• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 10
  • 9
  • Tagged with
  • 24
  • 24
  • 21
  • 16
  • 10
  • 10
  • 10
  • 9
  • 9
  • 8
  • 8
  • 7
  • 7
  • 7
  • 7
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Supervisory control scheme for FACTS and HVDC based damping of inter-area power oscillations in hybrid AC-DC power systems

Hadjikypris, Melios January 2016 (has links)
Modern interconnected power systems are becoming highly complex and sophisticated, while increasing energy penetrations through congested inter-tie lines causing the operating point approaching stability margins. This as a result, exposes the overall system to potential low frequency power oscillation phenomena following disturbances. This in turn can lead to cascading events and blackouts. Recent approaches to counteract this phenomenon are based on utilization of wide area monitoring systems (WAMS) and power electronics based devices, such as flexible AC transmission systems (FACTS) and HVDC links for advanced power oscillation damping provision. The rise of hybrid AC-DC power systems is therefore sought as a viable solution in overcoming this challenge and securing wide-area stability. If multiple FACTS devices and HVDC links are integrated in a scheme with no supervising control actions considered amongst them, the overall system response might not be optimal. Each device might attempt to individually damp power oscillations ignoring the control status of the rest. This introduces an increasing chance of destabilizing interactions taking place between them, leading to under-utilized performance, increased costs and system wide-area stability deterioration. This research investigates the development of a novel supervisory control scheme that optimally coordinates a parallel operation of multiple FACTS devices and an HVDC link distributed across a power system. The control system is based on Linear Quadratic Gaussian (LQG) modern optimal control theory. The proposed new control scheme provides coordinating control signals to WAMS based FACTS devices and HVDC link, to optimally and coherently counteract inter-area modes of low frequency power oscillations inherent in the system. The thesis makes a thorough review of the existing and well-established improved stability practises a power system benefits from through the implementation of a single FACTS device or HVDC link, and compares the case –and hence raises the issue–when all active components are integrated simultaneously and uncoordinatedly. System identification approaches are also in the core of this research, serving as means of reaching a linear state space model representative of the non-linear power system, which is a pre-requisite for LQG control design methodology.
22

Control of Dynamically Assisted Phase-shifting Transformers

Johansson, Nicklas January 2008 (has links)
In this thesis, controllers for power oscillation damping, transient stability improvement and power flow control by means of a Controlled Series Compensator (CSC) and and a Dynamic Power Flow Controller (DPFC) are proposed. These devices belong to the group of power system components referred to as Flexible AC Transmission System (FACTS) devices. The developed controllers use only quantities measured locally at the FACTS device as inputs, thereby avoiding the risk of interrupted communications associated with the use of remote signals for control. For power systems with one dominating, poorly damped inter-area power oscillation mode, it is shown that a simple generic system model can be used as a basis for damping- and power flow control design. The model for control of CSC includes two synchronous machine models representing the two grid areas participating in the oscillation and three reactance variables, representing the interconnecting transmission lines and the FACTS device. The model for control of DPFC is of the same type but it also includes the phase shift of the internal phase-shifting transformer of the DPFC. The key parameters of the generic grid models are adaptively set during the controller operation by estimation from the step responses in the FACTS line power to the changes in the line series reactance inserted by the FACTS device. The power oscillation damping controller is based on a time-discrete, non-linear approach which aims to damp the power oscillations and set the desired power flow on the FACTS line by means of two step changes in the line reactance separated in time by half an oscillation cycle. A verification of the proposed controllers was done by means of digital simulations using power system models of different complexities. The CSC and DPFC controllers were shown to significantly improve the small-signal- and transient stability in one four-machine system of a type commonly used to study inter-area oscillations. The CSC controller was also tested for 18 different contingencies in a 23-machine system, resulting in an improvement in both the system transient stability and the damping of the critical oscillation mode. / QC 20101112
23

Aplicação do algoritmo genético adaptativo com hipermutação no ajuste dos parâmetros dos controladores suplementares e dispositivo FACTS IPFC /

Cordero Bautista, Luis Gustavo January 2019 (has links)
Orientador: Percival Bueno de Araujo / Resumo: As perturbações ou variações de carga produzem oscilações eletromecânicas que devem ser amortecidas o mais rápido possível para garantir confiabilidade e estabilidade da rede. Neste trabalho apresenta-se uma análise do dispositivo FACTS Interline Power Flow Controller (IPFC) e o controlador Proporcional Integral (PI) no gerenciamento dos fluxos de potência e a influência dos Estabilizadores do Sistema de Potência (ESP) e do IPFC Power Oscillation Damping (POD) sobre a estabilidade do sistema elétrico de potência. Neste trabalho enfoca-se nos estudos de estabilidade a pequenas perturbações usando um Algoritmo Genético Adaptativo com Hiper-mutação (AGAH) para ajustar os parâmetros dos controladores suplementares de amortecimento, o Estabilizador de sistema de potência (ESPs) e o Power Oscillation Damping (POD) em forma coordenada. O AGAH tem como objetivo encontrar os parâmetros ótimos do controlador para melhorar o amortecimento fraco das oscilações de baixa frequência locais e inter-área. Neste trabalho representa-se o sistema de elétrico de potência com a inclusão do dispositivo Interline Power Flow Controller com o modelo de sensibilidade de corrente (MSC). Considera-se como sistema teste o sistema Simétrico de Duas Áreas e o sistema New England como o intuito de avaliar o algoritmo proposto. As simulações são feitas no ambiente do MatLab. Por fim, apresenta-se a comparação do algoritmo genético com o desempenho do algoritmo proposto. / Abstract: Small-magnitude disturbances happen to produce electro-mechanical oscillations which should be damped as quickly as possible to ensure reliability and stability of the network. This work presents an analysis of Interline Power Flow Controller (IPFC) FACTS device and PI controller to control and manage power flow and also how Power System Stabilizers and IPFC Power Oscillations Damping (POD) controller influence over an electric power system stability. This work focuses on small-signal stability studies using an Adaptive Genetic Algorithm with Hyper-mutation (AGAH) in order to tune controller parameters in a coordinated way ensuring proper damping. AGAH aims to find optimal controller parameters to enhance the poor damping of local and inter-area low frequency oscillations. This works represents the electric power system and Interline Power Flow Controller device by a current sensitivity model (CSM). This paper considers two areas 14 bus symmetrical power system and New England power system in order to assess proposed algorithm. Coding and Simulations take place in MatLab platform. AGAH and GA get compared by time convergence and performance. This paper shows AGAH is an interesting optimization technique which outweighs GA. / Mestre
24

Development of PMSM and drivetrain models in MATLAB/Simulink for Model Based Design / Utveckling av PMSM och drivlinemodeller i MATLAB / Simulink för modellbaserad design

Sivaraman, Gokul January 2021 (has links)
When developing three-phase drives for Electric Vehicles (EVs), it is essential to verify the controller design. This will help in understanding how fast and accurately the torque of the motor can be controlled. In order to do this, it is always better to test the controller using the software version of the motor or vehicle drivetrain than using actual hardware as it could lead to component damage when replicating extreme physical behavior. In this thesis, plant modelling of Permanent Magnet Synchronous Machine (PMSM) and vehicle drivetrain in MATLAB/Simulink for Model Based Design (MBD) is presented. MBD is an effective method for controller design that, if adopted can lead to cost savings of 25%-30% and time savings of 35%-40% (according to a global study by Altran Technologies, the chair of software and systems engineering and the chair of Information Management of the University of Technology in Munich) [1]. The PMSM plant models take effects like magnetic saturation, cross- coupling, spatial harmonics and temperature into account. Two PMSM models in d-q frame based on flux and inductance principles were implemented. Flux, torque maps from Finite Element Analysis (FEA) and apparent inductance from datasheets were used as inputs to the flux- and inductance-based models, respectively. The FEA of PMSM was done using COMSOL Multiphysics. The PMSM model results were compared with corresponding FEA simulated results for verification. A comparison of these PMSM models with conventional low fidelity models has also been done to highlight the impact of inclusion of temperature and spatial harmonics. These motor models can be combined with an inverter plant model and a controller can be developed for the complete model. Low frequency oscillations of drivetrain in EVs lead to vibrations which can cause discomfort and torsional stresses. In order to control these oscillations, an active oscillation damping controller can be implemented. For implementation of this control, a three-mass mechanical plant model of drivetrain with an ABS (Anti-lock Braking System) wheel speed sensor has been developed in this thesis. Analysis of the model transfer function to obtain the pole zero maps was performed. This was used to observe and verify presence of low frequency oscillations in the drivetrain. In order to include the effects of ABS wheel speed sensor and CAN communication, a model was developed for the sensor. / Testning av regulatorernas inställningar med hänsyn till snabbhet och noggrannhet i momentreglering är avgörande i trefasiga drivsystem för elektriska fordon. Oftast är det bättre att simulera i stället för att utföra experimentella tester där komponenter kan skadas på grund av fysisk stress. Detta kallas för Model Based Design (MBD). MBD är an effektiv metod för utformningen av styrningen som kan leda till kostnadsbesparingar på 25%-30% och tidsbesparingar på 35%-40% enligt en studie från Altran Technologies i samarbete med Tekniska universitet i München, TUM. Detta examensarbete behandlar en modell för en synkronmaskin med permanentmagneter (PMSM) samt en modell för drivlinan utvecklad i Matlab/Simulink för MBD. PMSMs modellen inkluderar magnetisk mättnad och tvärkoppling, MMF övervågor och temperatur. Två PMSM modeller har utvecklats. Den första baseras på magnetiskt flöde som erhålls från finita element beräkningar i COMSOL Multiphysics medan den andra bygger på induktanser givna från datablad. En jämförelse av dessa PMSM-modeller med konventionella low fidelity-modeller har också gjorts för att illustrera påverkan temperaturberoende och MMF övervågor. Modellerna kan kombineras med en växelriktarmodell för att utveckla en hel styrenhet. Lågfrekventa oscillationer i drivlinan leder till vibrationer som kan orsaka vridspänningar och försämra komforten i elfordonet. En aktiv dämpningsregulator kan implementeras för att kontrollera spänningarna men en mekanisk drivlinemodell med tre massor och en ABS (anti-lock braking system) hastighetssensor behövs. Den mekaniska modellen har implementerats och analyserats även beaktande en modell för en CAN kommunikationskanal. Oscillationer med låg frekvens kunde observeras i modellen.

Page generated in 0.1582 seconds