• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 66
  • 31
  • 21
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • Tagged with
  • 177
  • 177
  • 95
  • 93
  • 45
  • 36
  • 32
  • 32
  • 23
  • 22
  • 19
  • 19
  • 18
  • 18
  • 17
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
171

Contribution for integrating urban wind turbine into electrical microgrid : modeling and control / Contribution à l'intégration des éoliennes urbaines dans un micro réseau électrique : modélisation et contrôle

Liu, Hongliang 27 January 2017 (has links)
L’intégration de l’énergie éolienne, qui est une ressource renouvelable très utilisée, n’est pas toujours facile pour le micro-réseau urbain. Dans cette thèse, une éolienne urbaine basée sur une machine synchrone à aimants permanents (MSAP) est étudiée pour être intégrée dans un micro-réseau urbain à courant continu. Un état de l'art concernant les énergies renouvelables, les micro-réseaux à courant continu et les stratégies de contrôle de la production d'énergie éolienne, est réalisée. Basé sur un modèle d’éolienne urbaine répondant à la demande du système électrique, qui se compose d’un émulateur de vent et de pales, un MSAP et un convertisseur DC/DC, cette thèse propose des méthodes de poursuite du point de puissance maximale satisfaisant à l’obligation de produire de l’énergie dans la mesure du possible. Une stratégie de contrôle à puissance limitée répond correctement. De simples à complexes, quatre algorithmes MPPT, P&O à pas fixe, P&O à pas variable avec la méthode Newton-Raphson améliorée, P&O à pas variable à base de logique floue et une méthode indirecte de type lookup table, sont étudiés et implémentés pour être comparés à l’aide de trois profils de vitesse du vent. Par expérimentation, les algorithmes MPPT et PLC sont comparés, analysés et discutés. Résumant tous les résultats expérimentaux, la méthode lookup table peut gérer toutes les exigences du mode de fonctionnement MPPT en présentant la meilleure performance, mais, dans le mode de fonctionnement PLC, la P&O à base de logique floue présente les meilleures performances. / The integration of the wind power, which is one mostly used renewable resource, is always one challenger for urban microgrid. In this thesis, one urban wind turbine based on a permanent magnet synchronous machine (PMSM) is studied in order to be integrated into a DC urban microgrid. A state of the art concerning the renewable energies, DC microgrid, and control strategies of wind power generation is done. Based on a model of urban wind turbine fitting the demand of urban electric system, which consists of an emulator of wind speed and blades, a PMSM and a DC/DC converter, this thesis proposes the maximum power point tracking (MPPT) methods satisfying the requirement of producing energy as much as possible, and power limited control (PLC) strategies answering the demand of flexible energy production. From simple to complex, four MPPT algorithms including Perturbation and Observation (P&O) fixed step-size method, P&O with improved Newton-Raphson method, P&O with fuzzy logic method and lookup table method are studied and implemented to be compared with each other using three wind velocity profiles. According to the experience about MPPT subject, four PLC algorithms are introduced and implemented to be analyzed and compared with each other with one power demand profile calculated randomly. Summarizing all experimental results, the lookup table method can handle all requirement of MPPT operating mode supplying the best performance, however, in the condition of more flexible power demand operating mode, the combination of P&O and fuzzy logic method presents the best performance and potential which can be achieved in future works.
172

Modeling and control of hydraulic wind power transfer systems

Vaezi, Masoud January 2014 (has links)
Indiana University-Purdue University Indianapolis (IUPUI) / Hydraulic wind power transfer systems deliver the captured energy by the blades to the generators differently. In the conventional systems this task is carried out by a gearbox or an intermediate medium. New generation of wind power systems transfer the captured energy by means of high-pressure hydraulic fluids. A hydraulic pump is connected to the blades shaft at a high distance from the ground, in nacelle, to pressurize a hydraulic flow down to ground level equipment through hoses. Multiple wind turbines can also pressurize a flow sending to a single hose toward the generator. The pressurized flow carries a large amount of energy which will be transferred to the mechanical energy by a hydraulic motor. Finally, a generator is connected to the hydraulic motor to generate electrical power. This hydraulic system runs under two main disturbances, wind speed fluctuations and load variations. Intermittent nature of the wind applies a fluctuating torque on the hydraulic pump shaft. Also, variations of the consumed electrical power by the grid cause a considerable load disturbance on the system. This thesis studies the hydraulic wind power transfer systems. To get a better understanding, a mathematical model of the system is developed and studied utilizing the governing equations for every single hydraulic component in the system. The mathematical model embodies nonlinearities which are inherited from the hydraulic components such as check valves, proportional valves, pressure relief valves, etc. An experimental prototype of the hydraulic wind power transfer systems is designed and implemented to study the dynamic behavior and operation of the system. The provided nonlinear mathematical model is then validated by experimental result from the prototype. Moreover, this thesis develops a control system for the hydraulic wind power transfer systems. To maintain a fixed frequency electrical voltage by the system, the generator should remain at a constant rotational speed. The fluctuating wind speed from the upstream, and the load variations from the downstream apply considerable disturbances on the system. A controller is designed and implemented to regulate the flow in the proportional valve and as a consequence the generator maintains its constant speed compensating for load and wind turbine disturbances. The control system is applied to the mathematical model as well as the experimental prototype by utilizing MATLAB/Simulink and dSPACE 1104 fast prototyping hardware and the results are compared.
173

The nature of services provided to adult female survivors of abuse at the Lenasia police station

Mitchell, Chanaz Anzolette 30 November 2003 (has links)
The research addresses secondary victimization of women reporting abuse at the Lenasia Police Station and reasons why it occurs. In addition, the research also determines if the expectations of the survivors of abuse about the police when reporting abuse are in line with what the Domestic Violence Act stipulates as their duties. To determine this, a sample of survivors reporting abuse was used. A qualitative and quantitative approach to the research was used. Two questionnaires were used for the sample of survivors and for service provides, with an opinion survey with knowledgeable people and a focus group discussion with police. It was found that some women were experiencing victimization by the police and that the survivors' expectations of the police were as stipulated in the Domestic Violence Act. Services provided by service providers were outlined and obstacles preventing police to provide a good service were identified. Recommendations were made. / Social work / MA(SS) (SOCIAL WORK)
174

Control of transmission system power flows

Kreikebaum, Frank Karl 13 January 2014 (has links)
Power flow (PF) control can increase the utilization of the transmission system and connect lower cost generation with load. While PF controllers have demonstrated the ability to realize dynamic PF control for more than 25 years, PF control has been sparsely implemented. This research re-examines PF control in light of the recent development of fractionally-rated PF controllers and the incremental power flow (IPF) control concept. IPF control is the transfer of an incremental quantity of power from a specified source bus to specified destination bus along a specified path without influencing power flows on circuits outside of the path. The objectives of the research are to develop power system operation and planning methods compatible with IPF control, test the technical viability of IPF control, develop transmission planning frameworks leveraging PF and IPF control, develop power system operation and planning tools compatible with PF control, and quantify the impacts of PF and IPF control on multi-decade transmission planning. The results suggest that planning and operation of the power system are feasible with PF controllers and may lead to cost savings. The proposed planning frameworks may incent transmission investment and be compatible with the existing transmission planning process. If the results of the planning tool demonstration scale to the national level, the annual savings in electricity expenditures would be $13 billion per year (2010$). The proposed incremental packetized energy concept may facilitate a reduction in the environmental impact of energy consumption and lead to additional cost savings.
175

The nature of services provided to adult female survivors of abuse at the Lenasia police station

Mitchell, Chanaz Anzolette 30 November 2003 (has links)
The research addresses secondary victimization of women reporting abuse at the Lenasia Police Station and reasons why it occurs. In addition, the research also determines if the expectations of the survivors of abuse about the police when reporting abuse are in line with what the Domestic Violence Act stipulates as their duties. To determine this, a sample of survivors reporting abuse was used. A qualitative and quantitative approach to the research was used. Two questionnaires were used for the sample of survivors and for service provides, with an opinion survey with knowledgeable people and a focus group discussion with police. It was found that some women were experiencing victimization by the police and that the survivors' expectations of the police were as stipulated in the Domestic Violence Act. Services provided by service providers were outlined and obstacles preventing police to provide a good service were identified. Recommendations were made. / Social work / MA(SS) (SOCIAL WORK)
176

PV Based Converter with Integrated Battery Charger for DC Micro-Grid Applications

Salve, Rima January 2014 (has links)
Indiana University-Purdue University Indianapolis (IUPUI) / This thesis presents a converter topology for photovoltaic panels. This topology minimizes the number of switching devices used, thereby reducing power losses that arise from high frequency switching operations. The control strategy is implemented using a simple micro-controller that implements the proportional plus integral control. All the control loops are closed feedback loops hence minimizing error instantaneously and adjusting efficiently to system variations. The energy management between three components, namely, the photovoltaic panel, a battery and a DC link for a microgrid, is shown distributed over three modes. These modes are dependent on the irradiance from the sunlight. All three modes are simulated. The maximum power point tracking of the system plays a crucial role in this configuration, as it is one of the main challenges tackled by the control system. Various methods of MPPT are discussed, and the Perturb and Observe method is employed and is described in detail. Experimental results are shown for the maximum power point tracking of this system with a scaled down version of the panel's actual capability.
177

Energy conversion unit with optimized waveform generation

Sajadian, Sally January 2014 (has links)
Indiana University-Purdue University Indianapolis (IUPUI) / The substantial increase demand for electrical energy requires high efficient apparatus dealing with energy conversion. Several technologies have been suggested to implement power supplies with higher efficiency, such as multilevel and interleaved converters. This thesis proposes an energy conversion unit with an optimized number of output voltage levels per number of switches nL=nS. The proposed five-level four-switch per phase converter has nL=nS=5/4 which is by far the best relationship among the converters presented in technical literature. A comprehensive literature review on existing five-level converter topologies is done to compare the proposed topology with conventional multilevel converters. The most important characteristics of the proposed configuration are: (i) reduced number of semiconductor devices, while keeping a high number of levels at the output converter side, (ii) only one DC source without any need to balance capacitor voltages, (iii) high efficiency, (iv) there is no dead-time requirement for the converters operation, (v) leg isolation procedure with lower stress for the DC-link capacitor. Single-phase and three-phase version of the proposed converter is presented in this thesis. Details regarding the operation of the configuration and modulation strategy are presented, as well as the comparison between the proposed converter and the conventional ones. Simulated results are presented to validate the theoretical expectations. In addition a fault tolerant converter based on proposed topology for micro-grid systems is presented. A hybrid pulse-width-modulation for the pre-fault operation and transition from the pre-fault to post-fault operation will be discussed. Selected steady-state and transient results are demonstrated to validate the theoretical modeling.

Page generated in 0.0999 seconds