• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 6
  • 2
  • 1
  • Tagged with
  • 9
  • 7
  • 7
  • 7
  • 5
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Polymer-Elektrolyt-Membranen: Untersuchungen zur Mikrostruktur und zu den Transporteigenschaften für Protonen und Wasser

Ise, Martin. January 2000 (has links)
Stuttgart, Univ., Diss., 2000.
2

An emission model for the particle-in-cell method

Mudiganti, Jagadish C. Unknown Date (has links) (PDF)
Darmstadt, Techn. University, Diss., 2006.
3

CERN Linac4 - the space charge challenge

Hein, Lutz-Matthias 19 August 2013 (has links)
Im Rahmen eines grossangelegten Modernisierungsprogramms des CERN Beschleunigerkomplexes zur Steigerung der Intensität der Protonenstrahlen wird in einer ersten Phase der Protonenbeschleuniger Linac2 durch einen H− Ionen Beschleuniger Linac4 ersetzt. Um den Ionenstrahl an die einzelnen Beschleunigerelemente des Linac4 anzupassen sind drei Strahltransportsektionen notwendig. Diese sind aufgrund ihrer strahldynamischen Eigenschaften sensitive Stellen für ungewolltes Emittanzwachstum und Teilchenverluste und sind im Schwerpunkt dieser Thesis. Die erste Strahltransportsektion, „Low Energy Beam Transport”(LEBT), befindet sich zwischen der Teilchenquelle und dem ersten Beschleunigerelement, den Radiofrequency Quadrupole (RFQ). Im Rahmen dieser Thesis wurde das LEBT in Betrieb genommen, dessen Strahldynamik rekonstruiert und die Leistungslimitierungen experimentell bestimmt. Der zweite Teil der Thesis ist auf die Auslegung und Strahldynamik der Transfer Linie zwischen Linac4 und dem Proton Synchrotron Booster(PS-Booster) konzentriert. Die Strahldynamik der Transferlinie wurde optimiert und teilweise komplett überarbeitet. Die neue Transferlinie zeichnet sich durch eine verbesserte Emittanzerhaltung, höhere Stabilität der Strahldynamik gegenüber Aufstellungsfehlern und Feldjittern der Magnete und durch eine optimale Anpassung der Strahlparameter an die verschiedenen Injektionsschemata des PS-Boosters aus. Für eine abschließenden „Start-To-End” Simulationen wurden die Strahlcharakteristiken, die bei der Inbetriebnahme des LEBTs bestimmt worden sind, als Anfangsbedingungen für die strahldynamische Simulation von Linac4 einschließlich Transferlinie genutzt. Mit Hilfe dieser „Start-To-End” Simulationen werden kritische Positionen der Strahldynamik identifiziert, die durch Teilchenverluste oder Emittanzwachstum gekennzeichnet sind. Eine besonders kritische Sektion stellt das „Medium Energy Beam Transport” da, dessen Optik auf die neuen Strahlparameter angepasst werden musste. / In the first phase of the upgrade program of the CERN accelerator complex the proton injector Linac2 will be replaced by a new, normal-conducting H− ion Linac, Linac4, allowing a significant increase of the proton flux intensity along the downstream accelerator complex. In the design of Linac4 three beam transport sections are implemented to match the beam between the different accelerator elements and to model the longitudinal pulse structure. These three beam transport sections, which are the most critical locations in terms of beam quality preservation, are in the focus of this thesis. During the work of this thesis the Low Energy Beam Transport (LEBT), which is required to match the source beam to the radiofrequency quadrupole (RFQ), has been commissioned and its beam dynamics re-constructed. The measurement campaign used to reconstruct the LEBT beam dynamics was performed with the aim to prepare the RFQ commissioning and to maximise the LEBT performance. Downstream of the Linac4 accelerator the beam is transported along a 180m long transfer line to the Proton Synchrotron Booster (PS-Booster). The transfer line optics was studied, optimised and sections were completely re-designed. The new transfer line optics is characterised by an improved preservation of the beam emittance, higher stability of the optical solution with respect to alignment errors and field jitters of the transfer line magnets and it is matched to each of the PS-Booster injection schemes. In a concluding ”Start-To-End” simulation based on the measured beam characteristics at the LEBT exit the beam dynamics of the downstream Linac, including the transfer line, was calculated. To minimise particle losses within acceptable emittance preservation the beam optics of the Medium Energy Beam Transport (MEBT) was adapted to the measured beam parameters. This ”Start-To-End” simulation was performed to identify critical sections of the Linac4 beam dynamics and to adjust the commissioning strategies.
4

On space charge driven microbunching instability in bERLinPro

Rädel, Stephanie Diana 07 March 2017 (has links)
Um die zu erwartenden Eigenschaften einer ERLbasierten Synchrotronstrahlungsquelle zu untersuchen, baut das Helmholtz Zentrum Berlin die Testanlage bERLinPro. Die Strahlenergie in diesem Testbeschleuniger beträgt Ekin = 50MeV bei einem Strom von 100 mA. Solch ein hochstromiger Elektronenstrahl im mittleren Bereich der kinetischen Energie ist Raumladungskräften unterworfen. Raumladungskräfte sind eine Quelle von Microbunching Instabilität, die zu einer Dichtemodulation in einer Elektronenverteilung führen kann. Eine solch modulierte Verteilung kann z.B. beim Durchgang durch einen Dipol kohärente, hochbrillante Synchrotronstrahlung emittieren, also Strahlung mit längeren Wellenlängen als die Verteilung. Im Rahmen dieser Arbeit wird sowohl das Auftreten, als auch die Einsatzmöglichkeit von Microbunching Instabilität in bERLinPro untersucht. Es ist geplant, bERLinPro bei zwei verschiedenen Betriebsarten (normaler Betriebsmodus und KurzPulsModus) zu betreiben. Im Rahmen dieser Arbeit wurden zum ersten Mal nummerische Simulationen des Testbeschleunigers von dessen Anfang bis dessen Ende durchgeführt, die sowohl von analytischen Rechnungen unterstützt als auch mit ihnen verglichen wurden. Ausführlich werden sowohl der Simulationscode, das Programm zur Nachbearbeitung der nummerischen Untersuchungen als auch ein SigmamatrixTrackingSkript beschrieben. Dieses dient als Basis für analytische Rechnungen, dass zusätzlich auch Impedanz Berechnungen und Gain Rechnungen beinhalten. Für den KurzPulsModus können nur analytische Rechnungen betrachtet werden, denn das entsprechende Design der Maschine, wie auch die Anpassung der Phase im Linearbeschleuniger, sind Gegenstand aktueller Untersuchungen. / To investigate the expected properties of an ERLbased synchrotron light source, the Helmholtz Zentrum Berlin (HZB) is building the test facility bERLinPro. The beam energy of the test facility amounts to Ekin = 50MeV at a current of 100 mA. Such a high current electron beam with a medium bunch energy underlies space charge forces. These are a source of microbunching instability which can lead to a density modulation of the electron distribution in the electron bunch. These modulated bunches can emit highbrilliance coherent synchrotron radiation; radiation with wavelengths longer than the bunch, i.e. by passing a dipole. In the framework of this thesis both the occurence and the possible application of microbunching instability are investigated in bERLinPro. Planes are to run bERLinPro in two different operation modes: Standard operation mode and short pulse mode. In the context of this thesis, numerical start-to-end simulations for standard operation mode have been carried out for the first time. Both were compared and supported with analytical calculations. Elaborated descriptions of simulation codes and postprocessing tools for numerical investigation are described, as well as a sigma matrix tracking script as basis for analytical investigation, including impedance and gain calculations. Since current investigations include lattice design and linac phase adjustments for the short pulse mode, only analytical calculation could be considered for this operation mode.
5

Transient Avalanche Oscillation of IGBTs Under High Current / Transient Avalanche Oszillationen von IGBTs unter hohem Strom

Hong, Tao 04 September 2015 (has links) (PDF)
Radio frequency oscillations up to several hundreds of MHz were observed during turn-off the high-current conducting IGBTs. They are described in this work as Transient Avalanche oscillations. Other than PETT oscillations that happen in the tail current phase, this oscillation appears during the rise of collector-emitter voltage VCE and during the fall of the collectoremitter current ICE. The turn-off process of IGBTs are investigated with the help of measurements, the circuit- and device-simulations to reveal the working mechanisms of transient high-frequency oscillations. For the first time the Transient Avalanche Oscillation is successfully reproduced with computer simulation, which allows the further investigation on the influences of individual parameters. The participation of IMPATT mechanism in Transient Avalanche oscillation is demonstrated. The interaction between IMPATT mechanism und PETT mechanism during the setting up of depletion region in IGBTs was investigated. Measures to suppress such oscillation are discussed on the levels of chip design, module design and the driver concept. Supplying electron current during critical phase is found to be an effctive method to avoid the dynamic avalanche and the TA-oscillation. / Radio Frequenz Oszillationen bis zu mehreren hundert MHz wurden während des Abschaltens von Hochstrom leitenden IGBTs beobachtet. Sie werden in dieser Arbeit als Transient Avalanche Oscillationen beschrieben. Anders als PETT Oszillationen, die in der Tail-Strom Phase vorkommen, erscheint diese Oszillation während des Anstiegs der Kollektor-Emitter-Spannung VCE und des Fallens des Kollektor-Emitter Stroms ICE. In dieser Arbeit werden die Abschaltvorgänge von IGBTs mit Hilfe von Messungen, Schaltungs- bzw. Device-Simulationen untersucht, um die Wirkungsmechanismen der transient erscheinenden hochfrequenten Oszillationen zu erklären. Es ist erstmals gelungen solche Transient Avalanche Oszillationen mit der Simulation zu reproduzieren und anschließend die Einflüsse einzelner Parameter zu untersuchen. Die Beteiligung des IMPATT Mechanismus an der Transient Avalanche Oszillation wurde nachgewiesen. Die Interaktion von IMPATT und PETT während Aufbau der Raumladungszone im IGBT wurde untersucht. Maßnahmen zur Unterdrückung der Oszillation werden auf den Ebenen von Chip-Design, Modulauslegung und der Treiberschaltung diskutiert. Das Zuführen des Elektrostromes während der kritischen Phase wird als ein effective Methode zur Vermeidung der TA-Oscillation nachgewiesen.
6

Überschlagsverhalten von Gas-Feststoff-Isoliersystemen unter Gleichspannungsbelastung

Hering, Maria 28 April 2016 (has links) (PDF)
Gasisolierte Systeme im Gleichspannungsbetrieb vereinen für Anwendungen moderner Energieübertragung die Forderungen nach kleinräumigen Anlagen und verlustarmem Energietransport über große Entfernungen. Für einen zuverlässigen und sicheren Betrieb muss das Verhalten der eingesetzten Gas-Feststoff-Isolierung im technologischen System bis an die Grenzen des Isolationsvermögens bekannt sein. Gegenstand der vorliegenden Arbeit ist deshalb das Überschlagsverhalten von Gas-Feststoff-Isoliersystemen unter Gleichspannungsbelastung. Dabei stehen zwei wesentliche Einflussfaktoren im Vordergrund: die Temperatur, motiviert durch reale Stromwärmeverluste, und eine feste Störstelle auf der Gas-Feststoff-Grenzfläche, motiviert durch in der Praxis nicht völlig auszuschließende, metallische Partikel. Die Effekte dieser beiden Parameter auf die Feldverteilung, die Oberflächen- und Raumladungsbildung sowie das Isolationsvermögen bei Gleichspannung werden zunächst in zwei Versuchsanordnungen separat experimentell untersucht. Anschließend wird deren Zusammenwirken und gegenseitige Beeinflussung im Gesamtsystem analysiert. Die betriebsbedingte Erwärmung der Leiter gasisolierter Systeme führt zu einer inhomogenen Temperaturverteilung, die sich auf die Eigenschaften der Isolierstoffe Gas und Epoxidharz auswirkt. Die von der Temperatur abhängige Leitfähigkeit der Feststoffisolatoren führt zu einer temperaturabhängigen Feldverteilung, bei der sich der Ort der Höchstfeldstärke verschiebt. Dabei kann sich der Absolutwert der Höchstfeldstärke erhöhen und somit das Isolationsvermögen verringern. Gleichzeitig weist das Isoliergas nahe des erwärmten Leiters lokal eine geringere Dichte und damit eine geringere dielektrische Festigkeit auf. Die thermisch bedingte Minderung des Isolationsvermögens bei Gleichspannung beträgt in der untersuchten Anordnung (25 ... 35) %. In den schwach inhomogenen Feldern gasisolierter Anlagen erweisen sich metallische Partikel auf Isolatoren ab drei Millimetern Länge als besonders kritisch. Bei einem Gasdruck unterhalb von 0,3 MPa setzen an den Partikelspitzen zum Teil bereits ab 50 % der Durchschlagsspannung ohne Partikel Teilentladungen ein, sodass die Koronastabilisierung zu einer vergleichsweise hohen Überschlagsspannung führt. Durch diese stabilen Glimmentladungen kann die Störstelle bei Gleichspannung durch die üblichen Detektionsverfahren jedoch nicht zweifelsfrei nachgewiesen werden. Oberhalb von 0,3 MPa treten vor dem Überschlag keine Teilentladungen auf. Aufgrund der fehlenden Koronastabilisierung kann die Isolationsfestigkeit durch einen erhöhten Gasdruck nicht oder nur stark unterproportional gesteigert werden. Die mit der Modellanordnung gewonnenen Erkenntnisse sind nachweislich auf Isolatoren kommerzieller Anlagen übertragbar. Das in der vorliegenden Arbeit untersuchte Überschlagsverhalten von Gas-Feststoff-Isoliersystemen unter Gleichspannungsbelastung wird maßgeblich durch die Temperaturverteilung und durch feste Störstellen auf der Grenzfläche beeinflusst. Oberflächen- und Raumladungen verändern das üblicherweise ohmsch-kapazitiv beschriebene Verhalten des Isolierstoffsystems bei Gleich- und Mischspannungsbelastung. Der Einfluss zusätzlicher Ladungsträger auf die stark temperaturabhängige Feldumbildung demonstriert, dass das Isoliergas in diesem Fall mit teilchendichte- und feldstärkeabhängigen Drift- und Diffusionsprozessen zur Modellierung des transienten Verhaltens von Gleichspannungssystemen berücksichtigt werden muss. Die Untersuchung des Systemverhaltens an den Grenzen des Isolationsvermögens ist wichtiger Bestandteil bei der Entwicklung innovativer Technologien der modernen Energieübertragung bei steigender Übertragungsleistung. / DC operated gas-insulated systems combine the demand for space saving installations and lowloss energy transport over long distances for applications of recent energy transmission. In order to ensure a reliable and safe operation, the behaviour of the gas-solid insulation, which is used in the technological system, has to be known up to the limits of the insulation properties. Hence, this thesis deals with the flashover behaviour of gas-solid insulation systems under DC voltage stress. Thereby, it focuses on two main influence factors: the temperature, due to real current heat losses, and an adhesive defect on the gas-solid interface, due to metallic particles that cannot be fully excluded in practice. Firstly, it is investigated experimentally in two test arrangements, how each parameter separately affects the electrical field distribution, the surface and volume charge accumulation and the insulation performance under DC voltage stress. Following that, their interaction and mutual influence is analysed in the whole system. Due to operating currents, the heating of the conductors in gas-insulated systems causes an inhomogeneous temperature distribution, that affects the properties of the insulating materials gas and epoxy resin. The temperature-dependent conductivity of the solid insulators leads to a temperature-dependent field distribution. Thereby, the location of the highest field strength is shifted. Since the absolute value of the highest field strength can increase, the insulation performance can decrease. Simultaneously, the insulating gas close to the heated conductor locally has a lower gas density and therefore a lower dielectric strength. The thermal related reduction of the insulation performance under DC voltage stress amounts to (25 ... 35) % in the investigated arrangement. Metallic particles, with a length of more than three millimetres and adhering on spacers, turn out to be particularly critical in the weakly inhomogeneous field of gas-insulated systems. At pressures below 0,3 MPa, partial discharges at the particle tips partly ignite already at 50 %of the breakdown voltage without a particle. The corona stabilisation leads to a relatively high flashover voltage. However, due to these stable glow discharges under DC voltage stress, the defect can not be unequivocally proven by usual detection methods. Above 0,3 MPa, no partial discharges occur before the flashover. Due to the missing corona stabilisation, with a higher gas pressure, the insulation strength is not or only disproportionately low increasing. The findings gained with the model arrangement are evidently applicable to spacers of commercial installations. The flashover behaviour of gas-solid insulation systems under DC voltage stress, examined in this thesis, is influenced significantly by the temperature distribution and adhesive particles on the interface. Surface and volume charges change the generally resistive-capacitive described behaviour of the insulation system under DC and superimposed voltage stress. The influence of additional charge carriers on the strongly temperature-dependent field transition demonstrates, that in this case, the insulating gas with its drift and diffusion processes, depending on the particle density and the field strength, has to be considered, when modelling the transient behaviour of DC operated systems. Investigating the system behaviour to the limits of the insulation properties is a crucial element of developing innovative technologies of the modern energy transmission at increasing transmissions powers.
7

Überschlagsverhalten von Gas-Feststoff-Isoliersystemen unter Gleichspannungsbelastung

Hering, Maria 11 March 2016 (has links)
Gasisolierte Systeme im Gleichspannungsbetrieb vereinen für Anwendungen moderner Energieübertragung die Forderungen nach kleinräumigen Anlagen und verlustarmem Energietransport über große Entfernungen. Für einen zuverlässigen und sicheren Betrieb muss das Verhalten der eingesetzten Gas-Feststoff-Isolierung im technologischen System bis an die Grenzen des Isolationsvermögens bekannt sein. Gegenstand der vorliegenden Arbeit ist deshalb das Überschlagsverhalten von Gas-Feststoff-Isoliersystemen unter Gleichspannungsbelastung. Dabei stehen zwei wesentliche Einflussfaktoren im Vordergrund: die Temperatur, motiviert durch reale Stromwärmeverluste, und eine feste Störstelle auf der Gas-Feststoff-Grenzfläche, motiviert durch in der Praxis nicht völlig auszuschließende, metallische Partikel. Die Effekte dieser beiden Parameter auf die Feldverteilung, die Oberflächen- und Raumladungsbildung sowie das Isolationsvermögen bei Gleichspannung werden zunächst in zwei Versuchsanordnungen separat experimentell untersucht. Anschließend wird deren Zusammenwirken und gegenseitige Beeinflussung im Gesamtsystem analysiert. Die betriebsbedingte Erwärmung der Leiter gasisolierter Systeme führt zu einer inhomogenen Temperaturverteilung, die sich auf die Eigenschaften der Isolierstoffe Gas und Epoxidharz auswirkt. Die von der Temperatur abhängige Leitfähigkeit der Feststoffisolatoren führt zu einer temperaturabhängigen Feldverteilung, bei der sich der Ort der Höchstfeldstärke verschiebt. Dabei kann sich der Absolutwert der Höchstfeldstärke erhöhen und somit das Isolationsvermögen verringern. Gleichzeitig weist das Isoliergas nahe des erwärmten Leiters lokal eine geringere Dichte und damit eine geringere dielektrische Festigkeit auf. Die thermisch bedingte Minderung des Isolationsvermögens bei Gleichspannung beträgt in der untersuchten Anordnung (25 ... 35) %. In den schwach inhomogenen Feldern gasisolierter Anlagen erweisen sich metallische Partikel auf Isolatoren ab drei Millimetern Länge als besonders kritisch. Bei einem Gasdruck unterhalb von 0,3 MPa setzen an den Partikelspitzen zum Teil bereits ab 50 % der Durchschlagsspannung ohne Partikel Teilentladungen ein, sodass die Koronastabilisierung zu einer vergleichsweise hohen Überschlagsspannung führt. Durch diese stabilen Glimmentladungen kann die Störstelle bei Gleichspannung durch die üblichen Detektionsverfahren jedoch nicht zweifelsfrei nachgewiesen werden. Oberhalb von 0,3 MPa treten vor dem Überschlag keine Teilentladungen auf. Aufgrund der fehlenden Koronastabilisierung kann die Isolationsfestigkeit durch einen erhöhten Gasdruck nicht oder nur stark unterproportional gesteigert werden. Die mit der Modellanordnung gewonnenen Erkenntnisse sind nachweislich auf Isolatoren kommerzieller Anlagen übertragbar. Das in der vorliegenden Arbeit untersuchte Überschlagsverhalten von Gas-Feststoff-Isoliersystemen unter Gleichspannungsbelastung wird maßgeblich durch die Temperaturverteilung und durch feste Störstellen auf der Grenzfläche beeinflusst. Oberflächen- und Raumladungen verändern das üblicherweise ohmsch-kapazitiv beschriebene Verhalten des Isolierstoffsystems bei Gleich- und Mischspannungsbelastung. Der Einfluss zusätzlicher Ladungsträger auf die stark temperaturabhängige Feldumbildung demonstriert, dass das Isoliergas in diesem Fall mit teilchendichte- und feldstärkeabhängigen Drift- und Diffusionsprozessen zur Modellierung des transienten Verhaltens von Gleichspannungssystemen berücksichtigt werden muss. Die Untersuchung des Systemverhaltens an den Grenzen des Isolationsvermögens ist wichtiger Bestandteil bei der Entwicklung innovativer Technologien der modernen Energieübertragung bei steigender Übertragungsleistung. / DC operated gas-insulated systems combine the demand for space saving installations and lowloss energy transport over long distances for applications of recent energy transmission. In order to ensure a reliable and safe operation, the behaviour of the gas-solid insulation, which is used in the technological system, has to be known up to the limits of the insulation properties. Hence, this thesis deals with the flashover behaviour of gas-solid insulation systems under DC voltage stress. Thereby, it focuses on two main influence factors: the temperature, due to real current heat losses, and an adhesive defect on the gas-solid interface, due to metallic particles that cannot be fully excluded in practice. Firstly, it is investigated experimentally in two test arrangements, how each parameter separately affects the electrical field distribution, the surface and volume charge accumulation and the insulation performance under DC voltage stress. Following that, their interaction and mutual influence is analysed in the whole system. Due to operating currents, the heating of the conductors in gas-insulated systems causes an inhomogeneous temperature distribution, that affects the properties of the insulating materials gas and epoxy resin. The temperature-dependent conductivity of the solid insulators leads to a temperature-dependent field distribution. Thereby, the location of the highest field strength is shifted. Since the absolute value of the highest field strength can increase, the insulation performance can decrease. Simultaneously, the insulating gas close to the heated conductor locally has a lower gas density and therefore a lower dielectric strength. The thermal related reduction of the insulation performance under DC voltage stress amounts to (25 ... 35) % in the investigated arrangement. Metallic particles, with a length of more than three millimetres and adhering on spacers, turn out to be particularly critical in the weakly inhomogeneous field of gas-insulated systems. At pressures below 0,3 MPa, partial discharges at the particle tips partly ignite already at 50 %of the breakdown voltage without a particle. The corona stabilisation leads to a relatively high flashover voltage. However, due to these stable glow discharges under DC voltage stress, the defect can not be unequivocally proven by usual detection methods. Above 0,3 MPa, no partial discharges occur before the flashover. Due to the missing corona stabilisation, with a higher gas pressure, the insulation strength is not or only disproportionately low increasing. The findings gained with the model arrangement are evidently applicable to spacers of commercial installations. The flashover behaviour of gas-solid insulation systems under DC voltage stress, examined in this thesis, is influenced significantly by the temperature distribution and adhesive particles on the interface. Surface and volume charges change the generally resistive-capacitive described behaviour of the insulation system under DC and superimposed voltage stress. The influence of additional charge carriers on the strongly temperature-dependent field transition demonstrates, that in this case, the insulating gas with its drift and diffusion processes, depending on the particle density and the field strength, has to be considered, when modelling the transient behaviour of DC operated systems. Investigating the system behaviour to the limits of the insulation properties is a crucial element of developing innovative technologies of the modern energy transmission at increasing transmissions powers.
8

Space Charge Modeling at the Integer Resonance for the CERN PS and SPS

Titze, Malte 11 June 2020 (has links)
Die elektromagnetische Wechselwirkung der Teilchen untereinander, wie sie typischerweise in einem Strahl hoher Intensität in den CERN Beschleunigern auftritt, kann in Langzeitsimulationen nicht vernachlässigt werden. Simulationen sind insbesondere notwendig, um diese Beschleuniger zu optimieren und die zugrundeliegende kohärente und inkohärente Dynamik besser zu verstehen. Die Auswirkungen der unumgänglichen Vereinfachungen in der Modellierung der komplizierten Dynamik müssen deshalb untersucht werden. Wir gehen diese Aufgabe an, indem wir sechs verschiedene Strahlführungsmodelle am CERN Proton Synchrotron (PS) und am Super Proton Synchrotron (SPS) untersuchen, die wir dynamisch in der Nähe von horizontalen Integer-Resonanzen operieren. Die sechs Modelle, welche insgesamt in den beiden bewährten Programmpaketen MAD-X und PyOrbit implementiert sind, werden mit den jeweiligen Messungen an beiden Maschinen verglichen, wobei der Schwerpunkt hier auf dem PS liegt. / In long-term tracking simulations of high-intensity beams which are typical in the CERN accelerators, the electromagnetic interaction between the individual particles can not be neglected. Simulations are required to optimize the performance of the accelerators, and to better understand the involved coherent and incoherent dynamics. The impact due to the unavoidable simplifications when modeling the complex dynamics must therefore be studied. We approach this task by examining six different tracking models, applied to the CERN Proton Synchrotron (PS) and the Super Proton Synchrotron (SPS), both of which were dynamically operated near horizontal integer resonances. The six models, which are overall implemented in the well-known program packages MAD-X and PyOrbit, are compared to beam-based measurements on both machines, with the PS as the main emphasis.
9

Transient Avalanche Oscillation of IGBTs Under High Current

Hong, Tao 11 March 2015 (has links)
Radio frequency oscillations up to several hundreds of MHz were observed during turn-off the high-current conducting IGBTs. They are described in this work as Transient Avalanche oscillations. Other than PETT oscillations that happen in the tail current phase, this oscillation appears during the rise of collector-emitter voltage VCE and during the fall of the collectoremitter current ICE. The turn-off process of IGBTs are investigated with the help of measurements, the circuit- and device-simulations to reveal the working mechanisms of transient high-frequency oscillations. For the first time the Transient Avalanche Oscillation is successfully reproduced with computer simulation, which allows the further investigation on the influences of individual parameters. The participation of IMPATT mechanism in Transient Avalanche oscillation is demonstrated. The interaction between IMPATT mechanism und PETT mechanism during the setting up of depletion region in IGBTs was investigated. Measures to suppress such oscillation are discussed on the levels of chip design, module design and the driver concept. Supplying electron current during critical phase is found to be an effctive method to avoid the dynamic avalanche and the TA-oscillation. / Radio Frequenz Oszillationen bis zu mehreren hundert MHz wurden während des Abschaltens von Hochstrom leitenden IGBTs beobachtet. Sie werden in dieser Arbeit als Transient Avalanche Oscillationen beschrieben. Anders als PETT Oszillationen, die in der Tail-Strom Phase vorkommen, erscheint diese Oszillation während des Anstiegs der Kollektor-Emitter-Spannung VCE und des Fallens des Kollektor-Emitter Stroms ICE. In dieser Arbeit werden die Abschaltvorgänge von IGBTs mit Hilfe von Messungen, Schaltungs- bzw. Device-Simulationen untersucht, um die Wirkungsmechanismen der transient erscheinenden hochfrequenten Oszillationen zu erklären. Es ist erstmals gelungen solche Transient Avalanche Oszillationen mit der Simulation zu reproduzieren und anschließend die Einflüsse einzelner Parameter zu untersuchen. Die Beteiligung des IMPATT Mechanismus an der Transient Avalanche Oszillation wurde nachgewiesen. Die Interaktion von IMPATT und PETT während Aufbau der Raumladungszone im IGBT wurde untersucht. Maßnahmen zur Unterdrückung der Oszillation werden auf den Ebenen von Chip-Design, Modulauslegung und der Treiberschaltung diskutiert. Das Zuführen des Elektrostromes während der kritischen Phase wird als ein effective Methode zur Vermeidung der TA-Oscillation nachgewiesen.

Page generated in 0.0565 seconds