• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 16
  • 12
  • 5
  • 5
  • 1
  • 1
  • 1
  • Tagged with
  • 57
  • 20
  • 16
  • 14
  • 13
  • 9
  • 9
  • 9
  • 9
  • 5
  • 5
  • 5
  • 5
  • 5
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Mécanismes de vieillissement de l'Assemblage-Membrane-Électrodes dans une pile à combustible de type PEM par approche expérimentale / Mechanisms of Membrane-Electrode-Assembly aging in PEMFC by experimental approach

Huang, Botao 17 July 2012 (has links)
Cette thèse a permis de mettre en évidence les mécanismes de vieillissement de la pile à combustible de type PEM lors de cyclages d'humidité de l'air et suite à la perforation de l'AME (Assemblage Membrane Electrodes). Premièrement, les mécanismes connus de dégradation des divers composants (membrane, catalyseur, support du catalyseur, GDL, plaques bipolaires et joints d'étanchéité) ont été présentés. Ensuite, les outils de diagnostic en-ligne (chronopotentiométrie, spectroscopie d'impédance, gestion de l'eau et analyse chimique de l'eau) et ceux hors-ligne (CV et LSV) ainsi que des analyses post-mortem (RMN, MET, MEB et DRX) ont été décrits. Expérimentalement, le cyclage en humidité de l'air a été effectué en mono-cellule de 25 cm2: le cyclage à forte humidité entraîne une perte significative de la surface électroactive du catalyseur; le cyclage à faible humidité favorise la perméation de l'hydrogène à travers la membrane. Le cyclage à faible humidité réalisé sur une pile de 100 cm2 a montré un mécanisme de dégradation différent de celui de la pile de 25 cm2: la perméation de l'hydrogène reste faible alors que la tension de la pile était de plus en plus fluctuante certainement du fait de la présence de volumes morts et de la rétention d'eau liquide dans la pile. L'effet de la perforation de l'AME a été étudié sur une pile de 100 cm2: la perforation par une punaise de 0,7 mm de diamètre ne génère qu'une légère augmentation de la perméation de l'hydrogène; la perforation par une punaise de 1,2 mm de diamètre entraîne une chute de tension et l'augmentation significative de la résistance de diffusion de l'oxygène due à la perméation importante de l'hydrogène / This thesis highlights the aging mechanisms of PEM Fuel Cell submitted to two main aging conditions: air relative humidity (RH) cycling, and MEA (Membrane Electrode Assembly) pinhole test of operation. First, the aging mechanisms of PEMFC main components (membrane, catalyst, carbon support, GDL, bipolar plates and gaskets), have been reviewed from the literature. Then the on-line diagnostic tools (chronopotentiometry, electrochemical impedance spectroscopy, water management and water analysis), off-line ones (cyclic voltammetry and linear sweep voltammetry) and post-mortem analyses (nuclear magnetic resonance, transmission electron microscopy, scanning electron microscopy and X-ray diffraction) have been described. Experimentally, the high and low air RH cycling runs have been carried out with a 25 cm2 single cell: the high air RH cycling run promoted serious loss of the ElectroChemical Surface Area (ECSA); the low air RH cycling run caused significant increase in hydrogen crossover. The low air RH cycling has been also performed with a 100 cm2 single cell and the aging mechanism was different from that of 25 cm2 cell: the hydrogen crossover remained very low but the fuel cell voltage exhibited strong fluctuations at the end of the run: this was attributed to the presence of dead volumes and liquid water retention within the cell. Finally, MEA pinhole effect has been investigated with a 100 cm2 single cell: the perforation by a 0.7 mm diameter pin promoted slight increase in the hydrogen crossover; the perforation by a 1.2 mm diameter pin caused significant cell voltage losses and serious increase in the cathode diffusion resistance due to significant hydrogen crossover
52

Acquisition et rendu 3D réaliste à partir de périphériques "grand public" / Capture and Realistic 3D rendering from consumer grade devices

Chakib, Reda 14 December 2018 (has links)
L'imagerie numérique, de la synthèse d'images à la vision par ordinateur est en train de connaître une forte évolution, due entre autres facteurs à la démocratisation et au succès commercial des caméras 3D. Dans le même contexte, l'impression 3D grand public, qui est en train de vivre un essor fulgurant, contribue à la forte demande sur ce type de caméra pour les besoins de la numérisation 3D. L'objectif de cette thèse est d'acquérir et de maîtriser un savoir-faire dans le domaine de la capture/acquisition de modèles 3D en particulier sur l'aspect rendu réaliste. La réalisation d'un scanner 3D à partir d'une caméra RGB-D fait partie de l'objectif. Lors de la phase d'acquisition, en particulier pour un dispositif portable, on est confronté à deux problèmes principaux, le problème lié au référentiel de chaque capture et le rendu final de l'objet reconstruit. / Digital imaging, from the synthesis of images to computer vision isexperiencing a strong evolution, due among other factors to the democratization and commercial success of 3D cameras. In the same context, the consumer 3D printing, which is experiencing a rapid rise, contributes to the strong demand for this type of camera for the needs of 3D scanning. The objective of this thesis is to acquire and master a know-how in the field of the capture / acquisition of 3D models in particular on the rendered aspect. The realization of a 3D scanner from a RGB-D camera is part of the goal. During the acquisition phase, especially for a portable device, there are two main problems, the problem related to the repository of each capture and the final rendering of the reconstructed object.
53

Pozice objektu ze soustavy kamer / Object Position from Multiple Cameras

Dostál, Radek January 2011 (has links)
This thesis deals with reconstruction of golf ball position using multiple cameras. Reconstruction will be used for golf simulator project. System is using fotogrametric calibration and triangulation algorithm for obtaing point coordinates. Work also discuss options for camera selection. The result is making of prototype of the simulator.
54

Určení parametrů pohybu ze snímků kamery / Determination of Motion Parameters in Machine Vision

Dušek, Stanislav January 2009 (has links)
This thesis describe about determination of camera motion parameters in plane. At first there are introduce the basics of motion tracking, is focused to find out displacement between two input images. Below is describe the algorithm GoodFeatruresToTrack, which find out the most significant point in a first image. The point is search out the good point, which will be easy to track in next image, reduce the data volume and prepare the input information (array of significant point) for the algorithm Lucas-Kanade optical flow. In second part is deal with processing and utilization estimations optical flow. There is median filtration, below is describe computation of homogenous transformation, which describe all affine transformation in affine space. As the result are coordinates, which describe the shift between the two input images as X-axis and Y-axis value. The project used the library Open Computer Vision.
55

Promítání kamerou typu "rybí oko" / "Fisheye" Camera Projection

Macík, Pavel January 2008 (has links)
The thesis describes theoretical fundamentals of optics and problems of ray-tracing method, ray-triangle intersection computation included. Next section describes concept of three different camera models for ray-tracing method - plain camera, pinehole camea and spherical camera (fish-eye). The thesis comparse properties and capabilities of camera models and their effect to projected image of a scene. The program for raytracing was implemented for purposes of the thesis including implementation of camera models described in the thesis.
56

Measurement of focal spots of X-ray tubes using a CT reconstruction approach on edge images of holes with a diameter larger than the focal spot and comparison to classical pinhole imaging

Hashemi, Seyedreza 18 July 2024 (has links)
Non-destructive testing (NDT) combines the application of the sciences of phys-ics, mathematics, chemistry, and biology to create a comprehensive process, that can be used for inspection, examination, and testing of materials or components to find flaws, defects or discontinuities at the surface, subsurface areas, or inner volume of the component under test. NDT maintains the serviceability of the component after inspection, without causing any damage to its original form or usefulness. In addition to the need for safety, NDT is used to ensure the efficiency and durability of the equipment. NDT is carried out to ascertain that the compo-nents or materials being used are not damaged or faulty and are fit to be used by any personnel. The result of testing can show whether the components need to be repaired or if they are safe for operation. The first NDT method to evolve in the industrial age was X-ray testing (RT). This innovation was discovered by German physicist Wilhelm Conrad Röntgen in 1895. His experiments involved cathode rays which led to not only the discovery of X-ray but to the first Nobel Prize. Among all NDT methods, RT is no exception, so there are still many issues for optimizations even today. One of them is the measurement of the focal spot of X-ray tubes. The size of the focal spot is critical for imaging because it deter-mines the spatial resolution in the X-ray image. The classical way to image focal spots of X-ray tubes is by pinhole imaging using a camera obscura. This is caused by the fact, that X-ray radiation cannot be imaged by lenses like optical wavelengths. This pinhole imaging has been standardized since a long time, e.g., by EN 12543:1999, ASTM E 1165:1992, IEC 336:1982, and DIN 6823:1962. But this method has a natural lower limit, which is defined by the diameter of the pin-hole (today min. 10 µm). Focal spot sizes lower than this diameter cannot be im-aged and measured correctly. Meanwhile, the development of algorithms of Computed Tomography allows a similar approach for focal spot imaging but using pinholes with a much larger diameter than the focal spot size to be imaged. In such a large hole the edge unsharpness of the hole rim by the focal spot size can be measured in different directions, and a first derivative following a CT recon-struction will deliver a nearly identical focal spot image compared to classical pin-hole imaging. There is principal no lower focal spot size limit anymore. Computa-tional problems must be analyzed and application and parameter range for practi-cal focal spot measurements have to be determined.
57

Quantification 3D d’une surface dynamique par lumière structurée en impulsion nanoseconde. Application à la physique des chocs, du millimètre au décimètre / 3D measurement of a dynamic surface by structured light in nanosecond regime. Application to shock physics, from millimeters to decimeters

Frugier, Pierre Antoine 29 June 2015 (has links)
La technique de reconstruction de forme par lumière structurée (ou projection de motifs) permet d’acquérir la topographie d’une surface objet avec une précision et un échantillonnage de points dense, de manière strictement non invasive. Pour ces raisons, elle fait depuis plusieurs années l’objet d’un fort intérêt. Les travaux présentés ici ont pour objectif d’adapter cette technique aux conditions sévères des expériences de physique des chocs : aspect monocoup, grande brièveté des phénomènes, diversité des échelles d’observation (de quelques millimètres au décimètre). Pour répondre à ces exigences, nous proposons de réaliser un dispositif autour d’un système d’imagerie rapide par éclairage laser nanoseconde, présentant des performances éprouvées et bien adaptées. La première partie des travaux s’intéresse à analyser les phénomènes prépondérants pour la qualité des images. Nous montrons quels sont les contributeurs principaux à la dégradation des signaux, et une technique efficace de lissage du speckle par fibrage est présentée. La deuxième partie donne une formulation projective de la reconstruction de forme ; celle-ci est rigoureuse, ne nécessitant pas de travailler dans l’approximation de faible perspective, ou de contraindre la géométrie de l’instrument. Un protocole d’étalonnage étendant la technique DLT (Direct Linear Transformation) aux systèmes à lumière structurée est proposé. Le modèle permet aussi, pour une expérience donnée, de prédire les performances de l’instrument par l’évaluation a priori des incertitudes de reconstruction. Nous montrons comment elles dépendent des paramètres du positionnement des sous-ensembles et de la forme-même de l’objet. Une démarche d’optimisation de la configuration de l’instrument pour une reconstruction donnée est introduite. La profondeur de champ limitant le champ objet minimal observable, la troisième partie propose de l’étendre par codage pupillaire : une démarche de conception originale est exposée. L’optimisation des composants est réalisée par algorithme génétique, sur la base de critères et de métriques définis dans l’espace de Fourier. Afin d’illustrer les performances de cette approche, un masque binaire annulaire a été conçu, réalisé et testé expérimentalement. Il corrige des défauts de mise au point très significatifs (Ψ≥±40 radians) sans impératif de filtrage de l’image. Nous montrons aussi que ce procédé donne accès à des composants tolérant des défauts de mise au point extrêmes (Ψ≈±100 radians , après filtrage). La dernière partie présente une validation expérimentale de l’instrument dans différents régimes, et à différentes échelles. Il a notamment été mis en œuvre sur l’installation LULI2000, où il a permis de mesurer dynamiquement la déformation et la fragmentation d’un matériau à base de carbone (champs millimétriques). Nous présentons également les mesures obtenues sous sollicitation pyrotechnique sur un revêtement de cuivre cylindrique de dimensions décimétriques. L’apparition et la croissance rapide de déformations radiales submillimétriques est mesurée à la surface du revêtement. / A Structured Light System (SLS) is an efficient means to measure a surface topography, as it features both high accuracy and dense spatial sampling in a strict non-invasive way. For these reasons, it became in the past years a technique of reference. The aim of the PhD is to bring this technique to the field of shock physics. Experiments involving shocks are indeed very specific: they only allow single-shot acquisition of extremely short phenomena occurring under a large range of spatial extensions (from a few mm to decimeters). In order to address these difficulties, we have envisioned the use of a well-known high-speed technique: pulsed laser illumination. The first part of the work deals with the evaluation of the key-parameters that have to be taken into account if one wants to get sharp acquisitions. The extensive study demonstrates that speckle effect and depth of field limitation are of particular importance. In this part, we provide an effective way to smooth speckle in nanosecond regime, leaving 14% of residual contrast. Second part introduces an original projective formulation for object-points reconstruction. This geometric approach is rigorous; it doesn’t involve any weak-perspective assumptions or geometric constraints (like camera-projector crossing of optical axis in object space). From this formulation, a calibration procedure is derived; we demonstrate that calibrating any structured-light system can be done by extending the Direct Linear Transformation (DLT) photogrammetric approach to SLS. Finally, we demonstrate that reconstruction uncertainties can be derived from the proposed model in an a priori manner; the accuracy of the reconstruction depends both on the configuration of the instrument and on the object shape itself. We finally introduce a procedure for optimizing the configuration of the instrument in order to lower the uncertainties for a given object. Since depth of field puts a limitation on the lowest measurable field extension, the third part focuses on extending it through pupil coding. We present an original way of designing phase components, based on criteria and metrics defined in Fourier space. The design of a binary annular phase mask is exhibited theoretically and experimentally. This one tolerates a defocus as high as Ψ≥±40 radians, without the need for image processing. We also demonstrate that masks designed with our method can restore extremely high defoci (Ψ≈±100 radians) after processing, hence extending depth of focus by amounts unseen yet. Finally, the fourth part exhibits experimental measurements obtained with the setup in different high-speed regimes and for different scales. It was embedded on LULI2000 high energy laser facility, and allowed measurements of the deformation and dynamic fragmentation of a sample of carbon. Finally, sub-millimetric deformations measured in ultra-high speed regime, on a cylinder of copper under pyrotechnic solicitation are presented.

Page generated in 0.045 seconds