131 |
Avaliação dos ensaios de microtração, push-out e pull-out: resistência de união entre pino de fibra e dentina radicular, análise de elementos finitos e microscopia confocal / Evaluation of microtensile, push-out and pull-out bond strength tests in the adhesion of fiber posts to intraradicular dentin. Finite element analysis and confocal microscopyCarina Strano Castellan 28 June 2007 (has links)
O objetivo deste estudo foi comparar os ensaios de microtração (MI), ?push-out? (PS), ?push-out? modificado (PSM) e ?pull-out? (PL) na habilidade de mensurar a resistência de união (RU) entre pino de fibra e dentina radicular. Para tanto, além dos resultados de cada ensaio mecânico foram analisados fatores como: sensibilidade quanto às diferentes regiões radiculares, quantidade de falhas prematuras (FP), coeficiente de variação (CV), padrão de fratura (PF) pela microscopia confocal de varredura e distribuição das tensões pela análise de elementos finitos (AEF). Foram utilizados 40 dentes anteriores superiores endodonticamente tratados, divididos em quatro grupos de acordo com o tipo de ensaio realizado. Para os ensaios de PS e MI foi feita a cimentação do pino e posteriormente os cortes para a obtenção dos corpos-de-prova (cps). Para os outros ensaios (PSM e PL), a cimentação antecedeu aos cortes tanto das fatias de dentina como dos pinos. O sistema adesivo Scotbond Multi Uso Plus e o cimento Variolink II foram usados para a cimentação do pino de fibra de vidro FRC Postec Plus em todos os casos. Os cps do ensaio de PS foram obtidos pelos cortes seriados da raiz em fatias de 1±0,1mm, para os cps do ensaio de MI estas fatias sofreram ainda a confecção de entalhes laterais diametralmente opostos, que proporcionando um formato final de ampulheta. Para os testes de PL e PSM foram feitos cortes de fatias de dentina de 1±0,1mm e o pino foi dividido em três partes iguais para, então, cada fatia de uma região ser cimentada com o pino correspondente. Os cps do ensaio de PSM tinham 1mm de pino sobressalente para cima e para baixo da fatia de dentina, enquanto que os cps do PL o pino sobressalente estava apenas para cima da dentina. Todos os cps foram submetidos aos testes de RU, à velocidade de 0,5mm/min em máquina de ensaios universais. O PF foi avaliado em um aumento de cem vezes e foi feita uma distribuição de freqüência. Já a AEF obteve modelos tridimensionais de todos os ensaios, e estes foram analisados quanto à tensão de Von Mises. Para os resultados dos testes mecânicos foram feitas análises de variância de cada ensaio variando o fator região, com ou sem as FP, e análise comparando todos os ensaios. O teste Tukey foi feito quando necessário e as FP foram submetidas ao teste estatístico de Fisher. A inclusão ou não destas falhas mostra alteração dos resultados no ensaio de MI, uma vez que possui um maior número delas neste ensaio. O ensaio de PL mostrou as maiores médias de RU, seguido pelo ensaio de PSM, e ambos também tiveram o PF com maior quantidade de fraturas adesivas. O ensaio de PS conseguiu apontar diferença estatística entre as três regiões, mas mostrou a maior freqüência de falhas coesivas, e maior CV. O menor CV foi encontrado para o PSM que também mostrou uma adequada distribuição das tensões. A MI apresentou concentração de tensões nas bordas dos entalhes. Concluiu-se que o tipo de ensaio influencia diretamente nos resultados obtidos. / The aim of this study was to compare microtensile (MI), \"push-out\" (PS), modified \"push-out\" (PSM) and \"pull-out\" (PL) tests in the ability to accurately measure the bond strength of fiber posts luted inside root canals, at different root dentin levels, cervical, middle and apical. The evaluated parameters were: amount of premature failure (PF), coefficient of variation (CV), failure patterns (FP) and the stress distribution by finite elements analysis (FEA). Forty human intact single-rooted and endodontically treated teeth were divided into four groups according to the type test used. For PS and MI specimens, first the post was luted and then the cuts were done, for PSM and PL, first was done the cuts and then fiber post?s pices were luted. Scotbond Multi Use Plus adhesive system and Variolink II cement had been used for luting FRC Postec Plus glass fiber post, in all cases. PS samples were disc shaped of 1±0,1mm. Bond strength between post and dentin was measured in the root slice and the force applied on the center of the specimen. For the Mi test hourglass-shaped samples were obtained by trimming the proximal surfaces of each slice using a diamond bur until it touched the post. For PL and PSM tests cuts of 1±0,1mm of dentine slices were made and the fiber was divided into three parts, and then each slice were luted with a fiber post?s piece. Specimens for PSM had 1mm of post up and down the dentin slice and for PL all of the post was up the dentine slice. All specimens were submitted to a bond strength test at 0.5 mm/minute crosshead speed in a universal testing machine. For FP, each sample was examined under confocal microscopy at 100 times and a frequency distribution was made. For the AEF, three-dimensional models of each tests had been made and analyzed by Von Mises stress. Bond strength data were analyzed by ANOVA and when necessary was used Tukey?s test. For PF data the Fisher test was made. The inclusion of PF, only shows variation on MI, since these test showed the greater number of them. PL provided higher values of bond strength for root dentin and fiber post, followed by PSM. Both of them had also FP with greater amount of adhesive failures. The PS test was able to point statistically differences between root regions, but it showed the highest frequency of cohesive failure, and greater CV. Minor CV was found for the PSM that also showed adequate stress distribution. The MI showed concentration of tensions in the edges of the trimming area. One concluded that the type of test influences directly in the results obtained.
|
132 |
Comparação dos ensaios de resistência adesiva por torção e por cisalhamento com fio / A comparison between torsion and wire-loop shear bond strength testsTathy Aparecida Xavier 24 March 2010 (has links)
Objetivo: verificar, através de análise por elementos finitos e de uma etapa experimental, se o ensaio de torção, como ensaio de resistência de interfaces adesivas, seria capaz de levar os espécimes à ruptura sob tensões de cisalhamento e se ele seria vantajoso em relação ao ensaio de cisalhamento. Material e Método: para a análise de tensões pelo método dos elementos finitos, os modelos tridimensionais dos dois ensaios foram constituídos por cilindro de compósito, uma camada de adesivo e um cilindro de dentina com maior diâmetro. Os espécimes foram simulados nos tamanhos convencional e micro, numa proporção de 5:1, exceto pela camada de adesivo, de espessura constante. Foram simulados dois módulos de elasticidade do cilindro de compósito (híbrido e baixa viscosidade) e, para os modelos de cisalhamento, variaram as distâncias entre o local de carregamento e a interface adesiva. Foram analisados os valores das tensões máxima principal e cisalhamento máximo e a proporção entre elas ao longo da interface dentina/adesivo; a direção dos vetores de tensão máxima principal; e o local dos picos de tensão. Na etapa experimental, foram construídos cilindros de compósito (híbrido e de baixa viscosidade) nos tamanhos convencional e micro, aderidos a uma superfície de dentina bovina por meio de três sistemas adesivos. O esforço de cisalhamento foi aplicado com fio ortodôntico a uma distância da interface adesiva baseada na literatura e, para os ensaios de torção e microtorção, foram desenvolvidos dispositivos específicos para a aplicação do torque. Os resultados de tensão de ruptura foram submetidos à análise de variância e teste de Tukey. Todas as superfícies de fratura foram analisadas por meio de microscopia eletrônica de varredura. As frequências das fraturas adesivas e coesivas foram submetidas ao teste exato de Fisher e relacionadas aos valores de tensão de ruptura experimentais, bem como suas características foram relacionadas às tensões observadas pelo método dos elementos finitos. Os parâmetros experimentais de comparação entre os ensaios foram: poder de detecção de diferenças significantes entre os sistemas adesivos; constância da classificação relativa dos mesmos ao alterar as configurações dos ensaios e frequências dos tipos de fratura. Resultados: ambos os ensaios apresentaram um estado complexo de tensões com distribuição nãouniforme. Não foi notada menor sensibilidade dos resultados do ensaio de torção às mudanças das configurações do teste, nem uma maior capacidade para detectar diferenças significantes entre os adesivos do que o ensaio de cisalhamento. O ensaio de torção apresentou maior dificuldade de execução prática e maiores frequências de fraturas coesivas, porém, estas ocorreram mais no cilindro de compósito, enquanto no cisalhamento, ocorreram mais na dentina. Não houve certeza sobre o tipo de tensão que tenha levado à fratura nos dois tipos de ensaio. Conclusões: embora não se tenha certeza se o ensaio de torção leva à ruptura sob tensões de cisalhamento e tenham sido notadas desvantagens práticas de execução do ensaio, este apresenta uma característica que sugere novos estudos: ocorrência de fraturas coesivas principalmente no cilindro de compósito, o que poderia, talvez, ser resolvido com o reforço do material do cilindro. / Objective: verify, by finite element analysis (FEA) and laboratorial tests, if the torsion bond strength test is able to lead adhesive interface to fracture under shear stress and if it would be more advantageous than wire-loop shear test. Material and method: for stress analysis by finite element method, the 3D models of both tests consisted of a resin composite cylinder, an adhesive layer and a dentin cylinder with a larger diameter. The specimens were simulated with both conventional and micro sizes, in a 5:1 ratio, except for the adhesive layer, kept in a constant thickness. Two values of elastic modulus were simulated for the composite cylinder (hybrid and flowable). For the shear models, different distances were simulated between the load point and the adhesive interface. The values of maximum principal and maximum shear stresses and the ratio between both types were analyzed along the adhesive interface, as well as the maximum principal vectors direction and the local of stress peaks. For the laboratorial tests, cylinders of hybrid and flowable resin composite, in both micro and conventional sizes, were adhered onto dentin surfaces by means of 3 adhesive systems. The shear load was applied with a metallic wire-loop at distances from the interface based on literature and, for the torsion test, the torque was applied by specific apparatus developed for that. The values of bond strength were submitted to analysis of variance and Tukeys test. Fracture surfaces were analyzed by scan electron microscopy. The frequencies of fracture types were compared by Fishers test and its relationship with bond strength values were verified, as well as the relationship between fracture features and stresses results obtained by FEA. The experimental parameters for comparison between both tests were: ability for detecting significant differences among the 3 adhesives, change of adhesives ranking while varying the test configuration and frequency of fracture types. Results: both tests showed non-uniform stress distribution. It was not noticed a lower sensibility of torsion test results to changes of the test configurations, nor a major ability for detecting significant differences among the adhesive systems than showed the shear test. The torsion test showed to be more difficult to execute and exhibited a higher frequency of cohesive fracture, however, that occurred most of the time in the composite cylinder, while it occurred mainly in dentin in shear test. There was no certainty about the kind of stress that lead to specimen fracture in both tests. Conclusions: although there was no certainty about the kind of stress that lead to specimen fracture and the major difficulty of execution of torsion test, this test exhibited a feature that suggests future studies: the occurrence of cohesive fracture mainly in the composite cylinder, which could be solved, maybe, by reinforcing the cylinder material.
|
133 |
Influência do hidróxido de cálcio na resistência de união de cimentos endodônticos resinosos à dentina radicular / Influence of calcium hydroxide in the bond strength of root canal sealers to dentin: push-out testingCeci Nunes Carvalho 01 July 2010 (has links)
Avaliou-se a influência do uso do hidróxido de cálcio como medicação intracanal na resistência de união de obturações endodônticas à dentina radicular quando realizadas com o cimento AH Plus ou Epiphany. Raízes palatinas de primeiros molares superiores humanos foram preparadas com sistema rotatório EndoSequence, e divididas em 4 grupos: G1 fatias preenchidas com AH Plus; G2 - fatias preenchidas com Epiphany; G3 - dentes que receberam medicação intracanal com hidróxido de cálcio por 14 dias e posterior preenchimento das fatias com AH Plus; G4 - dentes que receberam medicação intracanal com hidróxido de cálcio por 14 dias e posterior preenchimento das fatias com Epiphany. Para o teste de pushout as raízes foram fixadas, cortadas e delas obtidas secções seriadas das regiões cervical, média e apical. Após a manobra de preenchimento das fatias, essas permaneceram armazenados por 7 dias em câmara a vácuo a 37º C sob condições de umidade ambiental. Decorrido esse período, os dentes foram preparados para o ensaio mecânico. Os corpos-de-prova foram adaptados a um suporte fixado à base da máquina de ensaios mecânicos universal, onde aplicou-se uma carga à velocidade de 0,5 mm/min no sentido ápico-cervical até o completo deslocamento do material obturador. Após a realização dos ensaios, foi feita análise do padrão de fraturas dos corpos de prova utilizando a microscopia eletrônica de varredura. A análise de variância revelou diferença estatisticamente significante entre os grupos (p<0,05). O teste de Tukey identificou que a resistência de união obtida pelos grupos Epiphany e Epiphany + hidróxido de cálcio foi estatisticamente menor do que a dos grupos AH Plus e AH Plus + hidróxido de cálcio; e, a comparação entre grupos mostrou que o grupo AH Plus + hidróxido de cálcio mostrou-se estatisticamente superior ao grupo AH Plus, portanto o hidróxido de cálcio influencia positivamente apenas na adesão do cimento AH Plus. / We evaluated the influence of calcium hydroxide as an intracanal dressing in the bond strength of root canal filling to the root dentin when performed with AH Plus sealer or Epiphany. Palatal roots of maxillary first molars were prepared with rotary system EndoSequence and divided into 4 groups: G1 - slices filled with AH-Plus G2 - slices filled with Epiphany, G3 - teeth that received root canal dressing with calcium hydroxide for 14 days and then filling out the slices with AH-Plus; G4 - teeth that received root canal dressing with calcium hydroxide for 14 days and then filling out the slices with Epiphany. To test push-out the roots were fixed, cut them and obtained serial sections of cervical, middle and apical. After the maneuvers fills the slices, they remain stored for 7 days in a vacuum chamber at 37°C under conditions of environmental humidity. After this period the teeth were prepared for mechanical testing. The samples were adapted to a bracket attached to the base of the testing machine universal where we apply a load at a speed of 0.5 mm/min towards apicocervical to the complete displacement of the filling material. After the testing, analysis was made of the pattern of fractures of the specimens using scanning electron microscopy. Analysis of variance revealed a statistically significant difference between groups (p < 0,05). The Tukey test indicated that the bond strength obtained by the groups Epiphany and Epiphany + Calcium hydroxide was lower than that of groups AH Plus and AH-Plus + Calcium hydroxide; and, the comparison between groups showed that group AH-Plus + Calcium hydroxide was statistically higher than the AH-Plus group, so the Calcium hydroxide has a positive effect only in the adhesion of AH-Plus sealer.
|
134 |
Efeito de diferentes tratamentos ácidos na rugosidade superficial e na resistência de união da cerâmica de dissilicato de lítio / Effect of different acid treatments in the surface roughness and the bond strength of lithium disilicate ceramicSudré, João Paulo da Silva 06 May 2015 (has links)
Submitted by isabela.moljf@hotmail.com (isabela.moljf@hotmail.com) on 2016-08-04T17:39:56Z
No. of bitstreams: 1
joaopaulodasilvasudre.pdf: 2148062 bytes, checksum: c73715b2cb00a515bba21c95536911d3 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2016-08-05T11:49:24Z (GMT) No. of bitstreams: 1
joaopaulodasilvasudre.pdf: 2148062 bytes, checksum: c73715b2cb00a515bba21c95536911d3 (MD5) / Made available in DSpace on 2016-08-05T11:49:24Z (GMT). No. of bitstreams: 1
joaopaulodasilvasudre.pdf: 2148062 bytes, checksum: c73715b2cb00a515bba21c95536911d3 (MD5)
Previous issue date: 2015-05-06 / O objetivo deste estudo foi avaliar o efeito de diferentes tratamentos ácidos, variação da concentração e do tempo de exposição aos ácidos, hidrofluorídrico (HF) e fosfórico (H3PO4), sobre a rugosidade superficial e resistência de união de uma cerâmica vítrea reforçada por dissilicato de lítio cimentada com um cimento resinoso autoadesivo. Cem pastilhas da cerâmica IPS e.max Press® medindo 2 x 7 mm foram divididas em dez grupos de acordo com o tratamento de superfície (n=10): G1, controle, ou seja, sem tratamento; G2, G3 e G4 condicionamento com HF 5% por 20, 40 e 60 segundos, respectivamente; G5, G6 e G7, condicionamento com HF 10% por 20, 40 e 60 segundos, respectivamente; G8, G9 e G10 condicionamento com HF a 10% por 20,40 e 60 segundos respectivamente e, posteriormente, condicionamento com ácido fosfórico 37% por 5 segundos. A análise da rugosidade superficial foi feita em microscópio ótico confocal. As pastilhas representativas de cada grupo foram selecionadas e metalizadas para análise da morfologia superficial em microscopia eletrônica de varredura e em microscópio de força atômica. Para a análise de resistência de união ao microcisalhamento, sobre as superfícies devidamente tratadas, foi aplicado o silano RelyX Ceramic Primer® e aguardou-se 1 minuto para que se realizasse a cimentação. Foram cimentados três cilindros em cada pastilha com o cimento resinoso RelyXTM U200, e fotopolimerizados por 60 segundos cada. Os corpos de prova foram armazenados em água deionizada a 37°C por 24 horas (n=30). Terminado esse tempo, os corpos de prova foram submetidos ao teste de microcisalhamento em uma máquina de ensaios universal Emic DL 2000® com velocidade de 1 mm/minuto até que ocorresse a fratura. Os valores médios de ambos os testes foram submetidos à análise estatística ANOVA dois fatores e as médias comparadas pelo teste de Tukey com 5% de significância. Todas as superfícies fraturadas foram levadas ao estereomicroscópio com aumento de 50 vezes para verificar o padrão de falha ocorrido e alguns corpos de prova após a fratura, foram aleatoriamente escolhidos para representar cada tipo de falha, foram metalizados e levados ao microscópio eletrônico de varredura para caracterização da superfície. A maior rugosidade superficial foi obtida pelo grupo G6 (2,05±0,107) sendo superior estatisticamente aos demais. Já a menor rugosidade foi obtida pelo grupo controle G1 (0,567±0,057) e inferior estatisticamente aos demais. Os grupos G7 (1,785±0,037); G3 (1,608±0,03); G10 (1,551±0,046); G9 (1,449±0,047); G5 (1,443±0,06); G4 (1,422±0,103); G8 (1,339±0,036) e G2 (1,283±0,059) apresentaram valores intermediários de rugosidade. Dentre estes grupos, o G3 (22.75±1.97MPa) foi o que apresentou a maior média de resistência da união com falhas do tipo mista. Por outro lado, o G1 (5.25±1.29MPa) apresentou o menor valor médio de resistência da união com predominância de falhas adesivas. Assim, conclui-se que a concentração do ácido e o tempo influenciaram na rugosidade superficial, sendo maior para o
condicionamento com ácido HF a 10%. Para a resistência da união, o tempo de condicionamento e a interação deste com a concentração dos ácidos influenciou de forma significativa; sendo que o ácido HF de menor concentração, 5% por 40 segundos, foi o que apresentou maiores valores. / The objective of this study was to evaluate the effect of different acid treatments, the concentration variation and the time of exposure to hydrofluoric (HF) and phosphoric acids (H3PO4) on the surface roughness and bond strength of a glass-ceramic reinforced by cement lithium disilicate with a self-adhesive resin cement. One hundred tablets of the IPS e.max Press® ceramic measuring 2 x 7 mm were divided into ten groups according to the surface treatment (n = 10): G1, control, or untreated; G2, G3 and G4 etching with 5% hydrofluoric acid for 20, 40 and 60 seconds, respectively; G5, G6 and G7 etching with 10% hydrofluoric acid for 20, 40 and 60 seconds, respectively; G8, G9 and G10 etching with 10% hydrofluoric acid for 20, 40 and 60 seconds respectively, and subsequently etched with phosphoric acid at 37% for 5 seconds. Analysis of surface roughness was performed confocal optical microscope. Representative tablets of each group were selected and metallized for analysis of surface morphology in scanning electron microscopy and atomic force microscope. For the analysis of bond strength to microshear, on properly treated surfaces, the silane RelyX Ceramic Primer® was applied and waited up to 1 minute to the holding of the cementing. Three-cylinder in each tablet were cemented with resin cement RelyXTM U200, and light cured for 60 seconds. The specimens were stored in deionized water at 37C for 24 hours (n = 30). After this time, the specimens were submitted to microshear test in a universal testing machine Emic DL 2000® with speed of 1 mm/min until the fracture. The average values of both tests were submitted to ANOVA two factors and the means compared by Tukey test at 5% significance level. All fractured surfaces were taken to the stereomicroscope with 50X enlargement to verify the pattern of failure occurred and some specimens with significant fractures of each type of failure were metallized and taken to the scanning electron microscope for surface characterization. The increased surface roughness was obtained by the G6 group (2.05 ± 0.107 N) and statistically superior. Already the slightest roughness was obtained by G1 control group (0.567 ± 0.057) and statistically lower to others. The G7 (1.785 ± 0.037); G3 (1.608 ± 0.03); G10 (1.551 ± 0.046); G9 (1.449 ± 0.047); G5 (1.443 ± 0.06); G4 (1.422 ± 0.103); G8 (1.339 ± 0.036) and G2 (1.283 ± 0.059) showed intermediate roughness values. Among these groups, the G3 (22.75 ± 1.97 N) was presented the highest mean bond strength with failures of mixed type. Moreover, G1 (5.25 ± 1.29 N) had the lowest average value of the bond strength with a predominance of adhesive failures. Thus, it is concluded that the acid concentration and time influence the surface roughness, being greater for etching with 10% hydrofluoric acid. For the bond strength, the conditioning time and the interaction of this with the concentration of the acid had a significant influence; being that the hydrofluoric acid of lower concentration, 5% for 40 seconds, showed the highest values.
|
135 |
A influência da água na composição de primers autocondicionantes experimentais / Influence of the water concentration in an experimental self-etching primer on the bond strength to dentinLima, Giana da Silveira 21 December 2007 (has links)
Made available in DSpace on 2014-08-20T14:30:07Z (GMT). No. of bitstreams: 1
Dissertacao_giana_da_silveira_lima.pdf: 1493174 bytes, checksum: 68e4c67538ad95eba022c0a0e790d4b8 (MD5)
Previous issue date: 2007-12-21 / To investigate the influence of different water concentrations in self-etching primers solvents on microtensile bond strength (μTBS) of an experimental adhesive system. Five experimental self-etching primers with 0, 5, 10, 20 and 40 water concentration (wt %) in solvent, were synthesized. Clearfil SE Bond (CSEB) was used as commercial adhesive. Sixty bovine incisive were randomize separated in six groups (n=20). Vestibular enamel was removed to expose the superficial coronal dentin, this surface was polished wet to create a standardized smear layer. After rinsing, water was removed, leaving the surface visibly dried. The dentin surfaces were etched with primer and air-dried, after coating adhesive resin was applied and photo-activated, following the composite resin restoration was accomplished. After storage for 24 hours, the specimens were sectioned with a refrigerated diamond saw at low-speed. Microtensile bond strength were measured and data were analyzed by one-way ANOVA/Tukey s test (α=0.05). Analysis of variance showed that primer composition was a significant factor for bond strength. There was not difference on bond strength of the primers with water concentration: 40% (53.9 ± 12.7 MPa), 20% (51.1 ± 11.5 MPa) and 10% (47.5 ± 11.4 MPa) and CSEB (52.44 ± 13.27 MPa). The group with 5% (38.6 ± 12.9 MPa) and 0% (31.5 ± 7.5 MPa), present similar bond strength amongst themselves but statistically smaller that the other groups. The water concentration, present in the primer solvent, exercise significant influence on the bond strength of this experimental self-etching adhesive system / Este estudo avaliou a influência de diferentes concentrações de água no solvente de um primer autocondicionante de um sistema adesivo dentinário experimental. Foram formulados cinco primers experimentais com diferentes concentrações, 0; 5; 10; 20; 40%, de água em massa e Clearfil SE Bond (CSEB)
foi utilizado como referência comercial. Foram utilizados 60 incisivos bovinos, distribuídos aleatoriamente entre 6 grupos (n= 20). Na face vestibular dos dentes foi realizado desgaste com lixas até a exposição de dentina com lixa d água 600.
O primer foi aplicado sobre a dentina previamente seca com papel absorvente, sendo aplicado jato de ar e em seguida o adesivo foi aplicado e foto-ativado com aparelho fotopolimerizador LED SDI Radii®. A restauração foi confeccionada utilizando 2 incrementos, fotoativados de acordo com as recomendações do fabricante. Após armazenagem por 24 horas em água destilada à 37°C, os dentes foram seccionados em cortadeira de precisão e a resistência de união mensurada, através de ensaio de microtração em uma máquina de ensaios mecânicos. Análise de Variância segundo um critério e teste complementar de Tukey foram utilizados na análise estatística (α=5%). Não houve diferença na resistência de união de P40 (53,9 ±12,7 MPa) P20 (51,1 ±11,5 MPa) e P10 (47,5 ±11,4 MPa) e CB (52,44 ±13,27 MPa). Os grupos P5 (38,6 ±12,9 MPa) e P0 (31.5 ±7.5 MPa) não apresentaram diferença estatística entre si, mas seus valores de adesão dentinária foram menores que os demais grupos (p<0,05). A resistência de união dentinária do sistema adesivo experimental testado sofre influência da concentração de água presente no solvente do primer autocondicionante
|
136 |
Influência da composição do primer sobre a resistência de união à microtração em sistema adesivo autocondicionante experimental / Influence of experimental self-etching primers composition on microtensile bond strengthMadruga, Francine Cardozo 21 December 2006 (has links)
Made available in DSpace on 2014-08-20T14:30:10Z (GMT). No. of bitstreams: 1
Dissertacao_Francine_Cardozo_Madruga.pdf: 401845 bytes, checksum: 455f72341e671454f219f56884bf2224 (MD5)
Previous issue date: 2006-12-21 / The aim of this study was to investigate the influence of different functional monomer concentrations/HEMA in self-etching primers solvents on microtensile bond strength
(μTBS) of an experimental adhesive system. Seventy bonive incisors were allocated in seven groups (n=20). Six experimental self-etching primers were synthesized with
different concentratios of acidic monomer (MPF); 0, 15, 30, 50, 70 and 100 (wt %)(Groups EMa0, EMa15, EMa30, EMa50, EMa70, EMa100 respectively). Adhesive system Clearfil SE Bond (CSEB, Kuraray) was used as control. Coating adhesive resin AP-50 was prepared Seventy bovine incisors were randomized and allocate in seven groups. Vestibular enamel was grounded to expose the superficial coronal dentin, witch that was polished wet to create a standardized smear layer with 600 grit silicon paper. After rinsing, water was removed with a piece of absorbent paper, leaving the surface visibly
dried. The prepared dentin surfaces were etched with primer and air-dried, after coating adhesive resin was applied and light activated with LED SDI Radii® (1400mW/cm2). The
composite resin was inserted in two increments and were ligth activated for 20 s each. After storage for 24 hours, the specimens were sectioned with a refrigerated diamond
saw at low-speed. To investigate immediate microtensile bond strength (μTBS) statistical analysis were performed (one-way ANOVA plus Tukey s post-hoc test, α=0.05). Fractographic analysis were performed using optical microscopy to describe
failure patterns. The group EMa50 showed statistically higher (p<0.05) microtensile bond strength (55.1MPa) than others experimental groups but was similar with control (50.7MPa). Due total premature failure groups EMa0 and EMa100 were exclude form statistics. Groups EMa15, EMa30 and EMa70 were similar but different that control. Was possible conclude that concentration of acidic monomer/HEMA affects microtensile bond strength of self-etching adhesive systems. Primer composition of 50%MPF-20%HEMA- 30% water showed satisfactory microtensile bond strength as a self-etching adhesive system. / O objetivo deste estudo foi avaliar a influência de diferentes composições variando as concentrações de monômero ácido/HEMA em primer autocondicionante de sistema adesivo dentinário experimental. Foram utilizados 70 incisivos bovinos, distribuídos aleatoriamente entre 7 grupos (n=20). Foram formulados seis primers experimentais com concentrações de 0; 15; 30; 50; 70%; e 100% de monômero ácido (MPF) em massa (Grupos EMa0, EMa15, EMa30, EMa50, EMa70, EMa100 respectivamente). O sistema adesivo Clearfil SE Bond (CSEB, Kuraray) foi utilizado como controle. Na face vestibular dos dentes foi realizado desgaste até a exposição de dentina com lixa d água granulação até 600. O primer foi aplicado vigorosamente sobre a dentina previamente seca com papel absorvente, sendo aplicado jato de ar e em seguida o adesivo foi aplicado e foto-ativado com aparelho fotopolimerizador LED SDI Radii® (1400mW/cm2). A restauração foi confeccionada utilizando 2 incrementos de 2 mm de compósito,fotoativados de acordo com as recomendações do fabricante. Após armazenagem por 24 horas em água destilada a 37°C, os dentes foram seccionados em cortadeira de precisão e a resistência de união (MPa) mensurada através do ensaio de microtração em uma máquina de ensaios mecânicos. As amostras fraturadas do ensaio de microtração foram avaliadas por microscopia óptica e classificadas quanto ao modo de fratura. Análise de Variância segundo um critério e teste complementar de Tukey foram utilizados para detectar diferenças entre médias (α=5%). O grupo EMa50 apresentou o maior valor (p<0,05) de resistência de união à microtração em dentina (55,1MPa) entre os primers experimentais, sendo esse valor semelhante ao encontrado no controle comercial (50,7MPa). Os grupos EMa0 e EMa100 demostraram-se inviáveis por apresentarem totalidade de falhas prematuras e foram excluídos da estatística, os grupos EMa15, EMa30e EMa70 foram semelhantes e estatisticamente inferiores ao controle. Baseado na metodologia do presente estudo foi possível concluir que variações de concentração de monômero ácido/HEMA na composição de sistemas adesivos autocondicionantes afetam os valores de resistência de união à dentina sendo que a composição 50%MPF-20%HEMA-30%Água demonstrou valores iniciais satisfatórios de resistência de união para o desenvolvimento de um sistema adesivo experimental autocondicionante.
|
137 |
Efeito do hidróxido de cálcio na formulação de cimentos resinosos autoadesivos / Effect of calcium hydroxide in the formulation of adhesive resin cementsMadruga, Francine Cardozo 18 May 2012 (has links)
Made available in DSpace on 2014-08-20T14:30:11Z (GMT). No. of bitstreams: 1
Tese_Francine_Cardozo_ Madruga.pdf: 29010459 bytes, checksum: 5e3b51088eb6a2939cfc07531186e6a7 (MD5)
Previous issue date: 2012-05-18 / In this study the effect of the addition of calcium hydroxide Ca(OH)2 on the pHneutralization and physico-chemical properties of experimental self-adhesive resin cements was investigated. The cements were formulated as two pastes: Paste A, containing UDMA, Bis-GMA, TEGDMA, HEMA, GDMA-P and glass particles; Paste B, composed of UDMA, HEMA, water, photoinitiators and glass particles. The formulation variable tested was concentration of Ca(OH)2, added to paste B at mass fractions of 0% (control), 0.25%, 0.5%, 1%, 2%, and 4%. Equal volumes of pastes A and B were mixed for the analyses, which started by immersion of cement specimens in distilled water and follow up of the pH of the eluate for 24 h. The additional analyses consisted in measurement of degree of C=C conversion by infrared spectroscopy, film thickness, flexural strength, elastic modulus and work-of-fracturei n 3-point bending mode, Knoop hardness, depth of cure, water sorption and solubility after immersion in water for 7 days, and dentin bond strength by shear testing. Statistical comparisons between groups were carried out at a 5% significance level. All Ca(OH)2 concentrations above 0.25% caused pH increase of the eluate at 24 h, although the only concentrations of the compound leading to pH-neutralization were 2% and 4%. Compared with the control cement, the addition of 4% Ca(OH)2 decreased the flexural strength, flexural modulus, work-of-fracture, degree of C=C conversion, and dentin bond strength. In contrast, the physico-chemical properties of the material with 2% Ca(OH)2 were similar to the control material, except for a discreet reduction in mechanical strength and the lower film thickness of the material containing Ca(OH)2. Hardness, depth of cure, and water sorption were not affected by incorporation of Ca(OH)2. The material with 4% Ca(OH)2 had lower solubility and film thickness than the other cements. In conclusion, judicious incorporation of Ca(OH)2 might lead no pH-neutralization of self-adhesive resin cements without negatively interfering with other physico-chemical properties of the material. / Neste estudo investigou-se o efeito da adição de hidróxido de cálcio Ca(OH)2 na neutralização do pH e propriedades físico-químicas de cimentos resinosos autoadesivos experimentais. Os cimentos foram formulados em duas pastas: Pasta A, contendo UDMA, Bis-GMA, TEGDMA, HEMA, GDMA-P e partículas de vidro; Pasta B: composta por UDMA, HEMA, água, fotoiniciadores e partículas de vidro. A variável de formulação testada foi a concentração de Ca(OH)2, adicionado à pasta B nas frações em massa de 0% (controle), 0,25%, 0,5%, 1%, 2% e 4%. Volumes iguais de pasta A e B foram misturados para as análises, que iniciaram pela imersão em água destilada de espécimes de cimento e acompanhamento do pH do eluato por 24 h. As demais análises consistiram em mensuração do grau de conversão de C=C por meio de espectroscopia no infravermelho, espessura de película, resistência à flexão, módulo de elasticidade e trabalho de fratura por meio de teste de flexão por 3 pontos, dureza Knoop, profundidade de polimerização, sorção e solubilidade após imersão em água por 7 dias, e resistência de união à dentina por meio de teste de cisalhamento. Comparações estatísticas estre os grupos foram realizadas em nível de significância de 5%. Todas as concentrações de Ca(OH)2 acima de 0,25% ocasionaram aumento do pH do eluato em 24 h, porém as únicas concentrações do composto que levaram à neutralização do pH foram 2% e 4%. Comparado com o cimento controle, a adição de 4% de Ca(OH)2 reduziu a resistência à flexão, módulo de flexão, trabalho de fratura, grau de conversão de C=C e resistência de união à dentina. Por outro lado, as propriedades físicoquímicas do material contendo 2% de Ca(OH)2 foram similar ao material controle,
exceto por discreta redução de propriedades mecânicas e pela menor espessura de película do material contendo Ca(OH)2. Dureza, profundidade de polimerização e sorção de água não foram afetadas pela incorporação de Ca(OH)2. O material com
4% de Ca(OH)2 apresentou menor solubilidade e espessura de película que os demais cimentos. Em conclusão, a incorporação criteriosa de Ca(OH)2 pode levar à neutralização do pH de cimentos resinosos autoadesivos sem interferir de forma
negativa em outras propriedades físico-químicas dos materiais.
|
138 |
Desenvolvimento de sistemas adesivos empregando monômeros surfactantes como alternativa ao hidróxietil metacrilato (HEMA) / Development of adhesive systems employing surfactant monomers as substitute to hydroxyethyl methacrylate (HEMA)Zanchi, Cesar Henrique 07 May 2010 (has links)
Made available in DSpace on 2014-08-20T14:30:11Z (GMT). No. of bitstreams: 1
Tese_Cesar_Henrique_Zanchi.pdf: 1068579 bytes, checksum: 8e2ef86f128f91b16a71c1a2e41952f6 (MD5)
Previous issue date: 2010-05-07 / This study evaluated the influence of surfactant dimethacrylates (SD) on the resin-to-dentin immediate and long term microtensile bond strength (μTBS) and characterized the interfacial micromorphology of hybrid layer of the experimental HEMA-free self-etching systems. Five experimental HEMA-free two step self-etching systems containing different surfactant dimetacrylates (SD) (Bis-EMA 10, Bis-EMA 30, PEG 400, PEG 1000 and PEG 400 UDMA) and a HEMA-containing systems (control) were formulated. Sixty bovine incisors were allocated into six groups according
each experimental adhesive system used. The teeth had the superficial coronal dentins exposed and were restored and sectioned to obtain sticks randomly allocated into 3 storage periods: 24h, 6 and 12 months. Thereafter the specimens were subjected to the μTBS test. Immediate μTBS data were analyzed by One-way ANOVA and Tukey s test. Long term μTBS data were analyzed by Kruskall-Wallis and Dunn test (α = 0.05). Analysis of the adhesive-dentin interfaces were performed through scanning electron microscopy. Between the HEMA-free groups, the adhesive system formulated with PEG 400 UDMA produced the highest μTBS and was similar to HEMA-containing group. Specimens of the 24 hours of storage were statistically higher for all groups tested when compared those after 6 and 12 months storage. None difference was found between 6 months and 12 months storage for each group. All the adhesives systems presented similar partially demineralized hybrid layer (1.5-3.0 μm thickness) with well formed resin tags. All SD present reasonable μTBS, being the PEG 400 UDMA a promising monomer to be considered as HEMA substitute in adhesive systems compositions. / Este estudo avaliou a influência de dimetacrilatos surfactantes (DS) na resistência de união à dentina por microtração (RU), imediata e após armazenagem, além de caracterizar a micromorfologia da camada híbrida de sistemas adesivos experimentais autocondicionantes livres de HEMA. Foram formulados cinco sistemas adesivos autocondicionantes de dois passos livres de HEMA contendo diferentes DS (Bis-EMA 10, Bis-EMA 30, PEG 400, PEG 1000 and PEG 400 UDMA) e um sistema contendo HEMA, empregado como controle. Foi realizada a exposição da dentina superficial de sessenta incisivos bovinos posteriormente alocados em seis grupos experimentais de acordo com o sistema adesivo empregado. Os dentes foram restaurados e seccionados para obter espécimes (palitos) posteriormente divididos em três períodos de armazenagem: 24h, 6 e 12 meses. Após, os espécimes foram sujeitos ao teste de RU. Resultados de RU imediata foram analisados por ANOVA 1-fator e teste complementar de Tukey. Resultados de RU após envelhecimento foram analisados por Kruskall-Wallis e teste de Dunn (α = 0.05). Analises das interfaces de união dente-restauração foram realizadas através de microscopia eletrônica de varredura. Entre os grupos livres de HEMA, o sistema adesivo formulado com PEG 400 UDMA produziu maior RU e foi estatisticamente similar ao grupo controle contendo HEMA. Os espécimes testados após 24 horas de armazenamento apresentaram RU estatisticamente maior para todos os grupos quando comparados os espécimes testados após 6 e 12 meses de armazenagem. Não foram observadas diferenças significativas entre os grupos testados após 6 e 12 meses. Todos os sistemas adesivos apresentaram camada hibrida parcialmente desmineralizada (1.5-3 μm de
espessura) com formação de prolongamentos resinosos. Em geral os sistemas adesivos demonstraram valores de RU satisfatórios, sendo o PEG 400 UDMA um monômero promissor para o desenvolvimento de sistemas adesivos livres de HEMA.
|
139 |
Análise do desempenho de condicionadores experimentais no tratamento de ligas metálicas / Evaluation of experimental conditioners in the metal alloys treatmentAzevedo, Eduardo Costa de 19 December 2007 (has links)
Made available in DSpace on 2014-08-20T14:30:18Z (GMT). No. of bitstreams: 1
Dissertacao_Eduardo_Costa_de_Azevedo.pdf: 706035 bytes, checksum: 2849c6cbcccaf4c4e34fbdb0b6e8e482 (MD5)
Previous issue date: 2007-12-19 / The aim of this study was to investigate the performance of three experimental surface conditioners on metal alloys of different chemical composition, through microshear tests and failure analysis. Three metal alloys (NiCr, AgPd, AgAu) were melted in disc-shaped specimens (3mm in thickness x 10mm in diameter) and their surfaces were polished with aluminum oxide abrasive papers (400-, 600- and 1200-grit). The groups were treated with one of the experimental surface conditioners, and a commercial material (Alloy Primer Kuraray) was used as a control. The bonding agent of the Adper Scotchbond system (3M) was applied, and cylindrical specimens were made with a resin cement (Rely X ARC 3M), with an adhesion area of
1.13mm2. The bonding agent and the cement were light-activated for 40s (LED SDI Radii® - 1400mW/cm2). The micro-shear test was conducted at a cross-head speed of 0.5mm/min. Bond strength values were calculated in MPa (N/mm2) and submitted to ANOVA and Tukey s post-hoc test (p<0.05). Fractographic analyzes were performed under optical microscopy (40X) and classified as adhesive, mixed or
cohesive. The experimental surface conditioners did not present a satisfactory performance factor due to the means variation in the metal alloys used in the study. A predominance of adhesive failures was detected. In conclusion, the experimental surface conditioners presented a significant adhesion to all metal alloys. However, these materials need modifications to obtain values more approximate to the
commercial material / O objetivo deste estudo foi avaliar o desempenho de três condicionadores experimentais em ligas metálicas de diferentes composições químicas, através de testes de microcisalhamento e análise de fratura. Três ligas metálicas (NiCr, AgPd, AgAu) foram fundidas em forma de disco (3x10 mm) e suas superfícies foram preparadas com lixas d água (400, 600 e 1200#). Todos os grupos receberam um tratamento superficial com quatro condicionadores, sendo três experimentais e um
comercial (Alloy Primer- Kuraray Medical Corporation, Kurashiki, Okayama, Japão) que serviu de controle. Logo após o condicionamento, foi aplicado o adesivo do sistema Adper Scotchbond (3M Dental Products Division, Saint Paul, MN, EUA) e sobre este foram confeccionados os corpos de prova com um cimento resinoso de ativação dupla Rely X ARC (3M Dental Products Division, Saint Paul, MN, EUA) com uma área de adesão de 1,13 mm2. O adesivo e o cimento resinoso utilizados foram fotoativados com aparelho LED SDI Radii® (1400mW/cm2) por 40 segundos. Os ensaios mecânicos foram executados com velocidade de 0,5 milímetros por minuto. Os valores de resistência adesiva foram registrados em MPa (N/mm2 = Newton/milímetro2) e submetidos a Análise de Variância e teste complementar de Tukey para detectar diferença entre as médias (p < 0,05). A análise da superfície de fratura foi observada através de microscopia óptica com um aumento de 40X sendo classificada como falha adesiva, mista ou coesiva. Os condicionadores experimentais não apresentaram um fator de desempenho satisfatório devido à
variação das médias nos substratos metálicos utilizados. Houve predominância de falha do tipo adesiva. Baseado na metodologia foi possível concluir que os condicionadores experimentais apresentaram resistência de união significante nos grupos avaliados, porém necessitam de modificações para alcançarem valores mais aproximados ao material comercial
|
140 |
AVALIAÇÃO DA RESISTÊNCIA DE UNIÃO DE DIFERENTES SISTEMAS DE CIMENTAÇÃO ADESIVA AO ESMALTE E A DENTINA / BOND STRENGTH EVALUATION OF DIFFERENT SYSTEMS FOR ADHESIVE CEMENTATION TO ENAMEL AND DENTINMutti, Isabele do Nascimento 21 January 2010 (has links)
Objective: The aim of this study was to evaluate the bond strength to enamel and dentin of a self-adhesive resin cement applied with different cementation strategies,
using a conventional resin cement as control. Material and Methods: Sixty healthy human molars were selected and allocated into 6 groups (n=10) according to cementation system and dental substrate: ARCe (Adper Single Bond 2 + RelyX ARC in enamel), U100e (RelyX U100 in enamel), a+U100e (Phosphoric acid + RelyX U100 in enamel), ARCd (Adper Single Bond 2 + RelyX ARC in dentin), U100d
(RelyX U100 in dentin), a+U100d (Phosphoric acid + RelyX U100 in dentin). Composite resin blocs (Filtek Z250) were confectioned with dimensions of 4mm x 6mm x 4mm to enamel and 7mm x 7mm x 4mm to dentin, and immediately cemented
on the surfaces according to each group. Each resin-tooth assembly was stored in 370C distilled water for 24 hours and longitudinally sectioned into two axis producing
specimens (sps) with area of approximately 1mm2. The sps were submitted to microtensile test at 1 mm/min and failures were observed with stereomicroscopic magnifying glass with 32x magnification. Data were submitted to Analysis of Variance and Tukey s test (5%). Results: Means (MPa) were: ARCe: 50.5; U100e: 24.5; a+U100e: 53.5; ARCd: 36.0; U100d: 26.7; a+U100d: 25.9. No statistical
difference was found between groups that used acid etching in enamel, thus presenting values higher than U100 without previous acid etching. In dentin, values were higher (p<0.05) for ARCd compared to U100d and a+U100d groups, which presented similar results. Conclusions: Previous acid etching prior to cementation in enamel enhanced bonding of self-adhesive cement to dental structure.In dentin this acid etching did not influenced bond strength values of this cement. / Objetivo: O objetivo desse trabalho foi avaliar a resistência de união ao esmalte e à dentina, de um cimento resinoso auto-adesivo aplicado com diferentes estratégias de cimentação, utilizando um cimento resinoso convencional como controle.
Material e Métodos: Sessenta molares humanos hígidos foram divididos em 6 grupos (n=10) de acordo com o sistema de cimentação e substrato dentário: ARCe (Adper Single Bond 2 + RelyX ARC em esmalte), U100e (RelyX U100 em esmalte),
a+U100e (Ácido fosfórico + RelyX U100 em esmalte), ARCd (Adper Single Bond 2 + RelyX ARC em dentina), U100d (RelyX U100 em dentina), a+U100d (Ácido fosfórico + RelyX U100 em dentina). Blocos de resina composta (Filtek Z250) foram
confeccionados com dimensões de 4mm x 6mm x 4mm para esmalte e 7mm x 7mm x 4mm para dentina, sendo imediatamente cimentados nas superfícies de acordo
com cada grupo. Os conjuntos resina-dente foram armazenados em água destilada à 370C por 24 horas e seccionados longitudinalmente em dois eixos originando
corpos-de-prova (cps) com área de aproximadamente 1mm2. Os cps foram submetidos ao ensaio de microtração a 1 mm/min e as falhas foram observadas em lupa estereoscópica com aumento de 32x. Os dados foram submetidos à Análise de
Variância e Teste de Tukey (5%).
Resultados: As médias (MPa) foram: ARCe: 50,5; U100e: 24,5; a+U100e: 53,5; ARCd: 36,0; U100d: 26,7; a+U100d: 25,9. Não houve diferença estatística entre os grupos que utilizaram condicionamento ácido em esmalte, sendo superiores ao U100 sem condicionamento ácido prévio. Em dentina, os valores apresentaram-se maiores (p<0,05) no grupo ARCd que nos grupos U100d e a+U100d, sendo que esses últimos apresentaram resultados similares.
Conclusões: O condicionamento ácido prévio à cimentação em esmalte melhorou a união do cimento auto-adesivo à estrutura dentária e este mesmo condicionamento
em dentina, não alterou os valores de resistência de união desse cimento.
|