleo de mamona tem chamado atenção para a sua aplicação como substituto ósseo, pois é um produto natural, biocompatível e com propriedades estruturais semelhantes às do tecido ósseo. Seis equinos foram submetidos à ostectomia na superfície diafisária dorsal de seus terceiros metacarpianos. Uma das falhas ósseas foi preenchida com o polímero a base de mamona e o outra, no membro contralateral permaneceu sem preenchimento, atuando como controle. Os animais foram acompanhados por um período de 120 dias após o procedimento através de monitoramento radiográfico da densidade óssea. Após este período, realizou-se biópsia para avaliação histológica por microscopias de luz e eletrônica de varredura. A densitometria óptica revelou valores médios de 14,17mmAl ± 1,722 e 16,33mmAl ±1,633 (p=0,027) para os grupos polímero e controle, respectivamente. A microscopia óptica de luz demonstrou maior porcentagem de tecido ósseo neoformado no grupo controle (50,15% ±14,83) quando comparado ao grupo polímero (26,94% ±12,06), com p0,0001. No entanto, a microscopia eletrônica de varredura permitiu observar que a qualidade do tecido ósseo formado na presença do biomaterial foi mantida. Além disso, não foram observadas reações adversas ao biomaterial, como a formação de tecido cicatricial ou reações de corpo estranho, levando a conclusão de que a poliuretana de óleo de mamona pode ser considerada adequada ao preenchimento de falhas ósseas em equinos, uma vez que desmonstrou compatibilidade e osteocondutividade. / A series of new strategies have been developed in order to optimize bone repair, because the methods currently available for human and veterinary orthopedics have no fully satisfactory results. Many researchers have dedicated to develop and study the compatibility of new implants in order to accelerate bone repair. The polymer of castor oil have drawn attention for its application as a bone substitute because it is a natural, biocompatible and have structural properties similar to bone tissue. Six horses were submited to ostectomy on the dorsal surface of its third metacarpal bone. One of the bone defects was filled with polymer of castor oil and the other remained unfilled, as a control group. The animals were followed for a period of 120 days after the procedure by monitoring radiographic bone density. After this period, a biopsy was performed for histological evaluation by light and scanning electron microscopy. The optical densitometry revealed medium values of 14.17mmAl ± 1.722 and 16.33mmAl ± 1.633 (p = 0.027) for the polymer and control groups, respectively. The light microscopy showed a higher percentage of new bone formation in the control group ( 50.15% ± 14.83 ) than in the polymer group ( 26.94 % ± 12.06 ) , with p 0.0001. However, scanning electron microscopy allowed to observe that the quality of bone formation tissue in the presence of biomaterial was maintained. Furthermore, there were no adverse reactions to biomaterial, such as scar formation or as a foreign body reaction, allowing to conclude that the polymer of castor oil can be considered suitable to fill bone defects in horses, since it demonstrated compatibility and osteoconductivity.
|
88 |
Estudo biomecânico comparativo entre novo sistema de bloqueio (PAX) e sistema convencional de bloqueio (Synthes) em ensaios de arrancamento e teste de quatro pontos / Biomechanical study comparing new locking plate system (PAX) and conventional locking plate system (Synthes) in pullout and four points test.Cavalcanti, Renato Albuquerque de Oliveira 20 January 2015 (has links)
Os materiais utilizados nas osteossínteses passam constantemente por avanços tecnológicos. Um dos mais recentes dispositivos é a chamada placa bloqueada, suas principais indicações são fraturas com alto grau de cominução, fraturas que não exigem uma redução anatômica, ossos osteopenicos, por exemplo, acometidos pela osteoporose, entre outras. Atualmente novos modelos de placas com bloqueio estão sendo desenvolvidos, onde a interface do parafuso e a placa são feito pela deformação do orifício, com a vantagem da instalação do parafuso em diversos ângulos. O presente projeto tem por objetivo estudar comparativamente a diferença entre os dois tipos de interface parafuso placa, como também realizar teste de quatro pontos comparando o sistema novo de bloqueio com o sistema convencional de bloqueio. Realizamos ensaios de arrancamento com sistema convencional de bloqueio (Synthes) e com o novo sistema de bloqueio (PAX) em parafusos 2,0mm; 2,4mm; 2,7mm e 3,5mm. Em todos os grupos testados o sistema convencional de bloqueio foi mais resistente e apresentou diferença significativa estatisticamente, teste de Mann- Witney (p< 0,05). Os valores de P obtidos foram: sistema 2.0mm p = 0,008; sistema 2.4 mm p= 0,008; sistema 2.7 mm p= 0,016; sistema 3.5 mm p= 0,008. No teste de 4 pontos utilizamos 20 placas da marca Synthes (sistema convencional de bloqueio) e 20 da marca PAX (novo sistema de bloqueio) e o sistema convencional de bloqueio se mostrou novamente mais resistente com diferença significativa. Os valores de P obtidos foram: sistema 2.0mm p = 0,008; sistema 2.4 mm p= 0,008; sistema 2.7 mm p= 0,008; sistema 3.5 mm p= 0,008. Conclui-se que o sistema convencional de bloqueio se mostrou mais resistente tanto no teste de arrancamento quanto no teste de flexão de quatro pontos. / The materials used in osteosynthesis constantly technological advances. One of the most recent devices is called the locking plate, its main indications are fractures with a high degree of comminution, fractures which do not require anatomical reduction, osteopenic bones, for example, affected by osteoporosis, among others. Currently new locking plate designs are being developed, where the screw interface and the plate are made by deformation of the hole, with the installation of the advantage screw at various angles. This study aims to compared the difference between the two types of interface screw - plate but also perform four-point test comparing the new locking system with the conventional system lock. Pullout tests conducted with conventional locking system (Synthes) and the new locking system (PAX) by screws 2.0mm; 2.4mm; 2.7mm and 3.5mm. In all groups tested the conventional system of blockade was stronger and showed a statistically significant difference, Mann-Witney test (p <0.05). P values were obtained: System 2.0mm P = 0.008; system 2.4 mm p = 0.008; System 2.7 mm p = 0.016; system 3.5 mm p = 0.008. In test points 4 used 20 Synthes plate mark (conventional blocking system) and 20 brand PAX (new locking system), the conventional locking system again showed a significant difference resistant. P values were obtained: System 2.0mm P = 0.008; system 2.4 mm p = 0.008; system 2.7 mm p = 0.008; system 3.5 mm p = 0.008. It follows that the conventional locking system has proved much more resistant peel test as in the four point bending test.
|
89 |
Protocolo de captação, processamento e transplante de enxertos osteocondrais homólogos a fresco na articulação do joelho / Protocol of procurement, processing and transplantation of fresh osteochondral allografts in the knee jointTirico, Luís Eduardo Passarelli 07 April 2015 (has links)
O tratamento das lesões condrais e osteocondrais do joelho em pacientes jovens ainda permanece um desafio para os médicos ortopedistas. As técnicas de reparo destas lesões atualmente disponíveis no Brasil, como desbridamento, microfraturas e transplante osteocondral autólogo são insuficientes nos tratamentos das lesões condrais e osteocondrais maiores do que 4 cm2. O transplante osteocondral homólogo a fresco (TOF) na articulação do joelho vem sendo usado em outros países com excelentes resultados. Até o presente momento não existem relatos da utilização desta técnica no Brasil, fato que dificulta o tratamento de pacientes jovens ativos que necessitam de reparo biológico. Foram incluídos neste estudo oito pacientes de 15 a 45 anos portadores de lesões osteocondrais maiores que 4 cm2. Os enxertos a fresco foram obtidos de doadores de órgãos, sendo a articulação do joelho captada sem violação da cápsula articular e transportada ao Banco de Tecidos para processamento. O pareamento doador e receptor foi realizado conforme o tamanho, a localização e a prioridade em lista de espera de acordo com os tecidos captados, sendo os mesmos armazenados no meio de preservação Ham F-12 - GIBCO com glutamax (Invitrogen, Life Technologies, Estados Unidos) e com antibióticos. O procedimento cirúrgico foi realizado pelas técnicas de cilindro osteocondral e de superfície, sendo fixados quando necessário. Os pacientes foram avaliados através dos questionários de IKDC objetivo, IKDC subjetivo, KOOS e índice de Merle D\'Aubigne e Postel modificado. Foram realizados oito TOFs de março a outubro de 2012. A média de idade dos pacientes transplantados foi de 30,1 anos (17- 44 anos) e a média da área transplantada foi de 10,6 cm2 (4,6 - 22,4 cm2). O intervalo médio em dias entre captação e transplante foi de 15,3 (14 - 16 dias) e o número médio de cirurgias prévias ao TOF foi de 2 cirurgias (0-4 cirurgias). A pontuação na escala de IKDC objetiva no pré-operatório foi B em 12%, C em 25% e D em 63% dos pacientes; e 12% A e 88% B aos 18 meses de pós-operatório. A média da pontuação da escala IKDC subjetiva pré-operatória foi de 31,99 ± 13,4 e de 81,84 ± 9,25 em 18 meses de pós-operatório, e da escala KOOS pré-operatória foi de 46,8 ± 20,9 e de 89,58 ± 7,06 em 18 meses de pós-operatório, com melhora significativa ao longo do tempo (p < 0,01) pela análise da variância. A média da pontuação pelo índice de Merle D\'Aubigne e Postel modificado foi de 8,75 ± 2,25 no pré-operatório e de 16,75 ± 2,19 em 18 meses de pós-operatório. O resultado do teste de Friedman para amostras não-paramétricas demonstrou melhora significativa ao longo do tempo (p < 0,01). A padronização da captação, processamento e transplante de enxertos osteocondrais a fresco na articulação do joelho depende de um banco de tecidos altamente especializado e leva a excelentes resultados no tratamento de lesões osteocondrais grandes, sendo atualmente uma boa alternativa de tratamento biológico para pacientes jovens no Brasil / Treatment of chondral and osteochondral lesions of the knee in young patients is still a challenge for Orthopedic Surgeons. The techniques available nowadays in Brazil, as debridement, microfracture and autologous osteochondral transplantation are insufficient for the treatment of chondral and osteochondral lesions larger than 4 cm2. Fresh osteochondral allografts on the knee joint have been used in other countries with great success. Until the present days there are no reports of the utilization of this technique in Brazil, a fact that creates boundaries for the treatment of young active patients that need cartilage repair treatment. Eight patients with age ranging from 15 to 45 years old and osteochondral lesions larger than 4 cm2 were included in this study. Fresh grafts were obtained from organ donors and the knee joint was harvest without violation of synovium capsule and then was transported to the tissue bank for processing. Donor and receptor tissue matching occurred according to size, localization and priority on waiting list and tissue was preserved in Ham F-12 - GIBCO media with glutamax (Invitrogen, Life Technologies, United States) and antibiotics. Surgical procedure was achieved with osteochondral plugs or shell techniques, with additional fixation when needed. Patients were evaluated with IKDC objective, IKDC subjective, KOOS and modified Merle D\'Aubigne-Postel outcome scores. Eight fresh osteochondral allografts were performed from march to october, 2012. The average age was 30.1 years old (17-44) and mean graft surface area was 10.6 cm2 (4.6 - 22.4 cm2). Average time from harvest to transplantation was 15.3 days (14-16 days) and mean number of previous surgical procedures was 2 (0 - 4 procedures). Pre-operative objective IKDC score was B in 12%, C in 25% and D in 63% and was A in 12% and B in 88% in 18 months follow-up. Pre-operative IKDC subjective and KOOS score were 31.99 ± 13.4 and 46.8 ± 20.9; and in 18 months follow-up were 81.84 ± 9.25 and 89.58 ± 7.06, respectively, with a significant increase along time on variance analysis (p < 0.01). Pre-operative mean modified Merle D\'Aubigne-Postel scores were 8.75 ± 2.25 and 16.75 ± 2.19 in 18 months follow-up. Non-parametric Friedman test analysis showed a significant progression in follow-up (p < 0.01). Standards of procurement, processing and utilization of fresh osteochondral allografts in the knee joint relay on a high specialized tissue bank and promote excellent results on the treatment of large osteochondral lesions, being a good alternative of a biologic repair for young patients in Brazil
|
90 |
Avaliação da interação biológica entre polímero de poliuretana de mamona acrescido de carbonato de cálcio e tecido ósseo de equinos / Biocompatibility of castor oil-calcium carbonate polymer with the equine bone tissueNóbrega, Fernanda Silveira 06 June 2014 (has links)
A reconstrução anatômica de fraturas em ossos longos em equinos é um grande desafio para o Médico Veterinário. Na tentativa de melhorar os resultados da técnica, estabilizando e preenchendo áreas onde houve perda óssea, o uso de substitutos ósseos, entre eles os biomateriais, vêm apresentando bons resultados. Os polímeros podem ser uma opção viável, funcional e economicamente, de substituto ósseo para aplicação em ortopedia de equinos. O objetivo deste estudo foi avaliar o comportamento biológico do equino frente à implantação de polímero de poliuretana de mamona acrescido de carbonato de cálcio após implante em osso III metacarpiano. Seis equinos hígidos foram submetidos à ostectomias unicorticais de 13mm de diâmetro na região proximal da superfície dorsal do III metacarpiano. Em seguida, de forma randômica, foi implantado o polímero de mamona em um membro torácico. No membro contralateral, foi reproduzida a técnica, porém a falha foi mantida sem preenchimento, servindo como controle do remodelamento ósseo. Todos os animais foram submetidos à avaliação física, radiográfica, ultrassonográfica, termográfica e perfil bioquímico previamente a cirurgia para identificação dos parâmetros pré-cirúrgicos. No período pós-operatório, os animais foram avaliados através de exame físico diário durante os 120 dias de observação, exame radiográfico, exame ultrassonográfico, exame termográfico e monitoramento do perfil sérico da fosfatase alcalina, cálcio e fósforo nos momentos sete, 15, 30, 60, 90 e 120 dias de pós-operatório. Com 120 dias de pós-operatório, novamente sob anestesia geral, realizou-se biópsia óssea com trefina de 0,5cm de diâmetro na área de interface implante-osso (membro polímero) e osso-osso neoformado (membro controle). O material foi processado e desmineralizado para microscopia de luz sendo realizadas técnicas de coloração de Hematoxilina-Eosina e Tricrômico de Masson para análise descritiva e morfométrica. A avaliação física de cada animal demonstrou não haver desconforto relacionado ao procedimento e à presença do implante, baseando-se na análise de presença de claudicação e parâmetros físicos (frequência cardíaca, frequência respiratória e temperatura retal) ao longo dos 120 dias. A avaliação ultrassonográfica permitiu identificação da formação de tecido mineralizado e pico de neovascularização no 30º dia de pós-operatório. A partir da dosagem sérica de fosfatase alcalina foi possível identificar pico desta enzima também no trigésimo dia. A avaliação termográfica demonstrou não haver aumento de temperatura local, decorrente de resposta inflamatória, ao longo do tempo de observação, porém foi possível identificar resposta mais intensa no 7º dia no membro polímero, quando comparado ao membro controle. O estudo histológico demonstrou comportamento osteocondutor do polímero sem reação de cápsula fibrosa ou resposta inflamatória crônica. Esta pesquisa apresentou resultados que demonstram biocompatibilidade do polímero de poliuretana de mamona acrescido de carbonato de cálcio em tecido ósseo equino e conclui-se que este biomaterial apresenta potencial para uso como substituto ósseo em equinos. / Anatomical reconstruction of long bone fractures remains a challenge to the equine practitioner to date. Bone surrogate biomaterials have been developed to improve surgical outcomes in cases involving bone tissue loss, with promising results. Biopolymers may be a feasible, functional and economically viable alternative for bone substitution in horses. This study evaluated the biological behaviour of castor oil-calcium carbonate polymer following implantation in the equine third metacarpal bone. Six healthy horses were submitted to bilateral dorsal unicortical osteotomy (13 mm in diameter) on the proximal aspect of the third metacarpal bone. One front limb was randomly selected for castor oil polymer implantation while the contralateral limb was left untreated to serve as control for bone remodeling. Preoperative evaluation consisted of physical, radiographic, ultrasonographic and thermographic assessment, and serum biochemistry profile determination. Horses were submitted to daily physical examination during the 120-day follow-up period. Radiographic, ultrasonographic and thermographic reassessments were performed on postoperative days seven, 15, 30, 60, 90 and 120, along with determination of alkaline phosphatase, calcium and phosphorus serum levels. On postoperative day 120, horses were reoperated under general anesthesia and a 0.5 mm biopsy fragment collected from the bone-implant or bone-new bone interface. Biopsy specimens were processed, demineralized, stained with hematoxylin-eosin or Massons trichrome and submitted to descriptive and morphometric analysis under light microscopy. Horses showed no signs of pain (i.e. lameness or changes in rectal temperature, heart and respiratory rates) related to the surgical procedure or the presence of the implant during the 120-day follow-up period. Ultrasonographic reassessment revealed mineralized tissue formation and peak neovascularization on postoperative day 30. Peak alkaline phosphatase levels were also observed on the same day. Local temperature differed significantly between treated and control limbs on postoperative day 7, but not thereafter. Absence of encapsulation or signs of chronic inflammatory response on histology suggests osteoconductive behaviour of the Ricinus communis polymer. Based on the results of this study, castor oil-calcium carbonate polymer is biocompatible with the equine bone tissue and represents a potential surrogate biomaterial for bone substitution in horses.
|
Page generated in 0.0444 seconds