• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 16
  • 4
  • Tagged with
  • 21
  • 10
  • 9
  • 8
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Développement d'un analyseur de gaz transportable : couplage thermodésorbeur / micro-chromatographe / spectromètre de masse (m-TD / m-CG / SM)

COZIC, Ronan 24 June 2004 (has links) (PDF)
Les composés organiques volatils (COV) jouent un rôle central dans la pollution atmosphérique photochimique. Le suivi de ces produits dans l'air est devenu une nécessité, en raison de leur nocivité. Actuellement, les méthodes classiques d'analyse de l'air présentent certains inconvénients. Les instruments sont trop spécifiques ou bien la technique consiste à piéger les polluants et retourner ensuite l'échantillon au laboratoire pour l'analyse. La thèse a pour thème la mise au point d'une technique analytique in situ, offrant de nouvelles perspectives pour l'analyse de l'air. L'analyseur transportable développé résulte du couplage d'un thermodésorbeur (m-TD), d'un micro-chromatographe (m-CG) et d'un spectromètre de masse (SM). L'instrument permet, en quelques minutes, de conduire l'analyse qualitative et quantitative d'une très large gamme de COV à l'état de traces. Un exemple d'application de l'analyseur sur site concerne la caractérisation dans le temps d'atmosphères de travail.
12

Identification et quantification de métabolites séléniés dans l'urine humaine

Klein, Marlène 17 December 2010 (has links) (PDF)
La barrière entre l'aspect bénéfique du sélénium (Se) et son aspect toxique est étroite. Afin de mieux contrôler les apports de cet élément dans l'alimentation, de nombreux travaux s'intéressent à la compréhension de son métabolisme. Cette thèse présente le développement et l'optimisation de méthodes d'analyse des espèces séléniées dissoutes et volatiles présentes dans l'urine de sujets non supplémentés. Le couplage entre la chromatographie liquide et la spectrométrie de masse atomique précédé d'un prétraitement de l'échantillon par extraction sur phase solide a permis non seulement de confirmer la présence de métabolites séléniés précédemment détectés dans l'urine de sujets supplémentés mais également, de mettre en évidence des composés inconnus. Un de ces composés a été identifié par spectrométrie de masse moléculaire. Les couplages entre la chromatographie gazeuse et les spectrométries de masse atomique et moléculaire, précédés d'une micro-extraction sur phase solide ont été utilisés pour l'analyse des formes volatiles de Se. Ces méthodes ont permis de confirmer la présence de composés séléniés et mixtes Se/S dans les urines de sujets non supplémentés et, de définir des conditions de stockage permettant de préserver la spéciation originelle dans l'échantillon.
13

Développement de nouvelles méthodologies de préconcentration électrocinétique in-situ en électrophorèse capillaire pour l'analyse de traces

Anrès, Philippe 20 September 2012 (has links) (PDF)
L'électrophorèse capillaire, quoiqu'étant une technique analytique très puissante, souffre d'un manque en sensibilité avec les détecteurs spectrophotométriques. Pour palier ce problème il est possible d'utiliser des méthodes de préconcentration électrocinétiques in-situ. Les travaux menés au cours de cette thèse se sont attachés à développer de nouvelles méthodologies de préconcentration électrocinétique. Tout d'abord, il a été montré que le greffage des capillaires de silice avec du polyacrylamide linéaire permet en milieu acide complexe de réduire fortement l'écoulement électroosmotique ce qui favorise la mise en œuvre des techniques de préconcentration. Ensuite, le couplage de deux méthodes de préconcentration, l'amplification de champ électrique avec une injection électrocinétique et du sweeping a été examiné. En étudiant le mécanisme grâce à des plans d'expérience et de la simulation, l'influence des paramètres expérimentaux ainsi que leurs rôles ont été éclaircis et la procédure d'optimisation simplifiée. A la suite de ces résultats, une procédure d'analyse d'herbicides présents dans des eaux de distribution a été développée, permettant leur détection à un niveau proche de celui spécifié par l'Union Européenne sans étape préalable d'extraction. Ensuite, l'utilisation de liquides ioniques à longue chaîne pour améliorer la sensibilité d'une méthode appelée " Micelle to Solvent Stacking " a été étudiée et des améliorations d'un facteur 10 ont été obtenues par rapport aux gains obtenus avec des surfactants classiques (application à des herbicides et des anti-inflammatoires). Enfin, pour améliorer les gains en sensibilité avec de plus une spécificité élevée, une preuve de concept a été développée en utilisant un aptamère pour l'analyse sélective d'Ochratoxine A à l'état de trace dans le vin, ce qui ouvre de nouvelles perspectives pour l'utilisation de cet outil biologique en électrophorèse capillaire.
14

Développement d'une méthode de préconcentration de phosphopeptides sur phase monolithique en puce

Ayed, Ichraf 27 September 2012 (has links) (PDF)
La phosphorylation de protéines est un régulateur clé de voies de signalisation cellulaire. Elle est impliquée dans la plupart des événements cellulaires et contrôle les processus biologiques tels que la prolifération, la différenciation et l'expression des gènes. Une phosphorylation anormale de protéines peut être observée dans diverses maladies comme certains cancers ou maladies neurodégénératives. Ces protéines constituent donc des biomarqueurs potentiels pour le développement d'outils de diagnostic. Cependant les phosphoprotéines peuvent être présentes à faibles concentrations dans les liquides biologiques et des techniques d'enrichissement sélectif des protéines phosphorylées doivent être développées en amont des analyses. L'une des approches les plus courantes est basée sur la chromatographie d'affinité de type IMAC. Le but de ce travail de thèse était de développer un microsystème contenant un monolithe en tant que support solide d'extraction pour réaliser une préconcentration sélective de phosphopeptides par IMAC. La polymérisation par UV et la caractérisation (perméabilité, porosité et surface spécifique) d'un monolithe à base de phosphate de méthacrylate d'éthylène glycol dans des capillaires de silice ont été d'abord réalisées. Puis, nous avons tenté d'optimiser les différentes étapes de l'IMAC (immobilisation du métal, chargement de l'échantillon, lavage et élution). Une immobilisation efficace de zirconium sur le monolithe phosphaté a été démontrée par des mesures de FEO dans un capillaire et a été par la suite confirmée par la rétention d'un phosphopeptide modèle. Nous avons démontré que le monolithe phosphaté était également un support d'échange de cations vis-à-vis de peptides fortement basiques. Les protocoles de chargement et d'élution ont également été étudiés, mais nécessitent encore d'être améliorés. La transposition de l'enrichissement de phosphopeptides par IMAC sur un système miniaturisé a ensuite été envisagée. Nous avons choisi deux matériaux pour la puce : le PDMS, qui est un polymère attractif pour son faible coût, sa facilité de microfabrication, ses excellentes propriétés en termes de biocompatibilité ainsi que ses nombreuses possibilités d'intégration (enrichissement, séparation, détection) et le verre plus communément employé pour développer des microsystèmes analytiques et possédant une bonne transparence aux UV. Toutefois, le PDMS présente deux inconvénients majeurs: son absorption élevée et sa perméabilité importante à l'oxygène qui inhibe la polymérisation radicalaire. A l'exception de quelques tentatives, ce matériau n'a jamais été employé avec succès comme support pour la polymérisation d'un monolithe. Afin de pouvoir surmonter ces problèmes, nous avons étudié plusieurs stratégies de traitement de surface du PDMS tels que le traitement par plasma d'oxygène ou encore le revêtement au borosilicate. Enfin, nous avons démontré que notre module d'IMAC fonctionnait correctement dans un microsystème en verre. Ce module miniaturisé devrait à l'avenir s'intégrer dans un microsystème d'analyse dédié au diagnostic de la maladie d'Alzheimer.
15

Développement d’un système de préconcentration miniaturisé pour la détection de gaz à l’état de trace/Application à la détection de COV et d’explosifs / Developpement of a miniaturized preconcentration system for trace gas detection/Application to COV and explosives detection

James, Frank 06 March 2015 (has links)
Afin de pallier aux problèmes dus aux limites de détection des capteurs et des détecteurs usuels, un système de préconcentration est indispensable. Ce microcomposant permet d’accumuler le ou les vapeur(s) à détecter à l’aide d’un adsorbant et permet de les libérer sous l’effet d’une montée brutale de la température vers un détecteur. Une amplification de la concentration et donc du signal est ainsi obtenue.Cette thèse poursuit le développement d’un préconcentrateur pour la détection de vapeurs toxiques et d’explosifs. Ce préconcentrateur sera constitué d’un microcomposant en silicium rempli d’un adsorbant et muni d’une résistance de chauffage sur sa face inférieure. Des capillaires métalliques permettent d’assurer la circulation du gaz dans le dispositif. Différents types de préconcentrateurs ont été développés avec différents adsorbants afin satisfaire les conditions pour des applications concernant les composés organiques volatils (COV) et les explosifs. L’optimisation des phases d’adsorption et de désorption est cruciale pour le procédé.Le couplage entre un micro-chromatographe et un préconcentrateur a été réalisé et a montré l’apport de ce microcomposant pour la chromatographie. L’analyse d’un mélange de COV a pu être réalisée avec des concentrations initiales de l’ordre de 40 ppb alors que la limite de détection de l’appareillage était de quelques ppm. Un facteur d’enrichissement de 800 a été atteint.L’avantage de l’utilisation du silicium poreux a également été mis en évidence pour l’adsorption de gaz avec des faibles pressions de vapeur saturante. Cette propriété est intéressante pour la préconcentration de vapeur d’explosifs. / In order to overcome problems due to the conventional sensors detection limits, a preconcentration system is required. Accumulation of vapor(s) for detection is possible with an adsorbent and allows releasing them toward a detector, under the effect of a sudden rise of the temperature. Amplification of the concentration and the signal are obtained.This thesis continues the development of a preconcentrator for the detection of toxic gas and explosives. This preconcentrator is made of a silicon microcomponent filled with an adsorbent and a heater at its back. Two metal capillary allow ensuring the gas flow into the device. Various designs of preconcentrators were developed with different adsorbents to satisfy the requirements for volatile organic compounds (VOCs) and explosives applications.The optimization of adsorption and desorption phases is very important for the process.The coupling between a micro-chromatograph and a preconcentrator was conducted and showed the contribution of the microcomponent to the chromatography. Analysis of a VOCs mixture was achieved with initial concentrations in the order of 40 ppb, whereas the detection limit was of a few ppm. An enrichment factor of 800 was achieved.The advantage of using porous silicon was also demonstrated for the gas adsorption with low saturation vapor pressure. This result is interesting for explosive vapor préconcentration.
16

Développement d’une méthode de préconcentration de phosphopeptides sur phase monolithique en puce / Development of a phosphopeptide preconcentration method using monolith in microchip

Ayed, Ichraf 27 September 2012 (has links)
La phosphorylation de protéines est un régulateur clé de voies de signalisation cellulaire. Elle est impliquée dans la plupart des événements cellulaires et contrôle les processus biologiques tels que la prolifération, la différenciation et l'expression des gènes. Une phosphorylation anormale de protéines peut être observée dans diverses maladies comme certains cancers ou maladies neurodégénératives. Ces protéines constituent donc des biomarqueurs potentiels pour le développement d’outils de diagnostic. Cependant les phosphoprotéines peuvent être présentes à faibles concentrations dans les liquides biologiques et des techniques d’enrichissement sélectif des protéines phosphorylées doivent être développées en amont des analyses. L'une des approches les plus courantes est basée sur la chromatographie d'affinité de type IMAC. Le but de ce travail de thèse était de développer un microsystème contenant un monolithe en tant que support solide d'extraction pour réaliser une préconcentration sélective de phosphopeptides par IMAC. La polymérisation par UV et la caractérisation (perméabilité, porosité et surface spécifique) d'un monolithe à base de phosphate de méthacrylate d'éthylène glycol dans des capillaires de silice ont été d'abord réalisées. Puis, nous avons tenté d'optimiser les différentes étapes de l’IMAC (immobilisation du métal, chargement de l’échantillon, lavage et élution). Une immobilisation efficace de zirconium sur le monolithe phosphaté a été démontrée par des mesures de FEO dans un capillaire et a été par la suite confirmée par la rétention d'un phosphopeptide modèle. Nous avons démontré que le monolithe phosphaté était également un support d’échange de cations vis-à-vis de peptides fortement basiques. Les protocoles de chargement et d'élution ont également été étudiés, mais nécessitent encore d’être améliorés. La transposition de l'enrichissement de phosphopeptides par IMAC sur un système miniaturisé a ensuite été envisagée. Nous avons choisi deux matériaux pour la puce : le PDMS, qui est un polymère attractif pour son faible coût, sa facilité de microfabrication, ses excellentes propriétés en termes de biocompatibilité ainsi que ses nombreuses possibilités d'intégration (enrichissement, séparation, détection) et le verre plus communément employé pour développer des microsystèmes analytiques et possédant une bonne transparence aux UV. Toutefois, le PDMS présente deux inconvénients majeurs: son absorption élevée et sa perméabilité importante à l'oxygène qui inhibe la polymérisation radicalaire. A l’exception de quelques tentatives, ce matériau n'a jamais été employé avec succès comme support pour la polymérisation d’un monolithe. Afin de pouvoir surmonter ces problèmes, nous avons étudié plusieurs stratégies de traitement de surface du PDMS tels que le traitement par plasma d’oxygène ou encore le revêtement au borosilicate. Enfin, nous avons démontré que notre module d’IMAC fonctionnait correctement dans un microsystème en verre. Ce module miniaturisé devrait à l’avenir s’intégrer dans un microsystème d’analyse dédié au diagnostic de la maladie d'Alzheimer. / Protein phosphorylation is a key regulator of cellular signaling pathways. It is involved in most cellular events and strictly controls biological processes such as proliferation, differentiation and gene expression. An abnormal phosphorylation can be observed in various diseases such as some cancers or neurodegenerative diseases. Therefore, these proteins are potential biomarkers for the development of diagnostic tools. However, phosphoproteins can be present at low abundance in biological samples and selective enrichment techniques have to be developed prior to the analysis process. One of the most common approaches is based on Immobilized metal affinity chromatography (IMAC). The goal of this work was to develop a microsystem which contains a porous polymer monolith (PPM) as a solid phase extraction for a selective preconcentration of phosphopeptides by IMAC. UV-polymerization and characterization (permeability, porosity and specific area) of a monolith based on ethylene glycol methacrylate phosphate in silica capillaries was first performed. Then, we tried to optimize the different IMAC steps (metal immobilization, sample loading, washing and elution). An efficient immobilization of zirconium on the phosphated PPM was demonstrated by EOF measurements in capillary and confirmed by retention of a model phosphopetide. We demonstrated that the phosphated monolith was also a strong cation exchanger of highly basic peptides. Protocols of loading and elution were also studied but need to be further optimized. Transposition of phosphopeptides enrichment by IMAC on a miniaturized system was then considered. We selected two microchip materials: PDMS is an attractive polymer for its low cost, its ease of microfabrication, its excellent working properties (biocompatibility, UV transparent with low autofluorescence) and many integration possibilities (enrichment, separation and detection) and glass microchip more common and having a good UV transparency. However, PDMS presents two major disadvantages: high absorption property, and oxygen permeability which quench free radical polymerization. Except a few attempts, this material has not been employed successfully as mould for monolith polymerization. To overcome these problems, we investigated several strategies for PDMS surface treatments such as plasma treatment and borosilicate coating. Finally, we demonstrated that our IMAC module performed well on glass microchip. This miniaturized module should be integrated in the future into a microsystem dedicated to the diagnosis of Alzheimer disease.
17

Migration augmentée de l’uranium dans les eaux souterraines par voie colloïdale / Colloid-mediated migration of uranium in groundwater

Maria, Emmanuelle 31 January 2019 (has links)
La connaissance des processus de mobilisation et de migration de l’uranium dans les milieux souterrains est un enjeu majeur pour évaluer les risques environnementaux associés aux activités anciennes ou actuelles d'installations nucléaires en vue d'anticiper et gérer tout impact environnemental. La mobilisation et la migration sont habituellement décrites comme fortement contrôlées par les réactions d'adsorption, la présence de ligands, notamment sous forme colloïdale, étant susceptible de l'augmenter considérablement. La capacité des entités colloïdales à transporter l'uranium sur de longues distances va dépendre de leur origine, de leur composition, de leur structure, de leur stabilité et de leur réactivité, ainsi que de leur capacité à complexer l'uranium de manière forte et irréversible. Cependant, les faibles concentrations colloïdales dans les eaux souterraines s’avèrent parfois être un verrou analytique à la détection et à la caractérisation de la mobilisation et du transport colloïdaux de polluant(s) dans les eaux souterraines. Les protocoles d'extraction des phases colloïdales depuis les sols ou les méthodes destinées à concentrer les colloïdes depuis un échantillon d'eau souterraine ne sont pas toujours optimisés pour à la fois assurer un rendement d'extraction satisfaisant et respecter l'intégrité physiques et chimiques des entités colloïdales.Dans ce contexte, deux axes de recherche ont été définis dans ce travail de thèse afin 1) d’appréhender l’impact de l’utilisation de méthodes de préconcentration sur la phase colloïdale et 2) d’améliorer notre compréhension de la dynamique de mobilisation de l’uranium au sein d’un sol podzolisé et ainsi améliorer les modèles prédictifs du transport colloïdal de l’uranium dans les eaux souterraines.Les méthodes de séparation membranaires permettent de préconcentrer la phase colloïdale des eaux souterraines tout en assurant un recouvrement supérieur à 80%. Elles engendrent néanmoins des modifications des paramètres intrinsèques des entités colloïdales avec en particulier un décalage vers les grandes tailles de la distribution en taille de ces entités ainsi qu’une modification de la distribution des espèces entre phases dissoute et colloïdale. Ces modifications peuvent mener à une mauvaise appréciation non seulement des concentrations colloïdales mais aussi des mécanismes de complexation/sorption impliquant la surface des entités colloïdales et de leur stabilité dans les eaux souterraines. La matière organique constitutive des eaux du sol d’étude a été identifiée comme étant le vecteur principal de la remobilisation de l’uranium dans les eaux de sol, sans toutefois avoir un contrôle total de ce processus. Elle est constituée majoritairement d’acides fulviques et humiques de petite taille qui tendent à s’agglomérer au cours du temps, lors de la lixiviation du sol. La composition moléculaire de la matière organique varie de manière temporelle à la fois à l’échelle de l’horizon superficiel mais aussi le long du profil de sol. Divers processus (réduction, dénitrification…) interviennent durant la migration de la matière organique vers les horizons plus profonds et pourraient modifier ainsi sa nature. A l’échelle de l’horizon superficiel, les mécanismes de mobilisation diffèrent selon l’élément considéré. L’uranium en particulier est mobilisé rapidement mais de manière limitée (<2% du sol considéré), tandis que la matière organique est générée en continu et de manière pseudo-linéaire. / Knowledge of the processes of mobilization and migration of uranium in underground environments is a major challenge to assess the environmental risks associated with ancient or current activities of nuclear facilities in order to anticipate and manage any environmental impact. Mobilization and migration are usually described as strongly controlled by adsorption reactions, the presence of ligands, especially in colloidal form, being able to increase considerably. The ability of colloidal entities to transport uranium over long distances will depend on their origin, composition, structure, stability and reactivity, as well as their ability to complex uranium in a significant and irreversible manner. However, low colloidal concentrations in groundwater sometimes prove to be an analytical lock on the detection and characterization of colloidal mobilization and transport of pollutant(s) in groundwater. Protocols for extracting colloidal phases from soils or methods for concentrating colloids from a groundwater sample are not always optimized to both ensure satisfactory extraction yield and respect physical and chemical integrity colloidal entities.In this context, two lines of research have been defined in this thesis work to 1) to understand the impact of the use of preconcentration methods on the colloidal phase and 2) to improve our understanding of mobilization dynamics of uranium within a podzolized soil and thus improve predictive models of colloidal uranium transport in groundwater.The membrane separation methods make it possible to preconcentrate the colloidal phase of the groundwater while ensuring a recovery greater than 80%. Nevertheless, they cause modifications of the intrinsic parameters of the colloidal entities with, in particular, a shift towards the large sizes of the size distribution of these entities as well as a modification of the species distribution between dissolved and colloidal phases. These modifications may lead to an inaccurate appreciation not only of colloidal concentrations but also of complexation/sorption mechanisms involving the surface of colloidal entities and their stability in groundwater. The constituent organic matter of the study soil waters has been identified as the main vector for the remobilization of uranium in the soil water, without having a complete control of this process. It consists mainly of small fulvic and humic acids that tend to agglomerate over time, during leaching of the soil. The molecular composition of organic matter varies temporally both at the level of the superficial horizon and also along the soil profile. Various processes (reduction, denitrification ...) occur during the migration of organic matter to deeper horizons and could thus change its nature. At the level of the superficial horizon, mobilization mechanisms differ according to the element considered. Uranium in particular is mobilized quickly but in a limited way (<2% of the considered soil), while organic matter is generated continuously and in a pseudo-linear way.
18

Charges à l’interface liquide/solide : caractérisation par courants d’écoulement et application à la préconcentration de molécules biologiques dans un système micro/nanofluidique / Charges at the liquid / solid interface : characterization by streaming current and application to pre-concentration of biological molecules in a micro / nano-fluidics system

Yuan, Xichen 04 November 2016 (has links)
Les charges à l'interface liquide/solide sont un élément originel majeur des phénomènes électrocinétiques observés en micro/nanofluidique. Elles sont donc la colonne vertébrale de mon manuscrit de thèse, qui se décompose en trois parties : Dans la première partie, un rappel des concepts de base sur les interfaces liquides/solides est proposé au lecteur. Il est suivi d'une description des différentes méthodes expérimentales permettant de mesurer le potentiel zeta de couples solide/électrolyte, puis d'une présentation des travaux de la littérature exploitant les charges aux interfaces pour la préconcentration de molécules biologiques dans des systèmes Micro-Nano-Micro (MNM) fluidiques. Ensuite, une deuxième partie est consacrée à la mesure du potentiel zeta par la méthode des courants d'écoulement. Nous y présentons l'amélioration du banc expérimental issu des travaux antérieurs à ma thèse, ainsi que le développement de nouveaux protocoles de préparation des surfaces permettant de rationaliser et de stabiliser les mesures. Une application à un détecteur original de molécules biologiques clos cette deuxième partie. Enfin, la troisième et dernière partie s'intéresse à la préconcentration de molécules biologiques. Une méthode originale de fabrication des dispositifs MNM et les résultats de préconcentration obtenus, très encourageants, sont décrits. Des premiers modèles numériques et phénoménologiques sont proposés, qui mettent en avant l'originalité de notre travail / The charges at liquid/solid interfaces are a key element for both understanding and exploiting the electrokinetic phenomena in micro/nanofluidics. The manuscript of my Ph.D thesis is dedicated to these phenomena, which is divided into three main parts: Above all, a simple overview of charges at the liquid/solid interface is proposed. Then, several common methods for measuring the zeta potential at the liquid/solid interface are described. Next, various effective methods to preconcentrate the biological molecules is presented with the help of the surface charges. Secondly, the streaming current, which is a standard method to measure the zeta potential in our laboratory, is detailed. It contains the upgrade of the experimental setup from the previous version and the development of new protocols, which improve dramatically the stabilization and the reproducibility of the measurements. In addition, an original biological sensor is briefly presented based on these advancements. Lastly, in the final part, we describe a method which is primitively utilised in the fabrication of Micro-Nano-Micro fluidic system. Based on this system, some favorable preconcentration results is obtained. Moreover, numerical simulations are presented to prove the originality of our work
19

Détermination des paramètres d'interaction non-covalente en solution par les méthodes électrophorétiques capillaires. Champ d'application et performances. Rationalisation des protocoles.

Le Saux, Thomas 11 1900 (has links) (PDF)
Les interactions non-covalentes en solution jouent un rôle essentiel dans de nombreux processus chimiques, biologiques, pharmacologiques. Il est donc d'intérêt de pouvoir quantifier ces interactions. Parmi les méthodes de quantification disponibles, l'électrophorèse capillaire semble particulièrement bien adaptée (miniaturisation, absence de phase stationnaire). Au cours de ces travaux, plusieurs systèmes modèles ont été caractérisés au moyen de trois méthodes électrophorétiques (injection directe, électrophorèse d'affinité et analyse frontale): la distribution d'un soluté dans une phase liposomale, l'interaction entre un polysaccharide (héparine) et une protéine (antithrombine III), les seuils d'agrégation de tensioactifs, l'inclusion de petites molécules dans la beta-cyclodextrine. Pour chacun de ces modèles, une attention particulière a été portée aux spécificités des méthodes électrophorétiques utilisées et à l'intérêt de certaines modélisations.
20

Biosorption de l’antimoine par la levure de boulanger Saccharomyces cerevisiae : étude cinétique et thermodynamique en solution et développement de supports pour la spéciation et la préconcentration dans les eaux / Biosorption of antimony by Saccharomyces cerevisiae : kinetics and thermodynamics in solution and development of supports for antimony speciation and preconcentration in water

Marcellino, Sébastien 12 March 2009 (has links)
L’application de la biosorption à l’analyse inorganique est un sujet en plein essor. Dans cette étude, un support à base de cellules de boulanger Saccharomyces cerevisiae a été développé pour la spéciation et la préconcentration des espèces inorganiques de l’antimoine Sb(III) et Sb(V). Nous avons tout d’abord montré qu’il était possible de fixer de manière sélective Sb(III) en présence de Sb(V) sur les cellules dans une large gamme de pH (5-9) et de force ionique (0-0,1M). Un prétraitement thermique de la biomasse (80°C, 30min) permet d’augmenter significativement la cinétique de fixation de Sb(III) sans nuire à la séparation. L’élution de Sb(III) par l’acide thioglycolique à pH 10 est rapide et quantitative, permettant d’obtenir un facteur de préconcentration proche de 9. Nous avons mis en évidence que la rétention de Sb(V) observée à bas pH était due à des complexation avec les groupements sulfhydryle de la paroi cellulaire. La modélisation des isotherme de sorption de Sb(III) (qmax = 450µg.g-1) ont permis de définir 3 types de sites d’affinité et de coordination différentes. Parmi les matrices testées pour l’immobilisation des cellules, le polysulfone s’avère être le plus performant, alliant perméabilité, faible affinité vis-à-vis de l’antimoine et préservation des sites de fixation. Des colonnes remplies de levures immobilisées ont été couplées à un spectromètre ICP-AES et appliquées avec succès à la spéciation de l’antimoine dans l’eau minérale dopée à faible concentration. Les limites de quantification de Sb(III) ont été améliorées d’un facteur 5 par préconcentration / The application of biosorption to inorganic analysis is an expanding research area. In this study, an analytical support based on baker’s yeast Saccharomyces cerevisiae was developed for the speciation and the preconcentration of inorganic antimony species Sb(III) and Sb(V). It was shown that Sb(III) can be retained selectively by the cells in the presence of Sb(V) in a wide range of pH (5-9) and ionic strength (0-0,1M). Heat pretreatment of the biomass (80°C, 30min) significantly increased the kinetics of Sb(III) uptake without degrading the separation. The elution of Sb(III) by thioglycolic acid at pH 10 was rapid and quantitative, allowing to achieve a preconcentration factor close to 9. Interactions between Sb(V) and the cells, as observed at lower pH, were found to be purely electrostatic, while Sb(III) retention was attributed to the complexation of the species with sulfhydryl groups of the cell walls. Three kinds of sites with different affinities and coordinations were identified by modeling Sb(III) sorption isotherms (qmax = 450µg.g-1). Among the different materials tested, polysulfone was found to be the most suitable matrix for yeast immobilization, combining a good permeability to a low affinity for antimony species and preservation of the sorption sites. Columns filled with immobilized cells were coupled with ICP-AES and successfully applied to antimony speciation in mineral waters samples spiked at low concentration level. The limit of quantification was improved by a factor of 5 by preconcentration

Page generated in 0.1328 seconds