Estudo estrutural e ultraestrutural da interface osso-implante em ovelhasAzambuja, Fabiano Goulart January 2009 (has links)
Made available in DSpace on 2011-12-27T14:14:33Z (GMT). No. of bitstreams: 2
000422969-0.pdf: 4980923 bytes, checksum: 2690ee5096ce9b097a8aa97b37d89ecf (MD5)
license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / Studies have showed that roughness surfaces in titanium implants can modulate bones responses. The objective of present study is evaluate the bone implant contact between two types of dentistry implants with differents treatments of surface, Titamax EX Cone Morse® sandblasted/acid-etched and a Titamax EX Cone Morse® with a new proposal surface called nanosurface, in a sheep model, during 30 and 60 days. Two female sheeps received 10 implants each (n=20), five sandblasted/acid etched implants and five with the new surface implant. Implants were inserted in tibia an ulna. After the euthanization, in 30 and 60 days, the specimens were processed and a scanning electron microscopy was used to evaluate the bone contact implant of these two types of dentistry implants in a different time. The software Image J Plus® was used to determine the bone contact implants and SPSS® for statistical analyses. The histomorphology showed bone formation between implants crests in both groups, in 30 days. However, there was a lose in bone contact implant in the nanosurface group, in 60 days. The sandblasted/etched group mantained its measures. These differences were statistically significant. More studies are necessary to improve this new kind of surface a long time to become accceptable to clinical use and bennefit the patients / O objetivo desta pesquisa foi avaliar a ultraestrutura da superfície do implante através da microscopia eletrônica de varredura e a resposta histológica da interface osso-implante através da histomorfometria da osseointegração de duas superfícies de implantes (Titamax EX Cone Morse® jateado + ataque ácido e Titamax EX Cone Morse® desenvolvida com uma nova proposta de tratamento de superfície, ainda não comercializada, intitulada nanosuperfície) em modelo animal, avaliados após um período de 30 e 60 dias. Foram utilizadas duas ovelhas adultas da espécie Ovis aries. As ovelhas foram divididas em dois grupos: uma ovelha pertencente ao grupo 1, com morte prevista após 30 dias da instalação dos implantes e uma ovelha pertencente ao grupo 2, com morte após 60 dias. Cada animal forneceu 10 amostras, sendo 05 amostras compostas por implantes dentários com superfície tratada com jato + ataque ácido e 05 amostras compostas por implantes dentários com superfície tratada com nanopartículas. As amostras foram processadas e avaliadas em microscópio eletrônico de varredura em diferentes magnitudes para avaliar os resultados do contato entre o osso e a superfície dos implantes nos períodos propostos. O programa Image J Plus® foi usado para a avaliação desse contato e o SPSS® para a análise estatística. A histomorfometria mostrou a formação óssea sobre a superfície dos implantes em ambas as amostras no grupo 1, ou seja, no período de 30 dias. Entretanto, apesar da formação óssea também ocorrer sobre a superfície dos implantes em ambas as amostras do grupo 2, ou seja, no período de 60 dias, observou-se uma perda do contato osso-implante na amostra de nanosuperficie ao longo do período da pesquisa. Para se tornar mais aceitável o uso clínico em benefício aos pacientes dos implantes Titamax EX Cone Morse® nanosuperficie, outros estudos se fazem necessários para sugerir melhorias no tratamento de superfície dos implantes e para avaliação por períodos maiores de tempo.
|
92 |
Análise da diferenciação de células da medula óssea humana cultivadas sobre diferentes superfícies de titânioBeltrão, Rodrigo Gomes January 2009 (has links)
Made available in DSpace on 2011-12-27T14:14:37Z (GMT). No. of bitstreams: 2
000417773-0.pdf: 1138982 bytes, checksum: 03423e2cddaa5a43349be69c0853e615 (MD5)
license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / Given that the majority of osseointegrated implants undergo some type of surface conditioning in order to improve osseoitegration and that in vitro differentiation of mesenchymal cells into osteoblasts is a mastered process that has been used for evaluating a given biomaterial with regard to its osteinductive and osteoconductive capabilities, the present work aims to evaluate the adhesion, proliferation and differentiation of human bone marrow cells on titanium implant surfaces that have or have not been treated by discrete calcium phosphate deposition. Human bone marrow cells obtained from a single donor were cultured in media containing 12 titanium discs of one of the following: the Bonelike® (Biomet 3I, Brazil) with a surface treated by double acid etching; the Osseotite™ (Biomet 3I, USA) with similar surface treatment and the Nanotite™(Biomet 3I, USA). After 14 and 21 days of culture, real time PCR and SEM examinations were performed. From the results we concluded that implant surface roughness allows cell adhesion, differentiation and proliferation, the ALP synthesis is higher in Bonelike® and the presence of calcium phosphate nanoparticles on an implant surface leads to enhanced BGLAP synthesis and cell proliferation. / Os implantes osseointegrados, em sua maioria, possuem algum tipo de condicionamento da sua superfície que visa melhorar a osseointegração. O mecanismo de diferenciação celular in vitro de células mesenquimais em osteoblastos já é bastante conhecido e serve para avaliação das propriedades de osteoindução e osteocondução de biomateriais. O presente estudo tem por objetivo avaliar a adesão, proliferação e diferenciação das células da medula óssea humana em superfícies de implantes de titânio com e sem deposição discreta de fosfato de cálcio. As células foram obtidas a partir da medula óssea de um doador humano. Foram selecionados 12 discos de titânio do tipo Bonelike® (Biomet 3I, Brasil) com superfície tratada por duplo ataque ácido; Osseotite™ (Biomet 3I, USA) com superfície tratada por duplo ataque ácido e Nanotite™ (Biomet 3I, USA). Após 14 e 21 dias de cultura foi realizado PCR em tempo real para avaliação da diferenciação celular e microscopia eletrônica de varredura para avaliação da proliferação e adesão celular aos discos de titânio. Os resultados indicaram que a rugosidade da superfície dos discos de titânio possibilita a adesão, diferenciação e proliferação celular, que a síntese de ALP é maior na superfície Bonelike e que as partículas de fosfato de cálcio demonstraram maior grau de síntese de BGLAP e proliferação celular.
|
93 |
Desenvolvimento e caracterização de nanotubos de TiO2 em implantes de titânioBessauer, Luciano Herbstrith January 2011 (has links)
Made available in DSpace on 2013-08-07T18:54:54Z (GMT). No. of bitstreams: 1
000434834-Texto+Completo-0.pdf: 2467680 bytes, checksum: d94eca86dabe6ec28377349c07e8a880 (MD5)
Previous issue date: 2011 / The passive behavior of the titanium oxide layer formed is an important characteristic for the biomedical application. The interactions with the biological environment after the implantation of a prosthesis are directly linked, among others factors, with the physicist-chemical properties of the surface of the implanted material. Titanium surfaces that are chemical or electrochemical treated tend to develop specific layers with chemical composition and porosity that promote osseointegration. The goal of this work is to study anodization process, to develop the nanotubes growth in titanium substrate. Electrolytic solutions of 1M H3PO4 and 0. 2 % HF were used varying the applied voltage and the distance among the electrodes. After the process anodic the specimens were treated thermally in the temperatures of 500, 600, 700, 800 and 900°C. The formed films and treaties thermally were analyzed by scanning electronic microscopy (SEM), energy dispersive spectroscopy (EDS) and X-rays diffraction (DRX). The results nominated to the formation of nanotubes in the anodic treated titanium oxides films in every extension of the surface, in addition to uniformity of the oxide layer and regularity of the diameter of nanotubes the 0,171mm. The analyses of the chemical composition indicated the presence of match, derived of the terms of the experiment. The structure crystallographic verified was hexagonal, which corresponds to the titanium structure. / O comportamento passivante da camada formada de óxido de titânio é uma característica relevante para a aplicação biomédica. As interações com o meio biológico após a implantação de uma prótese estão diretamente ligadas, entre outros fatores, com as propriedades físico-químicas da superfície do material implantado. As superfícies de titânio que são tratadas química ou eletroquimicamente tendem a desenvolver camadas específicas com composição química e porosidade que promovem a osseointegração. O objetivo deste trabalho é estudar o processo de anodização para desenvolver o crescimento de nanotubos de TiO2 em substrato de titânio comercialmente puro. Foram utilizadas soluções eletrolíticas de 1M H3PO4 e 0,2 % de HF variando a tensão aplicada e alterando o distanciamento entre os eletrodos. Após o processo anódico as espécimes foram tratadas termicamente nas temperaturas de 500, 600, 700, 800 e 900°C. Os film es formados e tratados termicamente foram analisados por microscopia eletrônica de varredura (MEV), espectroscopia por energia dispersiva (EDS) e difratometria de raios X (DRX). Os resultados indicaram a formação de nanotubos nos filmes de óxidos de titânio tratados anodicamente em toda extensão da superfície, além de boa uniformidade da camada de óxido e regularidade do diâmetro dos nanotubos de 171nm. As análises da composição química indicaram a presença de fósforo, oriundos das condições do experimento. A estrutura cristalográfica verificada foi hexagonal, a qual corresponde à estrutura do titânio.
|
94 |
Influência do método de osteotomia para preparação do leito na reparação óssea ao redor de implantes de titânio: comparação histológica entre instrumento rotatório e ultrassom cirúrgico piezoelétrico / Piezosurgery influence in bone healing around titanium dental implants: histological study in ratsMarcelo Sirolli Ferreira 19 February 2014 (has links)
O objetivo deste estudo foi avaliar histomorfometricamente a influência da piezocirurgia (PZ) sobre a reparação óssea ao redor de implantes de titânio. Foram utilizados 15 ratos machos Wistar, com aproximadamente 300g, nos quais em uma das patas o leito para instalação de um implante de titânio foi realizado com um motor rotatório convencional (Grupo Controle) e na outra com ultrassom cirúrgico piezoelétrico (Grupo Piezo). Após 30 dias, os animais foram sacrificados para obtenção do material para análise histológica. Foram avaliados os seguintes parâmetros histomorfométricos (em porcentagem), separadamente, para a região cortical e medular: a proporção de tecido mineralizado (PTM) na região adjacente ao implante (500m adjacentes); área de tecido mineralizado (AO) dentro dos limites das roscas do implante; e a extensão de tecido ósseo em contato direto (CD) com a superfície do implante. Os resultados deste estudo mostraram que não foram observadas diferenças para CD na região medular (p>0,05) e para PTM na região cortical (p>0,05). Por outro lado, um maior preenchimento das roscas foi observado quando utilizou-se a PZ tanto na região cortical (71,50 + 6,91 e 78,28 + 4,38; média + dp para os grupos Controle e Piezo; respectivamente p<0,05) quanto na região medular (9,62 + 4,06 e 19,94 + 14,18; média + dp para os grupos Controle e Piezo; respectivamente p<0,05). Resultados semelhantes foram observados para o parâmetro PTM na região medular (9,35 + 5,54 e 18,72 + 13,21; média + dp para os grupos Controle e Piezo; respectivamente p<0,05). Já a técnica convencional foi superior à PZ em relação a CD na região cortical (80,42 + 10,88 e 70,25 + 16,93; média + dp para os grupos Controle e Piezo; respectivamente p<0,05). Dentro dos limites do presente estudo, pode-se concluir que a piezocirurgia apresenta-se como uma alternativa viável no preparo de leito para instalação de implantes de titânio. / The aim of this study was to investigate the influence of two techniques of dental implant site preparation on bone healing around titanium dental implants. Fifteen male Wistar rats (+ 300g) were used in the study. In each rat tibiae was randomly assigned to receive the implant site preparation with a conventional drilling technique (Control) or with piezoelectric device (Piezo). After thirty days the animals were sacrificed and then the following histomorphometric parameters were evaluated (in percentage) separately to cortical and cancellous regions: Proportion of mineralized tissue (PMT) adjacent to implant threads (500um adjacent); bone area within the threads (BA); and bone-implant contact (BIC). The results demonstrated that there were no differences between the two groups for cancellous BIC (p>0.05) and cortical PTM (p>0.05). Meanwhile, a higher percentage of BA was observed in PIEZO group in the cortical (71,50 + 6,91 and 78,28 + 4,38; mean + stdev for groups Control and Piezo; respectively p<0.05) and cancellous regions (9,62 + 4,06 and 19,94 + 14,18; mean + stdev for groups Control and Piezo; respectively p<0.05). The piezosurgery also showed higher PTM values in the cancellous zone (9,35 + 5,54 and 18,72 + 13,21; mean + stdev for groups Control and Piezo; respectively p<0.05). However, Control presented better results for BIC in cortical region (80,42 + 10,88 and 70,25 + 16,93; mean + stdev for groups CTRL and PIEZO; respectively p<0.05). Within the limits of the present study, it can be concluded that piezosurgery is a feasible alternative in implant site preparation.
|
95 |
Tratamento de maxilas atroficas por meio de fixações zigomaticas : analise retrospectiva de 03 anos / Treatment of atrophic maxilla through zygomatic implants : retrospective analysis of 03 yearsRodriguez Chessa, Jaime Giuseppe 15 August 2018 (has links)
Orientador: Renato Mazzonetto / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-15T01:14:41Z (GMT). No. of bitstreams: 1
RodriguezChessa_JaimeGiuseppe_D.pdf: 2629539 bytes, checksum: 9e5185fe3e354d64d0557af2bfec5348 (MD5)
Previous issue date: 2009 / Resumo: A utilização de fixações zigomáticas e implantes convencionais para reabilitação de maxilas atróficas constitui uma alternativa recente e vem sendo amplamente descrito na literatura científica. Essas fixações foram desenvolvidas inicialmente para reabilitar pacientes que apresentavam seqüelas devido à ressecção de tumores sendo, atualmente, utilizados também como terapia para pacientes com reabsorção de osso alveolar em região posterior. O objetivo deste estudo foi avaliar retrospectivamente as fixações zigomáticas realizadas na área de Cirurgia Buco- Maxilo-Facial da Faculdade de Odontologia de Piracicaba da Universidade Estadual de Campinas (FOP-UNICAMP) e da área de Implantologia da Faculdade de Odontologia da Universidade de Guarulhos (FO-UnG) no período de Junho de 2006 a Julho de 2009. Para a realização deste estudo foram avaliados 29 pacientes submetidos à instalação de fixações zigomáticas. O tempo médio de proservação foi de 20 meses. Os dados obtidos nos prontuários clínicos foram transcritos para uma ficha de coleta de dados especificamente desenvolvida para esta pesquisa e transferidos periodicamente para serem analisados. Desse total, 18(62%) pacientes eram do gênero feminino e 11(38%) do gênero masculino. Das 67 fixações zigomáticas e 70 implantes convencionais instalados nos pacientes, 10 pacientes foram submetidos a carga imediata (34,48%) e 19 pacientes a carga tardia (65,51%) podendo se observar um índice de perda de 7,46% para os casos de carga imediata e 13,43% para os casos de carga tardia. Em relação a motivação para a instalação das fixações zigomáticas, o principal fator foi a queixa funcional, presente em 22 pacientes (75,86%), a queixa estética para 2 pacientes (6,9%) e a queixa funcional-estética em 5 pacientes (17,24%). A indicação principal foram os casos de reabsorção alveolar severa em 21 casos (72,41%), seguido pelos insucessos na reconstrução com enxerto ósseos intraorais e extraorais com 4 (13,79%),e 1 caso (3,45%), respectivamente. A reabilitação mais utilizada foi acomposta por duas fixações zigomáticas associadas a quatro implantes convencionais (44,82% dos casos), seguido pelo uso de 4 implantes zigomáticos (17,24%) e 2 fixações zigomáticos associadas a 2 implantes convencionais (13,79%). Em relação às complicações a principal foi a perda da osseointegração (40%), seguido por mucosite (20%) e a dor persistente (15%), sinusite (15%) assim como a exteriorização das fixações (10%). Quanto à perda das fixações zigomáticos, dos 67 implantes inicialmente colocados, 14 foram perdidos perfazendo uma taxa de insucesso de 20,90%. Foi realizada uma avaliação por meio de uma escala visual analógica (EVA) obtendo-se um nível de satisfação aceitável, a cirurgia foi considerada como pouco traumatizante e com melhora significativa da função e estética. / Abstract: The use of zygomatic implants and conventional implants for rehabilitation of atrophic jaws is a recent alternative and has been widely described in scientific literature. These fixtures were initially developed to rehabilitate patients that showed sequelae after tumors resectionts. There also used as a therapy for patients with resorption of the alveolar bone in the posterior region. The aim of this study was to evaluate retrospectively the zygomatic implants performed in the Division of Oral and Maxillo-Facial Surgery, Piracicaba Dental School, Campinas State University (FOP-UNICAMP) and the division Implantology, Dental School, University of Guarulhos (FO-UnG) between June 2006 to July 2009. 29 patients where evaluated for this study subjected to the installation of zygomatic implants. The mean proservation was 20 months. Data from clinical records were stored in a form of data collection specifically designed for this research and transferred periodically to be analyzed. From this total, 18 (62%) patients were female and 11 (38%) were male. Of the 67 zygomatic implants and 70 conventional implants installed in patients, 10 patients underwent immediate loading (34.48%) and 19 patients a late charge (65.51%) can be observed a loss rate of 7.46% for cases of immediate loading and 13.43% for cases of late charge. Regarding the motivation for the installation of zygomatic implants, the main factor was the functional complaint, present in 22 patients (75.86%), the complaint aesthetics for 2 patients (6.9%) and functional-aesthetic complaint in 5 patients (17.24%). The main indication was the case of severe alveolar resorption in 21 cases (72.41%), followed by failures in reconstruction with intraoral bone graft and extraoral with 4 (13.79%), and 1 case (3.45%) respectively. The most rehabilitation technique consist of two zygomatic implants associated with four conventional implants (44.82% of cases), followed by the use of 4 zygomatic implants (17.24%) and 2 zygomatic fixations associated with 2 conventional implants (13, 79%). Regarding the main complication was the lossof osseointegration (40%), followed by mucositis (20%) and persistent pain (15%), sinusitis (15%) as well as the manifestation of fixations (10%). Regarding the loss of the zygomatic fixations, of the 67 implants originally placed 14 were lost resulting in a failure rate of 20.90%. An evaluation was performed by a visual analogue scale (VAS) and obtained an acceptable level of satisfaction, surgery was considered as low level of trauma and significant improvement in function and aesthetics. / Doutorado / Cirurgia e Traumatologia Buco-Maxilo-Faciais / Doutor em Clínica Odontológica
|
96 |
Efeito da desmineralização das superfícies de contato na resistência à tração de enxertos ósseos autógenos em tíbia de coelhos. Analise mecânica e à microscopia eletrônica de varredura / Effect of the demineralization of the contacting surfaces in the tensile strength of autogenous bone grafts in rabbits tibiae. Mechanical and scanning electron microscopy analysisMarcus Gustavo Silva Rodrigues 23 March 2009 (has links)
Vinte e nove coelhos machos (Oryctolagus cuniculus) tiveram fragmentos ósseos corticais de 8mm de diâmetro removidos com trefina da metáfise proximal tibial que foram transplantados para uma área adjacente após a realização de um dos seguintes tratamentos: G-EDTA (desmineralização com EDTA pH neutro a 24% na forma de gel por 3 minutos das superfícies ósseas de contato); G-EDTA-P (o mesmo tratamento de G-EDTA e perfuração do leito receptor); G-P (perfuração do leito receptor) e G-C (nenhum tratamento adicional ao transplante). Noventa dias após as cirurgias, os animais foram eutanasiados para obtenção de blocos ósseos contendo os enxertos e preparo de corpos de prova para ensaio mecânico de determinação da resistência à tração e módulo de elasticidade. Os valores encontrados para resistência à tração foram: G-C = 2.0861.200 MPa; G-EDTA = 2.0330.976 MPa; G-EDTA-P = 1.9770.795 MPa e G-P = 1.8260.800 MPa. Entretanto, não houve diferença estatisticamente significante entre os grupos (p=0.819). Os valores médios do módulo de elasticidade foram: G-C = 38.8022.72 MPa; G-EDTA-P = 26.2414.17 MPa; G-EDTA = 25.119.89 MPa e G-P = 17.517.94 MPa, sendo identificada diferença estatística apenas entre o G-C e os demais. Concluiu-se que a desmineralização por EDTA das superfícies ósseas de contato em enxertos autógenos em bloco do tipo onlay não interfere na resistência à tração da interface independentemente da perfuração do leito receptor e que tanto a desmineralização como a perfuração aumentam a deformação dos corpos de prova sugerindo um melhor comportamento elástico nesses grupos. / Cortical bone fragments of 8mm of diameter were removed with trephine burr from the proximal tibial metaphysis of twenty nine male rabbits (Oryctolagus cuniculus) and transplanted to an adjacent area after one of the following treatments: G-EDTA (demineralization of the contacting bone surfaces with EDTA pH 24% during 3 minutes); G-EDTA-P (the same treatment of G-EDTA and perforation of the receiving host bed); G-P (perforation of the receiving host bed) and G-C (no additional treatment to the transplant). Ninety days post-operatively, the animals were euthanized in order to attain bone blocks with the grafts. The specimens were prepared to mechanical assay for tensile strength and Young modulus. The values found for tensile strenght were: G-C = 2.086±1.200 MPa; G-EDTA = 2.033±0.976 MPa; G-EDTA-P = 1.977±0.795 MPa and G-P = 1.826±0.800 MPa. These differences, therefore, were not statically significant (p=0.819). The Young modulus average values for the specimens were: G-C = 38.80±22.72 MPa; G-EDTA-P = 26.24±14.17 MPa; G-EDTA = 25.11±9.89 MPa and G-P = 17.51±7.94 MPa. There were statistically significant differences only between the G-C and the other groups. The results showed that EDTA demineralization of the contacting bone surfaces in onlay autogenous bone grafts does not interfere in the tensile strenght at the interface independently of the perforation of the host bed. On the other hand, demineralization as well as perforation increased the deformation of the specimens suggesting a better elastic behavior for these groups.
|
97 |
Superfícies de titânio modificadas por plasma: avaliação in vitro em cultura de células osteoblásticas / Titanium surfaces modified by plasma: in vitro evaluation in osteoblastic cell culturesEmanuela Prado Ferraz 31 August 2012 (has links)
As pesquisas na área da implantologia têm buscado desenvolver superfícies que acelerem o processo de osseointegração adjacente ao implante, permitindo a reabilitação funcional e estética precoce. Modificações da topografia e composição química têm sido propostas com o objetivo de modular as funções celulares na interface do tecido ósseo com o implante e, em última análise, aumentar o contato osso-implante. A deposição iônica por plasma é uma modalidade de tratamento utilizada em implantes ortopédicos. Na odontologia, estudos têm avaliado o efeito das diferentes técnicas de nitretação de superfícies de titânio (Ti) sobre eventos iniciais da osseointegração, como a adesão celular, mas não sobre eventos tardios. O presente estudo avaliou o efeito de superfícies de Ti modificadas por deposição iônica por plasma, pelas técnicas de nitretação por cátodo oco, por 1 e 3 h, e nitretação planar, nas expressões do fenótipo e gênica de osteoblastos derivados de osso alveolar de humanos e de calvária de ratos. Foram realizadas análises de morfologia, adesão e espraiamento celular, síntese e atividade de fosfatase alcalina (ALP), mineralização da matriz extracelular e expressão de genes marcadores do fenótipo osteoblástico. A adesão celular e a atividade de ALP, foram maiores nas superfícies de Ti tratadas comparadas à superfície sem tratamento (controle), enquanto a proliferação celular e a produção de matriz mineralizada não apresentaram diferenças estatisticamente significante entre os grupos. Ainda, as superfícies de Ti tratadas aumentaram a expressão gênica de ALP e diminuíram a de osteocalcina (OC) quando comparadas à superfície controle. Os resultados sugerem que a deposição iônica por plasma pelas técnicas de nitretação avaliadas modifica as características físico-químicas da superfície de Ti e promove atraso e aumento da diferenciação osteoblástica quando comparada à superfície de Ti não tratada. / A current goal in implantology research has been the development of titanium surfaces to enhance the process of osseointegration, allowing functional and aesthetic rehabilitation. Modifications on topography and chemical composition have been proposed in order to regulate cell functions of the osteoblasts in contact with the implant surface and ultimately increase the bone-to-implant contact. Plasma ionic deposition is a treatment usually employed in orthopedic implants and in dentistry some studies have shown that different nitriding techniques of titanium (Ti) surfaces may affect the initial events of osseointegration, such as cell adhesion, without evaluating the late ones. This study evaluated the effect of Ti surfaces modified by plasma nitriding combined with hollow cathode, during 1 and 3 h, and planar nitriding, on the phenotype and gene expression of osteoblasts derived from human alveolar bone and newborn rat calvaria. Cell morphology, adhesion and spreading, alkaline phosphatase (ALP) activity and synthesis, extracellular matrix mineralization and gene expression of bone markers were performed. The cell adhesion and ALP activity were higher on treated Ti surfaces compared with untreated (control) ones, while cell proliferation and extracellular matrix mineralization were not affected by the treatments. Also, compared with control Ti surface, the treated ones increased the gene expression of ALP and reduced osteocalcin (OC). The results suggest that the plasma ionic deposition by nitriding technique modifies the physicochemical features of the Ti surface and promotes a delay and a enhancement of the osteoblastic differentiation compared with untreated Ti surface.
|
98 |
Análise das propriedades físico-químicas e mecânicas de arcabouço poroso composto de PLGA, cerâmica bifásica e sinvastatina de liberação lenta para engenharia de tecido ósseoEncarnação, Isis Carvalho January 2016 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2016. / Made available in DSpace on 2016-09-20T04:15:50Z (GMT). No. of bitstreams: 1
340518.pdf: 22676667 bytes, checksum: 2b7347137b3b7d4a46fe8010f688abc8 (MD5)
Previous issue date: 2016 / Este estudo avaliou, in vitro, a liberação de sinvastatina em um arcabouço poroso inteligente , elaborado para engenharia de tecido ósseo, composto de PLGA e cerâmica bifásica, além das propriedades físico-químicas e mecânicas deste arcabouço. Foram obtidas amostras com 30 e 70% de porosidade sem sinvastatina e com 2, 5 e 8% de sinvastatina pela técnica de evaporação do solvente e lixiviação de partículas de sacarose. A degradação do arcabouço e a liberação de sinvastatina a partir destes arcabouços foi avaliada em meio contendo PBS e PBS com 30% de etanol. Os arcabouços foram analisados por microscopia eletrônica de varredura e microtomografia de Raios-X para caracterização morfológica 2D e 3D de sua porosidade, avaliação da interconectividade dos poros e permeabilidade de fluidos com auxílio dos softwares ImageJ, Imago e C3DE. O comportamento mecânico do arcabouço foi avaliado pelo teste de resistência à compressão e, sua caracterização química, foi determinada por meio de ensaio de calorimetria exploratória diferencial (DSC) e por espectroscopia de Raios-X por dispersão em energia. Como resultado, observou-se uma liberação lenta e prolongada de sinvastatina a partir do arcabouço. Em PBS, a liberação seguiu o modelo de Korsmeyer de cinética por meio do qual se observou um predomínio de transporte Caso II para amostras com 30% de porosidade e um comportamento anômalo das amostras com 70% de porosidade. Em PBS com 30% de etanol, a liberação de sinvastatina seguiu o modelo de Peppas & Sahlin de cinética. Neste, pode-se observar que os processos difusionais prevaleceram sobre os processos de relaxação das cadeias poliméricas para a liberação de sinvastatina, ocorrendo de maneira mais intensa nas amostras com 70% de porosidade. Os arcabouços apresentaram tanto poros esféricos quanto em formato de cristais de sacarose que resultaram em uma porosidade heterogênea, com predomínio de poros abertos, permitindo sua interconectividade. A interconectividade dos poros e a permeabilidade do arcabouço foi maior nas amostras em que o arcabouço possuía 70% de porosidade. A incorporação de sinvastatina ao arcabouço e o aumento de sua porosidade não influenciaram significativamente as propriedades mecânicas estudadas. Pode-se concluir que o arcabouço estudado apresentou uma liberação lenta, gradual e prolongada de sinvastatina, com características físico-químicas e mecânicas satisfatórias, sendo promissor para a regeneração óssea.<br> / Abstract : The aim of this study was to evaluate, in vitro, the simvastatin release of a porous "smart" scaffold composed by PLGA and biphasic ceramics and developed for bone tissue engineering. The physicochemical and mechanical properties of this scaffold were also evaluated. Samples with 30 and 70% porosity were obtained without simvastatin and with 2, 5 and 8% of simvastatin through the solvent evaporation technique and leaching sucrose particles. Scaffold degradation and simvastatin release were evaluated in PBS and in PBS with 30% ethanol media. Scaffolds were analyzed by scanning electron microscopy and microtomography for 2D and 3D morphological characterization of the porosity, interconnectivity and permeability of the fluids with ImageJ, Imago and C3DE softwares. The characterization was evaluated for compressive strength and chemical characterization by differential scanning calorimetry (DSC) and X-Ray spectroscopy by energy dispersion. Slow and prolonged release of simvastatin was observed from the scaffold. In PBS medium, the release followed the Korsmeyer s model of kinetics where there was predominance of transport Case II for the 30% porosity group and anomalous behavior in the group with 70% porosity. In PBS with 30% ethanol medium, the release followed the Peppas & Sahlin kinetics model where the diffusional processes prevail on the relaxation processes of polymer chains for the release of simvastatin, and this process was more intense the group with 70% porosity. The release was also influenced by the slow degradation of the scaffolds due to strong chemical interaction between simvastatin and the polymer observed by DSC. The scaffolds presented spherical pores and sucrose-crystal format pores that resulted in a heterogeneous porosity, with a predominance of open pores, ensuring interconnectivity. The highest interconnectivity of the pores and permeability were observed in the scaffolds with 70% porosity. The addition of simvastatin to the scaffolds and the increase of the porosity did not influence the mechanical properties studied. The scaffolds presented a slow, gradual and prolonged release of simvastatin, with satisfactory physicochemical and mechanical properties and may be promising for bone regeneration.
|
99 |
Avaliação dos tecidos peri-implantares : estudos clínicos /Nícoli, Lélis Gustavo. January 2018 (has links)
Orientador: Elcio Marcantonio Junior / Resumo: O objetivo do presente estudo foi investigar a ocorrência das doenças peri-implantares e a influência de possíveis fatores de risco utilizando duas abordagens metodológicas diferentes. Inicialmente realizou-se um estudo retrospectivo para avaliar a sobrevivência e o sucesso de implantes com superfície tratada com ataque ácido após 8 a 10 anos de função. Quarenta e quatro pacientes e 183 implantes foram incluídos. Dados demográficos, sistêmicos e comportamentais foram obtidos seguidos da avaliação clínica periodontal, peri-implantar e radiográfica realizados em uma única sessão. Nesse estudo relatou-se, nos 183 implantes avaliados, um índice de sobrevivência e sucesso de 97,3% e 84,7%, respectivamente. Dos implantes sobreviventes, 51% apresentavam mucosite e 11% peri-implantite. Posteriormente investigou-se, em um estudo prospectivo, a incidência de mucosite e perda óssea peri-implantar após 1 ano em função. Foram incluídos 56 pacientes totalizando 180 implantes. O exame clínico periodontal e peri-implantar seguido de radiografias periapicais padronizadas foi realizado 15 dias após a instalação das próteses e após 3, 6 e 12 meses de função. Com essa abordagem, observou-se uma incidência de 44,8% de mucosite peri-implantar, porém nenhum caso de peri-implantite foi observado nos 180 implantes avaliados. Implantes com conexão hexagono interno apresentaram incidência de mucosite significativamente maior após 1 ano de acompanhamento. Ademais, uma média de perda óssea peri-implantar... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The purpose of this investigation was to assess the incidence of peri-implant diseases and how they can be associated to possible risk factors. Two different approaches were addressed. Through a retrospective study, survival and success rates of implants with acid-etched-treated surface were initially evaluated in 44 patients, with 183 implants, in function for 8 to 10 years. Analysis included demographic, systemic and behavioral data, followed by one-session radiographic, periodontal and peri-implant clinical evaluations. This first study yielded survival and success rates of 97.3% and 84.7%, respectively, for the 183 investigated implants. Among the surviving implants, 51% were affected by mucosite and 11%, by peri-implantitis. A second study was also carried out to prospectively investigate mucosite incidence as well as peri-implantar bone loss in 180 implants, placed in 56 patients, after 1 year of function, which were assessed by clinical periodontal and peri-implant examinations, followed by standardized peri-apical radiographs, carried out 15 days after installation of the prosthesis, and at 3, 6 and 12 months of function. This observation revealed a 44.8% rate of peri-implant mucosite; however, no case of peri-implantitis was found. Implants with an intern-hexagon platform were significantly more affected by mucositis after one year of observation. In addition, a mean peri-implant bone-loss of 0.35 ± 1.89 mm was detected, however none of the patient or implant-related... (Complete abstract click electronic access below) / Doutor
|
100 |
Avaliação da osteointegração em implantes da liga de Tii7,5Mo com tratamento de superfície por anodização /Tupinambá, Rogerio Amaral. January 2019 (has links)
Orientador: Ana Paula Risifni Alves Claro / Coorientador: Ana Lúcia do Amaral Escada / Banca: Durval Rodrigues Júnior / Banca: Cristiane Aparecida Assis Claro / Banca: Ronaldo Spezia Nunes / Resumo: O objetivo deste estudo in vivo foi avaliar as propriedades de resposta óssea da liga de Ti7,5Mo usinada em minimplantes com tratamento de superfície por anodização e compara-la, com sua versão não tratada e com a liga de Ti-CP em sua apresentação comercial, tratada por jateamento e ataque ácido, em relação às suas propriedades de osteointegração. Os minimplantes do Grupo tratado de Ti7,5Mo foram anodizados em eletrólito de NH4F por 24h e em seguida calcinados a 450ºC por 1h. As amostras foram divididas em três Grupos, Ti-CP com tratamento de superfície por jateamento seguido de ataque ácido (n=5), Ti7,5Mo usinadas (n=5) e Ti7,5Mo anodizado para crescimento de nanotubos de TiO2 (n=6). Para caracterização das amostras foram realizados a espectroscopia Raman, difração de raios X, perfilometria ótica e microscopia eletrônica de varredura. As análises histomorfométricas para determinação do BIC (bone to implant contact) e do BAFO (bone area fraction occupancy) foram realizadas após implantação das amostras de cada Grupo na tíbia de ratos Wistar sacrificados após 4 semanas. A análise estatística por meio do teste de ANOVA de 1 fator demonstrou haver diferença estatística significante apenas entre os Grupos para o BIC; o teste Tukey para avaliação do BIC demonstrou haver diferença estatística significante somente entre o Grupo Ti7,5Mo anodizado em relação ao Grupo Ti-CP em apresentação comercial; não foram detectadas diferenças estatísticas significantes para o BAFO entre os Grupos... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The objective of this in vivo study was to evaluate the bone response of the Ti7,5Mo alloy machined in minimplants with surface treatment by anodization and compare it, with its untreated version and with the Ti-CP alloy in its commercial presentation, gritblasted and acid-etched. The Ti7,5Mo minimplants of the treated group were anodised in a NH4F electrolyte for 24h and then calcinated at 450ºC for 1h. The samples were divided into three groups, Ti-CP with surface treatment by blasting followed by acid-etched (n=5), Ti7, 5Mo machined (n=5) and Ti7, 5Mo anodized for growth of TiO2 nanotubes (n=6). To characterize the samples, Raman spectroscopy, X-ray diffraction, optical perfilometry and scanning electron microscopy (SEM) were performed. The Histomorphometric analysis for determination of the BIC (bone to implant contact) and BAFO (bone area fraction occupancy) were performed after the tibia implantation of the samples of each group in Wistar rats sacrificed after 4 weeks. The statistical analysis using the 1-factor ANOVA test showed statistically significant difference only for BIC amongst groups, Turkey test showed statistically significant difference for the evaluation of BIC only between the group Ti7, 5Mo anodized in relation to the Ti-CP group in commercial presentation, Turkey test did not detect significant statistical difference for BAFO among the groups. Pearson test did not detect direct correlation between BIC and BAFO values. The Ti7,5Mo samples with anodised s... (Complete abstract click electronic access below) / Doutor
|