• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 534
  • 269
  • 39
  • 39
  • 23
  • 17
  • 17
  • 17
  • 17
  • 16
  • 11
  • 10
  • 7
  • 4
  • 4
  • Tagged with
  • 1029
  • 457
  • 319
  • 246
  • 131
  • 126
  • 125
  • 115
  • 95
  • 89
  • 84
  • 81
  • 75
  • 73
  • 69
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
351

"Avaliação da força de tração da sela modificada para prótese" / Evaluation of traction force in modified saddle for prosthesis.

Costa, Edna Goncalves da 11 August 2005 (has links)
Do planejamento à execução da prótese mucosa-dento-suportada, a literatura apresenta trabalhos que aponta m as dificuldades do desempenho de uma prótese que se relaciona com tecidos de comportamentos distintos, dente e fibromucosa. Estes trabalhos abordam os problemas biomecânicos e os prejuízos que sofrem o osso e os dentes, sob pressão, durante a mastigação, bem como as dificuldades de distribuição das cargas sobre os tecidos bucais no movimento ocluso-gengival. Porém, essa prótese também sofre forças de tração, por diversas situações clínicas, as quais levam a sela a se deslocar da fibromucosa num movimento gêngivo-oclusal. O objeto desta pesquisa foi desenvolver e testar, em laboratório, um método que possibilitasse à prótese mucosa-dento-suportada dispor de maior retenção na região da fibromucosa, reduzindo o movimento gêngivo-oclusal, e conferindo maior estabilidade à prótese e conforto ao paciente. Para realizar o experimento , foi construída uma base acrílica modificada, correspondente à sela da prótese, com uma canaleta na região que contata a fibromucosa. Esta canaleta foi preenchida com reembasador macio para prótese, à base de silicone. Em seguida, a base foi reembasada no modelo resiliente, especialmente construído para simular a fibromucosa. Uma haste metálica foi fixada em suas extremidades, sendo uma à base acrílica, e a outra extremidade fixada ao mandril do equipamento utilizado para o tracionamento (Versa-Test). Estando a base posicionada sobre o modelo, foram realizados os movimentos de pressão e de tração. A avaliação dos testes foi realizada na base acrílica convencional (sem canaleta) e na base acrílica modificada, cujos valores foram registrados em newton. As bases acrílicas sobre os modelos eram imersas em óleo vegetal, devido ao necessário meio viscoso, com tensão superficial, possibilitando os fenômenos de adesão. Os resultados demonstraram que, na presença de silicone, foi necessária força de tração maior e estatisticamente significante para remover a base do modelo, em relação à base sem silicone. / From the planning to the execution of the tissue-dento-supported prosthesis, the literature presents a range of works standing out the difficulties related to the prosthesis performance when facing distinctive tissues, tooth and fibromucous. These works approach the biomechanical problems and the damages suffered by osseous tissues and teeth under pressure, during the mastication, as well as the difficulties of distribution of the loads on oral tissues in the oclusal-gengival movements. However, this prosthesis also suffers traction forces, in several clinical situations, leading the saddle to move of the fibromucous in a gengival-occlusal movement. The aim of this research was to develop and to test, in a laboratory, a method to improve the tissue-dento-supported prosthesis retention in the fibromucous area reducing the gengival-occlusal movement and allowing a larger stability to the prosthesis and comfort to the patient. In order to accomplish the experiment, a modified acrylic base was confectioned, corresponding to the saddle of the prosthesis and constituted by a small channel in the fibromucous contact area. This channel was filled out with soft reliner for prosthesis, silicon composed. Afterwards, the base was rebased in the resilient model, especially confectioned to simulate the fibromucous. A metallic stem was fixed in two extremities, being one to the acrylic base, and other extremity fixed to the equipment arbor used for the traction (Versa-Test). With the base positioned on the model, the pressure movements and traction were accomplished. The evaluation of the tests was accomplished in the conventional acrylic base (without channel) and in the modified acrylic base, whose values were registered in Newton. The acrylic bases on the models were immersed in the vegetable oil, due to the necessary viscous condition, with superficial tension, making possible the adhesion phenomena. The results demonstrated that in the presence of silicon was necessary a larger and statistically significant traction force to remove the base of the model in relation to the base without silicon.
352

Correlação da tensão no intermediário e as medidas de comprimento, altura e angulação de infraestruturas de próteses sobre implantes / Correlation of abutment tension and measures of length, height and angle of implant-supported prostheses framework

Piras, Fernanda Furtado 28 May 2015 (has links)
A adaptação passiva e estabilidade têm sido descritos como pré-requisitos importantes na escolha dos materiais e técnicas de confecção em prótese implantossuportada. A proposta deste trabalho foi estudar, com auxílio dos strain gauges, a deformação média gerada nos intermediários após a aplicação de carga axial em infraestruturas confeccionadas por três diferentes materiais. Além disso, através da microscopia confocal a laser, avaliar as medidas de comprimento, altura e angulação desses espécimes e mini pilares. Esses dados foram submetidos à análise estatística, a fim de encontrar possível correlação entre a deformação gerada e as medidas internas das infraestruturas com as externas dos intermediários em que foram parafusadas. Para essa investigação foi utilizado um modelo em poliuretano com dois implantes, hexágono externo, posicionados nas áreas dos dentes 43 e 45. A partir deste modelo, 12 infraestruturas de três elementos foram fabricadas e divididas em 3 grupos (n=4) de acordo com a técnica utilizada: (C) fundição convencional em Ni-Cr; (U) usinada em zircônia por CAD/CAM e (S) sinterizada a laser em Co-Cr pelo CAD/CAM. Durante a aplicação de carga axial, as tensões geradas foram registradas por extensômetros unidos aos intermediários, e avaliadas quantitativamente e qualitativamente. De maneira geral, houve um predomínio de áreas de compressão, sendo que as poucas áreas de tração apresentaram baixos valores. O grupo sinterizado a laser foi o único que apresentou forças compressivas para todos os sensores. Os grupos usinado e convencional apresentaram comportamento semelhante, diferindo apenas em uma região. Posteriormente, as infraestruturas e os intermediários foram submetidos à microscopia confocal para avaliação de ângulo, comprimento e altura de suas paredes internas (infraestruturas) e externas (intermediários), nas regiões correspondentes à localização dos strain gauges. Para a angulação, todos os grupos mostraram valores semelhantes entre si e maiores que os dos mini pilares. Quanto ao comprimento e altura, todos valores foram diferentes entre si. Em relação aos mini pilares, os valores foram maiores na altura e menores no comprimento. Estes resultados foram analisados pelo método estatístico de Pearson o que levou à conclusão que, para algumas regiões dos medidores de tensão, há correlação entre deformação e comprimento, e também, deformação e ângulo. Quanto maior o ângulo, e quanto menor for o comprimento, maior a deformação mostrada. / The passive adaptation and stability have been described as important prerequisites in the choice of materials and manufacturing techniques in implant-supported prosthesis. The aim of this work was to study, with the aid of strain gauges, the average deformation generated in the abutment, after application of axial load on frameworks made up of three different materials. Besides, through confocal laser microscopy, assess the length, height, and angle of these specimens, and abutment. These data were statistically analyzed in order to find possible correlation between the deformation generated, and the internal measures of the framework and the external measure of the abutments they were screwed on. For this research, a model made of polyurethane with two external hexagon implants, positioned in the areas of teeth 43 and 45 was used. From this model, 12 three-element frameworks were fabricated and divided into 3 groups (n = 4), according to the technique used: (C) conventional Ni-Cr casting; (U) machined zirconia CAD / CAM and (S) laser sintered Co-Cr by CAD / CAM. During application of axial load, the tensions generated were recorded by strain gauges attached to the abutments, and evaluated quantitatively and qualitatively. In general, there was a predominance of compression areas, and the few areas of traction showed low values. The laser sintered group was the only one with compressive forces for all sensors. The milled and conventional groups behaved similarly, differing only in a region. Subsequently, the framework and the abutment were analyzed by confocal microscopy for evaluation of angle, length and height of the inner (framework) and outer (abutment) walls in regions corresponding to the location of strain gauges. For the variable angle, all groups showed similar values among themselves and greater than the abutments. As for the variables length and height, all values were different. Regarding the abutments, the values were higher in height and smaller in length. These results were analyzed by Pearson statistical method, leading to the conclusion that, for some regions, there was correlation between deformation and length, and also deformation and angle. The higher the angle and the smaller the length, the greater the deformation shown.
353

Níveis de óxido nítrico salivar e indicadores clínicos e bioquímicos de aterosclerose entre usuários de próteses dentárias removíveis / Levels salivary nitric oxide and clinical and biochemical indicators of atherosclerosis between users of removable dental prostheses

Freitas, Dayana 21 September 2016 (has links)
A literatura aborda vastamente a relação entre as inflamações e infecções bucais e a ocorrência de doenças cardiovasculares, entre elas a aterosclerose. Sabemos que o uso de próteses dentárias totais removíveis pode causar inflamação bucal, porém a relação entre inflamações/infecções relacionadas ao uso de próteses e a ocorrência de doenças cardiovasculares ainda não foi suficientemente descrita. O objetivo do presente estudo foi investigar a correlação entre indicadores clínicos e bioquímicos de aterosclerose e os índices de nitrato salivar de usuários de próteses dentárias totais removíveis. Trata-se de um estudo de abordagem quantitativa, correlacional, descritivo, de corte transversal, realizado em uma Unidade de Saúde Preventiva em um município do interior paulista, no período de julho de 2014 a março de 2015. A amostra foi constituída por 44 indivíduos edêntulos totais e usuários de próteses dentárias totais removíveis. Foram avaliadas as variáveis sociodemográficas (sexo, idade, cor da pele, situação familiar conjugal, escolaridade, profissão/ocupação); as características clínicas (medida indireta da Pressão Arterial e Índice Tornozelo Braquial); as variáveis bioquímicas (Colesterol Total e glicemia capilar) e os níveis de óxido nítrico (NO) salivar, obtidos pela dosagem de nitrato realizada por técnica de quimioluminescência. As análises descritivas, com cálculo de frequências absolutas e porcentagens e descrição das médias, desvio padrão e medianas, foram realizadas por meio do pacote estatístico Statistical Package for Social Science - SPSS, versão 16.0. Para análise de correlação linear entre as variáveis foi utilizado o coeficiente de correlação de Spearman. Os resultados foram expressos como valores máximos e mínimos, medianas, médias ± erros padrões das médias (EPM), e as diferenças consideradas estatisticamente significativas para p<0,05. O projeto foi aprovado pelo Comitê de Ética em Pesquisa da Escola de Enfermagem de Ribeirão Preto-USP. A análise do perfil sociodemográfico indicou que a amostra foi composta essencialmente por mulheres, com idade média de 62,9±7,9 anos, cor da pele branca, que conviviam com companheiros e filhos, apresentaram baixos índices de escolaridade e exerciam atividades no próprio lar. A maioria dos participantes (54,4%) informou ter diagnóstico prévio de Hipertensão Arterial Sistêmica e 38,7% apresentaram níveis alterados de pressão arterial no momento da medida. Mais da metade da amostra foi classificada com tolerância diminuída à glicose (56,8%); 22,7% apresentaram níveis elevados de CT e 22,7% apresentaram índices de ITB>1,3, valor indicativo de calcificação arterial. Os participantes apresentaram elevados índices de nitrato salivar, com média de 462,2µM/ml. Não observamos correlação entre as variáveis descritas e os níveis de nitrato salivar. Nossos resultados indicam que a população estudada apresenta fatores de risco para doenças cardiovasculares e aterosclerose. A ausência de correlação entre as variáveis clínicas e bioquímicas e os níveis de NO salivar indicam que, no presente estudo, o NO não se mostrou um bom marcador de alterações sistêmicas. Podemos considerar que os elevados índices de NO salivar indicam possibilidade de inflamações/infecções focais entre usuários de próteses dentárias, contudo são necessários estudos adicionais para averiguar se estas alterações bucais podem levar ao aumento do risco cardiovascular / The literature widely covers the relations between the inflammations and mouth infections and the occurrence of cardiovascular disease, including atherosclerosis. It is known that the use of dental prosthesis, removable or not can cause mouth inflammations, but the linking between the infection related to the use of prostheses and cardiovascular diseases has not been described enough. The purpose of this study was to investigate the correlation of clinical and biochemical indicators of atherosclerosis and salivary nitrates rates of complete denture wearers. It is a quantitative, descriptive and correlational study of a cross section carried out in a Preventive Health Office in a small city in the state of Sao Paulo, from July 2014 to March 2015. In the sample there were 44 edentulous users of removable dental prosthesis. The evaluation included socio-demographic variations (sex, age, skin color, marital status, education degree, profession); clinical characteristics (indirect measure of blood pressure and ankle brachial index) ; biochemical variations (total cholesterol and capillary glycemia) and the levels of salivary nitric oxide (ON), obtained by the nitrate dosing carried out through chemiluminescence technique. The descriptive analysis with calculation of absolute frequencies, percentage and description of standard deviation averages were accomplished through Statistical Package for Social Science_ SPSS, version 16.0. The coefficient of Spearman correlation has been used to analyze the linear correlation among the variations. The results were expressed as maximum and minimum values and difference significant to p 0,05. The Project was approved by the Comite de Etica em Pesquisa da Escola de Enfermagem de Ribeirao Preto - USP. The sócio-demographic analysis has indicated that the sample was compound mostly by women aged from 62,9 about 7,9, White skin,, living with husband and children, who had low education degree and were housewives. Most of the sample (54,4%) iwere previously diagnosed with Systemic Arterial Hypertension and 38,7% showed altered levels of blood pressure at the moment of de measurement. More than 50% of the sample was classified with glucose tolerance diminished (56,8%); 22,7% presented enhanced levels of CT and 22,7% presented index of ITB 1,3, indicative of arterial calcification. The subjects presented high levels of salivary nitrate, average 462,2uM/ml. Correlation between the described variations and the levels of salivary nitrate has not been observed. Our results indicate that the subjects show risk factors to develop atherosclerosis and cardiovascular diseases. The absence of correlation among the clinical and biochemical variations, and the levels of salivary ON indicate that, in this study, the ON has not been a good indicator of systemic alterations. It can be considered that enhanced levels of salivary ON indicate a possibility of focal inflammations among wearers of dental prostheses, although further studies are necessary to check if these oral alterations can increase the cardiovascular risk
354

"Análise comparativa entre sistemas de retenção para próteses auriculares implanto-retidas" / Comparative analyses between retentive systems for implant-retained ear prosthesis

Sousa, Andréa Alves de 03 May 2006 (has links)
As próteses auriculares retidas por meio de implantes osseointegráveis proporcionam maior segurança e conforto, melhorando a qualidade de vida dos pacientes. Este trabalho avalia comparativamente a força de resistência à tração dos sistemas de retenção barra/2 clipes, barra/3 clipes, 2 magnetos, e 3 magnetos, empregados para retenção de prótese auricular. Os sistemas de retenção foram submetidos à ciclagem mecânica, com intervalos de 540 ciclos de inserção e remoção para a simulação de períodos de uso clínico, até um total de 3240 ciclos, sendo, a cada intervalo, submetidos ao ensaio mecânico para força de resistência à tração. Os resultados indicam que os sistemas barra/clipes proporcionam maiores retenções do que os sistemas com magnetos e ao mesmo tempo em que a ciclagem mecânica não interfere na relação entre o número de elementos retentores e a retenção proporcionada dentro dos sistemas barra/clip e dos sistemas magnetos. O sistema barra/2 clipes sofre uma perda significantemente maior da capacidade de retenção frente à ciclagem mecânica, sugerindo uma menor longevidade clínica. A relação da capacidade de retenção entre os sistemas não se altera com a ciclagem mecânica uma vez que, a retenção proporcionada pelo sistema barra/3 clipes mantém-se superior, indicando uma maior durabilidade clínica. As retenções proporcionadas pelos sistemas barra/2 clipes e 3 magnetos, bem como aquelas proporcionadas pelos sistemas 2 e 3 magnetos não diferem ao final da ciclagem mecânica, indicando uma durabilidade clínica semelhante. / Placement of osseointegrated implants for retention of ear prosthesis provides greater security and comfort, improving the quality of life of the patients. This work evaluates and compares the retentive mechanical behavior of bar/2 clips, bar/3 clips, 2 magnets, and 3 magnets retention systems, used for implant-retained ear prosthesis. The systems were submitted to mechanical cycling , with intervals of 540 cycles of insertion and removal, for the simulation of clinical periods of function, up to 3240 cycles, being submitted to the mechanical forces essay at each interval. Data were subjected to Tukey-Kramer procedure and the comparative analyses indicate that the bar/clips systems provide different and better retentive forces than the magnet systems and mechanical cycling does not alter the numerical relative performance of the retainer components within the bar/clip or magnet retention system. The bar/2 clips system shows the biggest and statistically significant loss of the retentive forces during mechanical cycling (p<0,05), suggesting a shorter clinical life. The retention provided by the bar/3 clips system remains superior after mechanical cycling, indicating a longer clinical life. The relation between the retention forces presented within the bar/clip systems and magnets systems does change under mechanical cycling. Also, the relation between the bar/2 clips system and 3 magnets system, as well as between 2 and 3 magnets systems do not differ at the end of mechanical cycling , indicating a similar behavior toward clinical life.
355

Correlação estrutura-propriedades de silicones para prótese facial - Efeitos da pigmentação e do envelhecimento / Correlation structure-properties of silicones for facial prosthesis - Effects of pigmentation and aging

Pinheiro, Juliana Barchelli 13 April 2012 (has links)
Este estudo avaliou a dureza Shore A, alteração de cor, recuperação elástica e resistência ao rasgamento de um silicone experimental (Ortho Pauher - O), quando comparado a um silicone usado em reabilitações faciais (MDX 4-4210 - MDX), quando submetidos à pigmentação e envelhecimento e ainda, analisou a micro estrutura desses materiais. Para análise da alteração de cor e dureza foram obtidos 160 espécimes circulares (80/material); para os ensaios de recuperação elástica foram obtidos 200 espécimes cilíndricos (100/material) e para o ensaio de resistência ao rasgamento, foram confeccionados 200 espécimes em forma de calça (100/material). Metade dos espécimes recebeu pigmentação intrínseca e a outra metade, pigmentação intrínseca e extrínseca, por meio da adição de pó de maquiagem. Em seguida, foram distribuídos aleatoriamente em três grupos de envelhecimento: 1 termociclagem (T), 2 - luz ultravioleta (UV) e 3 - luz natural (LN). O envelhecimento simulou um período de uso de um ano. Como controle (C), os espécimes foram mantidos em um recipiente fechado e na ausência total de luz por um ano. Para as análises micro estruturais, três espécimes de cada grupo foram submetidos à Microscopia Eletrônica de Varredura (MEV), Espectroscopia no Infravermelho (EI), Calorimetria Exploratória Diferencial (DSC) e Termogravimetria (TG). Os dados foram submetidos à Análise de variância e Teste Complementar de Tukey (p<0,05). Os resultados das análises micro estruturais foram apresentados em tabelas e gráficos. Para alteração de cor, não houve diferença entre os materiais e pigmentação. Os envelhecimentos por UV, LN e T promoveram a maior alteração. O MDX apresentou alterações em função da PIE, T e UV e o Ortho Pauher, em função da PI/UV e PIE/T e UV. Para a dureza, o silicone Ortho e a PI apresentaram as maiores alterações, bem como a LN e a UV. Ambos os materiais variaram em função das pigmentações e envelhecimento. Para resistência ao rasgamento houve diferença para todos os fatores e para a interação. O silicone O e a PI promoveram as menores médias. O MDX sofreu alteração em função da pigmentação e do envelhecimento. Na recuperação elástica, o material M apresentou a maior média, bem como o grupo PIE. Para o envelhecimento, a UV resultou em menor recuperação e os maiores valores foram encontrados no C e LN. Os dois materiais variaram em função da pigmentação e envelhecimento. As análises micro estruturais demonstraram que a polimerização dos materiais foi completa e que os pigmentos adicionados, nas proporções utilizadas, não influenciaram na estabilidade dos materiais. O resultado do estudo sugere que as alterações encontradas nas propriedades físico-mecânicas, em função da exposição às diferentes pigmentações e envelhecimento não representam diferenças estruturais importantes e que o silicone experimental merece estudos com vistas em sua aplicabilidade clínica e que o silicone experimental precisa ser estudado com vistas em sua aplicabilidade clínica. / This study evaluated the color change, Shore A hardness, tear resistance and elastic recovery of an experimental silicone (Ortho Pauher - O), compared to a silicone used in facial rehabilitation (MDX 4-4210 - MDX), when submitted to pigmentation and accelerated aging and also examined the microstructure of these materials. To analyze the color change and hardness, we were obtained 160 circular specimens (80/material); for the elastic recovery, 200 cylindrical specimens were obtained (100/material) and for the tear strength, 200 specimens were fabricated in the form of pants (100/material). Half of the samples received intrinsic pigmentation and the other half received intrinsic and extrinsic pigmentation, also by applying makeup powder. Subsequently, the specimens were randomly distributed into three groups of aging: 1 - thermocycling (T), 2 - ultraviolet light (UV) and 3 - natural light (NL). All of the aging steps simulated a period of 1-year. As a control (C), the specimens were kept in a closed container in total absence of light for 1-year. For the micro structural analysis, three specimens of each group were subjected to Scanning Electron Microscopy (SEM), Infrared Spectroscopy (EI), Differential Scanning Calorimetry (DSC) and Thermogravimetry (TG). For statistical analysis tests were used ANOVA and Tukeys test (p<0.05). For the micro structural analysis, the results were presented in tables and graphs. For color change, there was no difference between the materials and pigmentation. The UV, LN and T aging, promoted the greatest change. MDX was altered in function of the IEP, T and UV and Ortho Pauher, according to the PI/UV and IEP/T and UV. For hardness, Ortho Pauher silicone and IP showed the greatest changes, as well as the LN and UV. Both materials varied depending on the pigmentation and aging. For tear strength, difference was found for all factors and interaction. The Silicone Ortho Pauher and IP promoted the lowest averages. The MDX was altered depending of the pigmentation and aging. In the elastic recovery, the material M and the PIE group showed the highest average. For aging, UV resulted in lower recovery and higher values were found in the C and LN. The two materials were changed according to pigmentation and aging. The micro structural analyzes showed that the polymerization was completed and the material and the pigments added, in the proportions used, do not influence the stability of the materials. The study results suggest that the changes found in physical-mechanical properties, depending on exposure to different pigmentation and aging, do not represent important structural alterations and the experimental silicone needs to be studied with a view to its clinical applicability.
356

Análise biomecânica in vitro de pilares estéticos de zircônia personalizados e não personalizados / In vitro biomechanical analysis of customized and not customized aesthetic zircônia abutment

Moris, Izabela Cristina Mauricio 19 May 2015 (has links)
Atualmente os implantes passaram a ser uma opção viável de tratamento para se obter uma adequada reabilitação oral, sendo que a estética tem se tornado um fator de grande importância na Odontologia. Os pilares em zircônia tem-se apresentado como uma boa alternativa que vem preencher o fator estético, não contemplado pelos pilares metálicos. O objetivo deste estudo foi avaliar a resistência à fratura dos pilares de zircônia personalizados e não personalizados e o efeito da ciclagem termomecânica sobre a adaptação marginal, perda de torque e resistência à cimentação destes pilares. Para avaliar a resistência à fratura, 18 implantes cone morse foram utilizados e estes foram divididos em três grupos: GZr: 6 conjuntos implantes/pilares em zircônia; GZrp: 6 conjuntos implante/pilares em zircônia personalizados e GTi: 6 conjuntos implante/pilares em titânio (controle). Os conjuntos implante/pilar foram submetidos à carga compressiva oblíqua em máquina universal de ensaios, com célula de carga de 500kgf e velocidade de 0,5mm/min, em angulação de 30°. Para avaliar os efeitos da ciclagem termomecânica foram utilizados 24 implantes cone morse e estes foram divididos em três grupos: GZr: 8 conjuntos implantes/pilares em zircônia; GZrp: 8 conjuntos implante/pilares em zircônia personalizados e GTi: 8 conjuntos implante/pilares em titânio (controle). Os pilares foram instalados com o torque recomendado pelo fabricante (15Ncm). Coroas cerâmicas foram confeccionadas para todos os grupos. A adaptação marginal das coroas foi avaliada antes e após a ciclagem termomecânica e a resistência de cimentação das coroas foi avaliada após a ciclagem termomecânica através do ensaio de tração. Os conjuntos foram submetidos a 1.000.000 ciclos mecânicos e 8.400 ciclos térmicos. A análise estatística utilizada para o teste de resistência à fratura foi Anova com teste complementar de Tukey. O Grupo GZrp apresentou resistência a fratura significantemente maior que GZr (p=0,009) e o GZr foi semelhante ao GTi. Para a análise da perda de torque e adaptação marginal foi utilizado o modelo linear de efeitos mistos. Para a adaptação marginala análise estatatística revelou haver diferença entre os grupos GZrp e GTi (após ciclagem p=,010) porém não houve diferença dentro do mesmo grupo nos diferentes tempos (antes e após ciclagem termomecânica). Para a perda de torque a análise estatística revelou não haver diferenças significantes, antes e após a ciclagem termomecânica, dentro dos grupos, porém entre os grupos houve diferenças estatísticas entre GZr e Gti antes da ciclagem . Para a análise da resistência de cimentação das coroas foi utilizado ANOVA e este revelou não haver diferenças significantes entre os grupos. Sendo assim, conclui-se que a personalização dos pilares de zircônia não afeta suas propriedades mecânicas, e que o comportamento dos pilares de zircônia é semelhante aos pilares de titânio o que viabiliza o seu uso clínico. / Now implants have been a viable option of treatment for reaching an adequate oral rehabilitation, once the aesthetic have become a factor of great importance in Dentistry. The zirconia abutments have appeared as a good alternative to fill the aesthetic factor that is not present in the metallic abutments. The aim of the present study was to evaluate the fracture strength of customized and not customized zirconia abutments and the effect of thermomechanical cycling in the marginal fit, torque loss and cementation resistance of these abutments. For fracture strength evaluation, 18 morse taper implants were used and divided into three groups: GZr: 6 sets of implants/zirconia abutments; GZrp: 6 sets of implants/customized zirconia abutments and GTi: 6 sets of implants/titanium abutments (control). The sets were submitted to compressive oblique loading in universal testing machine, with a load cell of 500kgf and 0.5mm/min speed, in a 30 degree angulation. For evaluation of the thermomechanical cycling effect, 24 morse taper implants were used and divided into three groups: GZr: 8 sets implants/zirconia abutments; GZrp: 8 sets implants/customized zirconia abutments and GTi: 8 sets implants/titanium abutments (control). The abutments were installed with the torque recommended by the manufacturer (15Ncm). Ceramic crowns were made for all groups. The marginal fit of crowns was evaluated before and after thermomechanical cycling and the cementation resistance of crowns was evaluated after thermomechanical cycling by tensile strength test. The sets were submitted to 1,000,000 mechanical cycles and 8,400 thermal cycles. The fracture strength data were statistically analyzed by ANOVA and Tukey\'s test. The GZrp group presented fracture strength statistically greater than GZr (p=.009) and GZr was similar to GTi. Marginal fit and torque loss data were analyzed by mixed linear model. In the marginal fit, significant difference was noted between GZrp and GTi (after: p=.010), but no difference was noted in the group at different times (before and after thermomechanical cycling).For torque loss, no significant difference was noted before and after thermomechanical cycling in the groups, but significant difference was noted between Gzrp and GTi after thermomechanical cycling. Cementation resistance of crowns was analyzed by ANOVA and no significant difference was noted among the groups. Thus, it was concluded that customization of zirconia abutments does not affect their mechanical properties, and the behavior of zirconia abutments is similar to titanium ones, enabling its clinical use.
357

Avaliação da relação entre o desajuste vertical em interfaces pilar/cilindro protético fundido e sobrefundido e a perda de torque de parafusos protéticos de titânio / Evaluation of the relationship between vertical misfit in abutment / casting and pre-machined prosthetic cylinder joint and loosening of prosthetic titanium screws

Falcão Filho, Hilmo Barreto Leite 15 December 2005 (has links)
Este estudo foi desenvolvido com o objetivo de avaliar os níveis de desajustes em interfaces pilar / cilindros protéticos obtidos a partir de cilindros calcináveis e pré-usinados fundidos em duas diferentes ligas metálicas, e a perda de torque em parafusos protéticos de titânio utilizados para fixar estas interfaces, analisando a relação entre estas variáveis. Os parafusos protéticos foram submetidos a análises de microscopia eletrônica de varredura antes e após o aperto. Os valores de torque foram aferidos por um torquímetro digital, os valores de desajustes registrados por um microscópio óptico e foram registradas imagens dos corpos-de-prova por uma câmera digital acoplada a outro microscópio óptico. Todos os valores de desajustes e perda de torque foram submetidos a testes de freqüência e analisados pelos testes T e Mann-Whitney para comparação entre os grupos, e pelo teste Spearman para a verificação da correlação entre as variáveis. Os resultados evidenciaram diferenças estatisticamente significantes (p &#8804; 0,05) para os diferentes tipos de cilindros utilizados quanto ao desajuste (p = 0,000), e não foram evidenciadas diferenças estatísticas significantes (p &#8804; 0,05) entre os cilindros quanto à perda de torque (p = 0,052) nem entre as diferentes ligas quanto ao desajuste (p = 0,615) e perda de torque (p = 0,811). A análise estatística confirmou a correlação (p &#8804; 0,05) entre as variáveis desajuste e perda do torque (p = 0,017). Foram verificadas alterações nas superfícies das roscas dos parafusos após o torque e defeitos de fundição em alguns cilindros protéticos, especialmente nos cilindros fundidos a partir de cilindros calcináveis. De acordo com os resultados, a metodologia empregada e as limitações deste estudo, concluiu-se que os cilindros pré-usinados proporcionam níveis de desajustes mais favoráveis do que os cilindros calcináveis, existe correlação entre os desajustes nas interfaces pilar / cilindro protético e perda de torque nos parafusos de titânio, e defeitos de fundição podem influenciar nos desajustes. / This study was developed with the objective to evaluate the levels of misfit in abutment / coping joint obtained from casting and pre-machined copings in two different alloys and the torque loosening in prosthetic titanium screws used to connect this joint, analyzing the relation between the two variable. The prosthetic screws were submitted to analyses on scanning electron microscopy before and after the torque. The values of torque were checked by one digital torque meter, the values of misfits were registered by an optic microscope and images of the samples were registered by an digital camera connected to another optic microscope. All the values of misfits and torque loosening was submitted to frequency tests and analyzed by the T and Mann-Whitney tests for the comparison between the groups, and by the Spearman test for the verification of the correlation between the two variable. The results had evidenced significant statistical differences (p &#8804; 0,05) for the different types of copings used about misfit (p = 0,000), and had not been evidenced significant statistical differences (p &#8804; 0,05) between the copings about the torque loosening (p = 0,052), neither for the different alloys about misfit (p = 0,615) and torque loosening (p = 0,811). The statistical Spearman test analysis confirmed the correlation between the misfit and torque loosening (p = 0,017). It was verified alterations in the surfaces of the threads of the screws after the torque and casting defects in some prosthetic cylinders, especially in the casting cylinders. In accordance with the results, the employed methodology and the limitations of this study, it has been concluded that the pre-machined copings provide more favorable levels of misfits than the casting copings, there is correlation between misfits in the abutment / coping joints and torque loosening in the titanium screws, and casting defects should influence in the misfits.
358

Evolução dos sistemas de retenção, fixação e ancoragem extraoral na reabilitação bucomaxilofacial: revisão sistemática / Evolution of retention, fixation and anchorage extraoral in maxillofacial rehabilitation systems: a systematic review

Cobein, Marcus Vinicius 02 July 2014 (has links)
Introdução: A utilização de próteses bucomaxilofaciais é de extrema importância para a reintegração no convívio social dos pacientes acometidos de deformidades congênitas ou adquiridas. Tendo em vista os avanços dos sistemas de retenção, fixação e ancoragem extraoral na reabilitação bucomaxilofacial realizou-se revisão sistemática. Objetivos: verificar a evolução das retenções das próteses bucomaxilofaciais comparando os sistemas osseointegrados, aos sistemas não osseointegrados, analisando algumas variáveis como: taxa de sobrevivência dos implantes ao longo do tempo, idade média dos pacientes, etiologia do defeito facial e sitio dos sistemas de retenção relacionado ao tipo de prótese, em formato de revisão sistemática. Métodos: Realizou-se busca bibliográfica nas bases de dados PubMed e SCOPUS, após elaboração de estratégias de busca, obteve-se 2630 artigos onde foram analisados títulos, resumos e eliminadas duplicidades. Resultados: Obteve-se 25 artigos pré-selecionados que passaram pelos critérios de inclusão e exclusão sendo eleitos 13 artigos para a revisão sistemática. Conclusão: As próteses retidas por implantes superam os sistemas convencionais. A perda dos implantes foi muito pequena nos estudos analisados, apesar do tempo de acompanhamento ser relativamente curto e dos protocolos distintos de tratamento. A idade adulta entre a quarta e quinta década de vida foi a de maior prevalência. A etiologia mais incidente são as neoplasias. Os sistemas osseointegrados fixados por implantes por retenção barra clipe se localizam mais na região auricular e retenção magnética nas regiões nasal e orbital. Os sistemas não osseointegrados, a retenção anatômica é mais utilizada na região ocular, retenção mecânica na região orbital e o uso da retenção por adesivos nas regiões nasal e orbital. / Introduction: The use of maxillofacial prostheses is the most importance for reintegration into social life of patients suffering from congenital or acquired deformities. Given the advances in retention, fixation and extraoral anchorage systems in maxillofacial rehabilitation got systematic review. Objectives: To observe the evolution of the retentions of maxillofacial prostheses comparing osseointegrated systems, non osseointegrated systems, analyzing some variables such as survival rate of implants over time, mean patient age, etiology of facial defect and place restraint systems related kind of prosthesis, in a systematic review format. Methods: We performed a literature search in PubMed and SCOPUS database, after preparation of search strategies, we obtained 2630 articles where were checking titles, abstracts and eliminated duplicates were analyzed. Results: We obtained 25 pre-selected articles that passed the criteria for inclusion and exclusion being elected 13 articles for systematic review. Conclusion: The dentures retained by implants outperform conventional systems. The loss of the implants was very small in the analyzed studies, although the follow-up time is relatively short and the different treatment protocols. Between the fourth and fifth ages of life was the most prevalent. The most frequent etiology are neoplasms. Osseointegrated systems for fixed for implants retention bar clip are located more auricular and magnetic retention in the regions nasal and orbital. Non osseointegrated systems, anatomical retention is most commonly used in the ocular region, mechanical retention in orbital region and the use of adhesives for retention in the regions nasal and orbital.
359

Incidência de fraturas em próteses fixas: estudo retrospectivo. Análise da sobrevivência de próteses metalocerâmicas após um período mínimo de quatro anos em função / Fractures Incidence on fixed prostheses: a retrospective study

Azevedo, Fabiola Pontes 09 August 2017 (has links)
As próteses metalocerâmicas ainda são apontadas como o tratamento de escolha em reabilitação oral por apresentarem altas taxas de sobrevivência, mesmo que o fator estético possa ser comprometido devido às propriedades óticas relacionadas à infraestrutura metálica. Além disso, há pouca informação na literatura científica sobre os fatores que levam às fraturas das próteses fixas metalocerâmicas. Com isso, o presente estudo teve como objetivo avaliar se a quantidade de elementos que compõe uma prótese, se a quantidade de elementos por retentor, se o tipo de prótese, se o tipo de pilar, se a localização da prótese, se o bruxismo e se a utilização de placa miorrelaxante influenciam na incidência de fraturas em próteses fixas metalocerâmicas. Para este estudo, foram selecionados 16 pacientes, totalizando 74 próteses metalocerâmicas, instaladas entre 2000 e 2010, que tiveram um acompanhamento mínimo de 4 anos. Foram coletados dados, como: gênero, idade, data de instalação das próteses e sistema cerâmico utilizado. Foi realizada a avaliação clínica considerando integridade da prótese, características do elemento antagonista e coleta da história odontológica em caso de fratura, além de um questionário para identificar provável ou possível bruxismo. Foram determinadas as taxas de sucesso, insucesso e sobrevivência da mesma. Os resultados mostraram que a taxa de sucesso das próteses metalocerâmicas instaladas foi de 87,8% e a taxa de sobrevivência foi de 89,1%. Além disso, a taxa de sucesso não foi influenciada pela idade (p=0,903), tempo de instalação (p=0,830), número de próteses na boca (p=0,872), número de elementos (p=0,937) e número de pilares (p=0,064). Para as variáveis qualitativas também não houve diferença estatística significante (p>0,05) entre as proporções das taxas de sucesso e insucesso. Contudo, os resultados mostraram que pacientes que não usavam placa miorrelaxante tiveram taxa maior de sucesso que os pacientes usuários de placa (p=0,004). Assim, pode-se concluir que as próteses metalocerâmicas apresentam altas taxas de sucesso e sobrevida garantindo a longevidade desse tipo de reabilitação. / Metal-ceramic prosthesis are still the treatment choice in oral rehabilitation because they present high survival rates, even if the aesthetic can be compromised due to optical properties related to metallic infrastructure. In addition, there is little information on scientific literature about factors that lead to fractures of fixed metalceramic prosthesis. The purpose of this study was to evaluate if prosthesis elements number, number of elements per prosthetic abutment, type of prosthesis, type of prosthetic abutment, the prosthesis location, bruxism and myorelaxant plaque influences on incidence of fractures in fixed metal-ceramic prosthesis. For this study, 16 patients were selected totaling 74 metal-ceramic dentures installed between 2000 and 2010 with a follow-up of at least 4 years. Data were collected, such as: gender, age, prosthesis installation date and the ceramic system used. Besides a questionnaire to identify probable or possible bruxism, a clinical evaluation was performed to evaluate prosthesis integrity, antagonist element characteristics and dental history in case of fracture. Success, failure and survival rates were determined. The results showed that the success rate of metal-ceramic prosthesis was 87.8% and the survival rate was 89.1%. In addition, the success rate was independent of age (p=0.903), installation time (p=0.830), number of prosthesis (p=0.872), elements (p=0.937) and abutments (p=0.064). The qualitative variables also did not show significant statistical results (p> 0.05) between success and failure rates. However, the results showed that patients who did not use myorelaxant plaque had a higher success rate than plaque users (p=0.004). Thus, it can be concluded that the metal-ceramic prosthesis has high success and survival rates, ensuring longevity of this type of rehabilitation.
360

Análise comparativa do grau de rotação de parafusos para sistema UCLA em estruturas fundidas em monobloco, soldadas com solda TIG e solda convencional / Comparative analysis of the degree of rotation of screws for UCLA system in one-piece cast structures welded with TIG and Conventional welding

Mansano, Romão Adalberto de Souza 14 October 2011 (has links)
Com disseminação dos implantes osseointegrados na pratica clinica a ocorrência de complicações mecânicas tornam-se comuns, causando problemas para pacientes e profissionais. O objetivo deste estudo foi comparar o grau de rotação de parafusos de titânio (grau 5), durante testes de torque, re-torque e os valores de destorque (Ncm), sobre infra-estruturas fundidas em monobloco, soldadas com solda TIG e solda Convencional, a partir de abutments tipo UCLA com cinta usinada em Co-Cr. Um dispositivo leitor da quantidade de graus foi especialmente desenvolvido para este estudo, juntamente com um software. Seis implantes Titaniun Fix de 3,75 mm de diâmetro e 13 mm de comprimento e hexágono externo foram montados na base de um dispositivo e diretamente sobre eles foram obtidos os padrões para fundição dos corpos de prova. Para os grupos que foram submetidos a soldagem os corpos foram montados à análogos de implantes Titaniun Fix, e vazados blocos de gesso especial tipo IV (Durone) para serem seccionados e fundidos. Cada corpo de prova foi formado por dois abutments tipo UCLA com cinta em Co-Cr, interligados por uma barra acrílica. Foram obtidos 10 corpos de prova para cada grupo e 60 parafusos de titânio (Grau 5- Titaniun Fix) foram usados para os testes. Obteve-se então a medição do ângulo criado durante o aperto e re-aperto dos parafusos, sendo o re-aperto realizado após 10 minutos do aperto inicial, ambos sob torque de 30Ncm. Após o procedimento de re-aperto, o valor de destoque era imediatamente aferido e anotado em Ncm, possibilitando avaliar a quantidade de torque retido pelo parafuso após o procedimento, sendo esta seqüência realizada 3 vezes para cada corpo de prova. Sendo a análise estatística realizada para essa comparação (ANOVA) Análise de Variância a um critério de classificação, o teste Tukey, para verificar se havia diferença estatística entre os grupos. Os resultados revelaram que durante os procedimentos de torque (aperto), os parafusos empregados em infra-estruturas fundidas em monobloco apresentaram um maior grau de rotação (56,12°), quando comparados aos parafusos empregados em infra-estruturas segmentadas e fundidas separadamente soldadas com solda TIG valor médio de (43,2°) e solda Convencional com valor médio (35,7°), sendo a diferença entre os grupos estatisticamente significante em todos os grupos para o momento torque; p<0,05. Durante o momento re-torque, o ângulo formado na cabeça dos parafusos também foi sempre maior para o grupo monobloco (15,55°) , comparado aos grupos solda TIG (10,15º) e solda Convencional (9,85°) , sendo que diferença estatisticamente significante foi encontrada entre os grupos monobloco em relação aos grupos soldados, e não havendo diferença estatística entre os grupos soldados, p<0,05. Os valores médios de destorque (quantidade de torque retido durante o aperto dos parafusos) foram maiores para o grupo solda TIG (26,77Ncm) em relação aos grupos monobloco (26,55Ncm) e grupo solda Convencional (25,10Ncm) respectivamente, porém sem diferença estatisticamente significante entre os grupos. Tanto para o momento de torque quanto para o momento de re-torque, infra-estruturas do grupo Monobloco permitiram maior rotação dos parafusos dos abutments, quando comparados com os grupos Soldados. Na análise dos valores de destorque, estatisticamente os grupos foram considerados semelhantes. / With the spread of osseointegrated implants in clinical practice the incidence of mechanical complications have become common, causing problems for patients and professionals. The aim of this study was to compare the degree of rotation of titanium screws, during testing of torque, re-torque and destorque values (Ncm) in one-piece casting infrastructures, welded with TIG and Conventional welding, from UCLA strap machined Cr-Co abutments. A reader device for the number of degrees has been specially developed for this study, together with a software. Titaniun Fix implants (n=6) of 3.75mm in diameter and 13mm in length and external hexagon were mounted at the base of a device and they were obtained directly from the casting patterns of the specimens. Groups that were subjected to welding were mounted to the implant analogues, submitted to special plaster type IV (Durone) blocks. Each sample was formed by two UCLA type abutments with strap on Co-Cr, connected by an acrylic bar. It were obtained 10 specimens for each group and 60 titanium screws (Grade 5 - Titaniun Fix) were used for testing. The measurement of the angle created during tightening and re-tightening the screws, and re-grip performed 10 minutes after the initial torque, both under torque 30Ncm were obtained. After re-tightening procedure, the value of destoque was immediately measured and recorded in Ncm, to evaluate the amount of torque by the screw retained after the procedure, being this sequence performed three times for each specimen. The statistical analysis used were, analysis of variance (1 way - ANOVA) and the Tukey test to see whether there were differences between the groups. The results revealed that during the procedures of torque (tightening), the screws used in the one-piece infrastructure castings showed a higher degree of rotation (56,12°) compared to the screws used on targeted infrastructure and rendered separately welded with TIG (43,2°) and Conventional welding with a mean value (35,7°), bei ng the difference between the groups statistically significant in all groups for the torque moment (p<0.05). During the re-torque, the angle formed at the head of the screws was also always greater for the one-piece casting group (15,55°) compared to TI G welding groups (10,15°) and Conventional welding (9,85°), and significant diffe rences were found between the groups (p<0.05). The average values of destorque (retained amount of torque when tightening the screws) were higher for the TIG welding group (26,77Ncm) compared to one-piece casting groups (26,55Ncm) and Conventional welding group (25,10Ncm), respectively, however no statistically significant difference between groups were found. For both the torque and re-torque moments, one-piece infrastructure group allowed more rotation of the abutment screws when compared with the welded groups. In the analysis of destorque values, the groups were statistically similar.

Page generated in 0.049 seconds