• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 73
  • 40
  • 4
  • 4
  • 3
  • 2
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 142
  • 42
  • 31
  • 28
  • 25
  • 24
  • 24
  • 22
  • 21
  • 18
  • 18
  • 17
  • 16
  • 16
  • 15
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
81

A New Look at the Cross-sectional Relationship of Self-reported Pain, Function and Walking Performance with Radiographic Wear and other Early Indicators of Total Hip Replacement Failure in Patients with Osteoarthritis

Charlesworth, Jennifer Michelle 16 December 2010 (has links)
Background: Total hip replacement (THR) with post-operative surveillance is recommended for debilitating osteoarthritis (OA). Using self-reported pain, function or walking performance is one alternative to address increasing surveillance demands. Objective: A cross-sectional cohort study to evaluate the associations of pain, function and performance with two radiographic markers of potential THR failure. Participants: 110 patients, median 6 years after THR surgery for OA. Methods: Questionnaires assessed demographics, co-morbidity, arthritis severity, pain, pain catastrophizing, and functional status. Performance was measured using the six minute walk test. THR outcome was assessed radiographically. Results: Few patients had pain, functional impairment or radiographic markers of potential THR failure. A larger percentage of patients with some intermittent pain (10.7 versus 8.6%) and pain iii after walking performance (40.0 versus 27.6%) had higher wear, but these differences were not significant. Conclusion: Measures of pain are potentially important for larger studies aiming to develop alternative methods of post-operative surveillance.
82

A New Look at the Cross-sectional Relationship of Self-reported Pain, Function and Walking Performance with Radiographic Wear and other Early Indicators of Total Hip Replacement Failure in Patients with Osteoarthritis

Charlesworth, Jennifer Michelle 16 December 2010 (has links)
Background: Total hip replacement (THR) with post-operative surveillance is recommended for debilitating osteoarthritis (OA). Using self-reported pain, function or walking performance is one alternative to address increasing surveillance demands. Objective: A cross-sectional cohort study to evaluate the associations of pain, function and performance with two radiographic markers of potential THR failure. Participants: 110 patients, median 6 years after THR surgery for OA. Methods: Questionnaires assessed demographics, co-morbidity, arthritis severity, pain, pain catastrophizing, and functional status. Performance was measured using the six minute walk test. THR outcome was assessed radiographically. Results: Few patients had pain, functional impairment or radiographic markers of potential THR failure. A larger percentage of patients with some intermittent pain (10.7 versus 8.6%) and pain iii after walking performance (40.0 versus 27.6%) had higher wear, but these differences were not significant. Conclusion: Measures of pain are potentially important for larger studies aiming to develop alternative methods of post-operative surveillance.
83

Assessment of atherosclerosis by whole-body magnetic resonance angiography /

Hansen, Tomas, January 2007 (has links)
Diss. (sammanfattning) Uppsala : Univ., 2007. / Härtill 4 uppsatser.
84

An in vitro comparison of working length accuracy between a digital system and conventional film when vertical angulation of the object is variable

Christensen, Shane R. January 2009 (has links)
Thesis (M.S.D.)--Indiana University School of Dentistry, 2009. / Title from PDF t. p. (viewed Aug. 21, 2009) Advisor(s): Mychel Vail, Acting Chair of the Research Committee, Joseph Legan, Kenneth Spolnik, Susan L. Zunt, Edwin Parks. Curriculum vitae. Includes abstract. Includes bibliographical references (leaves 109-120).
85

Influência da presença de materiais metálicos na capacidade diagnóstica de diferentes métodos por imagem - radiografia convencional, radiografia digital e tomografia computadorizada de feixe cônico - investigação in vitro / Influence of the presence of metallic materials in the diagnostic ability of diverse imaging methods - conventional radiograph, digital radiograph and cone-beam computed tomography - in vitro reserach

Liedke, Gabriela Salatino January 2014 (has links)
O objetivo desta tese foi avaliar a interferência da presença de materiais metálicos na imagem radiográfica e tomográfica por meio da análise da adaptação marginal de restaurações e coroas metálicas. Esta investigação resultou em 3 artigos: uma revisão sistemática da literatura para identificar o estado da arte com relação ao uso dos métodos radiográficos; um estudo in vitro comparando o desempenho do filme radiográfico convencional e dos sistemas digitais VistaScan Dürr Dental, Digora Classic Soredex e Express Instrumentarium – com e sem o emprego de filtros para o pós processamento da imagem; e um estudo in vitro avaliando o processamento das imagens da TCFC – utilizando diferentes espessuras de reconstrução. Na revisão sistemática foram incluídos 14 estudos, sendo classificados de baixa ou moderada qualidade, de acordo com os critérios QUADAS de classificação. Na investigação radiográfica (artigo 2), os maiores valores de sensibilidade (0,67 0,83), especificidade (0,81 0,92) e acurácia (0,73 0,86) foram obtidos com radiografias convencionais e imagens digitais originais. Na avaliação tomográfica (artigo 3), os valores da aucROC variaram de 0,60 a 0,72, sendo que o limite inferior do intervalo de confiança mostrou-se abaixo ou muito próximo da linha de referencia. Frente aos resultados, conclui-se que imagens radiográficas originais (convencionais ou digitais) devem ser preferidas para a avaliação de dentes com restaurações metálicas. Quanto à TCFC, mesmo quando se aumenta a espessura de reconstrução da imagem e diminui-se o artefato, ainda assim não há melhora na acurácia do diagnóstico. / The aim of this thesis was to evaluate the interference of the presence of metallic materials on radiographic and tomographic image by assessing misfits tooth and restoration in metal-restored teeth. This investigation resulted in three articles: a systematic review of the literature to identify the state of the art on the use of radiographic methods; an in vitro study comparing the performance of conventional film and digital phosphor plate systems Vistascan Dürr Dental, Digora Classic Soredex and Instrumentarium Express – exported as original images and with the use of post processing filters; and an in vitro study evaluating the post-processing of CBCT images – using diverse reconstruction thicknesses. The systematic review retrived 14 studies, classified as low- / moderate quality based on QUADAS criteria. For radiographic evaluation (article II), higher sensitivity (0.67 0.83), specificity (0.81 0.92) and accuracy (0.73 0.86) values were obtained with conventional and digital original images. For tomographic evaluation (article III), mean aucROC ranged from 0.60 to 0.72, and the analysis of the 95% CI showed the lower bound of the curve bellow or very close to the reference line. Based on the results, it is concluded that original images (conventional or digital) should be preferred for the assessment of teeth with metal restorations. Considering CBCT images, even thought increased reconstruction thickness decreased perceived artifact, it did not improve diagnosis accuracy.
86

Estudo radiográfico digital e densitométrico em mandíbulas de suínos, submetidas a osteotomia com brocas de alta e baixa rotação, com refrigeração líquida

Monti, Lira Marcela [UNESP] 09 December 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:25:20Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-12-09Bitstream added on 2014-06-13T19:52:59Z : No. of bitstreams: 1 monti_lm_me_araca.pdf: 287560 bytes, checksum: 074e03765d9ead5baba4ea3ffcdf36ee (MD5) / Universidade Estadual Paulista (UNESP) / Avaliou-se, por meio de exames radiográficos digitais e densitométricos, a influência do tipo de instrumento rotatório para corte, no processo de reparação óssea após osteotomias em mandíbula de suíno em tempos controlados. Foram utilizados para o estudo oito suínos da raça Large White, com peso corpóreo inicial variando de 25 a 30 Kg. Dois cortes transversais do meio à base de mandíbula direita foram realizados, um por meio de instrumento rotatório de alta rotação e o outro pela ação da baixa rotação, ambos com irrigação líquida. Após períodos pré-estabelecidos (7, 28, 60 e 90 dias) os animais foram sacrificados e suas mandíbulas retiradas para estudos radiográficos digitais diretos e indiretos, pelo sistema DIGORA e ODR e de densitometria óptica por imagens radiográficas pelo sistema CROMOX. Nos períodos iniciais (7 e 28 dias) as densitometrias foram maiores na região das osteotomias realizadas com alta rotação e nos períodos finais (60 e 90 dias) as densitometrias foram maiores nas osteotomias feitas com baixa rotação, indicando uma melhor reparação óssea final quando do uso de baixa rotação. A análise qualitativa do processo de reparação foi feita pelo sistema ODR, que possibilitou a obtenção de imagens digitais tridimensionais e coloridas, permitindo comparação das espessuras ósseas com as de uma cunha de alumínio, evidenciando que aos sessenta dias a reparação óssea estava aparentemente completa. Os histogramas do DIGORA apontaram valores de médias de nível de cinza nas áreas de osteotomia, evidenciando uma maior quantidade de tons de cinza nas osteotomias de alta rotação nos primeiros tempos, e nas osteotomias com baixa-rotação nos tempos finais. / It was evaluated, through digital and densitometric radiographic exams, the influence of the type of rotating instrument for cut, in the process of bony repair after osteotomy in swine jaw in controlled times. They were used for the study eight Large White swines, with initial corporal weight varying from 25 to 30 Kg. Two traverse cuts of the middle to the base of right jaw were accomplished, one through rotating instrument of high rotation and the other for the action of the low rotation, both with liquid irrigation. After established periods (7, 28, 60 and 90 days) the animals were sacrificed and your mandibles retired for direct and indirect digital radiografic studies, for the DIGORA and ODR systems and of optical densitometry for radiographic images for the CROMOX system. In the initial periods (7 and 28 days) the densitometry were larger in osteotomy areas accomplished with high rotation and in the final periods (60 and 90 days) the densitometry were larger in the osteotomy done with low rotation, indicating a better final bony repair when of the use of low rotation. The qualitative analysis of the repair process was made by the ODR system, that made possible obtaining three-dimensional and colored digital images, allowing comparison of the bony thickness with the one of a wedge of aluminum, evidencing that to the sixty days the bony repair was apparently complete. The histograms of DIGORA pointed values of the averages of ash tones in the osteotomy areas, evidencing a larger amount of ash tones in the osteotomy of high rotation in the first times, and in the osteotomy with low-rotation in the final times.
87

Desenvolvimento da peri-implantite induzida por ligadura em diferentes superfícies de implantes osseointegrados. Análise clínica e radiográfica em cães /

Martins, Marilia Compagnoni. January 2000 (has links)
Resumo: Foram avaliados, clínica e radiograficamente, as reações de quatro diferentes superfícies de implante frente ao desenvolvimento e progressão da peri-implantite: Ticp: titânio comercialmente puro; TPS: titânio revestido com plasma spray de titânio; HA: hidroxiapatita; Ost. Superfícies tratadas com ácidos. Para tanto, foram utilizados seis cães, cujos pré-molares inferiores e superiores foram extraídos. Decorridos 90 dias, os implantes foram aleatoriamente colocados, e iniciou-se o controle químico e mecânico do biofilme bacteriano; após o período de osseointegração (90 dias) foram colocados os conectores, e após 45 dias da colocação dos conectores, iniciou-se a indução da peri-implantite por meio de ligaduras de fio de algodão (suspensão do controle do biofilme bacteriano), e os primeiros exames clínicos (profundidade de sondagem, sangramento à sondagem, índices de placa e sangramento, e mobilidade) e radiográficos (perda óssea) foram realizados. Esses parâmetros foram novamente avaliados após 20, 40 e 60 dias, quando da troca das lidaguras. A análise dos resultados não demonstrou diferença significante entre as superfícies, em nenhum dos parâmetros analisados, com exceção da mobilidade (avaliada pelo PeriotestÒ) e perda óssea, que foram menores nos implantes TPS. Concluiu-se que as superfícies apresentam comportamento semelhante durante a indução da peri-implantite, com exceção no parâmetros mobilidade e perda óssea, que apresentaram os implantes TPS com comportamento superior. / Abstract: The reactions of four different implant surfaces were evaluated in regard to the development and progression of peri-implantitis: titanium commercially pure (Ticp), titanium plasma spray (TPS) hidroxiapatite coated (HA) and acid attached surfaces (Ost). Six dogs had their premolars extracted. After 90 days, the implants were ramdonly placed and the dogs receive soft diet, chemical and mechanical plaque control; after the osseointegration period (90 days), the healing abutments were placed. After the healing period (45 days), the plaque control was suspended, and cotton ligatures were installed when the first clinical (probing depth, bleeding on probing, plaque index, bleeding index, and mobility) and radiographic (bone loss) exams were taken. These parameters were re-exanimate after 20, 40 and 60 days, when the ligatures were changed. The results did not show significant differences between the surfaces in any parameter observed except for the mobility (evaluated with PeriotestÒ), and bone loss. These two parameters had the TPS surface with the lower rates. It was conclude that the surfaces show similar behavior during the induction of peri-implantitis, except for the mobility and bone loss parameters witch the TPS implants had better behavior. / Orientador: Ricardo Samih Georges Abi Rached / Coorientador: Elcio Marcantonio Junior / Banca: Rosemary Adriana Chiérice Marcantonio / Banca: Luiz Antonio Pugliesi Alves de Lima / Mestre
88

Influência da presença de materiais metálicos na capacidade diagnóstica de diferentes métodos por imagem - radiografia convencional, radiografia digital e tomografia computadorizada de feixe cônico - investigação in vitro / Influence of the presence of metallic materials in the diagnostic ability of diverse imaging methods - conventional radiograph, digital radiograph and cone-beam computed tomography - in vitro reserach

Liedke, Gabriela Salatino January 2014 (has links)
O objetivo desta tese foi avaliar a interferência da presença de materiais metálicos na imagem radiográfica e tomográfica por meio da análise da adaptação marginal de restaurações e coroas metálicas. Esta investigação resultou em 3 artigos: uma revisão sistemática da literatura para identificar o estado da arte com relação ao uso dos métodos radiográficos; um estudo in vitro comparando o desempenho do filme radiográfico convencional e dos sistemas digitais VistaScan Dürr Dental, Digora Classic Soredex e Express Instrumentarium – com e sem o emprego de filtros para o pós processamento da imagem; e um estudo in vitro avaliando o processamento das imagens da TCFC – utilizando diferentes espessuras de reconstrução. Na revisão sistemática foram incluídos 14 estudos, sendo classificados de baixa ou moderada qualidade, de acordo com os critérios QUADAS de classificação. Na investigação radiográfica (artigo 2), os maiores valores de sensibilidade (0,67 0,83), especificidade (0,81 0,92) e acurácia (0,73 0,86) foram obtidos com radiografias convencionais e imagens digitais originais. Na avaliação tomográfica (artigo 3), os valores da aucROC variaram de 0,60 a 0,72, sendo que o limite inferior do intervalo de confiança mostrou-se abaixo ou muito próximo da linha de referencia. Frente aos resultados, conclui-se que imagens radiográficas originais (convencionais ou digitais) devem ser preferidas para a avaliação de dentes com restaurações metálicas. Quanto à TCFC, mesmo quando se aumenta a espessura de reconstrução da imagem e diminui-se o artefato, ainda assim não há melhora na acurácia do diagnóstico. / The aim of this thesis was to evaluate the interference of the presence of metallic materials on radiographic and tomographic image by assessing misfits tooth and restoration in metal-restored teeth. This investigation resulted in three articles: a systematic review of the literature to identify the state of the art on the use of radiographic methods; an in vitro study comparing the performance of conventional film and digital phosphor plate systems Vistascan Dürr Dental, Digora Classic Soredex and Instrumentarium Express – exported as original images and with the use of post processing filters; and an in vitro study evaluating the post-processing of CBCT images – using diverse reconstruction thicknesses. The systematic review retrived 14 studies, classified as low- / moderate quality based on QUADAS criteria. For radiographic evaluation (article II), higher sensitivity (0.67 0.83), specificity (0.81 0.92) and accuracy (0.73 0.86) values were obtained with conventional and digital original images. For tomographic evaluation (article III), mean aucROC ranged from 0.60 to 0.72, and the analysis of the 95% CI showed the lower bound of the curve bellow or very close to the reference line. Based on the results, it is concluded that original images (conventional or digital) should be preferred for the assessment of teeth with metal restorations. Considering CBCT images, even thought increased reconstruction thickness decreased perceived artifact, it did not improve diagnosis accuracy.
89

Radiografia digital e a tecnica de subtração no monitoramento da desmineralização e remineralização do esmalte dentario / Digital radiography and the subtraction technique for monitoring dental enamel demineralization and remineralization

Bittar-Cortez, Juliana Araujo 25 January 2008 (has links)
Orientador: Francisco Haiter Neto / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-10T07:50:35Z (GMT). No. of bitstreams: 1 Bittar-Cortez_JulianaAraujo_D.pdf: 5858192 bytes, checksum: 3d3d3c7dbc08b34e4b7c483e7316bd88 (MD5) Previous issue date: 2008 / Resumo: O objetivo deste estudo in vitro foi comparar dois protocolos de remineralização em lesões de cárie no esmalte dentário, avaliados por meio de análises de cálcio (Ca) e fósforo (Pi), dureza do esmalte, microscopia de luz polarizada e subtração radiográfica digital (SRD); avaliar a viabilidade da utilização de dois diferentes sistemas de radiografias digitais, placa PSP (photostimulable storage phosphor) e sensor CMOS (complementary metal oxide semicondutor), no diagnóstico de desmineralizações, e a acurácia das radiografias digitais convencionais (RDC) e três métodos de SRD (linear, avançada e logarítmica) no diagnóstico de mudanças minerais; e comparar o ruído e reprodutibilidade das imagens de SRD lineares e logarítmicas produzidas a partir de dois sistemas de radiografias digitais. Para isso, lesões de cárie artificiais foram criadas em 100 superfícies proximais de dentes hígidos. Vinte dentes foram mantidos como controle e oitenta foram submetidos a dois diferentes protocolos de remineralização em 4 e 8 semanas, com a contínua imersão em saliva artificial e um tratamento adicional com flúor. Radiografias digitais foram realizadas antes e depois dos protocolos de remineralização. Cinco examinadores avaliaram a desmineralização e as mudanças minerais nas RDC, dispostas lado a lado, e três métodos da SRD. As análises de Ca / Pi e a colocação dos dentes na solução remineralizante foram considerados como padrão ouro. A média dos tons de cinza e o desvio padrão (DP) no histograma foram também mensurados. As concentrações de Ca e Pi na saliva artificial após os tratamentos foram significativamente menores do que a solução original (p<0,05); e por meio da SRD foi possível verificar diferenças entre as imagens. Entretanto, o teste de dureza e a microscopia de luz polarizada não detectaram nenhuma alteração. O sistema CMOS foi significativamente mais acurado do que a sistema PSP no diagnóstico da desmineralização e mudanças minerais, assim como a SRD linear no diagnóstico de mudanças minerais. Também foram estatisticamente diferentes os valores da média dos níveis de cinza e do DP entre os dois sistemas. Foi concluído que (a) o tratamento adicional de flúor promoveu valores maiores de ganho mineral; (b) a análise de Ca / Pi na saliva artificial foi o método mais sensível na avaliação de alteração mineral; (c) a imagem de SRD linear é um método válido na detecção do aumento de intensidade, como sinal de ganho mineral; e (d) as imagens de SRD utilizando as placas PSP tiveram um menor ruído do que nas imagens geradas pelo sensor CMOS / Abstract: The aim of this in vitro study was to compare two remineralization protocols of artificial carious lesions in enamel, evaluated by Calcium (Ca) and Phosphorus (Pi) analysis, cross-section hardness test, polarized light microscopy and digital subtraction images (DSR); to assess the feasibility of using two different systems of digital radiography, photostimulable storage phosphor (PSP) plate and complementary metal oxide semiconductor (CMOS) sensor on the demineralization diagnosis, and the accuracy of digital conventional radiographs (DCR) and three methods of DSI (linear, advanced and logarithmic) on mineral changes diagnosis; and, to compare noise and reproducibility in linear and logarithmic DSI produced from two digital radiography systems. Artificial caries-like lesions on 100 approximal surfaces of sound teeth were produced. Twenty teeth were kept as control and eighty teeth were subjected to two different remineralization protocols for 4 and 8 weeks, with continuous immersion in artificial saliva, and additional fluoride treatment. Digital radiographs were taken before and after the remineralization protocols. Five examiners assessed demineralization and mineral changes on DCR, placed side by side, and three methods of DSI. Ca / Pi analysis and the placement of the teeth on the remineralization solution was the gold standard. The mean shades of gray and the standard deviation (SD) of the histogram were also assessed. The concentrations of Ca and Pi in the artificial saliva after the treatments were significantly lower than the original solution (p<0.05); and DSR showed differences between the images. However, the Hardness test and polarized light microscopy did not detect any changes. CMOS system was significantly more accurate than PSP system on demineralization and mineral changes diagnosis, and also linear DSR on mineral changes diagnosis. It was also statistically significant different the values of mean shades of gray and SD between both systems. It was concluded that (a) the additional Fluoride treatment provided higher values of mineral gained; (b) Ca / Pi analysis in the artificial saliva were the most sensitive method of mineral change evaluation; (c) linear DSI is a valuable method to disclose an intensity increase, as a sign of mineral gained; and (d) DSR images created from PSP plates had less noise than images produced from CMOS sensor / Doutorado / Radiologia Odontologica / Doutor em Radiologia Odontológica
90

Influência da presença de materiais metálicos na capacidade diagnóstica de diferentes métodos por imagem - radiografia convencional, radiografia digital e tomografia computadorizada de feixe cônico - investigação in vitro / Influence of the presence of metallic materials in the diagnostic ability of diverse imaging methods - conventional radiograph, digital radiograph and cone-beam computed tomography - in vitro reserach

Liedke, Gabriela Salatino January 2014 (has links)
O objetivo desta tese foi avaliar a interferência da presença de materiais metálicos na imagem radiográfica e tomográfica por meio da análise da adaptação marginal de restaurações e coroas metálicas. Esta investigação resultou em 3 artigos: uma revisão sistemática da literatura para identificar o estado da arte com relação ao uso dos métodos radiográficos; um estudo in vitro comparando o desempenho do filme radiográfico convencional e dos sistemas digitais VistaScan Dürr Dental, Digora Classic Soredex e Express Instrumentarium – com e sem o emprego de filtros para o pós processamento da imagem; e um estudo in vitro avaliando o processamento das imagens da TCFC – utilizando diferentes espessuras de reconstrução. Na revisão sistemática foram incluídos 14 estudos, sendo classificados de baixa ou moderada qualidade, de acordo com os critérios QUADAS de classificação. Na investigação radiográfica (artigo 2), os maiores valores de sensibilidade (0,67 0,83), especificidade (0,81 0,92) e acurácia (0,73 0,86) foram obtidos com radiografias convencionais e imagens digitais originais. Na avaliação tomográfica (artigo 3), os valores da aucROC variaram de 0,60 a 0,72, sendo que o limite inferior do intervalo de confiança mostrou-se abaixo ou muito próximo da linha de referencia. Frente aos resultados, conclui-se que imagens radiográficas originais (convencionais ou digitais) devem ser preferidas para a avaliação de dentes com restaurações metálicas. Quanto à TCFC, mesmo quando se aumenta a espessura de reconstrução da imagem e diminui-se o artefato, ainda assim não há melhora na acurácia do diagnóstico. / The aim of this thesis was to evaluate the interference of the presence of metallic materials on radiographic and tomographic image by assessing misfits tooth and restoration in metal-restored teeth. This investigation resulted in three articles: a systematic review of the literature to identify the state of the art on the use of radiographic methods; an in vitro study comparing the performance of conventional film and digital phosphor plate systems Vistascan Dürr Dental, Digora Classic Soredex and Instrumentarium Express – exported as original images and with the use of post processing filters; and an in vitro study evaluating the post-processing of CBCT images – using diverse reconstruction thicknesses. The systematic review retrived 14 studies, classified as low- / moderate quality based on QUADAS criteria. For radiographic evaluation (article II), higher sensitivity (0.67 0.83), specificity (0.81 0.92) and accuracy (0.73 0.86) values were obtained with conventional and digital original images. For tomographic evaluation (article III), mean aucROC ranged from 0.60 to 0.72, and the analysis of the 95% CI showed the lower bound of the curve bellow or very close to the reference line. Based on the results, it is concluded that original images (conventional or digital) should be preferred for the assessment of teeth with metal restorations. Considering CBCT images, even thought increased reconstruction thickness decreased perceived artifact, it did not improve diagnosis accuracy.

Page generated in 0.0724 seconds