• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 54
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 57
  • 57
  • 48
  • 48
  • 45
  • 34
  • 34
  • 31
  • 27
  • 23
  • 21
  • 20
  • 17
  • 15
  • 14
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Pressur : o resgate da pesquisa em co-gestão sindical sobre pressão arterial elevada, surdez ocupacional e fatores de risco

Costa, Luciana Scarlazzari 03 August 2018 (has links)
Orientador : Heleno Rodrigues Correa Filho / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciências Médicas / Made available in DSpace on 2018-08-03T00:15:23Z (GMT). No. of bitstreams: 1 Costa_LucianaScarlazzari_M.pdf: 864065 bytes, checksum: 4e6683a75e6c511a16ff73347174d842 (MD5) Previous issue date: 2002 / Resumo: Apresenta-se um estudo epidemiológico transversal, com amostra aleatória probabilística da categoria de motoristas de ônibus de Campinas, que tem por objetivos: 1) Estimar a prevalência de Perda Auditiva Induzida por Ruído (PAIR); 2) Verificar a associação entre os casos diagnosticados de PAIR e os de hipertensão arterial sistêmica (HAS); e também as possíveis associações de PAIR com variáveis: demográficas, sócio-econômicas, hábito de fumar, ocupacionais e de morbidade. Foram estudados 108 motoristas de ônibus no ano de 1991. Aplicou-se questionário para obter história profissional detalhada e realizaram-se exames clínicos para medir a pressão arterial e exames audiométricos para, segundo a classificação de Merluzzi, obter o diagnóstico de PAIR. As possíveis associações entre os casos de PAIR e variáveis já referidas foram verificadas utilizando-se o teste de associação pelo 2. Realizaram-se as análises univariada e múltipla através do modelo de Regressão Logística. A prevalência encontrada para a PAIR foi de 32,7% do total de examinados (104) com IC95% [23,7; 41,7]. As variáveis que encontraram-se associadas com a PAIR, na análise univariada, foram: Idade (p=0,005); Tempo como motorista urbano (p=0,03); Relato de exposição a produtos químicos com metais (p=0,03) e Relato de zumbido (p=0,04). Após análise múltipla, identificaram-se dois possíveis modelos: 1) com Tempo urbano e exposição a metais e 2) com Idade e exposição a metais. Optou-se pelo modelo que leva em consideração o tempo trabalhado como motorista de ônibus urbano, tendo-se em vista que este é o único marcador da exposição profissional ao ruído com plausibilidade biológica específica para a PAIR. Há evidências de que o tempo de trabalho como motorista de ônibus urbano e a exposição a produtos químicos com metais estão associados à prevalência de PAIR entre os motoristas, porém este último é um resultado que deve ser visto com cautela uma vez que o desenho do estudo não permite, com base somente nestes resultados, interpretar esta associação como sendo de natureza causal / Abstract: A cross sectional epidemiological study with probabilistic random sample of Campinas bus drivers is presented with the following objectives: 1) to estimate prevalence of noise induced hearing loss (NIHL); 2) to verify the association between the cases of NIHL and hypertension; and also the possible association of NIHL with demographics, social-economics, smoking habits, occupational and morbid variables. In 1991 a sample of 108 bus drivers was studied. A questionnaire was used to get a detailed professional history, clinical and audiometric exams that were done to measure the arterial blood pressure and to get, in accordance with Merluzzi classification, NIHL diagnosis. The possible associations between the cases of NIHL and variables described above were verified using ?2 association test. Univariate and multivariate analysis were done using logistic regression model. The prevalence for NIHL was 32,7% of the total examined people (104) with CI95%[23,7; 41,7]. The variables that were associated with NIHL in univariate analysis were: age (p=0,005); time worked as urban bus driver (p=0,03); relate of exposure to chemical products with metals (p=0,03) and the history of tinitus (p=0,04). After multivariate analysis, two possible models were identified: 1) with urban time and metals exposure and 2) with age and metals exposure. The chosen model was the one that considers the time worked as urban bus drivers because it's the unique noise professional exposure marker with biologic plausibility for NIHL. There are evidences that the time worked as urban bus driver and the exposure to chemical products with metals are associated with the prevalence of bus driver¿s NIHL, but this result should be seen cautiously once the study design does not allows for interpreting this association as being of causal nature / Mestrado / Mestre em Saude Coletiva
2

Desenvolvimento de teste de reconhecimento de fala, com ruido, em portugues do Brasil, para aplicação em audiologia ocupacional

Costa, Everardo Andrade da 12 September 1998 (has links)
Orientador: Ericson Bagatin / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-07-25T15:17:59Z (GMT). No. of bitstreams: 1 Costa_EverardoAndradeda_D.pdf: 3631259 bytes, checksum: 889a8f26f5d268bd6fa2fbd5c9059964 (MD5) Previous issue date: 1998 / Resumo: Desenvolveu-se um teste de reconhecimento de fala, com ruído, para ser aplicado na avaliação das desabilidades de trabalhadores portadores de perdas auditivas induzidas pelo ruído (P AIR). Utilizaram-se nove listas de 25 vocábulos, na maioria monossilábicos, em português do Brasil, gravadas em disco compacto, com voz masculina, para apresentação monoaural, com fones, por via de audiômetro. Utilizou-se, também, um ruído competidor, com espectro de fala e modulações de amplitude, gravado no segundo canal do disco compacto. O material e o método foram padronizados com 30 voluntários otologicamente normais, com determinação da variância e elaboração de curvas de reconhecimento de fala. Nas apresentações dos sinais de fala sem ruído competidor, com 21 sujeitos, os 50% de reconhecimento foram alcançados em 19,1 dB NS, com contagem de palavras identificadas e em 15,1 dB NS, com contagem de fonemas. A inclinação das curvas, em torno de 50% de reconhecimento, foi de 3,4 %/dB, com contagem de palavras e 4,0 %/dB, com contagem de fonemas. Nas apresentações dos sinais de fala com ruído, com 30 sujeitos, os 50% de reconhecimento foram alcançados na relação sinal/ruído -10,5 dB, com contagem de palavras e -13,8 dB, com contagem de fonemas. A inclinação das curvas, em torno de 500/Ó de reconhecimento, foi de 5,0 %/dB, com contagem de palavras e 6,3 %/dB, com contagem de fonemas. A equivalência entre as nove listas foi determinada, inicialmente, por equilíbrio fonêmico. Nos testes com os sujeitos normo-ouvintes, a equivalência só foi verificada entre oito das nove listas, pela contagem de fonemas, com e sem ruído competidor, em níveis confortáveis de apresentação. Nas apresentações em níveis justaliminares, a equivalência só foi verificada entre quatro listas, nas apresentações sem ruído, e entre seis listas, nas apresentações com ruído. Os vocábulos com as vogais anteriores e centrais (/e/,/e/,/i/,/aJ), com as consoantes fricativas (/fJ,Iv/,/s/,IzJ'/SI'/3f) e com as consoantes oclusivas /tI e Id/ obtiveram, em média, melhores percentuais de reconhecimento do que as demais. Concluiu-se que o teste de reconhecimento de fala, com ruído, pode ser aplicado na rotina de clínicas dedicadas à audiologia ocupacional. Serão necessários, contudo, novos estudos, com trabalhadores expostos a níveis elevados de pressão sonora, para se estabelecer os respectivos dados normativos / Abstract: A test material was developed consisting of nine monosyllabic 25-word lists in Brazilian Portuguese and a speech weighted modulated noise, recorded on compact disk. This material was tested on normal hearing people and normative data and speech recognition curves were obtained, in quiet and in noisy conditions, with word scores and phoneme scores. This speech test is intended to be adequate for handicap assessment of noise exposed workers. With 21 normal hearing non-experienced subjects and the speech test in quiet condition, the mean 50% recognition was obtained at the leveI 19.1 dB SL, on word scores and 15.1 dE SL, on phoneme scores; the recognition curves had a slope of 3.4 %/dB on word scores and 4.0 %/dB on phoneme scores. With 30 normal hearing subjects and the speech test in noisy condition, the mean 50% recognition was obtained at the signallnoise ratio -10.5 dE on word scores, and 13.8 dB, on phoneme scores; the recognition curves have got a slope of 5.0 %/dB on word scores and 6.3 %/dB on phoneme scores. The equivalence of the 9 monosyllabic lists, determined first, by their phonetic features,. was verified in tests in 8 lists, at a comfortable presentation leveI, both in quiet and in noise. When presented close to 50% recognition leveI, the equivalence was verified only in 4 lists in quiet and 6 lists in noise. Words with anterior or central vowels and with rncatives and stop IdI and ItI consonants had better recognition scores then those without them. Speech recognition scores in noise with monosyllabic 25-word lists are recommended for everyday clinical use. Further studies are necessary for setting normative data on hearing impaired workers / Doutorado / Saude Coletiva / Doutor em Ciências Médicas
3

Prevalencia de queixas de disfunções auditivas e vestibulares em trabalhadores expostos a ruido ocupacional atendidos no centro de referencia de saude do trabalhador de Campinas, no periodo de 1997 a 2003

Ogido, Rosalina 27 February 2004 (has links)
Orientador: Everardo Andrade da Costa / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-08-04T02:20:32Z (GMT). No. of bitstreams: 1 Ogido_Rosalina_M.pdf: 7089279 bytes, checksum: 10c9c3ce4222a8f1f570a917ceaf8f8c (MD5) Previous issue date: 2004 / Resumo: A Perda Auditiva Induzida por Ruído Ocupacional (PAIRO) é a segunda causa de doença de origem ocupacional, nos trabalhadores atendidos pelo Centro de Referência de Saúde do Trabalhador (CRST) de Campinas. Foi realizado um estudo retrospectivo, dos trabalhadores com diagnóstico de PAIRO atendidos no CRST no período de 1997 a agosto de 2003. o objetivo foi avaliar a freqüência dos sintomas de disfunções auditivas e vestibulares como hipoacusia, zumbido e vertigem nestes trabalhadores, descrever a casuística e comparar os tipos de sintomas relatados com as variáveis idade, tempo de exposição ao ruído e limiares auditivos tonais. Foram pesquisados os prontuários médicos de 175 trabalhadores submetidos a avaliação audiológica e ocupacional, do banco de dados do CRST. Para descrever o perfil da amostra segundo as diversas variáveis em estudo, foram feitas tabelas de freqüência das variáveis categóricas e estatísticas descritivas das variáveis contínuas. Para analisar a associação entre os tipos de queixas e as variáveis categóricas de interesse foram utilizados o teste Qui-Quadrado ou o teste exato de Fisher. A amostra foi constituída de 174 homens e 1 mulher, com idade de 21 a 63 anos, média de tempo total de exposição ao ruído de 15,75anos. o principal ramo de atividade foi o da indústria metalúrgica, com 71,26% da amostra. Os sintomas vestibulares (tontura, vertigem), foram relatado em 13,22% dos casos, dos quais 88, 24% com freqüência esporádica. Em 80,81% dos relatos, houve a presença de zumbido. Destes, 54,14% de forma constante. Tanto os sintomas vestibulares quanto o zumbido não tiveram correlação com os limiares auditivos nem com o tempo de serviço. O sintoma hipoacusia foi relatado em 74,12% dos casos e apresentou correlação tanto com o tempo de serviço quanto com a idade e os limiares auditivos. Conclusões: Apesar dos avanços no conhecimento e na legislação sobre PAIR, ainda existem trabalhadores lesionados pelo ruído. Esta doença ocupacional gera inúmeros prejuízos para a sociedade e para o indivíduo acometido, seja dificultando a sua inserção no mercado de trabalho, seja prejudicando sua capacidade de comunicação e qualidade de vida, como demonstrado pela ocorrência de disfunções auditivas. Enfatiza-se a necessidade de prevenção da exposição ao ruído no ambiente de trabalho e fora dele, nos programas de educação, no diagnóstico precoce e no aprimoramento dos métodos de avaliação audiológica para as disfunções auditivas / Abstract: Noise Induced Hearing Loss is the second cause of occupational disease in the workers avaliated at Campinas Centro de Referência de Saúde do Trabalhador (CRST) . A retrospective study was conducted, avaliating the workers with the diagnosis of noise induced hearing loss attended at CRST from1997 to August 2003. The objective was to study the ITequencyof auditive disfunctions symptoms as difficulty to hear, tinnitus and vertigo in these workers, to describe the casuistic and to compare the related symptoms with the variables: duration of exposure to occupational noise, age and auditive thresholds. After audiological and occupational evaluation, the data of 175 workers with noise induced, loss diagnosis were stored at the CRST data bank Epi Info Program, version 6. To describe the sample profile according to the different variables studied, frequency tables of the categoric variables and descriptive statistic from the continuous variables were employed. To analyse the association between the complaints and the categoric variables of interest, the Qui-Square test or the Fisher exact test were employed. The gender distribution was 174 men and 1 woman, age from21 to 63 years old and the mean of occupational noise exposition time was 15.75years. The main function was metallurgical with 71.26% ofthe population. The dizziness symptom was related in 13.22% of the cases, 88,24% sporadically. The tinnitus was referred in 80.81% ofthe cases. In 54.14% the symptom was constant. To the dizziness and tinnitus, there was no correlation between the symptom with the auditory thresholds, nor the occupation noise exposure time. The hearing loss complaint was referred in 74.12% of the cases, and presents correlation with both the occupation noise exposure time, the age and the auditory thresholds, in the mean thresholds of 500, 1000 and 2000 Hz and 3000, 4000 and 6000 Hz, bilaterally. Conclusions: Despite of advances in the knowledge and in the legislation about noise induced hearing loss, there are still many workers impaired by noise exposure.This occupational disease causes losses to the society and to the injured worker: difficulty in the insertion at a newjob, difficulty in the communication ability and a worse quality of life as demonstrated by the occurrence of the auditive disfunctions. It needs to emphasize the noise exposure prevention at the work environnent and outside it, in the information, instruction and training programes, in the early diagnosis and in extending the audiologic evaluation methods for these disfunctions / Mestrado / Saude Coletiva / Mestre em Saude Coletiva
4

Avaliação de um pograma de preservação auditiva junto a um batalhão do Corpo de Bombeiros /

Silva, Giovanna Cesar. January 2016 (has links)
Orientadora: Ana Cláudia Vieira Cardoso / Co-orientadora: Cláudia Giglio de Oliveira Gonçalves / Banca: Ana Cláudia Figueiredo Frizzo / Banca: Helenice Yemi Nakamura / Resumo: A exposição cotidiana ao ruído pode causar alterações auditivas. Os bombeiros são uma população de risco para essas alterações pois em seu cotidiano estão expostos a níveis elevados de pressão sonora. Implantar um Programa de Preservação Auditiva para esses profissionais é fundamental para promover sua saúde auditiva. Desta forma, o objetivo deste estudo foi avaliar o nível de conhecimento e atitudes de bombeiros em relação a audição e a eficácia de um programa de preservação auditiva para esses profissionais. Este foi um estudo prospectivo, comparativo, de coorte contemporânea com corte transversal. O mesmo foi realizado junto a prontidão do 10º grupamento do Corpo de Bombeiros. Compuseram... / Abstract: Daily exposure to noise can cause hearing loss. Firefighters are a population at risk for these pathology, because in their daily lives, are exposed to high sound pressure levels. So implement a Hearing Conservation Program for these professionals is essential to promote their hearing health. Thus, the aim of this study was to evaluate the level of knowledge and attitudes of firefighters about hearing and the effectiveness of a hearing conservation program for these professionals. This was a prospective, comparative, cross-sectional cohort study. It was developed with professionals of readiness of the 10th Fire Department Company. The sample consisted of 20 firefighters who responded to a... / Mestre
5

Avaliação audiológica e quantificação da exposição ao ruído em profissionais do corpo de bombeiros /

Taxini, Carla Linhares. January 2013 (has links)
Orientador: Heraldo Lorena Guida / Banca: Claudia Giglio de Oliveira Gonçalves / Banca: Ana Claudia Vieira Cardoso / Resumo: O bombeiro é um profissional que possui treino e equipamento adequado para desenvolver diversas tarefas como apagar incêndios, resgatar pessoas e fornecer assistência em desastres naturais, e dessa forma, estão constantemente expostos ao ruído. Tal exposição pode ocasionar a perda auditiva induzida pelo ruído (PAIR), que se caracteriza por uma perda insidiosa e cumulativa, do tipo neurossensorial. Sendo assim objetivou-se delinear o perfil audiológico dos bombeiros e mapear os diferentes ambientes acústicos a que estes profissionais se expõem. Participaram desse estudo 41 bombeiros que foram submetidos à anamnese audiológica, inspeção do conduto auditivo, audiometria tonal liminar, logoaudiometria, imitanciometria e emissões otoacústica evocadas por produto de distorção (EOAPD). Foram realizadas também as medições das exposições dos níveis de pressão sonora (NPS) dos equipamentos e nos ambientes do 10º Grupamento de Bombeiros da cidade de Marília-SP utilizando um audiodosímetro digital. Como resultado obteve-se 11 (27%) dos bombeiros com limiares tonais sugestivos de PAIR, no entanto, destes, apenas 4 (36%) foram bilaterais, 2 (18%) unilaterais com orelha contralateral não sugestiva de PAIR e 5 (46%) unilaterais com orelha contralateral normal. Nas amplitudes das EOAPD houve diferença significativa entre as orelhas normais e as orelhas sugestivas de PAIR nas frequências de 4 e 6 kHz à direita e 6 kHz à esquerda, e entre as orelhas normais e não sugestivas de PAIR em 2, 3 e 6 kHz à direita e em 1, 2, 3, 4, 6 e 8 kHz à esquerda. Houve correlação significativa entre os resultados das audiometrias tonais liminares e as EOAPD para as frequências de 2, 3, 4 e 6 kHz à direita e para 1, 2, 3, 4, 6, e 8 kHz à esquerda. No mapeamento sonoro as medições realizadas na Central de Operações dos Bombeiros Militares (COBOM) registraram nível equivalente... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The firefighter is a professional who has training and equipment to conduct various tasks such as putting out fires, rescue people and give assistance in the natural disaster, so they are constantly exposed to the noise. This exposure can lead to noise-induced hearing loss (NIHL), which is characterized by an insidious and cumulative sensorineural loss. The aim was trace the audiological profile of firefighters and to analyze the acoustic environments that these professionals are exposed. The study included 41 firefighters who were submitted to audiologic anamnesis, inspection of the external auditory canal, pure tone audiometry, speech audiometry, tympanometry and distortion product otoacoustic emissions (DPOAE). Were also carried out measurements the sound pressure levels of the equipment and environments in the 10th Fire Department in Marília-SP using a digital dosimeter. The result of this study showed 11 (27%) of firefighters had hearing thresholds suggestive of NIHL, however only 4 (36%) of these cases were suggestive of bilateral NIHL, 2 (18%) was unilateral with opposite ear not suggestive of NIHL, and 5 (46%) was unilateral with opposite normal ear. It was observed statistical difference in DPOAE the amplitudes of normal ears and of ears suggestive of NIHL in the frequencies of 4 and 6 kHz at the right ear and 6 kHz at the left ear, and between normal ears and the ears not suggestive of NIHL in 2, 3 and 6 kHz at the right and 1, 2, 3, 4, 6 and 8 kHz at the left ears. There was correlation between the results of pure tone audiometry and DPOAE in 2, 3, 4 and 6 kHz frequencies of right ears and 1, 2, 3, 4, 6, and 8 kHz of left ear. In the sound mapping, the measurements performed in the Operations Center of Military Firefighters recorded the equivalent noise level (Leq) was 79,35 dB(A) in the external environment and 92,37 dB(A) in the head-sets... (Complete abstract click electronic access below) / Mestre
6

Estudo de associação do genoma inteiro para descoberta de genes da susceptibilidade à perda auditiva induzida por ruído

Lavinsky, Joel January 2015 (has links)
Nos Estados Unidos, aproximadamente 10% da população é exposta diariamente a níveis perigosos de ruído no ambiente de trabalho. Estudos com gêmeos estimam que a herdabilidade para a perda auditiva induzida por ruído (PAIR) é de aproximadamente 36%, e tem sido demonstrada variação da sensibilidade ao ruído em linhagens específicas de camundongos. Devido à dificuldade inerente do estudo da PAIR em humanos, optou-se por estudar esse traço complexo em camundongos. Camundongos do Hybrid Mouse Diversity Panel (HMDP) com 5 semanas de idade foram expostos a um ruído de banda na oitava de 10 kHz por 2 horas a 108 dB. A mudança permanente no limiar foi avaliada após 2 semanas da exposição ao ruído, através de estímulos com frequência-específica. Esses dados foram então aplicados em um estudo de associação do genoma inteiro através do Efficient Mixed Model Analysis (EMMA) a fim de controlar para estrutura populacional. Neste manuscrito será descrito o estudo de associação do genoma inteiro com ênfase num pico de associação significativo para susceptibilidade à PAIR. Esse pico está no cromossomo 17 e em um bloco de haplótipo contendo a NADPH oxidase-3 (Nox3). Esse pico foi detectado em um fenótipo com estímulo de 8 kHz (tone-burst). Os mutantes homozigotos e os heterozigotos Nox3 foram então testados para validar o achado identificado no estudo de associação do genoma inteiro. Os mutantes e heterozigotos demonstraram uma maior susceptibilidade à PAIR, especialmente em 8 kHz, tanto através das medidas de emissões otoacústicas por produto de distorção (EOAPD) quanto por potenciais evocados auditivos de tronco cerebral (PEATE). Foi demonstrado por imuno-histoquímica que essa sensibilidade reside nas bandas sinápticas cocleares dos animais mutantes, especialmente em 8 kHz. Os mutantes homozigotos e os heterozigotos Nox3 foram então testados para validar o achado identificado no estudo de associação do genoma inteiro. Os mutantes e heterozigotos demonstraram uma maior susceptibilidade à PAIR, especialmente em 8 kHz, tanto através das medidas de emissões otoacústicas por produto de distorção (EOAPD) quanto por potenciais evocados auditivos de tronco cerebral (PEATE). Foi demonstrado por imuno-histoquímica que essa sensibilidade reside nas bandas sinápticas cocleares dos animais mutantes, especialmente em 8 kHz. Este é o primeiro estudo de associação do genoma inteiro para PAIR em camundongos e demonstra o poder dessa estratégia em identificar, de forma tonotópica, a susceptibilidade genética à PAIR.
7

Avaliação da perda auditiva ocupacional associada à exposição simultânea a ruído e cromo / Evaluation of occupational hearing loss associated with simultaneous exposure to noise and chromium

Bitu, Carlene de Souza January 2011 (has links)
BITU, Carlene de Souza. Avaliação da perda auditiva ocupacional associada à exposição simultânea a ruído e cromo. 2011. 131 f. Dissertação (Mestrado em Farmacologia) - Universidade Federal do Ceará. Faculdade de Medicina, Fortaleza, 2011. / Submitted by denise santos (denise.santos@ufc.br) on 2013-07-15T11:46:03Z No. of bitstreams: 1 2011_dis_csbitu.pdf: 1563744 bytes, checksum: f8524447b0c00495710f2c843b7a89ee (MD5) / Approved for entry into archive by Erika Fernandes(erikaleitefernandes@gmail.com) on 2013-07-16T14:17:15Z (GMT) No. of bitstreams: 1 2011_dis_csbitu.pdf: 1563744 bytes, checksum: f8524447b0c00495710f2c843b7a89ee (MD5) / Made available in DSpace on 2013-07-16T14:17:15Z (GMT). No. of bitstreams: 1 2011_dis_csbitu.pdf: 1563744 bytes, checksum: f8524447b0c00495710f2c843b7a89ee (MD5) Previous issue date: 2011 / A saúde do trabalhador no Brasil tomou novo rumo com uma nova visão, mais ampla e integral do processo saúde-doença, considerando-se as questões relacionadas a acidentes e doenças ocupacionais sobre o trabalho. Dentre as várias doenças estão a Perda Auditiva Induzida pelo Ruído (PAIR) e os trabalhadores que são continuamente expostos a compostos químicos em ambientes industriais. Entre estes, figuram os chamados compostos hexavalentes e os compostos formados por cromo trivalente. O objetivo desta pesquisa foi verificar se a exposição simultânea de ruído e cromo potencializa o aparecimento da perda auditiva ocupacional dos trabalhadores de curtume em Teresina-PI. As características da população em estudo, são todos os trabalhadores do sexo masculino, divididos em 3 grupos, sendo: Grupo I - exposto a cromo e ruído (n = 9); Grupo II - exposto a ruído (n = 9); Grupo III - controle (n =10) na faixa etária de 38,11 ± 5,9 , 30,83 ± 7,4 e 27,40 ± 7,0 anos, respectivamente. Os trabalhadores do Grupo I e II trabalham em média 9 horas diárias e 22,2% do grupo I apresentam problemas cardiovasculares e 16,7% do grupo II alteração da pressão arterial. Em relação ao tempo de trabalho, verifica-se um maior tempo de trabalho para os trabalhadores expostos a cromo e ruído em média 13 anos, estes desenvolvem suas atividades laborais em sua maioria nos setores de curtimento, classificação de peles e Ribeira, são os que estão em contato permanente com o cromo (55%), enquanto que os expostos a ruído (grupo II) são os trabalhadores dos setores de acabamento, rebaixamento e lixadeira de couro (83,3%). Quando relacionado à função e de acordo com a categoria profissional os que mais se expõem a ruído e cromo são os auxiliares de produção, (44,5% exposto a ruído e cromo e 91,5% expostos a ruído). Em relação aos EPIs somente (55,6%) de trabalhadores expostos ao cromo e ruído utilizam protetor auricular do tipo plug; e nenhuma proteção para o cromo. Nos expostos somente a ruído o uso de EPI é de apenas 25%. Sobre sua percepção quanto a sua própria audição, todos os grupos referem-na como boa, apenas 20% dos que responderam do grupo I referiu-se a sua audição como ruim. No grupo exposto somente a ruído 8,3% relatam otalgia, enquanto que 100% dos expostos a cromo e ruído fazem esse relato, apresentando significância p< 0,05. Os trabalhadores do Grupo I e II queixam-se de tonturas frequentes (44% e 25%), zumbido (22,2% e 50%) respectivamente. Quanto ao resultado do exame audiométrico, 100% do Grupo Controle e os expostos a Ruído apresentaram Limiares Auditivos dentro dos Padrões de Normalidade enquanto 22,2% dos expostos a cromo e ruído apresentaram perda auditiva neurossensorial. Quando avaliados os parâmetros de cromo na urina, ocorreu um aumento significante no valor da dosagem de cromo dos trabalhadores expostos a cromo e ruído p<0,001 (2,76 ± 0,76 ) em relação aos expostos somente a ruído p<0,05 (1,62 ± 1,77), quando comparados com o controle. Assim salienta-se a necessidade de investigação da perda auditiva em trabalhadores de curtume como estratégia de prevenção, associados a contínuos programas educacionais relacionados ao uso correto de equipamentos de proteção individual tanto na exposição a substâncias químicas como para ruído.
8

Avaliação audiológica e quantificação da exposição ao ruído em profissionais do corpo de bombeiros

Taxini, Carla Linhares [UNESP] January 2013 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:15Z (GMT). No. of bitstreams: 0 Previous issue date: 2013Bitstream added on 2014-06-13T18:51:59Z : No. of bitstreams: 1 taxini_cl_me_mar.pdf: 994922 bytes, checksum: e166b3ee238a723adbb2ea5aaf4a6767 (MD5) / O bombeiro é um profissional que possui treino e equipamento adequado para desenvolver diversas tarefas como apagar incêndios, resgatar pessoas e fornecer assistência em desastres naturais, e dessa forma, estão constantemente expostos ao ruído. Tal exposição pode ocasionar a perda auditiva induzida pelo ruído (PAIR), que se caracteriza por uma perda insidiosa e cumulativa, do tipo neurossensorial. Sendo assim objetivou-se delinear o perfil audiológico dos bombeiros e mapear os diferentes ambientes acústicos a que estes profissionais se expõem. Participaram desse estudo 41 bombeiros que foram submetidos à anamnese audiológica, inspeção do conduto auditivo, audiometria tonal liminar, logoaudiometria, imitanciometria e emissões otoacústica evocadas por produto de distorção (EOAPD). Foram realizadas também as medições das exposições dos níveis de pressão sonora (NPS) dos equipamentos e nos ambientes do 10º Grupamento de Bombeiros da cidade de Marília-SP utilizando um audiodosímetro digital. Como resultado obteve-se 11 (27%) dos bombeiros com limiares tonais sugestivos de PAIR, no entanto, destes, apenas 4 (36%) foram bilaterais, 2 (18%) unilaterais com orelha contralateral não sugestiva de PAIR e 5 (46%) unilaterais com orelha contralateral normal. Nas amplitudes das EOAPD houve diferença significativa entre as orelhas normais e as orelhas sugestivas de PAIR nas frequências de 4 e 6 kHz à direita e 6 kHz à esquerda, e entre as orelhas normais e não sugestivas de PAIR em 2, 3 e 6 kHz à direita e em 1, 2, 3, 4, 6 e 8 kHz à esquerda. Houve correlação significativa entre os resultados das audiometrias tonais liminares e as EOAPD para as frequências de 2, 3, 4 e 6 kHz à direita e para 1, 2, 3, 4, 6, e 8 kHz à esquerda. No mapeamento sonoro as medições realizadas na Central de Operações dos Bombeiros Militares (COBOM) registraram nível equivalente... / The firefighter is a professional who has training and equipment to conduct various tasks such as putting out fires, rescue people and give assistance in the natural disaster, so they are constantly exposed to the noise. This exposure can lead to noise-induced hearing loss (NIHL), which is characterized by an insidious and cumulative sensorineural loss. The aim was trace the audiological profile of firefighters and to analyze the acoustic environments that these professionals are exposed. The study included 41 firefighters who were submitted to audiologic anamnesis, inspection of the external auditory canal, pure tone audiometry, speech audiometry, tympanometry and distortion product otoacoustic emissions (DPOAE). Were also carried out measurements the sound pressure levels of the equipment and environments in the 10th Fire Department in Marília-SP using a digital dosimeter. The result of this study showed 11 (27%) of firefighters had hearing thresholds suggestive of NIHL, however only 4 (36%) of these cases were suggestive of bilateral NIHL, 2 (18%) was unilateral with opposite ear not suggestive of NIHL, and 5 (46%) was unilateral with opposite normal ear. It was observed statistical difference in DPOAE the amplitudes of normal ears and of ears suggestive of NIHL in the frequencies of 4 and 6 kHz at the right ear and 6 kHz at the left ear, and between normal ears and the ears not suggestive of NIHL in 2, 3 and 6 kHz at the right and 1, 2, 3, 4, 6 and 8 kHz at the left ears. There was correlation between the results of pure tone audiometry and DPOAE in 2, 3, 4 and 6 kHz frequencies of right ears and 1, 2, 3, 4, 6, and 8 kHz of left ear. In the sound mapping, the measurements performed in the Operations Center of Military Firefighters recorded the equivalent noise level (Leq) was 79,35 dB(A) in the external environment and 92,37 dB(A) in the head-sets... (Complete abstract click electronic access below)
9

Estudo de associação do genoma inteiro para descoberta de genes da susceptibilidade à perda auditiva induzida por ruído

Lavinsky, Joel January 2015 (has links)
Nos Estados Unidos, aproximadamente 10% da população é exposta diariamente a níveis perigosos de ruído no ambiente de trabalho. Estudos com gêmeos estimam que a herdabilidade para a perda auditiva induzida por ruído (PAIR) é de aproximadamente 36%, e tem sido demonstrada variação da sensibilidade ao ruído em linhagens específicas de camundongos. Devido à dificuldade inerente do estudo da PAIR em humanos, optou-se por estudar esse traço complexo em camundongos. Camundongos do Hybrid Mouse Diversity Panel (HMDP) com 5 semanas de idade foram expostos a um ruído de banda na oitava de 10 kHz por 2 horas a 108 dB. A mudança permanente no limiar foi avaliada após 2 semanas da exposição ao ruído, através de estímulos com frequência-específica. Esses dados foram então aplicados em um estudo de associação do genoma inteiro através do Efficient Mixed Model Analysis (EMMA) a fim de controlar para estrutura populacional. Neste manuscrito será descrito o estudo de associação do genoma inteiro com ênfase num pico de associação significativo para susceptibilidade à PAIR. Esse pico está no cromossomo 17 e em um bloco de haplótipo contendo a NADPH oxidase-3 (Nox3). Esse pico foi detectado em um fenótipo com estímulo de 8 kHz (tone-burst). Os mutantes homozigotos e os heterozigotos Nox3 foram então testados para validar o achado identificado no estudo de associação do genoma inteiro. Os mutantes e heterozigotos demonstraram uma maior susceptibilidade à PAIR, especialmente em 8 kHz, tanto através das medidas de emissões otoacústicas por produto de distorção (EOAPD) quanto por potenciais evocados auditivos de tronco cerebral (PEATE). Foi demonstrado por imuno-histoquímica que essa sensibilidade reside nas bandas sinápticas cocleares dos animais mutantes, especialmente em 8 kHz. Os mutantes homozigotos e os heterozigotos Nox3 foram então testados para validar o achado identificado no estudo de associação do genoma inteiro. Os mutantes e heterozigotos demonstraram uma maior susceptibilidade à PAIR, especialmente em 8 kHz, tanto através das medidas de emissões otoacústicas por produto de distorção (EOAPD) quanto por potenciais evocados auditivos de tronco cerebral (PEATE). Foi demonstrado por imuno-histoquímica que essa sensibilidade reside nas bandas sinápticas cocleares dos animais mutantes, especialmente em 8 kHz. Este é o primeiro estudo de associação do genoma inteiro para PAIR em camundongos e demonstra o poder dessa estratégia em identificar, de forma tonotópica, a susceptibilidade genética à PAIR.
10

Estudo de associação do genoma inteiro para descoberta de genes da susceptibilidade à perda auditiva induzida por ruído

Lavinsky, Joel January 2015 (has links)
Nos Estados Unidos, aproximadamente 10% da população é exposta diariamente a níveis perigosos de ruído no ambiente de trabalho. Estudos com gêmeos estimam que a herdabilidade para a perda auditiva induzida por ruído (PAIR) é de aproximadamente 36%, e tem sido demonstrada variação da sensibilidade ao ruído em linhagens específicas de camundongos. Devido à dificuldade inerente do estudo da PAIR em humanos, optou-se por estudar esse traço complexo em camundongos. Camundongos do Hybrid Mouse Diversity Panel (HMDP) com 5 semanas de idade foram expostos a um ruído de banda na oitava de 10 kHz por 2 horas a 108 dB. A mudança permanente no limiar foi avaliada após 2 semanas da exposição ao ruído, através de estímulos com frequência-específica. Esses dados foram então aplicados em um estudo de associação do genoma inteiro através do Efficient Mixed Model Analysis (EMMA) a fim de controlar para estrutura populacional. Neste manuscrito será descrito o estudo de associação do genoma inteiro com ênfase num pico de associação significativo para susceptibilidade à PAIR. Esse pico está no cromossomo 17 e em um bloco de haplótipo contendo a NADPH oxidase-3 (Nox3). Esse pico foi detectado em um fenótipo com estímulo de 8 kHz (tone-burst). Os mutantes homozigotos e os heterozigotos Nox3 foram então testados para validar o achado identificado no estudo de associação do genoma inteiro. Os mutantes e heterozigotos demonstraram uma maior susceptibilidade à PAIR, especialmente em 8 kHz, tanto através das medidas de emissões otoacústicas por produto de distorção (EOAPD) quanto por potenciais evocados auditivos de tronco cerebral (PEATE). Foi demonstrado por imuno-histoquímica que essa sensibilidade reside nas bandas sinápticas cocleares dos animais mutantes, especialmente em 8 kHz. Os mutantes homozigotos e os heterozigotos Nox3 foram então testados para validar o achado identificado no estudo de associação do genoma inteiro. Os mutantes e heterozigotos demonstraram uma maior susceptibilidade à PAIR, especialmente em 8 kHz, tanto através das medidas de emissões otoacústicas por produto de distorção (EOAPD) quanto por potenciais evocados auditivos de tronco cerebral (PEATE). Foi demonstrado por imuno-histoquímica que essa sensibilidade reside nas bandas sinápticas cocleares dos animais mutantes, especialmente em 8 kHz. Este é o primeiro estudo de associação do genoma inteiro para PAIR em camundongos e demonstra o poder dessa estratégia em identificar, de forma tonotópica, a susceptibilidade genética à PAIR.

Page generated in 0.0815 seconds