161 |
Collective Short Wavelength Dynamics in Phospholipid Model Membranes - with Inelastic Neutron Scattering / Kollektive Dynamik in Phospholipid Modellmembranen bei kurzen Wellenlängen - mit Inelastischer NeutronenstreuungBrüning, Beate-Annette 02 December 2008 (has links)
No description available.
|
162 |
Capteurs de corrosion à fibre optique pour la surveillance répartie d’ouvrages en béton armé / Distributed corrosion sensing in reinforced concrete structures by optical fiber sensingAli Alvarez, Shamyr Sadat 19 September 2016 (has links)
La corrosion des armatures de renforcement des structures en béton représente un enjeu socio-économique majeur. Sa détection et le suivi de son évolution constituent un défi pour la recherche appliquée. Les techniques standards non destructives de détection de corrosion mettent en œuvre des procédés indirects tels la mesure d’impédance, de potentiels, ou par ultrasons. Leurs capacités d’auscultation sont limitées dans l’espace (notamment en profondeur), leur coût reste élevé dans un contexte de maintenance périodique et elles conduisent à des paramètres d’interprétation complexe. Des progrès sont nécessaires dans la détection et l’analyse fiable de la progression des processus de corrosion. Dans ce travail, nous présentons une nouvelle méthode pour détecter la corrosion et le suivi de son évolution, basée sur l’observation directe des changements intervenant à l’interface fer-béton par Capteur à Fibre Optique (CFO). L'attaque par corrosion de la surface de l'armature dépend de plusieurs paramètres électrochimiques (température, pH, carbonatation, présence de chlorures, contamination biologique, etc.). Deux comportements mécaniques à l'interface fer-béton sont distingués. Dans le premier cas (carbonatation), le produit d'oxydation du métal reste à l'interface et augmente la pression interne, pouvant conduire à la fissuration de la couche de béton extérieure. Dans le second cas (piqures), les ions métalliques sont évacués hors de la structure avec comme conséquence une réduction de section des barres d'armature (affaiblissement du renforcement). Un CFO innovant est proposé dans le but de localiser et quantifier les deux types de corrosion précités. Le principe consiste à observer l’impact direct de la corrosion sur l’état de déformation d’une fibre optique préalablement précontrainte par construction. Deux procédés métrologiques sont étudiés : Bragg et réflectométrie fréquentielle (Optical Frequency-Domain Reflectometry - OFDR). Des tests de corrosion accélérée montrent la faisabilité du procédé. Une procédure de fabrication simplifiée et à coût optimisé est proposée pour la surveillance in situ et répartie des structures de génie civil, dans une perspective future de maintenance conditionnée. / Corrosion of reinforced bars (rebars) in concrete structures remains a major issue in civil engineering works, being its detection and evolution a challenge for the applied research. Usual non-destructive corrosion detection methods involve impedance, potential or ultra-sonic indirect measurements of complex interpretation. Besides, they are restricted to near-surface examinations and the maintenance cost is still high (scheduled maintenance). Many efforts remain to be done to survey the onset and progression of corrosion processes in a reliable way. In this work, we present a new methodology to detect the onset of corrosion and to monitor its evolution, based on the direct observation of rebar–concrete interface changes by the use of an Optical Fiber Sensor (OFS). The corrosion attack over rebar surface depends on several physical, chemical and electrochemical parameters (temperature, pH, presence of chlorides/CO2, biological contamination, etc.). Two types of mechanical behavior and described. In the first case (carbonation), metal oxidation products stay at the interface and increase internal pressure, potentially leading to a crack of the external concrete layer. In the second case (pitting), metal ions are evacuated out of the structure, leading to a reduction of the rebar section (structural weakness). An innovative sensor design is proposed with the purpose of localizing and quantifying the amount of both corrosion types. The basic principle consists in measuring the impact of corrosion over the state of strain of a prestressed optical fiber. Two metrological techniques are used: Fiber Bragg Grating (FBG) and Optical Frequency-Domain Reflectometry (OFDR). Accelerated corrosion tests were performed in electrolytic solutions for both kinds of corrosion types (pitting and carbonation) and provide a proof-of-concept for the technique. A low-cost, simplified manufacturing procedure is proposed with the aim to provide distributed and in situ Structural Health Monitoring (SHM), suitable for future Condition-Based Maintenance (CBM) of civil engineering concrete structures.
|
163 |
Neutron tunneling in nanostructured systems: isotopical effectMatiwane, Aphiwe 11 1900 (has links)
Tunneling phenomenon has been studied since the time of Sir Isaac Newton. In the case of neutron tunneling phenomenon, it is the quantum mechanics wave-particle duality which manifests itself. In this case, particularly, the neutron wave-packet under total reflection condition suffers the so-called frustrated total reflection as known in standard optics. More accurately, this tunneling phenomenon shows itself via sharp dips in the plateau of total reflection. The prerequisite to observe such quantum mechanics phenomenon lies within a thin film Fabry-Perot resonator configuration. This thin film Fabry-Perot resonator geometry consists of two reflecting mirrors separated by a transparent material from a neutron optics viewpoint. In view of the specific neutron scattering properties related to the spin of the neutron wave-packet. As a direct proof, isotopic nickel based thin films Fabry-Perot resonator have been fabricated by depositing thin film of nickel by ion beam sputtering. The vacuum chamber was pumped down to the pressure of 10-8 mbar and deposition was performed at pressure of 2x10-4 mbar. The deposition rate was kept at 1.5 nm / minute and thickness layers were monitored by a calibrated quartz microbalance. Unpolarized neutron reflectometry measurements were carried out at the ORPHEE reactor using the time-of-flight EROS reflectometer. The incidence neutron wavelength varied between 3 – 25 Å. The grazing angle and angular resolution were of the order of 0.8˚ and 0.05 respectively. The software program, a Matlab routine for the simulation of specular X-ray and neutron reflectivity data with matrix technique, was employed to simulate the phenomenon and thereafter the experimentally obtained data and calculated (theoretical) data were compared. From the analysis of the comparison, a conclusion was drawn about the agreement between experimental data and theoretical data. The tunneling phenomenon has been observed in nanostructured isotopic nickel based thin film Fabry-Perot resonator. It manifested itself by the existence of dips, tunneling resonances, in the total reflection plateau due to quasi-bound states in the isotopic nickel based thin film Fabry-Perot resonator. In total, there were 7 tunneling resonances. The full widths at half maximum of these dips were found to decrease with increasing momentum wave vector transfer (Q) and this correlated to the neutron lifetime in the nanostructured isotopic nickel based thin film Fabry-Perot resonator. / Physics / M. Sc. (Physics)
|
164 |
Contribution à l'étude de solutions non destructives pour la détection et la localisation de défauts électriques dans les structures électroniques 3D / Contribution to the study of non-destructive solutions for the detection and the localization of electrical defects in 3 D electronic structureCourjault, Nicolas 17 June 2016 (has links)
L'objectif de la thèse fut d'étudier plusieurs techniques d'analyse de défaillance (Microscopie magnétique, Thermographie à détection synchrone, Tomographie à Rayons X, Réflectométrie Temporelle) sur leur propriété de localisation de défaut électrique (Court-circuit, circuit ouvert, ouvert résistif, etc.) sur des systèmes et composants électroniques 3D. Des possibilités d'évolution de ces techniques sont suggérées afin de permettre d'assurer la localisation des défauts dans ces nouveaux composants électroniques. Ceci passe notamment par la mise en place d'analyses magnétiques sur des échantillons inclinés ainsi que par l'introduction d'une imagerie de phase, et d'amplitude magnétique. Ce travail a également permis de proposer le couplage d'informations obtenues par microscopie magnétique et tomographique à rayons X dont l'ensemble serait piloté par simulation magnétique 3D. / The thesis purpose was to explore several failure analysis techniques (Magnetic microscopy, Lock-in Thermography, X-rays Tomography, Time Domain Reflectometry) on their capabilities to localize the electrical defect (Short circuit, open circuit, resistive open, etc.) on 3D electronic component and system. Assessment possibilities of these techniques are suggested in order to ensure the defect localization in these new components. In particular, implementations of magnetic analysis in tilted sample as well as introduction of phase and amplitude magnetic images have been realized. This work also proposes to couple information obtain from magnetic microscopy to X-rays Tomography where the all system would be driven by 3D magnetic simulation
|
165 |
Desenvolvimento de uma sonda TDR helicoidal para uso em conjunto com o ensaio CPT / Developing a coil TDR probe to use together with the CPT testKaterin Guerrero Doria 21 August 2015 (has links)
A reflectometria no domínio do tempo permite estimar o teor de umidade de um meio através da sua correlação com a constante dielétrica. Uma sonda helicoidal TDR, que pode ser cravada em conjunto outros ensaios de penetração in situ para a estimativa do teor de umidade em diversas profundidades, tem aplicação interessante para a investigação geotécnica do subsolo. No presente trabalho, uma sonda TDR foi adaptada e utilizada em conjunto ao ensaio CPT para caracterização de um perfil de solo arenoso não saturado que ocorre na região de Bauru (SP). A calibração dessa sonda foi feita em laboratório especificamente para esse solo. As equações de calibração que mostraram os melhores resultados foram definidas correlacionando a constante dielétrica, condutividade elétrica aparente e a massa específica seca com o teor de umidade. Com o intuito de melhorar a acurácia na determinação do teor de umidade em campo e eliminar possíveis interferências no registro da onda eletromagnética, foram efetuadas modificações em algumas características do projeto original dessa sonda. Tais modificações consistiram em separar os eletrodos condutores e as partes metálicas da sonda, e eliminar o cabo coaxial de extensão, conectando a sonda diretamente a um cabo coaxial de 12 m de comprimento. Tais mudanças levaram a uma melhoria significativa na determinação do perfil de teor de umidade do local estudado. Os valores de teor de umidade de campo determinados usando o TDR ao longo de 8 m de profundidade foram comparados com os valores de referência obtidos de amostras deformadas retiradas com trado mecânico. O erro médio na estimativa do perfil de teor de umidade gravimétrico utilizando a sonda TDR helicoidal foi de 1.61%, na última campanha de ensaios realizados. Os resultados dessa pesquisa indicam que esta ferramenta é adequada para estimar do perfil de teor de umidade para uso em conjunto com o ensaio CPT. / The time domain reflectometry allows estimating the moisture content of a medium by means of its correlation with the dielectric constant. A coil TDR probe, which can be driven into the ground together with others in situ penetration tests, can be used to estimate the moisture content at different depths. It is an interesting approach for geotechnical site characterization. In this work, a coil TDR probe was adapted and used in combination with the CPT test for the site characterization of an unsaturated sandy soil profile which occurs in the region of Bauru (SP). The probe calibration was performed in laboratory specifically for that soil. The calibration equation, which presented the best results, were defined correlating the dielectric constant, electrical conductivity and dry density with the moisture content. In order to improve the accuracy for determining the water content in the field and to eliminate possible interference on the electromagnetic wave registration, modifications were made in some characteristics of the original design of this probe. Such modifications consisted in separating the conductive electrodes from the metal parts of the probe, and eliminating the coaxial extension cable, connecting the probe directly to a coaxial cable 12 m long. Such changes have led to a significant improvement in the determination of the moisture content profile of the studied site. The moisture content values determined in situ by using the TDR along 8 m depth were compared with reference values obtained from disturbed soil samples collected using mechanical augers. The root mean square error of the gravimetric water content profile using the TDR coil probe was 1.61% in the last test campaign. The results of this research indicate that this tool is suitable to estimate the gravimetric moisture content together with the CPT test.
|
166 |
Estimativa da retenção de água no solo a partir do uso de equipamentos não convencionais, redes neurais artificiais e funções de pedotransferência / Water retention soil estimate using nonconventional equipment, artificial neural networks and pedotransfer functionsAntonio Angelotti Netto 06 September 2007 (has links)
O desenvolvimento econômico e o aumento da produtividade agrícola intensificaram o uso de produtos químicos nas lavouras. Quando se pretende quantificar o impacto ambiental de tal uso é necessário empregar modelos que descrevam o fluxo de água e solutos na região não saturada do solo. Para esse fim, um dos parâmetros mais eficazes é conhecer a retenção de água no solo. O objetivo deste trabalho foi desenvolver funções de pedotransferência (FPTs) que estimassem a partir de análise em redes neurais artificiais (RNAs) a retenção de água nos solos da microbacia hidrográfica do ribeirão Canchim, município de São Carlos, SP. Os atributos físicos, textura (argila, silte e areia), densidade e resistência à penetração dos solos: LVAd, LVe, LVdf e NVef, manejados com e sem cobertura vegetal e sob mata foram determinados com equipamentos não convencionais na Embrapa Instrumentação Agropecuária em São Carlos, SP. Esses parâmetros foram utilizados como variáveis de entrada nas duas redes neurais artificiais. Foram obtidas, ainda, as curvas de retenção de água no solo por meio da câmara de pressão de Richards e da tomografia computadorizada, além da porosidade total e da condutividade hidráulica não saturada. O analisador granulométrico de solos e o penetrômetro associado a TDR possibilitaram a obtenção de um grande número de dados. Os atributos físicos dos solos apresentaram grande variabilidade em função da constituição granulométrica e manejos adotados. As RNAs foram eficientes no desenvolvimento de FPTs capazes de estimar a retenção de água com base em propriedades básicas de solo obtidas em grande número. / Economic development and increasing agricultural productivity have intensified the use of chemical products in farming. The quantification environmental impact of these products requires the use of models that describe the flow of water and solutes in the unsaturated region of the soil. For this purpose, one of the most effective parameters belong to the water retention curve of the soil. The purpose of this work was to develop pedotransfer functions (PTFs) to estimate the retention of water by soils of the hydrographic microbasin of the Canchim river, in the municipality of São Carlos, state of São Paulo, Brazil, based on artificial neural networks (ANNs). The physical attributes, granulometry (clay, silt and sand), density and resistance to penetration of LVAd, LVe, LVdf and NVef soils, managed with and without vegetal cover and under forest, were determined using nonconventional equipment at Embrapa Instrumentação Agropecuária in São Carlos, SP. These parameters were used as input variables for two artificial neural networks. The soils\' water retention curves were also obtained using a Richards pressure chamber and computed tomography, as well as their total porosity and unsaturated hydraulic conductivity. A soil granulometric analyzer and a penetrometer allied to TDR provided a large number of data. The soils\' physical attributes displayed a wide variability as a function of their granulometric constitution and adopted managements. The ANNs were effective in developing PTFs able to estimate the water retention based on the large number of basic soil properties.
|
167 |
Aplicação da reflectometria no domínio do tempo (TDR) na estimativa da condutividade elétrica da solução do solo e de concentrações de nitrato, potássio e cloreto em coluna de solo não saturado / Applying Time domain reflectometry (TDR) on estimating electrical conductivity and nitrate, potassium and chloride concentrations under unsaturated soil columns conditionsIsaac de Matos Ponciano 17 January 2012 (has links)
Devido à importância do monitoramento da composição iônica da solução do solo, no que diz respeito ao meio ambiente e ao manejo da fertirrigação, associada às limitações práticas dos métodos tradicionais de sua determinação é crescente a procura por um método confiável que possibilite o monitoramento desta composição em tempo real e em curtos intervalos de tempo. Neste sentido a TDR tem sido uma alternativa viável. O presente trabalho objetivou, pelo uso da TDR, avaliar o desempenho de sete modelos na determinação da CEw; relacioná-los com a concentração dos íons potássio nitrato e cloreto avaliando os modelos em determinar a concentração dos íons; e por fim monitorar e determinar a concentração destes íons na água lixiviada em coluna de solo não saturado. O trabalho foi divido em dois experimentos, no primeiro os modelos foram calibrados em colunas de solo sendo formado por 24 tratamentos composto por 4 faixas de umidade volumétrica e 6 concentrações da solução de KCl. Para cada coluna de solo era realizada uma leitura com a TDR ( e CEa) e a CEw na solução do solo era determinada por condutivímetro de mesa, nesta solução foram determinadas as concentrações de potássio e cloreto. No segundo experimento o mesmo procedimento foi realizado, entretanto, foi aplicado KNO3 e determinados potássio e nitrato. Desta forma, foi possível calibrar os modelos para a estimativa da CEw, e para determinação das concentrações dos íons potássio, nitrato e cloreto. Os modelos foram avaliados pelos coeficientes de determinação (R²) e exatidão (d), pela estimativa do erro padrão (EEP) e, ainda, foram classificados de acordo com o índice c, produto dos dois coeficientes citados. Os resultados mostram que os modelos de Rhoads et al. (1976) e Vogeler et al. (1996) se ajustam melhor para solos com características texturais argilosas sendo classificados como Ótimos métodos para a determinação da CEw, tanto pela aplicação de KCl como pela aplicação de KNO3 via água de irrigação. Na estimativa da CEw no solo arenoso os modelos de Munõz-Carpena et al. (2005), Mualen e Friedman (1991), Vogeler et al. (1996) e Rhoads et al. (1976) apresentam melhores ajustes na determinação da CEw, sendo classificados com Muito bom. Na determinação do potássio pelos modelos avaliados o melhor ajuste se dá pela associação da relação K-CEw do tipo potência aplicada para solos argilosos e linear para solos arenosos, apresentando classificação de: Ótimo e Muito bom, respectivamente. Para o cloreto e o nitrato o melhor ajuste se dá pela relação de CEw-Cl e CEw-NO do tipo linear, apresentando classificação de Muito Bom e Ótimo respectivamente. A TDR é uma técnica confiável no monitoramento da concentração dos íons potássio e cloreto lixiviados no perfil do solo. / There is a growing demand for a reliable method applied to monitoring ionic composition of soil solution in real-time and short time intervals, due the importance to environmental sustainability and fertigation management and limitations of traditional methods for determination. Time domain reflectometry (TDR) is often considered a viable alternative to traditional methods. Consequently, this research looks for using TDR evaluate the performance of seven mathematical models for determining electrical conductivity (CEw) by comparing simulated and measured concentrations of potassium, nitrate and chloride, and to monitor and determine the concentration of these ions in water leached from unsaturated soil columns. The research was carried out under two experiments conditions. In the first experiment the models were calibrated with input data from 24 soil columns consisting of four soils with six different KCl concentrations. For each soil column CEw was determined by both TDR ( and CEa readings) and the CEw of soil solution was determined by direct measurements of potassium and chloride concentrations. In the second experiment the procedure was the same, but with KCl being replaced with KNO3. This was possible to calibrate the models to estimate the CEw, and to determine potassium, nitrate and chloride ions concentrations. The models were ranked using the c-index, the coefficient of determination (R²) and estimated standard error (ESE). The results showed were Rhoads et al. (1976) and Vogel et al. (1996) classified as \"Great\" for the CEw determination associated with the application of both KCl and KNO3 to irrigation water in clay soils. For estimating CEw in sandy soils, the models Muñoz-Carpena et al. (2005), Mualen and Friedman (1991), Vogel et al. (1996) and Rhoads et al. (1976) were classified as \"Very Good.\" The relationship between CEw and potassium concentration was best represented by a power function in clay soils, and a linear function in sandy soils, with index of \"Great\" and \"Very Good\", respectively. For chloride and nitrate, the best fits were obtained by representing the CEw-Cl and CEw-NO3 relationships with linear functions, which were classified as Very Good and Good, respectively. TDR proved to be a reliable technique for monitoring the concentration of potassium and chloride ions leached in soil profiles.
|
168 |
[en] INTERROGATION SYSTEM FOR MULTIPLE BRAGG GRATING SENSORS USING TIME DOMAIN REFLECTOMETRY AND FIXED FILTERS / [pt] SISTEMA DE INTERROGAÇÃO DE MÚLTIPLOS SENSORES A REDE DE BRAGG UTILIZANDO REFLECTOMETRIA NO DOMÍNIO DO TEMPO E FILTROS FIXOSCARLA CARVALHO KATO 28 February 2005 (has links)
[pt] Este trabalho apresenta um sistema de interrogação de
sensores a rede de Bragg em fibras ópticas, baseado em
reflectometria no domínio do tempo e filtros fixos a rede
de Bragg. Utilizando uma fonte de luz pulsada, a posição
espectral do sensor é relacionada à razão da intensidade
dos pulsos, tornando a detecção independente de variações
de intensidade. São abordados aspectos teóricos e
experimentais referentes aos princípios de funcionamento
desta técnica. Uma vez que a filtragem é feita com redes de
Bragg, apenas um circuito de fotodetecção é utilizado e um
número reduzido de acopladores/circuladores ópticos é
necessário, o sistema possibilita reduzir consideravelmente
o custo para a interrogação de um conjunto de sensores. A
utilização de apenas um circuito de fotodetecção apresenta
a vantagem de manter as mesmas características para todos
os pulsos, minimizando influências externas neste circuito
como, por exemplo, variações da temperatura ambiente. Foi
montada uma bancada de testes para a interrogação de seis
sensores. Comparações entre os resultados experimentais e
simulados mostram boa concordância. Extrapolações indicam
que seria possível interrogar sensores com uma variação
espectral de 2 nanômetros, com incertezas menores que 10
picometros, o que é adequado para sensores de temperatura.
Análises de interferência entre dois canais adjacentes
mostram pouca influência entre eles e são apresentadas
opções para diminuir essa interferência. / [en] This work presents a system for the interrogation of fiber-
optic Bragg grating sensors based on time domain
reflectometry and Bragg grating fixed filters. Using a
pulsed light source, the spectral position of the sensor is
related to the ratio of two pulses intensities, making
detection independent of intensity variations. Theoretical
and experimental aspects regarding the working principles
of this technique are discussed. Since filtering is
accomplished with Bragg grating so that only one
photodetection circuit is used and a reduced number of
optic couplers/circulators are needed, the system provides a
considerable reduction in the cost of interrogation for a
set of sensors. Using only one photodetection circuit also
has the advantage of maintaining the same characteristics
for all pulses, thus minimizing external influences in this
circuit, such as variations in the environment temperature.
A test stand was assembled for the interrogation of six
sensors. Comparisons between experimental and simulated
results show a good agreement. Extrapolations indicate that
it would be possible to interrogate sensors with a spectral
variation of 2 nanometers, with uncertainties lower than 10
pm, which is adequate for temperature sensors. Cross talk
analyses between two adjacent channels show small influence
between them, and approaches to reduce this interference
are presented.
|
169 |
Simulace monitoringu optické trasy / Simulation of optical route monitoringMlejnek, Zbyněk January 2010 (has links)
Monitoring optical line for a long term monitoring and evaluating both transfer quality and running reliability of optical line links' physical layer (optical cable routes) fiber optical transfer systems. Monitoring indicates any kind of security erosion of transmission medium incited by either "natural" climatic and mechanical environmental effects, indeliberated cable violation (building operation) or by intended intervention into transfer path.
|
170 |
Etude des états fondamentaux dans des systèmes supraconducteurs désordonnés de dimension 2 / Study of accessible ground states in two-dimensional disordered superconductorsHumbert, Vincent 16 June 2016 (has links)
Un matériau 3D, initialement supraconducteur, peut avoir différents états fondamentaux dépendamment de son degré de désordre : supraconducteur, métallique ou isolant. A dimension réduite (2D), la localisation d’Anderson interdit théoriquement tout état métallique. La modification du désordre induit alors une Transition directe Supraconducteur-Isolant (TSI). La présence de fortes interactions électroniques, non prises en compte dans les théories conventionnelles, pourrait cependant remettre en cause ce paradigme et laisser émerger des états métalliques 2D, complexifiant l’image généralement admise de la TSI. Ainsi, des travaux récents ont révélé la présence de deux phases métalliques distinctes dans les films minces de a-NbxSi1-x, s’intercalant entre les états supraconducteur et isolant.Durant cette thèse, nous avons étudié les propriétés de transport électronique à basse fréquence et à très basse température (T<1K) de films minces de NbxSi1-x amorphes afin de caractériser l’évolution de l’état fondamental en fonction du désordre. Celui-ci a été modifié dans nos films en jouant sur la température de recuit, l’épaisseur et la composition. Nous nous sommes alors attardés sur la destruction de ces états métalliques vers un état isolant. L’analyse des lois de conduction dans le régime isolant nous a permis de quantifier l’évolution de ses propriétés – notamment des énergies caractéristiques – en fonction du désordre. Nous avons alors pu conclure que la phase isolante pouvait être essentiellement décrite par un modèle fermionique. A moindre désordre, dans la phase métallique 2D adjacente à l’isolant, nous avons mis en évidence des signes précurseurs de l’état isolant qui évoluent continument jusqu’à et à travers la Transition Métal 2D-Isolant. Nous proposons une interprétation de l’ensemble de nos résultats impliquant deux canaux parallèles dont l’importance relative est déterminée par le désordre : l’un est fermionique, l’autre gouverné par des fluctuations supraconductrices qui persistent même lorsque la cohérence macroscopique a disparu. L’état métallique est alors dominé par ces dernières, alors que, dans l’isolant, la localisation des excitations fermioniques l’emporte.Une seconde partie de la thèse s’est concentrée sur le développement expérimental d’un dispositif de calibration large bande dédié à l’étude de films minces en réflectométrie haute fréquence (GHz) à basses températures (T<4K). Ce dispositif a pour but, lors d’une unique mise à froid, de mesurer successivement la réflexion de références connues ainsi que de l’échantillon. La calibration obtenue permet ainsi de s’affranchir de l’environnement micro-onde et d’obtenir la valeur absolue de l’impédance complexe de ces films. Les résultats obtenus sur des films minces supraconducteurs de Vanadium, comparés aux théories de la supraconductivité, permettent une première validation du dispositif et de son principe de fonctionnement en vue d’une utilisation sur des systèmes plus complexes, tels que les films minces proches de la TSI. / An initially superconducting 3D material can have different ground states, depending on its disorder : superconducting, metallic or insulating. At lower dimensionality, Anderson localization theoretically forbids any metallic state. A change in disorder then induces a direct Superconductor-to-Insulator Transition (SIT). The presence of strong Coulomb interactions, which are not taken into account in conventional theories, may disrupt this paradigm and enable the emergence of 2D metallic phases, thus complicating the generally admitted picture for the SIT. Indeed, recent work has revealed the existence of two distinct metallic phases in a-NbxSi1-x thin films, in between the superconducting and insulating states.During this work, we have studied the low frequency transport properties of amorphous NbxSi1-x films at low temperatures (T<1K), in order to characterize the evolution of their ground state with disorder. In our films, disorder has been tuned by varying the heat treatment temperature, the thickness or the composition. We have then focused on the destruction of these metallic states, giving rise to an insulating state. Through the analysis of conduction laws in the insulating regime, we have quantified the evolution of its properties – in particular its characteristic energies – as disorder is varied. We could then conclude that the insulating phase can essentially be accounted for by a fermionic model. At lower disorder level, in the 2D metallic phase neighboring the insulator, we have evidenced precursor signs of the insulating state which continuously evolve until and through the 2D Metal-to-Insulator Transition. We offer an interpretation of all our results implying the existence of two parallel channels which relative importance is determined by the sample disorder level : one is fermionic, the other governed by superconducting fluctuations which persist even when the macroscopic phase coherence is lost. The metallic state is then dominated by the latter, whereas, in the insulator, fermionic excitations prevail.In a second part, we report on the experimental development of a calibration device for the broadband reflectometry measurement of thin films at microwave frequencies (GHz) and low temperatures (T<4K). This apparatus aims at measuring, during a single cool down, the reflection of known references as well as of the sample. The obtained calibration enables to obtain the absolute value of the films complex impedance, independently of the microwave environment. The results obtained on superconducting Vanadium films, compared with theories of superconductivity, enabled a first validation of the setup and of its working principle. This calibration device is therefore operational to measure more complex systems, such as thin films in the vicinity of the SIT.
|
Page generated in 0.2594 seconds