Spelling suggestions: "subject:"percepção dde fall"" "subject:"percepção dee fall""
61 |
Percepção da fala e qualidade de vida em usuários de adaptação abertaTatiana Manfrini Garcia 26 February 2014 (has links)
Indivíduos com perda auditiva descendente referem dificuldade de percepção da fala no ruído levando a um afastamento social e podendo afetar de forma determinante a qualidade de vida. O objetivo deste estudo foi analisar a relação entre o desempenho do indivíduo com perda auditiva em altas frequências na percepção da fala por meio do Hearing In Noise Test (HINT) e a qualidade de vida utilizando o World Health Organization Quality of Life (WHOQOL-bref) antes e após a adaptação do AASI de adaptação aberta. Foram avaliados 30 indivíduos com diagnóstico de perda auditiva sensorioneural com configuração em rampa, restrita as altas frequências (a partir de 2k Hz), compatível com adaptação AASI de adaptação aberta, utilizando o questionário de qualidade de vida WHOQOL-bref, antes da adaptação dos AASI e 90 dias após uso efetivo dos mesmos e o teste HINT que foi realizado em três situações divididas em duas fases: fase 1, no momento da adaptação nas situações sem AASI (situação A) e com AASI (situação B), e fase 2, com AASI, 90 dias após a adaptação dos mesmos (situação C). Os resultados mostraram através da análise de variância e teste de Tukey comparando as três situações do HINT no silêncio e ruído frente que houve melhora no HINT após a adaptação do AASI. A comparação dos resultados do WHOQOL-bref pré e pós-adaptação feita por meio do teste t-pareado indicou melhora na qualidade de vida após a adaptação do AASI. A relação entre percepção da fala e qualidade de vida antes da adaptação do AASI feita por meio do coeficiente de correlação de Pearson indicou relação significante apenas para o reconhecimento de fala no ruído e o domínio das relações sociais após a adaptação do AASI. Frente aos resultados obtidos podemos concluir que o AASI de adaptação aberta favoreceu a percepção da fala de indivíduos com perda auditiva em altas frequências e a adaptação do mesmo promoveu melhora na qualidade de vida do indivíduo, e quanto melhor o reconhecimento de fala no ruído melhor a qualidade de vida, principalmente nas relações sociais. / Subjects with descendant hearing loss reported difficulty in speech perception within noisy environments, leading to social seclusion that can decisively affect the quality of life. The aim of this study was to analyze the relationship between the performance of the individual with hearing loss in the high frequencies of speech perception by the Hearing In Noise Test (HINT) and the quality of life using the World Health Organization Quality of Life (WHOQOL-bref) before and after the fitting of open fit hearing aids (HA). 30 Subjects were evaluated with a diagnosis of sensoryneural hearing loss with ramp configuration, restricted high frequencies (from 2 kHz), compatible with the open fit hearing aid adaptation and were assessed using the questionnaire of quality of life WHOQOL-bref before the adaptation of HA and 90 days after the effective usage and HINT test that was conducted in three situations divided into two phases : phase 1, at the time of adaptation in situations without HA (situation A) and with HA (situation B) , and phase 2 , with HA , 90 days after the adaptation of the same (situation C) . Results by the analysis of the variance and Tukey test comparing the three situations recongnized that the HINT in quiet and noise showed an improvement after the hearing aid fitting. Comparing the results of the pre WHOQOL-bref and post - adaptation made by the paired t-test indicated an improvement in quality of life after the hearing aid fitting. The relationship between speech perception and quality of life before the fitting of hearing aids made by the Pearson correlation coefficient showed a significant relationship only for speech recognition in a noisy environment and the domain of social relations after the hearing aid fitting. Given our results we conclude that the open fit hearing aids favored the speech perception of individuals with hearing loss in high frequencies, the adaption improves the quality of life of the individual, and how much better speech recognition in a noisy environment relates to a better quality of life, especially concerning social interaction.
|
62 |
Reconhecimento de monossílabos em idosos: análise do nível de apresentação da fala / Monosyllabic words recognition in elderly: analysis of the speech presentation levelBruna Antonini Santana 26 February 2016 (has links)
A perda auditiva no idoso acarreta em dificuldade na percepção da fala. O teste comumente utilizado na logoaudiometria é a pesquisa do índice de reconhecimento de fala máximo (IR-Max) em uma única intensidade de apresentação da fala. Entretanto, o procedimento mais adequado seria a realização do teste em diversas intensidades, visto que o índice de acerto depende da intensidade da fala no momento do teste e está relacionado com o grau e configuração da perda auditiva. A imprecisão na obtenção do IR-Max poderá gerar uma hipótese diagnóstica errônea e o insucesso no processo de intervenção na perda auditiva. Objetivo: Verificar a interferência do nível de apresentação da fala, no teste de reconhecimento de fala, em idosos com perda auditiva sensorioneural com diferentes configurações audiométricas. Métodos: Participaram 64 idosos, 120 orelhas (61 do gênero feminino e 59 do gênero masculino), idade entre 60 e 88 anos, divididos em grupos: G1- composto por 23 orelhas com configuração horizontal, G2- 55 orelhas com configuração descendente, G3- 42 orelhas com configuração abrupta. Os critérios de inclusão foram: perda auditiva sensorioneural de grau leve a severo, não usuário de aparelho de amplificação sonora individual (AASI), ou com tempo de uso inferior a dois meses, e ausência de alterações cognitivas. Foram realizados os seguintes procedimentos: pesquisas do limiar de reconhecimento de fala (LRF), do índice de reconhecimento de fala (IRF) em diversas intensidades e do nível de máximo conforto (MCL) e desconforto (UCL) para a fala. Para tal, foram utilizadas listas com 11 monossílabos, para diminuir a duração do teste. A análise estatística foi composta pelo teste Análise de Variância (ANOVA) e teste de Tukey. Resultados: A configuração descendente foi a de maior ocorrência. Indivíduos com configuração horizontal apresentaram índice médio de acerto mais elevado de reconhecimento de fala. Ao considerar o total avaliado, 27,27% dos indivíduos com configuração horizontal revelaram o IR-Max no MCL, assim como 38,18% com configuração descendente e 26,19% com configuração abrupta. O IR-Max foi encontrado no UCL, em 40,90% dos indivíduos com configuração horizontal, 45,45% com configuração descendente e 28,20% com configuração abrupta. Respectivamente, o maior e o menor índice médio de acerto foram encontrados em: G1- 30 e 40 dBNS; G2- 50 e 10 dBNS; G3- 45 e 10 dBNS. Não há uma única intensidade de fala a ser utilizada em todos os tipos de configurações audiométricas, entretanto, os níveis de sensação que identificaram os maiores índices médios de acerto foram: G1- 20 a 30 dBNS, G2- 20 a 50 dBNS; G3- 45 dBNS. O MCL e o UCL-5 dB para a fala não foram eficazes para determinar o IR-Max. Conclusões: O nível de apresentação teve influência no desempenho no reconhecimento de fala para monossílabos em idosos com perda auditiva sensorioneural em todas as configurações audiométricas. A perda auditiva de grau moderado e a configuração audiométrica descendente foram mais frequentes nessa população, seguida da abrupta e horizontal. / Hearing loss in elderly causes difficulty in speech perception. The test commonly used in speech audiometry is the search for the maximum speech recognition score (PB-Max) in a single presentation intensity of speech. However, the most adequate procedure would be the test at multiple intensities considering that the correct level depends on the intensity of the speech at the moment of the test and is related to the degree and configuration of hearing loss. The imprecision in obtaining the PB-Max can produce an erroneous diagnostic hypothesis and failure in the intervention process in hearing loss. Purpose: To verify the interference of the level of speech presentation, through the speech recognition test, in elderly patients with sensorineural hearing loss with different audiometric configurations. Methods: Participants were 64 elderly, 120 ears (61 females and 59 males), ages ranging from 60 to 88, divided into three groups: G1- comprising 23 ears with flat configuration, G2- 55 ears with gradually sloping, G3- 42 ears with steeply sloping configuration. The criteria of inclusion of individuals were: sensorineural hearing loss from mild to severe degree, no hearing aid users, or period of use lower than two months, and absence of any cognitive impairment. The following procedures were performed: speech recognition threshold (SRT), word recognition scores at multiple intensities, most comfortable loudness level (MCL) and uncomfortable loudness level (UCL) using speech stimuli. For the procedure above, lists of 11 monosyllabic words were presented, in order for the test duration to be reduced. Statistical analysis was made by the test Analysis of Variance (ANOVA) and Tukey\'s test. Results: The gradually sloping configuration was the most common. Subjects with flat configuration showed higher correct mean level in speech recognition. Considering the total ears assessed, 27.27% of subjects with flat configuration revealed the PB-max in MCL, as well as, 38.18% with gradually sloping and 26.19% with steeply sloping configuration. The PB-max was found in the UCL, in 40.90% of the subjects with a flat configuration, 45.45% with gradually sloping configuration and 28.20% with steeply sloping configuration. Respectively, the highest and the lowest correct mean indexes were found: G1- 30 and 40 dB SL; G2- 50 and 10 dB SL; G3- 45 and 10 dB SL. There is not a single speech intensity to be used in all types of audiometric configurations, however, the sensation levels that identified the correct mean levels were found: G1 - 20-30 dB SL, G2 - 20-50 dB SL; G3 - 45 dB SL. The MCL and UCL-5 dB using speech stimuli, were not effective to determine the PB-Max. Conclusion: The presentation level influenced the performance in speech recognition for monosyllables in elderly patients with sensorineural hearing loss in all audiometric configurations. Moderate hearing loss and gradually sloping configuration were more frequent in this population, followed by steeply sloping and flat configuration.
|
63 |
A percepção de fala no ruído em idosos: influência do grau e configuração da perda auditiva / The speech perception in noise in elderlies: influence of hearing loss degree and audiogram configurationIsabela Alves de Quadros 17 February 2017 (has links)
A avaliação para diagnóstico da perda auditiva em idosos é comumente realizada com o mesmo protocolo dos pacientes adultos, porém, essa população apresenta características audiológicas distintas, devido ao envelhecimento global do sistema auditivo periférico e central. A queixa principal da perda auditiva associada ao envelhecimento é a dificuldade de compreensão de fala, principalmente em ambientes com ruído competitivo. Desta forma, a avaliação audiológica convencional é fundamental, porém insuficiente para avaliar as queixas auditivas do idoso, uma vez que os testes utilizados não permitem uma avaliação da compreensão da fala em situações do dia-a-dia, incluindo as situações com ruído competitivo. Assim, a realização de testes que avaliam a percepção de fala no ruído é imprescindível na avaliação da percepção de fala nesta população. A literatura da área evidencia relação entre os limiares audiométricos e as habilidades de percepção da fala, mas os estudos desta relação na presença de ruído competitivo são escassos. Objetivo: investigar a influência da idade, do grau da perda auditiva e da configuração da curva audiométrica na percepção de fala na presença de ruído competitivo em idosos com perda auditiva. Materiais e métodos: Participaram 164 indivíduos (93 do gênero masculino e 71 do gênero feminino), idade entre 60 a 90 anos, divididos nos grupos: G1 126 indivíduos, 49 do gênero feminino e 77 do gênero masculino, com configuração abrupta; G2 - 38 indivíduos, 22 do gênero feminino e 16 do gênero masculino, com configuração descendente. Os critérios de inclusão foram: idade igual ou maior à 60 anos; perda auditiva sensorioneural bilateral simétrica; indivíduos não usuários de aparelho de Aparelho de Amplificação Sonora Individual (AASI); ausência de alterações cognitivas. Foi realizado o teste de percepção de fala por meio do Hearing Noise in Test (HINT), nas modalidades mono e binaural, com fone auricular. A análise estatística foi composta pela Regressão Linear Múltipla. Resultados: A configuração e o grau da perda auditiva de maior ocorrência foi, respectivamente, abrupta e moderado. Ao considerar a configuração, a média ISO e a idade como variáveis independentes, os valores de R² ajustado variaram, na modalidade binaural de 28% a 65%, e na modalidade monoaural de 42% a 65%. Quanto à configuração, grau da perda auditiva e idade, os valores de R² ajustado variaram, na modalidade binaural de 20% a 48%, e na modalidade monoaural de 37% a 58%. A diferença ocorreu quanto à idade, média ISO e grau da perda auditiva (p0,05) em todas as condições do HINT, exceto na condição de ruído à esquerda na modalidade binaural, na qual houve diferença apenas para média ISO. Os valores de da média ISO foram maiores em comparação à idade. Conclusão: A configuração audiométrica não influenciou o desempenho dos indivíduos idosos no HINT, no entanto, houve influência da idade e da perda auditiva (grau e média ISO). A perda auditiva apresentou maior influência na percepção de fala, tanto no silencio como no ruído e nas modalidades de escuta monoraural e binaural, em comparação à idade. / The evaluation of hearing loss in elderly is generally realized with the same patients adults protocol, however, the elderly population presents audiological characteristic different, because the overall aging of the central and peripheral auditory system. The main complaint of presbycusis is the difficulty to understand the speech, mainly in places with competitive noise. This way, the conventional evaluation audiological is fundamental, however not enough to evaluate the audiological complaint of elderly, because this tests do not measure the perception speech in day-to-day, including situation with competitive noise. To realize test that measure the speech perception in noise is indispensable in elderly population. The literature show relation between audiometric thresholds and speech perception abilities, but the investigations about this relation when there is competitive noise are scarce. Aim: To investigate the influence of age, hearing loss degree and audiogram configuration in speech perception in noise in elderly with hearing loss. Methods: 164 individuals (93 male and 71 female), age between 60 and 90 years old, divided in groups: G1 126 individuals, 49 female and 77 male, with gradually falling audiogram configuration; G2 38 individuals, 22 female and 16 male, with a abruptly falling audiogram configuration. The inclusion criteria were: age 60 years old; sensorineural hearing loss (bilateral and symmetrical); individuals not users of hearing aid; absence of cognitive alterations. It was realized the Hearing Noise in Test (HINT), in the mono and binaural modalities, with earphones. The statistical analysis was composed by Multiple Linear Regression. Results: The configuration and degree of hearing loss of highest occurrence was, respectively, abruptly falling and moderate. When considering the audiogram configuration, ISO mean and age as independent variables, the R² adjusted varied in the binaural modality from 28% to 65%, and in the monaural modality from 42% to 65%. About the configuration, degree of hearing loss and age, the R² adjusted varied in the binaural modality from 20% to 48% and in the monaural modality from 37% to 58%. The difference occurred with respect to age, ISO mean and degree of hearing loss (p0.05) in all HINT conditions, except in the left noise condition in the binaural modality, in which there was difference only to the ISO mean. The values of of the ISO mean were higher in comparison to the age. Conclusion: The audiogram configuration did not influence the performance of elderly individuals in the HINT, however, there was influence of age and hearing loss (ISO mean and degree). The hearing loss had a greater influence on speech perception, both in silence and in noise, and in monorail and binaural listening modalities, compared to age.
|
64 |
Aspectos psicológicos da voz e seus correlatos acústicos. / Correlation between psychological aspects of professional voice and acoustic analysisAdriana Campos Balieiro Panico 04 May 2001 (has links)
Neste estudo investigou-se a relação entre aspectos psicológicos (agradabilidade, confiabilidade e naturalidade) de vozes profissionais e parâmetros acústicos (intensidade, freqüência e duração). Os aspectos psicológicos foram previamente definidos através de um questionário aplicado a profissionais da voz. Trechos de fala de repórteres e apresentadores de rádio e televisão (masculinas e femininas) foram gravados em estúdio profissional e analisados acusticamente por meio do programa de computador Dr. Speech 3.0. Posteriormente as gravações foram apresentadas pelo método de comparação aos pares a ouvintes leigos para que estimassem o quão agradável, confiável e natural eram as vozes preferidas em relação às preteridas. As somas das pontuações dos julgamentos estabeleceram escalas decrescentes que ordenavam as vozes mais agradáveis, mais confiáveis e mais naturais; e os valores destas escalas foram correlacionadas com os parâmetros acústicos. Também, para cada aspecto psicológico, foi determinada uma matriz de índices de correlação de Pearson entre as somatórias das pontuações das vozes, que foi submetida a uma análise de escala multidimensional (MDS). Esta análise indicou que as vozes podem ser descritas adequadamente por três dimensões em cada aspecto psicológico. Os valores das escalas dessas dimensões também foram correlacionados com os parâmetros acústicos. Concluiu-se que os julgamentos de agradabilidade, confiabilidade e naturalidade das vozes guardam interdependência entre si. O aspecto confiabilidade teve duas dimensões fortemente correlacionadas com freqüência e intensidade. Para agradabilidade e naturalidade houve concorrência de vários parâmetros acústicos. Sugere-se que no trabalho de impostação de voz se considerem os parâmetros acústicos que se correlacionam fortemente com as dimensões dos aspectos psicológicos. / This study investigated the relation between the psychological aspects (pleasantness, reliability and naturalness) of professional voices and acoustic parameters (intensity, frequency and duration). The psychological aspects were previously determined through a questionary applied to those who use their voices professionally. Parts of the speeches of reporters and radio and television presenters (male and female) were recorded in a professional studio and analyzed acoustically by means of the computer program Dr. Speech 3.0. Subsequently the recordings were presented, by the comparison method, in pairs, to laymen so that they could estimate how pleasant, reliable and natural were the preferred voices in relation to the neglected ones. The sum of the ratings established increasing scales that assorted the most pleasant, most reliable and most natural voices; and the values of those scales were correlated with the acoustic parameters. For each psychological aspect, as well, a Pearson correlation index matrix was determined between the total amounts of the voice ratings, and was submitted to a multidimensional scale analysis (MDS). This analysis indicated that three dimensions in each psychological aspect might adequately describe the voices. The values of the scales of these dimensions were also correlated with the acoustic parameters. The conclusion was that the pleasantness, reliability and naturalness ratings of the voices maintain interdependence among them. The reliability aspect had two dimensions that were strongly correlated with frequency and intensity. For pleasantness and naturalness aspects there was a balance among several of the acoustic parameters. It is suggested that the acoustic parameters that strongly correlate with the dimensions of the psychological aspects should be considered on the voice placement work.
|
65 |
Desenvolvimento de um sofware para avaliação da percepção de fala em crianças deficientes auditivas / Development of a software to assess the speech perception in hearing impaired childrenCamila Angelica Quintino 23 March 2007 (has links)
INTRODUÇÃO: A necessidade de métodos de avaliação da percepção da fala tornou-se imprescindível para as crianças com deficiência auditiva. É importante que tais métodos possibilitem conhecer o nível de desenvolvimento das habilidades auditivas do paciente, auxiliar a indicação e o acompanhamento da efetividade dos aparelhos de amplificação sonora individual e do implante coclear e avaliar o programa de reabilitação auditiva durante o processo terapêutico e/ou educacional Vários são os procedimentos descritos e utilizados para avaliar a percepção de fala, no entanto, cuidados especiais devem ser tomados durante a aplicação desses procedimentos, principalmente com relação ao controle de variáveis, como intensidade do estímulo apresentado, qualidade de voz nas aplicações dos testes e distância entre a fonte sonora e o paciente. Tudo isso para que haja um controle maior dos dados apresentados, favorecendo a sua replicabilidade, principalmente ao apresentar os resultados em pesquisas. OBJETIVO: Desenvolver um software utilizando o protocolo criado por Bevilacqua e Tech (1996) e verificar a aplicabilidade deste software com crianças ouvintes. MÉTODOS: O software foi desenvolvido em parceria com um graduando em análise de sistemas, que utilizou a linguagem de programação java e o banco de dados firebird. Além disso, o software foi aplicado em dez crianças ouvintes de uma escola regular. RESULTADOS: O software apresentou figuras bastante atraentes às crianças e exigiu o manuseio do computador por elas em quatro das seis provas que propõe o protocolo, sendo que as outras duas provas foram controladas pelo avaliador, porém, de acordo com a resposta da criança. Os resultados da aplicação foram muito semelhantes, sendo apresentado para as provas um valor mínimo de acerto de 80%. CONCLUSÕES: O software mostrou-se bastante eficaz utilizando figuras atraentes que favoreceu a motivação e interesse das crianças em realizar o procedimento, além de conseguir controlar a apresentação dos estímulos sonoros e ter um sistema de armazenamento de dados prático e confiável. / INTRODUCTION: The need for speech perception assessment methods became indispensable to assess hearing impaired children. It is important that such methods allow to find the patient´s hearing ability level, to help choosing and assessing the effectiveness of the hearing device and to evaluate the hearing rehabilitation program during therapeutic and/or educational process. There are several procedures described and used to assess the speech perception, however, all require attention to details while applying such procedures, mainly in regards to the control of variants such as the intensity of stimuli presented, voice quality and distance between the sound source and the patient. The purpose of all is to provide improved control over the data presented, making easier its interpretation specially when showing results. OBJECTIVE: To develop a software making use of the protocol created by Bevilacqua e Tech (1996) and to verify its applicability when assessing children with normal hearing. METHOD: The software was developed in partnership with a student majoring as a system analyst, who used the Java computer language and the Firebird database. In addition, the software was used to assess ten children with normal hearing and from a regular school. RESULTS: The software showed the children eye-catching illustrations and required them to handle the computer in four of six tests proposed by the protocol, with the other two tests controlled by the appraiser according to the child´s response. The assessment results were very similar, being 80% of right answers in the minimum. CONCLUSIONS: The software showed a high level of efficacy, using eye-catching illustrations which not only contributed to the motivation and interest of the children to participate in the assessment, but also to control the presentation of sound stimuli and to have a database system more practical and reliable.
|
66 |
Percepção da fala em crianças usuárias de implante coclear com duas estratégias de processamento do sinal do sistema HiResolution / Speech perception in children with cochlear implants with two sound processing strategy of the HiResolution systemTatiana Mendes de Melo 22 October 2012 (has links)
A melhora na percepção da fala dos usuários de implante coclear (IC) ao longo do tempo está relacionada, entre outros fatores, ao avanço tecnológico das estratégias de processamento do sinal. Deste modo, o objetivo deste trabalho foi avaliar o desempenho de percepção da fala em crianças usuárias de IC, utilizando duas diferentes estratégias de processamento do sinal do sistema HiResolution da Advanced Bionics. Para tanto, participaram deste estudo 11 crianças com deficiência auditiva pré-lingual, usuárias do componente interno HiRes 90K e processador de fala modelo platinum, e que apresentavam habilidade auditiva de reconhecimento em conjunto aberto. Foi realizada a avaliação intra-sujeito em três momentos, de acordo com a estratégia de fala utilizada. O desempenho da linha de base foi avaliado com a estratégia HiResolution 120 (HiRes 120) e posteriormente, foi realizada a conversão da estratégia para a HiResolution (HiRes). Após três meses de uso da estratégia HiRes, os participantes foram avaliados e realizada a conversão da estratégia para a HiRes 120. Após três meses de uso da HiRes 120, os participantes foram reavaliados. Em todas as avaliações, os participantes foram submetidos à pesquisa dos limiares audiométricos em campo livre, avaliação da percepção da fala por meio do teste Hearing in Noise (HINT), no silêncio e na presença de ruído competitivo e, avaliação dos benefícios proporcionados pelo uso do IC em situações cotidianas, por meio do questionário Parents\' Evaluation of Aural/oral Performance of Children (PEACH). Os resultados demonstraram que não houve diferença dos limiares audiométricos em campo livre, do desempenho auditivo no silêncio e do benefício do IC em situações de vida diária, em função da estratégia de processamento de sinal utilizada. Houve tendência de melhor desempenho auditivo na situação de ruído com o uso da estratégia de processamento de sinal HiRes 120, embora, tal resultado não tenha sido estatisticamente significante. Essa tendência indica que a representação espectral do sinal acústico de forma mais detalhada proporcionada pela HiRes 120 pode auxiliar no desempenho auditivo de crianças usuárias de IC em situações de ruído, contudo, essa característica da estratégia de processamento de sinal não influenciou o desempenho auditivo nas situações de silêncio. Reforça-se a importância da observação clínica e avaliação de percepção de fala com ruído na seleção da estratégia de processamento de sinal, a fim de otimizar o desempenho auditivo dos usuários de IC. / Improvements in speech perception with cochlear implant (CI) over the years is related, among others factors, to the technological advance of the sound processing strategy. The purpose of the present study was to investigate speech perception performance in CI children, with two different Advanced Bionics sound processing strategy. Subjects were 11 prelingually deafened children implanted with the HiRes 90K cochlear implant and used a bodyworn platinum sound processor. All subjects showed evidence of open-set speech recognition. A within-subjects design was used to compare performance with standard HiRes and HiRes 120. Baseline performance was assessed with HiResolution 120 (HiRes 120). Subjects then were fitted with HiResolution (HiRes) and returned for re-evaluation after three months of use. After three months of HiRes experience, subjects were refitted with HiRes 120 and returned three months later for reassessment. During test sessions, subject\'s performance was evaluated by warble-tone sound-field thresholds, the Brazilian Hearing in Noise test (HINT) in quiet and in noise and Parents\' Evaluation of Aural/oral Performance of Children questionnaire (PEACH). The detection thresholds, the speech perception in quiet and the CI benefit in daily life were similar for both sound processing strategy. There was a trend toward better hearing performance in noise with HiRes 120, although this result was not statistically significant. This trend indicates that more precise spectral representation of the acoustic signal provided by the HiRes 120 can result in an improvement in the speech perception in noise by CI children. However, this characteristic did not influence the auditory performance in quiet. It reinforces the importance of clinical observation and speech perception in noise assessment in the sound processing strategy selection, in order to optimize the auditory performance of CI users.
|
67 |
Influência da amostra de fala no julgamento perceptivo da hipernasalidade / Influence of speech sample on perceptual judgement of hypernasalityMaria Natália Leite de Medeiros 27 February 2015 (has links)
Proposição: Investigar a influência do tipo de amostra de fala, conversa espontânea ou repetição de sentenças, sobre o índice de concordância intra e interavaliadores. Material e Métodos: Foram selecionadas e editadas 120 amostras de fala de indivíduos com fissura de palato±lábio reparada, de ambos os sexos, com idade entre 6 e 52 anos (média=21±10 anos), gravadas em áudio, sendo 60 amostras contendo trechos de conversa espontânea e 60 amostras contendo repetição de sentenças. As amostras foram analisadas por três fonoaudiólogas experientes, as quais classificaram a hipernasalidade em escala de 4 pontos: 1=hipernasalidade ausente, 2=hipernasalidade leve, 3=hipernasalidade moderada e 4=hipernasalidade grave, utilizando seus critérios internos, em duas etapas: primeiramente conversa espontânea e, 30 dias depois, repetição de sentenças. Os índices de concordância intra e interavaliadores foram estabelecidos para ambos os tipos de amostra de fala e foram comparados entre si por meio do Teste Z. Diferenças foram consideradas estatisticamente significantes ao nível de 5%. Resultados: A comparação dos índices de concordância intra-avaliadoras entre os dois tipos de amostra de fala mostrou aumento dos coeficientes obtidos na análise da repetição de sentenças em relação aos obtidos na conversa espontânea, de 0,45 (moderado) para 1,00 (quase perfeito) para a avaliadora 1; de 0,60 (substancial) para 0,74 (substancial) para a avaliadora 2 e de 0,44 (moderada) para 0,92 (substancial) para a avaliadora 3. Diferenças estatisticamente significante foram verificadas para as avaliadoras 1 (p<0,001) e 3 (p=0,006). A comparação entre os índices de concordância interavaliadores mostrou que os coeficientes de concordância obtidos entre as três avaliadoras para as amostras de fala contendo trechos de conversa espontânea variaram de 0,34 (regular) a 0,48 (moderado) e para as amostras com repetição de sentenças de 0,31 (regular) a 0,43 (moderado), não havendo diferença estatisticamente significante entre os dois tipos de amostras (p=0,970). Conclusão: A repetição de sentenças favoreceu a confiabilidade do julgamento perceptivo da hipernasalidade de um mesmo avaliador, visto que a concordância intra-avaliadores na análise desta amostra de fala foi maior. No entanto, o tipo de amostra de fala não influenciou a concordância entre diferentes avaliadores. / Purpose: To investigate the influence of speech material, spontaneous conversation or sentences repetition, on intra and inter-rater reliability. Material and Methods: 120 audio recorded speech samples were selected and edited of individuals with repaired cleft palate±lip, both genders, aged 6 to 52 years old (mean 21±10), 60 samples containing spontaneous conversation and 60 samples containing sentences repetition. Recordings were analyzed by three experienced speech and language therapists, which rated hypernasality according to their own criteria using 4-point scale: 1=absence of hypernasality, 2=mild hypernasality, 3=moderate hypernasality and 4=severe hypernasality. The analyses were performed in two steps: first spontaneous speech and 30 days after, sentences repetition. Intra and inter-rater agreements were calculated for both speech samples and were statistically compared by the Z test. Differences between two speech samples were considered statistically significant at the 5% level. Results: Comparison of intra-rater agreements between both speech samples showed an increase of the coefficients obtained in the analysis of sentences repetition compared to those obtained in spontaneous conversation from 0.45 (moderate) to 1.00 (almost perfect) regarding rater 1; from 0.60 (substantial) to 0.74 (substantial) to rater 2 and from 0.44 (moderate) to 0.92 (substantial) to rater 3. Statistically significant differences were verified to raters 1 (p<0.001) and 3 (p=0.006). Comparison between inter rater agreement showed that the agreement coefficients obtained among the three raters ranged from 0.34 (fair) to 0.48 (moderate) for spontaneous conversation and from 0.31 (fair) to 0.43 (moderate) for sentences repetition with no statistically significant difference between two speech samples (p=0.970). Conclusion: Sentences repetition improved intra-rater reliability of hypernasality. However, the speech material had no influence on reliability among different raters.
|
68 |
Verificação eletroacústica de sistemas de frequência modulada em usuários de implante coclear / Electroacoustic verification of frequency modulation systems in cochlear implant usersVanessa Luisa Destro Fidêncio 06 July 2017 (has links)
O objetivo deste estudo foi realizar e determinar a validade de um protocolo de teste de verificação eletroacústica para Sistemas de Frequência Modulada (FM) acoplados a diferentes processadores de fala de implantes cocleares. Participaram deste estudo 40 crianças, com idades entre 5 e 18 anos incompletos, usuários de quatro modelos diferentes de processadores de fala. A verificação eletroacústica foi realizada por meio do uso do equipamento Audioscan Verifit (VF-1) com acoplador HA-1, além do uso do dispositivo de verificação de escuta correspondente a cada modelo de processador de fala do implante coclear. Nos casos em que a transparência não foi atingida, foi realizada alteração no ajuste do ganho do Sistema FM e avaliação da percepção auditiva da fala no ruído por meio da aplicação da versão brasileira do teste Phrases in Noise Test (PINT). Houve transparência entre o Sistema FM e o implante coclear em 85% dos dispositivos avaliados. Após o ajuste do ganho FM nos outros casos, os dispositivos apresentaram-se transparentes quando o teste de verificação eletroacústica foi repetido. Também foi observado que os participantes submetidos ao teste de percepção de fala no ruído apresentaram melhor desempenho após o novo ajuste, de modo que, nestes casos, a transparência eletroacústica ocasionou em transparência comportamental. Concluiuse que o protocolo de verificação eletroacústica utilizado mostrou-se efetivo para a avaliação da transparência entre o Sistema FM e o implante coclear. A realização prévia do ajuste do processador de fala e do ganho do Sistema FM mostrou-se essencial para que a transparência fosse atingida. / The purpose of this study was perform and determine the validity of an electroacoustic verification test for FM Systems coupled to different cochlear implant speech processors. The sample included 40 participants between 5-18 years users of four different models of speech processors. For the electroacoustic evaluation, we used the Audioscan Verifit device with the HA-1 coupler and the listening check devices corresponding to each speech processor model. In cases where the transparency was not achieved, was made a modification in the FM gain adjustment and used the Brazilian version of the \"Phrases in Noise Test\" (PINT) to evaluate the speech perception in competitive noise. It was observed that there was transparency between the FM System and the cochlear implant in 85% of the participants evaluated. After adjusting the gain of the FM receiver in the other participants, the devices showed transparency when the electroacoustic verification test was repeated. It was also observed that they presented better performance in speech perception in noise after a new adjustment, that is, in these cases, the electroacoustic transparency caused behavioral transparency. It was concluded that the electroacoustic evaluation protocol suggested was effective to evaluate transparency between the FM System and the cochlear implant. Performing the adjustment of the speech processor and the FM System gain are essential when fitting this device.
|
69 |
Desenvolvimento e estudo comparativo de listas de palavras para uso na medida do limiar de reconhecimento de fala em crianças de 5 a 7 anos de idade / Development and comparative study of word lists to use in the speech recognition threshold research in 5 to 7 year-old childrenMárcia Regina Gama 23 September 2004 (has links)
O trabalho teve como objetivo geral discutir a construção de listas de palavras para uso na medida do teste de Limiar de Reconhecimento da Fala (LRF) em crianças com idade entre 5 e 7 anos. O grupo de sujeitos foi constituído por alunos de pré-escola e da 1ª série do ensino fundamental de escolas da rede pública da cidade de Itatiba, São Paulo, otologicamente normais. O trabalho foi estruturado em 3 etapas. A primeira etapa relacionou-se com a construção das listas de palavras experimentais trissilábicas paroxítonas denominadas de LE1 e 2, constituídas a partir de um levantamento feito com programas e filmes infantis de maior audiência pelos grupos etários estudados. Das 672 palavras obtidas, 35 trissílabas paroxítonas foram selecionadas, formando duas listas em ordem aleatória. As listas LRS 1 e 2 foram utilizadas para comparação e retiradas de Russo e Santos (1993), seguindo os mesmos critérios de elaboração. Na segunda etapa, as listas de palavras foram gravadas em estúdio profissional, por um locutor do sexo feminino nativo do português brasileiro. Na terceira etapa o material desenvolvido foi aplicado em um grupo de 94 crianças de 5 a 7 anos de ambos os sexos. Os resultados, na análise quantitativa, não mostraram diferenças estatisticamente significantes entre as variáveis listas, orelhas, faixa etária, ordem de apresentação e sexo. Os resultados do LRF (em deciBel Nível de Sensação) obtidos com as listas LE e LRS situaram-se entre -10 e +15dBNS com média de 4,3dBNS para orelha direita e 4,4dBNS para orelha esquerda. Os dados indicaram que as listas desenvolvidas para a obtenção do LRF, em crianças na faixa etária do estudo, são válidas para este fim. A análise qualitativa indicou algumas das estratégias utilizadas pelos sujeitos no reconhecimento auditivo das palavras da lista E1. / This study provides a discussion about a word list construction to use in the speech recognition threshold. The chosen subjects are pre and first year school children from the Basic Education at public schools in Itatiba, São Paulo Brazil, otologically normal. The study comprises three stages. The first one was the construction of paroxytone trisyllabic word lists called LE1 e 2, consisted of a survey done with juvenile programs and films of bigger audience by the aged studied groups. From the 672 words, 35 paroxytone trisyllables were selected, forming two lists in a random order. The LRS 1 and 2 were used for comparison and they were got from Russo e Santos (1993), following the same criteria. In the second stage, the word lists were recorded in a professional studio by a native speaker. In the third stage, the developed material was applied in a group with 94 children. The results didnt show differences statistically significant among the varied list, the ear, the aged group, the presentation order and the sex. The SRT (dBNS) results obtained with the LE and the LRS lists were placed among -10 and +15 dBNS. The data indicated that the developed lists to obtain the SRT in these children are valid.
|
70 |
Teleprogramação dos sistemas de implante coclear / Teleprogramming of cochlear implant systemsPaola Angelica Samuel 16 April 2015 (has links)
Objetivos: Verificar a efetividade da teleprogramação em pacientes usuários de IC comparando os resultados audiológicos do IC e os parâmetros da programação nas condições remota e presencial; verificar a qualidade de transmissão remota e o grau de compreensão das orientações dadas pelo fonoaudiólogo remotamente. Casuística e método: Foi realizado um ensaio clínico randomizado, tipo cross over, no qual a intervenção remota (à distância) foi comparada à presencial. O desfecho do estudo foi a realização da audiometria em campo livre, testes de percepção de fala, além de questionário e escala VAS para análise da satisfação com o atendimento. Os critérios de seleção foram: idade entre 18 e 59 anos, de ambos os gêneros; usuários de IC da marca Cochlear®, unidade interna Nucleus 24® ou Freedom®, com processador de fala Freedom SP®, e tempo de experiência com implante coclear mínima de 12 meses. Os critérios de exclusão foram: dificuldade de compreensão no questionário realizado no início do estudo e deficiência visual que impossibilite a realização da leitura orofacial. Os participantes realizaram duas sessões de programação no mesmo dia: uma presencial - programação presencial (PP) e outra a distância - programação remota (PR). Os mesmos fonoaudiólogos realizaram as duas sessões de programação e a ordem de realização das programações foi randomizada. Foram comparados os níveis mínimos (níveis T) e níveis máximos de estimulação (níveis C) de cinco eletrodos (1, 6, 11, 16, 22). Foram aplicados testes de percepção de fala (frases closed-set, open-set sem ruído e com relação S/R 0 e 10dB, e monossílabos - todos com gravação a 65dB), audiometria em campo livre nas frequências de 250 a 8000Hz, questionário e escala visual analógica (VAS) para satisfação com o atendimento após as programações. Os resultados da audiometria, testes, questionários e do VAS também foram comparados. Resultados: Participaram 20 usuários de IC, com tempo médio de uso do dispositivo de 43 meses. Na comparação entre os níveis T obtidos na PR e PP, houve diferença estatisticamente significante nos eletrodos 22 e 16 (p<0,05), indicando que os níveis foram mais altos na PR. Na comparação entre níveis C, houve diferença estatisticamente significante nos eletrodos 11 e 6 (p < 0,05), indicando que os níveis foram mais altos na PP. Não foram encontradas diferenças estatisticamente significantes entre os testes de percepção de fala e os limiares auditivos obtidos com os mapas da PR e PP (p > 0,05). A escala VAS mostrou diferença estatisticamente significante, sendo o maior valor atribuído à PP (p=0,018). No questionário aplicado, houve diferença estatisticamente significante nas questões referentes à qualidade e comunicação no atendimento, mostrando que a PP apresentou menor dificuldade de compreensão e comunicação. Conclusão: A teleprogramação é viável e eficaz quando comparada à programação presencial. Embora tenham sido encontradas diferenças nos níveis de estimulação entre as programações realizadas de forma remota e presencial, não houve diferença nos resultados dos testes de percepção de fala e audiometria realizadas nos dois procedimentos. A programação presencial possibilitou maior facilidade de comunicação e satisfação em relação ao atendimento, quando comparada à programação realizada de forma remota / Objectives: To verify the effectiveness of teleprogramming in CI users comparing the audiological results of the IC and the programming parameters in remote and live conditions; to verify the quality of remote transmission and the understanding of the guidance given by the audiologists remotely. Patients and methods: We conducted a randomized controlled trial, with crossover, in which the remote intervention (distance) was compared to the live intervention. The end point was the realization of the free field audiometry, speech perception tests, and questionnaire and VAS scale for analysis of satisfaction with the sections. The selection criteria were: age between 18 and 59 years, of both genders; CI users of Cochlear® device, internal unit Nucleus® 24 or Freedom® with speech processor Freedom® SP, and experience with CI of at least 12 months. Exclusion criteria were: difficulty in understanding the questionnaire completed at baseline and visual disability which makes impossible the realization of lip reading. Participants performed two programming sessions on the same day: a live programming (LP) and a remote programming (RP). The same audiologists conducted the two programming sessions and the order of realization of the sessions was randomized. The minimum (T) and maximum (C) stimulation levels of five electrodes (1, 6, 11, 16, 22) were established. Tests were applied for speech perception using 65dBSNR (closed-set sentences, open-set without noise and speech-in-noise with signal-to noise 0dB and 10db, and monosyllables). The patients were also submitted to free field audiometry from 250 to 8000Hz frequencies, visual analog scale (VAS) and questionnaire after the fittings sections. The results were compared using the Wilcoxon Test. Results: The study included a total of 20 CI users, with average time of use of 43 months. Statistically significant difference was found in the T levels for the electrodes 22 and 16 (p < 0.05), which indicates that levels were higher in RP. Statistically significant difference was found in the C levels for the electrodes 11 and 6 (p < 0.05), which indicates that levels were higher in LP. There were no statistically significant differences between the speech perception tests and thresholds obtained with maps of LP and RP (p > 0.05). The VAS scale showed a statistically significant difference, with the highest scores to LP (p = 0.018). In the questionnaire, there was a statistically significant difference in the questions about quality and communication during the sessions, showing that LP allowed less difficulty of understanding and communication. Conclusion: Teleprogramming is feasible and effective when compared to live programming. Although there were some differences in stimulation levels between the remote and live programming sessions, there was no difference in the results of thresholds in audiometry and speech perception tests performed in the two procedures. The live programming allowed better communication and satisfaction when compared to remote programming
|
Page generated in 0.0759 seconds