• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 32
  • 3
  • 3
  • 3
  • 1
  • 1
  • Tagged with
  • 48
  • 27
  • 18
  • 13
  • 12
  • 12
  • 7
  • 6
  • 5
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Estudo dos parâmetros de estabilidade de travamento entre implante dentário e componente protético através do sistema cone Morse / Study on the stability parameters of locking between dental implants and prosthetic component system through the Morse taper

ARANHA, LUIS C. 28 October 2015 (has links)
Submitted by Claudinei Pracidelli (cpracide@ipen.br) on 2015-10-28T11:29:54Z No. of bitstreams: 0 / Made available in DSpace on 2015-10-28T11:29:54Z (GMT). No. of bitstreams: 0 / Tese (Doutorado em Tecnologia Nuclear) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
22

Análise in vitro da precisão de técnicas de esplintagem na moldagem de implantes no esquema all-on-four / In vitro analysis of the accuracy of splinting impression techniques using all-on-four system

Pimentel, Gustavo Henrique Diniz [UNESP] 15 October 2014 (has links) (PDF)
Made available in DSpace on 2016-12-09T13:52:22Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-10-15. Added 1 bitstream(s) on 2016-12-09T13:55:26Z : No. of bitstreams: 1 000874738.pdf: 3429941 bytes, checksum: f0746f3294aca82e94682f551d6b7ae5 (MD5) / O assentamento passivo de próteses sobre implantes é fundamental para que o sucesso da reabilitação seja alcançado. A precisão na moldagem de transferência é um dos principais fatores responsáveis por assegurar a adaptação dos componentes. Dentre as várias técnicas propostas, não existe consenso sobre qual é a mais eficaz. O objetivo do presente estudo foi avaliar in vitro a precisão de diferentes métodos de união de transferentes quadrados na moldagem de implantes paralelos e angulados instalados em curva. Para a obtenção do modelo mestre, matrizes metálicas em alumínio foram confeccionadas, apresentando quatro perfurações, em forma de curva, paralelas (prótese protocolo convencional) e anguladas (esquema All-on-four). Foram fixados os análogos e, sobre eles, foram confeccionadas estruturas metálicas. Para os implantes retos, os grupos foram divididos em GSU-R: transferentes quadrados sem união; GUR-R: transferentes quadrados unidos com bastões de resina acrílica autopolimerizável pré-fabricados e GUM-R: transferentes quadrados unidos com haste metálica, cianoacrilato e resina acrílica autopolimerizável. Para os implantes angulados, as mesmas técnicas foram comparadas: GSU-A, GUR-A, GUM-A. A moldagem foi realizada com silicone de adição e moldeira rosqueada para controlar variáveis. Os modelos foram vazados em matriz padronizada com gesso pedra tipo IV. Os modelos obtidos foram armazenados à temperatura ambiente por no mínimo 120 horas até que as medidas das fendas fossem realizadas. Foi utilizada uma lupa LEICA acoplada a uma câmera de vídeo colorida e as mensurações das fendas foram realizadas no programa LEICA QWin. Foi aplicado o teste de Kruskal-Wallis, complementando pelo teste de Dunn, com nível de significância de 5%. Para os implantes retos, foi observada diferença estatisticamente significante entre os grupos...(Resumo completo, clicar acesso eletrônico abaixo) / Passively fitting superstructures are a prerequisite for long-lasting osseointegration of dental implants. Accurate transfer of the implant positions from the mouth to a definitive stone cast is a crucial step for ensuring the adaptation of components. Among the various techniques proposed, there is no consensus on which one is the most effective. The aim of this study was to evaluate in vitro the accuracy of different splinting methods in the impression of implants under standardized laboratory conditions. To obtain the master model, an aluminum metal matrix was developed, presenting four perforations, parallel (simulating conventional prosthesis and angled (simulating All-on-four system). Analogs were fixed and, on them, metal structures were fabricated. For straight implants, the groups were divided into GSUR: non-splinted square transfers; GUR-R: transfers splinted acrylic resin; GUM R: transfers splinted with metal rod, cyanoacrylate and acrylic resin. For angled implants, the same techniques were compared: GSU-A, GUR-A, GUM-A. The impression was performed with polyvinyl siloxane impression material and a standardized tray to control variables. The models were cast in standardized matrix with type IV plaster stone. For the measurements, a software (Leica QWin) received the images from a video camera coupled to a Leica stereomicroscope. The KruskalWallis test, associated with Dunn's test, with significance level of 5%, was applied. For straight implants, statistically significant difference between groups (KruskalWallis test; p <0.001) was observed. The difference was between GUR-R (186.71 µm) and master model (110.40 µm) and between GUR-R and the other groups (GSU-R: 108.27 µm and GUM-R: 92.98 µm). For angled implants, no statistically significant difference (p = 0.492) was found between the groups (MM-A: 68.52 µm; GSU-A: 60.80 µm; GUR-A: 56.54 µm; GUM-A: 69.33 µm. ..(Complete abstract electronic access below)
23

Tenacidade à fratura e dureza de porcelana feldspática adicionada de óxido de zircônio : efeito da concentração e da temperatura de sinterização /

Ribeiro, João Gustavo Rabelo. January 2009 (has links)
Resumo: O objetivo deste estudo foi avaliar o efeito da adição de óxido de zircônio, em diferentes concentrações e temperaturas de sinterização, na tenacidade à fratura (KIC) e na dureza Vickers (HV) da porcelana feldspática Duceragold. Foram confeccionados discos cerâmicos (9,0 x 3,0mm; n=10) para os grupos: (G1) Duceragold sem adição de ZrO2, (G2) Duceragold adicionada de 1% de ZrO2, (G3) 2% de ZrO2, (G4) 3% de ZrO2, (G5) 4% de ZrO2, (G6) 5% de ZrO2, (G7) 6% de ZrO2 e (G8) 7% de ZrO2, sinterizados a: (a) 800 ºC, (b) 850 ºC, (c) 900 ºC, (d) 950 ºC e (e) 1000 ºC, totalizando 400 corpos-de-prova. Após a sinterização, em forno Alumini Press, procedeu-se sua inclusão e polimento até lixa 1500 em politriz. A HV foi mensurada em durômetro Buelher, com carga de 9,8 N, por 20 segundos; as imagens obtidas foram capturadas por meio de câmera JVC e os cálculos de KIC, executados com auxílio do software Laica. Para observação da superfície das amostras, foram realizadas fotomicrografias por MEV. Os resultados de KIC e HV foram submetidos a ANOVA e teste de Tukey (p!0,05). Observou-se que, independentemente da temperatura de sinterização, o aumento da concentração de óxido de zircônio, aumenta o KIC, todavia, a partir de 6%, a HV diminui; independentemente da concentração, o aumento da temperatura de sinterização proporciona aumento dos valores de HV, contudo, temperaturas de 950ºC e 1000ºC diminuem o KIC; com o aumento da concentração de óxido de zircônio e da temperatura de sinterização, aumentam o número de poros tanto na fase vítrea da porcelana, quanto na fase dispersa de zircônia. Considerando as propriedades estudadas e a caracterização da superfície, pode-se observar que as amostras com adição de até 4% de óxido de zircônio à porcelana feldspática Duceragold, sinterizadas em temperaturas de até 900ºC apresentam-se como as mais promissoras. / Abstract: The objective of this study was to evaluate the effect of adding zirconium oxide at different concentrations and temperatures of sintering, on the fracture toughness (KIC) and Vickers hardness (HV) of feldspathic porcelain Duceragold. Ceramic discs were prepared (9.0 x 3.0 mm, n = 10) for the groups: (G1) Duceragold without the addition of ZrO2, (G2) Duceragold added 1% of ZrO2, (G3) 2% of ZrO2, (G4) 3% of ZrO2, (G5) 4% of ZrO2, (G6) 5% of ZrO2, (G7) 6% of ZrO2 and (G8) 7% of ZrO2, sintered at: (a) 800 ºC, (b) 850 ºC, (c) 900 ºC, (d) 950 °C and (e) 1000 ºC, totaling 400 specimens of the samples. After sintering at Alumini Press furnace, inclusion and polishing by sandpaper polishing (# 1500) were proceeded. The HV was measured in a Buelher durometer, with a load of 9.8 N for 20 seconds, the images were captured using a JVC camera and calculation of KIC, performed with the aid of software Laica. To observe the surface of the samples were performed by SEM photomicrographs. The results of KIC and HV were submitted to ANOVA and Tukey's test (p ! 0.05). It was observed that regardless of sintering temperature, the concentration of zirconium oxide, increases the KIC, however, from 6%, HV decreases; regardless of the concentration, the increase of sintering temperature gives increased HV values, however, temperatures of 950 °C and 1000 °C decrease the KIC; with increasing concentration of zirconium oxide and sintering temperature, increase the number of pores in the vitreous and dispersed phase of zirconia. Considering the studied properties and characterization of the surface can be observed that the samples with the addition of up to 4% zirconium oxide in Duceragold feldspathic porcelain, sintered at temperatures up to 900 º C are presented as the most promising. / Orientador: Carlos Alberto dos Santos Cruz / Coorientador: José Cláudio Martins Segalla / Banca: Paulo Henrique dos Santos / Banca: Marcos Ribeiro Moysés / Banca: João Neudenir Arioli Filho / Banca: Renata Garcia Fonseca / Doutor
24

Análise in vitro da precisão de técnicas de esplintagem na moldagem de implantes no esquema all-on-four /

Pimentel, Gustavo Henrique Diniz. January 2014 (has links)
Orientador: Francisco de Assis Mollo Junior / Banca: Marco Antônio Compagnoni / Banca: Janaína Habib Jorge / Banca: Estevam Augusto Bonfante / Banca: Ricardo Faria Ribeiro / Resumo: O assentamento passivo de próteses sobre implantes é fundamental para que o sucesso da reabilitação seja alcançado. A precisão na moldagem de transferência é um dos principais fatores responsáveis por assegurar a adaptação dos componentes. Dentre as várias técnicas propostas, não existe consenso sobre qual é a mais eficaz. O objetivo do presente estudo foi avaliar "in vitro" a precisão de diferentes métodos de união de transferentes quadrados na moldagem de implantes paralelos e angulados instalados em curva. Para a obtenção do modelo mestre, matrizes metálicas em alumínio foram confeccionadas, apresentando quatro perfurações, em forma de curva, paralelas (prótese protocolo convencional) e anguladas (esquema "All-on-four"). Foram fixados os análogos e, sobre eles, foram confeccionadas estruturas metálicas. Para os implantes retos, os grupos foram divididos em GSU-R: transferentes quadrados sem união; GUR-R: transferentes quadrados unidos com bastões de resina acrílica autopolimerizável pré-fabricados e GUM-R: transferentes quadrados unidos com haste metálica, cianoacrilato e resina acrílica autopolimerizável. Para os implantes angulados, as mesmas técnicas foram comparadas: GSU-A, GUR-A, GUM-A. A moldagem foi realizada com silicone de adição e moldeira rosqueada para controlar variáveis. Os modelos foram vazados em matriz padronizada com gesso pedra tipo IV. Os modelos obtidos foram armazenados à temperatura ambiente por no mínimo 120 horas até que as medidas das fendas fossem realizadas. Foi utilizada uma lupa LEICA acoplada a uma câmera de vídeo colorida e as mensurações das fendas foram realizadas no programa LEICA QWin. Foi aplicado o teste de Kruskal-Wallis, complementando pelo teste de Dunn, com nível de significância de 5%. Para os implantes retos, foi observada diferença estatisticamente significante entre os grupos...(Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Passively fitting superstructures are a prerequisite for long-lasting osseointegration of dental implants. Accurate transfer of the implant positions from the mouth to a definitive stone cast is a crucial step for ensuring the adaptation of components. Among the various techniques proposed, there is no consensus on which one is the most effective. The aim of this study was to evaluate "in vitro" the accuracy of different splinting methods in the impression of implants under standardized laboratory conditions. To obtain the master model, an aluminum metal matrix was developed, presenting four perforations, parallel (simulating conventional prosthesis and angled (simulating "All-on-four" system). Analogs were fixed and, on them, metal structures were fabricated. For straight implants, the groups were divided into GSUR: non-splinted square transfers; GUR-R: transfers splinted acrylic resin; GUM R: transfers splinted with metal rod, cyanoacrylate and acrylic resin. For angled implants, the same techniques were compared: GSU-A, GUR-A, GUM-A. The impression was performed with polyvinyl siloxane impression material and a standardized tray to control variables. The models were cast in standardized matrix with type IV plaster stone. For the measurements, a software (Leica QWin) received the images from a video camera coupled to a Leica stereomicroscope. The KruskalWallis test, associated with Dunn's test, with significance level of 5%, was applied. For straight implants, statistically significant difference between groups (KruskalWallis test; p <0.001) was observed. The difference was between GUR-R (186.71 µm) and master model (110.40 µm) and between GUR-R and the other groups (GSU-R: 108.27 µm and GUM-R: 92.98 µm). For angled implants, no statistically significant difference (p = 0.492) was found between the groups (MM-A: 68.52 µm; GSU-A: 60.80 µm; GUR-A: 56.54 µm; GUM-A: 69.33 µm. ..(Complete abstract electronic access below) / Doutor
25

Aspectos relacionados ao tempo de duração de trabalhos protéticos à luz da reparação de danos / Aspects related to the term of prosthetic work to damage repair

Fernandes, Mário Marques 08 February 2010 (has links)
Orientador: Eduardo Daruge Júnior / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-16T11:53:01Z (GMT). No. of bitstreams: 1 Fernandes_MarioMarques_M.pdf: 1226077 bytes, checksum: 97df8894df2b17248ffd415071265aba (MD5) Previous issue date: 2010 / Resumo: Na área clínica pericial a odontologia legal se depara com a necessidade de avaliar qual seria o tempo de duração de trabalhos odontológicos proféticos, observando-se na literatura uma falta de padronização desse período. Não existe consenso também sobre as características dos trabalhos quanto ao quesito qualidade, bem como em relação ao tempo de guarda dos prontuários. Em vista destes dados o presente estudo buscou: a) verificar o grau de conhecimento do Cirurgião-dentista especialista em prótese dentária da Cidade de Porto Alegre/RS sobre aspectos relacionados ao tempo de duração de trabalhos protéticos, b) destacar o saber dos protesistas sobre legislação aplicada no exercício profissional e nas relações com a reparação de danos envolvendo trabalhos de prótese, e c) evidenciar os aspectos clínicos pertinentes ao tema. O presente estudo, após aprovado pelo Comitê de Ética e Pesquisa sob protocolo 118/2007, foi realizado por meio de questionários entregues nos 222 consultórios constantes na listagem fornecida pelo CRORS, pessoalmente e via correios. A amostra pesquisada constituiu-se de 143 questionários respondidos (n=143), ou seja, 64,4% do número de profissionais existentes a época. Quanto ao perfil dos pesquisados, verificou-se que 53,8% (n=77) eram do sexo feminino, a maioria 29,4% (n=42) dos profissionais respondentes se encontrava na idade entre 31 e 40 anos. O setor de trabalho que mais se destacou foi o particular, representando 53,8% (n=77). Já no que se refere ao tempo de exercício profissional, foi mais prevalente o período entre 16 e 20 anos, com 19,6 % (n=28). Quanto ao conhecimento sobre odontologia legal, 47,6% (n=68) dos questionados declararam não ter tido ministrados conteúdos relativos a essa área. Nos cruzamentos estatísticos, mostrou-se significativo a associação do conhecimento sobre o tempo de duração das reabilitações e o setor de trabalho dos protesistas (p=0, 002). Concluiu-se que: a) Existe entre os especialistas em prótese dentária da Cidade de Porto Alegre um conhecimento adequado sobre os aspectos relacionados ao tempo de duração de trabalhos de prótese; b) a maioria dos protesistas não foi instruída em odontologia legal e desconhece, de forma consistente, as normas éticas e legais pertinentes a profissão, bem como a legislação relacionada à reparação de danos envolvendo trabalhos reabilitadores de prótese; e c) pela necessidade de entendimento dos aspectos clínicos envolvidos na avaliação dos trabalhos de prótese (independente do tipo), a perícia para verificação da culpa deverá ser realizada por um Cirurgião-dentista odontolegista e com experiência irrefutável na área de prótese dentária. O período estimado sobre a duração dos trabalhos, quando avaliado em perícias odontolegais deve ser verificado com base nas responsabilidades de cada um dos envolvidos no trabalho: protesista, paciente e laboratório, atribuindo as reabilitações protéticas uma obrigação de meio / Abstract: In the examination clinical area, forensic dentistry faces the necessity of evaluating which would the prothetic dentistry work duration be, observing a lack of standard in literature, concerning time. There isn't any consensus about work features concerning quality neither in relation to how long the patient's records are kept. In view of these data, the current study aimed to: check the dentist's (CD) level of knowledge, specialized in dental prothesis in the city of Porto Alegre/RS on aspects linked to the duration of prothetic work, b) highlight the prothesist's knowledge on the law applied to the job and to relations with damage repairs involving prothesis; and c) evidence clinical aspects connected to the theme. The current study, after having been aproved by the Ethics and Research Commitee, protocol 118/2007, was performed through questionnaires delivered at the 222 offices from the list given by CRORS, personally and mainly by mail. The research sample had 143 questionnaires answered (n=143), in other words, 64,4% of professionals then. Regarding the respondents profile, it was found that 53,8% (n=77) were female, most of professionals who responded 29,4% (n=42) were between 31 and 40 years old. The work sector that mostly highlighted itself was the private one, representing 53,8% (n=77). Refering to professional time experience, it was most important the period between 16 and 20 years, 19,6 % (n=28). In terms of forensic odontology knowledge, 47,6%(n=68) of respondents said contents about the area had not been provided. When crossing the statistics, it was important the association of knowledge over lasting time rehabilitation and the prothesist working sector. (p=0,002). In conclusion: a) There is an adequate knowledge on the time a prothesis work lasts among the dentists specialized in dental prothesis in the city of Porto Alegre b) most of prothesists were not skilled in Legal Odontology and are not aware, in a large scale, of ethical and legal rules of the profession, as well as the law related to damage repairs, concerning prothesis rehabilitation work; and c) By the need for understanding clinical aspects involved in the evaluation of prothesis work (regardless the kind of), the checking for the guilty identification must be done by a Legal CD with forensic expertise who has an incontestable experience in dental prothesis. The estimated time for the work duration, when evaluated in forensic dentistry examination must be checked based on responsibilities of each one involved in the work: prothesist, patient and laboratory, giving the prothetical rehabilitation the status of field / Mestrado / Odontologia Legal e Deontologia / Mestre em Biologia Buco-Dental
26

Estudo dos parâmetros de estabilidade de travamento entre implante dentário e componente protético através do sistema cone Morse / Study on the stability parameters of locking between dental implants and prosthetic component system through the Morse taper

ARANHA, LUIS C. 28 October 2015 (has links)
Submitted by Claudinei Pracidelli (cpracide@ipen.br) on 2015-10-28T11:29:54Z No. of bitstreams: 0 / Made available in DSpace on 2015-10-28T11:29:54Z (GMT). No. of bitstreams: 0 / Na implantodontia visa-se dois grandes resultados para os desdentados parciais e totais, função mastigatória e estética. Ambos têm o mesmo grau de importância, para tanto se deve pensar no que se tem de mais seguro e prático nos dias de hoje. O cone Morse, na implantodontia oral, é um sistema de estabilidade entre o implante dentário e o parafuso intraósseo de sustentação. Para seu correto uso se faz necessário uma série de análise de suas características e condições. No presente trabalho focou-se em desenvolver protocolo de validação de torque, além de analisar parâmetros de acabamento, deformação e estabilidade précarga e pós-carga dentro de protocolos já recomendados. Avaliou-se sua condição antes e após os efeitos de carga mastigatória simulada por ensaio de fadiga. Concluiu-se que o uso do cone Morse dentro dos protocolos indicados deve ser revisto quanto a padrões similares de torque nos pilares sólidos e indexados, cada um possui limites e indicações diferentes para se manter estável. Concluiu-se também que não é um sistema totalmente livre de trânsito de bactérias e que esse trânsito aumenta de forma proporcional ao uso e força mastigatória, indicando que melhorias no acabamento entre as peças devem ser implementadas e/ou adição de material que afaste crescimento bacteriano priorizando a saúde do periodonto e do tecido ósseo de sustentação mantendo o sistema seguro em longevidade. / Tese (Doutorado em Tecnologia Nuclear) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
27

Modelamento médico: uma integração entre CAD, CAE, engenharia reversa e prototipagem rápida / Medical modeling: an integration among CAD, CAE, reverse engineering and rapid prototyping

Marco Antonio Oliveira Coelho 29 April 2003 (has links)
Modelamento médico é uma técnica utilizada por cirurgiões no auxílio da diagnose, comunicação com o paciente, estudos pré-operatórios, definição e simulação de procedimentos cirúrgicos, visando diminuir o tempo cirúrgico e de convalescença do paciente. Em aplicações mais recentes, esta técnica tem sido utilizada no desenvolvimento de próteses personalizadas, possibilitando que reconstituições de grande complexidade sejam feitas de maneira rápida e segura. Resumidamente, a técnica consiste em produzir um protótipo em terceira dimensão do tecido ou deformidade em estudo. Utiliza-se hoje de modernas tecnologias como tomografia computadorizada e prototipagem rápida entre outras, representando um exemplo significativo de integração entre diferentes áreas do conhecimento. Este trabalho apresenta e discute o modelamento médico no que se refere às suas aplicações, enfocando a integração entre as tecnologias de prototipagem rápida, engenharia reversa (RE) e projeto e engenharia assistidos por computador (CAD/CAE). É feita uma descrição dos procedimentos de geração dos modelos médicos usando técnicas de prototipagem rápida a partir de dados obtidos de tomografia computadorizada, e um estudo de sua precisão dimensional e geométrica. São explorados os recursos possibilitados pela integração com sistemas CAD/CAE, e apresentadas aplicações reais das técnicas na área de cirurgias craniofaciais, evidenciando as vantagens de sua utilização e validando os procedimentos propostos. / Medical modeling is a technique used by surgeons in the diagnosis, communication with the patient, preoperative studies, definition and simulation of surgical procedures. It helps to reduce the operative and convalescence time. It consists of producing a prototype in third dimension of the tissue or deformity in study. In some more recent applications, this technique has been used to develop customized prosthesis, enabling that quite complex reconstructions can be made in a safe and fast way. Nowadays, it uses modern technologies as the computer tomography and rapid prototyping, and it represents significant example of integration among different areas of the knowledge. This work presents the medical modeling and discusses its applications, with emphasis in the integration of the technologies of rapid prototyping, reverse engineering (RE) and computer aided design and engineering (CAD/CAE). It is made a description of the procedures to generate the medical models using rapid prototyping techniques starting from computer tomography data, and a study regarding the dimensional and geometric precision of the medical models generated by rapid prototyping. The advantages of the integration with CAD/CAE technologies are shown and a case study is developed aiming to validate the proposed procedures.
28

Processamento de próteses totais: influência de 4 técnicas na alteração daposição dos dentes artificiais. / The processing of complete denture: influence of four techniques in artificial teeth movement.

William Barnabé 03 April 2000 (has links)
O processamento de resinas acrílicas utilizadas na confecção de bases de prótese envolve alterações dimensionais e distorções da base e movimentação dos dentes artificiais que podem levar à não utilização das próteses por desadaptação, dificuldade de engrenamento dos dentes e estética. Esse estudo avaliou a relação entre a movimentação dos dentes artificiais com os procedimentos de inclusão, prensagem e polimerização das bases de próteses totais. Foram utilizadas 64 amostras, divididas em quatro grupos de 16 (8 inferiores e 8 superiores) que receberam o seguinte tipo de inclusão, prensagem e processamento: a) grupo 1: neste grupo todas as amostras foram incluídas em muflas reforçadas de fibra de vidro, com muralha de silicona, prensagem por uma hora e polimerização em microondas, b) grupo 2: neste grupo todas as amostras foram incluídas em muflos metálicos, com muralha de silicona, prensagem por 12 horas e polimerização em banho de água, utilizando o ciclo de curta duração, c) grupo 3: neste grupo todas as amostras foram incluídas em muflas reforçadas de fibra de vidro, adaptadas para injetora de acrílico, com muralha de gesso pedra e polimerização em microondas, uma hora após a injeção do molde e d) grupo 4: neste grupo todas as amostras foram incluídas em muflos metálicos, com muralha de silicona, prensagem por uma hora e polimerização em banho de água, utilizando o ciclo de curta duração. Com os resultados obtidos podemos concluir que: a) todas as amostras sofreram contração após o processamento, b) a técnica com menor movimentação dos dentes artificiais foi a técnica 1, que apresentou diferença estatisticamente significativa em relação às demais c) quando comparados os arcos superiores e inferiores, independente da técnica e das medidas avaliadas, não se percebeu diferença estatisticamente significativa d) O tempo de prensagem, após a inclusão e antes da polimerização das próteses, interferiu na movimentação dos dentes artificiais e e) a medida que apresentou maior alteração foi a distância entre os molares, com diferença estatisticamente significativa com as demais. / The processing of acrylic resins used in the construction of complete denture bases involve dimensional alterations, distortion and artificial tooth movement which may prevent the prosthesis from being used due to discomfort, inadequate occlusion and esthetics. This study evaluated the relationship between artificial tooth movement, with the procedures of inclusion, compression and polymerization of complete dentures bases. The sixty-four samples utilized were divided into four groups of 16 (8 lower and 8 upper) which received the following type of inclusion, compression and processing: a) group 1: in this group all samples were included in resin-fiber reinforced flasks, with a silicone mould, compression for one hour and microwave polymerization; b) group 2: in this group all samples were included in metallic flasks, with a silicone mould, compression for 12 hours and thermopolymerization in water bath, using a short duration cycle; c) group 3: in this group all samples were included with gypsum stone mould using an acrylic injector to insert the resin inside the flasks, followed by microwave polymerization, one hour after mould injection and; d) group 4: in this group all samples were included in metallic flasks, with a silicone mould, compression for one hour and thermopolymerization in water bath, using short duration cycle. According to the results the following conclusions were drawn: a) contraction was observed in all samples after processing; b) group 1 presented statistically significant less artificial tooth movement, relative to the others; c) comparing the upper and lower arches, regardless of the technique and measurements evaluated, no statistically significant difference was found; d) the compression time following inclusion and before prostheses polymerization had a negative effect on artificial tooth movement and e) the biggest discrepancies were found in the distance between contralateral molars, with statistically significant difference to other measurements.
29

Projeto e construção de parte estrutural de protese de mão humana com movimentos / Design and fabrication of a mobile part of a human hand prothesis

Polis, João Eduardo 14 August 2018 (has links)
Orientador: Cecilia Amelia de Carvalho Zavaglia / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-08-14T13:19:50Z (GMT). No. of bitstreams: 1 Polis_JoaoEduardo_M.pdf: 6036142 bytes, checksum: dadf234cb5c40223223dbe5c453fce7a (MD5) Previous issue date: 2009 / Resumo: Devido ao grande número de pessoas que necessitam do uso de prótese para substituir um membro com seu funcionamento normal afetado, seja por deficiência congênita ou nos casos em que haja necessidade de remoção, ocasionada por doenças ou lesões com trauma, como acidentes do trabalho e de trânsito, foi desenvolvido neste trabalho o projeto e construção da parte estrutural de uma prótese de mão humana, com dimensões e movimentos mecânicos em similaridade (física) com o membro original. Em analogia com uma máquina, a mão é uma ferramenta terminal com atuadores exercendo várias funções como preensão de objetos, movimentação, sensibilidade à textura e temperatura. Entre os membros superiores, é o mais utilizado, exposto e complexo, que quando demanda sua substituição por uma prótese encontra obstáculos em várias áreas, desde aspectos tecnológicos, morfológicos, psicológicos e ainda financeiros. O mercado mundial de próteses dispõe de modelos com tecnologia avançada, que oferecem grande gama de recursos, mas por se tratar de um produto que ainda não é produzido em larga escala, que possui componentes de alta tecnologia e alto custo, não atinge o grande número de pessoas que necessitam da sua utilização. A pesquisa desenvolvida neste trabalho adotou uma metodologia de projeto que buscou a facilidade de construção e a utilização de componentes e matérias-primas disponíveis no mercado e de custo relativamente baixo, podendo assim desenvolver a base estrutural de um produto em desenvolvimento, que incorporará em suas etapas futuras as áreas de motorização, sensorização e revestimento cosmético, visando a obtenção de uma prótese de mão humana que realize movimentos atendendo a impulsos mioelétricos gerados pelo paciente, e que seu custo final de construção, variedade de movimentos e praticidade na colocação viabilizem sua utilização por um maior número de pessoas. / Abstract: The number of handicapped people in need of a particular kind of prosthesis is a compelling reason for carrying out this study, for developing a design and fabrication of a human forelimb prosthesis with dimensions and mechanical movements in similarity (physical) with a human hand. Some of theses handicaps may be a result of accidents, congenital diseases, injuries, or even amputations. Analogous to a machine, a hand is a sensitive terminal tool that is able to grip, move, feel and measure temperatures of objects. It is a very useful and complex member of the human body, and when is necessary to replace it with a prosthesis, there are technological, morphological, psychological and also financial barriers. The world market of prosthesis offers high technology models and a very wide range of resources. However, these products are made of expensive hi-tech components. Moreover, most people cannot afford to buy these expensive products because there is still no large-scale production. Thus, this research project aims at building a prosthetic forelimb with dimensions and mechanical movements similar to those of the human hand, using relatively low cost components and raw materials for manufacturing the final product. This new prosthesis has sensitized "nerve" endings, cosmetic coating, and it is also motorized. It responds to myoelectric impulses generated by the patient. In addition, it is cheap, practical, and it has a variety of movements witch allow it to be used by a large number of people. / Mestrado / Materiais e Processos de Fabricação / Mestre em Engenharia Mecânica
30

Estabilidade do parafuso do intermediário em implantes de conexão externa e interna, após ensaio de fadiga

Paulo César Pinheiro Feitosa 22 August 2007 (has links)
A reabilitação de pacientes desdentados totais e parciais com próteses implantossuportadas constitui, atualmente, um dos tratamentos de eleição na Odontologia. O sucesso do tratamento está relacionado com a precisão e adaptação dos componentes, assim como com a estabilidade da interface implante/intermediário quando submetida a cargas durante a mastigação. A restauração unitária é biomecanicamente mais complexa, principalmente em se tratando de unidades posteriores. O objetivo deste trabalho foi comparar o valor de torque e de destorque do parafuso de intermediários de hexágono externo, hexágono interno e cone morse em restaurações unitárias, antes e após ensaio mecânico. Quinze corpos de prova foram divididos em três grupos: Grupo A implante de hexágono externo, Grupo B implante de hexágono interno e Grupo C implante cone morse. Sobre os implantes foram parafusados munhões universais e sobre estes cimentadas coroas metálicas. As amostras foram submetidas a ensaio mecânico de um milhão de ciclos, com freqüência de 8 ciclos por segundo e sob carga de 400 N. Aplicação e registro dos valores de torque e destorque dos parafusos do intermediário foram realizados antes e depois do ensaio. Por meio do teste de Tukey, adotando-se nível de significância de 5%, não foi observada diferença estatisticamente significativa entre os valores de destorque inicial e final das amostras dentro de um mesmo grupo. Porém, foi evidenciada diferença estatisticamente significativa dos valores iniciais entre os grupos A e C e dos valores finais entre os grupos A e B, A e C, B e C. A conexão cone morse apresentou os maiores valores de destorque inicial e final, mostrando-se mais estável. / Currently the rehabilitation of patients totally or partially toothless with implantsupported prothesis constitutes a primary choice treatment in Dentistry. The success of the treatment is related to the precision and adaptation of components, as well as to the stability of the implant/abutment interface submitted to mastication loads. The unitary restoration is bio-mechanically more complex, especially for the posterior units. The objective of this study is to compare values of torque and detorque recorded for the screw of the abutment with external hexagon, internal hexagon and morse taper in unitary restorations, before and after the mechanical test. Fifteen samples were divided into three groups: Group A implant of external hexagon; Group B implant of internal hexagon and Group C morse taper implant. Universal abutments were torqued over the implants and metallic crowns were cemented over the abutments. Samples were submitted to mechanical test of a million cycles, frequency of 8 cycles per second and load equivalent to 400 N. Application and recording of torque and detorque values at screws of the abutment were carried out before and after the mechanical test. Results of a Tukey test with a 5% level of significance showed no statistically significant difference between the initial and the final detorque values in samples of the same group. However, a statistically significant difference was found for the initial detorque values between the groups A and C and for the final detorque values between A and B, A and C, B and C. The Morse taper connection showed higher values of initial and final detorque values, therefore bearing increased stability.

Page generated in 0.0614 seconds