• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 325
  • 8
  • 2
  • Tagged with
  • 342
  • 229
  • 70
  • 68
  • 68
  • 66
  • 52
  • 51
  • 49
  • 34
  • 31
  • 26
  • 23
  • 23
  • 19
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
111

Environmental fate and behavior of mesotrione alone and mixed with S-metolachlor and terbuthylazine in Brazilian soils / Destino ambiental e comportamento do mesotrione isolado e misturado com S-metolachlor e terbuthylazine em solos brasileiros

Kassio Ferreira Mendes 07 April 2017 (has links)
The mixture of herbicides is a widely used technique in weed control in several crops, including maize. However, interactions that might potentially result from mixing herbicides are a matter of constant concern and research. Soils are ideal settings to study transport and behavior of herbicides along gradients of physicochemical properties. The aim of this study was to evaluate sorption-desorption, leaching mineralization, biodegradation, and microbial respiration of mesotrione applied alone and mixed with S-metolachlor + terbuthylazine in samples from Brazilian sites cultivated with maize. The sorption-desorption of 14C-labeled [cyclohexane-2-14C] mesotrione was evaluated using the batch method, leaching was in glass columns, mineralization and degradation experiments were conducted using biometric flask, and microbial respiration was established according to the soil microorganisms: carbon transformation test with 14C-glucose solution in biometric flasks as well. Sorption of mesotrione applied alone and mixed had Kd sorption coefficient) values ranging from 0.08 to 5.05 kg L-1 and from 0.09 to 5.20 kg L-1, respectively, with similar behavior across soils. Mesotrione sorption was influenced primarily by the clay mineral (CM) content and the soil pH. Leaching of mesotrione is relatively high in the tropical soils and correlates with the pH (R2 = -0.84) and CM content (R2 = 0.75) and may pose a potential groundwater contamination risk. From the 49 d laboratory incubation data, increased mineralization half-life of mesotrione were observed for the mixture of herbicides, ranging from a 4 d increase for the sandy loam soil to a 1 d increase in the sandy clay texture soils. Mesotrione degradation rate had a 2-fold increase in the sandy loam compared to the sandy clay soil. Two metabolites can be identified from mesotrione degradation, 4-methyl-sulfonyl-2-nitrobenzoic acid (MNBA) and 2-amino-4-methylsulfonyl benzoic acid (AMBA). For unamended soil - control (without herbicide), microbial activity followed similar behavior to amended soil with herbicides in total 14CO2 released and accumulated, ranging from 23 to 27%. The mode of application of mesotrione did not influence sorption, desorption or leaching. Mesotrione sorption was relatively low in soils, which creates the high potential for leaching in maize producing areas. Thus, recommendations for mesotrione application, without the prior knowledge of the soil physical and chemical properties can result in an inefficient weed control. Mesotrione biotransformation was relatively quick, indicating this herbicide has low persistence, and consequently, low residual effect on crops and weeds when present in similar soils to this present study. Microbial respiration for all treatments was slightly higher in the sandy clay compared with sandy loam soil; although soil samples with application of herbicides (alones and in a mixture) did not have decreased basal microbial respiration or mineralization rate of glucose / A mistura de herbicidas é uma técnica amplamente utilizada no controle de plantas daninhas em diversas culturas, incluindo o milho. No entanto, as interações que podem potencialmente resultar da mistura de herbicidas são uma questão de constante preocupação e pesquisa. Os solos são os locais ideais para estudar o transporte e o comportamento de herbicidas ao longo dos gradientes de propriedades físico-químicas. O objetivo deste estudo foi avaliar a sorção-dessorção, lixiviação, mineralização, biodegradação e respiração microbiana do mesotrione aplicado isolado e misturado com S-metolachlor + terbuthylazine em amostras de locais brasileiros cultivados com milho. A sorção-dessorção do mesotrione 14C-marcado [ciclohexano-2-14C] foi avaliada utilizando o método de lote, a lixiviação foi em colunas de vidro, experimentos de mineralização e de degradação foi realizados utilizando frascos biométricos e a respiração microbiana foi estabelecida de acordo com os microorganismos do solo: teste de transformação de carbono com uma solução de 14C-glicose em frascos biométricos também. A sorção do mesotrione aplicado isolado e misturado apresentou valores de Kd (coeficiente de sorção) varando de 0,08 à 5,05 kg L-1 e de 0,09 à 5,20 kg L-1, respectivamente, com comportamento semelhante nos solos. A sorção do mesotrione foi influenciada principalmente pelo teor de argila mineral (CM) e o pH do solo. A lixiviação do mesotrione é relativamente elevada nos solos tropicais e correlaciona-se com o pH (R2 = -0,84) e teor de CM (R2 = 0,75) e pode representar um potencial risco de contaminação das águas subterrâneas. A partir dos dados de laboratório de 49 dias de incubação, o aumento da meia-vida de mineralização do mesotrione foi observado para a mistura de herbicidas, variando de um aumento de 4 dias do solo franco-arenoso para um aumento de 1 dia nos solos de textura argilo-arenosa. A taxa de degradação do mesotrione apresentou um aumento de 2 vezes no franco-arenoso em relação ao solo de textura argilo-arenosa. Dois metabólitos podem ser identificados a partir de degradação do mesotrione, o ácido 4-metil-sulfonil-2-nitrobenzóico (MNBA) e 2-amino-4-metilsulfonil benzóico (AMBA). Para o solo sem alterações - controle (sem aplicação de herbicida), a atividade microbiana seguiu comportamento similar ao solo tratado com herbicidas no total de 14CO2 liberado e acumulado, variando de 23 a 27%. O modo de aplicação do mesotrione não influenciou a sorção, dessorção ou lixiviação. A sorção do mesotrione foi relativamente baixa nos solos, que gera alto potencial de lixiviação em áreas produtoras de milho. Assim, as recomendações para a aplicação do mesotrione, sem o conhecimento prévio das propriedades físicas e químicas do solo podem resultar em um ineficiente controle de plantas daninhas. A biotransformação do mesotrione foi relativamente rápida, indicando que este herbicida tem baixa persistência, e, consequentemente, baixo efeito residual sobre as culturas e plantas daninhas, quando presentes em solos semelhantes ao presente estudo. A respiração microbiana em todos os tratamentos foi ligeiramente superior no argilo-arenoso em comparação com o solo franco-arenoso; embora as amostras de solo com aplicação de herbicidas (isolados e em uma mistura) não têm diminuído a respiração microbiana basal ou a taxa de mineralização da glicose
112

Efeito do pino intra-radicular e da presença de férula na resistência de dentes tratados endodonticamente / Effect of intraradicular post and the presence of ferrule on the resistance of endodontically treated teeth

Jefferson Ricardo Pereira 06 August 2007 (has links)
O objetivo deste trabalho foi avaliar a resistência à fratura de dentes tratados endodonticamente restaurados com diferentes pinos intra-radiculares, sem pinos intra-radiculares e diferentes quantidades de remanescente dentário coronal. Para a realização deste trabalho, foram selecionados 60 caninos humanos recentemente extraídos. Todos os dentes foram tratados endodonticamente e divididos aleatoriamente em 6 grupos de 10 dentes cada. Grupos NMF0 e NMF3 (grupos controle): dentes restaurados com núcleos metálicos fundidos com 0mm (sem férula) e 3mm de estrutura coronal, respectivamente; Grupos PF0 e PF3: dentes restaurados com pinos pré-fabricados (Screw Post) com 0mm e 3mm de estrutura coronal, respectivamente; e Grupos RC0 e RC3: dentes restaurados com resina composta com 0mm e 3mm de estrutura coronal, respectivamente. Os grupos restaurados com pinos pré-fabricados ou resina composta receberam núcleos de preenchimento de resina composta (Z250) localizados acima das diferentes alturas de remanescente coronal. Todos os dentes foram restaurados com coroas totais metálicas. A resistência à fratura (kgf) foi medida em uma máquina de ensaio universal à 45 graus ao longo eixo do dente até a falha do conjunto. Os dados foram analisados através da Análise de Variância (ANOVA) a dois critérios, e o teste de Tukey (\'alfa\'=.05). A ANOVA (\'alfa\'=.05) mostrou haver diferenças estatisticamente significativas entre os tipos de pinos (P<.000), entre as diferentes alturas de remanescente coronal (P<.000) e mostrou uma significativa inter-relação entre os tipos de pinos e remanescente coronal (P<.000). No entanto, quando as forças médias de resistência à fratura foram comparadas (grupo NMF0 - 820.20N, grupo NMF3 - 1179.12N, grupo PF0 - 561.05N, grupo PF3 - 906.79N, grupo RC0 - 297.84N e grupo RC3 - 1135.15N) não foram detectadas diferenças significativas entre os 3 grupos com 3mm de remanescente coronal (grupos NMF3, RC3 e PF3). Os resultados deste trabalho mostraram que a presença de férula providencia um significativo aumento da resistência à fratura de dentes tratados endodonticamente restaurados com núcleos metálicos fundidos, pinos pré-fabricados ou resina composta, e mostraram que a presença de um pino intra-radicular para restaurar dentes tratados endodonticamente é necessária quando não existe remanescente dentário coronal (efeito férula). / The aim of this study was to investigated the fracture resistance of endodontically-treated teeth restored with different posts, without post and variable ferrule heights. Sixty freshly-extracted canines were endodontically treated. They were randomly divided into groups of 10 teeth and were prepared according to 6 experimental protocols. CP0 group and CP3 group (control groups): teeth restored with custom cast post-and-core with 0 mm (no ferrule) and 3 mm of coronal structure, respectively; PF0 group and PF3 group: teeth restored with prefabricated post (Screw-Post) with 0 mm and 3 mm of coronal structure, respectively; and CR0 group and CR3 group: teeth restored with composite resin with 0 mm and 3mm of coronal structure, respectively. The groups restored with prefabricated post or composite resin received composite resin core (Z250) located superior to the different tooth structure heights. All teeth were restored with complete metal crowns. The fracture resistance (N) was measured in a universal testing machine at 45 degrees to the long-axis of the tooth until failure. Data were analyzed by 2-way analysis of variance and Tukey test (\'alpha\'=.05). The 2-way analysis of variance (\'alpha\'=.05) showed difference statistically significant among the types of post (P<.000), between the different coronal dentin heights (P<.000) and showed a highly significant interaction among type of post and coronal remaining (P<.000). However, when the means fracture forces for the groups were compared (CP0 group - 820.20N, CP3 group - 1179.12N, PF0 group - 561.05N, PF3 group - 906.79N, CR0 group - 297.84N, and CR3 group - 1135.15N) no significant differences could be detected among the three groups with 3 mm of coronal remaining (CP3, CR3 and PF3 groups). The results of this study showed that larger ferrule designs in crowns provided a significantly higher fracture resistance of endodontically-treated teeth restored with custom cast post and core, prefabricated posts, or composite resin and showed that the presence of the post to restore endodontically-treated teeth is necessary when there is not a crown ferrule effect.
113

Efeito da espessura da camada de cimento na integridade e resistência adesiva de pinos de resina reforçados por fibra de vidro / Effect of the thickness of the resin cement on the bond integrity and strength of glass fiber fiber-reinforced composite post

Katia Rodrigues Reis 05 June 2009 (has links)
A perda de adesao e uma falha comum reportada para os pinos reforçados por fibra e usualmente ocorre ao longo da interface adesiva entre a dentina radicular e o cimento resinoso. A espessura de cimento resinoso ideal para preservar a continuidade da interface adesiva cimento-dentina e aumentar a retencao do pino e desconhecida. O objetivo deste estudo foi avaliar a influencia da espessura do cimento na integridade e na resistencia adesiva de dois cimentos resinosos empregados para a cimentacao de pinos reforcados por fibra. Trinta incisivos laterais superiores humanos com comprimentos radiculares semelhantes foram selecionados, secionados na juncao cimento-esmalte e tratados endodonticamente. As raizes foram aleatoriamente divididas em seis grupos (n=5), e os condutos radiculares foram preparados a uma profundidade de 8 mm usando uma das três brocas com diametro diferente: Broca Largo n 3 para o grupo controle (L3 1 mm); Broca Largo n&#8501; 4 (L4 - 1,25 mm) e Broca Largo n&#8501; 5 (L5 1,5 mm) para os grupos experimentais. Pinos de resina reforcados por fibra de vidro (Fibrekor post, Jeneric Pentron), 1 mm de diametro, foram cimentados aos condutos radiculares utilizando o cimento resinoso dual (Duolink, Bisco) ou o cimento resinoso autopolimerizavel (C&B Cement, Bisco). A porcao de cada especime contendo os pinos reforcados por fibra foi secionada transversalmente em tres secoes (cervical, media e apical) de 2 mm de espessura utilizando um disco diamantado em maquina de corte seriado sob refrigeracao com agua. As secoes foram polidas, limpas ultrassonicamente e duplicadas com polivinil siloxano. Replicas em resina epoxica das secoes foram obtidas para a mensuracao da espessura do cimento e da integridade adesiva na interface cimento-dentina por meio de MEV. As secoes foram armazenadas em solucao fisiologica a 37o C por uma semana e, entao, submetidas ao teste push-out em uma maquina de ensaio universal a velocidade de 0,5 mm/min-1, e a forca maxima requerida para deslocar cada pino foi registrada (N). Os dados foram analisados usando ANOVA a um criterio, teste de Tukey e teste t de Student (&#945;=0,05). A correlacao entre a integridade adesiva, a resistencia adesiva e a espessura do cimento tambem foi determinada pelo coeficiente de Pearson (&#945;=0,05). A comparacao multipla entre as condicoes experimentais para cada cimento revelou que os valores medios de integridade adesiva (%) e de resistencia adesiva (MPa) dos pinos reforcados por fibra cimentados com o cimento resinoso Duolink foram significantemente maiores no grupo controle (L3: 61,79 ± 18,06 e 11,32 ± 4,66) do que no grupo experimental com camada de cimento muito espessa (L5: 38,91 ± 5,75 e 4,68 ± 2,16) (p=0,018 e p=0,035), respectivamente. Embora nao tenha sido observada diferenca significante na integridade adesiva entre as diferentes espessuras de cimento avaliadas para o cimento resinoso C&B Cement (p>0,05), o grupo com camada de cimento muito espessa (L5: 10,67 ± 4,59) foi significantemente mais retentivo do que o grupo controle (L3: 4,01 ± 0,76) (p=0,014). A comparacao entre cimentos para cada condicao experimental mostrou que o cimento resinoso Duolink foi mais retentivo do que o cimento resinoso C&B Cement no grupo controle (11,32 ± 4,66 e 4,01 ± 0,76, p=0,008), ao passo que o cimento resinoso C&B Cement foi mais retentivo do que o cimento resinoso Duolink em L5 (4,68 ± 2,19 e 10,67 ± 4,59, p=0,030), respectivamente. Somente a comparação entre o grupo experimental L4 e os outros grupos nao foi significante para ambos os cimentos resinosos e testes realizados. O aumento da espessura do cimento diminuiu significantemente a integridade adesiva (r=-0,5901; p=0,021) e a resistência adesiva (r=-0,5387; p=0,038) para o cimento resinoso Duolink. A integridade adesiva correlacionou-se positivamente com a resistencia adesiva para esse tipo de cimento resinoso (r=0,6855; p=0,005). Diferentemente, nao foi encontrada correlação significante entre a espessura do cimento e a integridade adesiva (r=0,153; p=0,586) e nem entre a integridade adesiva e a resistencia adesiva (r=0,2969; p=0,283) registradas para C&B Cement. Contudo, o aumento da espessura deste tipo de cimento resinoso aumentou significantemente a retencao do pino (r=0,6576; p=0,008). Os dados sugeriram que a espessura da camada dos cimentos resinosos influenciou a integridade adesiva e a resistencia adesiva dos pinos de resina reforcados por fibra. Para o cimento resinoso Duolink selecionado, os maiores valores de integridade adesiva e de resistencia adesiva foram obtidos quando a camada mais fina de cimento foi testada (L3). Contudo, o cimento resinoso C&B Cement apresentou maior retencao quando a espessura da camada de cimento aumentou muito (L5), embora a espessura do cimento nao tenha desempenhado um papel importante na integridade adesiva da interface cimento-dentina para esse cimento resinoso. / Debonding is the most common cause of failure reported for glass fiberreinforced composite posts and occurs frequently along the adhesive interface between the resin cement and the root dentin. The ideal thickness of the resin cement to preserve the continuity along the cement-dentin interface and to increase the retention of the post is unknown. The purpose of this study was to evaluate the influence of the thickness of the resin cement on the bond integrity and strength of two resin cements used for glass fiber-reinforced composite posts cementation. 30 human maxillary incisors with similar root dimensions were selected, sectioned at the amelocemental junction and endodontically treated. The roots were randomly divided into six groups (n=5), and the post spaces were prepared 8 mm deep using one of the three burs with different diameters: Largo bur n&#8501; 3 for the control group (L3 1- mm); Largo bur n&#8501; 4 (L4 1,25-mm) e Largo bur n&#8501; 5 (L5 1,5-mm) for the experimental groups. Fiber-reinforced composite posts (Fibrekor post, Jeneric Pentron), 1-mm diameter, were cemented to post spaces by using the dual-cure (Duolink, Bisco) or self-cure system (C&B Cement, Bisco). The portion of each specimen that contained the bonded fiber post was sectioned into three 2-mm thick serial slices (cervical, middle, apical) with the Isomet saw under water cooling. The slices were polished and ultrasonicated in deionized water. Polyvinyl siloxane impressions of the observable surfaces were taken and the surfaces replicated with epoxy resin for measuring of the thickness of the resin cement and the bond integrity by using MEV. The slices were stored in physiologic solution at 37o C for one week, and then submitted to the push-out test at a crosshead speed of 0.5 mm/min-1. The maximum force required to dislocate each post was registered (N). Data were analyzed by one-way ANOVA, Tukey test and t test (&#945;=0,05). The correlation between bond integrity, bond strength and thickness of the resin cement was also determined by correlation test (&#945;=0,05). The multiple comparison test between the experimental conditions for each resin cement showed that the mean values of bond integrity (%) and strength (MPa) of the fiber posts cemented with Duolink were significantly higher at the control group (L3: 61.79 ± 18.06 and 11.32 ± 4.66) than those obtained for the experimental groups with the thicker layer cement (L5: 38.91 ± 5.75 and 4.68 ± 2.16) (p=0.018 and p=0.035), respectively. Although there was no significant difference on the bond integrity between the different thicknesses evaluated for C&B Cement (p>0.05), the group with thicker layer (L5: 10.67 ± 4.59) was significantly more retentive than the control group (L3: 4.01 ± 0.76) (p=0.014). The comparison between cements for each experimental condition has showed that Duolink was more retentive than C&B Cement at the control group (11.32 ± 4,66 and 4.01 ± 0,76, p=0.008), whereas C&B Cement was more retentive than Duolink at L5 group (4.68 ± 2.19 and 10.67 ± 4.59, p=0.030), respectively. Only the comparison between the L4 experimental group and the others groups was not significant for both resin cements and tests conducted. The increase of the thickness of the cement significantly reduced the bond integrity (r=-0.5901; p=0.021) and strength (r=-0,5387; p=0.038) for Duolink. Bond integrity positively correlated with bond strength for this type of resin cement (r=0.6855; p=0.005). On the other hand, there was no significant correlation between the thickness of the cement and the bond integrity (r=0.153; p=0.586) and neither between the bond integrity and strength (r=0.2969; p=0.283) registered for C&B Cement. However, the increase of the thickness of this type of resin cement has significantly increased the retention of the post (r=0.6576; p=0.008). Data suggested that the thickness of resin cements affected both the bond integrity and strength of fiber posts. For the Duolink resin cement selected, the higher values of bond integrity and strength were obtained when the thinner layer was tested (L3). However, C&B Cement has showed higher retention when the thickness of the cement increased excessively (L5), though the thickness of the cement has not played a role on the bond integrity of the cement-dentin interface for this resin cement.
114

"Avaliação da retenção de prótese total bimaxilar em função das características da área basal" / Evaluation of the retention of bimaxillay complete denture in function of the characteristics of the basal area.

Eudes Francisco da Silva Cunha 28 January 2005 (has links)
Nesta pesquisa, em 14 pacientes da Clínica de Prótese Total da Faculdade de Odontologia da Universidade de São Paulo, foi realizada a avaliação da retenção de prótese total bimaxilar em função das características da área basal por três avaliadores clínicos experientes e calibrados. Foram avaliadas as retenções vertical anterior, laterais direita e esquerda e póstero-anterior e as características da área basal: forma, tamanho, altura e tipo do rebordo e a consistência da fibromucosa. Por se tratarem de opiniões, os dados foram transformados em escores e submetidos à análise de variância não paramétrica com o teste KRUSKAL-WALLIS e paramétrica com o teste ANOVA. Concluiu-se que, na maxila, a retenção das próteses totais novas foi influenciada positivamente pelo tipo rebordo paralelo e pela consistência resiliente da fibromucosa, enquanto na mandíbula influenciaram o tamanho médio e a forma oval. As opiniões sobre a retenção e o grau de satisfação entre os avaliadores e os pacientes foram as mesmas. / In this research, a evaluation of the retention of bimaxilar complete denture in function of the characteristics of the basal area by three calibrated experienced clinician was accomplished in 14 patients of the Odontology College of the University of São Paulo. The anterior vertical retention, right lateral retention, left lateral retention, posteroanterior retention and rigde shape, ridge size, rigde height, ridge type and the fibromucosa consistency were evaluated. Because of they are opinions, the data were trans formed in scores and submitted to the no parametric variance analysis with the KRUSKAL-WALLIS and ANOVA parametric tests. Conclusion, in the maxilla, the retention of the new complete denture, was positively influenced by the parallel rigde type and by the resilient consistency of the fibromucosa, while in the mandible, the decisive factors of the retention were the medium size of the rigde and the oval shape of this. The opinions about the retention and the level of satisfaction had been the same among the appraisers and patients.
115

"Análise comparativa entre sistemas de retenção para próteses auriculares implanto-retidas" / Comparative analyses between retentive systems for implant-retained ear prosthesis

Andréa Alves de Sousa 03 May 2006 (has links)
As próteses auriculares retidas por meio de implantes osseointegráveis proporcionam maior segurança e conforto, melhorando a qualidade de vida dos pacientes. Este trabalho avalia comparativamente a força de resistência à tração dos sistemas de retenção barra/2 clipes, barra/3 clipes, 2 magnetos, e 3 magnetos, empregados para retenção de prótese auricular. Os sistemas de retenção foram submetidos à ciclagem mecânica, com intervalos de 540 ciclos de inserção e remoção para a simulação de períodos de uso clínico, até um total de 3240 ciclos, sendo, a cada intervalo, submetidos ao ensaio mecânico para força de resistência à tração. Os resultados indicam que os sistemas barra/clipes proporcionam maiores retenções do que os sistemas com magnetos e ao mesmo tempo em que a ciclagem mecânica não interfere na relação entre o número de elementos retentores e a retenção proporcionada dentro dos sistemas barra/clip e dos sistemas magnetos. O sistema barra/2 clipes sofre uma perda significantemente maior da capacidade de retenção frente à ciclagem mecânica, sugerindo uma menor longevidade clínica. A relação da capacidade de retenção entre os sistemas não se altera com a ciclagem mecânica uma vez que, a retenção proporcionada pelo sistema barra/3 clipes mantém-se superior, indicando uma maior durabilidade clínica. As retenções proporcionadas pelos sistemas barra/2 clipes e 3 magnetos, bem como aquelas proporcionadas pelos sistemas 2 e 3 magnetos não diferem ao final da ciclagem mecânica, indicando uma durabilidade clínica semelhante. / Placement of osseointegrated implants for retention of ear prosthesis provides greater security and comfort, improving the quality of life of the patients. This work evaluates and compares the retentive mechanical behavior of bar/2 clips, bar/3 clips, 2 magnets, and 3 magnets retention systems, used for implant-retained ear prosthesis. The systems were submitted to mechanical cycling , with intervals of 540 cycles of insertion and removal, for the simulation of clinical periods of function, up to 3240 cycles, being submitted to the mechanical forces essay at each interval. Data were subjected to Tukey-Kramer procedure and the comparative analyses indicate that the bar/clips systems provide different and better retentive forces than the magnet systems and mechanical cycling does not alter the numerical relative performance of the retainer components within the bar/clip or magnet retention system. The bar/2 clips system shows the biggest and statistically significant loss of the retentive forces during mechanical cycling (p<0,05), suggesting a shorter clinical life. The retention provided by the bar/3 clips system remains superior after mechanical cycling, indicating a longer clinical life. The relation between the retention forces presented within the bar/clip systems and magnets systems does change under mechanical cycling. Also, the relation between the bar/2 clips system and 3 magnets system, as well as between 2 and 3 magnets systems do not differ at the end of mechanical cycling , indicating a similar behavior toward clinical life.
116

Desenvolvimento de formulções tópicas contendo extrato de própolis verde: estudos de estabilidade, liberação, permeação e retenção cutânea / Development of topical formulations containing green propolis extract: stability, release, permeation and retention studies

Yris Maria Fonseca 26 March 2007 (has links)
Tem sido reportado que os danos UV induzidos são devidos principalmente pela geração de EROs. Assim, compostos capazes de inibir a ação e a formação destas EROs, serão capazes de proteger a pele dos danos UV induzidos. Devido suas propriedades, a própolis pode ser aplicada como antioxidante tópico para prevenir e/ou tratar os danos UV induzidos. Desta forma, o objetivo deste trabalho foi avaliar o conteúdo de flavonóides e polifenóis e a atividade antioxidante, em diferentes sistemas ?in vitro?, dos extratos fluido e seco de própolis brasileira verde. Em adição, formulações tópicas adicionadas com extrato fluido de própolis verde foram desenvolvidas e sua estabilidade física e funcional foi avaliada. Foram também avaliadas a capacidade de liberação, permeação e retenção dos compostos antioxidantes destas formulações. O conteúdo de flavonóides e polifenóis encontrado para ambos extratos foi de 2,29 mg/g e 18 mg/g, respectivamente. Foi observado que o extrato de própolis verde apresentou a mesma quantidade de polifenóis que outros extratos de própolis já estudados, entretanto apresentou menor quantidade de flavonóides. Este extrato demonstrou ainda, atividade antioxidante de forma dose dependente contra diferentes radicais, tais como DPPH?, superóxido (O2-), hidroxila (OH?), peroxila (LOO?) e alkoxila (LO?). E ainda, as formulações desenvolvidas foram estáveis fisicamente e funcionalmente. A F 01 foi capaz de liberar seus compostos antioxidantes mais eficazmente que as outras formulações desenvolvidas. Entretanto, somente a F 03 reteve seus compostos antioxidantes na epiderme viável. Estes resultados dão boas perspectivas para aplicar o extrato de própolis verde topicamente para prevenir e/ou tratar os danos UV induzidos na pele. Em adição, pode ser sugerido que F 03 pode ser aplicada topicamente para prevenir e/ou tratar o estresse oxidativo UV induzido na pele com probabilidade de sucesso. / It has been reported that UV- induced damage is due mainly to the generation of ROS. Then, compounds able to inhibit the action and the formation of these ROS, will be able to protect the skin from UV-induced damage. Due to their properties, propolis can be applied as topical antioxidants to prevent and/or treat UV-induced damages. Thus, the purpose of this work was to evaluate the polyphenol and flavonoid contents and the antioxidant activity, in different ?in vitro? systems, of the Brazilian green propolis fluid and dry extracts. In addition, topical formulations added with green propolis fluid extract were developed and their physicalchemical and functional stabilities were assessed. It was also evaluated the release, permeation and skin retention capacity of the antioxidant compounds from these formulations. The flavonoid and polyphenols contents found for both extracts were 2.29 mg/g and 18 mg/g, respectively. It was observed that green propolis extract showed the same amount of polyphenols as other propolis extracts which has already been studied, however showed lower amounts of flavonoids. This extract also showed antioxidant activity in a dose dependent manner against different radicals, such as DPPH?, superoxide (O2-), hydroxyl (OH?), alkoxyl (LO?) and peroxyl radicals. Furthermore, the formulations developed were physically and functionally stable. F 01 was able to release its antioxidant compounds in more efficient way than the other developed formulations. However, only F 03 retained its antioxidant compounds on viable epidermis. These results give good perspectives to apply green propolis extract topically in order to prevent and/or treat UV-damaged skin. In addition, it may be suggested that F 03 could be topically applied to prevent and/or treat UV- induced oxidative stress on skin with probability of success.
117

Desenvolvimento de equipamento de teste de estruturas miniaturizadas: testes em estrutura útil na eliminação de partículas. / Development of machine to test miniaturized structures: tests in util structure from particles elimination.

Leandro Colevati dos Santos 26 May 2006 (has links)
Amostras com pequenos volumes e matrizes complexas, como sistemas biológicos, necessitam de preparação criteriosa. Muitas dessas amostras são melhor analizadas em estruturas miniaturizadas devido à necessidade de detectar células e microorganismos em diferentes matrizes. Por essa razão, equipamentos capazes de detectar e destruir microorganismos e estruturas para prévia retenção desses se faz necessários na vida moderna. Chicanas, constrições usadas para reduzir velocidade de fluxo, que podem ser utilizadas para reter compostos, são estruturas macroscópicas para remover resíduos de lagos, fazendas e etc. e chicanas miniaturizadas foram usadas para a adsorção de compostos orgânicos do ar e da água. Assim, esse trabalho tem dois diferentes objetivos: 1) Produção de um equipamento de baixo custo, para teste de partículas ou eliminação de microorganismos e 2) O desenvolvimento de estruturas miniaturizadas para retenção e/ou seleção de partículas e substâncias viscosas de um fluido líquido. A metodologia utilizada foi: 1) Dois software foram escolhidos para esse trabalho. O LabVIEW® 7.0 foi utilizado como plataforma para o desenvolvimento do software do equipamento e o FemLAB® 3.1 para a simulação de estruturas. O equipamento produzido usou Microbalança de Quartzo como detector e um sistema de admissão baseado em uma bomba e tubos. 2) O desenho da estrutura foi otimizado por simulação do comportamento do fluxo. A estrutura otimizada foi feita desmontável, e usinada em polimetilmetacrilato ? acrílico, com ferramentas convencionais. Acrílico foi usado devido à sua transparência óptica, que permite testes com microsocpia óptica. As simulações consideraram N2 e Água como fluidos gasoso e líquido, respectivamente. Avaliou-se o comportamento das partículas (50?m and 13?m) em fluxo gasoso e polidimetilsiloxano (silicone, com viscosidade de 350 cSt) e partículas em fluxo líquido. As estruturas foram caracterizadas quanto à adsorção e retenção de partículas usando equipamento desenvolvido e por microscopia óptica. As estruturas foram, também, continuamente fotografadas durante a execução do experimento e fotos foram utilizadas para determinar o comportamento do fluxo. Os reagentes foram injetados na estrutura em pequenos pulsos. O equipamento mostrou boa performance para detecção de adsorção em fluxo líquido e reprodutibilidade no monitoramento do aquecimento de estruturas. As chicanas mostraram boa capacidade de reter partículas grandes (50?m), mas não pequenas (13?m), tanto para fluxos gasosos como líquidos. Contudo, a estrutura tem pequena capacidade de carga para fluidos líquidos (? 1mg); além disso, a retenção de amostras de silicone na estrutura, utilizando fluido líquido, ocorreu devido à diferença de velocidade entre os fluidos. A simulação e os resultados experimentais apresentam boa correlação. Assim, a chicana mostrou a possibilidade de, seletivamente, separar partículas em fluxos gasosos e líquidos ou reter substâncias viscosas em fluxo líquido. Esses resultados apontam para diversas aplicações, como por exemplo, pré-tratamento para análises biológicas e retenção ou eliminação de microorganismos. / Samples with small volume and complex matrix, such as biological systems, require careful preparation. Many of these samples are better analyzed in miniaturized structures owing to the need of detect cells and microorganisms in different arrays. Therefore equipment able to detect and destroy microorganisms and structures to previously retain them are require in the modern life. Chicanes, i.e. constrictions used to reduce flow velocity, can be useful to retain compounds, are macroscopic devices to remove waste removal from lakes, farms, etc. and miniaturized chicane was used to adsorption of organic compounds from air and water. Thus, this work has two different targets: 1) Production of a low-cost equipment useful for tests of particle or microorganisms elimination and 2) The development of miniaturized structures useful for retention and/or selection of particles and viscous substances from a liquid flow. The methodology used was: 1) Two software were chosen to this work. The LabVIEW® 7.0 was used for development of equipment software and FemLAB® 3.1 for structures simulation. The equipment production used Quartz Crystal Microbalance as detector and an admission system based on simple pumps and plumbing. 2) The design of the structure design was optimized using flow simulation. The optimized design was manufactured in poly(methyl methacrylate) -acrylic, with conventional tools. Acrylic was used due to the optical transparency that allows photographic tests and the structures can be easily disassembled. The simulations considered nitrogen and water for gaseous and liquid flow, respectively. It was evaluated the behavior of particles (50?m and 13?m) on gaseous flow and polydimethylsiloxane (silicone, viscosity of 350 cSt) and particles on liquid flow. The structures were characterized using equipment produced to measure adsorption and optical microscopy to evaluate particle retention. The structures were also continuously photographed during the experiments and the photos were analyzed to determine flow behavior. The reactants were inserted in the structure in small pulses. The equipment shows good performance for detection of adsorption in liquid flows and reproducibility on monitoring heated structures. Chicanes showed good ability to retain big particles (50 ?m) but not small ones (13 ?m) for both liquid and gaseous flow. However, the structure has small load capacity for liquids (? 1 mg). Moreover, the retention of silicone samples in the structure on liquid flow occurs due to the difference in the fluid velocity. The simulation and experimental results are in good agreement and also chicane structure shows the possibility of selectively separate particles from gaseous and liquid flow or retain viscous substances from a liquid flow. These results point out to several applications, such as sample pretreatment for biological analysis and microorganism retention or elimination.
118

Retenção de clientes à luz do gerenciamento de churn : um estudo no setor de telecomunicações / Costumer retention in the light of churn management : a study in the telecommunication sector

Patrícia Regina Caldeira Daré Artoni 30 August 2007 (has links)
O aumento da competição global tem aumentado os custos associados à atração de novos consumidores, impondo às empresas o desafio de mudar sua forma de atuação perante seus exigentes consumidores a fim de mantê-los. Diante desse desafio, este trabalho visa aprofundar o estudo do relacionamento entre a empresa e o cliente, identificando em que consiste o gerenciamento de churn e seu papel para a melhoria de ações de marketing para reter clientes. No intuito de alcançar o objetivo proposto, realizou-se uma pesquisa bibliográfica sobre o assunto, seguida de uma pesquisa de campo com abordagem qualitativa do tipo exploratória a partir de estudos de casos múltiplos em organizações de serviços do setor de telecomunicações no Brasil. A pesquisa de campo foi norteada pelo protocolo que abordou, entre outros pontos, os critérios de escolha dos casos, o roteiro de entrevistas e a forma de análise dos dados coletados. A escolha do setor foi motivada tanto por sua representatividade em nível nacional e internacional, quanto pelas mudanças que vem enfrentando na sua estrutura de competição, principalmente após os processos de privatização. Além disso, a indústria de telecomunicações é especialmente rica para este estudo, visto que suas empresas estão especialmente voltadas ao gerenciamento do churn. Os resultados obtidos ajudaram a compreender o processo de gerenciamento de churn, como este está inserido na gestão das empresas e suas aplicações. Nota-se seu papel no auxilio à identificação dos consumidores mais propensos a abandonar a empresa, assim como daqueles que ela deseja atrair e reter para ser capaz de desenvolver práticas eficientes e lucrativas. As limitações deste trabalho são fundamentalmente associadas à metodologia da pesquisa de campo. Além disso, colocam-se como possibilidades para desdobramentos futuros a condução de pesquisas quantitativas que visem testar, mensurar e avaliar os resultados do gerenciamento e pesquisas para compreender o impacto ambiental em suas práticas e resultados. / The rise in global competition has increased costs related to attracting new consumers, bringing companies the challenge of changing their behavior towards their ever more demanding clients in order to keep them. To assist in this challenge, this paper aims to deepen the studies regarding the company and the client, identifying what is considered churn management and its role to improve marketing actions to capture clients. With the aim of achieving the proposed goal, a bibliographic research was conducted as well as a qualitative field research in the exploratory type, which through multiple case studies, in organizations of the telecommunications sector, within Brazilian context. The field research was directed by a protocol and approached the criteria to choose the cases to be studied, the interviewing script and the form of analysis of the information gathered. The choice for this sector was driven for its national and international representation as well as for the changes the sector has been undergoing especially after its privatization. Moreover, the sector is specially recommended for the study as its companies are especially concerned with churn management. The obtained results helped understand the churn management process and how this is input in business administration and its applications. We can note its role in helping to identify consumers who are more likely to abandon the company and to identify the consumers the company wishes to attract and capture to be able to develop the necessary actions. The limitations of this paper are relative to the methodology of the field research. Besides this, conducting quantitative research which aims to test, measure and evaluate the results of management as well as to comprehend the environmental impact, the business model in practice and its results is considered for future studies.
119

Curva de retenção de água no solo determinada a partir de um número mínimo de pares de umidade e tensão na câmara de Richards / Soil water retention curve determined by a minimum number of water content and water potential pairs in Richards\' chamber

Gilmar Batista Grigolon 27 November 2012 (has links)
O conhecimento do comportamento físico-hídrico do solo é fundamental para sua caracterização. Dentre elas, a determinação da curva de retenção de água é o processo que costuma ser mais oneroso e demorado. Várias tentativas estão sendo estudadas no sentido de minimizar custo e tempo para a obtenção desta curva. A escolha do número e da combinação de pontos, ou seja, dados de umidade e correspondente tensão da água no solo, utilizados para a determinação da curva de retenção, normalmente é feita de forma arbitrária, contudo, a demora na obtenção da curva de retenção, aliada ao valor considerado alto para pequenos irrigantes, são na maioria das vezes, um empecilho para que o agricultor realize esta análise. O objetivo deste trabalho foi definir o menor número e a melhor combinação de pares de umidade e tensão de água no solo que resulte na descrição de uma curva de retenção de água do solo confiável. Para a realização da pesquisa, foram utilizados dois tipos de solos com granulometrias distintas, (arenoso e argiloso). Foram realizadas nove repetições, para cada tipo de solo, as quais foram submetidas a diferentes tensões pelo método da câmara de Richards e ajustadas pelo modelo de van Genuchten. Realizaram-se curvas contendo 4, 5, 7, 8, 9, 10 e 13 pontos de tensão, sendo que a curva que contem 13 pontos foi adotada neste estudo como referência (A1) na comparação com as demais. A análise estatística foi gerada inicialmente sobre os dados brutos das umidades do solo observadas para todas as repetições, calculando-se os coeficientes de variação para os parâmetros do modelo de van Genuchten. Posteriormente, entre os dados observados e ajustados pelo modelo, foram determinados índices estatísticos comparativos. Finalmente, os parâmetros obtidos de vários pares de umidade e correspondente tensão de água no solo obtidos na câmara Richards foram comparados aos parâmetros equivalentes da curva referência (A1) e submetidos à análise de variância (teste F), e suas médias comparadas pelo teste de Scott-Knott a 5%. A curva de retenção de água no solo com 7 pontos, elaborada com as tensões 0, 40, 100, 300, 1.000, 5.000 e 15.000 hPa, foi a que mais se aproximou da curva de referência A1, não apresentando diferença estatística em nenhum dos parâmetros do modelo. / The knowledge of the soil hydrophysical behavior is critical for characterizing its physical properties. Among them, the determination of the soil water retention curve is often the most expensive and the most time consuming. Many attempts have been tried in order to minimize the cost and the time to obtain this curve. The choice of number and combinations of points to be taken, i.e., water content and its corresponding water potential in soil, used to determine the soil water retention curve, is usually made arbitrarily, however, the delay in obtaining the curve, coupled with the cost considered high to small irrigators, are mostly an obstacle for the farmer to carry out this analysis. The objective of this work was to define the smallest number and the optimal combination of water content and water potential pairs that result in a trustable soil water retention curve. To carry out this research, two types of soils with contrasting textures were used (sandy and clay soil). For each type of soil, nine repetitions were submitted to different tensions by the Richards chamber method and adjusted by the equation of van Genuchten. Curves with 4, 5, 7, 8, 9, 10 e 13 tension points were made, taking the 13-point curve as a standard (A1) in comparison to the others. Initially, the statistical analysis was performed on the raw data of the observed water contents for all the repetitions, calculating the variation coefficient for the van Genuchten equation parameters. Subsequently, statistical indices of comparison were used between the observed and adjusted data. Lastly, the obtained parameters for different pairs of water content and its corresponding water potential in Richards\' chamber were compared to the equivalent parameters of the standard curve (A1) and submitted to the analysis of variance (F test), and their mean values were compared by the Scott-Knott test (5% of probability). The 7-point soil water retention curve, using the tensions of 0; 40; 100; 300; 1,000; 5,000 e 15,000 hPa, was the closest one to the standard curve A1, showing no statistical difference in any parameters of the model.
120

Treinamento virtual: é possível aprender por meio de jogos? Aprendizado e retenção em indivíduos com sequelas crônicas de acidente vascular encefálico / Not informed by the author

Danielle Borrego Perez 29 November 2016 (has links)
O processo de aprendizagem motora (AM) envolve a reorganização de redes neurais mediadas pelo treino a qual permite um aprimoramento do desempenho na tarefa treinada. O sucesso da reabilitação de pacientes com lesões nervosas é intimamente dependente do potencial do treinamento aplicado de ativar e potencializar o processo de AM. A sequela motora mais limitante e refratária a reabilitação em pacientes vitimas de Acidente Vascular Encefálico (AVE), é a paresia do membro superior contralateral ao hemisfério lesado. Diante disso, a busca por novas estratégias de treino que potencializem o processo de AM têm sido uma constante na área. O treinamento em realidade virtual (RV) é uma nova promessa nesse sentido, pois poderia oferecer condições favoráveis para AM. A despeito do crescimento do uso desse tipo de ferramenta para reabilitação do membro superior parético (MSP) em pacientes com AVE, ainda não há evidencias consistentes sobre seu potencial para promover AM. Assim, o objetivo deste estudo foi investigar a melhora do desempenho de curta e longa duração após um treinamento para membros superiores (MS) em RV, baseado em jogos do Nintendo Wii® (NW), em indivíduos portadores de sequelas crônicas de AVE. Para alcançar esse objetivo, o desempenho de 22 indivíduos com sequelas crônicas de AVE em MS, 17 homens e 5 mulheres com média de idade 52.7±10.29 e média de 5.68±5.31 anos pós AVE foi registrado em quatro jogos do NW que demandam movimentos de MS com amplitude e velocidade variáveis e foram comparados antes e depois do treino. A aquisição intrasessão foi obtida por meio da comparação da pontuação nos jogos antes do treinamento (AT) e imediatamente após o treino (IDT), enquanto a retenção de curta duração foi obtida pela comparação entre a avaliação IDT e 48 horas após o treino (48hDT), e a de longa duração entre a avaliação IDT e 7 dias após o treino (7dDT). O treinamento foi realizado em sessão única, com 5 repetições de cada um dos quatro jogos, sendo que a 2°, 3° e 4° o fisioterapeuta responsável interferiu por meio de pistas explícitas e implícitas, a fim de favorecer as respostas motoras dos pacientes. A pontuação nos jogos, tomadas como desfecho primário, serão analisadas por meio de ANOVA para medidas repetidas, considerando-se como fator as avaliações (AT, IDT, 48hDT e 7dDT), uma para cada um dos jogos. Acreditamos que os resultados deste estudo poderão contribuir com evidências, fundamentando o uso terapêutico do treino em RV para pacientes com AVE, com base no seu potencial de promover melhora do desempenho motor do MSP e a retenção desta melhora / The process of motor learning (ML) involves the reorganization of neural networks mediated by training, which enables an improvement in the performance of the trained task. The success of rehabilitation of patients with nerve damage is closely dependent on the potential of the applied training to activate and increase the ML process. The most limiting and refractory motor sequel of rehabilitation in patients victims of Cerebral Vascular Accident (CVA) is the paresis of the upper limb contralateral to the injured hemisphere. Therefore, the search for new training strategies that enhance the ML process has been a constant in the area. The virtual reality training (VR) is a new promise in this sense, because it could offer favorable conditions to ML. Despite the growing use of this type of tool for rehabilitation of the paretic upper limb (PUL) in patients with stroke, there is no consistent evidence about its potential to promote ML. Thus, the objective of this study was to investigate the improvement of short and long term performances after training for upper limbs (UL) in VR, based on Nintendo Wii® games (NW), in individuals with chronic sequelae of stroke. To achieve this goal, the performance of 22 individuals with chronic sequelae of stroke in UL, 17 men and 5 women in an average age of 52.7 ± 10.29 and 5.68 ± 5.31 years post stroke, was recorded in four NW games that require movements of UL with variable amplitude and speed that were compared before and after training. The intrasession acquisition was obtained by comparing the scores of the games before training (BT) and immediately after training (IAT), while the short-term retention was obtained by comparing the evaluation IAT and 48 hours after training (48hAT), and the long-term between IAT evaluation and 7 days after training (7dAT). The training was conducted in a single session, with five repetitions of each of the four games, in which 2nd, 3rd and 4th, the responsible physiotherapist directed through explicit and implicit clues, in order to benefit the motor responses of patients. The score in the games, taken as the primary endpoint, will be analyzed by ANOVA for repeated measures, considering as a factor assessments (BT, IAT, 48hAT and 7dAT), one for each of the games. We believe that the results of this study can contribute with evidences, substantiating the therapeutic use in VR for stroke patients, based on their potential to promote PUL motor performance improvement and its retention

Page generated in 0.0519 seconds