• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 224
  • 12
  • 12
  • 12
  • 12
  • 9
  • 5
  • 4
  • 3
  • 3
  • 3
  • 3
  • 1
  • 1
  • Tagged with
  • 234
  • 140
  • 139
  • 122
  • 100
  • 97
  • 52
  • 48
  • 36
  • 34
  • 28
  • 28
  • 27
  • 27
  • 24
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
61

Utilização do extrato de óleo insaponificável de abacte e soja na osseointegração. Avaliação biomecânca, radiográfica, histológica e histomorfométrica em ratos

Paula, Luiz Guilherme Freitas de [UNESP] 28 March 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:47Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-03-28Bitstream added on 2014-06-13T20:26:55Z : No. of bitstreams: 1 paula_lgf_me_arafo.pdf: 746134 bytes, checksum: 5963765673b2f4be8b648c4119483545 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Este estudo avaliou a influência da utilização do extrato de óleo insaponificável de abacate e soja na osseointegração de implantes. Foram utilizados implantes de titânio com 4 mm de comprimento por 2.2 mm de espessura, instalados nas tíbias de ratos. Os 30 ratos foram divididos randomicamente em três grupos: 1- instalação de implantes e administração de soro fisiológico; 2- administração do extrato de óleo insaponificável de abacate e soja 7 dias antes dos implantes; 3- instalação dos implantes e administração do extrato de óleo insaponificável de abacate e soja. O medicamento foi administrado por gavagem diariamente, durante 60 dias até o sacrifício. A avaliação se deu através de exames radiográficos (por densidade óssea/milímetro de alumínio), realizados no dia da instalação dos implantes e no dia do sacrifício; análise biomecânica; análise histomorfométrica de contato osso-implante e preenchimento ósseo entre as roscas dos implantes (regiões medulares e corticais ósseas); e análise histológica. O teste de Shapiro-Wilk foi aplicado para a verificação da normalidade dos dados, e o teste paramétrico ANOVA complementado pelo teste de Tukey foi utilizado para comparação dos dados. Todos os testes foram aplicados com nível de significância de 95%. Os resultados obtidos da análise radiográfica nas imagens iniciais, o grupo II apresentou menores valores de densidade tanto nas regiões de osso cortical como medular comparados aos grupos I e III. Entretanto, as razões de densidade radiográfica do osso nas imagens finais foram sem diferença estatística para todos os grupos. Na análise biomecânica não houve diferenças estatísticas entre os grupos. Na histologia descritiva e histometria, o grupo I apresentou menor contato osso-implante na área da cortical óssea em relação aos demais grupos... / This study evaluated the influence of the use of oil extract of avocado and soybean unsaponifiables on osseointegration of implants. Titanium implants used were 4 mm long by 2.2 mm thick, installed in the rat tibia. The 30 rats were randomly divided into three groups: 1 - implant placement and administration of saline, 2 - Administration of the extract oil of avocado and soybean unsaponifiable 7 days before the implants, 3 - implant placement and administration of the extract oil Avocado and soybean unsaponifiables. The drug was administered by gavage daily for 60 days until sacrifice.The evaluation was made by radiographic examination (for bone density / mm of aluminum), performed on the day of implant placement and the day of sacrifice, biomechanical, histomorphometric analysis of bone-implant contact and bone fill between the threads of the implants ( medullary and cortical bone regions), and histological analysis. The Shapiro-Wilk test was applied to verify the normality of the data, and parametric test ANOVA complemented by Tukey's test was used to compare the data. All tests were applied with a significance level of 95%. The results of radiographic images in the initial group II had lower density in the regions of cortical bone marrow as compared to groups I and III. However, the reasons for radiographic density of bone in the final images were no statistically significant difference for all groups. In biomechanical analysis no statistical differences between groups. Histologically descriptive and histometric analysis, group I showed lower bone-implant contact in the area of cortical bone in relation to other groups. The extract oil unsaponifiable of avocado and soybean had a positive influence on osseointegration of implants
62

Análise in vivo da modulação óssea em implantes de titânio com superfície em nanoescala / Analysis in vivo of bone modulation in titanium implants with nanoscale surface

Carvalho, Lais Morandini 20 November 2017 (has links)
Submitted by LAÍS MORANDINI CARVALHO null (lais_morandini@yahoo.com.br) on 2018-01-03T14:22:11Z No. of bitstreams: 1 Lais Morandini Carvalho.pdf: 3515290 bytes, checksum: b29a2f58afa414dd9e9f4df531340ca2 (MD5) / Approved for entry into archive by Silvana Alvarez null (silvana@ict.unesp.br) on 2018-01-04T18:53:50Z (GMT) No. of bitstreams: 1 Carvalho_lm_dr_sjc.pdf: 3515290 bytes, checksum: b29a2f58afa414dd9e9f4df531340ca2 (MD5) / Made available in DSpace on 2018-01-04T18:53:50Z (GMT). No. of bitstreams: 1 Carvalho_lm_dr_sjc.pdf: 3515290 bytes, checksum: b29a2f58afa414dd9e9f4df531340ca2 (MD5) Previous issue date: 2017-11-20 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Nas últimas décadas houve um aumento considerável na utilização dos implantes metálicos para aplicações na área da ortopedia e odontologia, por isso as pesquisas têm como foco estudar os mecanismos biológicos de interação osso-implante. A nanotopografia de superfície de implantes osseointegráveis apresenta efeito direto sobre a resposta biológica óssea. No entanto a maneira como afeta a osseointegração in vivo ainda não está totalmente elucidada. O objetivo neste estudo foi comparar in vivo a influência da superfície em nanoescala (nano) confeccionada em implantes de titânio comercialmente puro (Ticp), comparado-a a superfície lisa (controle) em modelo experimental de camundongos osterix-mcherry (Osx-mcherry), os quais expressam proteína fluorescente concomitante com a expressão do gene osterix (Osx). Os animais receberam implantes de superfície lisa no fêmur direito e com nanoescala no fêmur esquerdo. Após diferentes períodos de eutanásia baseados na metodologia empregada foram realizados nas peças e nas células os seguintes testes biológicos: microscopia eletrônica de varredura (MEV) para avaliação da adesão celular e da superfície do implante; histologia e nanotomografia (nanoCT) para observação e quantificação de osso neoformado na interface osso/implante; citometria de fluxo para quantificação de células marcadas pelo gene osterix; PCR em tempo real (qPCR) para avaliação da expressão gênica; coloração fosfatase ácida resistente ao tartarato (TRAP) para contagem de osteoclastos. Nossos resultados mostraram que a maioria dos genes estudados estavam superexpressos nas amostras com superfície em nanoescala sendo que alguns deles apresentaram diferenças estatísticas (Teste t, p < 0.05), tais como: Osx (osterix), Alp (fosfatase alcalina), Prx1(homeobox relacionado emparelhado -1), Dmp1 (Dolicol-fosfatase mannosiltransferase subunidade 1), Bsp (sialoproteína óssea) e Ocn (osteocalcina). Os testes estatísticos ANOVA two way seguido do Teste de Tukey quando necessário, foram utilizados para os demais experimentos e o nível de significância foi estabelecido em p < 0.05. Diferenças estatísticas foram encontradas para o nanoCT e histologia entre as superfícies e períodos avaliados e os melhores resultados foram observados para a nanoescala. A coloração TRAP também mostrou diferenças estatísticas entre as superfícies e períodos estudados, com a superfície lisa mostrando melhores resultados aos 3 dias e a nano aos 5 e 7 dias. Não houve diferença estatística para a citometria de fluxo, porém a superfície em nanoescala mostrou melhores resultados que a lisa em todos os períodos analisados. Concluímos que a superfície em nanoescala possui propriedades osteocondutivas e favorece os eventos biológicos que ocorrem na superfície do implante melhorando o processo de osseointegração.
63

Análise in vivo da modulação óssea em implantes de titânio com superfície em nanoescala /

Carvalho, Lais Morandini. January 2017 (has links)
Orientador: Luana Marotta Reis de Vasconcellos / Coorientador: Gustavo Mendonça / Banca: Daniela Baccelli Silveira Mendonça / Banca: Elisa Mattias Sartori / Banca: Yasmin Rodarte Carvalho / Banca: Renata Falchete do Prado / Resumo: Nas últimas décadas houve um aumento considerável na utilização dos implantes metálicos para aplicações na área da ortopedia e odontologia, por isso as pesquisas têm como foco estudar os mecanismos biológicos de interação osso-implante. A nanotopografia de superfície de implantes osseointegráveis apresenta efeito direto sobre a resposta biológica óssea. No entanto a maneira como afeta a osseointegração in vivo ainda não está totalmente elucidada. O objetivo neste estudo foi comparar in vivo a influência da superfície em nanoescala (nano) confeccionada em implantes de titânio comercialmente puro (Ticp), comparado-a a superfície lisa (controle) em modelo experimental de camundongos osterix-mcherry (Osx-mcherry), os quais expressam proteína fluorescente concomitante com a expressão do gene osterix (Osx). Os animais receberam implantes de superfície lisa no fêmur direito e com nanoescala no fêmur esquerdo. Após diferentes períodos de eutanásia baseados na metodologia empregada foram realizados nas peças e nas células os seguintes testes biológicos: microscopia eletrônica de varredura (MEV) para avaliação da adesão celular e da superfície do implante; histologia e nanotomografia (nanoCT) para observação e quantificação de osso neoformado na interface osso/implante; citometria de fluxo para quantificação de células marcadas pelo gene osterix; PCR em tempo real (qPCR) para avaliação da expressão gênica; coloração fosfatase ácida resistente ao tartarato (TRAP) para contagem de osteoc... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: In the last decades there has been a considerable increase in the use of metal implants for applications in the area of orthopedics and dentistry, so the researches are focused on studying the biological mechanisms of boneimplant interaction. Surface nanotopography of osseointegrated implants has a direct effect on the biological response of bone. However the way it affects osseointegration in vivo is not yet fully elucidated. The aim of this study was to compare the in vivo influence of the nanoscale surface (nano) made on implants of commercially pure titanium (Ticp) with the smooth surface (control), using an experimental model of osterix-mcherry mice (Osxmcherry), which express fluorescent protein concomitant with osterix gene expression (Osx). The animals received implants with smooth surface in the right femur and nanoscale in the left femur. After different periods of euthanasia based on the methodology used, biological tests were performed in the femur and cells: scanning electron microscopy (SEM) for evaluation of cell adhesion and implant surface; histology and nanotomography (NanoCT) for observation and quantification of neoformed bone at implant interface; flow cytometry for quantification of cells marked by the osterix gene; Realtime PCR (qRT-PCR) for gene expression evaluation; tartrate resistant acid phosphatase staining (TRAP) for osteoclast counts. Our results showed that most genes studied were overexpressed in the nanoscale surface and some of which presented statistical differences(t Test, p <0.05), such as: Osx (osterix), Alp (alkaline phosphatase), Prx1 (related paired homeobox), Dmp1 (Dolicol-phosphatase mannosyltransferase subunit 1), Bsp (bone sialoprotein) and Ocn (osteocalcin). The two-way ANOVA statistical test followed by the Tukey test when necessary were used for the other experiments and the level ...(Resumo completo, clicar acesso eletrônico abaixo) / Doutor
64

Estudo comparativo em coelho entre enxerto bovino e autógeno irradiados com laser infravermelho de comprimento de onda 780 m

Magalhães Junior, Edival Barreto de 20 December 2012 (has links)
Submitted by Hiolanda Rêgo (hiolandar@gmail.com) on 2013-11-12T18:47:10Z No. of bitstreams: 1 Tese_ODONTO_Edival Barreto de Magalhães Junior.pdf: 24814752 bytes, checksum: 9e66c47cd7fe4747372599f4870ed1ba (MD5) / Approved for entry into archive by Flávia Ferreira (flaviaccf@yahoo.com.br) on 2013-11-19T11:57:45Z (GMT) No. of bitstreams: 1 Tese_ODONTO_Edival Barreto de Magalhães Junior.pdf: 24814752 bytes, checksum: 9e66c47cd7fe4747372599f4870ed1ba (MD5) / Made available in DSpace on 2013-11-19T11:57:46Z (GMT). No. of bitstreams: 1 Tese_ODONTO_Edival Barreto de Magalhães Junior.pdf: 24814752 bytes, checksum: 9e66c47cd7fe4747372599f4870ed1ba (MD5) / O objetivo deste estudo foi avaliar e comparar pela histomorfometria o comportamento de enxerto ósseo em bloco bovino mineralizado (Orthogen®; BAUMER®) em fêmur de coelho fotobiomodulado com laser diodo infravermelho l780hm. Foram utilizados 24 animais divididos em oito grupos nos quais cada animal recebeu enxerto em bloco, autógeno e xenógeno. Nos grupos III, IV, VII e VIII, o enxerto foi irradiado com laser infravermelho (780nm, 70mW, CW) a cada 48 horas com uma dose de 16J/cm2 por sessão, ao longo de 7 sessões. Os animais dos grupos I, II, III e IV foram sacrificados após o período de nove semanas. Nos grupos V, VI, VII e VIII, após o período de incorporação dos enxertos, foi instalado um implante de titânio de 3.5 mm de diâmetro por 7 mm de comprimento em cada bloco. Os animais foram sacrificados oito semanas após a fixação dos implantes. A peça histológica obtida foi corada com azul de toluidina e fucsina básica. A avaliação através da microscopia óptica indicou que após nove semanas, os grupos irradiados apresentaram maior quantidade de osso neoformado quando comparados ao grupo controle. A histomorfometria demonstrou que o grupo xenógeno irradiado obteve 40,55±7,16% de osso neoformado e foi estatisticamente significante quando comparado ao não irradiado (10,69±2,11%). Na análise do Contato Osso-Implante (COI) para os grupos que receberam implantes não houve diferença estatisticamente significante entre o enxerto xenógeno irradiado e o não irradiado. O grupo VIII obteve um percentual de 65,27±9,66% enquanto que o grupo VI apresentou 58,93±8,6%. Concluiu-se que a fotobiomodulação realizada pelo laser infravermelho agiu positivamente sobre os enxertos xenógenos durante a incorporação óssea, pelo aumento da quantidade de novo osso formado, o que não ocorreu com o COI.
65

Ligas de TiNbZr com superfícies bioativas : caracterização topográfica e avaliação do contato ósseo in vivo /

Moretti, Lívia Alves Corrêa. January 2017 (has links)
Orientador: Elcio Marcantonio Junior / Resumo: O foco principal deste estudo centrou-se sobre as propriedades da superfície do titânio comercialmente puro, Ti6Al4V e novas ligas de TiNbZr, quando empregada técnica de modificação de superfície por anodização anódica com cálcio e fósforo. Foram avaliadas tanto a caracterização topográfica dos metais como sua relevância com interações com estruturas ósseas adjacentes. As técnicas de caracterização de superfície: rugosidade superficial, MEV, MFA e interferometria ótica foram utilizadas para determinar os padrões topográficos específicos para cada uma das amostras utilizada neste estudo e, para análise das interções biológicas, avaliou-se em conjunto a porcentagem de contato ósseo das novas superfícies funcionais in vivo, em coelhos. A anodização promoveu formação de uma multicamada de poros com incorporação de íons cálcio e fósforo nas superfícies do Ti cp e das ligas Ti6Al4V, Ti35Nb5Zr e Ti35Nb10Zr. A liga Ti35Nb10Zr foi considerada moderadamente rugosa (1.061µm ±0.179) e apresentou os melhores paramâmetros de rugosidade, o que pode ter influenciado em maior porcentagem de contato ósseo, quando comparadas aos demais grupos deste estudo. Comprovamos que as ligas Ti35Nb5Zr e Ti35Nb10Zr, em especial a liga Ti35Nb10Zr anodizada, apresentam boas propriedades biológias que permitirão que estes materiais possam ser empregados, em um futuro próximo, na confecção de novos sistemas de implantes. / The focused of this stydy was based on surface properties of commercially pure titanium, Ti6Al4V and new TiNbZr alloys with surface modification technique by anodic anodization with Ca and P. Topographic characterization of metals and biological interactions relevance were evaluated. Surface characterization techniques: surface roughnesses, SEM, AFM, optical interferometry were performed to determine specific topographic patterns for each samples used in this study and additionally, the percentage of bone contact of new functional surfaces was evaluated in vivo by histometry. Anodization technique promoted a multilayer pores with calcium and phosphorus incorporation on the surfaces: cp Ti and Ti6Al4V, Ti35Nb5Zr and Ti35Nb10Zr alloys. Ti35Nb10Zr alloy was considered with moderately rough (1.061µm ±0.179) and showed the best roughness parameters, may trigger suitable biological responses when compared to other groups of this study. It was concluded that Ti35Nb5Zr and Ti35Nb10Zr alloys, especially anodized Ti35Nb10Zr alloy, exhibit biocompatible properties that allow these materials can be used to make new implant systems in a short future. / Doutor
66

Estudo comparativo in vivo de implantes Ti-cp com superfícies comerciais e modificadas por laser sem e com depósito de sílica : análises biomecânica, topográfica e histomorfométrica /

Souza, Francisley Ávila. January 2010 (has links)
Resumo: Proposição: O objetivo deste estudo foi comparar o comportamento biológico e mecânico do tecido ósseo ao redor de implantes de superfícies comerciais modificada por condicionamento ácido (SA), e usinada (SU), com implantes de superfícies experimentais modificada por laser (SL), e modificada por laser com depósito de sílica (SS), empregando-se as análises biomecânica, topográfica e histométrica. Material e Métodos: Trinta coelhos receberam 120 implantes de 3,75x10mm em suas tíbias direita e esquerda, sendo dois implantes de cada superfície por tíbia. O implante localizado mais superior, instalado na metáfise tibial foi utilizado para o ensaio biomecânico, descrito no capítulo I; e o implante localizado abaixo deste, instalado na epífise tibial foi utilizado para o estudo histométrico, descrito no capítulo II. A morfologia das superfícies dos implantes foi analisada por microscopia eletrônica de varredura (MEV), e por espectroscopia de energia dispersiva de raios X (EDS) antes, e após 4 semanas de implantação e remoção por torque reverso. Medidas de rugosidade e secção transversal foram obtidas. Após períodos de 4, 8, e 12 semanas realizou-se o ensaio biomecânico, e após os animais sofreram eutanásia. As peças do implante localizado na epífise tibial foram levadas ao micrótomo para corte sem descalcificação. A análise histométrica foi realizada empregando-se microscopia óptica. Foi mensurada a extensão linear de contato entre osso e implante (ELCOI), e a área óssea (AO). Uma lâmina de cada superfície do período de 4 semanas foi metalizada para realização da análise do mapeamento elementar por MEV-EDS. Resultados: A caracterização topográfica mostrou diferenças entre as superfícies analisadas, e os valores de rugosidade média das SL e SS foram estatisticamente superiores (p<0,05) a SA. Na comparação estatística dos valores obtidos... (resumo completo, clicar acesso eletrônico abaixo) / Abstract: Purpose: The aim of this study was to compare the biologic and mechanical behavior of bone tissue around implants with commercially available surfaces, modified by acid etching (SA), and machined surfaces (SU), with the experimental surfaces modified by laser (SL), and modified by laser with silica deposition (SS), using biomechanical, topographic and histometric analyses. Materials and Methods: Thirty rabbits received 120 implants measuring 3,75x10mm in their right and left tibias, being two implants of each type of surface per tibia. The implant located in the uppermost position, inserted in the tibial metaphysis, was used for the biomechanical test, described in Chapter I; and the implant located below this, inserted in the tibial epiphysis, was used for the histometric study, described in Chapter II. The morphology of the implant surfaces was analyzed by scanning electron microscopy (SEM) and by energy dispersive X-ray spectrometry (EDS) before and after 4 weeks of implantation and removal by reverse torque. Mean roughness and cross-sectional measurements were obtained. After periods of 4, 8, and 12 weeks the biomechanical test was performed, and after this the animals were euthanized. The parts of the implant located in the tibial epiphysis were taken for cutting nondecalcified on a microtome. Histometric analysis was performed using an optical microscope. The bone interface contact (BIC), and the bone area (AO) were measured in percentages. A slide of each surface in the period of 4 weeks was metalized in order to analyze the element mapping by means of SEM-EDS. Results: The topographic characterization showed differences between the analyzed surfaces, and the mean roughness values of SL and SS were statistically higher (p<0,05) than those of SA. In the statistical comparison of the values obtained by the biomechanical test, it was... (Complete abstract click electronic access below) / Orientador: Celso Koogi Sonoda / Coorientador: Roberta Okamoto / Banca: Antônio Carlos Guastaldi / Banca: Renato Sussumu Nishioka / Banca: Sérgio Bruzadelli Macedo / Banca: Idelmo Rangel Garcia Júnior / Banca: Osvaldo Magro Filho / Doutor
67

Influência da nicotina na osseointegração de implantes instalados em tíbias de ratos: avaliação biomecânica, histológica, histométrica e imunoistoquímica / Influence of nicotine on osseointegration of implants installed in the tibia of rats: biomechanical, histological, histometric and immunohistochemical evaluation

Faleiros, Paula Lazilha [UNESP] 05 July 2016 (has links)
Submitted by PAULA LAZILHA FALEIROS null (paulal.faleiros@hotmail.com) on 2016-08-03T13:15:45Z No. of bitstreams: 1 TESE DE DOUTORADO - PAULA FINAL.pdf: 7373323 bytes, checksum: 4741d1f9d635d1e4879a2cd520afb7ae (MD5) / Rejected by Ana Paula Grisoto (grisotoana@reitoria.unesp.br), reason: Solicitamos que realize uma nova submissão seguindo a orientação abaixo: O arquivo submetido está sem a ficha catalográfica. A versão submetida por você é considerada a versão final da dissertação/tese, portanto não poderá ocorrer qualquer alteração em seu conteúdo após a aprovação. Corrija esta informação e realize uma nova submissão contendo o arquivo correto. Agradecemos a compreensão. on 2016-08-03T13:36:52Z (GMT) / Submitted by PAULA LAZILHA FALEIROS null (paulal.faleiros@hotmail.com) on 2016-08-03T13:55:04Z No. of bitstreams: 1 TESE DE DOUTORADO - PAULA FINAL.pdf: 7377120 bytes, checksum: c55964dddab287b8b096d337e07195bf (MD5) / Approved for entry into archive by Ana Paula Grisoto (grisotoana@reitoria.unesp.br) on 2016-08-03T18:08:55Z (GMT) No. of bitstreams: 1 faleiros_pl_dr_araca_par.pdf: 1921873 bytes, checksum: 138048a39be83d82924179cc13951f8c (MD5) / Made available in DSpace on 2016-08-03T18:08:55Z (GMT). No. of bitstreams: 1 faleiros_pl_dr_araca_par.pdf: 1921873 bytes, checksum: 138048a39be83d82924179cc13951f8c (MD5) Previous issue date: 2016-07-05 / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Objetivo: Avaliar do ponto de vista biomecânico, histomorfométrico, histoquímico e através de marcadores imunoistoquímicos a influência da terapia com laser em baixa intensidade (LLLT) na osseointegração de implantes instalados em tíbias de ratos modificados ou não sistemicamente pela nicotina. Materiais e métodos: Um total de 120 ratos (Wistar) foi distribuído em dois grandes grupos experimentais (n = 60) submetidos a duas aplicações diárias de solução salina (Veh) ou nicotina (Nic). Após 30 dias, implantes de titânio (2.2 mm x 4 mm) foram instalados na metáfise proximal de ambas as tíbias de todos os animais. Grupos experimentais de diferentes tratamentos locais do alvéolo cirúrgico previamente a instalação do implante (n = 30) foram criados no momento da cirurgia: Veh - nenhum tratamento; Veh/LLLT - irradiação do alvéolo cirúrgico com laser em baixa intensidade; Nic - nenhum tratamento; Nic/LLLT - irradiação do alvéolo cirúrgico com laser em baixa intensidade. O laser utilizado foi o Thera Lase (InGaAlP 660 nm, modo de aplicação contínuo, em contato com a área, 35 mW, 0,14 J, 4,9 J/cm2, por 4 segundos). Dez animais de cada grupo foram eutanasiados aos 15, 30 e 60 dias pós-operatórios. As tíbias direitas foram submetidas à análise de torque reverso e posteriormente processadas para confecção de cortes histológicos descalcificados, corados por hematoxilina e eosina, vermelho picrosirius ou submetidos a reações imunoistoquímicas com os anticorpos primários policlonais: HIF-1 α, VEGF, BMP-2, RUNX-2, OCN, ALP, RANKL, OPG e TRAP. A partir das tíbias esquerdas foram preparados cortes histológicos calcificados para análise das porcentagens de contato osso-implante (BIC) e área óssea (BA), dentro dos limites das roscas do implante. A análise foi realizada através da microscopia de luz polarizada para análise histoquímica e da microscopia óptica de campo claro para a análise histológica, histométrica e imunoistoquímicas. As imunomarcações foram submetidas à análise qualitativa para os anticorpos HIF-1 α, VEGF, BMP-2, OCN, ALP, RANKL e OPG e análise quantitativa para os anticorpos RUNX-2 e TRAP. Os dados quantitativos foram analisados estatisticamente (p≤0,05). Resultados: A nicotina atrasou a produção de elementos da matriz óssea, diminuiu o padrão de imunomarcação de HIF-1α, VEGF, BMP-2, OCN, ALP e OPG, aumentou o padrão de imunomarcação de RANKL e aumentou a quantidade de células imunorreativas a RUNX-2 e TRAP, diminuindo a BA, embora não tenha sido capaz de influenciar o torque de remoção e o BIC. O laser aumentou o padrão de imunomarcação de HIF-1α, VEGF, BMP-2, OCN e ALP, aumentou a quantidade de células imunorreativas a RUNX-2 e TRAP, aumentou a BA, mas também não foi capaz de influenciar o torque de remoção e o BIC. Adicionalmente, o laser influenciou positivamente a BA e o torque de remoção dos implantes, aumentou a angiogênese e a diferenciação osteoblástica, promovendo a formação óssea, biomineralização e maturação óssea peri-implantar nos animais modificados sistemicamente pela nicotina. Conclusão: A LLLT é capaz de promover o processo de reparo ósseo peri-implantar em condições normais e compensar os efeitos negativos da nicotina na osseointegração. / Objective: To evaluate, from biomechanical, histomorphometric, histochemical stand point and through of immunohistochemical markers, the influence of low level laser therapy (LLLT) on the osseointegration of implants placed in the tibias of nicotine systemically modified (or not) rats. Materials and methods: A total of 120 rats (Wistar) was assigned into two major experimental groups (n = 60) underwent two-daily-applications of saline (Veh) or nicotine (Nic). After thirty days, titanium implants (2.2 mm x 4 mm) were placed in the proximal metaphysis of both tibiae from all animals. Experimental groups of different surgical alveolus local treatments prior to implant placement (n = 30) were created at the moment of the surgery: Veh - no local treatment; Veh/LLLT - irradiation of surgical alveoli with low level laser; Nic - no local treatment; Nic/LLLT - irradiation of surgical alveoli with low level laser. The laser used was Thera Lase® (InGaAIP 660 nm, in continuous mode, in contact with the area, 35 mW, 0.14 J, 4.9 J/cm2 , for 4 seconds). Ten animals from each group were euthanized at 15, 30 and 60 days postoperative. The right tibiae were submitted to reverse-torque analysis and, then processing in order to prepare decalcified histological sections, stained either by hematoxylin and eosin or picrosirius red or subjected to immunohistochemical reactions with the primary polyclonal antibodies: HIF-1 α, VEGF, BMP-2, RUNX-2, OCN, ALP, RANKL, OPG and TRAP. From left tibias were prepared undecalcified histological sections to evaluate the percentages of bone-to-implant contact (BIC) and bone area (BA) within the limits of the implant threads. The histochemical analysis was performed by a polarized light microscopy and the histological, histometric and immunohistochemical analysis were performed by a bright field optical microscopy. The HIF- 1α, VEGF, BMP-2, OCN, ALP, RANKL and OPG immunostaining were submitted to qualitative analysis and the RUNX-2 and TRAP immunostaining were submitted to quantitative analysis. Quantitative data were analyzed statistically (p≤0.05). Results: The nicotine delayed the production of bone matrix components, decreased the imunolabeling pattern of HIF-1α, VEGF, BMP-2, OCN, ALP and OPG, increased the imunolabeling pattern of RANKL, increased the amount of RUNX-2 and TRAP-immunoreactive cells, reduced the BA, but did not influence the BIC and the force required to break the osseointegration. The laser increased the imunolabeling pattern of HIF-1α, VEGF, BMP-2, OCN and ALP, increased the amount of RUNX-2 and TRAP-immunoreactive cells, increased the BA, but also was not be able to influence the BIC and the force required to break the osseointegration. In addition, the laser positively influenced the BA and the implant removal torque, increased the angiogenesis and osteoblast differentiation, promoted bone formation, biomineralization and peri-implant bone maturation in the nicotine systemically modified rats. Conclusions: LLLT is able to promote the peri-implant bone repair process in normal conditions and is able to compensate the negative effects of nicotine on osseointegration. / FAPESP: 2013/11863-0
68

Efeito na osseointegração de um novo método de nanotexturização de superfície de implantes através de anodização / Effect on osseointegration of a new method of nano texturing implant surface by anodization

Villaça-Carvalho, Maria Fernanda Lima [UNESP] 29 January 2016 (has links)
Submitted by MARIA FERNANDA LIMA Villaça-Carvalho (mfervillaca@hotmail.com) on 2016-03-29T02:07:44Z No. of bitstreams: 1 TESE MARIA FERNANDA merged.pdf: 3220002 bytes, checksum: cc48d2a3494318d6c9c1f4af8c06c37f (MD5) / Approved for entry into archive by Ana Paula Grisoto (grisotoana@reitoria.unesp.br) on 2016-03-29T17:32:30Z (GMT) No. of bitstreams: 1 villacacarvalho_mfl_dr_sjc.pdf: 3220002 bytes, checksum: cc48d2a3494318d6c9c1f4af8c06c37f (MD5) / Made available in DSpace on 2016-03-29T17:32:30Z (GMT). No. of bitstreams: 1 villacacarvalho_mfl_dr_sjc.pdf: 3220002 bytes, checksum: cc48d2a3494318d6c9c1f4af8c06c37f (MD5) Previous issue date: 2016-01-29 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A Implantodontia é uma das áreas da Odontologia que mais tem evoluído nas últimas décadas. Diversos estudos são desenvolvidos na intenção de otimizar o processo de osseointegração utilizando a nanotopografia na superfície dos implantes. Atualmente o processo de anodização da superfície vem se destacando entre estas técnicas. Desta forma, o objetivo nesta pesquisa foi obter nano rugosidades e fase de anatase em implantes odontológicos de Titânio, buscando a otimização da osseointegração. Sessenta implantes foram caracterizados quanto à morfologia, por meio de microscopia de força atômica (AFM) e Microscopia Eletrônica de Varredura (MEV); quanto à composição química, por análise por detector de espectrometria por espalhamento de energia (EDS) e Espectroscopia Raman; e por fim, quanto ao potencial de corrosão, pela análise de impedância eletroquímica (EIE). A osteogênese, in vivo, foi comparada por Radiografia periapical (RP), Microtomografia Computadorizada (μTC) e teste de remoção por torque reverso; e, a análise in vitro, foi realizada por teste de citotoxicidade por MTT [(brometo de 3-4,5-dimetiltiazol-2-il)-2,5-difeniltetrazoliol]. Os implantes foram divididos em: G1 (controle); Grupo 2 (jateado); Grupo 3 (anodizado-experimental). Cada coelho recebeu um implante de cada grupo nas tíbias direita e esquerda, e cinco coelhos, foram eutanasiados 2 e 6 semanas após a cirurgia. Os implantes da tíbia direita foram submetidos à RP e à μTC; e os da tíbia esquerda, ao teste de torque reverso e análise de citotoxicidade por MTT. AFM e MEV comprovaram a presença de nano rugosidades na superfície em G3; análises de EDS e Espectroscopia Raman, demonstraram aumento da camada do filme de TiO2 e a obtenção de anatase em G3. Na RP, nenhum implante apresentou halo radiolúcido. Na μTC, G3 foi sempre superior aos demais grupos nos parâmetros observados: BV, BV/TV, Tb.Th. No teste de torque reverso, houve necessidade de maior força de remoção dos implantes anodizados. No teste por MTT, os implantes experimentais foram atóxicos células. Conclui-se que a anodização utilizada neste estudo afetou positivamente a composição química e estrutural do filme de TiO2, melhorando suas características biológicas na osseointegração. / The Implantology is one of the areas of dentistry that has most evolved in recent decades. Many studies have been developed with the intention of optimizing the osseointegration process using nanotopography on the surface of the implants. Currently the surface of the anodizing process has stood out among these techniques. Thus, the aim of this research was to obtain nano roughness and anatase phase in dental Titanium implants, seeking for the optimization of the osseointegration. Sixty implants were characterized for morphology by atomic force microscopy (AFM) and Scanning Electron Microscopy (SEM); in chemical composition, by mass spectrometry detector energy scattering (EDS) and Raman spectroscopy; and finally, as the potential for corrosion, the electrochemical impedance analysis (EIS). Osteogenesis in vivo was compared by Periapical Radiography (PR), Computed Microtomography (μTC), removal reverse torque test; and in vitro analysis, it was performed by MTT cytotoxicity assay [(bromide 3-4,5-dimethylthiazol-2-yl) -2,5-difeniltetrazoliol]. The implants were divided into G1 (control); Group 2 (sandblasted); Group 3 (anodized-experimental). Each rabbit received an implant of each group in the right and left tibias and five rabbits were euthanized 2 and 6 weeks after surgery. The implants of the right tibia underwent PR and μTC; and the left tibia, the reverse torque test and MTT cytotoxicity assay. AFM and SEM confirmed the presence of nano roughness on the surface in G3; EDS analysis and Raman spectroscopy showed increased TiO2 film layer and obtainment of anatase G3. In PR, no implant presented radiolucent halo. In μTC, G3 has always been higher than the other groups in the observed parameters: BV, BV / TV, Tb.Th. In the reverse torque test, It was required greater removal force of anodized implants. In the MTT test, the experimental implants were nontoxic to cells. It was conclude that the anodizing process used in this study positively affected the chemical and structural composition of TiO2 film, improving their biological characteristics at osseointegration.
69

Avaliação de substitutos ósseos em defeitos peri-implantares criados em coelhos

Santos, Pâmela Letícia dos [UNESP] 28 March 2013 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:07Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-03-28Bitstream added on 2014-06-13T20:41:19Z : No. of bitstreams: 1 santos_pl_dr_araca.pdf: 1518173 bytes, checksum: 780aa208fda4e1610407dd0ff2ab5be9 (MD5) / Objetivo: Avaliar a efetividade dos substitutos ósseos, matriz de osso bovino mineralizada – (Bio-Oss®) e matriz de osso bovino mineralizada com adição de 10% de colágeno suíno – (Bio-Oss® Collagen), no preenchimento de defeitos peri-implantares criados em tíbia de coelhos, por meio das análises biomecânica, histológica e imunoistoquímica para a expressão das proteínas OC, Runx 2, OPG, RANK-L e TRAP . Material e Métodos: Trinta coelhos receberam 1 ostectomia em cada tíbia por meio de trefina de 6.1 mm de diâmetro. Em seguida, foram utilizadas as fresa lança e helicoidais no preparo de leitos receptores com 3,0mm e 1 implante de 4,1 mm/8,5 mm foi instalado. Os defeitos ósseos peri-implantares foram preenchidos de acordo com os seguintes grupos: I- coágulo sanguíneo (CO); II- Bio-Oss® (BI); e III- Bio-Oss® Collagen (BC). Dez animais por período foram eutanasiados aos 15, 30 e 60 dias pós-operatórios, para as análises biomecânica, histológica e imunoistoquímica. Resultados: Na análise biomecânica, pode-se observar que o grupo BC apresentou melhor resposta, estatisticamente significante, quando comparado ao CO, no período de 30 dias. Os resultados imunoistoquímicos mostraram na comparação entre os 3 grupos a expressão da OC foi diferente estatisticamente nos períodos de 15 e 60 dias entre os grupos CO e BC; e CO e BI, respectivamente, observando maior expressão para o grupo dos biomateriais aos 15 dias. A expressão de Runx2 foi menor estatisticamente para o grupo BI quando comparado aos demais grupos, no período de 15 dias. Aos 60 dias, a expressão de OPG no grupo BI se apresentou estatisticamente maior que o grupo CO. Nos períodos de 15 e 60 dias, pode-se observar maior expressão de RANK-L... / Objective: To evaluate the effectiveness of bone substitutes in peri-implant defects created in tibia of rabbits which were filled either by blood clot, deproteinized bovine bone mineral (Bio-Oss® / Geistlich) and bovine bone mineral with the addition of 10% collagen porcine origin (Bio-Oss Collagen® / Geistlich), through biomechanics, histology and immunohistochemical analysis of OC, Runx 2, OPG, RANK-L and TRAP proteins. Material and methods: Thirty rabbits received one osteotomy in each tibia using trefine of 6.1 mm in diameter. Subsequently, a spear and helical drills, 2.0 mm, 2.0/3.0 pilot and 3.0 mm were used and 1 implant 4.1 mm/8.5 mm was installed. Bone defects were filled according to the following groups: I-blood clot (CO); II-deproteinized bovine bone mineral (Bio-Oss®) (BI); III-bovine bone mineral with addition of 10% collagen porcine origin (Bio-Oss Collagen®) (BC). Ten animals per period were euthanized at 15, 30 and 60 postoperative days, subsequently biomechanical analysis were performed. Routine histologic processing for histological and immunohistochemistry analysis were also performed. Results: In biomechanics analysis, comparing the different groups for each period can be observed that within 30 days, the BC group showed better biological response statistically proven compared to CO. In immunohistochemistry analysis, the OC expression was statistically significant at 15 and 60 days between CO and BC groups, and between CO and BI groups, respectively, with largest expression for the group of biomaterials. In these same analysed periods, an increased expression of RANK-L can be observed on BI group compared to CO group. OPG expression was statistically significant only iat 60 postoperative days for BI group... (Complete abstract click electronic access below)
70

Regeneração óssea de defeitos circunferenciais criados cirurgicamente ao redor de implantes submersos. Estudo experimental em cães

Rossi, Fabio [UNESP] 06 September 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:32:40Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-09-06Bitstream added on 2014-06-13T19:22:09Z : No. of bitstreams: 1 rossi_f_dr_araca.pdf: 2781899 bytes, checksum: c7a4e989b92a1d7cf3f24753f22ce3c4 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Objetivo: descrever o processo de reparo em defeitos marginais ao redor de implantes submersos 1mm abaixo ou acima da crista óssea. Estudo experimental em cães. Material e Métodos: Em 12 cães labradores, todos os pré-molares inferiores e primeiros molares foram extraídos bilateralmente. Três meses após as extrações, foi realizada a incisão sobre o rebordo e o descolamento dos retalhos de espessura total do lado direito da mandíbula. Foram preparados dois sítios cirúrgicos para instalação de implantes, com a região marginal alargada em 5mm de diâmetro para obtenção de um gap de 0,5 mm na região mesial (defeito pequeno) e um gap de 1,25 mm na região distal (defeito grande). Os parafusos de cobertura foram colocados aos implantes e os retalhos suturados para permitir um processo de cicatrização totalmente submerso. Posteriormente, foram realizados os mesmos procedimentos experimentais no lado esquerdo da mandíbula. O momento da realização dessas cirurgias e as eutanásias foram planejados de forma a se obter biópsias com 5, 10, 20, 30 dias de pósoperatórios. Após a eutanásia, os cortes histológicos foram processados laboratorialmente para análise histomorfométrica. Resultados: Aos 30 dias pós-operatório, os defeitos ósseos apresentaram-se parcialmente preenchidos por osso neoformado em todos os espécimes. A formação óssea ocorreu originando-se a partir da base do defeito e das paredes laterais. Um maior volume de osso neoformado foi observado nos defeitos grandes quando comparado aos pequenos. A maior parte de osso neoformado nos defeitos grandes formou-se entre o décimo e vigésimo dias de pósoperatórios. Entretanto, o contorno do osso neoformado localizou-se a uma distância similar da superfície do implante (aproximadamente 0,4 mm) em ambos os tipos de defeitos, no... / Objective: to describe the healing of marginal defects below or above one millimeter of dimension around submerged implants in a dog model. Material and Methods: In 12 Labrador dogs, all mandibular premolars and first molars were extracted bilaterally. After 3 months of healing, full-thickness flaps were elevated in the edentulous region of the right side of the mandible. Two recipient sites were prepared and the marginal 5 mm were widened to such an extent to obtain, after implant installation, a marginal gap of 0.5 mm at the mesial site (small defect) and of 1.25 mm at the distal site (large defect). Titanium healing caps were affixed to the implants and the flaps were sutured allowing a fully-submerged healing. The experimental procedures were subsequently performed in the left side of the mandible. The timing of the experiments and sacrifices were planned in such a way to obtain biopsies representing the healing after 5, 10, 20, 30 days. Ground sections were prepared and histomorphometrically analyzed. Results: The filling of the defect with newly formed bone was incomplete after one month of healing in all specimens. Bone formation occurred from the base and the lateral walls of the defects. A larger volume of new bone was formed in the large compared to the small defects. Most of the new bone at the large defect was formed between the 10 and the 20-day period of healing. After one month of healing, the outline of the newly formed bone was, however, located at a similar distance from the implant surface (about 0.4 mm) at both defect types. Only minor newly formed bone in contact with the implant, starting from the base of the defects, was seen at the large defects (about 0.8 mm) while a larger amount was detected at the small defects (about 2.2 mm). Conclusion: Marginal defects around titanium... (Complete abstract click electronic access below)

Page generated in 0.0568 seconds