• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 61
  • 23
  • 5
  • 1
  • Tagged with
  • 89
  • 89
  • 43
  • 43
  • 25
  • 20
  • 17
  • 17
  • 14
  • 13
  • 13
  • 13
  • 13
  • 10
  • 9
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
81

Évaluation des techniques de micro-extraction/préconcentration et d’échantillonnage passif comme outils de mesure de la contamination du milieu aquatique par des composés organo-halogénés hydrophobes émergents / Evaluation of micro-extraction/preconcentration and passive sampling technique as tools to measure the contamination of the aquatic environment by emergent hydrophobic organic halogenated compounds

Gandolfi, Frédéric 20 December 2013 (has links)
La DCE a pour principale ambition d’harmoniser les politiques de l’eau sur un plan européen et d’atteindre le bon état des eaux d’ici 2015. L’évaluation de ce “bon état” implique en outre de dresser l’inventaire, dans les masses d’eau, des 33 substances prioritaires listées en annexe X de la DCE (annexe X, décision No 2455/2001/EC) et pour lesquelles des normes de qualité environnementales (NQE) ont été fixées (Directive 2013/39/EU). Parmi ces substances figurent les polychloroalcanes (SCCPs) et les polybromodiphényléthers (PBDEs) appartenant à la catégorie des micropolluants halogénés “émergents”. D’un point de vue analytique, leur détermination dans l’eau constitue actuellement un enjeu majeur, tant sur le plan de l’échantillonnage que de la sensibilité.Dans ce contexte, ce travail de thèse s’est attaché au développement d’une méthode d’analyse des SCCPs dans les eaux par SPME couplée à la GC/ECNI-MS. Les limites de quantification inférieures à 0,2 µg.L-1 et son degré d’automatisation font de cette méthode un outil de choix pour assurer le monitoring des milieux aquatiques tels que requis par la DCE. En complément de l’approche classique, un pilote de calibration en laboratoire pour l’étalonnage d’échantillonneurs passifs a pu être mis en place et validé pour la calibration des MESCO avec les HAPs. La participation à un essai interlaboratoire a permis de tester l’applicabilité des MESCO et des SR pour l’analyse des PBDEs en sortie de station d’épuration. Enfin la mise en application des LDPE, SR et MESCO sur l’étang de Berre a permis d’obtenir des résultats encourageants quant à l’applicabilité de ces échantillonneurs passifs pour l’analyse des SCCPs et PBDEs. / In order to achieve good water quality for 2015, the water framework directives (WFD 2000/60/EC and 2013/39/EU) force European countries to monitor the quality of their aquatic environment. For this purpose, all water bodies shall be monitored for all the 33 priority substances listed in annex X of WFD (annex X, decision No 2455/2001/EC) and for which environmental quality standards (EQS) were fixed (Directive 2013/39 / EU). Among these substances, we found the short chain chlorinated paraffins (SCCPs) and the polybrominated diphenyl ethers (PBDEs) belonging to the class of emergent halogenated micro-pollutants. From an analytical point of view, the analysis of SCCPs and PBDEs in water is still a major challenge, either in terms of sampling or sensitivity.In respect of WFD, this thesis work has, among other things, aimed to develop a method to analyze SCCPs in water by using SPME coupled with GC/ECNI-MS. The limit of quantification below 0.2 µg.L-1 and its degree of automation makes this method a tool of choice to ensure the monitoring of the aquatic environment as required by the WFD. In addition to the traditional approach, a laboratory system for passive sampler calibration was also developed and validated to calibrate MESCO for PAHs analysis. Moreover, our participation in an inter-laboratory study, has served to test the applicability of MESCO and SR for the analysis of PBDEs in a waste water treatment plant. Finally the deployment of LDPE, SR and MESCO in Berre lagoon has yielded some encouraging results about applicability of these passive samplers to analyze SCCPs and PBDE in water.
82

Etude de la composition de la surface de Mars : recherche de molécules organiques par analyse physico-chimique in situ avec l’instrument SAM de la mission Mars Science Laboratory / Study of the composition of the Mars' surface : search for organic molecules with in situ physicochemical analysis with the SAM experiment of the Mars Science Laboratory mission

Millan, Maëva 01 December 2016 (has links)
La recherche de molécules organiques à la surface de Mars est l’un des enjeux majeurs pour caractériser son habitabilité passée et/ou présente. C’est l’un des objectifs de la mission spatiale Mars Science Laboratory (MSL) et en particulier de l’instrument Sample Analysis at Mars (SAM) à bord du robot Curiosity. Cette thèse s’inscrit dans l’aide au traitement et l’interprétation des données de SAM, en vue de détecter et d’effectuer l’inventaire des molécules organiques à la surface de Mars. Ces travaux portent en premier lieu sur les performances analytiques du chromatographe en phase gazeuse (CPG) de SAM et sur l’identification des molécules organiques dans les échantillons solides martiens analysés. A cette fin, j’ai étudié les performances de la chaine d’injection et de séparation du CPG de SAM dans les conditions opératoires de vol reproduites en laboratoire. J’ai également créé une base de données des temps de rétention de molécules présentes, et potentiellement présentes sur Mars, qui sert de référence pour le traitement des données de vol. Ces données ont permis d’identifier des molécules organiques dans les échantillons solides martiens et d’expliquer pourquoi certaines d’entre elles, supposées présentes, ne sont pas détectées. La deuxième partie de l’étude est focalisée sur l’impact des minéraux oxychlorés sur les molécules organiques, lors de la pyrolyse. Pour ce faire, j’ai développé une approche systématique d’étude de la pyrolyse de molécules organiques en présence de minéraux oxydants, ayant tous deux une forte probabilité de se trouver à la surface de Mars. J’ai ainsi pu étudier l’évolution et/ou destruction des molécules organiques, déterminer celles pouvant être à l’origine des composés chlorés détectés sur Mars, évaluer l’impact de la concentration en minéraux oxychlorés et celui du paramètre de température de pyrolyse. Les résultats indiquent que le nombre, la nature, et les abondances relatives des composés formés au cours de la pyrolyse, dépendent de la nature des phases minérales et organiques, de la concentration en minéraux oxychlorés et de la température de pyrolyse. / The search for organic molecules at the Mars’ surface is of primary interest to understand its past and/or present habitability. It is one among the main goals of the Mars Science Laboratory (MSL) space mission and especially of the Sample Analysis at Mars (SAM) experiment onboard the Curiosity rover. This thesis deals with the support to the SAM data treatment and interpretation, which aims to detect and inventory the organic molecules at the Mars’ surface. The first part of this work focuses on the analytical capabilities of the SAM gas chromatograph (GC) and the identification of the organics in the solid samples analysed on Mars with the flight model. To do so, I studied the analytical chain from injection to separation of the SAM GC in the flight operating conditions reproduced in the laboratory. I also created a library of retention times for molecules present or potentially present on Mars, and used as a reference library to treat the flight data. These data allowed to identify the organics in the martian solid samples, and to explain why a few molecules, expected to be present, are not detected. The second part of the thesis focuses on the impact of oxychlorine phases on the organics, during the pyrolysis process. With this aim, I developed a systematic approach to study the pyrolysis of organic molecules on the presence of oxidant minerals that have a high probability of presence at the Mars surface.The evolution and/or destruction of the organics was evaluated. We also looked for the organic and inorganic compounds that can be the precursors of the chlorohydrocarbons detected on Mars with SAM. Finally, we evaluated the influence of the oxychlorines concentration and of the pyrolysis temperature parameter. The results show that the number, the nature and the relative abundances of the compounds formed during the pyrolysis, depend on the nature of the organic and inorganic phases, of the concentration of the oxychlorines phases and of the pyrolysis temperature.
83

Vers des assemblages de complexes métalliques oligonucléaires, servant d’antenne solaire au niveau moléculaire

Chartrand, Daniel 12 1900 (has links)
Les fichiers additionnels sont les données cristallographiques en format CIF. Voir le site de la Cambridge Crystallographic Data Centre pour un visualiseur: http://www.ccdc.cam.ac.uk / Ce projet de recherche vise l’élaboration de systèmes métallosupramoléculaires artificiels imitant le processus naturel de la photosynthèse. Idéalement, ces systèmes seraient capables de fournir l’énergie et la séparation de charge nécessaire pour catalyser des réactions à transfert multiélectroniques, tel que l’hydrolyse de l’eau ou la réduction du gaz carbonique. La réalisation d’un tel système catalytique créerait une source d’énergie renouvelable, sous forme d’énergie chimique, crée directement à partir de l’énergie solaire. Le système envisagé, schématisé sous la forme d’une antenne, possède trois parties distinctes. Tout d’abord, des chromophores forment un état excité en captant l’énergie de la lumière visible du soleil. Vient ensuite un centre de liaison qui lie tous les chromophores et qui collecte l’énergie de cet état excité à travers un transfert d’électron. Cet électron est de nouveau transféré vers la dernière partie, un centre réactionnel catalytique. Cet assemblage permet de créer une séparation de charge entre le chromophore et le centre réactionnel qui sont séparés par le centre de liaison, évitant ainsi la recombinaison de charge. Le projet se focalise sur la synthèse, la caractérisation et l’application en photocatalyse d’assemblages chromophore–centre de liaison–catalyseur. Tout d’abord, une étude de chromophores à base de fluorène et de rhénium a été effectuée dans le but d’évaluer le transfert électronique entre ces deux composants. Ensuite, des centres de liaisons à base de dimère de rhodium tétraamidinate ont été créés et étudiés afin d’établir leurs caractéristiques photophysiques et électrochimiques. Puis un d’entre eux a été assemblé avec des chromophores de rhénium, créant ainsi des espèces moléculaires discrètes contenant d’un à quatre chromophores. Et pour finir, ces assemblages ont été combinés avec un catalyseur à base de cobalt, puis ont été testés dans des expériences de photoproduction d’hydrogène. Cette dernière partie a requis l’élaboration d’un photoréacteur qui est aussi décrite en détail dans cet ouvrage. / This research project involves synthetic metallosupramolecular systems developed to mimic the natural process of photosynthesis. Ideally, these systems would be able to provide the energy and the charge separation needed to catalyze multielectron-transfer reactions, such as water-splitting or carbon dioxide reduction. The realization of such a catalytic system would create a renewable energy source, in the form of chemical energy, created directly from solar energy. The system envisioned has three distinct parts in the form of an antenna. First of all, chromophores go into an excited state, while capturing the visible light energy of the Sun. Then comes a hub which binds all the chromophores and collects this excited state energy through an electron transfer. This electron is then transferred again to the last part, a catalytic reaction center. This assembly creates a charge separation between the chromophore and the reaction center which are separated by the hub, thus avoiding the recombination of charge. The project focuses on the synthesis, characterization and application in photocatalysis of chromophore-hub-catalyst assemblies. First of all, a study of fluorene and rhenium based chromophores was made to assess the electronic transfer between these two components. Then, tetraamidinate rhodium dimer based hubs have been created and studied in order to establish their photophysical and electrochemical characteristics. Then one of these assemblies was formed with chromophores of rhenium, thus creating discrete molecular species containing one to four chromophores. And finally, these assemblies were combined with a cobalt-based catalyst and were tested for hydrogen photoproduction. The latter required the development of a photoreactor which is also described in detail in this thesis.
84

Procédé d'élimination de la pollution de l'air par traitement photocatalytique : application aux COVs / Remediation process of air polllution using photocatalytic treatment : study of VOCs

Vincent, Guillaume 04 September 2008 (has links)
L’oxydation photocatalytique des Composés Organiques Volatils (COVs) apparaît comme un procédé très prometteur pour la réduction de la pollution atmosphérique. Ce travail avait pour objectif d’étudier l’oxydation photocatalytique de plusieurs COVs au sein d’un réacteur annulaire: méthyléthylcétone (MEK), acétone, 1-propanol ou encore triéthylamine (TEA). Dans une première partie, l’influence de plusieurs paramètres cinétiques tels que la concentration en polluant, l’intensité lumineuse, le temps de contact et le taux d’humidité a été étudiée. Un mécanisme de dégradation photocatalytique a été établi pour chaque polluant en fonction des sous-produits détectés par GC/MS. Dans une seconde partie, la diffusion de radicaux hydroxyles OH• dans la phase gazeuse, après activation photonique du TiO2, a été mise en évidence par Fluorescence Induite par Laser (LIF). Pour la première fois, ces radicaux OH• ont été détectés à des pressions proches des conditions atmosphériques. Dans ce cas, nous pouvons en conclure que la dégradation photocatalytique des COVs pourrait être partiellement due à une réaction en phase gazeuse entre les COVs et les radicaux OH• / Photocatalytic oxidation of airborne contaminants appears to be a promising process for remediation of air polluted by Volatile Organic Compounds (VOCs). The aim of our study is the photocatalytic oxidation of several VOCs using an annular reactor: methylethylketone (MEK), acetone, 1-propanol and triethylamine (TEA). First, the influence of different kinetic parameters such as pollutant concentration, incident light irradiance, contact time and humidity has been studied. A mechanistic pathway has been indeed proposed for each pollutant according to the produced intermediates species detected by GC/MS. Second, the diffusion of hydroxyls radicals OH• in gas phase, after photonic activation of TiO2, has been highlighted using Laser-Induced Fluorescence (LIF). For the first time, OH• radicals have been detected at atmospheric pressures, close to the major photocatalytic oxidation conditions, leading to the assumption that the photocatalytic degradation of VOCs might be at least partially occurs between pollutants and OH• radicals in gas-phase
85

Fractionation, chemical and toxicological characterization of tobacco smoke components

Kaur, Navneet 08 1900 (has links)
La fumée du tabac est un aérosol extrêmement complexe constitué de milliers de composés répartis entre la phase particulaire et la phase vapeur. Il a été démontré que les effets toxicologiques de cette fumée sont associés aux composés appartenant aux deux phases. Plusieurs composés biologiquement actifs ont été identifiés dans la fumée du tabac; cependant, il n’y a pas d’études démontrant la relation entre les réponses biologiques obtenues via les tests in vitro ou in vivo et les composés présents dans la fumée entière du tabac. Le but de la présente recherche est de développer des méthodes fiables et robustes de fractionnement de la fumée à l’aide de techniques de séparation analytique et de techniques de détection combinés à des essais in vitro toxicologiques. Une étude antérieure réalisée par nos collaborateurs a démontré que, suite à l’étude des produits de combustion de douze principaux composés du tabac, l’acide chlorogénique s’est avéré être le composé le plus cytotoxique selon les test in vitro du micronoyau. Ainsi, dans cette étude, une méthode par chromatographie préparative en phase liquide a été développée dans le but de fractionner les produits de combustion de l’acide chlorogénique. Les fractions des produits de combustion de l’acide chlorogénique ont ensuite été testées et les composés responsables de la toxicité de l’acide chlorogénique ont été identifiés. Le composé de la sous-fraction responsable en majeure partie de la cytoxicité a été identifié comme étant le catéchol, lequel fut confirmé par chromatographie en phase liquide/ spectrométrie de masse à temps de vol. Des études récentes ont démontré les effets toxicologiques de la fumée entière du tabac et l’implication spécifique de la phase vapeur. C’est pourquoi notre travail a ensuite été focalisé principalement à l’analyse de la fumée entière. La machine à fumer Borgwaldt RM20S® utilisée avec les chambres d’exposition cellulaire de British American Tobacco permettent l’étude in vitro de l’exposition de cellules à différentes concentrations de fumée entière du tabac. Les essais biologiques in vitro ont un degré élevé de variabilité, ainsi, il faut prendre en compte toutes les autres sources de variabilité pour évaluer avec précision la finalité toxicologique de ces essais; toutefois, la fiabilité de la génération de la fumée de la machine n’a jamais été évaluée jusqu’à maintenant. Nous avons donc déterminé la fiabilité de la génération et de la dilution (RSD entre 0,7 et 12 %) de la fumée en quantifiant la présence de deux gaz de référence (le CH4 par détection à ionisation de flamme et le CO par absorption infrarouge) et d’un composé de la phase particulaire, le solanesol (par chromatographie en phase liquide à haute performance). Ensuite, la relation entre la dose et la dilution des composés de la phase vapeur retrouvée dans la chambre d’exposition cellulaire a été caractérisée en utilisant une nouvelle technique d’extraction dite par HSSE (Headspace Stir Bar Sorptive Extraction) couplée à la chromatographie en phase liquide/ spectrométrie de masse. La répétabilité de la méthode a donné une valeur de RSD se situant entre 10 et 13 % pour cinq des composés de référence identifiés dans la phase vapeur de la fumée de cigarette. La réponse offrant la surface maximale d’aire sous la courbe a été obtenue en utilisant les conditions expérimentales suivantes : intervalle de temps d’exposition/ désorption de 10 0.5 min, température de désorption de 200°C pour 2 min et température de concentration cryogénique (cryofocussing) de -75°C. La précision de la dilution de la fumée est linéaire et est fonction de l’abondance des analytes ainsi que de la concentration (RSD de 6,2 à 17,2 %) avec des quantités de 6 à 450 ng pour les composés de référence. Ces résultats démontrent que la machine à fumer Borgwaldt RM20S® est un outil fiable pour générer et acheminer de façon répétitive et linéaire la fumée de cigarette aux cultures cellulaires in vitro. Notre approche consiste en l’élaboration d’une méthodologie permettant de travailler avec un composé unique du tabac, pouvant être appliqué à des échantillons plus complexes par la suite ; ex : la phase vapeur de la fumée de cigarette. La méthodologie ainsi développée peut potentiellement servir de méthode de standardisation pour l’évaluation d’instruments ou de l’identification de produits dans l’industrie de tabac. / Tobacco smoke is an extremely complex aerosol composed of thousands of constituents distributed amongst the particulate and vapor phases. Toxicological effects have been linked to compounds present in both of these phases. Many biologically active compounds have been identified within tobacco smoke; however, there is a lack of studies correlating specific in vitro or in vivo biological responses to components within whole tobacco smoke. The goal of this research was to develop reliable and robust smoke fractionation methods using analytical separation and detection techniques in combination with in vitro toxicological assays. In a previous study by our collaborators, toxicological assessment of the particulate phase combustion products of twelve individual tobacco components revealed that the combustion products of chlorogenic acid were the most cytotoxic using the in vitro micronucleus test. Therefore, a preparative liquid chromatography method was developed in this work to fractionate the combustion products of chlorogenic acid to assess the bioactivity of these fractions and to identify the compounds responsible for the toxicity observed. The sub-fraction responsible for the most cytotoxic response comprised catechol, which was identified by liquid chromatography/time-of-flight mass spectrometry. Emerging studies have highlighted the toxicological significance of whole tobacco smoke and specifically the vapor phase, which shifted our focus to whole smoke analyses. The Borgwaldt RM20S® smoking machine in combination with British American Tobacco’s in vitro cell exposure chamber allow for the generation of fresh cigarette smoke in various doses and delivery to cell cultures. In vitro biological assays have a high degree of variability, thus, all other sources of variability must be accounted for to accurately assess toxicological endpoints; however, the reliability of dose delivery of the instrument had not been assessed until now. We have determined the reliability (RSD from 0.7-12%) of smoke generation and dilution by quantifying two reference standard gases (CH4 by flame ionization detection and CO by infrared absorption) and the tobacco particulate phase marker, solanesol (by high performance liquid chromatography-ultraviolet absorption detection). The relationship between dose and diluted vapor phase components found within the exposure chamber was then characterized by developing a headspace stir-bar sorptive extraction-gas chromatography/mass spectrometry method. The method repeatability gave an RSD from 10-13% for five reference compounds identified in the vapor phase of cigarette smoke. The maximal peak area response was obtained using the following experimental conditions: exposure-to-desorption time interval of 10  0.5 min, desorption temperature of 200 °C for 2 min, and a cryofocussing temperature of -75 °C. The dilution precision was found to yield a linear response of analyte abundance and was observed to be a function of concentration (RSD from 6.2-17.2 %) with quantities of 6-450 ng for the reference compounds. The findings obtained suggest the Borgwaldt RM20S® is a reliable tool to generate and deliver repeatable and linear doses of cigarette smoke to in vitro cell cultures. Our approach began with designing the methodology to work with an individual tobacco component, which could then be applied to a more complex sample, e.g., the vapor phase of cigarette smoke. The methodology developed can potentially serve as standardized methods for the assessment of instrumentation or screening of products for the Tobacco Industry.
86

Fractionation, chemical and toxicological characterization of tobacco smoke components

Kaur, Navneet 08 1900 (has links)
La fumée du tabac est un aérosol extrêmement complexe constitué de milliers de composés répartis entre la phase particulaire et la phase vapeur. Il a été démontré que les effets toxicologiques de cette fumée sont associés aux composés appartenant aux deux phases. Plusieurs composés biologiquement actifs ont été identifiés dans la fumée du tabac; cependant, il n’y a pas d’études démontrant la relation entre les réponses biologiques obtenues via les tests in vitro ou in vivo et les composés présents dans la fumée entière du tabac. Le but de la présente recherche est de développer des méthodes fiables et robustes de fractionnement de la fumée à l’aide de techniques de séparation analytique et de techniques de détection combinés à des essais in vitro toxicologiques. Une étude antérieure réalisée par nos collaborateurs a démontré que, suite à l’étude des produits de combustion de douze principaux composés du tabac, l’acide chlorogénique s’est avéré être le composé le plus cytotoxique selon les test in vitro du micronoyau. Ainsi, dans cette étude, une méthode par chromatographie préparative en phase liquide a été développée dans le but de fractionner les produits de combustion de l’acide chlorogénique. Les fractions des produits de combustion de l’acide chlorogénique ont ensuite été testées et les composés responsables de la toxicité de l’acide chlorogénique ont été identifiés. Le composé de la sous-fraction responsable en majeure partie de la cytoxicité a été identifié comme étant le catéchol, lequel fut confirmé par chromatographie en phase liquide/ spectrométrie de masse à temps de vol. Des études récentes ont démontré les effets toxicologiques de la fumée entière du tabac et l’implication spécifique de la phase vapeur. C’est pourquoi notre travail a ensuite été focalisé principalement à l’analyse de la fumée entière. La machine à fumer Borgwaldt RM20S® utilisée avec les chambres d’exposition cellulaire de British American Tobacco permettent l’étude in vitro de l’exposition de cellules à différentes concentrations de fumée entière du tabac. Les essais biologiques in vitro ont un degré élevé de variabilité, ainsi, il faut prendre en compte toutes les autres sources de variabilité pour évaluer avec précision la finalité toxicologique de ces essais; toutefois, la fiabilité de la génération de la fumée de la machine n’a jamais été évaluée jusqu’à maintenant. Nous avons donc déterminé la fiabilité de la génération et de la dilution (RSD entre 0,7 et 12 %) de la fumée en quantifiant la présence de deux gaz de référence (le CH4 par détection à ionisation de flamme et le CO par absorption infrarouge) et d’un composé de la phase particulaire, le solanesol (par chromatographie en phase liquide à haute performance). Ensuite, la relation entre la dose et la dilution des composés de la phase vapeur retrouvée dans la chambre d’exposition cellulaire a été caractérisée en utilisant une nouvelle technique d’extraction dite par HSSE (Headspace Stir Bar Sorptive Extraction) couplée à la chromatographie en phase liquide/ spectrométrie de masse. La répétabilité de la méthode a donné une valeur de RSD se situant entre 10 et 13 % pour cinq des composés de référence identifiés dans la phase vapeur de la fumée de cigarette. La réponse offrant la surface maximale d’aire sous la courbe a été obtenue en utilisant les conditions expérimentales suivantes : intervalle de temps d’exposition/ désorption de 10 0.5 min, température de désorption de 200°C pour 2 min et température de concentration cryogénique (cryofocussing) de -75°C. La précision de la dilution de la fumée est linéaire et est fonction de l’abondance des analytes ainsi que de la concentration (RSD de 6,2 à 17,2 %) avec des quantités de 6 à 450 ng pour les composés de référence. Ces résultats démontrent que la machine à fumer Borgwaldt RM20S® est un outil fiable pour générer et acheminer de façon répétitive et linéaire la fumée de cigarette aux cultures cellulaires in vitro. Notre approche consiste en l’élaboration d’une méthodologie permettant de travailler avec un composé unique du tabac, pouvant être appliqué à des échantillons plus complexes par la suite ; ex : la phase vapeur de la fumée de cigarette. La méthodologie ainsi développée peut potentiellement servir de méthode de standardisation pour l’évaluation d’instruments ou de l’identification de produits dans l’industrie de tabac. / Tobacco smoke is an extremely complex aerosol composed of thousands of constituents distributed amongst the particulate and vapor phases. Toxicological effects have been linked to compounds present in both of these phases. Many biologically active compounds have been identified within tobacco smoke; however, there is a lack of studies correlating specific in vitro or in vivo biological responses to components within whole tobacco smoke. The goal of this research was to develop reliable and robust smoke fractionation methods using analytical separation and detection techniques in combination with in vitro toxicological assays. In a previous study by our collaborators, toxicological assessment of the particulate phase combustion products of twelve individual tobacco components revealed that the combustion products of chlorogenic acid were the most cytotoxic using the in vitro micronucleus test. Therefore, a preparative liquid chromatography method was developed in this work to fractionate the combustion products of chlorogenic acid to assess the bioactivity of these fractions and to identify the compounds responsible for the toxicity observed. The sub-fraction responsible for the most cytotoxic response comprised catechol, which was identified by liquid chromatography/time-of-flight mass spectrometry. Emerging studies have highlighted the toxicological significance of whole tobacco smoke and specifically the vapor phase, which shifted our focus to whole smoke analyses. The Borgwaldt RM20S® smoking machine in combination with British American Tobacco’s in vitro cell exposure chamber allow for the generation of fresh cigarette smoke in various doses and delivery to cell cultures. In vitro biological assays have a high degree of variability, thus, all other sources of variability must be accounted for to accurately assess toxicological endpoints; however, the reliability of dose delivery of the instrument had not been assessed until now. We have determined the reliability (RSD from 0.7-12%) of smoke generation and dilution by quantifying two reference standard gases (CH4 by flame ionization detection and CO by infrared absorption) and the tobacco particulate phase marker, solanesol (by high performance liquid chromatography-ultraviolet absorption detection). The relationship between dose and diluted vapor phase components found within the exposure chamber was then characterized by developing a headspace stir-bar sorptive extraction-gas chromatography/mass spectrometry method. The method repeatability gave an RSD from 10-13% for five reference compounds identified in the vapor phase of cigarette smoke. The maximal peak area response was obtained using the following experimental conditions: exposure-to-desorption time interval of 10  0.5 min, desorption temperature of 200 °C for 2 min, and a cryofocussing temperature of -75 °C. The dilution precision was found to yield a linear response of analyte abundance and was observed to be a function of concentration (RSD from 6.2-17.2 %) with quantities of 6-450 ng for the reference compounds. The findings obtained suggest the Borgwaldt RM20S® is a reliable tool to generate and deliver repeatable and linear doses of cigarette smoke to in vitro cell cultures. Our approach began with designing the methodology to work with an individual tobacco component, which could then be applied to a more complex sample, e.g., the vapor phase of cigarette smoke. The methodology developed can potentially serve as standardized methods for the assessment of instrumentation or screening of products for the Tobacco Industry.
87

Étude de micropoutres sérigraphiées pour des applications capteurs

Lakhmi, Riadh 18 November 2011 (has links)
Dans cette thèse, des structures MEMS de type micropoutre ont été conçues pour des applications capteurs. Un procédé de fabrication alternatif au silicium, associant la technique de sérigraphie à l'utilisation d’une couche sacrificielle (SrCO3), a été utilisé pour la réalisation de micropoutres piezoélectriques (PZT, matériau servant à la fois d’actionneur et de transducteur) dans un premier temps. Des tests de détection en phase gazeuse ont été réalisés avec et sans couche sensible avec succès à l’aide du mode de vibration non conventionnel 31-longitudinal. Le toluène a notamment pu être détecté à des concentrations voisines de 20ppm avec une couche sensible PEUT. D’autres espèces telles que l’eau, l’éthanol ou l’hydrogène ont été détectés sans couches sensibles afin de s’affranchir des contraintes liées à celle-ci (vieillissement notamment). Des tests préliminaires de caractérisation en milieu liquide ont également été réalisés avec dans l’optique la détection d’espèces en phase liquide. Par ailleurs, un capteur de force a été conçu et réalisé avec le même procédé de fabrication. Ce dernier est composé d’une micropoutre en matériau diélectrique sur laquelle est intégrée une piezorésistance servant à la transduction du signal associé à la déformation subie par la micropoutre. Des détections de force en mode statique (sans actionneurs) ont permis de caractériser les capteurs, notamment en termes de sensibilité, de gamme de force et de force minimale détectable ou encore de linéarité. / The project concerns the conception, fabrication and characterization of cantilever-type MEMS structures for sensors applications. An alternative process to silicon related ones, associating the screen-printing technique to a sacrificial layer (SrCO3), was used to realize piezoelectric cantilevers (PZT material utilized as actuator and transducer) in a first time. Detections in gas phase were performed successfully with and without sensitive layer thanks to the unusual 31-longitudinal vibration mode. Namely, we were able to detect toluene at concentrations as low as 20ppm with a PEUT sensitive layer. Other species like water, ethanol or hydrogen could be detected without sensitive layer in order to get rid of the sensitive layer-related issues (ageing for example). Preliminary characterizations were carried out in liquid phase in a view to perform liquid phase detection. Besides, a cantilever-based force sensor, fabricated thanks to the same fabrication process was designed. This last one integrates a piezoresistor allowing the transduction of the mechanical signal linked to the strain overcome by the microcantilever. Force detections in static mode (without any actuator) permitted the sensors’ characterization. Indeed, their sensitivity, force range, minimal detectable force and linearity were carried out.
88

Réactivité chimique en phase gazeuse de molécules organiques d’intérêt atmosphérique et astrophysique / Chemical reactivity in gaz-phase of organic molécules of atmospherical and astrophysical interests

Sleiman, Chantal 25 November 2014 (has links)
Cette thèse reporte l'étude expérimentale de la cinétique en phase gazeuse de plusieurs réactions d'intérêt atmosphérique et astrophysique. La connaissance des constantes de vitesse de ces réactions est utile à la compréhension des processus de synthèse et de destruction des molécules dans l'atmosphère terrestre et dans le milieu interstellaire. Sur le plan atmosphérique, nous avons étudié les réactions d'une série d'hydroxycétones, une sous-famille de COV carbonylés, (4-hydroxy-2-butanone, 3-hydroxy-3-méthyl-2-butanone and 4-hydroxy-4-méthyl-2-pentanone) avec le radical OH et l'atome de Chlore Cl afin de définir leur devenir atmosphérique. Nous avons déterminé les constantes de vitesse des réactions de ces hydroxycétones avec le radical OH en absolue à température ambiante et en fonction de la pression en utilisant la cellule cryogénique couplée à la technique PLP-LIF (Photolyse à Laser Pulsé – Fluorescence Induite par Laser). Les constantes de vitesse des réactions de ces hydroxycétones avec Cl ont été mesurées en relative à température ambiante et à pression atmosphérique en utilisant les chambres de simulation atmosphérique couplées aux techniques analytiques de détection : FTIR et GC-MS. En plus, une étude mécanistique a été menée également afin d'identifier et quantifier les produits issus de ces réactions. L'ensemble des résultats obtenus est discuté et nous a permis d'évaluer les implications atmosphériques de ces hydroxycétones (durée de vie et impact sur l'environnement). Le plan astrophysique, la cinétique des réactions impliquant le radical CN et une série de molécules azotées (méthyamine, diméthylamine, triméthylamine et acétonitrile) ont été étudiés sur une large gamme de température (23 K – 354 K) en utilisant la technique CRESU (Cinétique de Réaction en Écoulement Supersonique Uniforme) et la cellule cryogénique couplées à la technique de détection PLP-LIF. Ces études expérimentales ont été accompagnées par des études théoriques afin de mieux comprendre les mécanismes réactionnels. Les éventuelles implications astrophysiques de l'ensemble de ces résultats ont fait l'objet d'une discussion détaillée. / This thesis reports the experimental kinetic study of the gas phase reactions of atmospheric and astrophysical interests. The knowledge of the reactions rate constants is useful to understand the mechanisms of formation and destruction of molecules in the Earth’s atmosphere and in the interstellar medium. On the atmospheric side, we have studied the reactions of a series of hydroxyketones (4-hydroxy-2-butanone, 3-hydroxy-3-methyl-2-butanone and 4-hydroxy-4-methyl-2-pentanone), a large category of hydroxycarbonyls with OH radicals and chlorine atoms Cl in order to determine their atmospheric fate. We have measured the absolute rate constants of the reactions of hydroxyketones with OH radicals by using the cryogenic cell coupled to PLP-LIF technique (Pulsed Laser Photolysis - Laser Induced Fluorescence) at room temperature and as function of pressure. The relative rate constants of the reactions of the compounds investigated with Cl atoms were measured at room temperature and atmospheric pressure by using the atmospheric simulation chamber coupled to the analytical detection techniques: FTIR and GC-MS. In addition, a mechanistic study was also conducted in order to identify and quantify the products formed from these reactions. The whole results are discussed in order to assess the atmospheric implications of these hydroxyketones (lifetimes and environmental impact). On the astrophysical side, the kinetic of the reactions involving CN radical and a series of nitrogen-containing molecules (methylamine, dimethylamine, trimethylamine and acetonitrile) was studied over a wide range of temperature (23 K - 354 K) using CRESU technique (a French acronym standing for Cinétique de Réaction en Ecoulement Supersonique Uniforme) and the cryogenic cell coupled to the detection technique PLP-LIF. These experimental studies were accompanied by theoretical studies to better understand the reaction mechanisms. Possible astrophysical implications of the whole results have been discussed in this study.
89

Optimization of differential ion mobility and segmented ion fractionation to improve proteome coverage

Wu, Zhaoguan 09 1900 (has links)
La sensibilité et la profondeur de l'analyse protéomique sont limitées par les ions isobares et les interférences qui entravent l'identification des peptides de faible abondance. Lorsque nous analysons des échantillons de grande complexité, une séparation extensive de l'échantillon est souvent nécessaire pour étendre la couverture protéomique. Ces dernières années, la spectrométrie de mobilité ionique à forme d'onde asymétrique à haut champ (FAIMS) a gagné en popularité dans le domaine de la protéomique pour sa capacité à séparer les ions isobares, à améliorer la capacité de pic et la sensibilité de la spectrométrie de masse (MS). Nous rapportons ici l'intégration d'un appareil FAIMS Pro™ à un Q-Exactive HF™ ainsi qu'un spectromètre de masse Orbitrap Exploris 480™. Des expériences protéomiques sur des digestions d'extraits protéiques issues de cellules Hela à l'aide d'un spectromètre de masse avec FAIMS ont amélioré le rapport signal sur bruit (S/N) et réduit les ions interférents, ce qui a entraîné une augmentation du taux d'identification des peptides de plus de 42 %. FAIMS est également combiné avec le fractionnement ionique segmenté (SIFT), qui utilise tour à tour une fenêtre de 100 ~ 300 m/z au lieu de la large plage traditionnelle (700 ~ 800 m/z), augmentant ainsi la profondeur de la couverture protéomique tout en réduisant la proportion de spectres MS/MS chimériques de 50% à 27%. Dans l'analyse quantitative, nous démontrons l'application de FAIMS pour améliorer les mesures quantitatives lorsque le marquage peptidique isobare est utilisé. Par rapport aux expériences LC-MS/MS conventionnelles, la combinaison des expériences FAIMS et SIFT réalisées sur un modèle à deux protéomes a montré une amélioration de 65 % de la précision des mesures quantitatives. Les digestions tryptiques d'extraits protéiques de différentes lignées cellulaires du cancer colorectal ont été utilisées pour l'évaluation de stratégie combinée FAIMS et SIFT sur un spectromètre de masse Orbitrap Exploris 480™ offre un gain d'identification de 70 % par rapport à l'approche conventionnelle et combinée aux données transcriptomiques elle facilite l’identification de variants protéiques. / The sensitivity and depth of proteomic analysis in mass spectrometry (MS) is limited by isobaric ions and interferences that hinder the identification of low-abundance peptides. For high complexity samples, extensive separation is often required to expand proteomic coverage. In recent years, high-field asymmetric waveform ion mobility spectrometry (FAIMS) has gained popularity in the field of proteomics for its ability to resolve confounding ions, improve peak capacity, and sensitivity. This thesis presents the integration of a FAIMS Pro™ interface with electrical and gas embedded connections to a Q-Exactive HF™ as well as an Orbitrap Exploris 480™ mass spectrometer. Proteomic experiments on tryptic digests of HeLa cell line using a FAIMS integrated mass spectrometer improved signal-to-noise ratio (S/N) and reduced the occurrence of interfering ions. This enabled a 42% increase in peptide identification rate. Also, FAIMS was combined with segmented ion fractionation (SIFT), which in turn scans with windows of 100~300 m/z width instead of the traditional width (700~800 m/z), further increasing the depth of proteome coverage by a reducing from 50% to 27% in terms of MS/MS chimeric spectra numbers. The application of FAIMS gain improvement on quantitative measurements with TMT labeling method is presented. Compared to conventional LC-MS/MS tests, the combination of FAIMS and SIFT experiments showed a improvement by 65% in quantitative accuracy when performed on a human-yeast two-proteome model. As an application of the method, the tryptic digests from different colorectal cancer cell lines were used for the evaluation. FAIMS-SIFTcombined strategy on an Orbitrap Exploris 480™ mass spectrometer provides a 70% gain in identification compared to the conventional LC-MS/MS approach for the same sample amount and instrument time. This enhanced sensitivity facilitates single amino acid mutations confirmed by RNAseq analyses.

Page generated in 0.0361 seconds