Spelling suggestions: "subject:"osseointegration""
191 |
Avaliação do plasma de argônio na integração dos tecidos moles e duros aos implantes e componentes protéticos: estudo randomizado em cães / Evaluation of argon plasma in the integration of soft and hard tissues to implants and prosthetic components: a randomized study in dogsMartins Neto, Evandro Carneiro 07 December 2017 (has links)
Diversas aplicações do plasma de argônio tem sido encontradas na literatura. Na odontologia, suas aplicações se referem a capacidade de limpeza de componentes e aumento da energia de superfície. Os tratamentos para melhorar a energia de superfície são estudados com objetivo de criar um ambiente mais favorável para a adesão celular. Este estudo teve como objetivo avaliar histologicamente as mudanças nos tecidos moles e duros após a inserção de implantes e pilares de titânio limpos e ativados com plasma de argônio. Foram instalados 64 implantes e pilares em 8 cães Beagle, sendo randomizados em dois grupos: tratados com plasma de argônio ou não tratados. Dois tempos experimentais foram realizados: 4 e 8 semanas. Após esse período, os animais foram sacrificados, as mandíbulas foram divididas em blocos individuais e processados para confecção de lâminas para análise histológica. Na análise dos pilares, não houve diferença estatística entre os grupos, apesar de maiores níveis de osso marginal nos locais de teste em comparação com os locais de controle. Em relação aos implantes de titânio, as diferenças entre teste e controle, principalmente no período de 8 semanas, podem sugerir que o uso de plasma de argônio poderia melhorar a integração dos tecidos periimplantares à superficie dos implantes. / Several applications of argon plasma have been found in the literature. In dentistry, its applications refer to the ability to clean components and increase surface energy. Treatments for enhancing surface energy were studied in an effort to create a more favorable environment for cell adhesion. This study aimed to histologically evaluate changes in soft and hard tissues after insertion of implants and titanium abutments cleaned and activated with argon plasma. 64 implants and abutments were installed in 8 Beagle dogs, and were randomized into two groups: treated with argon plasma or untreated. Two experimental times were performed: 4 and 8 weeks. After this period, the animals were sacrificed, the jaws were divided into individual blocks and processed for histological analysis. In the analysis of abutments, there was no statistical difference between groups, despite higher levels of marginal bone in test sites compared to the control sites. Regarding titanium implants, the differences between test and control, especially in the 8-week period, may suggest that the use of argon plasma could improve the integration of peri-implant tissues to the implant surface.
|
192 |
Avaliação da osseointegração promovida por implantes jateados por Al2O3 : análises histológica e histométrica em cães /Ponzoni, Daniela. January 2004 (has links)
Orientador: Paulo Sérgio Perri de Carvalho / Resumo: A formação de uma interface osseointegrada é mais previsível quando osso denso e saudável está em contato com a superfície do implante no momento da instalação. Porém, a colocação de implantes imediatos após exodontia apresenta inúmeras vantagens, entre elas a preservação da arquitetura óssea e gengival dos processos alveolares, além da diminuição do tempo cirúrgico. A utilização de uma superfície modificada proporciona um maior contato ósseo com o implante; baseado em princípios biológicos. A proposta deste trabalho é avaliar qualitativa e quantitativamente a interface entre osso e os implantes de titânio, jateados por Al2O3 instalados imediatamente após exodontias, em cães. Os implantes foram instalados nos alvéolos de pré-molares mandibulares bilateralmente em quatro cães. Foram instalados quatro implantes para cada animal (4mm de diâmetro e 10mm de comprimento) do Sistema Colosso (Emfils®), sendo dois de cada lado da mandíbula. Os animais foram sacrificados aos 120 dias pós-operatórios. As peças foram desmineralizadas, e os implantes removidos. Três implantes foram perdidos, três fibrointegrados e dez osseointegrados. A análise quantitativa foi realizada considerando-se cinco roscas apicais e o fundo do implante. A análise histológica mostrou tecido ósseo saudável em fase de maturação em íntimo contato com os implantes osseointegrados. Na análise histométrica, observou-se um contato ósseo de 76% nos implantes osseointegrados. / Abstract: An osseointegrated interface could be predictable when dense and healthy bone is in contact with the titanium implant surface at the moment of implant insertion. However, immediate implantation after exodontia presents numerous advantages, among them, maintenance of bone and gingival architecture and decrease of operative time. The use of an implant with modified surface favors bone contact, according to biological principles. This study aims to evaluate the interface between bone and Al2O3 blasted titanium implants installed in 4 dogs immediately after bilateral exodontias of mandibular premolars. Four Emfils® implants (Sistema Colosso - 4mm diameter; 10mm length), 2 per side, were used in each dog. Animals were sacrificed after 120 days of surgery and the samples removed. Bone was decalcified and the implants removed. Three implants were lost, 3 had fibrointegration and 10 osseointegrated. Histological analysis showed a healthy tissue in process of maturation interfacing osseointegrated implants. Quantitative analysis was focused in 5 apical threads and the bottom of the implants. It was shown a contact of 76% between bone and the implants. Osseointegration was achieved around Al2O3 blasted titanium implants installed immediately after exodontias. / Doutor
|
193 |
Estudo histomorfométrico de implantes craniofaciais em coelhos / Histomorphometric analysis of craniofacial implants placed in rabbitsSantos Júnior, João Ferreira dos [UNIFESP] 25 November 2010 (has links) (PDF)
Made available in DSpace on 2015-07-22T20:50:10Z (GMT). No. of bitstreams: 0
Previous issue date: 2010-11-25 / Objetivo: Análise histomorfométrica de implantes craniofaciais de diâmetros e formatos diferentes com superfície lisa e porosa em tíbia de coelhos. Método: Foram utilizados nessa pesquisa oito coelhos, adultos, fêmeas, albinos, raça Nova Zelândia. Instalamos 40 implantes craniofaciais com formatos cilíndricos (3,75 e 5,0 mm de diâmetro) e cônico (4,3 mm de diâmetro) ambos com 5 mm de comprimento. Os coelhos foram sacrificados 12 semanas, após a instalação dos implantes e as amostras de tecido ósseo submetidos à análise histomorfométrica, para avaliação do contato osso-implante e quantidade de osso formado entre as roscas dos implantes. Resultados: Os valores globais (média e desvio-padrão) do contato osso-implante dos implantes com superfície porosa foi de 73,77% ±6,25 e os implantes com superfície lisa 59,79% ±8,32. Individualmente os valores do contato osso-implante foram os seguintes: o implante poroso de 5,0 mm 72,67% ±7,44, implante liso de 5,0 mm 58,33% ±7,01, implante poroso 4,3 mm 76,80% ±5,58, implante liso 4,3 mm 61,26% ±9,78 e implante poroso 3,75 mm 71,84% ±5,24. Conclusão: existe maior valor estatisticamente significante (p<0,001) de contato osso-implante nos implantes com superfície tratada. Não existe diferença estatisticamente significante, quanto ao contato osso-implante, entre os diferentes tamanhos de implante (3,75 mm / 4,3 mm / 5,0 mm) e formatos dos mesmos (cônico e cilíndrico). / Purpose: Histomorphometric analysis of craniofacial implants of different shapes and diameters, with machined and porous surfaces, placed in the tibia of rabbits. Method: In this study, 40 craniofacial implants with cylindrical shapes (3.75 and 5.0 mm in diameter) and conical (4.3 mm in diameter) both with 5 mm in length were implanted in the tibia of 8 adult female New Zealand white rabbits. The animals were sacrificed 12 weeks after installation of implants. Bone specimens were prepared for histomorphometric assessment of the bone-to-implant contact and the bone volume formation between implant threads. Results: The overall bone-to-implant contact values (mean and standard deviation) were 73.77 ± 6.25% with porous surface implants and 59.79 ± 8.32% with machined surface implants. Individual group values of bone-to-implant contact were as follows: 5.0 mm porous implant 72.67 ± 7.44%; 5.0 mm machined implant 58.33 ± 7.01%; 4.3 mm porous implant 76.80 ± 5.58%; 4.3 mm machined implant 61.26 ± 9.78%; and 3.75 mm porous implant 71.84 ± 5.24%. Conclusion: There was statistically significant greater bone-to-implant contact values with porous surface implants (p <0.001). There was no statistically significant difference on the bone-to-implant contact between different implant sizes (3.75 mm / 4.3 mm / 5.0 mm) and shapes (cylindrical and conical). / TEDE / BV UNIFESP: Teses e dissertações
|
194 |
Osseointegração de implantes de titânio com modificação da superfície por ablação a laser e recobrimento por hidroxiapatita biomimética: estudo biomecânico e histomorfométrico em tíbia de coelhosFaeda, Rafael Silveira [UNESP] 15 June 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:33:00Z (GMT). No. of bitstreams: 0
Previous issue date: 2010-06-15Bitstream added on 2014-06-13T21:05:33Z : No. of bitstreams: 1
faeda_rs_dr_arafo.pdf: 15247078 bytes, checksum: c62d1ae9dfd05690aa2ca25b49d04945 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O sucesso dos sistemas modernos de implantes dentais tem sido relacionado ao desenvolvimento do design e das características de superfícies dos implantes. O propósito do presente estudo foi avaliar duas novas superfícies de implantes (modificada por laser - LMS e recoberta por hidroxiapatita biomimética - HA), comparando-as a outro implante comercial, (superfície usinada – MS). Um total de 144 implantes (3,75 x 10mm), 48 de cada superfície, foram instalados na tíbia de coelhos e avaliados após 4, 8 e 12 semanas. Após os períodos de cicatrização os animais foram sacrificados, um dos implantes expostos e a força necessária para derosquea-los foi aferida por um torquímetro analógico. O outro implante foi removido com o tecido ósseo peri-implantar e processado por corte histológico calcificado para análise histomorfométrica do contato osso-implante (BIC%) e da área óssea entre espiras (BBT%). Em 4 e 8 semanas, os implantes HA apresentaram valor de torque de remoção estatisticamente superior (p<0,05) quando comparado aos demais, sendo o mesmo observado para os implantes LMS quando comparados aos MS. Após 12 semanas, os implantes HA e LMS foram estatisticamente superiores aos implantes MS. Por outro lado, a análise do contato osso-implante mostrou que na região cortical, os implantes LMS e HA foram estatisticamente superiores ao MS para todos os períodos de cicatrização, sem diferença estatística entre LMS e HA. A análise histomorfométrica mostrou que, quando comparados na região endosteal, os implantes LMS e HA foram estatisticamente superiores ao MS no período inicial de cicatrização. Embora os implantes LMS e HA não apresentassem diferenças estatísticas entre eles, uma tendência de maiores valores de BIC% para HA na região endosteal foi observada em todos os períodos do estudo.Os resultados deste estudo mostram que apesar de não haver diferença... / Purpose: Considering the great biological potential of the association between laser ablation and hydroxyapatite thin layer coatings to create an interesting bioactive environment on titanium dental implants, the aim of the present study was to investigate, by histomorphometrical and removal torque analysis, the histological effects of a surface treatment created by laser-ablation (Nd:YAG) and, later, thin deposition of HA particles by a chemical process compared to implants with only laser-ablation and implants with machined surfaces. Materials and Methods: Forty-eight rabbits received two implant by tibiae of the following surfaces: Machined surface (MS), laser-modified surface (LMS) and biomimetic hydroxiapatite coated surface (HA). After 4, 8 and 12 weeks of healing, one implant was exposed, and the needed force to unscrew measured using an analogical torque gauge. The other implant and surrounding bone was removed and prepared by a calcified histological process. The percentage of bone-to-implant contact (BIC) and the bone area formed between the threads (BBT) were evaluated separately to the cortical and endosteal region. Results: The difference was statistically significant (P < .05) between the LMSMS and HA-MS surfaces in all periods of evaluation, and between LMS-HA to 4 and 8 weeks of healing. The surface characterization showed a deep, rough, and regular topography provided by the laser conditioning, that was followed by the HA coating. Average BIC percentage in the cortical region was significantly higher (P<0.001) on the LMS and HA implants, compared with MS ones for all periods of healing, having no statistical differences between LMS and HA. When compared in the endosteal area, the LMS and HA implants showed statistically higher (P<0.01) BIC percentage values than MS at the initial periods of healing (LMS after 4 weeks and HA after 4 and 8 weeks, respectively)... (Complete abstract click electronic access below)
|
195 |
Reparo ósseo peri-implantar em tíbias de ratos espontaneamente hipertensos (SHR) tratados com losartan: análise biomecânica, molecular, microtomográfica, dinâmica óssea por fluorocromos, imunoistoquímica e histológica / Peri-implant bone healing in the tibia of spontaneously hypertensive rats (SHR) treated with losartan: a biomechanical, molecular, microtomography, bone dynamics by fluorochromes, immunohistochemical and histological analysisSantos, Gabriel Mulinari dos [UNESP] 09 February 2018 (has links)
Submitted by GABRIEL MULINARI DOS SANTOS (gabriel_mulinari@hotmail.com) on 2018-02-14T10:31:03Z
No. of bitstreams: 1
Dissertacao_Gabriel_Repositorio.pdf: 2013798 bytes, checksum: e83e70bf61f06fb298685c59bc39ea6f (MD5) / Approved for entry into archive by Claudio Hideo Matsumoto null (claudio@foa.unesp.br) on 2018-02-14T18:04:12Z (GMT) No. of bitstreams: 1
santos_gm_me_araca_int.pdf: 2013798 bytes, checksum: e83e70bf61f06fb298685c59bc39ea6f (MD5) / Made available in DSpace on 2018-02-14T18:04:12Z (GMT). No. of bitstreams: 1
santos_gm_me_araca_int.pdf: 2013798 bytes, checksum: e83e70bf61f06fb298685c59bc39ea6f (MD5)
Previous issue date: 2018-02-09 / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Introdução: A hipertensão está associada a doenças cardiovasculares, mas também com
alterações na qualidade óssea. A hipertensão, portanto, pode ser um fator de risco para a
osseointegração. Estudos pré-clínicos sugerem que o losartan, um bloqueador dos receptores
da angiotensina II amplamente utilizado para tratar a hipertensão, tem um efeito benéfico na
consolidação do enxerto. No entanto, o efeito da hipertensão e do losartan na osteointegração
permanece desconhecido.
Material e Métodos: Aqui utilizamos ratos ratas espontaneamente hipertensivos (SHR) e ratos
Wistar albinus normotensos que receberam losartan (30 mg / kg, p.o.) ou não tratados. Após
uma semana, mini-implantes de titânio foram inseridos na tíbia. Sessenta dias após a
implantação, a estabilidade do implante foi avaliada pela medição de torque de remoção
considerada o ponto final primário. A tomografia computadorizada micro e a análise
histomorfométrica foram parâmetros secundários.
Resultados: o Losartan aumentou o torque de remoção no grupo SHR hipertenso para os níveis
dos controles Wistar. Enquanto os parâmetros corticais da osseointegração permaneceram
inalterados, losartan aumentaram a formação do osso medular. A micro tomografia
computorizada revelou maior volume ósseo por volume de tecido e espessura trabecular nos
ratos SHR tratados com losartan. A análise histomorfométrica mostrou ainda que o losartan
aumentou significativamente a espessura do osso recém-formado na área medular em ratos
SHR hipertensos. O losartan não alterou significativamente os parâmetros de osseointegração
em ratos normotensos.
Conclusões: Os dados apresentados sugerem que o antagonista dos receptores da
angiotensina II losartan aumenta os parâmetros medulares da osseointegração no modelo da
tíbia de ratos espontaneamente hipertensos. / Background: Hypertension is associated with cardiovascular diseases but also with alterations in bone
quality. Hypertension therefore might be a risk factor for osseointegration. Preclinical studies suggest
that losartan, an angiotensin II receptor blocker widely used to treat hypertension, has a beneficial
effect in graft consolidation. However, the effect of hypertension and losartan on osseointegration
remains unknown.
Methods: Here we used spontaneously hypertensive rats (SHR) and normotensive Wistar albinus rats
receiving losartan (30 mg/kg, p.o.) or left untreated. After one week, titanium miniscrews were inserted
into the tibia. Sixty days after implantation, implant stability was evaluated by removal torque
measurement considered the primary endpoint. Micro computed tomography and histomorphometric
analysis were secondary endpoints.
Results: Losartan increased the removal torque in the hypertensive SHR group to levels of the Wistar
controls. While the cortical parameters of osseointegration remained unchanged, losartan increased
medullary bone formation. Micro computed tomography revealed a higher bone volume per tissue
volume and trabecular thickness in the SHR rats treated with losartan. Histomorphometric analysis
further showed that losartan significantly increased the thickness of newly formed bone in medullary
area in hypertensive SHR rats. Losartan did not significantly alter the parameters of osseointegration in
normotensive rats.
Conclusions: The data presented suggest that the angiotensin II receptor antagonist losartan increases
the medullary parameters of osseointegration in a tibia model of spontaneously hypertensive rats. / 16/03245-2
|
196 |
Avaliação de implantes de titânio com modificação da superfície por abrasão a laser ou recobrimento por hidroxiapatita biomimétrica. Estudo biomecânico em tíbia de coelhosFaeda, Rafael Silveira [UNESP] 16 March 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:03Z (GMT). No. of bitstreams: 0
Previous issue date: 2006-03-16Bitstream added on 2014-06-13T20:08:38Z : No. of bitstreams: 1
faeda_rs_me_arafo.pdf: 1508242 bytes, checksum: 76a3276ed9cd6a6e7947d633681c4217 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Universidade Estadual Paulista (UNESP) / O sucesso dos sistemas modernos de implantes dentais tem sido relacionado ao desenvolvimento do design e das características de superfícies dos implantes. O propósito do presente estudo foi avaliar duas novas superfícies de implantes (modificada por laser - SML e recoberta por hidroxiapatita biomimética - HA), comparando-as a outros dois implantes comerciais, (superfície usinada - SU e modificada por jateamento e ataque ácido - SMC). Um total de 96 implantes (3,75 x 10mm), 24 de cada superfície, foram instalados na tíbia de coelhos e avaliados após 4, 8 e 12 semanas. Após os períodos de cicatrização os animais foram sacrificados, os implantes expostos e a força necessária para derosquea-los foi aferida por um torquímetro analógico. Em 4 e 8 semanas, os implantes HA apresentaram valor de torque de remoção estatisticamente superior (p<0,05) quando comparado aos demais, sendo o mesmo observado para os implantes SML quando comparados aos SU. Após 12 semanas, os implantes HA e SML foram estatisticamente superiores aos implantes SU. Os resultados deste estudo sugerem que os implantes HA foram superiores aos demais nos períodos iniciais, obtendo uma estabilidade satisfatória com 4 semanas de implantação. Os implantes SML foram superiores aos SU em todos os períodos avaliados, porém não apresentando diferenças quando com parados aos SMC. / The success of modern dental implant systems has been associated with the development of implant designs and surface characteristic. The purpose of this study was to evaluate two new implant surfaces (laser-modified - LSM and biomimetic-hydroxyapatite coating - HA) comparing them with two other commercial implants (machined surface -MS and modified by sandblasted and acid etched - MCS). A total of 96 implants (3,75 x 10mm), 24 of each surface, were placed in rabbit tibia being evaluated after 4, 8 and 12 weeks. After the healing periods, the animals were sacrificed, the implants sites were exposed, and the needed force to unscrew the implants was measured using an analogical torque gauge. At 4 and 8 weeks, the HA implants removal torque was statistically greater (p<0,05) in comparison with the others, being the same observed to LSM when compared with MS. After 12 weeks, the HA and LSM implants were statistically greater just when compared with MS. The results of this study suggest that the HA implants were superior to the other at the initial periods, having a satisfactory stability with 4 weeks post-implantation. The LSM implants were superior to MS at all periods evaluated, but having no difference when compared with MCS.
|
197 |
Efeito do tratamento de superfície na osseointegração de implantes dentários da liga TI-7,5Mo /Oliveira, João Augusto Guedes de. January 2012 (has links)
Orientador: Ana Paula Rosifini Alves Claro / Coorientador: Maria Cristina Rosifini Alves Rezende / Banca: Carlos Roberto Grandini / Banca: Estevão Tomomitsu Kimpara / Banca: Mônica Beatriz Mathor / Banca: Ana Christina Alves Rezende / Resumo: Os Biomateriais Metálicos são utilizados para reforçar ou para restaurar a forma e função de tecidos duros. Os implantes e próteses são utilizados para substituir ombros, joelhos, quadris e dentes perdidos entre outros. Nos últimos anos, varias ligas de titânio para aplicações biomédicas foram avaliadas. Neste trabalho, a influência do tratamento de superfície biomimético na osseointegração de implantes dentários da liga Ti-7,5Mo foi avaliada. Os lingotes foram obtidos a partir de titânio e molibdênio utilizando um forno a arco voltaico. Eles foram submetidos a tratamento térmico e conformados a frio em prensa rotativa. Posteriormente foram confeccionados implantes (2,0 mm de diâmetro e 2,5 mm de comprimento) sob medida os quais submetidos ao tratamento de superfície biomimético. Os implantes foram inseridos e analisados histológica realizada após 28 dias. A caracterização microestrutural e mecânica da liga Ti-7,5Mo também foi realizada. Aliga Ti-7,5Mo exibiu baixo modulo de elasticidade e elevada relação resistência/modulo. O uso do tratamento de superfície biomimético promoveu um aumento da osseointegração sobre a superfície dos implantes / Abstract: Metallic biomaterials are used to reinforce or to restore form and function of hard tissues. Implants and prosthesis are used to replace shoulders, knees, hips and teeth. In the last years, several titanium alloys for biomedical applications have been studied. In the present work, influence of biomimetic surface treatment in osseointegration of Ti-7.5Mo dental implant was evaluated. Ingots were obtained from titanium and molybdenum by using an arc-melting furnace. They were submitted to heat treatment and cold worked by swaging. Then, screw-shaped implants (2.0 mm diameter by 2.5 mm length) were custom made and they were submitted biomimetic surface treatment. Implants were implanted in the rat's femur and histological analysis was realized after 28 days. Also, microstructural and mechanical properties of Ti-7.5Mo alloy were evaluated. Ti-7.5Mo showed low elasticity modulus and higher ratio strength/modulus. Results obtained suggest that Ti-7.5Mo exhibited excellent bulk properties. The use of the biomimetic surface treatment was able to promote an increase of osseointegration on surface of dental implants / Doutor
|
198 |
Avaliação clínica e radiográfica dos tecidos peri-implantares de implantes osseointegrados que receberam carregamento imediato /Lemo, Vagner Samy. January 2004 (has links)
Resumo: Um estudo clínico e radiográfico foi realizado para analisar o resultado do tratamento com implantes unitários e unidos (prótese protocolo), instalados e imediatamente carregados. O estudo inclui 10 pacientes que receberam 10 implantes e próteses provisórias unitárias e 5 pacientes que receberam 25 implantes, 5 implantes cada paciente entre os foramens mentoniano, estes foram unidos e receberam uma prótese tipo protocolo. Todas as próteses foram instaladas imediatamente após a cirurgia. Em um intervalo de 6 e 12 meses todos os pacientes foram radiografados e avaliados clinicamente. Não foram registradas perdas no grupo de implantes unitários e o grupo de implantes que recebeu prótese protocolo perdeu 2 implantes. Não houve alterações nos parâmetros periodontais (clínicos e radiográficos) entre os períodos de 6 e 12 meses, e as diferenças encontradas entre os implantes unitários e unidos, parecem estar mais relacionados ao local de inserção (maxila - mandíbula). Podemos concluir que a carga imediata é um procedimento previsível tanto para implantes unitários como em implantes unidos. / Abstract: The study includes 10 patient that received 10 implants and unitary temporary prostheses and 5 patient that received 25 implants, 5 implants each patient one in the area previous of jawbone, these were united and they received a prosthesis type protocol. All of the prostheses were installed immediately after the surgery. In an interval of 6 and 12 months all the patients were x-rayed and evaluated clinically. Losses were not registered in the group of unitary implants and the group of implants that it received prosthesis protocol lost 2 implants. There were not alterations in the periodontal parameters (clinical and radiographic) among the periods of 6 and 12 months, and the differences found among the unitary and united implants, they seem to be more related to the insert place (jawbone - jaw). We can conclude that the immediate load is a previsible procedure so much for unitary implants as in united implants. / Orientador: Elcio Marcantonio / Coorientador: Elcio Marcantonio Junior / Banca: Roberto Henrique Barbeiro / Banca: Wilson Trevisan Junior / Mestre
|
199 |
Avaliação do plasma de argônio na integração dos tecidos moles e duros aos implantes e componentes protéticos: estudo randomizado em cães / Evaluation of argon plasma in the integration of soft and hard tissues to implants and prosthetic components: a randomized study in dogsEvandro Carneiro Martins Neto 07 December 2017 (has links)
Diversas aplicações do plasma de argônio tem sido encontradas na literatura. Na odontologia, suas aplicações se referem a capacidade de limpeza de componentes e aumento da energia de superfície. Os tratamentos para melhorar a energia de superfície são estudados com objetivo de criar um ambiente mais favorável para a adesão celular. Este estudo teve como objetivo avaliar histologicamente as mudanças nos tecidos moles e duros após a inserção de implantes e pilares de titânio limpos e ativados com plasma de argônio. Foram instalados 64 implantes e pilares em 8 cães Beagle, sendo randomizados em dois grupos: tratados com plasma de argônio ou não tratados. Dois tempos experimentais foram realizados: 4 e 8 semanas. Após esse período, os animais foram sacrificados, as mandíbulas foram divididas em blocos individuais e processados para confecção de lâminas para análise histológica. Na análise dos pilares, não houve diferença estatística entre os grupos, apesar de maiores níveis de osso marginal nos locais de teste em comparação com os locais de controle. Em relação aos implantes de titânio, as diferenças entre teste e controle, principalmente no período de 8 semanas, podem sugerir que o uso de plasma de argônio poderia melhorar a integração dos tecidos periimplantares à superficie dos implantes. / Several applications of argon plasma have been found in the literature. In dentistry, its applications refer to the ability to clean components and increase surface energy. Treatments for enhancing surface energy were studied in an effort to create a more favorable environment for cell adhesion. This study aimed to histologically evaluate changes in soft and hard tissues after insertion of implants and titanium abutments cleaned and activated with argon plasma. 64 implants and abutments were installed in 8 Beagle dogs, and were randomized into two groups: treated with argon plasma or untreated. Two experimental times were performed: 4 and 8 weeks. After this period, the animals were sacrificed, the jaws were divided into individual blocks and processed for histological analysis. In the analysis of abutments, there was no statistical difference between groups, despite higher levels of marginal bone in test sites compared to the control sites. Regarding titanium implants, the differences between test and control, especially in the 8-week period, may suggest that the use of argon plasma could improve the integration of peri-implant tissues to the implant surface.
|
200 |
Comparação entre implantes unitários de superfície tratada e não tratada por sub-tração radiográfica digital em protocolos de carga imediata e convencional / Comparison between single-tooth treated and non treated surface implants by digital subtraction radiography on immediate and con-ventional loading protocolsCARNEIRO, Luciano Sandoval 27 March 2009 (has links)
Made available in DSpace on 2014-07-29T15:21:59Z (GMT). No. of bitstreams: 1
Dissertacao - Luciano Sandoval Carneiro.pdf: 579690 bytes, checksum: 7c2af9622df94b48e0c190f4b97fbcff (MD5)
Previous issue date: 2009-03-27 / Objectives: To compare by digital subtraction radiography (SR), matched to clinical evaluation, bone response to single-tooth treated (TS) and non-treated (NTS) surface implants on immediate (IM) and conventional (CO) loading protocols.
Material and methods: 12 patients (8 underwent IM protocol and 4 underwent CO protocol) received 24 implants. Each subject received 2 implants (one with TS and the other NTS) homologously and bilaterally positioned in maxillae (lateral incisor, canine or premolar regions) or mandible (molar area). Standardized radiographies of each implant were taken on the day after implant placement (baseline image) and after 3, 6 and 12 months (follow-up images). SR was used for crestal bone loss (CBL) and peri-implant bone density (PIBD) measurements. The placement torque and resonance frequency (at 0, 6 and 12 months) were also measured for matching radiographic data.
Results: T-test revealed no statistically significant difference in CBL between TS and NTS implants, while TS implants presented higher PIBD in the mid-implant region at 3-months recall (p = 0.04). For IM protocol, the Mann-Whitney test revealed higher CBL at 6-months follow-up (p = 0.03), greater PIBD at 12-months recall (p = 0.06; p = 0.07) and increasing PIBD through time. There was a positive correlation between primary stability and PIBD at 12-months recall (r = 0.58; p = 0.005).
Conclusions: TS and NTS implants presented similar performances with regard to CBL and PIBD. IM and CO protocols were similarly successful. Primary stability was an important element in reaching greater PIBD after 1-year loading period / Objetivos: O objetivo desse estudo foi comparar através da subtração radiográfica digital (SRD), associada à avaliação clínica, a resposta óssea a implante unitário de superfície tratada (ST) e a implante de superfície não tratada (SNT) utilizando protocolos de carga imediata (CI) e convencional (CON).
Material e métodos: 12 pacientes (8 pelo protocolo de CI e 4 pelo protocolo de CON) receberam um total de 24 implantes. Cada indivíduo recebeu dois implantes, um de ST e outro de SNT, em posições homólogas bilaterais na maxila (regiões de incisivos laterais, caninos ou pré-molares) ou na mandíbula (área de molares). Imagens radiográficas padronizadas de cada implante foram obtidas no dia seguinte após procedimento cirúrgico de instalação (imagem de referência) e em 3, 6 e 12 meses seguintes (imagens de controle). As imagens foram submetidas à SRD para avaliação da perda de crista óssea alveolar (PCO) e obtenção da densidade óssea peri-implantar (DOPI). Além das radiografias padronizadas, o torque de inserção e a freqüência de ressonância dos implantes (em 0, 6 e 12 meses) foram medidos com finalidade de correlacioná-los à avaliação radiográfica.
Resultados: O teste T revelou ausência de diferença estatisticamente significativa entre implantes de ST e SNT em relação a PCO, enquanto o grupo de ST apresentou maior DOPI apenas na região de terço médio no controle de 3 meses (p = 0,04). Para o grupo submetido ao protocolo de CI, o teste de Mann-Whitney demonstrou maior PCO no controle de 6 meses (p = 0,03), maior DOPI no controle de 12 meses (p = 0,06; p = 0,07) e DOPI crescente ao longo do tempo. Houve uma correlação positiva entre a estabilidade primária e a DOPI no controle de 12 meses (r = 0,58; p = 0,005).
Conclusões: Os implantes de ST e SNT apresentaram comportamentos semelhantes quanto a PCO e DOPI. O protocolo de CI exibiu sucesso comparável ao do protocolo de CON. A estabilidade primária dos implantes foi um fator importante para atingir maior DOPI após 1 ano sob a ação de carga
|
Page generated in 0.0446 seconds