Spelling suggestions: "subject:"ressonante"" "subject:"ressonance""
21 |
Desenvolvimento de um dispositivo de teste din?mico para avalia??o da estabilidade de imagens de resson?ncia magn?tica funcionalCapaverde, Alexandre da Silva 20 March 2014 (has links)
Made available in DSpace on 2015-04-14T13:56:31Z (GMT). No. of bitstreams: 1
459163.pdf: 4581609 bytes, checksum: 9c2157ae4d5d0fdce6a15da19b6c7c45 (MD5)
Previous issue date: 2014-03-20 / Among the protocols for quality control of magnetic resonance equipment is to evaluate the stability of the sequence EPI (Echo-Planar Imaging), this used in imaging method called functional magnetic resonance imaging. Nowadays, static and homogeneous test devices are recommended for this review. This work proposes the development of a dynamic test device for quality control of the stability of EPI sequences. The test device consists of an acrylic box, where two brackets are inserted, through which passes a tube in which a liquid circulates signal producing. At certain times during acquisition, is injected through a fuel injection pump, a solution of copper sulfate and gadolinium in order to produce variations in signal intensity in the region of the hose, over time. To validate the device, images were acquired in a magnetic resonance with 3.0 T during the period of a month, on Monday morning and evening and on Tuesday morning in order to evaluate machine wear. For each acquisition were evaluated: (1) the standard deviation of average normalized signal intensity in the region of the images corresponding to the homogeneous region of the liquid; (2) the average normalized signal intensity at baseline and injection in the image region corresponding to the hose; (3) the difference between the mean of baseline and injection; (4) the signal to noise ratio in the region of the images corresponding to the homogeneous region. As a result there was an increase in the standard deviation in the homogeneous region of the liquid from the acquisitions made on Monday evening. There was also wide variation in the difference between the baseline and injection line, and in one day this went from approximately 0.3 to 0.6 after five acquisitions and on another day of approximately 0.7 to 0.5 after a single acquisition. The test has been validated for use in 3.0 T equipment and that additional tests are needed to verify the reproducibility of the results / Dentre os protocolos de controle da qualidade de equipamentos de resson?ncia magn?tica est? a avalia??o da estabilidade da sequ?ncia EPI (Echo-Planar Imaging), esta utilizada no m?todo de imageamento denominado resson?ncia magn?tica funcional. Atualmente, dispositivos de teste est?ticos e homog?neos s?o recomendados para esta avalia??o. Este trabalho prop?e o desenvolvimento e valida??o de um dispositivo de teste din?mico para avaliar a estabilidade de sequ?ncias EPI. O dispositivo de teste consiste em uma caixa de acr?lico, onde s?o inseridos dois suportes, atrav?s dos quais passa uma mangueira, na qual circula um l?quido produtor de sinal. Em determinados momentos durante a aquisi??o, ? injetada, por meio de uma bomba injetora, uma solu??o de sulfato de cobre e gadol?nio com o objetivo de produzir varia??es na intensidade de sinal, na regi?o da mangueira, ao longo do tempo. Para validar o dispositivo, foram adquiridas imagens em um equipamento de resson?ncia magn?tica de 3,0 T, durante o per?odo de um m?s, nas segundas-feiras pela manh? e pela noite e nas ter?as-feiras pela manh? para avaliar o desgaste do equipamento. Para cada aquisi??o foram avaliados: (1) o desvio padr?o da m?dia de intensidade de sinal normalizada na regi?o das imagens correspondente ? regi?o homog?nea do l?quido; (2) a m?dia de intensidade de sinal normalizada nas linhas de base e de inje??o na regi?o da imagem correspondente ? mangueira; (3) a diferen?a entre as m?dias das linhas de base e de inje??o; (4) a raz?o sinal-ru?do na regi?o das imagens correspondente ? regi?o homog?nea. Como resultado houve um aumento no desvio padr?o na regi?o homog?nea do l?quido nas aquisi??es realizadas nas segundas-feiras ? noite. Houve ainda grande varia??o na diferen?a entre a linha de base e a linha inje??o, sendo que em um dia esta passou de aproximadamente 0,3 para 0,6 ap?s cinco aquisi??es e em outro dia de aproximadamente 0,7 para 0,5 ap?s uma ?nica aquisi??o. O dispositivo de teste foi validado para utiliza??o em equipamentos de 3,0 T sendo que testes adicionais s?o necess?rios para verificar a reprodutibilidade dos resultados obtidos.
|
22 |
Desenvolvimento e avalia??o de prot?tipo para estudos de neuroimagem : est?mulo olfativoMondini, Renata 03 November 2014 (has links)
Made available in DSpace on 2015-04-14T13:56:35Z (GMT). No. of bitstreams: 1
465061.pdf: 182147 bytes, checksum: f7a4815079fd1da1390d1f0d759a33b8 (MD5)
Previous issue date: 2014-11-03 / This dissertation presents the development and evaluation of a prototype for the stimulus of the olfactory system, which will be employed in the study of neuroimages gathered by functional magnetic resonance image (fRMI). Basic requirements for the prototype include: safety, human physiology and environmental compatibility, homogeneous release of aerosolized stimuli, accurate control of pressure and flow conditions, support for up to three distinct substances, and substance mixing capability. Digital image processing techniques were used in evaluation process through the usage of Matlab in order to better assess the reliability and reproducibility in the evaluation of the of the samples released under controlled constant pressure of 3.5+/- 0.3 kgf/cm?, different flows (4 l/min, 6 l/min, 8 l/min and 10 l/min), and different duration periods (10s, 15s, 20s, 30s, 60s and 90s). Charts with the image profiles, histograms and statistical data were generated and analyzed. The delay in the system, important information for any study in fRMI, was measured using an oxygen sensor and custom software solution. Experiments for the determination of the amount of substance required and the real capability of mixing substances were performed with parameters based on the results from the digital image processing analysis. / Esta disserta??o de mestrado apresenta o desenvolvimento e a avalia??o de um prot?tipo para estimular o sistema olfativo, o qual ser? empregado em estudos de neuroimagens obtidas pela modalidade de resson?ncia magn?tica funcional.
Para o desenvolvimento do prot?tipo foram definidos requisitos b?sicos que o sistema deveria possuir: seguran?a, compatibilidade com o ambiente e com as caracter?sticas fisiol?gicas humanas, dispensar amostra aerossolizada, precis?o para controlar e regular vaz?o e press?o, capacidade para tr?s subst?ncias distintas e possibilidade de mistur?-las.
A avalia??o utilizou t?cnicas de processamento de imagens digitais com a utiliza??o do software Matlab com a finalidade de estudar a confiabilidade e reprodutibilidade na quantifica??o da amostra dispensada utilizando press?o fixa de 3,5 +/- 0,3 kgf/cm? e as vari?veis fluxo (4 l/min, 6 l/min, 8 l/min e 10 l/min) e tempo (10s, 15s, 20s, 30s, 60s e 90s). Os resultados foram analisados atrav?s de gr?ficos de perfil dos pixels, histogramas e dados estat?sticos das imagens.
O atraso do sistema, dado fundamental para pesquisas em resson?ncia magn?tica funcional, foi medido com a utiliza??o de um sensor de oxig?nio e um software desenvolvido em LabVIEW.
Experimentos para medir o consumo e a possibilidade de misturar as amostras foram realizados utilizando os resultados obtidos com a valida??o por processamento de imagens digitais.
|
23 |
Desenvolvimento de t?cnica de resson?ncia nuclear magn?tica r?pida e de respira??o livre em pacientes com fibrose c?sticaOliveira, Marinez Josefina Casarotto de 31 July 2017 (has links)
Submitted by PPG Pediatria e Sa?de da Crian?a (pediatria-pg@pucrs.br) on 2017-11-28T18:15:11Z
No. of bitstreams: 1
Tese-MC.pdf: 2529108 bytes, checksum: d7557f03bd9245db7376252ca33303d0 (MD5) / Approved for entry into archive by Caroline Xavier (caroline.xavier@pucrs.br) on 2017-12-04T12:45:28Z (GMT) No. of bitstreams: 1
Tese-MC.pdf: 2529108 bytes, checksum: d7557f03bd9245db7376252ca33303d0 (MD5) / Made available in DSpace on 2017-12-04T12:47:32Z (GMT). No. of bitstreams: 1
Tese-MC.pdf: 2529108 bytes, checksum: d7557f03bd9245db7376252ca33303d0 (MD5)
Previous issue date: 2017-07-31 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior - CAPES / Introduction-objective: Cystic fibrosis is the most common genetic disease in the Caucasian population. The reduction in life expectancy is due to progressive lung disease, characterized by severe changes in the pulmonary structure, more precisely, bronchiectasis and air catabolization. Computed tomography of the chest is considered the most sensitive method to monitor lung disease in cystic fibrosis. The main disadvantage is the patient's exposure to radiation. Magnetic resonance imaging of the chest, a radiation-free technique, has been introduced as an alternative to computed tomography. Magnetic resonance has been compared to computed tomography in several studies using various sequences, but none have used the combined sensing, parallel imaging, and golden-angle radial sampling technique. The aim of this study was to evaluate the combined golden-angle radial technique of magnetic resonance imaging in patients with cystic fibrosis in relation to conventional magnetic resonance imaging and computed tomography of the chest. Cystic fibrosis has been compared to computed tomography in several studies using various sequences, but none have used the combined sensing, parallel imaging, and golden-angle radial sampling technique. The aim of this study was to evaluate the combined radial-angle golden-angle technique of magnetic resonance imaging in patients with cystic fibrosis in relation to conventional magnetic resonance imaging and computed tomography of the chest.
Methods: Computed tomography and magnetic resonance of the chest were performed in 29 patients with cystic fibrosis who were followed at the pediatric pulmonology outpatient clinic of the S?o Lucas Hospital of the Pontifical Catholic University of Rio Grande do Sul. The Cartesian K-space sampling and, after the free-breathing magnetic resonance techniques, using the Golden_Angle Radial Sparse Parallel technique. Magnetic resonance imaging and computed tomography of the chest were evaluated by two independent observers using the Helbich-Bhalla score. Intraclass correlation coefficient and Bland-Altman analysis were used to assess agreement and reproducibility in the Helbich-Bhalla severity score. No patient was sedated or used contrast medium.
Results: Intraclass correlation coefficients and the Bland-Altman graphical model between the Helbich-Bhalla scores and the evaluated methods, computed tomography, magnetic resonance and free breating magnetic resonance , showed very strong correlations in all comparisons of the total scores (ICCCT -RM = 97%, ICCCT-FB-RM = 96% and ICCCT-FB-RM = 99%). The association of the Helbich-Bhalla score of both computed tomography and magnetic resonance with pulmonary function tests were significant, mainly in relation to the severity of bronchiectasis and thickening of the bronchial walls.
Conclusion: This study demonstrated that the new technique of free-breathing magnetic resonance and combination of compressed sensing, parallel imaging and radial golden-angle sampling, showed a good concordance with computed tomography in the assessment of pulmonary alterations in cystic fibrosis. The combined golden-angle radial technique can be used in clinical practice to monitor fibrocystic lung disease, and demonstrates particular value for patients who can not hold their breath during the examination. / Introdu??o-objetivo: Fibrose c?stica ? a doen?a gen?tica mais comum na popula??o caucasiana. A redu??o da expectativa de vida ? devido ? doen?a pulmonar progressiva, caracterizada por mudan?as severas na estrutura pulmonar, mais precisamente, bronquiectasias e alcaponamento de ar. A tomografia computadorizada de t?rax ? considerada o m?todo mais sens?vel para monitorar a doen?a pulmonar na fibrose c?stica. A principal desvantagem ? a exposi??o do paciente ? radia??o. A resson?ncia magn?tica de t?rax, t?cnica livre de radia??o, tem sido introduzida como uma alternativa ? tomografia computadorizada. A resson?ncia magn?tica tem sido comparada ? tomografia computadorizada em v?rios estudos usando v?rias sequ?ncias, mas, nenhuma utilizou a t?cnica de sensoriamento comprimido, imagem paralela e amostragem golden-angle radial combinada. O objetivo deste estudo foi avaliar a t?cnica de golden-angle radial combinada de resson?ncia magn?tica de t?rax em pacientes com fibrose c?stica em rela??o ? tomografia computadorizada e a resson?ncia magn?tica convencional de t?rax.
M?todos: Foram realizados exames de tomografia computadorizada e resson?ncia magn?tica de t?rax em 29 pacientes com fibrose c?stica que eram acompanhados no ambulat?rio de pneumologia pedi?trica do Hospital S?o Lucas da Pontif?cia Universidade Cat?lica do Rio Grande do Sul. Os exames, foram realizados utilizando, primeiro, a amostragem de K-espa?o cartesiano e, ap?s, as t?cnicas de resson?ncia magn?tica com respira??o livre, utilizando a t?cnica Golden_Angle Radial Sparse Parallel. As imagens de resson?ncia magn?tica e tomografia computadorizada de t?rax foram avaliadas por dois observadores independentes utilizando o escore de Helbich-Bhalla. Coeficiente de correla??o intraclasse e an?lise de Bland-Altman foram usados para avaliar a concord?ncia e a reprodutibilidade no escore de severidade de Helbich-Bhalla. Nenhum paciente foi sedado ou usado meio de contraste.
Resultados: Os coeficientes de correla??o intraclasse e o modelo gr?fico de Bland-Altman entre os escores de Helbich-Bhalla e os m?todos avaliados, tomografia computadorizada, resson?ncia magn?tica e resson?ncia magn?tica de respira??o livre, evidenciaram, em todas as compara??es dos escores totais, correla??es muito fortes (ICCCT-RM = 97%; ICCCT-FB-RM = 96% e ICCCT- FB-RM=99%). A associa??o do escore de Helbich-Bhalla, tanto da tomografia computadorizada como das imagens de resson?ncia magn?tica, com os testes de fun??o pulmonar foram significativas, principalmente, em rela??o ? severidade das bronquiectasias e espessamento das paredes br?nquicas.
Conclus?o: Este estudo demonstrou que a nova t?cnica de resson?ncia magn?tica com respira??o livre e combina??o de sensoriamento comprimido, imagem paralela e amostragem golden-angle radial, mostrou uma boa concord?ncia com a tomografia computadorizada na avalia??o das altera??es pulmonares na fibrose c?stica. A t?cnica de golden-angle radial combinada pode ser utilizada na pr?tica cl?nica para acompanhamento de doen?a pulmonar fibroc?stica, e demonstra particular valor para os pacientes que n?o conseguem suspender a respira??o durante o exame.
|
24 |
An?lise da din?mica da rede cerebral por meio da teoria dos grafosCouto, Jefferson Leal 26 January 2015 (has links)
Submitted by Setor de Tratamento da Informa??o - BC/PUCRS (tede2@pucrs.br) on 2015-06-19T11:11:46Z
No. of bitstreams: 1
470809 - Texto Completo.pdf: 6861498 bytes, checksum: 8ff1a79ef3ddb913c671a8d1f821428d (MD5) / Made available in DSpace on 2015-06-19T11:11:46Z (GMT). No. of bitstreams: 1
470809 - Texto Completo.pdf: 6861498 bytes, checksum: 8ff1a79ef3ddb913c671a8d1f821428d (MD5)
Previous issue date: 2015-01-26 / With the use of resting state functional magnetic resonance imaging (rs-FMRI) we can
analyze the functional connectivity between different brain areas. However, recent studies
show that this connectivity undergoes fluctuations over time (also known as dynamic Resting
State). In this study, the analysis of Graph Theoretical (GT) metrics will be used to assess the
variability of the correlation between these areas, through a windowing technique. For this
study, we used images of 15 patients with ADHD that underwent a clinical treatment with the
medication (Ritalin?). Images were taken before treatment (Visit 1 - PRE) and after 6 months
of treatment (Visit 2 - POST). We determined the GT metrics for windows between 75 and
150s generated from the correlation between the various groups after applying a mask that
divided the brain into 190 regions. The results showed statistically significant differences
between visits for the metric of the characteristic path length. Were also generated graphs that
show the fluctuations of each of the metrics. GT analysis identified an increase in the average
value of the characteristic path length after drug treatment for most patients. However, some
patients behaved differently and therefore results are not conclusive. Furthermore, it was
observed that there is a dependence of GT metrics based on the size of the window.
Conclusion show that based on the analysis of the dynamics of the brain network by the GT
metrics show to be an auxiliary tool in the diagnosis of ADHD, but still requires further
studies to test the viability of this tool as a diagnostic test in neuroimaging. / Atrav?s da Resson?ncia Magn?tica Funcional no estado de repouso (RMf-er) podemos
analisar a conectividade funcional entre as diversas ?reas do c?rebro. Entretanto, estudos
recentes mostram que a correla??o desta conectividade sofre flutua??es ao longo do tempo
(Dynamic Resting State). No presente trabalho, foi feita uma an?lise por interm?dio de
m?tricas da Teoria dos Grafos da variabilidade da correla??o entre as ?reas cerebrais atrav?s
de t?cnicas de janelamento. Para este estudo, foram utilizadas imagens de 15 pacientes com
transtorno de d?ficit de aten??o com hiperatividade (TDAH) e que passaram por um
tratamento cl?nico com o uso do medicamento (Ritalina?). As imagens de resson?ncia foram
adquiridas antes do pr?-tratamento (Visita 1 - PR?) e ap?s 6 meses de tratamento (Visita 2 ?
P?S). Foram desenvolvidas m?tricas de Teoria dos Grafos (TG) para janelas entre 75 e 150s
geradas a partir da correla??o entre as diversas regi?es, ap?s aplicar uma m?scara que dividiu
o c?rebro em 190 ?reas. Os resultados encontrados apresentaram dados estatisticamente
relevantes para a m?trica do comprimento do caminho caracter?stico. Foram gerados tamb?m
gr?ficos que apresentam as flutua??es de cada uma das m?tricas. Na an?lise dos gr?ficos foi
poss?vel identificar um aumento do valor m?dio do comprimento do caminho caracter?stico
ap?s o tratamento com o f?rmaco para a maioria dos pacientes. Entretanto, alguns pacientes
tiveram comportamento oposto, n?o sendo portanto conclusivo. Al?m disso, observou-se que
existe uma depend?ncia das m?tricas de TG para a janela adotada. Concluiu-se, baseado nos
dados encontrados, que a an?lise da din?mica da rede cerebral pela m?trica dos grafos ? uma
ferramenta auxiliar para o entendimento do comportamento funcional do c?rebro e dos
dist?rbios, mas que ainda requer mais estudos para que venha a ser adotada como apoio ao
diagn?stico em neuroimagem.
|
25 |
Estudo da gordura abdominal e esteatose hep?tica atrav?s de exames de imagem em adolescentes normais e obesosEloi, Juliana Cristina 24 March 2015 (has links)
Submitted by Setor de Tratamento da Informa??o - BC/PUCRS (tede2@pucrs.br) on 2015-07-03T20:19:07Z
No. of bitstreams: 1
471666 - Texto Parcial.pdf: 551139 bytes, checksum: 5bb0227a6e5feda8fdccb22fc3a5fdf1 (MD5) / Made available in DSpace on 2015-07-03T20:19:07Z (GMT). No. of bitstreams: 1
471666 - Texto Parcial.pdf: 551139 bytes, checksum: 5bb0227a6e5feda8fdccb22fc3a5fdf1 (MD5)
Previous issue date: 2015-03-24 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior - CAPES / Conselho Nacional de Pesquisa e Desenvolvimento Cient?fico e Tecnol?gico - CNPq / BACKGROUND: Obesity has been a worldwide public health problem, with a high prevalence in children and adolescents. Visceral fat is associated with increased metabolic risk and more subject to complications in relation to chronic diseases in adulthood. One of them is the nonalcoholic fatty liver disease alcoholic. Several diagnostic methods have been used to measure visceral fat and liver fat infiltration. MRI is an excellent accuracy in assessing visceral and subcutaneous abdominal fat in studies in adults and children mainly with the use of MRI 1.5T. One of our goals was to evaluate the 3T MRI to measure the visceral and subcutaneous abdominal fat, correlating anthropometric and laboratory values in obese and normal-weight adolescents. Moreover, ultrasound has been used as an evaluation tool of fatty infiltration of the liver. The hepatorenal index has been used in order to objectify the evaluation of steatosis. The aim of our study is to evaluate the hepatorenal index in the same group of adolescents, correlating it with anthropometric and laboratory parameters.
MATERIAL AND METHODS: A prospective, observational study. Fifty-seven adolescents were divided into two groups: overweight / obese (24) and normal (33). All patients underwent ultrasonography, magnetic resonance 3T, anthropometric and laboratory tests. The images of US and MRI were analyzed using the ImageJ softwer. All variables were correlated with visceral and subcutaneous fat and the HRI.
RESULTS: The results obtained in this study were divided into two articles. The first correlated the area and the percentage of visceral and subcutaneous fat with anthropometric and laboratory values in obese and normal weight. We observed a correlation between waist circumference in both obese and normal weight. In obese, the total cholesterol/HDL, insulin levels and HOMA-IR were positively correlated with visceral fat. In both groups, the positive correlation was also observed at the level of triglycerides. In the second article, the IHR was positively correlated with DBP and AST in obese, and negatively correlated with HDL. In eutrophic, only males was correlated with the HRI.
CONCLUSION: both visceral fat and subcutaneous evaluated by MRI 3T as the HRI evaluated by the US, are easily analyzed with computer analysis using the ImageJ softwer. Waist circumference is a good predictor of both abdominal fat in obese as in normal weight. In obese, visceral fat is associated with insulin resistance-related indicators (insulin and HOMA-IR) and dyslipidemia (total cholesterol / HDL). HDL as a protection in the obese. Triglycerides are visceral fat predictors in both obese as in normal weight. The IHR correlates with DBP and ALT in obese, which again have a protective HDL. In eutrophic, the male has a higher positive correlation with hepatorenal index. / INTRODU??O: a obesidade vem sendo um problema de sa?de p?blica mundial, apresentando uma preval?ncia alta em crian?as e adolescentes. A gordura visceral est? associada a um maior risco metab?lico e mais sujeita a complica??es no que se refere a doen?as cr?nicas na vida adulta. Uma dessas complica??es ? a doen?a hep?tica gordurosa n?o alc?olica (esteatose hep?tica). Diversos m?todos diagn?sticos t?m sido usados para mensurar a gordura visceral e a infiltra??o gordurosa hep?tica. A resson?ncia magn?tica (RM) apresenta uma excelente acur?cia na avalia??o da gordura abdominal visceral e subcut?nea em estudos realizados em adultos e crian?as, principalmente com o uso da RM de 1,5 Tesla. Um dos nossos objetivos foi avaliar a RM de 3 Tesla na mensura??o da gordura abdominal visceral e subcut?nea, correlacionando par?metros antropom?tricos e valores laboratoriais em adolescentes obesos e eutr?ficos. Por outro lado, ultrassonografia (US) tem sido usada como ferramenta de avalia??o da esteatose hep?tica. Um dos par?metros utilizados, ? o ?ndice hepatorrenal (IHR), com a finalidade objetivar a avalia??o da esteatose. O objetivo do nosso estudo ? avaliar o ?ndice hepatorrenal no mesmo grupo de adolescentes, correlacionando-o com antropometria e par?metros laboratoriais. Analisar as imagens obtidas tanto em RM como na US como o aux?lio de um programa de dom?nio p?blico.
MATERIAL E M?TODOS: estudo prospectivo, transversal, observacional. Cinquenta e sete adolescentes foram divididos em dois grupos: sobrepeso/obesos (24) e eutr?ficos (33). Todos realizaram ultrassonografia, resson?ncia magn?tica 3T, avalia??o antropom?trica e exames laboratoriais. As imagens da US e RM foram analisadas com utiliza??o do programa ImageJ. Todas as vari?veis foram correlacionadas com a gordura visceral e subcut?nea e com o IHR. RESULTADOS: os resultados obtidos nesse estudo foram divididos em dois artigos. No primeiro, correlacionamos a ?rea e o percentual de gordura visceral e subcut?nea com par?metros antropom?tricos e valores laboratoriais em obesos e eutr?ficos. Observamos uma correla??o da circunfer?ncia abdominal tanto em obesos como eutr?ficos com a gordura visceral. No obesos a rela??o colesterol total/HDL, os n?veis de insulina e o modelo de avalia??o da homeostase - resist?ncia ? insulina (HOMA-IR) correlacionaram-se positivamente com a gordura visceral. Em ambos os grupos, a correla??o positiva tamb?m foi observada com o n?vel de triglicer?deos. No segundo artigo, o IHR correlacionou-se positivamente com tens?o arterial diast?lica e transaminase glut?mica pir?vica nos obesos, sendo negativamente correlacionado com o HDL. Nos eutr?ficos, apenas o sexo masculino esteve correlacionado com o IHR.
CONCLUS?O: tanto a gordura visceral como subcut?nea avaliadas pela RM 3T quanto o IHR avaliado pela US, s?o facilmente analisados com an?lise computadorizada com utiliza??o do programa ImageJ. A circunfer?ncia abdominal ? um bom preditor de gordura abdominal tanto em obesos como em eutr?ficos. Nos obesos, a gordura visceral est? associada com indicadores relacionados ? resist?ncia ? insulina (insulina e HOMA-IR) e dislipidemia (rela??o colesterol total/HDL). O HDL atua como protetor nos obesos. Os triglicer?deos s?o preditores de gordura visceral tanto em obesos como em eutr?ficos. O IHR correlaciona-se com a tens?o arterial diast?lica e com a transaminase glut?mica pir?vica em obesos, que novamente apresentam como protetor o colesterol HDL. Nos eutr?ficos, o sexo masculino apresenta maior correla??o positiva com o ?ndice hepatorrenal.
|
26 |
Feature selection for neuroimaging applied to word-category identification in dyslexic childrenFroehlich, Caroline Seligman 26 February 2015 (has links)
Submitted by Setor de Tratamento da Informa??o - BC/PUCRS (tede2@pucrs.br) on 2015-08-10T20:11:34Z
No. of bitstreams: 1
473233 - Texto Completo.pdf: 3157211 bytes, checksum: 46d1f58d384ad33725fbb29ba8257582 (MD5) / Made available in DSpace on 2015-08-10T20:11:34Z (GMT). No. of bitstreams: 1
473233 - Texto Completo.pdf: 3157211 bytes, checksum: 46d1f58d384ad33725fbb29ba8257582 (MD5)
Previous issue date: 2015-02-26 / Dyslexia is a developmental reading disorder characterized by persistent difficulty to learn
how to read fluently despite normal cognitive abilities. It is a complex learning difficulty that is often hard to quantify. Traditional methods based on questionnaires are not only imprecise in quantifying dyslexia, they are also not very accurate in diagnosing it. Consequently, we aim to investigate the neural underpinnings of this reading disorder in children and teenagers, as part of a project that aims to unravel some of the neurological causes of dyslexia among children at preliteracy age. In this dissertation, we develop a study of brain activation within functional MRI scans taken when children carried out pseudo-word tasks. Our study expands recently developed machine learning-based techniques that identify which type of word the study participants were reading based solely on participant?s brain activation. Because such functional MRI data contains
about 30,000 voxels, we try several feature selection techniques for removing voxels that are not very helpful for the machine learning algorithm.This procedure is widely used for maximizing the machine learning algorithm accuracy, and some of these feature selection approaches allowed us to achieve very accurate results. / Dislexia ? um transtorno de aprendizagem de leitura caracterizado pela dificuldade persistente
de uma crian?a a aprender a ler fluentemente, mesmo apresentando outras habilidades
cognitivas normais. A dislexia ? uma dificuldade de aprendizado complexo e dif?cil de diagnosticar.
M?todos de diagnostico tradicionais, como question?rios, n?o s?o somente imprecisos em quantificar
a dislexia, como tamb?m tamb?m n?o s?o precisos no diagn?stico. Consequentemente, n?s
visamos investigar a base neural deste transtorno de leitura em crian?as e adolescentes, como parte
de um projeto que tem como objetivo desvendar algumas das causas neurol?gicas da dislexia entre
crian?as em alfabetiza??o. Nesta disserta??o, desenvolvemos um estudo da ativa??o do c?rebro
com o uso de exames de imagem de resson?ncia magn?tica (IRM) funcional coletados enquanto
as crian?as realizavam uma tarefa de pseudo-palavras. Este estudo amplia t?cnicas de aprendizado
de m?quina recentemente desenvolvidas que identificam que tipo de palavra os participantes de um
estudo estavam lendo, baseado somente em sua atividade neural. Como dados de IRM funcional
contem aproximadamente 30.000 voxels, neste trabalho experimentamos com algumas t?cnicas de
sele??o de features para remover voxels que n?o s?o relevantes para o algoritmo de aprendizado
de m?quina. Esse procedimento ? amplamente utilizado para maximizar a acur?cia do algoritmo, e
algumas abordagens de feature selection permitem atingir resultados muito precisos.
|
27 |
Desempenho da resson?ncia magn?tica para avalia??o das altera??es pulmonares em crian?as com fibrose c?sticaAthayde, Renata Anele 18 August 2015 (has links)
Submitted by Setor de Tratamento da Informa??o - BC/PUCRS (tede2@pucrs.br) on 2015-10-29T10:21:57Z
No. of bitstreams: 1
475918- Texto Parcial.pdf: 356208 bytes, checksum: a918d2df47ed4b4e5d722fc922cb0fca (MD5) / Made available in DSpace on 2015-10-29T10:21:57Z (GMT). No. of bitstreams: 1
475918- Texto Parcial.pdf: 356208 bytes, checksum: a918d2df47ed4b4e5d722fc922cb0fca (MD5)
Previous issue date: 2015-08-18 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior - CAPES / Introduction : Cystic fibrosis is a chronic disease that requires regular monitoring and testing. Chest CT is the gold standard to the evaluation of the pulmonary parenchyma, but because of the risk caused by radiation, technical alternatives should be evaluated. MRI is a test that does not use radiation. The aim of this study is to evaluate the performance of MRI chest and correlated with clinical parameters such as spirometry, Shawchman clinical score and the 6-minute walk test. Methods : 19 patients with cystic fibrosis Clinic underwent magnetic resonance of the chest, 6-minute walk test, FEV1 and clinical Shwachman score. MR score was evaluated and correlated with other parameters. Results : MRI correlated with the 6-minute walk test and the clinical score of Shwachman, but not with FEV1. Conclusion : MRI is a good alternative for airway and lung parenchyma assessment in patients with CF, showing a significant correlation with the6-minute walk test and the clinical score of Shwachman. / Introdu??o : a fibrose c?stica ? uma doen?a cr?nica, que necessita de acompanhamento e exames regulares. A TC de t?rax ? o padr?o-ouro para avalia??o das altera??es do par?nquima pulmonar, mas pelo risco causado pela radia??o, t?cnicas alternativas devem ser avaliadas. A RM ? um exame que n?o utiliza radia??o. O objetivo desse estudo ? avaliar o desempenho da RM de t?rax, correlacionando com par?metros cl?nicos, como espirometria, escala de Shawchman e o teste de caminhada de 6 minutos. M?todos : 19 pacientes do ambulat?rio de fibrose c?stica realizaram resson?ncia magn?tica de t?rax, teste de caminhada de 6 minutos, VEF1 e escore clinico de Shwachman. Foi avaliado o escore de RM e correlacionado com os outros par?metros. Resultados : a RM apresentou correla??o com o teste de caminhada de 6 minutos e com o escore cl?nico de Shwachman, mas n?o apresentou com o VEF1. Conclus?o : A RM ? uma boa alternativa para avalia??o de via a?rea e par?nquima pulmonar em pacientes com FC, mostrando correla??o com o teste de caminhada de 6 minutos e com o escore cl?nico de Shwachman.
|
28 |
Influ?ncia da informa??o cl?nica na reprodutibilidade da interpreta??o de imagens por resson?ncia magn?tica da articula??o temporomandibularBisi, Maur?cio Andr? 17 March 2011 (has links)
Made available in DSpace on 2015-04-14T13:29:53Z (GMT). No. of bitstreams: 1
430603.pdf: 8044498 bytes, checksum: 9bbde27c42dcd9235f5e7c110e567949 (MD5)
Previous issue date: 2011-03-17 / A obten??o do diagn?stico das disfun??es temporomandibulares (DTMs) se faz atrav?s de uma anamnese acurada e do uso de exames de imagem complementares. O objetivo deste estudo foi avaliar a influ?ncia da informa??o cl?nica na reprodutibilidade intra e interexaminadores na interpreta??o de imagens por resson?ncia magn?tica (IRM) da articula??o temporomandibular (ATM). Quarenta exames de resson?ncia magn?tica foram avaliados por sete especialistas em disfun??o temporomandibular e dor orofacial em tr?s momentos distintos. Na ?ltima avalia??o foi informado aos avaliadores os dados cl?nicos dos pacientes. A reprodutibilidade intra-examinador foi avaliada mediante utiliza??o da medida de concord?ncia Cohen s Kappa e, a concord?ncia interexaminadores, pelo teste de Friedman. A hipermobilidade articular foi a patologia que obteve maior concord?ncia (kappa 0,770) e a altera??o degenerativa no osso temporal foi a de menor concord?ncia (kappa 0,447) entre os examinadores. A informa??o cl?nica n?o teve influ?ncia na interpreta??o de imagens por IRM da ATM e n?o houve diferen?a estatisticamente significativa entre os avaliadores quanto a sua reprodutibilidade neste modelo de estudo.
|
29 |
Avalia??o do ap?ndice cecal normal em crian?as atrav?s da resson?ncia magn?ticaValduga, Simone Gianella 26 November 2007 (has links)
Made available in DSpace on 2015-04-14T13:32:34Z (GMT). No. of bitstreams: 1
398804.pdf: 2160264 bytes, checksum: ded63f44ec5fe59611c91a380d81d1fc (MD5)
Previous issue date: 2007-11-26 / OBJETIVOS: O objetivo deste estudo ? avaliar o ap?ndice cecal normal em crian?as e adolescentes assintom?ticos atrav?s da RM. MATERIAIS E M?TODOS: O ap?ndice cecal foi avaliado atrav?s da RM em 40 volunt?rios assintom?ticos, 22 do sexo feminino e 18 masculinos, com idade variando de 8 e 18 anos e m?dia de 12 anos. O estudo foi aprovado pelo comit? de ?tica m?dica desta institui??o. O protocolo de RM incluiu as sequ?ncias: axial T1 fast spin-echo (T1 FSE); T2 fast spin-echo nos planos axial e coronal (T2 FSE) e axial T2 fast spin-echo com supress?o de gordura (T2 FSE FAT SAT). Os estudos foram avaliados por 2 examinadores independentes e a concord?ncia entre os 2 foi avaliada pelo coeficiente kappa. Foi avaliado o ?ndice de massa corporal (IMC) dos indiv?duos. RESULTADOS: O ap?ndice normal foi identificado em 19 casos por um observador 1 (47,5%) e em 20 casos pelo outro observador (50%). A propor??o de detec??o do ap?ndice ap?s o consenso entre os dois examinadores foi de 47,5% (95% CI 31,5-63,9). O coeficiente kappa entre os observadores na identifica??o do ap?ndice cecal foi muito boa na maioria das seq??ncias analisadas, sendo que a seq??ncia axial T2 FSE apresentou o maior kappa (k: 0.75). T2 FSE sem satura??o de gordura foi a seq??ncia que apresentou maior propor??o de detec??o do ap?ndice normal (47,5%). O ap?ndice foi detectado em uma propor??o maior em crian?as com IMC menor. CONCLUS?O: A RM detectou 47,5% dos ap?ndices normais com uma boa concord?ncia entre os dois examinadores.
|
30 |
Anormalidades na coluna lombar em atletas adolescentes do remoMaurer, Marvin Nessi 16 December 2009 (has links)
Made available in DSpace on 2015-04-14T13:32:42Z (GMT). No. of bitstreams: 1
421227.pdf: 1041426 bytes, checksum: 5571ca9d490194f393fb80fc9fc858c3 (MD5)
Previous issue date: 2009-12-16 / OBJETIVO: o objetivo deste estudo foi avaliar por resson?ncia magn?tica [1] a coluna lombar de atletas adolescentes assintom?ticos praticantes de remo. MATERIAL E M?TODOS: estudo transversal que avaliou 44 indiv?duos adolescentes assintom?ticos do sexo masculino distribu?dos igualmente em dois grupos, 22 remadores e 22 controles. Foi obtido consentimento informado de todos os participantes e de seus respons?veis legais. O estudo foi aprovado pelo Comit? de ?tica em Pesquisa da institui??o. Todos os exames foram realizados em um aparelho de RM de campo aberto de 0.35T e avaliados de maneira cegada por 2 radiologistas capacitados. Foi investigada presen?a de degenera??o/desidrata??o discal, h?rnia ou abaulamento discal, rea??o de estresse do ped?culo e espondil?lise. Foram utilizados o teste t de Student ou teste de Exato de Fisher para os c?lculos estat?sticos. RESULTADOS: No grupo de atletas, 9 (40,9%) apresentaram pelo menos uma altera??o na coluna lombo-sacra pela RM, enquanto que no grupo controle apenas 2 indiv?duos (9,1%) demonstraram pelo menos uma anormalidade (p=0.03). A preval?ncia de rea??o de estresse no ped?culo foi significativamente maior no grupo de atletas, ocorrendo em 5 indiv?duos (22,7%), enquanto que no grupo controle esta anormalidade n?o foi detectada em nenhuma coluna (p=0,048). Com rela??o aos demais achados isolados nosso estudo n?o demonstrou uma diferen?a estatisticamente significativa entre os grupos. CONCLUS?O: A rea??o de estresse do ped?culo ? uma les?o prevalente na coluna lombar de atletas de alto n?vel t?cnico praticantes de remo. A RM mostrou capacidade de detectar les?es precoces na coluna lombar de remadores assintom?ticos.
|
Page generated in 0.0823 seconds