• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 113
  • 1
  • Tagged with
  • 115
  • 67
  • 65
  • 37
  • 23
  • 18
  • 15
  • 14
  • 13
  • 12
  • 12
  • 12
  • 11
  • 10
  • 10
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Geofísica aplicada no monitoramento de área de disposição de resíduos sólidos domiciliares

Moreira, César Augusto [UNESP] 24 April 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:32:17Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-04-24Bitstream added on 2014-06-13T20:43:11Z : No. of bitstreams: 1 moreira_ca_dr_rcla.pdf: 2315680 bytes, checksum: 0c4f65c2b2bcf53160a74f7b3683d14b (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Este trabalho realiza um monitoramento em uma área de disposição de resíduos sólidos, para análise do comportamento temporal dos materiais enterrados e verificação da hipótese de aplicação e uso dos métodos geofísicos em estudos que prevejam o término na geração de chorume em aterros. Foram medidos os parâmetros físicos: resistividade elétrica, cargabilidade e potencial elétrico natural, a partir dos métodos geofísicos de Eletrorresistividade, Polarização Induzida e Potencial Espontâneo, por meio da técnica de caminhamento elétrico e de sondagem elétrica vertical. Também foram realizadas medidas de pH, Eh, ensaios de peneiramento, análise granulométrica e permeabilidade hidráulica de campo. Foi investigado o Aterro Controlado Municipal de Cordeirópolis (SP), uma área de disposição de resíduos sólidos domiciliares em valas escavadas no solo, com datas de abertura e fechamento programadas. A aquisição de dados consistiu na seleção de valas anualmente fechadas entre 12/2001 e 12/2007, realização dos ensaios geofísicos e coleta de solo para medidas de pH e Eh. Houve um aumento do potencial espontâneo das valas recentes para as valas antigas, possivelmente associado à estabilidade geoquímica crescente ao longo do período de degradação dos resíduos orgânicos. Há uma correlação entre baixa resistividade e alta cargabilidade em áreas ricas em matéria orgânica, enquanto que áreas com escassez de matéria orgânica são caracterizadas por baixos valores de cargabilidade e de resistividade. Também há uma correlação entre anomalias de baixo potencial espontâneo e de alta cargabilidade. A variação relativa dos parâmetros para cada vala, associados ao tempo de residência dos materiais, permitiu relacioná-los às fases de degradação de matéria orgânica em aterros. A análise estatística dos valores indica ser necessário 8 anos para... / This work accomplishes a monitoring in solid waste landfill, for analysis of the temporary behavior of the buried materials and verification of the application hypothesis and use of the geophysical methods in studies that foresee the end in the leachate generation in landfill. They were measured the physical parameters: electric resistivity, chargeability and natural electric potential, starting from the geophysical methods of Electrical Resistivity, Induced Polarization and Spontaneous Potential, through the techniques of electric profiling and vertical electric sounding. Were also accomplished pH and Eh measures, sieving, granulates analysis and hydraulic permeability field. The Cordeirópolis Solids Waste Landfill was investigated, a disposition area of domiciliary residues in ditches dug in the soil, with opening and closing programmed dates. The data acquisition consisted in annually selection of ditches closed between 12/2001 and 12/2007, accomplishment of the geophysical survey and soil collection for pH and Eh measures. There was an increase of the spontaneous potential of the recent ditches for the old ditches, possibly associated to the geochemical stability growing along the period of degradation of the organic residues. There is a correlation between low resistivity and high chargeability in rich areas in organic matter, while areas with shortage of organic matter are characterized by low chargeability values and of low resistivity. There is also a correlation among anomalies of low spontaneous potential and high chargeability. The relative variation of the parameters for each ditch, associated to residence time of the materials, allowed relating them the phases of degradation of organic matter in landfills. The statistical analysis of the values indicates to be necessary 8 years for return to the natural resistivity values of the rock located to 10m of depth and 12 years... (Complete abstract click electronic access below)
52

Emprego do método da eletro-resistividade na caracterização da lixeira de Porto Velho - RO assentada em meio fraturado

Costa, Adeilton Fernandes da [UNESP] 08 July 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:32:18Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-07-08Bitstream added on 2014-06-13T19:02:48Z : No. of bitstreams: 1 costa_af_dr_rcla.pdf: 1751728 bytes, checksum: 47313b86159b0305db3753bcef660368 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Ensaios geofísicos de eletro-resistividade, através das técnicas da sondagem elétrica vertical e imageamento elétrico (configurações Schlumberger e dipolo-dipolo), foram executados na área da lixeira da cidade de Porto Velho, Estado de Rondônia, com o objetivo de identificar a contaminação do subsolo e das águas subterrâneas. A geologia sobre a qual está assentado o aterro de Porto Velho é constituída por sedimentos pleistoceno (argilo-arenosos com concreções lateríticas) assentados sobre rochas graníticas da Formação Santo Antônio. Os resultados mostraram que a aplicação dessas duas técnicas permite identificar locais de ocorrências dos resíduos, zonas de fraturas, diferentes litotipos do subsolo, fluxo das águas subsuperficiais e avaliar o impacto ambiental causado no meio ambiente. / Resistivity survey, with vertical electrical sounding and electrical imaging (Schlumberger and dipole-dipole configurations), were done at the waste disposal area, in city of Porto Velho, state of Rondônia, Brazil with the objective to identify the contamination of the subsoil and groundwater. The local geology is constituted by pleistocenic sediments (clay-sandy litology with lateritic concretionary) overlies granitic rocks of Santo Antônio Formation. The results showed that integrating this geophysical techniques can identify places of occurrences of waste, fractures zones, different lithotypes the subsoil, underground flow and evaluate the environmental impact caused by the waste disposal
53

Resistividade elétrica de cerâmicas de alumina a temperatura ambiente e a 600oC / Electrical resistivity of alumina at room temperature and 600oc

Kawasaki, Jorge Massato 10 March 1992 (has links)
Made available in DSpace on 2016-06-02T19:11:52Z (GMT). No. of bitstreams: 1 2544.pdf: 3680075 bytes, checksum: f791ed469797dc67db9cfe85de6c4148 (MD5) Previous issue date: 1992-03-10 / Alumina (Al2O3) ceramic specimens have been prepared via traditional ceramic process, namely, powder analyses, classification and conditioning, uniaxial cold pressong and sintering. DC electrical resistivity measurements has been carried out at RT and 600oC. A tubular resistive furnace with an alumina sample chamber with platinum leads and electrodes was used. The main results show that the electrical resistivity of polycrystalline alumina increases with the decrease of the porosity, having as a limit the single crystal resistivity. Moreover, the electrical resistivity depends on the average grain size in the 4Wm 10 Wm range. For grain sizes smaller than 4 Wm the porosity is found to be higher than 0,1%. / Ceramicas de Al2O3 foram preparadas pelas tecnicas ceramicas convencionais: a) analise, classificacao e preparacao dos pos de partida, b) compactacao uniaxial em molde flutuante a frio e c) sinterizacao ao ar em forno resistivo. A microestrutura das amostras, com cobertura de fina camada de Au- Pd foi estudada por meio de microscopia eletronica de varredura. As medidas de resistividade eletrica foram feitas pela tecnica dc das duas pontas nas temperaturas ambiente e 600oC. Para estas medidas, foi montada uma camara porta-amostra com suportes e espacadores de alumina, eletrodos e terminais eletricos de platina. O principal objetivo do programa de pesquisa e a identificacao de valores de resistividade eletrica de alumina com diferentes teores de pureza e diferentes distribuicoes e tamanho medio de grao. Os principais resultados mostram que a resistividade eletrica em ceramicas policristalinas de alumina aumenta com a diminuicao da porosidade, existindo uma proporcionalidade entre o valor da resistividade eletrica e o tamanho medio de graos do intervalo compreendido entre 4 e 10 Wm.
54

Caracterização geofísica de contaminação por hidrocarbonetos em acidente ferroviário no município de Botucatu - SP / Geophysical characterization of hydrocarbon contamination in a railway accident in municipality of Botucatu (SP)

Cavallari, Fernanda [UNESP] 27 March 2017 (has links)
Submitted by Fernanda Cavallari null (fee.cavallari@gmail.com) on 2017-05-18T02:01:15Z No. of bitstreams: 1 cavallari_f_me_rcla.pdf: 4868463 bytes, checksum: f8aa337d6db1b37fa37f09ef94076c5f (MD5) / Approved for entry into archive by Luiz Galeffi (luizgaleffi@gmail.com) on 2017-05-19T12:47:13Z (GMT) No. of bitstreams: 1 cavallari_f_me_rcla.pdf: 4868463 bytes, checksum: f8aa337d6db1b37fa37f09ef94076c5f (MD5) / Made available in DSpace on 2017-05-19T12:47:13Z (GMT). No. of bitstreams: 1 cavallari_f_me_rcla.pdf: 4868463 bytes, checksum: f8aa337d6db1b37fa37f09ef94076c5f (MD5) Previous issue date: 2017-03-27 / O diagnóstico de áreas contaminadas é um procedimento obrigatório ao tratamento e remediação de solo e águas subterrâneas. Contaminantes complexos como hidrocarbonetos passam por transformações físicas e químicas ao longo do tempo de permanência no ambiente geológico, com alterações no grau de dissolução no sistema aquífero. Este trabalho descreve a aplicação de métodos geofísicos integrados com um histórico de dados químicos, numa área contaminada por hidrocarbonetos vazados num acidente ferroviário, em 2005, na zona rural do município de Botucatu (SP). Foram utilizados os métodos geofísicos Eletrorresistividade e Polarização Induzida, por meio de 5 linhas paralelas de tomografia elétrica em arranjo Schlumberger, programadas e posicionadas a partir da interpretação de um histórico de análises geoquímicas do solo e água subterrânea. Os dados de tomografia elétrica permitiram a geração de modelos de inversão 2D e modelos de visualização 3D. De forma geral, o histórico de análises geoquímicas, última atualização em 2007, indica claramente a redução de teores de contaminantes em solo e no aquífero. A análise integrada de dados indica o avançado estado de degradação dos hidrocarbonetos, reconhecido por elevados valores de alta cargabilidade em relação ao padrão natural da área, concomitantemente a zonas de média resistividade. As áreas contaminadas e monitoradas por análise químicas foram caracterizadas por alta cargabilidade e média resistividade, com indícios de neoformação pretérita de sulfetos e condições próximas as do ambiente geológico natural, ou seja, indícios de processo avançado de atenuação natural e quase desaparecimento dos contaminantes. / The diagnosis of contaminated areas is a mandatory procedure to treatment and remediation of soil and groundwater. Complex contaminants like hydrocarbons undergo physical and chemical changes along the dwell time in the geological environment, with changes in dissolution and spread in unsaturated and saturated soil aquifer system. This research describes the application of geophysical methods integrated with a history of chemical data in a contaminated area by leaked hydrocarborn in a railway accident, in 2005, at rural area in Botucatu (SP). The geophysical methods Electrical Resistivity and Induced Polarization were used by 5 parallel lines of electrical resistivity tomography in Schlumberger array, programmed and adjusted from a history of chemical analysis of groundwater. The electrical tomography data allowed the generation of 2D inversion models and visualization of 3D models. In general, the history of geochemical analysis, last updated in 2007, clearly indicates a reduction of contaminant levels in soil and in the aquifer. The data integrated analysis indicated the advanced state of degradation of hydrocarbons, recognized by high values of high chargeability in relation to the natural pattern of the area, concomitantly to areas of medium resistivity. The areas contaminated and monitored by chemical analysis were characterized by high chargeability and medium resistivity, with indications of past formation of sulfides and conditions close to the natural geological environment, that is, indications of advanced process of natural attenuation and near disappearance of the contaminants.
55

Caracterização de ocorrência de cobre por meio de levantamento estrutural e geofísico em faixa de dobramentos na região de Caçapava do Sul (RS) / Geoelectric prospection of copper occurrence in folding layers in the sul-riograndense shield (Brazil)

Santos, Shaiely Fernandes dos [UNESP] 23 June 2017 (has links)
Submitted by SHAIELY FERNANDES DOS SANTOS null (fer.shay@gmail.com) on 2017-07-04T16:04:57Z No. of bitstreams: 1 Dissertação Final_corrigida.pdf: 6609770 bytes, checksum: cf68b44bd226d8bbeb5bf8ce1f2066e6 (MD5) / Approved for entry into archive by Luiz Galeffi (luizgaleffi@gmail.com) on 2017-07-04T18:34:07Z (GMT) No. of bitstreams: 1 santos_sf_me_rcla.pdf: 6609770 bytes, checksum: cf68b44bd226d8bbeb5bf8ce1f2066e6 (MD5) / Made available in DSpace on 2017-07-04T18:34:07Z (GMT). No. of bitstreams: 1 santos_sf_me_rcla.pdf: 6609770 bytes, checksum: cf68b44bd226d8bbeb5bf8ce1f2066e6 (MD5) Previous issue date: 2017-06-23 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A ampla variedade de aplicações de cobre estimula a exploração de áreas mineralizadas. A prospecção de sulfetos por meio de métodos geofísicos, como a Eletrorresistividade e a Polarização Induzida (IP), são altamente promissores devido ao contraste de resistividade elétrica e cargabilidade, onde depósitos com sulfetos disseminados ou filoneanos são caracterizados por baixa resistividade e alta polarizabilidade. Esse trabalho realizou estudo de prospecção geofísica por meio de aquisição tomográfica em ocorrência mineral de cobre, na região de Caçapava do Sul (RS). Foram realizadas três linhas de aquisição por meio da técnica de tomografia elétrica em arranjos Dipolo-dipolo, Schlumberger e Wenner com 400 metros de comprimento e 5 metros de espaçamento entre eletrodos, dispostas de forma perpendicular à estruturação geral da área, representada com um grande sinclinal, de alta complexidade geológica e estrutural, em cuja crista foram reconhecidas galerias de pesquisa com carbonatos e sulfetos de cobre. Os resultados indicam que o arranjo dipolo-dipolo melhor realça e detalha as feições em regiões com estruturas inclinadas e fraturas. Os modelos de inversão 2D e modelamento 3D apresentam regiões centrais e laterais com alta resistividade e alta cargabilidade com indicativo de provável zona de stockwork com sulfetos alojados. Zonas periféricas com moderada resistividade e moderada cargabilidade inferem possíveis áreas com presença de argilização, zonas com alta cargabilidade e baixa resistividade são prováveis zonas de sulfetação e as possíveis zonas de silicificação com altos valores de resistividade e baixos de cargabilidade, observadas nas adjacências das prováveis zonas mineralizadas. / The wide variety of copper applications encourages the exploration of mineralized areas. Sulfide prospecting by means of geophysical methods, such as electrical resistivity and induced polarization (IP), are highly promising due to the contrast of electrical resistivity and chargeability, where deposits with disseminated sulfides or filoneans are characterized by low resistivity and high polarizability. This work carried out a study of geophysical prospecting by means of tomographic acquisition in mineral copper occurrence, in the region of Caçapava do Sul (RS). Three acquisition lines were performed by means of electrical tomography technique using a Dipole-dipole, Schlumberger and Wenner arrangements, with a length of 400 meters and a spacing of 5 meters between the electrodes, arranged in perpendicular layout to the general structure of the area, represented by a large synclinal, of high geological and structural complexity, where research galleries with carbonates and copper sulfides were recognized in the ridge. The results indicate that the dipole-dipole arrangement best highlights and details features in regions with sloped structures and fractures. The 2D inversion models and 3D modeling indicate central and lateral regions with high resistivity and high chargeability with indicative of probable stockwork zone with housed sulfides. Peripheral zones with moderate resistivity and moderate chargeability infer possible areas with presence of argilization, zones with high chargeability and low resistivity are likely to be zones of sulfation and possible silicification zones with high resistivity values and low chargeability values, observed in the vicinity of the probable mineralized zones.
56

Dimensionamento de sistemas de aterramento em linhas de transmiss?o para escoamento eficiente de correntes de surtos atmosf?ricos

D?lia, Ant?nio dos Santos 14 December 2012 (has links)
Made available in DSpace on 2014-12-17T14:56:12Z (GMT). No. of bitstreams: 1 AntonioSD_DISSERT.pdf: 1216426 bytes, checksum: 7fd76cc37669a46f507ab80033e1227e (MD5) Previous issue date: 2012-12-14 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior / This work presents in a simulated environment, to analyze the length of cable needed counterweight connected to ground rod, able to avoid the phenomenon of flashover return, back flashover, the insulator chains of transmission lines consisting of concrete structures when they are subjected to lightning standardized regarding certain resistivity values of some kinds of soil and geometric arrangements of disposal of grounding systems structures / Este trabalho apresenta, em ambiente simulado, a an?lise do comprimento necess?rio de cabo contrapeso interligado a haste de aterramento, capaz de evitar o fen?meno de descarga disruptiva de retorno, back flashover, nas cadeias de isoladores de Linhas de Transmiss?o constitu?das de estruturas de concreto, quando s?o submetidas a descargas atmosf?ricas padronizadas considerando determinados valores de resistividade de solo e alguns tipos de disposi??o de arranjos geom?tricos de sistemas de aterramento das estruturas
57

Propriedades de magneto-transporte no sistema BaFe2−xTMxAs2 / Magneto-transport properties of BaFe2−xTMxAs2 system

Peña Pacheco, Jully Paola January 2016 (has links)
Esta Tese consiste num estudo experimental de propriedades de transporte elétrico em amostras do sistema BaFe2−xTMxAs2 (Ba122), onde TM representa um metal de transição. Os elementos que foram utilizados como substituintes foram TM = Mn, Co, Cu e Ni. Estes compostos, genericamente denominados de ferro-pnictídeos, apresentam estado fundamental com ordenamento antiferromagnético do tipo onda de densidade de spin, ou supercondutor, ou ainda um estado de coexistência entre estes dois. Neste trabalho, as propriedades de maior interesse são a resistividade elétrica, a magnetorresistência e o efeito Hall. Aqui, essas propriedades são cuidadosamente estudadas com o objetivo de contribuir para o entendimento dos principais mecanismos de espalhamento eletrônico, na presença de campo magnético externo, nos compostos da família Ba122. Para isso, medidas sistemáticas das componentes longitudinal e transversal da resistividade elétrica em função da temperatura e do campo magnético foram realizadas em todas as amostras. A influência das substituições químicas e a desordem estrutural no transporte de carga também é investigada. Na análise dos resultados, ênfase é dada aos efeitos relacionados ao ordenamento magnético. A interpretação dos resultados experimentais obtidos toma por base efeitos de condução por duas bandas eletrônicas, uma do tipo elétron e outra do tipo lacuna, e contribuições devidas ao espalhamento dos portadores de carga por excitações de origem magnética. Mostra-se que tais termos são importantes para o entendimento do comportamento da magnetorresistência e do coeficiente de Hall com a temperatura e com o campo magnético na fase magneticamente ordenada dos sistemas estudados. / This Thesis reports on electric transport measurements in several single-crystal samples of the BaFe2−xTMxAs2 (Ba122) system, where TM is a transition metal. The elements used in substitution to the Fe atoms are TM = Mn, Co, Cu and Ni. When TM = Co or Ni, samples with different concentrations of the substituting element are investigated. Electrical resistivity, magnetoresistance and Hall effect experiments were carried out between 2 and 300 K, under magnetic field varying between 0 and 9 T. These properties are studied to shed light on the electronic scattering mechanisms relevant to these compounds. We are also interested in the role of the chemical substitutions and the effects of structural disorder in these properties. One important result of this Thesis is that the magnetoresistance is very small in the paramagnetic phase of the studied materiais, whereas its magnitude increases substantially in the magnetically ordered phase. Consistently, the Hall coefficient is also small in the paramagnetic state, and its magnitude becomes appreciable and strongly temperature dependent in the magnetically ordered phase. We observe that, for the same values of field and temperature, the magnetoresistance is higher in samples with higher magnetic transition temperatures. On the other hand, samples where a large fraction of the Fe atoms were substituted show a smaller magnetoresistance. This result is independent of the valence of the substituting atom and can also be observed in pure samples which show some structural disorder in the conducting layers. Results for a sample where 75 % of the Fe atoms are substituted by Cu atoms, which does not undergo a magnetic transition, show that, the magnetoresistance and the Hall coefficient remain small in the whole temperature interval investigated. This fact indicates that the characteristic behavior of these two properties in low temperatures is intrinsically related to the magnetic ordering. In order to explain the magnetoresistance and the Hall effect in the paramagnetic as well as in the magnetically ordered phase of the iron-pnictides of the Ba122 family, we suggest that, not only the multiple band character of the electronic structure is important, but contributions related to scattering by magnetic excitations should be properly considered. These contributions are in fact, the responsible for the overall behavior of the magnetoresistance and Hall effect inside the magnetically ordered phase of these compounds. In this aspect, the proposed interpretation for the magneto-transport properties of the Ba122 iron-pnictides contrasts with the description most commonly found in the literature, where effects coming from the Fermi surface morphology are supposed to play the dominant role.
58

Estudo experimental da resistividade elétrica em ligas de Heusler

Kunzler, Julio Vitor January 1980 (has links)
Medidas de resistividade elétrica foram realizadas nas ligas de Heusler cu 2Mn (Al 1 -xSnx), onde x =O; 0,05; 0,10 e 0,15, no intervalo de temperaturas de 4,2 a 800°K. Foram também efetua das medidas nas ligas de Heusler Ni 2MnX,. com X = In, Sn ou Sb, no intervalo de 4,2 a 300°K . As curvas experimentais mostram clar amente a importância do caráter fe rromagnetico nas re sistivi dades das ligas. Os resultados obtidos para as ligas de cobre, bem como para a liga Ni 2MnSn, estão em concórdância com uma interpretação em termos dos modelos de Bloch-Grüneisen e de desordem de spin, e falham quando tentamos obter evidên cias de espalhamento s-d para os elétrons de condução. Esse não é o caso para as ligas Ni 2Mnln e Ni 2MnSb, em que a presença de processo de espalhamento eletrônico interbanda (s-d), via fonon, foi detectada. Especialmente para as duas últimas ligas, são sugeridas experiências de calor especifico e de foto-emissividade eletrônica. / Electrical resistivity measurements have been performed on the Cu 2Mn (Al 1 -xsnx) Heusler alloys, where x =O, 0.05, 0.10 and 0.15, in the temperature range of 4.2 to 800 o K. Measurements have also been made on the Ni 2MnX Heusler alloys, with X = In, Sn or Sb, in the range of 4.2 to 300°K. The experimental curves clearly show the importance of the ferromagnetic character on the alloys resistivities. The results obtained for the copper allooys, as well as for the Ni 2MnSn alloy, are in ágreement with an interpretation in terms of Bloch-Grüneisen and spin-disorder models, and fail to provide evidences of s-d scattering for the conduction electrons. This is not the case for the Ni 2Mnln and Ni 2MnSb alloys, in which the presence of (s-d) interband electronic scattering process, via phonon, was detected. Specially for the two last alloys specific heat and electronic photo-emissivity experiments are suggested.
59

Estudo experimental da resistividade elétrica em ligas de Heusler

Kunzler, Julio Vitor January 1980 (has links)
Medidas de resistividade elétrica foram realizadas nas ligas de Heusler cu 2Mn (Al 1 -xSnx), onde x =O; 0,05; 0,10 e 0,15, no intervalo de temperaturas de 4,2 a 800°K. Foram também efetua das medidas nas ligas de Heusler Ni 2MnX,. com X = In, Sn ou Sb, no intervalo de 4,2 a 300°K . As curvas experimentais mostram clar amente a importância do caráter fe rromagnetico nas re sistivi dades das ligas. Os resultados obtidos para as ligas de cobre, bem como para a liga Ni 2MnSn, estão em concórdância com uma interpretação em termos dos modelos de Bloch-Grüneisen e de desordem de spin, e falham quando tentamos obter evidên cias de espalhamento s-d para os elétrons de condução. Esse não é o caso para as ligas Ni 2Mnln e Ni 2MnSb, em que a presença de processo de espalhamento eletrônico interbanda (s-d), via fonon, foi detectada. Especialmente para as duas últimas ligas, são sugeridas experiências de calor especifico e de foto-emissividade eletrônica. / Electrical resistivity measurements have been performed on the Cu 2Mn (Al 1 -xsnx) Heusler alloys, where x =O, 0.05, 0.10 and 0.15, in the temperature range of 4.2 to 800 o K. Measurements have also been made on the Ni 2MnX Heusler alloys, with X = In, Sn or Sb, in the range of 4.2 to 300°K. The experimental curves clearly show the importance of the ferromagnetic character on the alloys resistivities. The results obtained for the copper allooys, as well as for the Ni 2MnSn alloy, are in ágreement with an interpretation in terms of Bloch-Grüneisen and spin-disorder models, and fail to provide evidences of s-d scattering for the conduction electrons. This is not the case for the Ni 2Mnln and Ni 2MnSb alloys, in which the presence of (s-d) interband electronic scattering process, via phonon, was detected. Specially for the two last alloys specific heat and electronic photo-emissivity experiments are suggested.
60

Influência da idade e cura do concreto na resistividade elétrica / Influence of age and concrete cure in surface electrical resistivity

Perez, Elva Wendolyn Ramirez 02 December 2015 (has links)
Submitted by Luciana Ferreira (lucgeral@gmail.com) on 2016-04-15T11:03:31Z No. of bitstreams: 2 Dissertação - Elva Wendolyn Ramírez Pérez - 2015.pdf: 2312393 bytes, checksum: f6136ce7273f0ccf860c0380da251fa1 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2016-04-15T11:10:18Z (GMT) No. of bitstreams: 2 Dissertação - Elva Wendolyn Ramírez Pérez - 2015.pdf: 2312393 bytes, checksum: f6136ce7273f0ccf860c0380da251fa1 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Made available in DSpace on 2016-04-15T11:10:18Z (GMT). No. of bitstreams: 2 Dissertação - Elva Wendolyn Ramírez Pérez - 2015.pdf: 2312393 bytes, checksum: f6136ce7273f0ccf860c0380da251fa1 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Previous issue date: 2015-12-02 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / The surface electrical resistivity of the fresh and hardened concrete states can be influenced by factors such as degree of hydration, the water / binder ratio (w / b), aggregate content and existence of armour. This study objective is to evaluate the performance and behavior of the electrical resistivity of the concrete´s surface based on the influence of hidratation process, curing time and the w/b ratio. The actual measured were divided into three groups, where C-0,81 represents the specific group with w/b ratio= 0.81 and compressive strength =20 MPa; C-0,50 is the concrete with w/b ratio= 0.50 and 40 MPa; and C-0,35 represents the concrete with the ratio of 0.35 and compressive strength of 60 MPa. The curing procedures applied to the three groups were: dry cure, cure submerged up to seven days and cure submerged up to fourteen days. This study the results showed that in the higher ratio w/b , the porosity of the sample is greater, and this increases the electrical resistivity. Regarding the dry cured concrete, it had higher resistivity vs submerged conrete. The results also showed that greater the degree hydratation in the sample the greater the resistivity. / A resistividade elétrica superficial do concreto nos estados fresco e endurecido pode ser influenciada por alguns fatores, como por exemplo grau de hidratação, relação água/aglomerante (a/ag), procedimento de cura, teor de agregado e existência de armadura. Este trabalho tem o objetivo de avaliar o desempenho e o comportamento da resistividade elétrica superficial do concreto tendo como base a influência do grau de hidratação, tempo de cura e relação a/ag. Os concretos dosados foram divididos em três grupos, onde C-0,81 representa o grupo de concretos com relação a/ag de 0,81 e 20 MPa de resistência à compressão; C-0,50 representa os concretos com relação a/ag de 0,50 e 40 MPa; e C-0,35 representa os concretos com 0,35 de relação a/ag e 60 MPa de resistência à compressão. Os procedimentos de cura aplicados aos três grupos foram: cura seca, cura submersa até os sete dias e cura submersa até os quatorze dias. No presente estudo, os resultados mostraram que quanto maior a relação a/ag, maior será a porosidade da mistura que, por sua vez, eleva a resistividade elétrica. No que tange ao procedimento de cura, os concretos curados a seco apresentaram maiores índices de resistividade que os concretos submersos. Os resultados ainda mostraram que quanto maior é o grau de hidratação, maior será a resistividade correspondente.

Page generated in 0.2901 seconds