• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 52
  • 6
  • 6
  • 6
  • 6
  • 6
  • Tagged with
  • 52
  • 41
  • 40
  • 37
  • 36
  • 33
  • 32
  • 18
  • 16
  • 15
  • 14
  • 13
  • 13
  • 12
  • 10
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Resistência à fratura de diferentes núcleos de preenchimento com compósitos bulk fill em dentes com extensa destruição coronária /

Oliveira, Carlos Rangel de Moura January 2019 (has links)
Orientador: José Maurício dos Santos Nunes Reis / Resumo: Este estudo objetivou avaliar a resistência máxima e o padrão de fratura de diferentestécnicas para núcleo preenchimento associados a pinos de fibra de vidro em incisivoslaterais inferiores bovinos com extensa destruição coronária. Quarenta dentes forampreparados endodonticamente, divididos aleatoriamente em 4 grupos experimentais(n=10) e um pino de fibra de vidro (Whitepost DC0,5) foi cimentado com LuxaCore Zpara todos os grupos. A confecção dos núcleos de preenchimento foi realizada, apósobtenção de férula cervical de 1,0 mm, com: FOBF-Filtek One Bulk Fill; FZ350- FiltekZ350 XT; FBFF-Filtek Bulk Fill Flow; e LCZ-LuxaCore Z. Coroas totais de zircônia (YTZP) produzidas em CAD/CAM foram cimentadas com RelyX U200. Apósarmazenamento em água destilada a 37°C por 48 h, os corpos-de-prova foramsubmetidos a ciclos térmicos (10.000 ciclos, 5-55ºC, banhos de 30s) e, posteriormente,ao ensaio mecânico de resistência à fratura por força compressiva aplicada (1,0mm/min) em 135º ao longo eixo do dente em máquina eletromecânica (EMIC DL2000).A força máxima suportada por cada espécime foi registrada em Newton. O modo defratura foi classificado por meio de análise em lupa estereomicroscópica (30X). Osdados de resistência à fratura foram analisados pelo teste não paramétrico de KruskalWallis, seguido pelo post-hoc teste de Dunn. Os dados dos padrões de fratura foramanalisados pelo teste exato de Fisher (α=0,05). Não foram observadas diferençassignificativas (p>0... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This study aimed to evaluate the ultimate fracture strength and failure modes of different core techniques associated with intraradicular fiberpost in bovine mandibular lateral incisors with extensive coronary destruction. Forty teeth were prepared endodontically, randomly divided into 4 experimental groups (n=10) and a fiberpost (Whitepost DC0.5) was cemented with LuxaCore Z for all groups. The core was confeccioned, after obtaining a 1.0 mm cervical ferrule, with: FOBF-Filtek One Bulk Fill; FZ350- Filtek Z350 XT; FBFF-Filtek Bulk Fill Flow; and LCZ-LuxaCore Z. Total zirconia crowns (Y-TZP) produced by CAD/CAM were cemented with RelyX U200. After storage in distilled water at 37ºC for 48 h, the specimens were submitted to thermal cycling (10,000 cycles, 5- 55ºC, 30 s dwell time) and, afterwards, to the mechanical test of compressive strength fracture (1.0 mm / min) at 135º along the tooth axis in electromechanical machine (EMIC DL2000). The ultimate load supported by each specimen was recorded in Newton. The fracture mode was classified by means of stereomicroscopic loupe analysis (30X). The fracture strength data were analyzed by the non-parametric Kruskal-Wallis test, followed by the post-hoc Dunn test. The data of the fracture modes were analyzed by Fisher's exact test (α=0.05). No significant differences (p>0.05) were observed among the FOBF, FZ350 and FBFF groups (mean ranks= 20.30, 12.20 and 23.20, respectively). LCZ (mean rank= 26.30) produced similar results to those... (Complete abstract click electronic access below) / Mestre
42

Influência do modo de aplicação e viscosidade do ácido fosfórico 37% na adesão de pinos de fibra de vidro em condutos radiculares

Scholz, Maria Fernanda Costa 23 February 2018 (has links)
Submitted by Angela Maria de Oliveira (amolivei@uepg.br) on 2018-07-31T17:05:16Z No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) Maria Fernanda Costa Scholz.pdf: 1290758 bytes, checksum: ddb5c2c0ca43f593268a067c13b5296b (MD5) / Made available in DSpace on 2018-07-31T17:05:16Z (GMT). No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) Maria Fernanda Costa Scholz.pdf: 1290758 bytes, checksum: ddb5c2c0ca43f593268a067c13b5296b (MD5) Previous issue date: 2018-02-23 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O objetivo do presente estudo foi avaliar a influência da viscosidade do ácido fosfórico e do modo de aplicação nos valores de resistência de união de pino de fibra de vidro cimentados na dentina radicular através do teste de pushout. Raízes de 32 pré-molares foram preparadas endodonticamente e divididas em 4 grupos (n = 8) de acordo com a combinação dos seguintes fatores: viscosidade do ácido e forma de aplicação. Após aplicação do adesivo Universal no interior dos condutos, foram realizadas as cimentações dos pinos com o cimento resinoso RelyX ARC. Em seguida, as raízes foram seccionadas transversalmente em 6 fatias de aproximadamente 1 mm e o teste de push-out foi realizado a uma velocidade de 0,5 mm/min. Os resultados de resistência de união foram submetidos a uma análise de variância de três fatores de medidas repetidas e teste de Tukey (alpha = 0.05). A interação dupla modo de aplicação vs. viscosidade do ácido (p = 0,0002) e o terço radicular (p < 0,0001) foram estatisticamente significantes. O maior valor de resistência de união foi observado no grupo condicionado com ácido fosfórico líquido sob o modo de aplicação sônica (p < 0,05) sendo todos os outros grupos semelhantes entre si. Quanto ao terço radicular, observou-se maior valor de resistência de união no terço cervical, seguido do terço médio e do terço apical terço apical (p < 0,05). Pelos resultados pode-se concluir que uma melhor adesão de pinos de fibra de vidro ao conduto radicular pode ser obtida através do condicionamento com ácido fosfórico líquido com aplicação sônica. / The aim of the present study was to evaluate the influence of the etchant viscosity (liquid or gel) and the application mode (passive or sonic) on the pushout bond strength values of fiberglass post to root dentin and the conditioning pattern on the smear-layer covered root dentin before cementation. The roots of premolars were prepared endodontically and divided into 4 groups (n = 8) according to the combination of the main factors: phosphoric acid viscosity (liquid gel) and application mode (passive or sonic). After the application of the universal adhesive into the root canals, the fiberglass posts were cemented with cementation system RelyX ARC. Then, the roots were sectioned transversely 6 slices of approximately 1 mm and the push-out test performed at a speed 0.5 mm/min. The results were submitted to a repeated measures three-way ANOVA and Tukey’s test (alpha = 0.05). The cross-product interaction mode of application vs. etchant viscosity (p = 0.0002) and the main factor root third (p < 0.0001) were statistically significant. The highest bond strength value was observed when the conditioning of the root canal was performed with a liquid phosphoric acid under sonic application mode (p < 0.05), being all other groups similar one another (p < 0.05). Regarding the root third, the highest push-out bond strength value was observed in the cervical third, followed by the medium third and the apical thirds (p < 0,05). The most common fracture pattern was the mixed failure. By the partial results one may conclude that a better bonding of fiberglass posts to root canals can be achieved when the conduits are conditioned with a
43

Avaliação da espessura de cimento e resistência adesiva de pinos de fibra de vidro cônicos em preparo para retentor intra-radicular realizados com uma ponta ultrassônica desenvolvida / Assessment of cement thickness and bond strength of circular fiber posts in post space preparations with an ultrasonic tip developed

José Edgar Valdivia Cardenas 30 October 2017 (has links)
Preparos para retentores intra-radiculares mais conservadores evitam desgaste desnecessário da estrutura dentinária, requer menos cimento e podem melhorar a retenção adesiva do pino. Assim o objetivo deste estudo foi avaliar a espessura de cimento ea resistência adesiva de pinos de fibra de vidro cônicos em preparo para retentor intra-radicular realizados com uma ponta ultrassônica desenvolvida. Trinta incisivos laterais superiores foram preparados com limas reciprocantes Wave One Gold (Dentsply Sirona, Ballaigues, Suiça) e aleatoriamente divididos em 2 grupos (n=15) de acordo com a técnica de preparo para pino: grupo US foram preparados com uma ponta ultrassônica desenvolvida, e grupo WP (controle) com a broca recomendada pelo fabricante do pino. Os pinos de fibra de vidro cônicos WhitePost DC 0.5 (FGM, Joinville, SC, Brasil) foram cimentados utilizando cimento resinoso dual nos terços cervical e médio do canal radicular. Isto posto, todos os espécimes foram seccionados transversalmente em três seções (cervical, média e apical do pino) para análise da área de cimento resinoso ao redor do pino que foi calculada através do programa AutoCAD, em seguida, para avaliar a resistência adesiva, o teste de cisalhamento por extrusão foi aplicado através de uma maquina de ensaio universal numa velocidade média de 0.5 mm/min até o deslocamento do conjunto restaurador intra-radicular e o tipo de falha avaliado por estereomicroscopia. A comparação entre grupos e entre terços da área de cimento e resistência adesiva foram analisadas pelo teste t independente e Anova com Tukey; e os tipos de falha entre os grupos por Mann-Whitney, todos com nível de significância de 5%. No grupo ultrassônico foi observado a menor quantidade de cimento (p<0.05) e a resistência adesiva nos diferentes grupos e terços se manifestou maior somente no terço apical do grupo ultrassônico (p<0.05). Falha adesiva entre cimento e dentina foi a mais prevalente do terço cervical e apical do grupo US e cervical de grupo WP. Falha adesiva entre cimento e pino foi a mais prevalente nos demais terços. Conclui-se que o preparo para retentor com a ponta ultrassônica desenvolvida requer menor quantidade de cimento e influencia na melhor resistência de união no terço apical do pino de fibra de vidro. / Conservative post space preparations for intra-radicular retainers prevent unnecessary desgaste of the dentin structure, require less cement and improve bond strength of the post. The aim of this study was to evaluate the influence of resin cement thickness and bond strength of prefabricated glass fiber circular postin post space preparations with an ultrasonic tip developed. Thirtymaxillarylateral incisors were prepared with Wave One Gold reciprocating files (Dentsply Sirona, Ballaigues, Switzerland) and randomly divided into 2 groups (n=15) according to the post preparation technique: gruoup US was prepared with an ultrasonic tip developed and group WP (control) with the drill recommended by the post fabricant. Every glass fiber posts WhitePost DC 0.5 (FGM, Joinville, SC, Brazil) was cemented using dual polymerizing resin cement in the cervical and middle thirdof the root canal. After that, every specimen was sectioned transversally into three sections(cervical, middle and apical of the post) and the resin cement thickness area was calculated with AutoCAD program, the bond strength test was done with an universal testing machineat medium velocity 0.5 mm/min and the failure pattern after the test was analyzed with stereomicroscopy. Datas obtained were analyzed statistically using Student\'s t-Test, ANOVA,andTukey\'s test. The comparison of failure modes between the groups in the different thirds was done using Mann-Whitney test, All of those at a 5% significance. Ultrasonic group presented thinnest layer of cement in all thirds (p<0,05), which also obtained a higher bond strength only in apical third (p<0,05). Adhesive failurebetween cement and dentinwas the most prevalent of the cervical and apical third of G1 and cervical of G2.Adhesive failure between cement and post was the most prevalent in the others thirds. It can be concluded that the postpreparation with the ultrasonic tip developed provides a smaller thickness of resin cement that influenced thebond strength in the apical third of the glass fiber post.
44

Avaliação da customização por desgaste de pinos pré-fabricados de fibra de vidro / Evaluation of fibre posts submitted to customization of the apical portion

Ana Regina Cervantes Dias 25 January 2012 (has links)
O objetivo deste estudo foi avaliar pinos pré-fabricados de fibra de vidro (White Post DC/FGM) submetidos à customização por desgaste da porção apical. Experimento 1: 5 pinos n. 4 foram divididos em 5 grupos (G) de acordo com o instrumento de desgaste: GA - sem desgaste, GB- mini torno industrial (Dentsply), GC - ponta diamantada n. 3195F (KG Sorensen), GD - disco de lixa de granulação média (Sof-Lex/3M/ESPE), GE- alicate (Tramontina). Observou-se a micromorfologia dos pinos em microscópio eletrônico de varredura (ZEISS/DSM 960). Experimento 2: 60 pinos de diferentes diâmetros foram divididos em 6 grupos: G0 - pinos n. 0,5, G1 - pinos n. 1, G2 - pinos n. 2, G3 - pinos n. 3, G4 - pinos n.4, G5 - pinos n. 4 com terço apical desgastado com discos de lixa até o equivalente ao terço apical dos pinos n. 2. Os pinos foram submetidos ao teste de flexão de 3 pontos na máquina de ensaios universal (Instron 5500 R), conforme ISO 10477. Experimento 3: 20 caninos humanos permanentes sofreram tratamento endodôntico e remoção das coroas clínicas padronizando 15 mm de remanescente radicular. Os dentes foram incluídos em resina acrílica com simulação do ligamento periodontal, receberam férula de 2 mm e foram divididos em 2 grupos: GI - pinos n. 4 cimentados em condutos preparados com broca equivalente ao pino (FGM), GII - pinos n. 4 customizados no terço apical cimentados em condutos preparados com brocas (FGM) equivalentes aos pinos n. 2 em 10 mm e n. 4 em 5 mm. Os pinos foram cimentados com cimento resinoso (Rely X U100/3M/ESPE), os corpos de prova receberam coroas diretas de resina composta (Enforce Core/Dentsply) padronizadas com coras de policarbonato (TDV) e foram submetidos ao teste de resistência à fratura na Instron a 45da ferramenta cilíndrica, com força de 500 N aplicada a 2 mm da incisal na face palatina/lingual, com velocidade de 0,5 mm/min até falha. O padrão de fratura foi classificado em favorável ou desfavorável. Os resultados foram tratados estatisticamente por teste de análise de variância (ANOVA, p<0,05). Os resultados dos testes de flexão e fratura foram respectivamente: G0 - 58,406,40; G1 - 83,959,43; G2- 103,4219,17; G3 - 160,7817,30; G4 - 170,4711,28; G5 - 106,3521,96; GI - 303,0262,21 e GII - 402,81131,97. O padrão de fratura foi tratado por Mann-Whitney que observou semelhança estatística entre os grupos. Concluiu-se que o desgaste de pinos de fibra de vidro com pontas diamantadas ou discos de lixa produz alterações micromorfológicas aceitáveis. O corte com alicate deve ser evitado. A customização por desgaste da porção apical de pinos de fibra de vidro diminui a resistência à flexão a valores aceitáveis. Dentes restaurados com pinos de fibra de vidro customizados por desgaste possuem resistência à fratura superior a dentes restaurados com pinos intactos. A customização por desgaste facilita a adaptação do pino ao conduto radicular e preserva a estrutura dental. / The purpose of this study was to evaluate fibre posts (White Post DC/FGM) submitted to customization of the apical portion. Experiment 1: 5 #4 posts were divided into five groups (G) and submitted to different custom adaptation treatments: GA no surface treatment, GB- industrial shaping tool (Dentsply), GC- #3195 fine diamond bur (KG Sorensen), GD- medium-grain paper discs (Sof-Lex/3M/ESPE), GE pliers (Tramontina). The micromorphology of the posts was observed in a scanning electron microscope (ZEISS/DSM 960). Experiment 2: 60 posts of different diameters were divided into six groups: G0 #0.5 posts, G1 #1 posts, G2 #2 posts, G3 - #3 posts; G4 - #4 posts and G5 #4 posts submitted to custom adaptation of the apical portion with paper discs until the diameter was equivalent to #2 posts. The posts were submitted to a 3 point bending test in a universal testing machine (Instron/5500 R), according to ISO 10477. Experiment 3: 20 freshly extracted permanent healthy human canines with similar size were endodontically treated and the crowns were removed, leaving a remaining root length of 15 mm. The teeth were embedded in acrylic resin with simulation of the periodontal ligament, received a 2 mm ferule and were divided into two groups: G1- 10 #4 posts were cemented into post spaces prepared with #4 drill (FGM) at 10 mm, G2 - 10 #4 customized posts were cemented into root spaces prepared with #2 drill (FGM) at 10 mm and #4 drill (FGM) at 5 mm. The posts were cemented with resin cement (Rely X U100/3M/ESPE), and the teeth received direct crowns of composite resin (Enforce Core/Dentsply), standardized with polycarbonate crowns (TDV). The fracture strength was measured on an Instron, at 45 degrees to the long axis of the tooth, until fracture. The 500 N cylindrical load was applied to the buccal/lingual axis 2 mm below the incisal line, at crosshead speed of 0.5 mm/min. The fracture pattern was observed and classified as favorable or unfavorable. The results were submitted to ANOVA (p<0.05). Flexural strength and resistance to fracture data were, respectively: G0 58.40+6.40; G1 83.95+9.43; G2 103.42+19.17; G3 160.78+17.30; G4- 170.47+11.28; G5 106.35+21.96;GI 303.02+62.21 and GII 402.81+131.97. Fracture patterns were statistically similar according to Mann-Whitney test. It was concluded that customization of fibre posts with diamond burs or paper discs produces acceptable micromorphological changes. The cut of the post with pliers should be avoided. Grounding of the apical portion of fibre posts reduces the flexural strength to acceptable values. Teeth restored with grounded fiber posts have grater fracture strength than teeth restored with intact posts. Grounding of the post facilitates adaptation to root walls and preserves tooth structure.
45

Efeito da ciclagem mecânica sobre a resistência de união de pinos intra-radiculares de fibra cimentados com resina à dentina

Soares, Luiz Felipe Valandro [UNESP] 09 December 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:01Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-12-09Bitstream added on 2014-06-13T19:44:48Z : No. of bitstreams: 1 soares_lfv_dr_sjc.pdf: 2172167 bytes, checksum: afe324626620aad27736c29fa48ab77b (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Este estudo avaliou o efeito da ciclagem mecânica sobre a resistência de união de pinos intra-radiculares de fibra cimentados com resina à dentina. As hipóteses desse trabalho são que a resistência adesiva não varia após o teste de fadiga e também não varia em função do tipo de pino de fibra. A parte coronária de 60 dentes humanos unirradiculares foi seccionada, obtendo-se espécimes (sp) de 16mm, que foram submetidos à instrumentação endodôntica e então 30 sp foram preparados (12mm) para receber um pino de fibra de quartzo (D.T. Light-Post) [DT] e 30 foram preparados para um pino de fibra de vidro (FRC Postec Plus) [FRC]. Os pinos foram cimentados (All-Bond + cimento resinoso Duolink) e a parte radicular dos sp foi embutida em resina epóxica até 3mm da porção cervical. Foram constituídos 6 grupos (n=10), considerando o tipo de pino de fibra e o regime de ciclagem mecânica (carga: 50 N; 45° em relação ao longo eixo do sp; freqüência: 8Hz): G1- DT + sem ciclagem; G2- DT + 20.000 ciclos; G3- DT + 2.000.000 ciclos; G4- FRC + sem ciclagem; G5- FRC + 20.000 ciclos; G6- FRC + 2.000.000 ciclos. Os sp foram então seccionados perpendicularmente ao longo eixo do sp,obtendo-se fatias de aproximadamente 2mm (4 secções / sp) que foram submetidas ao ensaio de push-out em máquina de ensaio universal (1mm.min-1). A média de resistência adesiva das repetições de cada espécime foi obtida e os dados (n=10) foram submetidos à análise estatística (a=0,05). A ANOVA mostrou que: (a) as resistências adesivas do pino DT (7,12 l 2,20 MPa) e do pino FRC (6,87 l 2,12 MPa) foram estatisticamente semelhantes entre si (P=0,665); (b) os valores obtidos para a condição sem ciclagem (6,96 l 2,44 MPa), 20.000 (6,99 l 2,08 MPa) e 2.000.000 (7,02 l 2,00 MPa) foram similares estatisticamente (P=0,996); (c) os 6 grupos foram estatisticamente semelhantes entre si (P=1,000)... / This study evaluated the effect of the mechanical cycling on the bond strength of fiber posts resin bonded to root dentin. The tooth crown of the 60 single-rooted human teeth was cut, leaving a 16-mm long root specimens (sp) that were endondontically treated and the space prepared in 12mm. Thirty sp received a quartz fiber post (D.T. Light-Post) and 30 sp received a glass fiber post (FRC Postec Plus). The posts were resin luted in the post space and each sp was embedded with epoxy resin (resin 285, Schaller, Florence, Italy) in a PVC cylinder (height: 25 mm, diameter: 10 mm). Sp were divided into 6 groups, considering the fiber post type and number of the mechanical cycles (load: 50 N; angle of 45°; frequency: 8Hz): G1- DT + without cycling; G2- DT + 20,000 cycles; G3- DT + 2,000,000 cycles; G4- FRC + without cycling; G5- FRC + 20,000 cycles; G6- FRC + 2,000,000 cycles. The sp were cut perpendicular to their long axis, to form 2-mm-thick disk-samples (4 sections / sp), which were submitted to the push-out test (1mm.min-1). The mean bond strength values were calculated for each tooth (n=10) and data were statistical analyzed (a=.05). ANOVA revealed that: (a) the bond strengths of DT (7,12 l 2,20 MPa) and of FRC (6,87 l 2,12 MPa) were statistically similar (P=0,665); (b) the mean values for the without cycling groups (6,96 l 2,44 MPa), 20,000 cycles groups (6,99 l 2,08 MPa) and 2,000,000 cycles groups (7,02 l 2,00 MPa) were not statistically different (P=0,996); (c) the 6 groups were not statistically different (P=1,000). It was concluded that the mechanical cycling did not affect the bond strength of two fiber posts resin bonded to dentin.
46

RESISTÊNCIA À FRATURA DE DENTES COM RAÍZES FRAGILIZADAS RESTAURADOS COM DIFERENTES RETENTORES INTRARRADICULARES / FRACTURE RESISTANCE OF WEAKENED ROOTS RESTORED BY DIFFERENT POST SYSTEMS

Broch, Juliana 02 March 2012 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Taking into account the importance of developing techniques to restore teeth with excessively flared root canals, this study aimed to evaluate the effect of mechanical cycling on the fracture resistance of teeth with weakened roots, restored with different techniques, as well as to analyze the failure modes after fracture testing. Eighty (N=80) bovine lower incisors were selected and the coronal and cervical portions were sectioned to standardize the specimens length at 15 mm. The roots were endodontically treated and prepared to 10 mm in intracanal length. The cervical portion of the root inner surface (5 mm) was enlarged (removing the intracanal dentin) using a diamond drill (KG Sorensen #4138) to produce a radicular wall with 1 mm in thickness. The specimens were embedded with acrylic resin and the periodontal ligament was simulated with a polyether material. Afterwards, the specimens were randomly allocated in 4 intracanal restoring strategies: cast post and core; double-tapered glass fiber post with cervical emerging diameter of 1.8 mm; double-tapered glass fiber post with cervical emerging diameter of 2.2 mm; anatomic posts (fiber posts relined with composite resin). Each restoring method was assessed without or with mechanical cycling, applying the protocol as followed: angle of 45º, 37ºC temperature, load of 88N, frequency of 2.2 Hz, 1.000.000 load-pulses. All of the restored teeth received metal full crown (Ni-Cr). All the specimens were submitted to fracture resistance at 45º and at a cross-head speed of 0.5 mm/min. Two-way ANOVA and Tukey showed that the root post system (p < 0.0004), the mechanical cycling (p < 0.003) and the interaction between the factors (p < 0.02) were statistically significant. The restoring methods with fiber posts did not change after mechanical cycling. Its fracture strength values were similar to that from cast post and core. The anatomic post suffered degradation with the mechanical cycling (the values reduced after aging). Concerning the mode of failure, the most failure from groups restored with cast post and core were catastrophic while the others groups showed a predominance of repairable failures. / Diante da necessidade do desenvolvimento de técnicas capazes de restaurar adequadamente raízes com condutos alargados, este trabalho visou avaliar o efeito da ciclagem mecânica sobre a resistência à fratura de dentes com raízes fragilizadas e restaurados com diferentes retentores intrarradiculares, bem como analisar o padrão de falha destes dentes quando submetidos à carga compressiva. Foram utilizados para este estudo 80 incisivos inferiores bovinos, cujas raízes foram seccionadas em 15 mm de comprimento, tratadas endodonticamente e preparadas até 10 mm de profundidade. Os 5 mm cervicais dos canais radiculares destas raízes foram fragilizados com uma ponta diamantada (4138), de modo a gerar uma espessura de parede radicular de 1 mm. As raízes foram incluídas em resina acrílica autopolimerizável e o ligamento periodontal foi simulado com material elastomérico (poliéter). Após, as raízes foram distribuídas aleatoriamente em quatro sistemas de retentores intrarradiculares: núcleo metálico fundido, pino de fibra de vidro (pinos de dupla conicidade, 1,8 mm de diâmetro cervical), pino de fibra de vidro especial (pinos de dupla conicidade, 2,2 mm de diâmetro cervical) e pino anatômico. Cada um desses sistemas de retentores foi avaliado com e sem ciclagem mecânica, sendo o protocolo de ciclagem o seguinte: angulação de 45°, temperatura de 37°C, força de 88N, freqüência de 2,2 Hz, totalizando 1 milhão de ciclos; durante a mesma os espécimes dos grupos sem ciclagem mecânica ficaram armazenados em água destilada. Em todos os grupos, foram cimentadas coroas totais metálicas de Níquel-Cromo sobre o núcleo. Os corpos de prova de todos os grupos foram submetidos ao teste de resistência à compressão em uma inclinação de 45° e à velocidade de 0,5 mm/mim até ocorrer a falha. A análise de Variância seguida de Tukey mostrou que o tipo de retentor intrarradicular (p < 0,0004), a ciclagem mecânica (p < 0,003) e a interação entre ambos (p < 0,02), foram estatisticamente significantes. Os pinos de fibra de vidro mantiveram-se estáveis após a ciclagem mecânica, com valores de resistência à fratura similares aos núcleos metálicos fundidos. Somente pinos anatômicos sofreram degradação com a ciclagem, reduzindo significativamente os valores de resistência à fratura. Em relação ao padrão de falha, foram fraturas predominantemente irreversíveis nos grupos reconstruídos com núcleo metálico fundido, e nos demais, reversíveis.
47

Influência da perda óssea, tipo de retentor e presença de remanescente coronário no comportamento biomecânico de caninos superiores tratados endodonticamente

Roscoe, Marina Guimarães 27 February 2013 (has links)
Fundação de Amparo a Pesquisa do Estado de Minas Gerais / The presence of bone loss is related to changes in the biomechanical behavior of endodontically treated teeth. The purpose of this study was to evaluate the effect of alveolar bone loss, ferrule presence and post type on the biomechanical behavior of endodontically treated maxillary canines restored with all-ceramic crowns. For the experimental analysis, forty upper human canines were selected and divided into 8 experimental groups according 3 treatment variations: bone support, without or with 5.0 mm of bone loss; ferrule presence, with or without 2.0mm of ferrule; and post type, restored with cast post and cores or glass fiber post. The restored canines were loaded at a 15- degree angle, and the deformation was measured using strain gauges placed on the buccal and proximal root surfaces. Strain results were analyzed by 3- way-ANOVA and Tukey HSD tests (&#945;=.05). For the finite element analysis, eight 3-D models were created, following the same variations of the experimental analysis. The models were analyzed using the maximum principal stress criteria for stress distribution analysis. The presence of ferrule decreased significantly the buccal and proximal strain. The type of post showed slightly influence on the stress distribution. The presence of bone loss increased significantly the stress concentration and strain values in both regions mainly on root dentin and surrounding cortical bone. Can be possible to conclude that the presence of a ferrule improved the mechanical behavior, irrespective of the type of post. The 5.0mm of bone loss increased significantly the stress concentration and the strain on the root dentin. / A perda de inserção óssea está relacionada a mudanças no comportamento biomecânico de dentes tratados endodonticamente. O objetivo deste estudo foi avaliar o efeito da perda óssea alveolar, da presença de remanescente coronário e do tipo de retentor intra-radicular no comportamento biomecânico de caninos tratados endodonticamente e restaurados com cora em cerâmica pura. Para a análise experimental, quarenta caninos superiores foram selecionados e divididos em 8 grupos experimentais (n=10), de acordo com três fatores em estudo: suporte ósseo, ausência e presença de 5.0mm de perda óssea; remanescente coronário, ausência e presença de 2.0mm de remanescente coronário; e tipo de retentor, núcleo moldado e fundido e pino de fibra de vidro. Os caninos foram restaurados com cora em cerâmica pura reforçada por disilicato de lítio. As amostras foram submetidas ao carregamento de compressão a 15º em relação ao longo eixo do dente, e a deformação mensurada por extensômetros fixados nas superfícies radiculares vestibular e proximal. Os valores de deformação foram submetidos a Análise de variância fatorial 2X2X2 seguido pelo teste Tukey HSD (&#945;=0,05). Para a análise de elementos finitos, oito modelos foram criados, simulando as mesmas variáveis da análise experimental. Todas as estruturas foram consideradas homogêneas e isotrópicas, a exceção do pino de fibra de vidro, considerado ortotrópico. Foi utilizado o critério de máxima tensão principal para análise de distribuição de tensões. A presença do remanescente coronário diminuiu significativamente a deformação vestibular e proximal. O tipo de pino mostrou pequena influência na distribuição de tensões. A presença da perda óssea aumentou significativamente a concentração de tensões, principalmente na dentina radicular e no osso cortical, e os valores de deformação em ambas as regiões mensuradas. Pode-se concluir que a presença de remanescente coronário dentinário melhorou o comportamento biomecânico, independente do tipo de pino. A presença da perda óssea alveolar de 5.0mm aumentou significativamente os valores de deformação e a concentração de tensões na dentina radicular. / Mestre em Odontologia
48

Avaliação da customização por desgaste de pinos pré-fabricados de fibra de vidro / Evaluation of fibre posts submitted to customization of the apical portion

Ana Regina Cervantes Dias 25 January 2012 (has links)
O objetivo deste estudo foi avaliar pinos pré-fabricados de fibra de vidro (White Post DC/FGM) submetidos à customização por desgaste da porção apical. Experimento 1: 5 pinos n. 4 foram divididos em 5 grupos (G) de acordo com o instrumento de desgaste: GA - sem desgaste, GB- mini torno industrial (Dentsply), GC - ponta diamantada n. 3195F (KG Sorensen), GD - disco de lixa de granulação média (Sof-Lex/3M/ESPE), GE- alicate (Tramontina). Observou-se a micromorfologia dos pinos em microscópio eletrônico de varredura (ZEISS/DSM 960). Experimento 2: 60 pinos de diferentes diâmetros foram divididos em 6 grupos: G0 - pinos n. 0,5, G1 - pinos n. 1, G2 - pinos n. 2, G3 - pinos n. 3, G4 - pinos n.4, G5 - pinos n. 4 com terço apical desgastado com discos de lixa até o equivalente ao terço apical dos pinos n. 2. Os pinos foram submetidos ao teste de flexão de 3 pontos na máquina de ensaios universal (Instron 5500 R), conforme ISO 10477. Experimento 3: 20 caninos humanos permanentes sofreram tratamento endodôntico e remoção das coroas clínicas padronizando 15 mm de remanescente radicular. Os dentes foram incluídos em resina acrílica com simulação do ligamento periodontal, receberam férula de 2 mm e foram divididos em 2 grupos: GI - pinos n. 4 cimentados em condutos preparados com broca equivalente ao pino (FGM), GII - pinos n. 4 customizados no terço apical cimentados em condutos preparados com brocas (FGM) equivalentes aos pinos n. 2 em 10 mm e n. 4 em 5 mm. Os pinos foram cimentados com cimento resinoso (Rely X U100/3M/ESPE), os corpos de prova receberam coroas diretas de resina composta (Enforce Core/Dentsply) padronizadas com coras de policarbonato (TDV) e foram submetidos ao teste de resistência à fratura na Instron a 45da ferramenta cilíndrica, com força de 500 N aplicada a 2 mm da incisal na face palatina/lingual, com velocidade de 0,5 mm/min até falha. O padrão de fratura foi classificado em favorável ou desfavorável. Os resultados foram tratados estatisticamente por teste de análise de variância (ANOVA, p<0,05). Os resultados dos testes de flexão e fratura foram respectivamente: G0 - 58,406,40; G1 - 83,959,43; G2- 103,4219,17; G3 - 160,7817,30; G4 - 170,4711,28; G5 - 106,3521,96; GI - 303,0262,21 e GII - 402,81131,97. O padrão de fratura foi tratado por Mann-Whitney que observou semelhança estatística entre os grupos. Concluiu-se que o desgaste de pinos de fibra de vidro com pontas diamantadas ou discos de lixa produz alterações micromorfológicas aceitáveis. O corte com alicate deve ser evitado. A customização por desgaste da porção apical de pinos de fibra de vidro diminui a resistência à flexão a valores aceitáveis. Dentes restaurados com pinos de fibra de vidro customizados por desgaste possuem resistência à fratura superior a dentes restaurados com pinos intactos. A customização por desgaste facilita a adaptação do pino ao conduto radicular e preserva a estrutura dental. / The purpose of this study was to evaluate fibre posts (White Post DC/FGM) submitted to customization of the apical portion. Experiment 1: 5 #4 posts were divided into five groups (G) and submitted to different custom adaptation treatments: GA no surface treatment, GB- industrial shaping tool (Dentsply), GC- #3195 fine diamond bur (KG Sorensen), GD- medium-grain paper discs (Sof-Lex/3M/ESPE), GE pliers (Tramontina). The micromorphology of the posts was observed in a scanning electron microscope (ZEISS/DSM 960). Experiment 2: 60 posts of different diameters were divided into six groups: G0 #0.5 posts, G1 #1 posts, G2 #2 posts, G3 - #3 posts; G4 - #4 posts and G5 #4 posts submitted to custom adaptation of the apical portion with paper discs until the diameter was equivalent to #2 posts. The posts were submitted to a 3 point bending test in a universal testing machine (Instron/5500 R), according to ISO 10477. Experiment 3: 20 freshly extracted permanent healthy human canines with similar size were endodontically treated and the crowns were removed, leaving a remaining root length of 15 mm. The teeth were embedded in acrylic resin with simulation of the periodontal ligament, received a 2 mm ferule and were divided into two groups: G1- 10 #4 posts were cemented into post spaces prepared with #4 drill (FGM) at 10 mm, G2 - 10 #4 customized posts were cemented into root spaces prepared with #2 drill (FGM) at 10 mm and #4 drill (FGM) at 5 mm. The posts were cemented with resin cement (Rely X U100/3M/ESPE), and the teeth received direct crowns of composite resin (Enforce Core/Dentsply), standardized with polycarbonate crowns (TDV). The fracture strength was measured on an Instron, at 45 degrees to the long axis of the tooth, until fracture. The 500 N cylindrical load was applied to the buccal/lingual axis 2 mm below the incisal line, at crosshead speed of 0.5 mm/min. The fracture pattern was observed and classified as favorable or unfavorable. The results were submitted to ANOVA (p<0.05). Flexural strength and resistance to fracture data were, respectively: G0 58.40+6.40; G1 83.95+9.43; G2 103.42+19.17; G3 160.78+17.30; G4- 170.47+11.28; G5 106.35+21.96;GI 303.02+62.21 and GII 402.81+131.97. Fracture patterns were statistically similar according to Mann-Whitney test. It was concluded that customization of fibre posts with diamond burs or paper discs produces acceptable micromorphological changes. The cut of the post with pliers should be avoided. Grounding of the apical portion of fibre posts reduces the flexural strength to acceptable values. Teeth restored with grounded fiber posts have grater fracture strength than teeth restored with intact posts. Grounding of the post facilitates adaptation to root walls and preserves tooth structure.
49

Biodinamica restauradora de dentes tratados endodonticamente : analise por elementos finitos / Restorative biomechanical of endodontic treated teeth : finite element analysis

Santos Filho, Paulo Cesar de Freitas 04 June 2009 (has links)
Orientador: Luis Roberto Marcondes Martins / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-13T11:40:25Z (GMT). No. of bitstreams: 1 SantosFilho_PauloCesardeFreitas_D.pdf: 10660151 bytes, checksum: bd3f67697b369623400074dcf22ec01c (MD5) Previous issue date: 2009 / Resumo: O objetivo deste estudo foi desenvolver protocolo de modelagem tridimensional para incisivo central superior com aplicabilidade ao método de elementos finitos e avaliar o comportamento biomecânico de incisivo superior tratado endodonticamente e restaurado com retentores e coroa cerâmica por meio de análise por elementos finitos comparado ao dente hígido. Para geração do modelo 3D foi selecionado incisivo central superior hígido. Esmalte e dentina foram degradados em diferentes fases com ácido clorídrico-10%, e mapeados com scanner de contato 3D (Modela, Roland). Para o mapeamento do volume pulpar, a dentina foi seccionada longitudinalmente no sentido mesio-distal e realizado o escaneamento do espaço negativo referente à polpa. Os arquivos *.STL foram exportados para programa Bio-CAD (Rhinoceros-3D). Volumes de cada estrutura dental e técnicas restauradoras foram gerados por meio da associação de superfícies NURBS. Os modelos foram exportados para o programa de elementos finitos (FEMAP-NeiNastran), onde foi realizado o processo de malhagem, inserção das propriedades mecânicas e condições de contorno. Foram gerados 17 modelos, sendo um do dente hígido e 16 modelos de acordo com os 4 fatores em estudo: tipo de retentor em dois níveis: pino de fibra de vidro (PFV) e núcleo moldado fundido (NMF), extensão do retentor em dois níveis: 7,0mm (7,0) e 12,0mm (12,0), remanescente coronário em dois níveis: remanescente de 2,0mm (RE) e ausência de remanescente (ARE), enfraquecimento do canal radicular em dois níveis: ausência de enfraquecimento (AENF) e presença de enfraquecimento (ENF). Foi simulada aplicação de pressão constante no valor de 100N perpendicularmente à superfície palatina do incisivo. Os resultados foram analisados pelo critério de von Mises e tensão máxima principal. Os resultados obtidos mostraram que o modelo geométrico 3D desenvolvido é adequado para a análise por elementos finitos. Concluiu-se que o PFV apresenta distribuição homogênea das tensões mais semelhante ao dente hígido, enquanto o NMF apresentou grande concentração de tensão no interior do canal radicular. O fator extensão do retentor intra-radicular influenciou isoladamente apenas a distribuição de tensões do NMF. A presença de remanescente coronário sempre melhorou a distribuição de tensões. O enfraquecimento do canal radicular teve maior impacto na distribuição de tensões. / Abstract: The aim of this study was develop 3D model generation protocol for upper anterior teeth for finite element analysis and evaluate biomechanical behavior of endodontically treated incisor with finite element analysis compared to sound teeth. It was selected intact upper central incisor. Enamel and dentin were treated in different steps with cloridric acid 2% and scanned with 3D-contact scanner. The stereolithographics archives were exported to Bio CAD program. The volums of each dental structure and restorative techniques were generated by association of NURBS surfaces. The models were exported for finite element software, where were realized the meshed process, mechanical properties insertion and bondary conditions. It were generated 17 models, one was a sound incisor model and 16 models according to 4 studied factors: post type: glass fiber post (GFP) and cast post and core (CPC), post length: 7,0mm (7,0) e 12,0mm (12,0), ferrule: 2,0mm ferrule (FE) and absence of ferrule (AFE), weakness of root canal: absence of weakness (AWR) and weakened root (WR). It was simulated 100N loading application on the palatal surface with 135° angulation. The results were analised by Von Mises criteria and principal maximum tension. Obtained results showed that geometric model developed is appropriated for finite element analysis. It can be concluded that GFP showed homogeneous stress distribution like the sound incisor, while CPC showed stress concentration into root canal. The post length influenced only the CPC stress distribution. The ferrule always showed better stress distribution. The weakness of root showed the highest impact in stress distribution. / Doutorado / Dentística / Doutor em Clínica Odontológica
50

Estudo in vitro da adaptação de retentores intra-radiculares fundidos, modelados com diferentes resinas acrílicas autopolimerizáveis / In vitro study of the fit of cast post and core, obtained from different acrylic resin patterns

Denise Galhardo Rennó 21 September 2005 (has links)
Dentes tratados endodonticamente se encontram freqüentemente mutilados por cárie ou pelo próprio acesso ao canal. A estrutura dental remanescente necessita de tratamento especial para prevenir futuras fraturas. Quando uma grande parte da coroa dental foi perdida, é comum não haver retenção para a restauração na dentina remanescente. Nestas situações, uma restauração com retenção intracanal se faz necessária. Apenas a porção radicular pode oferecer a retenção apropriada para a instalação de uma coroa artificial estética e funcional. Diferentes técnicas podem ser usadas para a fabricação do retentor intra-radicular fundido. Neste estudo, foi escolhida a técnica direta para a confecção dos padrões de fundição em resina acrílica autopolimerizável. Usamos seis padrões metálicos com dimensões que simulavam dentes anteriores preparados para receber um retentor intra-radicular. Os condutos foram preenchidos com resina acrílica, usando um pincel bem fino, e pinos plásticos foram inseridos no interior dos canais. Após a polimerização do pino, adicionamos novas porções de resina acrílica para confecção das partes correspondentes aos núcleos. Essa técnica permite a correção de eventuais falhas, caso haja necessidade. Os padrões de fundição foram então incluídos em material de revestimento e fundidos em liga de níquel-cromo. O retentor intra-radicular fundido foi removido do revestimento e limpo. Apenas removemos os nódulos da superfície do metal, a qual recebeu, posteriormente, jateamento com óxido de alumínio. O objetivo deste estudo foi comparar a adaptação marginal de 54 retentores intra-radiculares fundidos, modelados com três resinas acrílicas autopolimerizáveis diferentes: 18 em DuraLay (Reliance Dental MFG Co., USA); 18 em Pattern Resin (GC Products, Japan); 18 em Cop Clas (Artigos Odontológicos Clássico Ltda., Brasil). Os retentores intra-radiculares fundidos foram assentados sobre os seis padrões metálicos. As fendas marginais foram observadas em microscópio eletrônico de varredura (MEV). As medições foram registradas e submetidas à análise estatística. Os resultados obtidos mostraram que: (1) Os retentores intra-radiculares fundidos obtidos de padrões de fundição modelados com a resina DuraLay mostraram-se significativamente melhor adaptados (42,31 µm ± 9,54 µm) quando comparados aos retentores intra-radiculares fundidos obtidos de padrões das resinas Pattern Resin (73,25 µm ± 32,86 µm) e Cop Clas (95,32 µm ± 45,02 µm) respectivamente; (2) Não houve diferença estatisticamente significante (p=0,273) na diferença média das fendas marginais dos retentores intra-radiculares fundidos modelados com a resina Pattern Resin e modelados com a resina Cop Clas (22,07 µm ± 13,13 µm). / Endodontically treated teeth are often mutilated by caries and access requirements. The remaining structure requires special treatment to prevent further destruction. When a large portion of the clinical crown has been lost, it is often impossible to achieve sufficient anchorage of a restoration in the remaining dentin. In such situations, a root-canal-retained restoration is required. Only the root portion can offer the needed retention for a functional and esthetic artificial crown. Different approaches can be taken to the fabrication of cast posts and cores. In this study, direct method was chosen to fashion it, by auto polymerizing acrylic resin. We used six standard metal patterns that simulate an anterior tooth prepared to receive cast post and core. Burn-out plastic patterns were fitted into the root canal and, using a fine sable hair brush, the polymer was introduced to fill the canal. After polymerization of the post, additional auto -polymerizing acrylic resin was added to form the core portion. This process can be repeated and correct if necessary. The acrylic resin patterns were then invested and casting was performed using nickel-chromium alloy. The cast was removed from investment. Cleaning was performed exclusively to remove the small positive nodules on the metal post and sandblast surface. The aim of this research was to compare the marginal fit of 54 cast posts constructed with three auto -polymerizing acrylic resins: 18 of DuraLay (Reliance Dental MFG Co., USA); 18 of Pattern Resin (GC Products, Japan); 18 of Cop Clas (Artigos Odontológicos Clássico Ltda., Brasil). The posts and cores were seated over the six standard metal patterns. Marginal discrepancies were bserved in scanning electron microscope (SEM). The measurements were registered and statistically analyzed. The results obtained showed that: (1) The cast post and core obtainedfrom DuraLay (42,31 µm ± 9,54 µm) had significant best fit than the cast post and core obtained from the others acrylic resins, Pattern Resin (73,25 µm ± 32,86 µm) and Cop Clas (95,32 µm ± 45,02 µm) respectively; (2) No significant statistic difference occur p=0,273) in the average marginal gap between the cast posts and cores obtained from Pattern Resin and Cop Class (22,07 µm ± 13,13 µm).

Page generated in 0.0519 seconds