• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 609
  • 210
  • 142
  • 133
  • 133
  • 133
  • 133
  • 133
  • 130
  • 41
  • 26
  • 13
  • 9
  • 7
  • 5
  • Tagged with
  • 1396
  • 519
  • 498
  • 469
  • 395
  • 270
  • 225
  • 221
  • 201
  • 195
  • 194
  • 191
  • 190
  • 164
  • 123
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
681

Espectroscopia de raios X utilizando o espalhamento Compton / X-ray spectroscopy using compton scattering

Linke, Arlene 16 September 2008 (has links)
O estudo do espectro de raios X é importante para predizer a qualidade da imagem em sistemas radiográficos. Nesse trabalho usamos um detector semicondutor CdTe para medir os espectros de raios X na faixa de 25 a 120 kVp. Esse detector é pequeno e fácil de ser transportado. As medidas feitas diretamente do tubo de raios X não são aconselháveis devido à alta taxa de fluência que estão acima dos limites de detecção dos detectores usuais e podem causar armadilhamento de carga no detector CdTe. A alternativa é medir os fótons espalhados a 900 a partir de um pequeno objeto espalhador, no nosso caso um cilindro de lucite (PMMA). A partir do espectro espalhado, corrigido para tempo morto e eficiência, e calibrado em energia, efetuamos correções para o ângulo de espalhamento e espalhamento coerente (somente para baixas energias). Só então formalismo de Klein-Nishina para as seções de choque do efeito Compton é aplicado aos espectros, resultando nos espectros primários. Para energia de 120 kVp foi medido um espectro do feixe direto e comparado com o obtido através do espectro espalhado para mesma energia. Para o mesmo feixe, a camada semi-redutora foi avaliada experimentalmente e com o espectro obtido por espalhamento Compton, obtendo-se boa concordância. Observamos na curva de eficiência uma descontinuidade, prevista teoricamente e também observada por outros autores, que deforma o espectro corrigido. Foi aplicado um ajuste polinomial a essa curva, suavizando os espectros obtidos e não alterando sua forma. Os resultados foram satisfatórios e validaram o formalismo apresentado por outros autores, utilizando detectores distintos. / The analysis of x-ray spectra is important to predict image quality in radiographic systems. In this work we used a semiconductor CdTe detector to measure x-ray spectra with a CdTe detector, in the range from 25 to 120 kVp. The CdTe detector is small and portable. The measurements done directly in the primary X rays beam can be difficult because of the high photon fluence rates that cause significant detector photon pile up, and can cause charge trapping in the CdTe. The alternative is to measure the photons scattered at 900 by a small scattering object, in our case a Lucite cylinder (PMMA). Starting from the scattered spectrum, corrected to dead time and efficiency and calibrated in energy, we made corrections for the scattering angle and coherent scattering (only at low energies). After that, the Klein Nishina cross section for Compton scattering are applied to the spectra, resulting in the primary spectra. For the 120 kVp beam a spectrum of the direct beam was measured and compared to the one obtained it through the scattered spectrum for the same energy. The half value layer of the same spectrum was determined experimentally and through the calculated spectrum, and the agreement was very good. The efficiency curve presents a discontinuity, also observed by other authors and predicted theoretically, that deforms the corrected spectrum. A polynomial fitting was adjusted to the efficiency curve, smoothing the corrected spectra without and not altering its form. The results were satisfactory and they validated the methodology presented by other authors, using different detectors.
682

Comparação entre a tomografia computadorizada multislice e a tomografia computadorizada por feixe cônico para identificação de lesões osteolíticas simuladas na cabeça da mandíbula / Comparison between multislice computed tomography and cone beam computed tomography for assessment of simulated mandibular condyle lesions

Marques, Alexandre Perez 04 February 2010 (has links)
A articulação temporomandibular (ATM) apresenta diversas limitações quando se obtém imagens pela radiologia convencional. A tomografia computadorizada é o exame mais indicado, pela alta especificidade e sensibilidade, para o diagnóstico, planejamento cirúrgico e tratamento das suas lesões ósseas. O objetivo deste trabalho consiste na comparação entre a tomografia computadorizada (TC) multislice e a tomografia computadorizada por feixe cônico (TCFC) para avaliação de lesões ósseas simuladas na cabeça da mandíbula. Foram utilizadas 30 cabeças de mandíbulas maceradas onde foram criadas lesões esféricas, com o auxílio de brocas cirúrgicas esféricas de uso odontológico com tamanhos variados (nº 1, 3, 6), em suas cinco porções (anterior, lateral, posterior, medial, superior). As lesões foram submetidas a TC multislice (64 canais) e a TCFC, sendo avaliadas em dois programas de pós-processamento por dois observadores independentemente, sendo um deles em duas ocasiões distintas. Foram utilizados também dois protocolos de análise para exame das imagens quanto à presença ou não de perfuração: reconstrução multiplanar (axial, coronal, sagital) e cortes sagitais e coronais ao longo eixo da cabeça mandibular. Posteriormente, os resultados brutos foram comparados com as lesões presentes na mandíbula macerada (Padrão-Ouro) avaliando a proporção de acertos de cada observador, o grau de especificidade e sensibilidade dos diferentes métodos da TC e da TCFC, e a comparação intra-observador e inter-observadores. O teste z foi utilizado como método estatístico. Os resultados demonstraram não haver diferenças estatisticamente significantes entre os métodos em relação às porcentagens de concordância e que todos estes são validados. Os protocolos para visibilização da região de cabeça da mandíbula foram estabelecidos no intuito de melhorar a identificação da presença de alterações de cada porção da cabeça da mandíbula. Houve maior dificuldade na avaliação de lesões simuladas de pequena dimensão (broca 1) / There are many limitations for image acquisition using conventional radiography of the temporomandibular joint (TMJ) region. Computerized tomography (CT) scan is a better option due to its higher specificity and sensitivity for diagnosis, surgical planning and treatment of bone injuries. The purpose of this study is to compare multislice CT and cone beam computed tomography for evaluation of simulated mandibular condyle lesions. Spherical lesions were created in 30 dry mandibular condiyle with dentist drills (sizes 1, 3, and 6). Condyles were submitted by multislice (64 bits) CT and cone beam computed tomography (CBCT) using two independent software by 2 observants alone, one of them in 2 different occasions, using 2 protocols: axial, coronal and sagittal, and sagittal plus coronal slices for the mandibular condyle visualization. The raw data were compared with the dry mandible (gold standard) regarding the presence of injuries, evaluating the proportion of agreement, degree of specificity and sensitivity of the CT and CBCT and observant analysis. The z test were used as statistical methods. The results showed there are no statistically significant differences between the methods, and the whole methods are validity. It was observed the advantage of the association of axial, coronal and sagittal slices and sagittal plus coronal slices for detection of lesions in mandibular condyles. For some lesions localized in regions, protocols did not show statistically significant differences regarding the proportion of agreement. Protocols were created to improve the visualization of lesions in each region of the mandibular condyle. There was more difficult for assessment small size simulated lesions (# 1).
683

Padronização das tomadas radiográficas periapicais e panorâmicas com finalidade forense / Standards of periapical and panoramic radiographs for forensic examinations

Beaini, Thiago Leite 18 June 2010 (has links)
Existem dificuldades envolvendo as radiografias para as técnicas comparativas de identificação humana. A falta de tecidos moles, o posicionamento do crânio e dos filmes representa obstáculos freqüentes durante as perícias antropológicas. Com objetivo de padronizar e obter imagens de qualidade e reduzir adaptações, testamos exposições, barreiras e outros aspectos radiográficos para a confecção de um protocolo envolvendo radiografias periapicais e panorâmica em crânios esqueletizados. Com a utilização de um dispositivo acrílico desenvolvido para posicionar o crânio, radiografias panorâmicas em diferentes configurações de potência do aparelho foram tomadas. Posteriormente, quatro objetos foram testados para compensar a falta de tecidos moles: uma bolsa térmica, um bloco de cera sete, uma placa de aço zincado e um filme, exposto à luz e processado, que foi mantido entre a película e a tela intensificadora. Para as radiografias periapicais, filmes do tipo E speed Kodak foram expostos por tempos variando entre 0,06 a 0,8 seg nas regiões de molares e incisivos em ambos os arcos. Os filmes foram fixados por posicionadores clínicos estabilizados por um suporte confeccionado com fios metálicos. O tempo de processamento foi de 45 seg de revelação e 10 min. de fixação. As radiografias foram apresentadas a quinze profissionais, de diferentes especialidades, que escolheram os melhores resultados, concluindo que as radiografias panorâmicas com a combinação de 63 Kv e 06 mA e com dois filmes presentes no chassi apresentou melhor qualidade e praticidade. Para as periapicais as exposições de 0,64 seg. no arco superior e 0,8 seg. no arco inferior obtiveram melhor aceitação. Com os resultados obtidos somados aos dados obtidos na literatura, um protocolo foi confeccionado e anexado a essa dissertação. / There are plenty of difficulties surrounding the radiographs for the comparative techniques on human identification. The lack of soft tissue, the skulls and films positioning are a few of the obstacles faced in anthropological studies. With the objectives to standardize, producing high quality images and reducing adaptations, different exposure times, barriers and other aspects involving radiographs were tested in order to establish a protocol involving periapical and panoramic radiographs of dry skulls. With the help of an acrylic stand, specially designed to position the cranium, panoramic radiographs were primarily taken using different preset configurations, then four materials were tested to compensate for lack of soft tissue: a ice pack, a block of dental wax, a metal plate and finally a film exposed to light and processed that was left between the blank film and the intensifying screen. For the periapical radiographs, Kodak E-speed films were exposed to times from 0.06 to 0.8 second at the upper and lower molars and anterior regions. Clinical film holders were used and kept in position by a metal wire device. The processing times were 45 seconds of development and 10 minutes of fixation. The radiographs were presented to a group of fifteen dentists, of several specialties, who selected the best results and concluding that the panoramic radiographs were best taken with the 63 Kv and 06 mA configurations and two films inside the cassette. For the periapical the exposure times of 0.64 sec for the upper arch and 0.8 sec for the lower achieved the best acceptance. The presented results, allied with the data found in the literature a protocol was also prepared and attached to this research.
684

Estudo do membro pélvico do avestruz: considerações anatômicas, radiográficas e histológicas da rotação tibiotársica / Study of hind limb in ostrich: anatomical, radiografic and histological considerations of the tibiotarsica rotation

Oliveira, Roselaine Ponso de 11 March 2005 (has links)
Várias doenças músculo esqueléticas foram observadas em aves de rápido crescimento, sendo o elevado peso corporal, associado a uma estrutura óssea em formação, citados como as principais causas responsáveis pela ocorrência destas doenças, resultando em disfunções do aparelho locomotor. Apesar do estudo do membro pélvico do avestruz merecer a atenção de pesquisadores desde o século XIX, tendo sido descrito no tocante à miologia, principalmente, a osteologia e o estudo radiográfico e morfológico envolvidos na RTT ainda não receberam a devida atenção. O presente trabalho teve como objetivo fazer um estudo anátomo-patológico e radiográfico das estruturas envolvidas na rotação tibiotársica, assim como estudar as alterações articulares através de artrografias e histologia fazendo uma descrição das considerações anatômicas, macroscópicas, microscópicas e radiográficas do membro pélvico do avestruz (African Black). Para este estudo foram utilizadas trinta avestruzes, com idade entre um mês a um ano de idade, apresentando deformidade de membros pélvicos uni ou bilateral. Dessa forma, será possível contribuir para o entendimento desta enfermidade, que tem causado perdas para a estrutiocultura. / Ostrich?s hind limbs study: Anatomical, radiographic and histological considerations of the tibiotarsus rotation. Many skeletal muscles diseases were observed in fast growth, been the hight body wight, to associate with a bone structure in formation citads with the principal responsible cases for ocorrence these deseases, have been disfunction of locomotor arrangment. Despite the fact that the ostrich?s hind limbs have deserved attention from researchers since the 19th century, the myological and osteological descriptions together with the radiographic and morphological study, which involves RTT, have not received any attention yet. This present research intends to make an anatomical, pathological and radiographic study of the structures involved in the tibiotarsus rotation, besides the study of the joint alterations by arthrography and histology, giving one description with anatomical, macroscopic, microscopic and radiographic considerations of the ostrich?s hind limbs. This way, it?ll be possible to contribute to the comprehension of this disease that has caused many losses on the ostrich farm.
685

Estudo experimental dos efeitos da embolização renal com partículas de trisacryl e de polivinil acetato recoberto com polivinil álcool / Experimental study of effects of renal embolization with trisacryl particles and polivinyl alcohol covered polivinyl acetate

Barbosa, Leandro de Assis 06 October 2009 (has links)
A embolização intra-arterial é rotineiramente utilizada na prática clinica como co-adjuvante pré-operatório ou controle de tumores, tratamento de malformações arteriovenosas e outras doenças vasculares. Em vários casos é realizada com uso de partículas de diferentes formas e composições. Um agente embolizante esférico e utilizado com bons resultados é o trisacryl (Embosphere®; BioSphere® Medical). Um novo agente embólico - polivinil acetato esférico cobertas com polivinil álcool (PVAc) foi desenvolvido recentemente no Brasil. Este trabalho tem objetivo de avaliar, após embolização renal, o grau de oclusão vascular, recanalização da luz vascular e a necrose da parede vascular provocados por partículas de PVAc, utilizando como parâmetro partículas de trisacryl. Setenta e nove fêmeas de coelhos do tipo albino New Zealand foram submetidas a cateterização arterial do rim direito; trinta e três animais foram embolizados com trisacryl, trinta e um com PVAc e quinze animais compuseram o grupo de simulação, tendo sido excluídos quatro animais (três trisacryl e um PVAc) devido a óbito precoce. Foram criados cinco subgrupos de seis animais, que foram sacrificados após 48 horas, 5 dias, 10 dias, 30 dias e 90 dias após a embolização. O grupo de simulação seguiu a mesma ordem temporal com três animais em cada grupo. As técnicas de coloração utilizadas foram os métodos de hematoxilina-eosina (HE) e tricrômico de Masson com observação por microscopia óptica. Os resultados mostraram diferença significativa entre o grau de oclusão vascular nos grupos de 5 dias e 10 dias e necrose no grupo de 48 horas em favor do grupo embolizado com PVAc, que apresentou reação tecidual adequada (redução volumétrica e isquemia) e menor grau de recanalização que o trisacryl / Intra-arterial embolization is often utilized in medical practice preoperatively as adjuvant in controlling tumors, treatment of arteriovenous malformations and other vascular diseases. Often times, particles of different forms and compositions are employed. trisacryl (Embosphere®; BioSphere® Medical), a spheric embolic agent, is nowadays used with very satisfactory results. However, a new embolic agent spheric polyvinyl alcohol-covered polivinyl acetate (PVAc)- has been developed in Brazil. This study evaluates the degree of vascular occlusion, vascular recanalization and the necrosis of vascular wall caused by PVAc particles, compared with trisacryl, after renal embolization. Seventy-nine female albine New Zealand rabbits underwent arterial catheterization of the right kidney; Thirty-three animals were embolized with trisacryl, thirty-one with PVAc and fifteen were kept as control group, four animals were excluded (three trisacryl and one PVAc) due to early death. Five subgroups of six animals were created. The animals in the different groups were sacrificed 48 hours, 5 days, 10 days, 30 days and 90 days after embolization. The control group was divided into subgroups of three animals, for the same period of time. Their kidneys were dyed with hematoxylin-eosin (HE) and Masson tricromic and examined using optic microscopy. The results showed a significant difference between the five-day and ten-day groups with regard to the degree of vascular occlusion, and the amount of necrosis in the forty-eight-hour group. Both findings favor the PVAc group, with adequate tissue reaction (ischemia and volumetric reduction) and less recanalization than with trisacryl
686

Kartläggning av hjärnundersökningar med PET/CT på svenska universitetssjukhus : Redovisning av modalitetsuppbyggnad, undersökningsmetod och rekonstruktionsmetod samt stråldosjämförelse mellan PET och SPECT / Mapping of brain imaging with PET/CT in Swedish university hospitals : Presentation of modality structure, examination method and reconstruction method with a comparison of radiation dose between PET and SPECT

Keinan, Sara, Zaklan, Elma January 2019 (has links)
Positron emission tomography/computed tomography (PET/CT) is a method that quantitatively visualizes physiological processes. The most common indications for PET brain are early diagnosis of various dementia types with 18F-Fludeoxyglucose (18F-FDG). The hospital in Jonkoping installed a new PET/CT and brain examinations have not yet been performed. The aim of the study was to map how hospitals in Sweden performed seven selected brain examinations with PET/CT focusing on modality structure, examination method and reconstruction method, with a comparison of radiation dose between PET/CT and single photon emission computed tomography/CT (SPECT)/CT. Out of the nine university hospitals selected, two were excluded. The method was prospective with quantitative approach and data was collected through a protocol. Compilation was made on Excel and the statistics were processed using the Wilcoxon Signed Ranks Test. The result showed similarities, for example reconstruction method and differences, for example fasting time. Effective dose was higher on SPECT than PET in examination of Parkinson's disease, however no significant difference (p = 0,059) was detected. Higher effective doses on SPECT was due to longer half-lives and greater dosages of Ioflupane (123I-Datscan) than 18F-FDG. For further studies, more hospitals and parameters in the protocol can be included.
687

Integrando sistemas de auxílio ao diagnóstico no sistema gerenciador de imagens médicas / Integrating computer-aided diagnosis systems into the picture archiving and communication system

Salomão, Samuel Covas 07 June 2010 (has links)
O avanço tecnológico percebido nos últimos anos proporcionou a utilização em larga escala de equipamentos de aquisição de imagens médicas em formato digital, tais como: raios-X, tomografia computadorizada, ressonância magnética e ultrassom. O uso desses aparelhos na rotina diária de um hospital gera um volume expressivo de dados, o que demanda soluções para armazenamento, distribuição e visualização dessas imagens. Tal papel é desempenhado por sistemas de comunicação e arquivamento de imagens - PACS - através do protocolo de comunicação DICOM, o padrão internacional para codificação e transmissão de imagens médicas. Devido à sua natureza digital, recentemente várias aplicações voltadas para o processamento de imagens médicas foram desenvolvidas, inclusive programas para processar mamografia e tomografia computadorizada de tórax tornaram-se produtos comerciais nos últimos cinco anos. Tais aplicações são conhecidas por CAD ou diagnóstico auxiliado por computador. Sabe-se que soluções CAD podem aprimorar a eficiência e a precisão de diagnósticos clínicos detectando e/ou classificando automaticamente anormalidades e/ou doenças em exames médicos radiológicos. Entretanto, pouco esforço foi realizado no sentido de se integrar as ferramentas CAD a sistemas de comunicação e arquivamente de imagens. Para que o CAD auxilie no diagnóstico médico ele necessita processar imagens digitais que normalmente estão armazenadas no PACS. Atualmente, ainda o padrão para a utilização de sistemas especialistas em processamento de imagens médicas como CAD permanece sendo uma estação de trabalho isolada, e os resultados obtidos dos processamentos não são integrados de forma apropriada a outros sistemas de informação, tais como HIS (Sistema de Informação Hospitalar), RIS (Sistema de Informação em Radiologia) e PACS. O trabalho aqui descrito apresenta uma solução de integração CAD-PACS baseada em bibliotecas livres de de código aberto. Espera-se que essa solução possa contribuir de forma efetiva para um aumento da produtividade e melhoria dos processos na radiologia, beneficiando todo o ambiente hospitalar. / The technology evolution seen in the last years provided large adoption of digital image acquisition equipments, such as: X-rays, computed tomography, magnetic resonance and ultrasound. The use of these devices in daily hospital routine generates an expressive image data volume which demands intelligent solutions for image storage, distribution and visualization. Such role is played by picture archiving and communication systems - PACS - which make extensively use of the DICOM protocol, world industry standard for image transmission and codification in medicine. Due to its digital nature, recently several medical image processing applications were developed and some programs used to process mammography and chest computed tomography images became commercial products in the last five years. These applications are usually known as CAD or computer-aided diagnosis. It\'s known that CAD solutions may improve the diagnosis efficiency and accuracy by detecting and/or classifying automatically abnormalities and/or diseases in radiologic exams. However, little effort was done in the sense of integrating the CAD tools and picture archiving and communication systems. To really assist radiologist diagnosis CAD needs to process digital images that are usually stored in the PACS server. Nowadays, specialist image processing programs like CAD still remains being used on an isolated workstation and the processing results are not integrated in a suitable fashion to other information systems such as HIS (Hospital Information System), RIS (Radiology Information System) and PACS. The work described in this dissertation presents a CAD-PACS integration solution based on free and open source programming libraries. It\'s hoped that this solution may contribute in an effective manner to increase the productivity and improve the radiology workflow, bringing benefits to the whole hospital environment.
688

Utilização dos filtros da radiologia computadorizada para a avaliação da opacificação do forame intervertebral associada às hérnias de disco em cães / Use of computed radiology filters to evaluate the opacification of the intervertebral foramen associated with herniated disc in dogs

Lanza, Luciana Fortunato Burgese 04 December 2012 (has links)
O processamento é uma das principais características da radiografia digital. Diante da frequência da discopatia em cães, a importância do exame radiográfico na investigação inicial desta doença e na orientação de outros exames de imagem (tomografia computadorizada, mielotomografia e imagem por ressonância magnética), buscou-se avaliar a efetiva contribuição das ferramentas de processamento da imagem no diagnóstico das hérnias de disco. Para tanto, foram avaliados 80 forames intervertebrais através da radiologia computadorizada pelos filtros padrão, invertido e realce de borda e a combinação entre esses (padrão e invertido, padrão e realce de borda e realce de borda e invertido) para pesquisa da opacificação do forame intervertebral associada às hérnias de disco em cães. A análise radiográfica foi realizada por dois avaliadores às cegas com tempo de experiência superior a 10 anos em radiodiagnóstico. Foram calculadas as medidas de sensibilidade, especificidade, valores preditivos positivos e negativos, acurácia e razão de verossimilhanças para os respectivos filtros e a combinação destes pelos dois avaliadores. A tomografia computadorizada foi tomada como padrão ouro da detecção de opacificação do forame intervertebral. O coeficiente de kappa e seu respectivo intervalo de 95% de confiança foram utilizados para analisar a concordância dos resultados. Os valores de sensibilidade obtidos pelos avaliadores foram de 58,7% na detecção das opacificações pelo filtro padrão, 52,2% pelo filtro invertido e 50% de sensibilidade no estudo realizado pelo filtro realce de borda. Na combinação entre os filtros padrão e invertido e realce de borda e invertido os valores foram os mesmos com 43,5%, sendo que a sensibilidade do filtro padrão associado com o filtro realce de borda foi de 50%. A acurácia alcançada na detecção das opacificações do forame intervertebral pelos filtros individualmente foi de 78,8% para o filtro padrão, 75% para o filtro invertido e 75,6% para o filtro realce de borda, não apresentando diferenças significativas quando a combinação entre os filtros foi realizada, obtendo-se 76,9% nas associações entre os filtros padrão e invertido e padrão e realce de borda e 75,6% através dos filtros realce de borda e invertido. O processamento da imagem digital pode aumentar a acurácia na detecção das opacificações do forame, no entanto os filtros podem somente realçar uma alteração existente e não aumentar a capacidade de detecção da lesão pelo exame radiográfico simples sendo necessária para tal, a associação de exames de imagem mais sensíveis (mielografia/tomografia computadorizada/ imagem por ressonância magnética). A preferência pessoal na utilização dos filtros também foi comprovada. / Processing is a major feature of digital radiography. Given the frequency of disc disease in dogs, the importance of radiographic examination in the initial investigation of this disease and the guidance of other imaging studies (computed tomography, myelography and magnetic resonance imaging), it was evaluate the effective contribution of the processing tools image in the diagnosis of herniated discs. For this, eigthy intervertebral foramina through were evaluated computed radiography by standart filters, reverse and edge enhancement and the combination of these (standard and inverted pattern, standard and edge enhancement and edge enhancement and inverted) in the investigation of opacification of the intervertebral foramen associated with hernia disc in dogs. Radiographic analysis was performed by two raters blind to time of more than 10 years experience in diagnostic radiology. It was calculated measures of sensitivity, specificity, positive and negative predictive values, accuracy and likelihood ratio for the respective filters and the combination of the two evaluators. Therefore, the CT scan was taken as the gold standard of detection opacification of the intervertebral foramen. The kappa coefficient and its corresponding interval of 95% confidence intervals were used to analyze the correlation of the results. The sensitivity values obtained by the evaluators were 58.7% in detecting the opacities of the standard filter, the filter inverted 52.2% and 50% sensitivity in the study by edge enhancement filter. In combination between standard and inverted filters and edge enhancement and inverted values were the same with 43.5%, and the sensitivity of the filter pattern associated with the filter edge enhancement was 50%. The accuracy achieved in the detection of opacities of the intervertebral foramen by the filters individually was 78.8% for the standard filter, 75% to inverted filter and 75.6% for edge enhancement filter, showing no significant differences when the combination between the filters was performed. yielding 76.9% associations between the filters standard and inverted pattern, and pattern and edge enhancement and 75.6% through the filter edge enhancement and inverted. The digital image processing can increase the accuracy in the detection of opacities foramen, however filters can only highlight a change and not increase the existing capacity of lesion detection by simple radiographic examination is necessary association of more sensitive imaging ( myelography / CT / MRI). Personal preference through the use of filters was also confirmed.
689

Dosimetria em radiologia diagnóstica digital: Uso dos indicadores de exposição de sistemas digitais como estimadores de dose absorvida / Dosimetry in digital diagnostic radiology: use of exposure index of digital systems as absorbed dose estimators

Silva, Thiago Rodrigues da 22 November 2012 (has links)
Os sistemas de radiologia digital, entre eles os baseados em fósforos fotoestimuláveis (sistemas CR como sao conhecidos em radiologia), são cada vez mais comuns na pratica radiológica da cidade de Sao Paulo, seguindo uma tendência mundial. O uso desta tecnologia, que vem substituindo o conjunto tela-filme como sistema de detecção e produção de imagem, permite o uso de uma faixa dinâmica de detecção mais ampla e pode ser prejudicial ou benéfico do ponto de vista da dose absorvida pelo paciente, pois possibilita a obtenção de imagens para superexposições ou subexposições. Para avaliar o contraste obtido na imagem, e, ao mesmo tempo, obter uma estimativa da dose absorvida pelo paciente, todos os fabricantes de sistemas CR incluem no software de analise da imagem um indicador de exposição, que deve se relacionar com a dose absorvida pela placa de fosforo foto-estimulável (Image Plate IP). Estudos que relacionam a razão sinal ruído (SNR) e Dose de Entrada na Pele (DEP), avaliada com câmara de ionização e dosimetria TL, para radiografias de torax (frente e perfil) foram conduzidos empregando técnicas clinicas. Valores de dose (DEP e dose de saída) foram comparados com valores de níveis de cinza e de indicadores de exposição obtidos para as imagens com o CR Agfa CR30-X. Para isso foram utilizados dois simuladores: um simulador homogêneo, com paredes PMMA e preenchido com agua; e um simulador antropomórfico sem os membros superiores e inferiores (RANDO Phantom), no qual foi possível também medir doses internas com dosimetria TL, com irradiações realizadas em laboratório e em ambiente hospitalar. Os resultados mostraram uma relação logarítmica entre o indicador de exposição da Agfa (log of median of histogram - lgM) e a dose de saída do simulador, e uma relação logarítmica da DEP com a mediana dos níveis de cinza de uma regiao da imagem (SAL - Scan Average Level) para ambas as projeções. Também foi possível relacionar o lgM com a DEP, porem, tal relação e dependente da qualidade do feixe. Com o uso de filtros, verificamos que e possível diminuir a DEP mantendo a mesma qualidade da imagem. Neste trabalho foram obtidos valores de DEP na faixa de 0,0995(50) 1,657(51) mGy, e de doses internas entre 0,0074(18) e 0,90(13) mGy. Com isso concluímos que e possível relacionar os indicadores de exposição com a dose absorvida (DEP e dose de saída), e usar o CR como um avaliador de dose absorvida no paciente, quando a qualidade do feixe e conhecida. / The digital radiology systems, among them the system based on photostimulable phosphors (CR systems as they are known in radiology) are increasingly common in radiological practice in Sao Paulo, following a worldwide trend. Using this technology, which is replacing the screen-film as detection system for production of the image, can be detrimental or beneficial in terms of the absorbed dose to the patient, because the dynamic range of these detectors is much wider than the radiographic films, and it is possible to obtain an image with overexposure or underexposure. To evaluate the contrast obtained in the image, and at the same time, obtain an estimate of the absorbed dose to the patient, all manufacturers of CR systems include the evaluation of an exposure index in the image analysis software. This index should be related to the absorbed dose to the phosphor plate (Image Plate- IP). Studies that relate the signal to noise ratio (SNR) and Entrance Skin Dose (ESD), measured with ionization chamber and TL dosimetry for chest X-rays were conducted using clinical techniques, and typical values of dose (ESD and exit dose) were compared with values of gray levels and exposure index obtained with the CR. For this we used two simulators: a homogeneous one made with PMMA walls and filled with water, and an anthropomorphic phantom without the upper and lower limbs (RANDO Phantom), in which it was also possible to measure internal doses with TL dosimetry. The results showed a logarithmic relationship between the Agfa index IgM (log of median of histogram) and the simulator exit dose, and a log relationship between the ESD and the mean gray level of a region of the image (SAL - Scan Average Level ). It was also possible to relate the IgM with ESD, but the relation is dependent on the beam quality. With the use of different filtrations, we verified the possibility of decrease the ESD keeping the same image quality. In this work we obtained ESD values in the range 0.0995(50) 1.657(51) mGy, and internal doses from 0.0074(18) to 0.90(13) mGy.
690

Avaliação morfológica e morfométrica da laringe, faringe e traqueia por meio da radiografia e tomografia computadorizada em cães da raça buldogue inglês / Morphologic and morphometric evaluation of the larynx, pharynx and trachea by radiography and computed tomography in English bulldog

Souto, Cinthia Keiko 24 June 2016 (has links)
A determinação da morfologia e dimensões da traqueia são imprescindíveis para o diagnóstico de hipoplasia e definição do tamanho de stent e escolha de sonda endotraqueal apropriada. O buldogue inglês é o principal representante da hipoplasia traqueal e também da síndrome obstrutiva respiratória do cão braquicefálico (SORB). Assim, o conhecimento dos parâmetros da normalidade nesta raça é essencial para o auxílio diagnóstico destas afecções. O exame radiográfico tem sido a modalidade de eleição, entretanto, com a facilidade de acesso à tomografia computadorizada (TC) e melhor resolução espacial, a padronização dos parâmetros da TC se tornou igualmente importante. A presente pesquisa teve como objetivos revisar a literatura quanto as principais modalidades de diagnóstico por imagem para avaliação da traqueia, aplicar de métodos de mensuração traqueal já descritos por meio do exame radiográfico, sugerir o estudo da avaliação morfológica e morfométrica da traqueia e da faringe em cães buldogue inglês por meio da (TC), comparar os achados obtidos pela TC com os radiográficos, e correlacioná-los com as manifestações clínicas da SORB. Incluíram-se cães da raça buldogue inglês com graus I e II da SORB, os quais foram submetidos ao exame de TC (n=31) e de radiografia computadorizada (n=37) da faringe e traqueia. Ao exame radiográfico, avaliouse a traqueia pelo uso de métodos morfométricos previamente estabelecidos pela literatura, e pela análise morfológica. Pela TC e pelo exame radiográfico, avaliou-se o diâmetro e área transversal da traqueia, assim como sua morfologia. Ainda, avaliou-se pela TC e pelo exame radiográfico, o diâmetro e área transversal da nasofaringe e a espessura e comprimento do palato mole. Por meio do método de Bland-Altman, analisou-se a comparação estatística entre as modalidades de imagem, e por meio do coeficiente de correlação de Spearman, testou-se a correlação entre os achados morfométricos com as manifestações clínicas da SORB. Para tanto, esta pesquisa foi dividida em quatro capítulos, e a metodologia detalhada, resultados, discussões e conclusões estão apresentados individualmente em cada capítulo / Determination of the morphology and dimensions of the trachea are essential for the hypoplasia diagnosis, for stent size definition and appropriate endotracheal tube selection. The English Bulldog is the most affected breed with the tracheal hypoplasia and also brachycephalic obstructive airway syndrome (BOAS). Thus, knowledge of the normal range in this breed is essential to aid diagnosis of these diseases. Radiographic analysis has been the method of choice, however, the increased access to computed tomography (CT) and better spatial resolution, the standardization of CT parameters became equally important. This study aimed to review the literature of the main modalities of diagnostic imaging for evaluation of the trachea, apply tracheal measurement methods already described by radiographic examination, suggest the study of morphological and morphometric evaluation of the trachea and pharynx in English Bulldog by (CT), compare the CT and radiographic results, and correlate them with the clinical manifestations of BOAS. English Bulldog classified as BOAS grade I and II were included and underwent to CT scan (n = 31) and computed radiography (n = 37) of the pharynx and trachea. Radiographic examination evaluated the trachea with morphometric methods previously established in the literature, and with morphological analysis. Diameter and cross-sectional area of the trachea, as well as their morphology was evaluated by CT and the radiograph. Also, the diameter and crosssectional area of the nasopharynx, as well as the thickness and length of the soft palate was evaluated by CT and radiographic examination. Bland-Altman method, was used to analyzed the statistical comparison between imaging modalities, and the Spearman correlation coefficient was used to test morphometric findings with the clinical signs of SORB. Therefore, this study was divided into four chapters, and detailed methodology, results, discussion and conclusions are presented individually in each chapter

Page generated in 0.0724 seconds