• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 984
  • 34
  • 34
  • 34
  • 34
  • 29
  • 29
  • 18
  • 14
  • 14
  • 6
  • 4
  • 1
  • 1
  • Tagged with
  • 1004
  • 450
  • 288
  • 190
  • 188
  • 167
  • 158
  • 156
  • 150
  • 145
  • 127
  • 111
  • 106
  • 94
  • 93
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
341

Comparação da razão carga-deflexão do fio flexy-multi® com fios de aço, beta-titânio e níquel-titânio de diversas marcas comerciais / Comparison of the load-deflection rate of niti/beta-titanium with stainless-steel, beta-titanium and nickel-titanium wires from different manufacturers

Póvoa, Vinícius Marcelo Aires 21 December 2011 (has links)
Submitted by Erika Demachki (erikademachki@gmail.com) on 2016-08-29T18:10:51Z No. of bitstreams: 2 Dissertação - Vinícius Marcelo Aires Póvoa - 2011.pdf: 2752370 bytes, checksum: 9fbffc261c22bdc57a1b99d2aed34d3e (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Approved for entry into archive by Erika Demachki (erikademachki@gmail.com) on 2016-08-29T18:12:36Z (GMT) No. of bitstreams: 2 Dissertação - Vinícius Marcelo Aires Póvoa - 2011.pdf: 2752370 bytes, checksum: 9fbffc261c22bdc57a1b99d2aed34d3e (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2016-08-29T18:12:36Z (GMT). No. of bitstreams: 2 Dissertação - Vinícius Marcelo Aires Póvoa - 2011.pdf: 2752370 bytes, checksum: 9fbffc261c22bdc57a1b99d2aed34d3e (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2011-12-21 / Flexy-Multi™, a newly introduced finishing wire with the outermost portion of its crosssection composed by nickel-titanium and its core by beta-titanium, was evaluated according to its flexural behavior in bending tests. The aim of this study was to compare the loaddeflection rate of Flexy-Multi™ to stainless-steel, beta titanium and nickel-titanium archwires in three-point bending test. The samples examined included 0.017”x 0.025”-inch stainlesssteel, beta-titanium, nickel-titanium and Flexy-Multi™ wires. Each combination, alloy and manufacturer, was tested 6 times and an average was obtained for comparison. All specimens were tested in a universal testing machine (EMIC DL10.000/700) in a 3-point bending test at a speed of 1mm per minute and deflected for 1.5 mm. Loading and unloading forces were recorded at each 0.5mm of deflection and load-deflection curves were determined. Three self-ligating brackets of lower incisors (In-Ovation – GAC Orthodontics, Roth prescription, slot .022”x.028”) were used as supports to the wires. On loading, there was no difference between Flexy-Multi™ and all nickel-titanium wires tested. On the other hand, Flexy-Multi™ showed lower load-deflection rates than all stainless-steel and betatitanium wires both on loading and unloading (p>0.05). On unloading, Flexy-Multi™ showed lower load-deflection rate than all nickel-titanium wires just to 0.5mm of deflection (p<0.05). Flexy-multi™ presented a lower load-deflection rate than all wires tested, except when compared to nickel-titanium where this difference came up just at the level of 0.5mm of unloading, since this wire lost force by the end of the test. / O Flexy-Multi®, fio recentemente introduzido ao mercado brasileiro, composto por uma camada externa de níquel-titânio e um núcleo central de beta-titânio, foi avaliado de acordo com o seu comportamento mecânico em testes de flexão. O objetivo do presente trabalho foi comparar a proporção carga/deflexão do Flexy-Multi® com fios de aço, beta-titânio e níquel-titânio em testes de flexão em três bráquetes. As amostras avaliadas constituíam-se de fios 0,017” x 0,025” de aço, beta-titânio, níquel-titânio e o Flexy-Multi®. Cada combinação, liga e fabricante, foi testada 6 vezes e médias foram obtidas para comparação. Todos os espécimes foram submetidos a ensaios de flexão em três pontos em máquina universal de ensaio EMIC DL10.000/700, utilizando bráquetes autoligados de incisivos inferiores (In-Ovation, slot 0,022” x 0,028” e prescrição Roth) como suportes. A velocidade dos ensaios foi de 1mm/min com deflexão máxima de 1,5mm. Forças de ativação e desativação foram registradas a cada 0,5mm e curvas carga x deflexão estabelecidas. Na ativação, não houve diferença entre o Flexy-Multi® e os demais fios de níquel-titânio testados. Por outro lado, o Flexy-Multi® mostrou menor proporção carga/deflexão que todos os fios de aço e beta-titânio, tanto na ativação quanto na desativação (p>0,05). Na desativação, o Flexy-Multi® mostrou menor proporção carga-deflexão que todos os fios de níquel-titânio testados apenas para 0,5mm de deflexão (p<0,05). O Flexy-Multi® apresentou menor proporção carga-deflexão que todos fios testados, exceto quando comparado aos fios de níquel-titânio, já que neste caso esta diferença se evidenciou apenas para 0,5mm de deflexão na desativação, evidenciando uma perda de força deste fio ao final do teste.
342

Desenvolvimento de um dispositivo posicionador de acessórios ortodônticos com precisão vertical

Mota Júnior, Sergio Luiz 29 March 2016 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2016-07-26T14:40:46Z No. of bitstreams: 1 sergioluizmotajunior.pdf: 31675383 bytes, checksum: 4a7f6f6e29158d411892c2d4acac4c92 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2016-07-27T11:29:40Z (GMT) No. of bitstreams: 1 sergioluizmotajunior.pdf: 31675383 bytes, checksum: 4a7f6f6e29158d411892c2d4acac4c92 (MD5) / Made available in DSpace on 2016-07-27T11:29:40Z (GMT). No. of bitstreams: 1 sergioluizmotajunior.pdf: 31675383 bytes, checksum: 4a7f6f6e29158d411892c2d4acac4c92 (MD5) Previous issue date: 2016-03-29 / FAPEMIG - Fundação de Amparo à Pesquisa do Estado de Minas Gerais / O correto posicionamento dos bráquetes é importante para garantir o alinhamento e nivelamento dos dentes durante o tratamento ortodôntico. Há instrumentos posicionadores que são utilizados para determinar a posição vertical adequada dos acessórios na superfície dentária. Mesmo estes instrumentos são passíveis de erros durante sua utilização, por permitirem a inclinação vestíbulo-lingual, levando os bráquetes a uma posição inadequada. Prejudicam todo o tratamento, e causam problemas dentários individuais como: alteração do comprimento do arco dentário; provocam intrusões, extrusões, contatos pré-maturos e; consequentemente comprometem todo o sistema mastigatório. Baseado nesta limitação dos instrumentos posicionadores verticais atualmente disponíveis no mercado, o objetivo deste estudo foi descrever o desenvolvimento, apresentar e testar um posicionador do tipo estrela que impeça a inclinação vestíbulo-lingual durante o seu uso. O instrumento foi criado, modelado, patenteado e prototipado para os testes laboratoriais. Para os testes, foram formados quatro grupos com diferentes tempos de experiência clínica em Ortodontia, composto por seis participantes em cada grupo. Cada indivíduo colou bráquetes edgewise 0,022”x0,028” em um manequim typodont com maloclusão Classe I em incisivos, caninos e pré-molares superiores e inferiores. Eles utilizaram primeiramente a estrela de Boone e posteriormente a Estrela UFJF (houve pelo menos 30 dias de diferença entre as colagens). Os estudos mostraram que o uso da Estrela UFJF propiciou médias de colagem mais próximas à considerada ideal no presente estudo (4mm) nos grupos que apresentavam alguma experiência em Ortodontia. Nos grupos de dentes avaliados, o desvio padrão em relação 4mm foi menor quando utilizada a Estrela UFJF se comparado ao uso da estrela de Boone. Todos experimentos apresentaram menores variâncias quando utilizada a Estrela UFJF. Conclui-se, desta forma, que o instrumento desenvolvido apresentou menores variações no posicionamento vertical dos bráquetes ortodônticos quando associado à experiência clínica, sendo esta necessária para seu uso. / The bracket placement is important for the appropriate teeth alignment and leveling during orthodontic treatment. Instruments can be used to determine the position of vertical attachments at dental surface. They are prone to fail during their use because they allow buccolingual inclination and take wrong position of attachments. It may jeopardize a treatment, causing to individuals severe dental problems, such as change the length of the dental arch, intrusions, extrusions, premature contacts and even commit all estomatognatic system. Based on the vertical limitation of some instruments positioners, the aim of this study was to develop and test a star-like positioner that prevents a buccolingual inclination during its use. The instrument was created, modeled, patented and prototyped for laboratory tests. For analysis, 4 groups were defined with different clinical experience in orthodontics, with 6 participants in each group. Each individual bonded edgewise 0.022x0,028in brackets in a typodont with Class I malocclusion in maxillary and mandibular incisors, canines and premolars, first with a Boone gauge and at least 30-days after, with Estrela UFJF. Studies showed that Estrela UFJF had averages closer to the ideal (4mm) in groups with some experience in orthodontics than Boone gauge. In all groups available, the standard deviation was lower with the Estrela UFJF than with Boone gauge. Specific groups of teeth, which variances were lower with Estrela UFJF than with Boone gauge. It is concluded that the developed instrument presented less variations in bracket vertical positioning and some clinical orthodontic experience is necessary to its use.
343

AVALIAÇÃO COMPARATIVA ENTRE AGRADABILIDADE FACIAL, PROPORÇÃO ÁUREA E PADRÃO FACIAL

Morihisa, Olivia 30 March 2006 (has links)
Made available in DSpace on 2016-08-03T16:31:06Z (GMT). No. of bitstreams: 1 Dissertacao Olivia Morihisa.pdf: 1468336 bytes, checksum: 2be8ff54a9d3afe65cb3dc995e2fba72 (MD5) Previous issue date: 2006-03-30 / The purpose of this research was to study some facial analysis used in orthodontic diagnosis and to verify the agreement between lateral and frontal views in the evaluation of the face attractiveness done by lay and professional groups, the agreement between these groups in the evaluation of the face attractiveness on both lateral and frontal views, as well as to verify the association between face attractiveness and Facial Golden Proportion, face attractiveness and Facial Pattern and between Facial Pattern and Facial Golden Proportion. Two hundred and eight standardized facial photographs (104 in lateral view and 104 in frontal view) of a hundred and four randomly chosen individuals were used. The pictures were first classified in pleasant , acceptable and not pleasant by the Orthodontics and Layman groups. Then Facial Golden Proportion measurements were made in lateral and frontal views by means of a computerized program and the individuals were classified on their Facial Pattern by its lateral aspect. After statistical analysis, it was noted that there was no agreement between groups and views in the facial attractiveness classification, as well as in the association between Golden Proportion measurements and facial attractiveness or Facial Pattern. Considering Facial Pattern and attractiveness, there was strong association in the lateral view, however in the frontal view there was no association, for both observers groups. Key words: Orthodontics; diagnosis; Facial analysis; photograph; Golden Proportion. / O propósito desta pesquisa foi estudar algumas análises faciais utilizadas para diagnóstico ortodôntico e verificar a concordância entre norma lateral e frontal na avaliação da agradabilidade facial para os grupos leigos e profissionais, a concordância entre estes grupos na avaliação da agradabilidade facial nas normas lateral e frontal, bem como verificar a associação entre agradabilidade facial e Proporção Áurea, agradabilidade facial e Padrão Facial e entre Padrão Facial e Proporção Áurea. Utilizou-se 208 fotografias faciais padronizadas (104 laterais e 104 frontais) de 104 indivíduos escolhidos aleatoriamente, que primeiramente foram classificadas em agradável , aceitável e desagradável por dois grupos distintos: grupo Ortodontia e grupo Leigos . As fotografias laterais e frontais foram submetidas a medidas de Proporção Áurea Facial por meio de programa computadorizado e os indivíduos foram classificados quanto ao Padrão Facial pelo seu aspecto lateral. Após análise estatística, verificou-se que não houve concordância entre as variáveis da avaliação de agradabilidade estudadas, bem como não houve associação entre Proporção Áurea com agradabilidade facial ou com Padrão Facial. Entre agradabilidade facial e Padrão Facial, observou-se para a norma lateral associação fortemente positiva, porém para a frontal não houve associação para ambos os grupos de avaliadores.
344

Análise periodontal em pacientes submetidos à tratamento ortodôntico corretivo: avaliação clínica, microbiológica e imunológica / Periodontal analysis in patients submitted to orthodontic treatment: clinical, microbiological and immunological evaluation

Shirozaki, Mariana Umekita 29 August 2018 (has links)
O biofilme é um dos fatores primários para o desenvolvimento da gengivite, periodontite e outras alterações na saúde gengival do paciente. O tratamento ortodôntico é um fator predisponente para adesão de microrganismos deixando o paciente susceptível ao maior acúmulo de biofilme e, consequentemente, às doenças periodontais. Assim, o objetivo do presente estudo foi avaliar as alterações clínicas, microbiológicas e imunológicas no paciente em tratamento ortodôntico corretivo e testar as hipóteses nulas: 1 - não há diferença nos parâmetros clínicos, microbiológicos e imunológicos antes e durante o tratamento ortodôntico, 2 não há correlação entre os índices clínicos e imunológicos. Em 28 pacientes com necessidade de tratamento ortodôntico corretivo foram avaliados parâmetros clínicos como índice de Placa (IP), índice de Sangramento (IS), largura de gengiva queratinizada (LGQ); parâmetros microbiológicos por meio da contagem de 40 espécies subgengivais em amostras de biofilme (Checkerboard DNA-DNA Hybridization) e avaliação imunológica por meio da expressão dos níveis de Interleucina-1 &beta; (IL-1&beta; ), metaloproteínase da matriz-8 (MMP-8) e Fator de Necrose Tumoral (TNF-&alpha;) no Fluído Crevicular Gengival (FCG) (Luminex). Foram realizadas coletas em 3 momentos: T0 = antes da colocação do aparelho; T1 = 6 meses após e T2= 12 meses após o início do tratamento. Para as análises clínicas e microbiológicas foram aplicados teste de Friedman e Wilcoxon com correção de Bonferroni e para a análise imunológica, Análise de variância para medidas repetidas. Não foi observada diferença estatisticamente significante para a LGQ. IP apresentou aumento, sendo estatisticamente significante em T1 (70,58±28,56) e T2 (83,23±12,30) quando comparados ao T0 (24,44±11,56). O IS apresentou aumento estatisticamente significante em T1 (7,97±5,04) e diminuição em T2 (6,20±4,09), demonstrando valores sem diferença estatisticamente significante a T0 (4,54±4,98). Na análise microbiológica, dentre os seis complexos analisados, apenas o complexo vermelho apresentou frequência significativamente maior (p=0,001) em T2. Não houve diferença estatisticamente significante nos valores dos níveis das citocinas avaliadas, entre todos os tempos (p>0,05), porém em T2 houve correlação positiva moderada entre IS e IL-1&beta; (r=0,49 p=0,01) e TNF-&alpha; (r=0,39 e p=0,05). As hipóteses nulas foram rejeitadas. O tratamento ortodôntico corretivo causou alterações periodontais clínicas com relação ao acúmulo de biofilme e sangramento gengival, alterações de bactérias periodontopatogênicas, além de gengivite após 6 meses de tratamento / The biofilm is one of the primary factors for the gingivitis and periodontitis development and changes in periodontal health. Orthodontic treatment is a predisposing factor for microorganisms adhesion leaving the patient susceptible to greater biofilm accumulation and, consequently, to periodontal diseases. Therefore, the study aimed to analyze clinical, microbiological and immunological parameters in patients in orthodontic treatment. The null hypothesis tested were: 1 - there is no difference in clinical, microbiologica and immunological parameters before and during orthodontic treatment; 2 there is no correlation between clinical and immunological parameters. In twenty-eight patients with corrective orthodontic treatment were evaluated clinical parameters, such as Plaque index (PI), Bleeding on Probing (BOP) and width of keratinized gingiva; microbiological parameters with counting of 40 subgingival species with Checkerboard DNA-DNA hybridization and immunological evaluation of cytokines levels IL-1&beta; , MMP-8 and Tumor Necrosis Factor (TNF-&alpha;) in Gingival Crevicular Fluid (GCF). Samples were collected in three times: T0 = before orthodontic treatment; T1 = 6 months after and T2 = 12 months after starting orthodontic treatment. Data from clinical and microbiological evaluation were statistically analyzed with Friedman and Wilcoxon tests with Bonferroni correction and for the immunological analysis, Analysis of variance for repeated measures were applied. No significant difference was found for the width of keratinized gingiva. PI presented an increase, being statistically significant at T1 (70.58±28.56) and T2 (83.23±12.30) when compared with T0 (24.44±11.56). The BOP showed a statistically significant increase at T1 (7.97±5.04), however, at T2 (6.20±4.09) the values decrease with no statistically significant difference with T0 (4.54±4.98). In the microbiological analysis, the red complex showed significantly greater frequency (p=0.01) at T2. There was no statistically significant difference in the cytokine levels between the times, but there was a positive moderate correlation between BOP and IL-1&beta; (r=0.49 p=0.01) and TNF-&alpha; (r=0.39 e p=0.05). The null hypothesis were rejected. Corrective orthodontic treatment caused clinical periodontal changes regarding biofilm accumulation and gingival bleeding, alterations of periodontopathogens, besides gingivitis after 6 months of treatment
345

Estudo cefalométrico comparativo das alterações decorrentes do uso de dois tipos de aparelhos extrabucais em jovens com má oclusão de Classe II, 1ª divisão de Angle / Comparative cephalometric study of alterations in the Angle Class II division 1 malocclusion in young individuals treated with two types of headgear

Henriques, Rafael Pinelli 17 January 2005 (has links)
O presente trabalho propôs avaliar cefalometricamente as alterações dentárias, esqueléticas e tegumentares em jovens com má oclusão de Classe II, 1ª divisão tratados com o aparelho extrabucal conjugado (splint maxilar) e com o aparelho extrabucal de tração occipital (IHG). Os grupos experimentais foram comparados à um grupo controle, que apresentavam a mesma má oclusão, pareados pelo gênero, idade e tempo de observação. Um total de 150 telerradiografias em norma lateral de 75 jovens fizeram parte da amostra, divididos em três grupos de 25. Os jovens do grupo 1 foram tratados com o aparelho extrabucal conjugado, apresentaram uma idade média inicial de 9,71 anos e foram observados pelo período médio de 1,41 anos. O grupo 2, foi submetido ao tratamento utilizando o aparelho extrabucal de tração occipital (IHG), com idade média inicial de 10,51 anos e acompanhados por um período de 1,32 anos. Os jovens do grupo 3 foram mantidos como controle, apresentaram uma idade média inicial de 10,06 anos e foram observados pelo período médio de 1,35 anos. Todas as mensurações foram submetidas à análise estatística. A análise dos resultados mostrou que o deslocamento anterior da maxila foi restringido significantemente nos grupos experimentais. A mandíbula apresentou um aumento de seu crescimento efetivo (Co-Gn) estatisticamente significante no grupo tratado com o aparelho AEB conjugado. A relação maxilomandibular melhorou significantemente nos grupos tratados. Em relação às alterações dentoalveolares superiores, o grupo tratado com o aparelho AEB conjugado apresentou uma inclinação para lingual dos incisivos superiores enquanto os outros 2 grupos apresentaram uma discreta inclinação para vestibular destes dentes. A movimentação de distalização dos molares superiores foi significante para os grupos experimentais. A movimentação de extrusão dos molares inferiores mostrou também um resultado não significante entre os grupos. Com relação ao perfil tegumentar, constatou-se que o ângulo nasolabial não apresentou modificação pelo tratamento, assim como a posição espacial do lábio inferior. Já o lábio superior demonstrou uma maior retrusão nos grupos experimentais com diferença estatística significante. Desta maneira, verificou-se que ambos protocolos de tratamento propiciaram alterações esqueléticas, dentárias e tegumentares clinicamente relevantes para a correção da má oclusão de Classe II, 1ª divisão. / This study conducted a cephalometric evaluation of the dental, skeletal and soft tissue alterations in young individuals with Class II division 1 malocclusion treated with the maxillary splint and high-pull headgear (HPH). The study groups were compared to a control group presenting the same malocclusion matched for gender, age and period of observation. A total of 150 lateral cephalograms of 75 young individuals were analyzed, which were divided into three groups with 25 individuals each. The individuals in group 1 were treated with the maxillary splint, presented an initial mean age of 10 years and were observed for 1 year and 4 months. Group 2 was treated with the highpull headgear (HPH), had an initial mean age of 10 years and was followed for 1 year and 4 months. The subjects in group 3 were kept as controls, presented an initial mean age of 10 years and were observed for a mean period of 1 year and 4 months. All measurements were submitted to statistical analysis. The results demonstrated that interception of the Class II division 1 malocclusion in the study groups was significant, presenting specific effects inherent to each appliance investigated. The anterior maxillary displacement was significantly restricted in the study groups compared to the control group, especially for the group treated with HPH. The mandible presented a statistically significant increase in effective growth (Co_Gn) in the group treated with the maxillary splint, yet its anterior displacement (SNB) did not present significant alterations. The maxillomandibular relationship was significantly improved in the study groups. The vertical components did not present statistically significant differences between groups. With regard to the dentoalveolar alterations in the maxillary arch, the group treated with the maxillary splint presented a significant restriction in buccal inclination of the maxillary incisors. Distal movement of the maxillary molars was significant for both study groups, being larger for the group treated with the HPH, especially as to the crown movement (FHP_DISTAL6). Extrusion of the mandibular incisors was more restricted (1_GoMe) in the group treated with the maxillary splint, followed by the group treated with the HPH, yet with non-statistically significant outcomes. Extrusion of the mandibular molars was also non-significant between groups. With regard to the soft tissue profile, the nasolabial angle was not changed by treatment, as well as the position of the lower lip. On the other hand, the upper lip presented more retrusion in the group treated with the maxillary splint, followed by the group treated with the HPH, with statistically significant difference between the study groups and the control group. Therefore, it was concluded that both treatment protocols provided clinically relevant skeletal, dental and soft tissue alterations for correction of the Class II division 1 malocclusion.
346

Avaliação da resistência à flexão de mini-implantes desenvolvidos para ancoragem esquelética do aparelho de Herbst - Estudo em Minipig br1 / Flexure resistance evaluation of mini implants prototypes developed for Herbst appliance anchorage Study in Minipig br1

Batista, Klaus Barretto dos Santos Lopes 23 April 2010 (has links)
Um efeito colateral indesejável do uso do aparelho de Herbst é a vestibularização excessiva dos incisivos inferiores que pode estar relacionada à retração gengival, à perda óssea marginal e à reabsorção radicular. A ancoragem esquelética do aparelho de Herbst poderia evitar estes problemas. O objetivo do presente estudo foi o de avaliar, em Minipigs br1, a resistência à flexão de protótipos de mini-implantes desenvolvidos para ancoragem do aparelho de Herbst, comparar a resistência dos protótipos entre as duas regiões escolhidas para inserção e avaliar se os protótipos de mini-implantes seriam capazes de suportar forças ortopédicas. Após o cálculo do tamanho da amostra, 13 protótipos de mini-implantes foram colocados nas regiões posterior da maxila e anterior da mandíbula de três Minipigs br1, após terem sido mortos. Corpos de prova contendo os protótipos de mini-implantes inseridos em osso foram submetidos a uma força de flexão por engastamento simples utilizandose uma máquina universal de ensaios mecânicos Instron, calculando-se a média e o desvio padrão para cada região. Com o objetivo de comparar a resistência dos protótipos entre as regiões de inserção foi utilizado o Teste t de Student para duas amostras não pareadas. O teste de hipótese foi realizado para cada região para avaliar se os protótipos de mini-implantes seriam capazes de suportar forças ortopédicas. Para fins de comparação foram consideradas forças ortopédicas acima de 1,0 kgf. O nível de significância adotado foi P < 0,05. Os protótipos de miniimplantes apresentaram resistência à força de flexão de 13,86 kgf (DP = 2,3) para a região posterior da maxila e 20,55 kgf (DP = 5,2) para a região anterior da mandíbula. Houve diferença estatisticamente significativa entre as duas regiões com relação à força de resistência dos mini-implantes (P = 0,015), sendo que a resistência maior foi na região anterior da mandíbula. A hipótese de que os protótipos de mini-implantes seriam capazes de suportar forças ortopédicas foi confirmada para as regiões posterior da maxila e anterior da mandíbula. Os autores concluíram que, em Minipigs br1, os protótipos de mini-implantes desenvolvidos para a ancoragem do aparelho de Herbst foram capazes de resistir a forças entre 13,86 e 20,55 kgf, sendo estatisticamente mais resistentes na região anterior da mandíbula e capazes de suportar forças ortopédicas. / An undesirable tooth movement resulting from use of the Herbst appliance is the excessive proclination of the anterior mandibular teeth, which is commonly associated with gingival recession, marginal bone loss, and root resorption. Skeletal anchorage of the Herbst appliance could prevent these problems. The present study was designed to evaluate, in Minipigs br1, the flexure resistance of prototype miniimplants developed for Herbst appliance anchorage, to compare the prototype resistance between the regions in which the mini-implants were placed, and to test the hypothesis that these mini-implant prototypes can withstand orthopedic forces. After calculation of sample size, 13 mini-implant prototypes (2 mm in diameter x 10 mm long) were inserted in the posterior region of the maxilla and the anterior region of the mandible, in three recently killed minipigs. The specimens were submitted to a single cantilever flexure test using an Instron testing machine. Mean and standard deviation were calculated for each region. To compare the resistance of the prototypes between the sites of mini-implant insertion, a 2-Sample Students t test was calculated. The test was carried out individually for each region, to evaluate if the prototype mini-implants developed for Herbst appliance anchorage could withstand orthopedic forces. Orthopedic forces above 1.0 kgf were considered. The level of significance was set at P < 0.05. The prototype mini-implant showed a flexure strength of 13.86 kgf (SD = 2.3) for the posterior region of the maxilla, and 20.55 kgf (SD = 5.2) for the anterior region of the mandible. A significant statistically difference was found in the resistance of the prototypes between the two regions (P = 0.015). The hypothesis that the prototype mini-implants can withstand orthopedic forces was confirmed. The authors concluded that, in Minipigs br1, the prototype mini-implants developed for Herbst appliance anchorage could resist forces from 13.86 to 20.55 kgf, were statistically more resistant in the anterior region of the mandible, and were capable of withstanding orthopedic forces.
347

Carga imediata sobre implantes osseointegráveis para ancoragem ortodôntica: estudo em minipigs / Immediately loaded osseointegrated implants for orthodontic anchorage: study in minipigs

Navarro, Paula Vanessa Pedron Oltramari 17 December 2008 (has links)
O objetivo deste trabalho foi avaliar a taxa de sucesso, a quantidade de perda óssea em altura e a interação osso/implante para três diferentes protocolos: 1) implantes osseointegráveis mantidos sem carga durante período de reparo de 120 dias; 2) implantes submetidos a interferências oclusais; e 3) implantes que receberam carga imediata para ancoragem ortodôntica. Foram utilizados doze minipigs BR-1, nos quais foram instalados 70 implantes osseointegráveis de titânio (3,75mm diâmetro x 8,50mm comprimento), divididos em 5 grupos: Grupo 1 (n=12), implantes sem carga sepultados na mesial de caninos; Grupo 2 (n=6), implantes sem carga em áreas de extração; Grupo 3 (n=12), implantes expostos a interferências oclusais; Grupo 4 (n=20), implantes submetidos à carga ortodôntica imediata; Grupo 5 (n=20), implantes instalados em áreas de extração e submetidos à carga ortodôntica imediata. Ao término do período experimental, os animais foram eutanasiados e biópsias da região de interesse coletadas. Realizou-se avaliação clínica para estabelecer a porcentagem de sucesso (Teste Exato de Fisher), análise radiográfica para quantificar a perda óssea em altura (programa de análise de imagens KS300-Zeiss®, ANOVA) e análise histológica para descrever as características da interface osso/implante. A análise dos dados demonstrou: 1) Grupos 1, 2, 4 e 5 - taxa de sucesso, quantidade de perda óssea em altura e interação osso/implante semelhantes; 2) Grupo 3 - taxa de insucesso e quantidade de perda óssea significantemente maiores que os demais grupos, além de apresentar ausência de interação osso/implante. Os resultados clínicos, radiográficos e histológicos revelados nos grupos submetidos à carga ortodôntica imediata em relação aos grupos sem carga demonstraram que a perda óssea na região da crista óssea periimplantar é aceitável e não compromete a estabilidade clínica dos implantes. Desta forma, a utilização de carga imediata para ancoragem em Ortodontia não prejudica a posterior utilização desses implantes para a reabilitação protética, objetivo primário da indicação deste protocolo. Estudos clínicos prospectivos são necessários para comprovar estes dados. / This research aimed at evaluating the success rate, the bone height loss, and the bone/implant interface in three different protocols: 1) osseointegrated implants maintained without load during a repair period of 120 days; 2) osseointegrated implants submitted to occlusal interferences; and 3) immediately loaded osseointegrated implants for orthodontic anchorage. Twelve BR-1 minipigs were used, in which 70 osseointegrated titanium implants were inserted (3.75mm diameter x 8.50mm length), divided into 5 groups: Group 1 (n=12), submerged implants without load; Group 2 (n=6), implants without load in extraction sites; Group 3 (n=12), implants exposed to occlusal interferences; Group 4 (n=20), exposed implants submitted to immediate orthodontic load; Group 5 (n=20), exposed implants inserted in extraction sites and submitted to immediate orthodontic load. At the end of the experimental period, the animals were euthanized and biopsies of the areas of interest were harvested. The clinical analysis (Exact Fisher Test) revealed the success rate of the inserted implants, the radiographic analysis quantified the bone height loss (image analysis program KS300-Zeiss®, ANOVA), and the histological analysis showed the bone/implant interface characteristics. The data analysis revealed: 1) Groups 1, 2, 4 and 5 - similar success rate, bone height loss and bone/implant interface characteristics; 2) Group 3 - statistically greater fail rate and bone height loss, and absence of bone/implant interaction characteristics. Clinical, radiographic and histological results presented in the groups submitted to immediate orthodontic load compared with the other without load demonstrated that the bone loss in the bone crest area is acceptable, and does not compromise the clinical stability of the implants. Therefore, the use of immediate load for orthodontic anchorage did not jeopardize the subsequent use of the implants for oral prosthetic rehabilitation, the main objective of this protocol. Further clinical studies are necessary to confirm these data.
348

Influência da base craniana sobre as dimensões transversais das bases apicais e dos arcos dentários / Influence of cranial base on transverse dimensions of apical bases and arches

Almeida, Carolina Pedrinha de 08 April 2011 (has links)
Esta pesquisa foi realizada para verificar se o padrão morfogenético da base craniana é determinante das dimensões transversais da maxila e mandíbula e se tal influência também se estende à porção alveolar das bases apicais. Complementarmente buscou-se avaliar as inclinações vestíbulo-linguais dos dentes posteriores com intuito de verificar se tais inclinações são padronizadas, independente das larguras das bases alveolares, ou se existem variações significativas. A amostra foi composta por 30 indivíduos adultos jovens, brasileiros, leucodermas com perfis faciais equilibrados e neutro-oclusão. Dividiu-se em dois grupos de acordo com a dimensão transversal da base anterior do crânio, definida pela distância entre os pontos esfenóide direito e esquerdo, sendo o grupo G1 composto pelos indivíduos apresentando valores menores que a mediana, e o grupo G2 com indivíduos apresentando valores maiores ou iguais a mediana. Foi realizada correlação intraclasse para avaliar o erro do método; média, mediana e desvio padrão para descrever o grupo amostral; teste t-Student para comparar os grupos G1 e G2; teste exato de Fischer para avaliar associação entre base do crânio e gêneros e Teste de Correlação Linear de Pearson. As medidas apresentaram alta reprodutibilidade. Indivíduos do grupo G2 apresentaram maior largura de mandíbula e maior espessura alveolar dos primeiros molares e primeiros pré-molares superiores. Não houve associação entre largura de base do crânio e gêneros. A largura basal da mandíbula apresentou correlação estatisticamente significante com a largura da base do crânio, assim como a largura alveolar maxilar na região de prémolares e molares superiores em relação à largura basal da maxila. As conclusões foram: a largura da base craniana apresenta correlação com a largura da mandíbula; a largura da maxila varia em consonância com a largura da mandíbula; a largura alveolar da maxila na região de primeiros pré-molares e molares superiores apresenta correlação com largura basal da maxila; a largura basal mandibular apresenta correlação com a largura alveolar da mandíbula na região dos primeiros pré-molares; as inclinações vestíbulo-linguais dos primeiros molares e primeiros prémolares são constantes, independentes das larguras basais e alveolares de suas respectivas bases ósseas. / This research intended to check if the morphogenetic pattern of cranial base determines transverse dimensions of upper and lower face and if it extends to alveolar portion basis. In addition evaluated buccal-lingual inclinations of posterior teeth to examine if they are standardized, regardless of the widths of the alveolar bases, or whether there are significant variations. The sample comprised 30 young adults, Caucasian Brazilian facial profiles with balanced and neutral occlusion. Divided into two groups according to the transverse dimension of the anterior skull base, defined by the distance between right and left sphenoid´s points, the G1 made of individuals with lower values than the median, and G2 with individuals with values greater or equal to median. Intraclass correlation was performed to evaluate the method error, mean, median and standard deviation to describe the sample group, Student t test to compare the groups G1 and G2, Fisher exact test to access the relation between skull base and genres and Test Linear correlation of Pearson. Measurements showed high reproducibility. G2 individuals showed greater mandible width and greater thickness of alveolar bone on upper first molars and first premolars. There was no association between width of skull base and genres. The width of the mandible showed a statistically significant correlation with the width of the skull base and maxillary alveolar width in premolars and molars in relation to basal width of jaw. Conclusions: the width of cranial base is correlated with width of jaw; jaw width varies in line with jaw width and width of maxillary alveolar region of first premolars and molars is correlated with basal width jaw, the basal mandibular width correlates with width of jaw in alveolar region first premolars; the buccolingual inclinations of the first molars and first premolars are constant, independent of basal width and alveolar bone of their respective bases.
349

Avaliação tridimensional da descompensação dentária e remodelação óssea pré-cirúrgica nas más oclusões de classe III / Tridimensional evaluation of presurgical orthodontic decompensation and bone remodeling in subjects with class III dentofacial deformity

Sendyk, Michelle 14 September 2018 (has links)
Esta pesquisa foi realizada com o objetivo de identificar as inclinações dentárias vestíbulo-linguais dos dentes inferiores e as características morfológicas da sínfise mandibular decorrentes do movimento de descompensação dentária. A amostra constituiu-se de 30 indivíduos adultos, com deformidade dentofacial de classe III, submetidos ao tratamento ortodôntico pré-cirúrgico. A partir de imagens tridimensionais geradas por exames de tomografia computadorizada de feixe cônico, em dois tempos distintos (inicial e previamente à realização da cirurgia ortognática) foram obtidos modelos virtuais tridimensionais, que foram sobrepostos por meio do registro pelo voxel na base do crânio e na mandíbula, para avaliação da direção e quantidade de rotação mandibular, deslocamento do mento, deslocamento do ponto B, movimento de descompensação dentária dos incisivos e molares inferiores e inclinação e espessura da sínfise mandibular. Os deslocamentos tridimensionais de pontos de referência na sínfise foram quantificados e visualizados por mapas codificados por cores e sobreposições semitransparentes por meio do programa SlicerCMF 3-1® versão 4.5.0. O teste de Correlação de Pearson foi utilizado para verificar a correlação entre inclinação dentária, espessura, inclinação da sínfise e deslocamento do ponto B. As espessuras e inclinações médias da sínfise foram comparadas entre os tempos inicial e pré-cirúrgico com uso de testes t-Student pareado. As medidas apresentaram alta reprodutibilidade. A maioria dos pacientes apresentou rotação horária da mandíbula e deslocamento do mento no sentido posterior e inferior. O ponto B se movimentou no sentido posterior e superior. Além disso, os incisivos inferiores apresentaram vestibularização, que foi condizente com o movimento de descompensação dentária originado pelo preparo pré-cirúrgico. Foram encontradas correlações estatisticamente significativas entre a inclinação dos incisivos inferiores e as medidas de inclinação da sínfise e deslocamento do ponto B. Com relação à espessura da sínfise e a inclinação dos incisivos, não foi encontrada correlação estatisticamente significante. Em relação à comparação entre os tempos estudados, não foram encontradas diferenças estatisticamente significantes. / This research was conducted with the purpose of identifying the buccolingual inclinations of the lower teeth and the morphological characteristics of the mandibular symphysis resulting from the orthodontic decompensation movement. The sample consisted of 30 adults, with class III dentofacial deformity, submitted to presurgical orthodontic treatment. From three-dimensional images generated by cone-beam computed tomography (CBCT) scans, at two different times (initial and before orthognathic surgery), three-dimensional virtual models were obtained and superimposed using automated voxel-based registration at the cranial base and at the mandible to evaluate mandibular rotation, displacement of the chin, B-point displacement, lower molar and incisor decompensation movement and symphysis inclination and thickness. The three-dimensional displacements of landmarks at the symphysis were quantified and visualized with color-coded maps and semitransparent superimpositions using the SlicerCMF 3-1® 4.5.0 software. Pearson\'s correlation test was used to verify the correlation between tooth inclination, symphysis inclination and thickness and B-point displacement. The thickness and inclination of the symphysis were compared between the two different scans using paired Student t test. The measurements showed high reproducibility. The majority of patients presented clockwise rotation of the mandible and displacement of the chin in the posterior and inferior direction. Point B moved in the posterior and superior direction. In addition, the patients presented lower incisors proclination, which was consistent with the movement of tooth decompensation caused by the presurgical orthodontic treatment. Statistically significant correlations were found between the inclination of the lower incisors, symphysis inclination and B-point displacement. Regarding the thickness of the symphysis and the inclination of the incisors, no statistically significant correlation was found. Regarding the comparison between the two studied times, no statistically significant differences were found.
350

Avaliação da descolagem de bráquetes entre as técnicas de colagem direta e indireta /

Martins, Isabela Parsekian January 2019 (has links)
Orientador: Ary dos Santos Pinto / Resumo: Neste estudo investigou-se in vivo a eficácia da técnica de colagem direta comparada a colagem indireta em relação ao número de falhas na colagem que ocorreram durante o tratamento ortodôntico. Foram selecionados cento e vinte pacientes com idades de 13 e 57 anos, de ambos gêneros tratados consecutivamente numa clínica privada nos anos de 2011 a 2017 com aparelho ortodôntico fixo metálico e divididos em dois grupos: grupo A, com 54 indivíduos no qual se realizou a colagem de bráquetes pela técnica direta e o grupo B com 66 indivíduos, no qual se realizou a colagem de bráquetes pela técnica indireta. A comparação estatística entre as duas técnicas de colagem de bráquetes foi baseada no número total de descolagens e no tempo para a primeira descolagem, tendo sido cada paciente observado por 25 meses. Utilizou-se, respectivamente, os testes de Qui-quadrado e de sobrevida de Kaplan-Meier, com a comparação entre as curvas realizada pelo teste de Log-rank. Foi empregado o modelo de regressão de Cox para avaliar a ação conjunta dos fatores de interesse sobre o tempo da primeira descolagem. Adotou-se sempre o nível de significância de 5% para a tomada de decisão. No período de avaliação de 25 meses após a colagem dos bráquetes nos arcos superior e inferior, ocorreu diferença significativa de 1,6% na porcentagem de quedas de bráquetes pela técnica de colagem indireta em relação à direta, porém, a baixa porcentagem destas quedas indicou a eficácia da técnica de colagem direta de 97,3% ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: In this in vivo study it was investigated the effectiveness of the direct bonding technique compared to indirect one to evaluate the number of bond failures that occurred during orthodontic treatment. One hundred and twenty patients aged 13 to 57 years, of both genders consecutively treated in a private practice in the years 2011 to 2017 with fixed metallic orthodontic appliance were selected and divided into two groups: group A, with 54 individuals in which the brackets were bonded by the direct technique and group B with 66 individuals, in which the brackets were bonded by the indirect technique. The statistical comparison between the two techniques of bracket bonding were based on the total number of bond failures and the time to first bond failure, with each patient being observed for 25 months. The chi-square test was used to compare the survival rates of the brackets bonded with direct and indirect bonding. The log-rank test was used to compare the Kaplan-Meier survival curves of both bonding methods. The Cox regression model was used to evaluate the joint association of the factors of interest on the time to first bond failure. The level of significance of 5% was adopted for decision-making. In the evaluation period of 25 months after the bonding of the brackets in the upper and lower arches, there was a significant difference of 1.6% in the percentage of bracket failure in the indirect bonding technique in relation to the direct one. The low percentages of these failu... (Complete abstract click electronic access below) / Doutor

Page generated in 0.0348 seconds