• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 227
  • 14
  • 7
  • 1
  • 1
  • 1
  • Tagged with
  • 254
  • 172
  • 34
  • 26
  • 23
  • 21
  • 20
  • 19
  • 19
  • 19
  • 19
  • 18
  • 17
  • 17
  • 17
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
221

Optimization and comparison between polymer, surfactant-polymer and water flooding recoveries in a pre-salt carbonate reservoir considering uncertainties. / Otimização e comparação entre recuperação por injeção de polímero, surfactante-polímero e água em reservatório carbonático do pré-sal considerando incertezas.

Garcia Villa, Joan Sebastian 24 April 2019 (has links)
A successful Chemical Enhanced Oil Recovery (CEOR) program starts with a proper process selection for a given field, followed by a formulation of the batch components and a representative simulation step. Also, lab studies, field data, pilot testing, and economic analyses are required before project implementation. This work discusses the state of the art of the Surfactant-Polymer flood (SP) EOR technique, specifically for carbonate reservoirs, and states a methodology mixing laboratory, literature and reservoir simulation, to assess its applicability under economic and geological uncertainties. First, it is explained concepts related to the research, such as polymer, surfactant, microemulsion, functionalities of each chemical injected, advantages, and disadvantages. Second, a state of the art is developed about recent SP advances. Third, it is described the laboratory method being used to evaluate some properties of the chemicals injected for the Polymer flooding (PF) and SP flooding. Later, the simulation study step being conducted is explained, which will define the volume recovered and Net Present Value (NVP) obtained for the PF, SP injections and water flooding, in different economic and geological scenarios for two models resembling carbonate Brazilian reservoirs. Finally, it is discussed the results obtained, future researches that could be performed, and the respective bibliography. As part of this research, it was verified the Xanthan gum shows adequate results at different concentrations; that a surfactant specifically selected for a carbonate rock with low Interfacial tension and low adsorption is required; also that for the Lula based model although the polymer flooding and Surfactant-Polymer simulation brought some benefits, when compared with the waterflooding, on different economic scenarios and geological models, the high cost associated to the chemical handling facilities and volume spent do not make favorable its application in any scenario. On the contrary for the Cerena I field model, it was found the SP and Polymer flooding on all cases brought better results when compared with the water injection. Concluding that the performance and success of a CEOR program require finding the correct slug characteristics for the unique conditions of each reservoir. In this research the reservoir with higher production rates made possible the use of Chemical EOR presenting better results than a water injection however in the smaller model they were not economically viable due to the additional associated prices. / Um programa bem-sucedido de recuperação melhorada de petróleo por método químico (CEOR) começa com uma seleção precisa do processo para um determinado campo, seguido pela formulação dos componentes e uma etapa de formulação representativa. Adicionalmente, testes laboratoriais, dados de campos, testes pilotos e análises econômicas são necessárias antes da implementação de um projeto. Este trabalho discute o estado da arte da técnica de recuperação melhorada de petróleo (EOR) pela injeção de surfactante-polímero (SP), especificamente para reservatórios carbonáticos e, utilizada uma metodologia baseada em dados de laboratório, literatura e de simulação de reservatório para avaliar sua aplicabilidade sob incertezas econômicas e geológicas. Primeiramente, são explicados conceitos necessários a este trabalho relacionados com polímero, surfactante, microemulsão, funcionalidades de cada produto químico injetado, vantagens e desvantagens. Em segundo lugar, um estado da arte é desenvolvido sobre os avanços recentes do SP. Após, descreve-se os métodos laboratoriais utilizados para avaliar algumas propriedades dos produtos químicos usados nas injeções de Polímeros (PF) e SP. Posteriormente, é explicada a etapa do estudo de simulação, que definirá o volume recuperado e o valor presente líquido (NVP), obtidos para injeções PF, SP e água, em diferentes cenários econômicos e geológicos, para dois modelos semelhantes a reservatórios carbonáticos brasileiros. Por fim, são discutidos os resultados obtidos, sugestões de trabalhos futuros e apresentação da bibliografia. Como parte desta pesquisa, verificou-se que a goma xantana apresenta resultados consistentes em diferentes concentrações e que é necessário um surfactante especificamente selecionado para uma rocha carbonática, possuindo baixa tensão interfacial e baixa adsorção. Para o modelo baseado em Lula, embora a simulação de injeção de polímero e surfactante-polímero tenham trazido alguns benefícios, quando comparados com a injeção de água, em diferentes cenários econômicos e modelos geológicos, o alto custo associado às instalações de manipulação química e volume gasto não favorece sua aplicação em qualquer cenário. Por outro lado, no modelo de campo Cerena I, verificou-se que as injeções de SP e de polímero, em todos os casos, trouxeram melhores resultados quando comparadas com a injeção de água. Concluindo, o desempenho e o sucesso de um programa de CEOR exige encontrar as corretas características de slugs para condições únicas de cada reservatório. Neste trabalho, o reservatório com maiores taxas de produção infere que o método químico de EOR apresente melhores resultados quando comparado com a injeção de água.
222

Reforço de ligações viga-pilar de estruturas de concreto pré-moldado pela colagem de laminados de polímero reforçado com fibra de carbono (PRFC) em entalhes no concreto de cobrimento / Strengthening of beam-to-column connections in precast concrete structures by NSM CFRP strips

Fonseca, Tatiana de Cássia Coutinho Silva da 07 February 2013 (has links)
Buscou-se por meio desta pesquisa avaliar a eficiência do reforço de ligações viga-pilar em estruturas de concreto pré-moldado. A técnica de reforço utilizada consiste na colagem de laminados de Polímero Reforçado com Fibra de Carbono (PRFC) em entalhes no concreto de cobrimento. Trata-se de uma técnica desenvolvida há cerca de dez anos, que apresentou, em pesquisas, desempenho superior às alternativas de colagem externa de mantas e laminados no tocante a reforço à flexão. Nenhuma referência ao uso desta ou de qualquer outra técnica para o reforço de ligações viga-pilar de estruturas pré-moldadas foi encontrada na pesquisa bibliográfica realizada. Entretanto, considera-se importante que esta opção seja apreciada ao se verificar comportamento insatisfatório de uma estrutura, haja vista a importância das ligações em seu desempenho global. Dado o caráter da pesquisa e o ineditismo da proposta, realizou-se um estudo experimental diversificado. Um ensaio piloto em modelo reduzido de pórtico com elementos de pilar e viga pré-moldados foi realizado. Por meio deste ensaio, verificou-se que o reforço promoveu significativa redução no deslocamento vertical da viga. Embora os resultados tenham sido promissores, destaca-se que o modelo reduzido impôs limitações, em relação ao comprimento para colagem do laminado e à distância do laminado ao canto da viga, que contribuíram para o seu arrancamento prematuro em uma das ligações. Realizou-se um ensaio em um modelo de ligação em escala real reforçado a momento fletor negativo e positivo. Em relação ao momento negativo, se alcançou um aumento de cerca de 100% na rigidez do modelo. Realizaram-se ensaios experimentais estáticos e dinâmicos em três modelos de pórtico cuja viga tinha escala real. Os resultados destes ensaios comprovaram a eficiência do reforço das ligações no aumento da sua rigidez , da frequência natural do pórtico e da resistência da estrutura. Observou-se também que o reforço promoveu redução da solicitação das armaduras principais da ligação. A simulação numérica dos ensaios dinâmicos permitiu a determinação indireta da rigidez das ligações de modo satisfatório e subsidiou a adoção de apoios elásticos na simulação dos ensaios estáticos que permitiram expandir a análise dos resultados experimentais em relação à fissuração e à distribuição de tensões. Por meio desta pesquisa comprovou-se a possibilidade de emprego da técnica de reforço proposta para a reabilitação de estruturas com deficiência relacionadas ao estado limite ultimo, já que o aumento de resistência foi alcançado, e também relacionadas aos estados limites de serviço, uma vez que as estruturas reforçadas apresentaram menores deslocamentos verticais e maiores frequências naturais. Destaca-se ainda uso eficiente da experimentação dinâmica que se prestou não somente à obtenção dos parâmetros modais da estrutura, mas também a uma avaliação realista das condições de contorno dos ensaios estáticos. / In this research, the strengthening of beam-to-column connections in precast concrete structures is evaluated. The strengthening technique used is internationally known as Near-Surface-Mounted and involves the bonding of CFRP (Carbon Fiber Reinforced Polymer) strips into slits made in concrete cover. There are no references about the use of this or any else technique in the strengthening of connections in precast structures however it could be an option when the structure presents an unsatisfactory behavior. Because of the innovative characteristic of the purpose, experimental tests are required. A pilot test was performed in a frame with reduced dimensions. The frame had initially pinned connections that were strengthened. The strengthening provided a reduction in the beam deflection and the recovery of the initial stiffness of the frame. Although the promising results, the frame dimensions imposed limitations in relation to the strips bonding length and to the distance to the beam edge that contributed to the premature failure by splitting of strips and concrete. It was also performed a test in a strengthened semi-rigid connection. An increase in the connection stiffness was observed. Experimental static and dynamic tests were performed on three real scaled frame models. The results of these tests demonstrated the effectiveness of the strengthening in the increasing of stiffness, natural frequency and strength of the frame. It was also observed that the strengthening reduced the reinforcement strain. The numerical simulation of the dynamic tests allowed the indirect determination of the connections stiffness and supported the definition of boundary conditions in the simulation of the static tests that allowed a better understanding in relation to cracking and stress distribution. Through this research it was confirmed that the strengthening technique proposed is useful for rehabilitation of structures with disabilities related to ultimate limit state, since the increase in resistance was achieved, and also related to the serviceability limit states, since strengthened structures presented lower vertical displacements and higher natural frequencies. It is highlighted that the dynamic tests were important not only to obtain the modal parameters of the structure, but also to evaluate the real boundary conditions of the static tests.
223

Implantação iônica de baixa energia em polímero para desenvolvimento de camadas compósitas nanoestruturadas condutoras litografáveis. / Low energy ion implantation into polymers to develop conductive composite layers for lithography.

Teixeira, Fernanda de Sá 28 June 2010 (has links)
Eletrônica utilizando polímero em substituição ao silício é uma área de pesquisa recente com perspectivas econômicas promissoras. Compósitos de polímeros com partículas metálicas apresentam interessantes propriedades elétricas, magnéticas e ópticas e têm sido produzidos por uma grande variedade de técnicas. Implantação iônica de metais utilizando plasma é um dos métodos utilizados para obtenção desses compósitos condutores. Neste trabalho é realizada implantação de íons de ouro de baixa energia em PMMA utilizando plasma. O PMMA tem grande importância tecnológica sendo largamente utilizado como resiste em litografias por feixe de elétrons, raios-X, íons e deep-UV. Como resultado da implantação iônica de baixa energia em PMMA há formação de uma camada nanométrica de material condutor. Esse novo material, denominado compósito isolante-condutor, permite criar micro e nanodispositivos através de técnicas largamente utilizadas em microeletrônica. Medidas elétricas são realizadas in situ em função da dose de íons metálicos implantada, o que permite um estudo das propriedades de transporte desses novos materiais, que podem ser modeladas pela teoria da percolação. Simulações utilizando o programa TRIDYN permitem obter a profundidade e o perfil da implantação dos íons. São mostradas caracterizações importantes tais como Microscopia Eletrônica de Transmissão, Microscopia de Varredura por Tunelamento, Espalhamento de Raios-X a Baixos Ângulos, Difração de Raios-X e Espectroscopia UV-vis. Essas técnicas permitem visualizar e investigar o caráter nanoestruturado do compósito metal-polímero. Ainda como parte deste projeto, as camadas condutoras formadas no polímero são caracterizadas quanto à manutenção das suas características de elétron resiste. / Electronics using polymers instead of silicon is a recent research area with promising economic perspectives. Polymer with metallic particles composites presents interesting electrical, magnetic and optical properties and they have been produced by a broad variety of techniques. Metal ion implantation using plasma is one of the used methods to obtain conductor composites. In this work it is performed low energy gold ion implantation in PMMA by using plasma. PMMA has great technological importance once it is broadly used as resist in electron-beam, X-ray, ion and deep UV lithography. As a result of low energy ion implantation in PMMA, a nanometric conducting layer is formed. This new material, named insulator-conductor composite, can allow the creation of micro and nanodevices through well known microelectronics techniques. Electrical measurements are performed in situ as a function of metal ions implanted dose, which allows the investigation of electrical transport of these new materials, which can be modeled by the percolation theory. Simulations using TRIDYN computer code provide the prediction of depth profile of implanted ions. Important characterizations are showed such as Transmission Electron Microscopy, Scanning Tunneling Microscopy, Small Angle X-Ray Scattering, X-Ray Diffraction and UV-vis Spectroscopy. These techniques allow to visualize and to investigate the nanostructured character of the metal-polymer composite. Still as a part of this project, the conducting layers formed are characterized in relation to the maintenance of their characteristics as electron-beam resist.
224

Microextração de canabinoides em urina usando dispositivo empacotado com polímero molecularmente impresso e análise por cromatografia líquida - espectrometria de massas sequencial / Microextraction of cannabinoids in urine using device packed with molecularly imprinted polymer and analysis by liquid chromatography - sequential mass spectrometry

Sartore, Douglas Morisue 30 July 2018 (has links)
O preparo da amostra é uma das etapas mais importantes em toda a análise química. O isolamento e a concentração dos componentes da amostra são cruciais e busca-se sempre que essas etapas sejam as mais simples e consumam o mínimo possível de tempo e reagentes. Nos últimos anos, um tipo de material tem se mostrado bastante útil para análises químicas a partir de fluidos biológicos, os polímeros molecularmente impressos (MIPs). Os MIPs são sintetizados por reações de polimerização, na presença de uma molécula molde (template). A molécula molde se liga aos monômeros funcionais do polímero durante a reação de polimerização e permanece ligada à superfície das cadeias poliméricas quando a reação se completa. Terminada a polimerização, realiza-se a completa lavagem das moléculas molde, assim, restam na superfície polimérica cavidades tridimensionais complementares à molécula empregada como molde. Essas cavidades permitem a ligação reversível e preferencial da molécula molde ou outras com estrutura química semelhante. A Cannabis sativa é a droga ilícita mais consumida em todo o mundo e nos últimos anos muita atenção tem se voltado a seus efeitos toxicológicos no corpo humano e a aplicações medicinais. Nesta dissertação, foi sintetizado um MIP com a molécula molde catequina para a extração e posterior análise por LC-MS/MS dos canabinóides Δ9-tetrahidrocanabinol (THC), 11-hidroxi-Δ9-tetrahidrocannabinol (THC-OH) e 11-nor-Δ9-tetrahidrocannabinol-9-ácido carboxílico (THC-COOH) em amostras de urina. O MIP produzido foi empacotado em microdispositivo e empregado no preparo das amostras de urina por microextração por sorvente empacotado (MEPS). O método desenvolvido apresentou boa linearidade (valores de r de 0,977 para o THC e 0,994 para THC-OH e THC-COOH). Os limites de detecção e de quantificação foram respectivamente de 5 ng mL-1 e 20 ng mL-1, para os compostos THC e THC-OH, na faixa linear de 25 a 250 ng mL-1. Para o composto THC-COOH os limites de detecção e quantificação alcançados foram de 1 ng mL-1 e 5 ng mL-1, respectivamente, na faixa linear de 5 a 170 ng mL-1. O método apresentou valores razoáveis de precisão entre 3,2% (THC-COOH) e 25,1% (THC) e de exatidão, que variou entre -18,4 e 17,4 (ambos para o THC). O MIP empregado no preparo da amostra mostrou-se mais seletivo e específico do que materiais normalmente empregados para a extração dos canabinoides das amostras de urina, além de a técnica de extração por MEPS apresentar baixo consumo de solventes e amostra para a extração dos analitos e posterior análise por LC-MS/MS. / The sample preparation is one of the most important steps in every chemical analysis. The isolation and concentration of the sample components are crucial and it is always sought that these steps are simple and consume the lowest amount of time and reagents. In the recent years, a type of material has proved to be very useful for chemical analyzes of biological fluids, the molecularly imprinted polymers (MIPs). MIPs are synthesized by polymerization reactions in the presence of a template molecule. The template molecule binds to the functional monomers of the polymer during the polymerization reaction and remains bonded to the surface of the polymeric chains after the reaction is complete. After the polymerization is finished, the complete washing of the template molecules is carried out, thus, three-dimensional cavities, complementary to the molecule used as a template, remain on the polymer surface. These cavities allow the reversible and preferential bonding of the template molecule or others with similar chemical structure. Cannabis sativa is the most commonly consumed illicit drug in the world and in recent years much attention has focused on its toxicological effects on human body and for medical applications. In this master dissertation, a MIP was synthesized with the catechin molecule as template, for extraction and subsequent analysis by LC-MS/MS of the cannabinoids Δ9-tetrahydrocannabinol (THC), 11-hydroxy-Δ9-tetrahydrocannabinol (THC-OH), and 11-nor-Δ9-tetrahydrocannabinol-9-carboxylic acid (THC-COOH) in urine samples. The MIP produced was packed in a microdevice and used in the preparation of the urine samples by microextraction by packed sorbent (MEPS). The developed method showed good linearity (r values of 0.977 for THC and 0.994 for THC-OH and THC-COOH). The detection and quantification limits were respectively 5 ng mL-1 and 20 ng mL-1 for THC and THC-OH in the linear range from 25 to 250 ng mL-1. For the compound THC-COOH the limits of detection and quantification achieved were 1 ng mL-1 and 5 ng mL-1, respectively, in the linear range from 5 to 170 ng mL-1. The method presented reasonable values of precision, between 3.2% (for THC-COOH) and 25.1% (for THC) and displayed accuracy ranging from -18.4 to 17.4 (both for THC). The MIP used in the sample preparation was more selective and specific than other materials usually employed for the extraction of the cannabinoids from the urine samples. The MEPS technique also showed low consumption of solvents and sample for sample preparation, extraction of analytes and subsequent analysis by LC-MS/MS.
225

Emprego de coagulante à base de tanino em sistema de pós-tratamento de efluente de reator UASB por flotação / Use of tannin-based coagulant in exhaust post-treatment of UASB reactor effluent by flotation

Pelegrino, Eloá Cristina Figueirinha 03 June 2011 (has links)
O presente trabalho teve como objetivo principal a avaliação da eficiência de remoção de carga orgânica, fósforo e sólidos em suspensão de sistema de flotação tratando esgoto sanitário pré-tratado em reatores UASB, da ETE Monjolinho da cidade de São Carlos/SP, e coagulado com tanino associado ou não a polímeros sintéticos. Os ensaios com variação de dosagem de coagulante Tanino e polímeros (polímero catiônico, polímero não-iônico e polímero aniônico) foram realizados em escala de laboratório, com o uso do equipamento flotateste. Em todos os ensaios foram fixados os valores de gradiente de velocidade na mistura rápida (800/s) e na floculação (90/s), ao tempos de detenção na mistura rápida (20 s) e na floculação (15 min) e, a pressão de saturação 5 Bar e a razão de recirculação (17%). Durante os ensaios com unidade de flotação em escala de bancada foram avaliados três valores de velocidades de flotação: 12,0 cm/min, 16,0 cm/min e 20,0 cm/min. Os ensaios foram divididos em duas fases: a fase 1 teve como objetivo analisar a resposta do sistema de flotação com o emprego do coagulante Tanino no tratamento do efluente do reator UASB da ETE Monjolinho (fase 1A) e também determinar as duas dosagens do coagulante Tanino mais adequadas para o tratamento do efluente de UASB da ETE Monjolinho para cada polímero testado (fase 1B). As fases 1A e 1B foram realizadas com efluente coletado às 8:00 h e 14:00 h, respectivamente. A fase 2 teve como objetivo a busca da dosagem ótima de tanino dentro de uma faixa mais estreita de valores, assim como a verificação do melhor tipo e dosagem de polímero sintético (não-iônico, aniônico e catiônico) para ser associado ao coagulante tanino. Na fase 1A, verificou-se que a flotação foi efetiva para remoção de cor aparente mesmo para dosagem nula de coagulante Tanino. Quanto à turbidez, verificou-se efeito marcante da adição de dosagem crescente de coagulante no aumento da eficiência de remoção desse parâmetro. Após a obtenção dos resultados da fase 1B, foram escolhidas para a fase 2 as duas menores dosagens de coagulante capazes de promover redução da turbidez em pelo menos 85%. Além destas duas dosagens, foram avaliados na fase 2 outras 3 dosagens compreendidas entre elas. Sendo assim, na fase 2 foram estudadas as doses de 65, 75, 85, 95 e 105 mg/L de coagulante, cada qual associada a seis dosagens de cada um dos polímeros estudados. Entre os tratamentos empregados, pôde-se verificar maior eficácia do polímero não-iônico e do polímero catiônico para o tratamento por flotação, associado ao coagulante tanino. O conjunto de dosagem de coagulante tanino e polímero mais vantajoso, ou seja, menor dosagem de tanino que, associada a polímero, apresentou remoção satisfatória dos parâmetros estudados, foi 65 mg/L de Tanino e 2,0 mg/L de polímero catiônico, atingindo remoções de 95,2% de turbidez (Residual de 3,65 NTU), 82,1% de cor aparente (Residual de 98 mgPT/L), 49,2% de fósforo total (Residual de 3,2 mg/L), 80,7% de DQO (Residual de 25 mg/L) e 87,9 % de SST (Residual de 13 mg/L) nas condições encontradas na época dos ensaios, para o pós-tratamento por flotação de efluente de reator UASB da ETE Monjolinho, São Carlos/SP. / The main objective of this work is the evaluation of the efficiency of removal of organic load, phosphorus and suspended solids in the flotation system treating domestic wastewater pretreated in UASB reactors, of the Monjolinho Wastewater Treatment Plant (WWTP) of Sao Carlos, SP and clotted with tannin alone or combined with synthetic polymers. Tests varying tannin dosage of coagulant and polymer (cationic polymer, nonionic polymer and anionic polymer) were performed on a batch scale, using flotatest. In all the tests were fixed the values of rapid mix (800/s) and flocculation (90/s) velocity gradients, the rapid mix (20 s) and flocculation (15 min) times, saturation pressure (5 Bar) and recycle rate (17%). During the test in the flotation bench scale unity three values of flotation velocities were evaluated: 12.0 cm/min, 16.0 cm/min and 20.0 cm/min. The tests were divided in two phases: the objective of phase 1 was to examine the response of the flotation system with the use of tannin coagulant in the treatment of Monjolinho WWTP UASB effluent (Phase 1A) and also determine the two most suitable dosages of tannin coagulant for the treatment of wastewater from the Monjolinho WWTP UASB tested for each polymer (phase 1B). Phases 1A and 1B were performed with wastewater collected at 8:00 h and 14:00 h, respectively. The objective of phase 2 was to find the optimum dosage of tannin within a narrower range of values, as well as verification of the optimal type and dosage of synthetic polymer (non-ionic, anionic and cationic) to be associated with the tannin coagulant. In phase 1A, it was found that flotation was effective for apparent color removal even to zero coagulant dosage tannin. As for turbidity, there is a marked effect when increasing the coagulant dose, which increased the removal efficiency of this parameter. After obtaining the results of Phase 1B, were chosen for phase 2 two low coagulant dosages which can promote reduction of turbidity by 85%. Besides the two dosages obtained in phase 1B, in phase 2 were evaluated other three between them. Thus, in phase 2 were studied coagulant doses of 65, 75, 85, 95 and 105 mg/L, each one associated with six doses of each one of the studied polymers. Among the treatments employed, it could be seen that the non-ionic polymer and the cationic polymer were the most efficient for treatment by coagulation associated with tannin in flotation. The set of tannin coagulant dosage and polymer which showed satisfactory removal of parameters was 65 mg/L of Tannin with 2.0 mg/L of cationic polymer, reaching 95.2% removal of turbidity, 83% of color apparent, 49.2% of total phosphorus, COD 80.7% and 87.9% of TSS under the conditions found at the time of testing, for post-treatment of Monjolinho WWTP UASB effluent by flotation.
226

Investigação da relação entre parâmetros da compactação giratória e de deformação permanente em misturas asfálticas densas / Investigation of relationship between the gyratory compaction and rutting parameters of asphalt mixtures

Soares, Jéssica Santiago 08 August 2014 (has links)
Esta pesquisa tem como objetivo estudar a relação entre parâmetros de compactação e de deformação permanente à luz dos ensaios de compactação giratória Superpave ® e de ensaios de compressão uniaxial estática e dinâmica. Foram estudadas 8 misturas asfálticas com a mesma granulometria (Faixa C) e tipo de agregado mineral (granito) porém variou-se o ligante asfáltico (CAP 50/70 e CAP 50/70+SBS), o volume de vazios (4% e 7%) e a adição de cal hidratada. A partir dos resultados do ensaio de compactação observou-se que a inclinação das curvas de compactação das misturas compactadas a 7% foram mais acentuadas do que as de 4% e os parâmetros incidentais deste ensaio foram sensíveis à presença de cal e à variação do asfalto das misturas testadas. Quanto aos resultados dos ensaios de creep estático e dinâmico, notou-se que as misturas com Vv de 4% e as com asfalto modificado apresentam menor suscetibilidade à deformação permanente, no entanto, essas vantagens do asfalto modificado foram observadas somente nos ensaios de creep dinâmico. No que se refere às relações entre os parâmetros de compactação e de deformação permanente, os ajuste não se mostraram promissores como verificado pela qualidade dos ajustes (R2) exceto para algumas relações com CDI e TDIm. / This research aims to study relations between compaction and permanent deformation by means of Superpave® gyratory compaction and static and dynamic creep tests. Thus, eight asphalt mixtures were evaluated which were composed by same type (granite) and gradation (dense) of mineral aggregate but two types of asphalt binder (Pen 50/70 AC and Pen 50/70+SBS AC), two different levels of air voids (4% and 7%) and the addition of hydrated lime. Compaction results indicated that curve slopes of 7% air void asphalt mixtures were stronger than the 4% ones, and compaction parameters were sensitive to lime addition and asphalt type change. Static and dynamic creep test results indicated that 4% air void and modified asphalt mixtures presented lower susceptibility to rutting, but, these modified asphalt advantages were observed only in dynamic creep tests. In regard to relation between compaction and rutting parameters, linear models did not fit accurately, excepting some CDI and TDIm ones.
227

Eletrólitos poliméricos a partir de poli(vinil butirato) para dispositivos eletrocrômicos e células solares / Polymer electrolytes from Polyvinyl butyrate for electrochromic devices and solar cells

Mota, Lucas Ponez da 27 April 2016 (has links)
O presente trabalho visou preparar e caracterizar eletrólitos poliméricos (EP) à base de poli(vinil butirato) (PVB) com diferentes sais de lítio (LiClO4, LiCF3SO3 e LiI/I2), com ou sem o plastificante g-butirolactona (GBL), além de viabilizar a aplicação dos mesmos em dispositivos eletrocrômicos e células solares. Observou-se, através das análises por espectroscopia de impedância eletroquímica, que o PVB é capaz de solvatar no máximo 40% de sal de lítio em massa. Foi verificado que as condutividades iônicas dessas amostras, em função do aumento da temperatura, podem ser explicadas pelo modelo Vogel-Tammann-Fulcher, e que o eletrólito PF04 (PVB com 40% de LiCF3SO3) possui o maior valor de condutividade (1,5´10-4 S/cm) com relação às outras amostras. Os espectros de infravermelho das amostras estudadas mostraram um deslocamento nos picos correspondentes às carbonilas da matriz polimérica em resposta à coordenação das mesmas com íons Li+. Os resultados da espectroscopia Raman comprovaram a presença do par redox (I3-/I-) no eletrólito com LiI/I2. Os difratogramas de raios-X do PVB evidenciaram um pico largo centrado em 20º (2q) com 800 c.p.s. de intensidade, a adição de LiI/I2 e LiCF3SO3 ao polímero reduziu as intensidades para 750 e 700 c.p.s respectivamente, ao contrário do observado com LiClO4, onde se nota que o sal não foi completamente solvatado pelo polímero. A micrografia obtida por microscopia eletrônica de varredura (SEM) do eletrólito com 23% de LiClO4 (amostra P04) mostraram evidências de aglomerados iônicos na superfície. As análises por calorimetria exploratória diferencial (DSC) mostraram que um aumento na concentração de sal adicionado ao polímero causou uma diminuição na temperatura de transição vítrea (Tg), e que os eletrólitos possuem em torno de 44% de cristalinidade. Os eletrólitos P04 e PF04 foram aplicados em janelas eletrocrômicas, apresentando uma diferença de 10,5 e 9,3% respectivamente entre os estados colorido e descolorido. O eletrólito com LiI/I2 foi aplicado em célula solar gerando uma fotocorrente máxima de 1,09 mA/cm2 e eficiência de 0,41% sob a irradiação de 100 mW/cm2. Eletrólitos géis com adição de 90% γ-butirolactona também foram aplicados em células solares, os valores de fotocorrente e eficiência foram incrementados (5,82 mA/cm2 e 2,1%, respectivamente). / The aim of the present study was to prepare and characterize polymer electrolytes (EP) based on poly(vinyl butyrate) (PVB) with different lithium salts (LiClO4, LiCF3SO3 and LiI/I2) and/or containing g-butyrolactone (GBL), and to apply them in electrochromic devices and solar cells. It was observed through electrochemical impedance spectroscopy that the PVB is able to solvate up to 40% in weight of lithium salt. It was found that the ionic conductivity of these samples, as a function of temperature, can be explained by Vogel-Tammann-Fulcher model, and the electrolyte PF04 (PVB with 40% of LiCF3SO3) had the highest conductivity value of 1,5´10-4 S/cm when compared to other samples. Infrared spectra of the samples showed a shift in the peaks corresponding to the carbonyl groups of the polymer matrix in response to their coordination with Li+ ions. The results of Raman spectroscopy confirmed the presence of the redox couple (I3-/I-) in the electrolyte with LiI/I2 (PVB04). The X-ray diffractograms of the PVB showed a broad peak centered at 20 (2q) com intensity of 800 cps. The addition of LiI/I2 and LiCF3SO3 to the polymer matrix decreased the intensities to 750 and 700 cps respectively, but not after the LiClO4 addition, which was explained by its not complete solvatation by the polymer matrix. The Scanning Electron Microscopy (SEM) pictures of electrolyte with 23% of LiClO4 (P04 sample) showed evidences of ion clusters on the surface. The analyzes via Differential Scanning Calorimetry (DSC) showed that an increase in the concentration of the salt added to the polymer matrix caused a decrease in glass transition temperature (Tg), and that electrolytes are about 44% crystalline. The electrolytes P04 and PF04 were applied to electrochromic windows (ECDs) and showed a transmittance difference of 10.5 and 9.3%, respectively between the colored and discolored states. The electrolyte with LiI/I2 was applied to dye sensitized solar cell (DSSC) generating a maximum photocurrent of 1.09 mA/cm2 and 0.41% of efficiency under irradiation of 100 mW/cm2. Gel electrolytes containing 90% of γ-butyrolactone were applied to DSSC and showed 5.82 mA/cm2 of photocurrent and 2.1% of efficiency.
228

Comportamento de filtros rápidos de camada profunda no tratamento de águas de abastecimento mediante o emprego de polímeros como auxiliares de filtração. / Behavior of deep bed rapid filters treating public water supplies through the use of polymers as filter aids.

Abreu, Sergio Brasil 26 June 2009 (has links)
O projeto consistiu em avaliar o emprego de polímeros catiônicos e aniônicos de diferentes pesos moleculares como auxiliares de filtração no tratamento de águas de abastecimento proveniente de mananciais com alto grau de eutrofização com vistas a possibilitar a otimização da remoção de material particulado e minimização da evolução da perda de carga. O aparato experimental é composto, principalmente, por 4 filtros em escala piloto de alta taxa do tipo camada profunda e fluxo descendente por gravidade operados em paralelo. Os filtros possuem 5 m de altura e diâmetro interno de 150 mm. O procedimento experimental foi dividido em três etapas, execução de ensaios de fluidificação e expansão do leito dos filtros e utilização de polímeros catiônicos e de polímero aniônico como auxiliares de filtração. A primeira etapa teve como objetivo definir parâmetros de dimensionamento do sistema de lavagem em contra-corrente com ar e água e nas duas etapas seguintes foram realizados os ensaios de filtração a uma taxa de 500 m³/m²/dia, com a utilização dos polímeros com três dosagens diferentes. Os polímeros utilizados foram CA-2577, CA-2581, CD-2592 e N1986. Estes possuem estrutura e pesos moleculares variáveis, de forma que o trabalho tivesse uma maior amplitude. Os valores médios de turbidez, para a primeira etapa dos ensaios de filtração, foram de 2,36 ± 0,28 UNT e 1,12 ± 0,21 UNT para água bruta e decantada, respectivamente, 0,26 ± 0,07 UNT para o filtro F1 com antracito, 0,25 ± 0,08 UNT para o filtro F3 com antracito e adição de polímero, 0,29 ± 0,08 UNT para o filtro F2 com areia e 0,26 ± 0,08 UNT para o filtro F4 com areia e adição de polímero. Para a segunda etapa dos ensaios de filtração os valores médios de turbidez foram de 2,03 ± 0,36 UNT para água bruta, 0,80 ± 0,21 UNT para água decantada, 0,09 ± 0,03 UNT para o filtro F1, sem adição de polímero, e 0,15 ± 0,04, 0,16 ± 0,03 e 0,10 ± 0,04 UNT para os filtros F2, F3 e F4, respectivamente, todos com adição de polímero. Os resultados experimentais possibilitaram concluir que a adoção do antracito como material filtrante do tipo camada única e profunda apresenta a vantagem de permitir uma menor velocidade ascensional de água de lavagem para uma determinada expansão quando comparado a um filtro de areia de idêntica granulometria. A aplicação dos polímeros catiônicos e do polímero aniônico como auxiliares de filtração não proporcionou para nenhuma dosagem utilizada melhora significativa no comportamento dos filtros. Uma eventual melhora ou piora foi insignificante e estava ligada à qualidade da água decantada. No que diz respeito à perda de carga, os filtros com antracito tiveram carreiras de filtração mais longas quando comparados com os de areia, independente da utilização dos polímeros. / The project was to evaluate the use of anionic and cationic polymers of different molecular weights as filter aids to treat drinking water treatment of surface water sources with high degree of eutrophication, particularly with regard to particulate matter removal optimization and head loss rate minimization. The experimental apparatus was composed of four pilot scale, deep bed, down flow rapid gravity filters, operated in parallel. The filter columns were 5 m high, had inner diameter of 150 mm. The experimental procedure was divided in three stages, conduction of media fluidization and media expansion tests and cationic and anionic polymers application as filter aid. The first stage aims was to define design parameters for the filter backwashing system with water and air and in the two next phases the tests were conducted at a filtration rate of 500 m³/m²/day, with the use of polymers with three different dosages. The polymers tested were CA- 2577, CA-2581, CD-2592 and N1986. They have different structure and molecular weights, thus making wider the array of possibilities tested. The average values of turbidity, for the first stage of testing filtration, were 2.36 ± 0.28 and 1.12 ± 0.21 NTU for raw and settled water, respectively, 0.26 ± 0.07 NTU to the filter F1 with anthracite, 0.25 ± 0.08 NTU for the filter F3 with anthracite and addition of polymer, 0.29 ± 0.08 NTU for the filter F2 with sand and 0.26 ± 0.08 NTU for the filter F4 with sand and the addition of polymer. For the second stage of testing of the filter values of turbidity were 2.03 ± 0.36 NTU for raw water, 0.80 ± 0.21 NTU for settled water, 0.09 ± 0.03 for the filter F1, without the addition of polymer, and 0.15 ± 0.04, 0.16 ± 0.03 and 0.10 ± 0.04 NTU for filters F2, F3 and F4, respectively, all with the addition of polymer. The experimental results led us to conclusion that the adoption of anthracite as single media in deep bed filtration presents the advantage of a lower ascent backwash water velocity for any given bed expansion as compared to deep bed filtration through sand with the same granulometric characteristic. Application of cationic and anionic polymers as filter aids did not lead to any significant improvement in the behavior of pilot scale filters, regardless of applied polymer dosage. Any eventual improvement or worsening was not significant and was closely related to the settled water quality. Regarding the head loss, the filters with anthracite had longer filtration careers when compared to sand, regardless the use of polymers.
229

Implantação iônica de baixa energia em polímero para desenvolvimento de camadas compósitas nanoestruturadas condutoras litografáveis. / Low energy ion implantation into polymers to develop conductive composite layers for lithography.

Fernanda de Sá Teixeira 28 June 2010 (has links)
Eletrônica utilizando polímero em substituição ao silício é uma área de pesquisa recente com perspectivas econômicas promissoras. Compósitos de polímeros com partículas metálicas apresentam interessantes propriedades elétricas, magnéticas e ópticas e têm sido produzidos por uma grande variedade de técnicas. Implantação iônica de metais utilizando plasma é um dos métodos utilizados para obtenção desses compósitos condutores. Neste trabalho é realizada implantação de íons de ouro de baixa energia em PMMA utilizando plasma. O PMMA tem grande importância tecnológica sendo largamente utilizado como resiste em litografias por feixe de elétrons, raios-X, íons e deep-UV. Como resultado da implantação iônica de baixa energia em PMMA há formação de uma camada nanométrica de material condutor. Esse novo material, denominado compósito isolante-condutor, permite criar micro e nanodispositivos através de técnicas largamente utilizadas em microeletrônica. Medidas elétricas são realizadas in situ em função da dose de íons metálicos implantada, o que permite um estudo das propriedades de transporte desses novos materiais, que podem ser modeladas pela teoria da percolação. Simulações utilizando o programa TRIDYN permitem obter a profundidade e o perfil da implantação dos íons. São mostradas caracterizações importantes tais como Microscopia Eletrônica de Transmissão, Microscopia de Varredura por Tunelamento, Espalhamento de Raios-X a Baixos Ângulos, Difração de Raios-X e Espectroscopia UV-vis. Essas técnicas permitem visualizar e investigar o caráter nanoestruturado do compósito metal-polímero. Ainda como parte deste projeto, as camadas condutoras formadas no polímero são caracterizadas quanto à manutenção das suas características de elétron resiste. / Electronics using polymers instead of silicon is a recent research area with promising economic perspectives. Polymer with metallic particles composites presents interesting electrical, magnetic and optical properties and they have been produced by a broad variety of techniques. Metal ion implantation using plasma is one of the used methods to obtain conductor composites. In this work it is performed low energy gold ion implantation in PMMA by using plasma. PMMA has great technological importance once it is broadly used as resist in electron-beam, X-ray, ion and deep UV lithography. As a result of low energy ion implantation in PMMA, a nanometric conducting layer is formed. This new material, named insulator-conductor composite, can allow the creation of micro and nanodevices through well known microelectronics techniques. Electrical measurements are performed in situ as a function of metal ions implanted dose, which allows the investigation of electrical transport of these new materials, which can be modeled by the percolation theory. Simulations using TRIDYN computer code provide the prediction of depth profile of implanted ions. Important characterizations are showed such as Transmission Electron Microscopy, Scanning Tunneling Microscopy, Small Angle X-Ray Scattering, X-Ray Diffraction and UV-vis Spectroscopy. These techniques allow to visualize and to investigate the nanostructured character of the metal-polymer composite. Still as a part of this project, the conducting layers formed are characterized in relation to the maintenance of their characteristics as electron-beam resist.
230

Caracterização de agregados supramoleculares: interação de vesículas de Doda com polimetacrilato (OU) Caracterização de agregados supramoleculares: interação de vesículas de dioctadecildimetilamônio com polimetacrilato / Characterisation of supramolecular aggregates: interaction of dioctadecyldimethylammonium vesicles with polymethacrylate

Silva, Idélcio Nogueira da 15 April 2002 (has links)
Este trabalho teve como objetivo estudar a interação de polimetacrilato com vesículas de metacrilato de dioctadecildimetílamônio (DODAM) e brometo de dioctadecildimetilamônio (DODAB). A fotoirradiação de vesículas de DODAM a formou polimetacrilato na superfície vesicular do polímero, através da polimerização do contra-íon. Vesículas polimerizadas foram mais estáveis frenta á adição de metanol do que vesículas não polimerizadas. A estabilização da bicamada vesicular foi confirmada com o aumento da retenção da carboxifluoresceína (CF). Vesículas injetadas de DODAM retiveram cerca de 25% de CF, enquanto que vesículas polimerizadas retiveram cerca de 75%. Experimentos de temperatura de transição de fase por turbidez e tensão superfícial mostraram que o polimetacrilato formado na superfície vesicular diminui a temperatura de transição de fase e reduz a cooperatividade. A interação de fosfatase alcalina (Fal) com vesículas de DODAM e colinametacrilato de dicetilfosfato (DCM) foi estudada, como um primeiro passo para a construção de um micro-reator. Foi observada a precipitação na presença de DODAM, mas não em presença de DCM. Isto pode ser explicado pela forte interação entre a superfície de vesículas de dioctadecildimetilamônio (bicamada com carga negativa) com a fosfatase alcalina (carga negativa). Esta precipitação não foi observada com vesículas de DCM (bicamada negativa). Experimentos de monocamada confirmaram estes resultados. DCM e DODAM formaram monocamadas mistas estáveis, sugerindo que vesículas mistas poderiam ser usadas para superar as interações eletrostáticas fortes entre os surfactantes e a enzima. / This work had as objective studying the interaction of polymethacrylate with dioctadecyldimethylammonium methacrylate (DODAM) and brornide (DODAB). The fotoirradiation of vesicular suspensions of DODAM formed polymethacrylate on the vesicle surface though counter-ion polymerization. Polymerized vesicles were more stables on methanol addition than non-polymerized vesicles. Bilayer stability was confirmed with the retention of carboxyfluorescein (CF). DODAM injected vesicles without polymerization retained about 25% of CF, while polymerized DODAM retained about 75%. Experiments of phase transition temperature by turbidity and surface tension showed that polymethacrylate formed at vesicle surface drops phase transition temperature and reduces cooperativity. Polymethacrylic acid and polymethacrylic acid containing rodhamine B covalently linked was used to monitor polymer-vesicle interaction. Experiments showed that the polymer interacts electrostatically with the DODAB bilayer, causing precipitation and or aggregation. The polymer, initially on a confonnation with many hipercoiled hydrophobic regions, opens as interacts with DODAB vesicles. The interaction of alkaline phosphatase (Fal) with vesicles of DODAM and colina-methacrylate dicetylphosphate (DCM) was studied, as a preliminary step for a micro-reactor construction. Precipitation was observed in presence of DODAM, but not in presence of DCM. This may be explained by the strong interaction between the surface of dioctadecyldimethy lammonium vesicles (positive charged bylayer) with Fal (negative charge). This precipitation was not observed with DCM vesicles (negative charged bilayer). Monolayer experiments confirm these results. Experiments showed that DCM and DODAM form stabled mixed monolayers. Suggesting that mixed vesicles could be tried to overcome strong electrostatic interactions between surfactants and enzyme.

Page generated in 0.0479 seconds