• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 32
  • 3
  • 3
  • 3
  • 1
  • 1
  • Tagged with
  • 48
  • 27
  • 18
  • 13
  • 12
  • 12
  • 7
  • 6
  • 5
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

En undersökning av snabbkopplingsadapterns nödvändighet : Ett fenomenologiskt examensarbete / An investigation of the quick change adapter’s necessity : A phenomenological thesis

Wilsborn, Karl, Heggdal, Kennet January 2020 (has links)
Syfte: Syftet med det här examenarbete är att undersöka behovet av snabbkopplingsadaptrar för protesbrukare.   Bakgrund: Snabbkopplingsadapter är en förhållandevis ny produkt som både Otto Bock och Lindhe Xtend erbjuder, men ingen forskning på behovsområdet finns ännu gjord. Fördelen med produkten är enligt leverantörernas hemsidor bl a att man med den enkelt kan byta mellan olika proteskomponenter utan att behöva skruva på några protesinställningar eller byta hylsa.   Metod: För att undersöka behovet av snabbkopplingsadaptrar utfördes semistrukturella intervjuer av fenomenologisk karaktär. En serie med sju frågor sammanställdes som intervjuunderlag, vilka togs fram utifrån de tre behovsfokusområdena: Funktion, delaktighet och livskvalité. I undersökningen ingick n=6 deltagare, varav n=3 transtibialt amputerade och n=3 transfemoralt amputerade. Insamlade data analyserades vidare för framtagning av olika teman och resultat.   Resultat: Utifrån intervjuunderlaget togs följande teman fram: Byte av protesfötter/protesknäleder, På- och avtagning av byxor, Hylspassform, Transport samt Biomekanik. Varje tema utgjorde ett eget potentiellt användningsområde, där de största behoven visade sig ligga inom temana Byte av protesfötter/protesknäleder, Hylspassform samt Transport.   Slutsats: Behovet av snabbkopplingsadaptrar är högst subjektivt, och beror snarare på deltagarens liv än några allmänna faktorer. Däremot upptäcktes ett antal tänkbara användningsområden för den. / Aim: The aim of this thesis was to investigate the necessity of the quick change adapter for lower limb amputees.   Background: Quick Change Adapter is a relatively new product that both Otto Bock and Lindhe Xtend offers, but no research has been done on the area of its necessity yet.  According to the supplier´s websites the benefits of the product is that you with it easily can change prosthetic components without affecting the alignments or change socket.   Method: To investigate the necessity of the Quick Change Adapter, semi structural interviews of phenomenological characteristic were used.  A series of seven questions were compiled as a basis for the interview from the three focus areas: Function, participation and quality of Life. The thesis involved n=6 participants, of who n=3 was trantibial amputated and n=3 transfemoral amputated. Collected data was later analysed to find general themes and results.   Results: From the interviews these themes were exposed: Changing prosthetic feet/prosthetic knee joints, Donn and doff of pants, Socket fit, Transport and Biomechanics. Each theme presented a potential application area where the biggest needs seemed to be in Changing prosthetic feet/prosthetic knee joints, Socket fit and Transport.   Conclusions: The necessity of the Quick Change Adapter turned out to be very subjective, and depended more on the participant´s life then any general factors. Still there were some potential application areas detected for it.
32

A doença reumática no ciclo gravído-puerperal / Rheumatic disease in pregnancy and childbirth

Andrade, Januario de 09 December 1981 (has links)
A fim de avaliar o resultado da gestação em pacientes cardíacas foram considerados dois grupos controle: o grupo \"I\" ou clínico e o grupo \"II\" ou cirúrgico. Foram considerados para este estudo todas as pacientes reumáticas matriculadas no Programa de Assistência à Gestante Cardíaca, no período de 01/06/15 a 30/10/79, tomando-se por base a gravidez e a doença reumática como ponto comum a todas as pacientes. Os resultados obtidos nestas gestações estão baseados nos parâmetros a seguir relacionados: idade da paciente no início da gestação, número de gestações, paridade, diagnóstico clínico-cardiológico, tipo funcional segundo a \"New York Heart Association\", idade gestacional, eletrocardiograma, tipo de parto, peso do recém-nascido ao nascer e suas condições de saúde. As pacientes do grupo \"II\" ou cirúrgico foram divididas em três subgrupos a saber: cirúrgico \"1\" (submetidas a comissurotomia valvar); cirúrgico \"2\" (submetidas a implante de prótese valvar-metálica tipo Starr-Edwards; e cirúrgico \"3\" (submetida a implante de prótese biológica de dura-máter). Os filhos das gestantes do grupo \"II\" ou cirúrgico têm peso significativamente menor que os filhos das gestantes do grupo \"I\" ou clínico. Entre as pacientes dos subgrupos cirúrgicos os filhos das pacientes com prótese de Starr-Edwards têm peso menor do que os filhos das gestantes dos outros subgrupos cirúrgicos, o que pode, pelo menos em parte, ser explicado pela ação dos anticoagulantes orais. Em relação ao tipo funcional, as pacientes cardíacas reumáticas clínicas podem engravidar se estiverem classificadas nos tipos funcionais I e II da \"New York Heart Association\", enquanto que as do grupo cirúrgico, com qualquer tipo de procedimento cirúrgico anterior, só poderão engravidar se pertencerem ao tipo funcional I, sem história de descompensação cardíaca anterior. As pacientes com prótese de Starr-Edwards na vigência de anticoagulação oral, devem ser bem orientadas em relação aos riscos do uso de tal medicação e entrarem para o programa especial de acompanhamento, com emprego de heparina subcutânea, principalmente durante a organogênese e ao controle rigoroso do tempo de protrombina, para prevenir o aparecimento de fenômenos trómboembólicos e do síndrome warfarínico fetal. As pacientes com prótese de dura-máter aórtica devem ser desencorajadas a engravidar. O período ideal para uma gravidez em pacientes cardíacas reumáticas, após qualquer tipo de cirurgia cardíaca, é com duração superior a 1 ano e inferior a 6 anos de pós-operatório. O maior número de cesáreas foi uma constante em todos os grupos estudados e realizadas por indicação obstétrica. No cirúrgico \"2\" (ou com prótese de Starr-Edwards) há indicação relativa de parto programado devido ao uso de anticoagulantes orais. Os procedimentos cirúrgicos devem ser realizados preferentemente antes ou apÓs a gestação. Durante o período gestacional,a época teoricamente \"ideal\" é entre a 18a. e 24a. semanas de gestação, ou em qualquer fase da gestação quando este for um procedimento de urgência. A cardioversão elétrica, processo inócuo durante a gravidez pode ser realizado em qualquer período gestacional para reversão da fibrilação atrial a ritmo sinusal. A taxa de óbitos maternos nas 301 gestações estudadas foi de 1,66 por cento , sendo que houve diferença significativa entre as proporções de óbitos nos dois grupos \"I\" e \"II\". As perdas do produto conceptual foram significativamente menores no grupo \"I\" ou clínico (4,48 por cento ) do que no grupo \"II\" ou cirúrgico (12,39 por cento ). Os resultados obtidos permitiram melhor avaliação dos riscos cardiológico e gravídico, bem como possibilitaram a caracterização de diferentes parâmetros que, considerados em conjunto, serão fundamentais para a avaliação do prognóstico destas mulheres com cardiopatia reumática. / With a view to assessing the consequences of pregnancy in rheumatic heart patients this study considered two control groups: the clinical group (I) and the surgical group (II). All the rheumatic patients enrolled, during the period from June 1, 1975 to October 3 O, 1979, in the \"Programme of Assistance to the Cardiac pregnant Woman\" were included in this study. Pregnancy and rheumatic disease were the common factors in all the cases studied. The results obtained during these pregnancies are based on the following parameters: age of the patient at the beginning of pregnancy, number of pregnancies, parity, cardiological clinical diagnosis, functional type according to the \"New York Heart Association\", gestational age, electrocardiogram, type of birth, birth-weight and state of health of the babies. The patients of Group \"II\" (Surgical) were divided into three sub-groups, namely: Surgical \"1\" (composed of those who had undergone Valvotomy); Surgical \"2\" (who had undergone implant of the Starr-Edwards heart valve prosthesis) and Surgical \"3\" (who had undergone implant of the \"dura-mater\" allograft prosthesis). The children of the mothers of group II (Surgical) were found to be of considerably lower weight than the children of mothers of group I (Clinical). With regard to the patients of the surgical sub-groups, the children of those with Starr-Edwards prosthesis are of lower weight than the children of the patients of the other surgical sub-groups which can be accounted for, at least in some measure, as a result of the use of oral anticoagulants. With regard to the functional type, theclinical rheumatic heart patients may become pregnant if classified as of the functional types I and II of the \"New York Heart Association\", while those of the surgical group, with any kind of earlier surgical treatment, may only become pregnant if they belong to the functional type I, with no previous history of cardiac insufficiency. The patients with Starr-Edwards prosthesis must be fully advised about the risks of using oral anticoagulants and must be put onto a special assistance programme, with employment of intradermic heparin, especially during organogenesis. They must also be advised about the necessary rigorous control of the prothrombine time to guard against the appearance of thromboembolic problems and Warfarin embryopathy. Patients with aortic \"dura-mater\" prosthesis should be discouraged from becoming pregnant. The most favorable period for pregnancy in rheumatic heart patients with any kind of cardiac surgical history is that lasting from a minimum of one year to a maximum of six years after operation. A majority of births by ceasarean section was a constant in all groups studied these were carried out on the basis of the obstetrician\'s recommendation. In the surgical sub-group \"2\" (those with Starr-Edwards prosthesis) there is a relatively high probability of programm~d births due to the use of oral anticoagulants. Surgery ought to be carried out, preferably, either before of after pregnancy. During the period of pregnancy the theoretically ideal occasion for surgery is between the 18th and 24th. weeks of pregnancy or, at any time during the pregnancy in urgent cases. Electrical cardioversion is a harmless procedure for the expectant mother and may be carried out at any time during the pregnancy for the reversal of the atrial fibrilation to the sinus rhythm. The maternal death rate for the 301 pregnancies studied was of 1.66 per cent , though there was a significant difference between the proportion of deaths occuring in groups I and II. The loss of the conceptual product was significantly less in Group I (clinical) 4.48 per cent than in Group II (surgical) 12.39 per cent . The result obtained permitted a better assessment of the cardiological and pregnancy risks, as well as making possible the characterization of the different parameters which, considered as a group, will be fundamental to the assessment of the prognosis of women with rheumatic heart disease.
33

Avalia??o cl?nica de pacientes submetidos ? coloca??o de implantes zigom?ticos pela t?cnica de Stella & Warner

Ara?jo, Pryscyla Pascally Targino 19 December 2012 (has links)
Made available in DSpace on 2014-12-17T15:43:51Z (GMT). No. of bitstreams: 1 PryscylaPTA_DISSERT.pdf: 1471076 bytes, checksum: 63eee78ee148fad88e300caf30aa4256 (MD5) Previous issue date: 2012-12-19 / This study aimed to evaluate patients who underwent placement of zygomatic implants technique by Stella & Warner, considering the survival of conventional and zygomatic implants, sinus health and level of patient satisfaction in relation to oral rehabilitation. We evaluated 28 patients where 14 had received conventional and zygomatic implants, being rehabilitated with implant-fixed dentures (group 1) and 14 were rehabilitated only with conventional implants and implant-fixed dentures (group 2). The study had four phases, represented by radiographic evaluation of implants (stage I), clinical evaluation (stage II), assessing the health of the maxillary sinus (stage III) and a questionnaire to measure satisfaction of rehabilitation with fixed prosthesis implant Total -backed (stage IV). Group 2 underwent only stage IV, while group 1 participated in all stages. Descriptive analysis and statistics were performed, using the t test for independent samples in the evaluation of phase IV. The results demonstrated that the technique of Stella & Warner proved effective, allowing a high survival rate of conventional implants and zygomatic (100%), considering a minimum follow-up of 15 months and maximum 53 months after prosthetic rehabilitation. There were no pathological changes in tissues periimplants conventional and zygomatic implants analyzed. Radiographic findings showed satisfactory levels bone implants in the oral rehabilitation with conventional zygomatic implants and a good positioning of the apex of the zygomatic implants over the zygomatic bone. The presence of the zygomatic implant did not cause sinus and the t test showed a satisfaction index lower in group 1 compared with group 2. The zygomatic implant placement technique by Stella & Warner proved to be a predictable technique with high survival rate in patients with atrophic jaws, necessitating long-term follow-up to confirm the initial findings of the study / Este trabalho se prop?s a avaliar pacientes submetidos ? coloca??o de implantes zigom?ticos pela t?cnica de Stella & Warner, considerando a sobreviv?ncia dos implantes convencionais e zigom?ticos, a sa?de do seio maxilar e o n?vel de satisfa??o dos pacientes em rela??o ? reabilita??o oral. Foram avaliados 28 pacientes, onde 14 haviam recebido implantes zigom?ticos e convencionais, encontrando-se reabilitados com pr?teses totais fixas implantossuportadas (grupo 1) e 14 foram reabilitados somente com implantes convencionais e pr?teses totais fixas implantossuportadas (grupo 2). O estudo teve quatro fases, representadas pela avalia??o radiogr?fica dos implantes (fase I), avalia??o cl?nica (fase II), avalia??o da sa?de do seio maxilar (fase III) e aplica??o de um question?rio para mensurar a satisfa??o da reabilita??o com pr?tese fixa total implanto-suportada (fase IV). O grupo 2 s? foi submetido a fase IV, enquanto o grupo 1 participou de todas as etapas. Foram realizadas an?lises descritivas e estat?sticas, tendo, esta ?ltima, utilizado o test t para amostras independentes na avalia??o da fase IV. Os resultados demonstraram que a t?cnica de Stella & Warner mostrou-se efetiva, permitindo um elevado ?ndice de sobreviv?ncia dos implantes convencionais e zigom?ticos (100%), considerando um per?odo m?nimo de acompanhamento de 15 meses e m?ximo de 53 meses ap?s reabilita??o prot?tica. N?o foram encontradas altera??es patol?gicas nos tecidos periimplantares dos implantes convencionais e zigom?ticos analisados. Os achados radiogr?ficos mostraram n?veis ?sseos satisfat?rios nos implantes convencionais das reabilita??es orais com fixa??es zigom?ticas e um bom posicionamento do ?pice dos implantes zigom?ticos em rela??o ao osso zigom?tico. A presen?a do implante zigom?tico n?o provocou sinusopatias e o teste t demonstrou um ?ndice de satisfa??o inferior no grupo 1 quando comparado ao grupo 2. A coloca??o de implantes zigom?ticos pela t?cnica de Stella & Warner mostrou ser uma t?cnica previs?vel, com alto ?ndice de sobreviv?ncia em pacientes com maxilas atr?ficas, sendo necess?rio um acompanhamento por longo prazo para confirmar os achados iniciais desse estudo
34

A doença reumática no ciclo gravído-puerperal / Rheumatic disease in pregnancy and childbirth

Januario de Andrade 09 December 1981 (has links)
A fim de avaliar o resultado da gestação em pacientes cardíacas foram considerados dois grupos controle: o grupo \"I\" ou clínico e o grupo \"II\" ou cirúrgico. Foram considerados para este estudo todas as pacientes reumáticas matriculadas no Programa de Assistência à Gestante Cardíaca, no período de 01/06/15 a 30/10/79, tomando-se por base a gravidez e a doença reumática como ponto comum a todas as pacientes. Os resultados obtidos nestas gestações estão baseados nos parâmetros a seguir relacionados: idade da paciente no início da gestação, número de gestações, paridade, diagnóstico clínico-cardiológico, tipo funcional segundo a \"New York Heart Association\", idade gestacional, eletrocardiograma, tipo de parto, peso do recém-nascido ao nascer e suas condições de saúde. As pacientes do grupo \"II\" ou cirúrgico foram divididas em três subgrupos a saber: cirúrgico \"1\" (submetidas a comissurotomia valvar); cirúrgico \"2\" (submetidas a implante de prótese valvar-metálica tipo Starr-Edwards; e cirúrgico \"3\" (submetida a implante de prótese biológica de dura-máter). Os filhos das gestantes do grupo \"II\" ou cirúrgico têm peso significativamente menor que os filhos das gestantes do grupo \"I\" ou clínico. Entre as pacientes dos subgrupos cirúrgicos os filhos das pacientes com prótese de Starr-Edwards têm peso menor do que os filhos das gestantes dos outros subgrupos cirúrgicos, o que pode, pelo menos em parte, ser explicado pela ação dos anticoagulantes orais. Em relação ao tipo funcional, as pacientes cardíacas reumáticas clínicas podem engravidar se estiverem classificadas nos tipos funcionais I e II da \"New York Heart Association\", enquanto que as do grupo cirúrgico, com qualquer tipo de procedimento cirúrgico anterior, só poderão engravidar se pertencerem ao tipo funcional I, sem história de descompensação cardíaca anterior. As pacientes com prótese de Starr-Edwards na vigência de anticoagulação oral, devem ser bem orientadas em relação aos riscos do uso de tal medicação e entrarem para o programa especial de acompanhamento, com emprego de heparina subcutânea, principalmente durante a organogênese e ao controle rigoroso do tempo de protrombina, para prevenir o aparecimento de fenômenos trómboembólicos e do síndrome warfarínico fetal. As pacientes com prótese de dura-máter aórtica devem ser desencorajadas a engravidar. O período ideal para uma gravidez em pacientes cardíacas reumáticas, após qualquer tipo de cirurgia cardíaca, é com duração superior a 1 ano e inferior a 6 anos de pós-operatório. O maior número de cesáreas foi uma constante em todos os grupos estudados e realizadas por indicação obstétrica. No cirúrgico \"2\" (ou com prótese de Starr-Edwards) há indicação relativa de parto programado devido ao uso de anticoagulantes orais. Os procedimentos cirúrgicos devem ser realizados preferentemente antes ou apÓs a gestação. Durante o período gestacional,a época teoricamente \"ideal\" é entre a 18a. e 24a. semanas de gestação, ou em qualquer fase da gestação quando este for um procedimento de urgência. A cardioversão elétrica, processo inócuo durante a gravidez pode ser realizado em qualquer período gestacional para reversão da fibrilação atrial a ritmo sinusal. A taxa de óbitos maternos nas 301 gestações estudadas foi de 1,66 por cento , sendo que houve diferença significativa entre as proporções de óbitos nos dois grupos \"I\" e \"II\". As perdas do produto conceptual foram significativamente menores no grupo \"I\" ou clínico (4,48 por cento ) do que no grupo \"II\" ou cirúrgico (12,39 por cento ). Os resultados obtidos permitiram melhor avaliação dos riscos cardiológico e gravídico, bem como possibilitaram a caracterização de diferentes parâmetros que, considerados em conjunto, serão fundamentais para a avaliação do prognóstico destas mulheres com cardiopatia reumática. / With a view to assessing the consequences of pregnancy in rheumatic heart patients this study considered two control groups: the clinical group (I) and the surgical group (II). All the rheumatic patients enrolled, during the period from June 1, 1975 to October 3 O, 1979, in the \"Programme of Assistance to the Cardiac pregnant Woman\" were included in this study. Pregnancy and rheumatic disease were the common factors in all the cases studied. The results obtained during these pregnancies are based on the following parameters: age of the patient at the beginning of pregnancy, number of pregnancies, parity, cardiological clinical diagnosis, functional type according to the \"New York Heart Association\", gestational age, electrocardiogram, type of birth, birth-weight and state of health of the babies. The patients of Group \"II\" (Surgical) were divided into three sub-groups, namely: Surgical \"1\" (composed of those who had undergone Valvotomy); Surgical \"2\" (who had undergone implant of the Starr-Edwards heart valve prosthesis) and Surgical \"3\" (who had undergone implant of the \"dura-mater\" allograft prosthesis). The children of the mothers of group II (Surgical) were found to be of considerably lower weight than the children of mothers of group I (Clinical). With regard to the patients of the surgical sub-groups, the children of those with Starr-Edwards prosthesis are of lower weight than the children of the patients of the other surgical sub-groups which can be accounted for, at least in some measure, as a result of the use of oral anticoagulants. With regard to the functional type, theclinical rheumatic heart patients may become pregnant if classified as of the functional types I and II of the \"New York Heart Association\", while those of the surgical group, with any kind of earlier surgical treatment, may only become pregnant if they belong to the functional type I, with no previous history of cardiac insufficiency. The patients with Starr-Edwards prosthesis must be fully advised about the risks of using oral anticoagulants and must be put onto a special assistance programme, with employment of intradermic heparin, especially during organogenesis. They must also be advised about the necessary rigorous control of the prothrombine time to guard against the appearance of thromboembolic problems and Warfarin embryopathy. Patients with aortic \"dura-mater\" prosthesis should be discouraged from becoming pregnant. The most favorable period for pregnancy in rheumatic heart patients with any kind of cardiac surgical history is that lasting from a minimum of one year to a maximum of six years after operation. A majority of births by ceasarean section was a constant in all groups studied these were carried out on the basis of the obstetrician\'s recommendation. In the surgical sub-group \"2\" (those with Starr-Edwards prosthesis) there is a relatively high probability of programm~d births due to the use of oral anticoagulants. Surgery ought to be carried out, preferably, either before of after pregnancy. During the period of pregnancy the theoretically ideal occasion for surgery is between the 18th and 24th. weeks of pregnancy or, at any time during the pregnancy in urgent cases. Electrical cardioversion is a harmless procedure for the expectant mother and may be carried out at any time during the pregnancy for the reversal of the atrial fibrilation to the sinus rhythm. The maternal death rate for the 301 pregnancies studied was of 1.66 per cent , though there was a significant difference between the proportion of deaths occuring in groups I and II. The loss of the conceptual product was significantly less in Group I (clinical) 4.48 per cent than in Group II (surgical) 12.39 per cent . The result obtained permitted a better assessment of the cardiological and pregnancy risks, as well as making possible the characterization of the different parameters which, considered as a group, will be fundamental to the assessment of the prognosis of women with rheumatic heart disease.
35

Impact des tissus mous sur les méthodes acoustiques d’évaluation de la stabilité des implants osseux. / Impact of soft tissues on acoustic methods for the stability assessment of bone implants

Bosc, Romain 12 January 2018 (has links)
Ce travail porte sur l’étude du comportement biomécanique d’un modèle cadavérique et d’un modèle in vitro de l’arthroplastie totale de hanche. Nous avons cherché à mettre en relief et à étudier des paramètres qui pouvaient nous permettre de disposer d’une méthode d’analyse objective de la stabilité de l’implant acétabulaire. La première partie décrit le contexte de l'étude. Nous avons insisté sur les différentes méthodes d’analyses qui permettent d’analyser la stabilité d’un implant osseux. En effet, malgré l’utilisation quotidienne des implants, le taux d’échec d’ostéointégration reste élevé. Ces échecs s’accompagnent d’une morbidité importante et d’un surcout notable. Parmi les causes d’échec identifiées, le descellement aseptique de la cupule acétabulaire dans l’arthroplastie de hanche peut être lié à un défaut de stabilité primaire, non obtenu lors de l’intervention chirurgicale. Il a été montré que le descellement de la cupule acétabulaire pouvait résulter d'une faible stabilité primaire entre la cupule et l'os l'entourant. Les chirurgiens qui pratiquent l’arthroplastie de hanche évaluent de manière empirique la stabilité obtenue ou non de l’implant acétabulaire en écoutant le son produit lorsqu'ils impactent la cupule ou à leur ressenti en la manipulant. Une méthode d'estimation de la stabilité primaire pourrait permettre au chirurgien orthopédique de mieux appréhender la stabilité des implants qu’il pose au bloc opératoire. L'objet principal de ce travail de thèse était ainsi d'étudier les signaux d'impacts sur le cotyle prothétique. Dans un premier temps, nous avons réalisé une étude de l'insertion de la cupule par impacts sur un modèle cadavérique (sujets anatomiques de l’école de chirurgie du fer à moulin) dans des conditions proches de celle de l'opération en clinique. Une corrélation a été trouvée entre le moment d'impact et la stabilité (R2=0.69). Cette étude expérimentale a ainsi montré le potentiel de la méthode de traitement des signaux d'impact dans la prédiction de la stabilité primaire de la cupule acétabulaire. Mais nous avons observé des modifications entre les signaux obtenus sur les différents sujets. Nous avons posé comme hypothèse que ces modifications étaient liées à la variation des tissus mous entre chaque sujet. Le troisième volet de cette thèse a donc porté sur l’analyse du comportement biomécanique de notre modèle en présence d’une quantité plus ou moins importante de muscle.Nous avons utilisé à nouveau le modèle in vitro que nous avions développé et avons ajouté dans le système d’impaction des tranches de poitrine de dinde d’épaisseur variable. Le but de cette seconde étude était d’intégrer le paramètre lié à l’existence d’une épaisseur variable de tissus mous dans l'interaction dynamique entre le marteau, l'ancillaire (et la cupule) et le tissu osseux lors de l'insertion. La valeur de la moyenne et de l’écart-type de l'indicateur Im obtenues pour tous les échantillons et toutes les configurations pour une valeur d’épaisseur des tissus mous égale à 10 mm (respectivement 30 mm) étaient égales à 0,592 ± 0,141 (respectivement 0,552 ± 0,139). L’analyse statistique a montré qu'il n'y avait pas eu d'effet significatif de la valeur de l’épaisseur des tissus mous sur les valeurs de l'indicateur Im (F = 3,16; p = 0,08). Malgré les limitations évidentes d’une étude in vitro sur un modèle partiel d’arthroplastie totale de hanche, ces résultats, ainsi que les résultats précédents obtenus sur les sujets anatomiques, montrent la faisabilité du développement d'un dispositif médical dédié à l'estimation de la stabilité de l'implant acétabulaire et qui pourrait être utilisé comme système d'aide à la décision par le chirurgien orthopédique. / Abstract:This work studies the biomechanical behavior of a cadaveric model and an in vitro model of total hip arthroplasty. We sought to highlight and study parameters that could allow us to have a method of objective analysis of the stability of the acetabular cup implant.The first part describes the context of the study. We have emphasized the different methods of analysis that make it possible to analyse the stability of a bone implant. Indeed, despite the daily use of implants, the failure rate of osseointegration remains high and failures still happen due to inadequate mechanical behavior of the prosthesis.Among the identified causes of failure, aseptic loosening of the acetabular cup after hip arthroplasty may be related to a primary defect in stability, not achieved during the surgical procedure. It has been shown that loosening of the acetabular cup may result from poor primary stability between the prosthetic cup and the surrounding bone.A method of estimating primary stability could allow the orthopaedic surgeon to better control the stability of the implants he poses in the operating room.The main purpose of this thesis work was to study the impact signals on the prosthetic acetabulum.Firstly, we carried out a study of the insertion of the cup by impacts on a cadaveric model. A correlation was found between impact time and stability (R2 = 0.69). This experimental study has thus shown the potential of the impact signal processing method in predicting the primary stability of the acetabular cup. But we observed changes between the signals obtained on the different subjects. We hypothesized that these changes were related to soft tissue variation between subjects.The third part of this thesis focused on analysing the biomechanical behavior of our model in the presence of soft tissues.We used again the in vitro model that we had developed and added in the impaction system turkey slices of varying thickness.The purpose of this second study was to integrate the parameter related to the existence of a variable thickness of soft tissues in the dynamic interaction between the hammer, the ancillary (and the cup) and the bone tissue during the insertion. The mean and standard deviation of the Im indicator obtained for all samples and configurations at a soft tissue thickness value of 10 mm (30 mm) was 0.592 ± 0.141, (respectively 0.552 ± 0.139). Statistical analysis showed that there was no significant effect of the value of soft tissue thickness on the values of the Im indicator (F = 3.16, p = 0.08). Despite the obvious limitations of an in vitro study on a partial model of total hip arthroplasty, these results, as well as the previous results obtained on anatomical subjects, show the feasibility of developing a medical device dedicated to estimating the stability of the acetabular implant and which could be used as a decision support system by the orthopaedic surgeons.
36

Estudo das tensões em dente restaurado com coroa metalocerâmica e dois formatos de retentores intra-radiculares - método dos elementos finitos. / Finite element analysis of a endodontically treated teeth restored with two different types of post and core systems.

Rocha, Isaac José Peixoto Batinga da 06 November 2000 (has links)
O estudo comparativo da distribuição de tensões de von Mises em dente endodonticamente tratado, com dois formatos de retentores intra-radiculares, pré-fabricado cilíndrico/escalonado e fundido cônico, foi realizado pelo método dos elementos finitos em modelos tridimensionais de caninos superiores com geometria axi-simétrica e restaurados com coroas metalocerâmicas, aplicando-se uma carga oblíqua de 100N com 45 º de inclinação em relação ao seu longo eixo. Os resultados indicaram uma discreta diferença nos dois modelos (formatos) de retentores. O pino escalonado neutralizou mais as cargas no sentido corono-apical e no pino cônico ficou evidenciado o efeito de cunha. / The aim of this study was to compare the von Mises stress distribution on a human canine teeth endodontically treated and restored with two types of post and core. The analysis was made using the three dimensional Finite Element Analysis method. For the analysis was created and axy-simetric structure of the teeth, including a porcelain fused to metal crown, a cement layer, and the periodontal structures. The model was analyzed when a 100N load was applied on the surface of the crown with 45º angulation with the long axis of the teeth. The results showed that both models exhibit little difference, the “stair shape" post system neutralized the axial loads, and the conical shape post showed a wedge effect on the apical third of the root.
37

Análise por meio de elementos finitos tridimensionais da distribuição de tensões no osso adjacente aos orifícios e implantes em mandíbulas com três níveis de reabsorção e prótese mucosa-suportada / Three-dimensional finite element analysis to study transmission and stress distribution in the bone adjacent to the perforation and implants in mandibles with three levels of resorption and muco-supported dental prothesis

Lima, João Henrique Ferreira 23 February 2015 (has links)
Tensão elevada no osso pode provocar reabsorção óssea. O objetivo deste estudo é avaliar por meio do método dos elementos finitos tridimensionais as áreas de concentração de tensões no osso basal após realização dos orifícios para inserção dos implantes e com implantes osseointegrados, em mandíbulas com três níveis de reabsorção e prótese mucosa-suportada. Foram confeccionados 7 modelos por meio do software de CAD: Rhinoceros 4.0 SR9; 1 (controle)- mandíbula com 15mm de altura e sem orifício; 2- mandíbula com 15mm de altura e 2 orifícios de 3,75mm de diâmetro; 3- mandíbula com 15mm e 2 implantes osseointegrados; 4- mandíbula com 20mm e 2 orifícios; 5- mandíbula com 20mm e 2 implantes osseointegrados 6- mandíbula com 26mm e 2 orifícios e 7- mandíbula com 26mm e 2 implantes osseointegrados. A força aplicada foi de 60N no sentido axial, nos dentes artificiais da prótese removível total reembasada com 2mm de material macio. Após a discretização dos modelos foi realizado o ensaio pelo método dos elementos finitos por meio do Software NEiNastran for Windows Version 10.0.3.997. Os resultados evidenciaram aumento da tensão no osso cortical em relação ao medular. Mandíbulas sem perfuração apresentaram picos de tensão mais elevados que as com implantes osseointegrados. Nas mandíbulas com orifícos os picos de tensão se localizaram no sentido vestíbulo-lingual enquanto nas com implantes esses picos de tensão foram no sentido mésio-distal. Quanto mais reabsorvida a mandíbula maior a tensão transmitida pela base da prótese removível total ao orifício. Conclui-se que as mandíbulas com 15 e 20 mm de altura com orifícios apresentaram maiores picos de tensão que as com implantes osseointegrados, enquanto nas com 26mm de altura não houve diferença entre ambas condições / Increased pressure in the bone can cause resorption. The purpose of this study is to evaluate areas of stress concentration in the basal mandibular bone after perforation for inserting the implants and dental implants in mandibles with three levels of resorption and muco-supported dental prosthesis using the three-dimensional finite element method. 7 models were produced through CAD software: Rhinoceros 4.0 SR9; 1 (control) -15mm jaw height and without perforation; 2- 15mm jaw height and two perforations of 3.75 mm in diameter; 3- 15mm jaw height with 2 osseointegrated dental implants; 4- 20mm jaw height and 2 perforations; 5- 20mm jaw heigth with two osseointegrated dental implants; 6- 26mm jaw height and two perforation; and 7- 26mm jaw height with two osseointegrated dental implants. The force of 60N was applied in the axial direction to the artificial teeth denture provisional recover with 2mm soft material for edentolous tissue conditioner. After discretization of the test models it was performed a trial using the finite element method through NEiNastran Software for Windows Version 10.0.3.997. The results showed increased tension in cortical bone in relation to the medular bone. Mandibles without perforation showed stress peaks higher than those with dental implants. In the jaws with drilling the stress peaks were located in the buccal-lingual direction while in those with implant they were in the mesial-distal direction. The more resorbed jaw greater the tension transmitted by the base of full removable denture to the drilling. The study concluded that the jaws 15 and 20 mm height perforated had higher stress peaks than the ones with dental implants while in the 26mm height perforated no difference between the two conditions was observed
38

Avaliação da tensão gerada em intermediários e região peri-implantar simulada após aperto de parafusos para fixação de infraestruturas confeccionadas por duas técnicas CAD/CAM e convencional / Evaluation of strain generated in abutments and peri-implant simulated region after tightening screws on frameworks made by conventional and two CAD/CAM techniques

Braga, Adriana de Castro Oliveira Pereira 27 August 2013 (has links)
A passividade tem sido descrita como um requisito importante para a longevidade de restaurações implanto-suportadas e, na busca incessante por materiais e técnicas que desempenhem um melhor resultado biomecânico para este tipo restauração, surgem os métodos baseados em desenho e manufatura auxiliados por computador, os chamados métodos CAD/CAM. Assim, o objetivo deste estudo foi comparar o desenvolvimento de tensão provocado pela fixação, por meio do aperto de parafusos, de infraestruturas confeccionadas por duas técnicas CAD/CAM e pela técnica convencional da cera perdida. Para a realização do experimento, foi confeccionado um modelo em poliuretano com dois implantes hexágono externo posicionados nas áreas dos dentes 43 e 45. A partir deste modelo, 12 infraestruturas de três elementos foram fabricadas e divididas em 3 grupos (n=4) de acordo com a técnica utilizada: (C) infraestruturas em Ni-Cr fundidas pela técnica convencional da cera perdida; (U) infraestruturas em zircônia confeccionadas pela técnica CAD/CAM de usinagem e (S) infraestruturas em Co-Cr confeccionadas pela técnica CAD/CAM de sinterização a laser. Durante o aperto dos parafusos para fixação das infraestruturas, as tensões geradas foram registradas por extensômetros unidos aos intermediários e material de osso simulado. De acordo com a técnica utilizada e considerando todos os diferentes locais avaliados, os valores médios de tensão variaram de: 14,28 μξ a 693,40 μξ para o Grupo C; 19,27 μξ a 930,92 μξ para o Grupo U e 5,37 μξ a 196,57 μξ para o Grupo S. Análise de variância a dois critérios para as variáveis técnica de confecção de infraestruturas e local de avaliação da tensão demonstrou que não houve diferença estatisticamente significante entre os valores de tensão em relação à técnica utilizada. Por outro lado, os valores foram significantemente diferentes em relação aos diferentes locais analisados. Desta forma, este estudo concluiu que as duas técnicas CAD/CAM testadas não proporcionaram infraestruturas com passividade superior às obtidas convencionalmente e que todas as peças apresentaram certo grau de desadaptação e consequente falta de homogeneidade na distribuição de tensões pelo sistema. / Passivity property has been described as an important requirement for the longevity of implant-supported restorations. Looking for materials and techniques that provide better biomechanical outcome for such restorations, methods based on design and computer aided manufacturing has emerged, the called CAD/CAM techniques. Therefore, the aim of this study was to compare the strain development during tightening screws on frameworks made from two CAD/CAM techniques and conventional lost wax technique. For the experiment, a polyurethane model with two external hexagon implants, placed at 43 and 45 teeth areas, was made. From this model, 12 three-unit frameworks were produced and divided into 3 groups (n = 4) according to the technique used: (C) Ni-Cr cast frameworks produced by lost wax conventional technique; (U) zirconia frameworks prepared by CAD/CAM milling technique and (S) Co-Cr frameworks prepared by CAD/CAM laser sintering technique. Generated strains, during tightening screws, were recorded by strain gauges attached to abutments and simulated bone material. According to the technique used, which considered, all different sites evaluated, mean strain values ranged from: 14,28 μξ to 693,40 μξ for Group C; 19,27 μξ to 930,92 μξ for Group U and 5,37 μξ to 196.57 μξ for Group S. Two way ANOVA performed for frameworks technique and strain sites demonstrated no statistically significant difference between strain values in relation to the technique used. On the other hand, values were statistically different for distinct sites analyzed. Furthermore, this study concluded that the two CAD/CAM techniques tested did not provide frameworks with better passivity than conventionally obtained ones and that all parts showed some degree of mismatch and consequent lack of homogeneity related to stresses distribution through the system.
39

Análise por meio de elementos finitos tridimensionais da distribuição de tensões no osso adjacente aos orifícios e implantes em mandíbulas com três níveis de reabsorção e prótese mucosa-suportada / Three-dimensional finite element analysis to study transmission and stress distribution in the bone adjacent to the perforation and implants in mandibles with three levels of resorption and muco-supported dental prothesis

João Henrique Ferreira Lima 23 February 2015 (has links)
Tensão elevada no osso pode provocar reabsorção óssea. O objetivo deste estudo é avaliar por meio do método dos elementos finitos tridimensionais as áreas de concentração de tensões no osso basal após realização dos orifícios para inserção dos implantes e com implantes osseointegrados, em mandíbulas com três níveis de reabsorção e prótese mucosa-suportada. Foram confeccionados 7 modelos por meio do software de CAD: Rhinoceros 4.0 SR9; 1 (controle)- mandíbula com 15mm de altura e sem orifício; 2- mandíbula com 15mm de altura e 2 orifícios de 3,75mm de diâmetro; 3- mandíbula com 15mm e 2 implantes osseointegrados; 4- mandíbula com 20mm e 2 orifícios; 5- mandíbula com 20mm e 2 implantes osseointegrados 6- mandíbula com 26mm e 2 orifícios e 7- mandíbula com 26mm e 2 implantes osseointegrados. A força aplicada foi de 60N no sentido axial, nos dentes artificiais da prótese removível total reembasada com 2mm de material macio. Após a discretização dos modelos foi realizado o ensaio pelo método dos elementos finitos por meio do Software NEiNastran for Windows Version 10.0.3.997. Os resultados evidenciaram aumento da tensão no osso cortical em relação ao medular. Mandíbulas sem perfuração apresentaram picos de tensão mais elevados que as com implantes osseointegrados. Nas mandíbulas com orifícos os picos de tensão se localizaram no sentido vestíbulo-lingual enquanto nas com implantes esses picos de tensão foram no sentido mésio-distal. Quanto mais reabsorvida a mandíbula maior a tensão transmitida pela base da prótese removível total ao orifício. Conclui-se que as mandíbulas com 15 e 20 mm de altura com orifícios apresentaram maiores picos de tensão que as com implantes osseointegrados, enquanto nas com 26mm de altura não houve diferença entre ambas condições / Increased pressure in the bone can cause resorption. The purpose of this study is to evaluate areas of stress concentration in the basal mandibular bone after perforation for inserting the implants and dental implants in mandibles with three levels of resorption and muco-supported dental prosthesis using the three-dimensional finite element method. 7 models were produced through CAD software: Rhinoceros 4.0 SR9; 1 (control) -15mm jaw height and without perforation; 2- 15mm jaw height and two perforations of 3.75 mm in diameter; 3- 15mm jaw height with 2 osseointegrated dental implants; 4- 20mm jaw height and 2 perforations; 5- 20mm jaw heigth with two osseointegrated dental implants; 6- 26mm jaw height and two perforation; and 7- 26mm jaw height with two osseointegrated dental implants. The force of 60N was applied in the axial direction to the artificial teeth denture provisional recover with 2mm soft material for edentolous tissue conditioner. After discretization of the test models it was performed a trial using the finite element method through NEiNastran Software for Windows Version 10.0.3.997. The results showed increased tension in cortical bone in relation to the medular bone. Mandibles without perforation showed stress peaks higher than those with dental implants. In the jaws with drilling the stress peaks were located in the buccal-lingual direction while in those with implant they were in the mesial-distal direction. The more resorbed jaw greater the tension transmitted by the base of full removable denture to the drilling. The study concluded that the jaws 15 and 20 mm height perforated had higher stress peaks than the ones with dental implants while in the 26mm height perforated no difference between the two conditions was observed
40

Sobrevida de implantes submetidos à carga funcional imediata na região interforaminal através do uso de anéis de retenção isolados em uma prótese total removível / Survival rates of implants submited to immediate funcional load in the interforaminal region using retention rings on a removable complete denture

Renato da Silva Fraga 12 March 2009 (has links)
O presente trabalho teve como objetivo comparar clinicamente através da taxa de sobrevida e análise de freqüência de ressonância, dois implantes instalados na região anterior da mandíbula, submetidos à carga funcional imediatamente a instalação dos implantes, através de anéis de retenção isolados presos a uma sobredentadura, com um implante instalado na mesma região, livre de carga funcional. Com este objetivo, onze pacientes foram selecionados para instalação de três implantes osteointegráveis em cada, sendo o implante livre de cargas funcionais utilizado como grupo controle. Através dos resultados obtidos, dos vinte e dois implantes submetidos à carga funcional imediata, dois foram perdidos, apresentando uma taxa de sobrevida proporcional a amostra de 93.9%. Quanto ao grupo controle, nenhum implante foi perdido. Após 4 anos de controle clínico, todos os implantes apresentam-se osteointegrados. / The present study aimed to clinically compare through resonance frequency analysis and survival rate, one implant installed in the mandibular anterior region, free from functional load, with two implants installed in the same region, submitted to immediate functional load through isolated retention rings attached to an overdenture. With this purpose, eleven patients were selected for installation of three implants in each. The implants free from functional load were used as the control group. Through the obtained results, two implants of the twenty-two implants submitted to immediate functional load were lost, representing a survival rate of 93.9%. As for the control group, no implants were lost. After 4 years of clinical control all implants remained integrated.

Page generated in 0.0611 seconds