361 |
Gestão de resíduos sólidos sob a ótica da tecnologia social: Uma experiência em Campina Grande – PBSousa, Matheus Urtiga 27 February 2018 (has links)
Submitted by Jean Medeiros (jeanletras@uepb.edu.br) on 2018-04-10T18:59:41Z
No. of bitstreams: 1
PDF - Matheus Urtiga Sousa.pdf: 78237638 bytes, checksum: 0197954c3aa0940936038dbc7304baf4 (MD5) / Made available in DSpace on 2018-04-10T18:59:41Z (GMT). No. of bitstreams: 1
PDF - Matheus Urtiga Sousa.pdf: 78237638 bytes, checksum: 0197954c3aa0940936038dbc7304baf4 (MD5)
Previous issue date: 2018-02-27 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / Integrated management is a set of actions aimed at finding solutions to the problems arising from solid waste. Among the priorities of Federal Law No. 12305/2010, we highlight the selective collection and socioeconomic inclusion of collectors of recyclable materials that are commonly excluded from the formal labor market, making eminent the development of social technologies for the emancipation of these actors. In this perspective, the present work aims to develop and evaluate the management model in the Malvinas neighborhood, in Campina Grande - PB, under the perspective of social technology. The participatory and experimental research was carried out from March 2016 to November 2017, being carried out in five stages: sensitization and mobilization in environmental education, registration of residents to increase selective collection in th e neighborhood, dissemination of results in event, technological conditions employed by recyclable waste collectors under study, development (innovations) and evaluation of technologies to carry out the management of dry recyclable solid waste in said neighborhood. As a result, the following should be highlighted: Selective collection (20.84%) in the said neighborhood, as well as the development and / or adaptation of four technologies: internal collector (CMRI2) for storage inside the dwellings of the research residents (C8) for the transport of dry recyclable solid waste with dimensions 100x150x150 cm and mobile receivers (R1) for post -sorting waste in dimensions 100x100x100 cm. The positive impacts evidenced through direct observation, reports of recyclable waste collectors in the study and residents of the selective collection were: Increase in the volume of solid waste recycling (48.5%), Income increase (29.07% ), better conditions to the professional practice of material pickers, making possible the sel ective collection. Therefore, the development and application of technological alternatives, based on social technology, favored the integrated management of solid waste, by reducing negative impacts on the environment, as well as, by making feasible the professional practice of collectors of recyclable materials and selective collection in source. / A gestão integrada é um conjunto de ações voltadas para buscar de soluções da problemática oriunda dos resíduos sólidos. Dentre as prioridades da lei federal n° 12305/2010, destaca-se a coleta seletiva e inclusão socioeconômica de catadores de materiais recicláveis que comumente são excluídos de mercado de trabalho formal, tornando eminente o desenvolvimento de tecnologias sociais para emancipação destes atores. Nesta perspectiva, o presente trabalho tem como objetivo, desenvolver e avaliar o modelo de gestão no bairro Malvinas, em Campina Grande – PB, sob a ótica da tecnologia social. A pesquisa participante e experimental foi realizada no período de Março de 2016 a Novembro de 2017, sendo executada em cinco etapas: sensibilização e mobilização em educação ambiental, cadastramento dos moradores para ampliação da coleta seletiva no bairro, divulgação dos resultados em evento, levantamento das condições tecnológicas empregadas pelos catadores de materiais recicláveis em estudo, desenvolvimento (inovações) e avaliação de tecnologias para efetivação da gestão de resíduos sólidos recicláveis secos no referido bairro. Como resultados, destaca-se: A ampliação a coleta seletiva (20,84%) no bairro, bem como, o desenvolvimento e/ou adaptação de quatro tecnologias: coletor interno (CMRI2) para armazenamento no interior das residências dos moradores da pesquisa de dimensões, coletor externo (CMRE2) para armazenamento fora das residências, um veículo desmontável (T8) para transporte de resíduos sólidos recicláveis secos com dimensões 100x150x150 cm e receptores móveis (R1) para os resíduos pós triagem em dimensões 100x100x100 cm. Os impactos positivos evidenciados através da observação direta, relatos dos catadores de materiais recicláveis em estudo e morador praticante da coleta seletiva foram: Aumento no volume da coleta dos resíduos sólidos recicláveis seco (48,5%), Aumento de renda (29,07%), melhores condições ao exercício profissional dos catadores de materiais, viabilizando a coleta seletiva. Portanto, o desenvolvimento e aplicação de alternativas tecnológicas, com base na tecnologia social, favoreceu a gestão integrada de resíduos sólidos, ao reduzir impactos negativos ao meio ambiente, bem como, ao viabilizar o exercício profissional dos catadores de materiais recicláveis e a coleta seletiva na fonte geradora.
|
362 |
Tratamento de lodo em biorreator anaeróbio de membrana dinâmica / Treatment of sludge in anaerobic dynamic membrane bioreactorMelo, Nathália Nunes de 27 February 2018 (has links)
Submitted by Jean Medeiros (jeanletras@uepb.edu.br) on 2018-05-10T14:20:27Z
No. of bitstreams: 1
PDF - Nathália Nunes de Melo.pdf: 18947535 bytes, checksum: 4cfce3961def8f699d9241cbcdbd3859 (MD5) / Made available in DSpace on 2018-05-10T14:20:27Z (GMT). No. of bitstreams: 1
PDF - Nathália Nunes de Melo.pdf: 18947535 bytes, checksum: 4cfce3961def8f699d9241cbcdbd3859 (MD5)
Previous issue date: 2018-02-27 / Conselho Nacional de Desenvolvimento Científico e Tecnológico - CNPq / The treatment of sewage sludge is a challenge for environmental sanitation due to its difficulty to stabilize and large number of undesirable elements. On the other hand, it is found in its composition a high concentration of nutrients that can be reused in the nature in a beneficial way, but that end up being wasted in the conventional treatments. In the present work the treatment of sewage sludge in an anaerobic dynamic membrane bioreactor (AnDMBR) was carried out, in which it was possible to verify that the use of the dynamic membrane provided an excellent performance for the sludge filtration, producing turbidity permeate below 1 NTU after the formation of the separation layer. In addition, 53.2% of the phosphorus concentration and 35.6% of the nitrogen concentration were found in its composition, demonstrating that the use of this technology is a very interesting alternative for the recovery of these nutrients. As long as produced a less pollutant and nutrient-recovering permeate, there was also a marked stabilization of the concentrate, which showed a reduction of the organic fraction from 0.76 to 0.54 and the F/M ratio of 0.07 kgCOD/KgVSS to 0.02 KgCOD/KgVSS, furthermore a considerable methane production was observed. / O tratamento do lodo de esgoto consiste em um desafio na área de saneamento ambiental por se tratar de um resíduo de difícil estabilização e com grande quantidade de elementos indesejáveis. Por outro lado, é encontrada na sua composição uma elevada concentração de nutrientes que podem ser reutilizados na natureza de maneira benéfica, mas que acabam sendo desperdiçados nos tratamentos convencionais. No presente trabalho foi realizado o tratamento do lodo de esgoto em um biorreator anaeróbio de membrana dinâmica (BRAnMD), no qual foi possível verificar que a utilização da membrana dinâmica proporcionou um ótimo desempenho para a filtração do lodo, produzindo um permeado com turbidez abaixo de 1 NTU após o período de formação da camada de separação. Além disso, na sua composição foi encontrada 53,2% da concentração do fósforo afluente e 35,6% da concentração de nitrogênio, demonstrando, dessa forma, que a utilização dessa tecnologia consiste em uma alternativa bastante interessante para a recuperação desses nutrientes. À medida que produzia um permeado menos poluente e recuperava de nutrientes, verificou-se também uma estabilização acentuada do concentrado, que apresentou uma redução da fração orgânica de 0,76 para 0,54 e da relação A/M de 0,07 KgDQO/KgSSV para 0,02 KgDQO/KgSSV além de possibilitar uma considerável produção de metano.
|
363 |
Análise da qualidade da água de poços no enterno de um Açude Urbano em Campina Grande – PBRêgo, Rayssa de Lourdes Carvalho Marinho do 26 February 2018 (has links)
Submitted by Jean Medeiros (jeanletras@uepb.edu.br) on 2018-05-18T13:32:33Z
No. of bitstreams: 1
PDF - Rayssa de Lourdes Carvalho Marinho do Rêgo.pdf: 24283701 bytes, checksum: dc2858efe7d174d11b6aa514f2d92f65 (MD5) / Made available in DSpace on 2018-05-18T13:32:33Z (GMT). No. of bitstreams: 1
PDF - Rayssa de Lourdes Carvalho Marinho do Rêgo.pdf: 24283701 bytes, checksum: dc2858efe7d174d11b6aa514f2d92f65 (MD5)
Previous issue date: 2018-02-26 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / Water is an essential and fundamental resource for the existence of life on Earth, and can be exploited in surface and underground sources. The exploitation of aquifers, for the most part , is a way of "cushioning" the negative impacts generated by water scarcity around the world, however the use of groundwater must meet the quality standards imposed by legislation, such as the Ordinance of the Ministry of Health 2914/2011, when destined for human consumption. The present work aimed to analyze the physico-chemical and microbiological quality of the water from tubular wells located near an urban reservoir in Campina Grande -PB and to emphasize the risks associated to the uses of these waters. To identify the prevailing uses of groundwater in the study area, questionnaires were applied in a statistically significant sample to identify the predominant uses of the study area. The collections occurred in the period from February to August 2017, with the determination of physical-chemical and microbiological indicators of water quality. The sample data set was subjected to descriptive statistical analysis of variance (ANOVA) and the determination of the Pearson coefficients. In general, it was verified that the area of study was predominantly commercial being the main use of groundwater to clean environments, however it is important to evidence the existence of human intake with these groundwater. Users who drank this water used homemade treatments such as chlorine disinfection and boiling water, but according to the physico- chemical and microbiological analyzes performed at point P6, which was groundwater treated with chlorine at home, did not meet the standards imposed by the Ordinance of the Ministry of Health 2914/2011 being improper for human consumption by exceeding the VMP of chloride, fluoride, total dissolved solids-SDT and total coliform microbiological and Escherichia coli. For the physical-chemical and microbiological analysis of raw groundwater, the results also did not comply with the standards of potability, currently in force in Brazil, which according to chloride, fluoride, total dissolved solids and total coliform microbiological indicators and Escherichia coli this water poses a risk to public health if intended for human intake. To this inadequacy, several factors may be related, among them, the contamination of the water table by point sources, such as septic tanks, drainage channels and contaminated water bodies and, in the case of groundwater treated locally and empirically with chlorine, contamination was attributed to the deficiency in cleaning maintenance in the reservoir. / A água é um recurso essencial e fundamental para a existência de vida na Terra, podendo ser explorada em fontes superficiais e subterrâneas. A explotação de aquíferos, em sua maior parte, é uma forma de ―amortecer‖ os impactos negativos gerados pela escassez hídrica em todo o mundo, no entanto o uso das águas subterrâneas deve atender aos padrões de qualidade impostos pela legislação, como a Portaria do Ministério da Saúde 2914/2011, quando destinada ao consumo humano. O presente trabalho objetivou analisar a qualidade físico- química e microbiológica das águas de poços tubulares localizados no entorno de um açude urbano em Campina Grande-PB e enfatizar os riscos associados aos usos dessas águas. Para identificar os usos preponderantes das águas subterrâneas na área de estudo, foi aplicado questionários em uma amostra estatisticamente significante visando identificar os usos preponderantes da área de estudo. As coletas ocorreram no período de fevereiro a agosto de 2017, com a determinação de indicadores físico-químicos e microbiológicos da qualidade da água. O conjunto de dados amostrais foi submetido à análise estatística descritiva, de variância (ANOVA) e a determinação dos coeficientes de Pearson. De um modo geral, foi verificado que a área de estudo era preponderantemente comercial sendo o principal uso das águas subterrâneas a limpeza de ambientes, no entanto é importante evidenciar a existência de ingestão humana com essas águas subterrâneas. Os usuários que bebiam essa água, faziam a utilização de tratamentos caseiros como a desinfecção com cloro e à fervura de água, porém de acordo com as análises físico-química e microbiológica realizada no ponto P6, que foi a água subterrânea tratada com cloro caseiramente, não atendeu aos padrões impostos pela Portaria do Ministério da saúde 2914/2011 sendo impropria para o consumo humano por ultrapassarem o VMP dos indicadores cloreto, fluoreto, sólidos dissolvidos totais- SDT e das análises microbiológicas coliformes totais e Escherichia coli. Para a análise físico-química e microbiológica das águas subterrâneas brutas os resultados também não apresentaram conformidade com os padrões de potabilidade, ora em vigor no Brasil, que de acordo com os indicadores cloreto, fluoreto, sólidos totais dissolvidos e os microbiológicos coliformes totais e Escherichia coli essa água representa risco a saúde pública se destinadas a ingestão humana. A essa inadequação, vários fatores podem estar relacionados, dentre os quais a contaminação do lençol freático por fontes pontuais, como fossas sépticas, canais de drenagem e corpos hídricos contaminados e, no caso da água subterrânea tratada local e empiricamente, com cloro, a contaminação foi atribuída à deficiência na manutenção de limpeza no reservatório.
|
364 |
Validação de método para determinação de ácidos graxos voláteis em efluentes de biorreatores anaeróbios através de cromatografia gasosaRodrigues, Roberta Milena Moura 19 June 2017 (has links)
Submitted by Jean Medeiros (jeanletras@uepb.edu.br) on 2018-05-18T14:20:50Z
No. of bitstreams: 1
PDF - Roberta Milena Moura Rodrigues.pdf: 36710948 bytes, checksum: 554ab863304bbf43e3ca861642fc5611 (MD5) / Made available in DSpace on 2018-05-18T14:20:51Z (GMT). No. of bitstreams: 1
PDF - Roberta Milena Moura Rodrigues.pdf: 36710948 bytes, checksum: 554ab863304bbf43e3ca861642fc5611 (MD5)
Previous issue date: 2017-06-19 / onselho Nacional de Desenvolvimento Científico e Tecnológico - CNPq / Secondary biological anaerobic processes used for wastewater treatment have developed rapidly since the mid-20th century and are currently used in most Sewage Treatment Plants (ETEs) around the world. Sludge produced throughout the treatment is the main byproduct and is a semi-solid material containing organic matter, pathogenic microorganisms, toxic substances and even heavy metals withdrawn from the liquid phase. However, by applying appropriate treatment, it can transform itself from a problem residue into a product with economic value: modern and low-cost technologies can be reused in the material (nutrients and heavy metals) and its energy potential (biogas production - 70% methane). Volatile fatty acids (AGVs) are important intermediates of anaerobic digestion and their rate of production largely determines the rate of methane production. The knowledge of the concentration of VFAs in the sludge under treatment allows monitoring the performance of the reactor. The gas chromatography coupled to mass spectrometry (GC / MS), for the determination of VFAs, stands out from others for being efficient and selective, and allows structural information, molar mass, among other advantages. The validation of a method for its detection ensures the reliability of the results. In the present work, the Thermo Scientific gas chromatograph (TRACE 1300) was used and the detector was a Thermo Scientific mass spectrometer (ISQ QD - Single Quadrupole) with an SPB-624 intermediate polarity column. Recognized brand reagents And previous tests were done to define suitable conditions for the method (CG / MS). Validation was done following the recommendations of INMETRO and ANVISA. The results showed that the validation of the method (GC / MS) for determination of VFAs with the chosen column and the best chromatographic conditions obtained were adequate, taking into account the validation parameters: linearity (r ≥ 0,9843), precision Coefficients of variation <20%), sensitivity (angular coefficients ≥ 238218), limit of detection (0.030 mg.L-1 - 0.848 mg.L-1), limit of quantification (0.120 mg.L-1 - 2.827 mg.L -1), accuracy (100% - 110% - higher concentrations). Applied to real matrices, the method proved to be satisfactory because the retention times were very similar to the patterns used. / Processos biológicos secundários anaeróbios empregados para o tratamento de águas residuais têm se desenvolvidos de forma acelerada a partir da metade do século XX e são atualmente utilizados na maioria das Estações de Tratamento de Esgotos (ETEs) ao redor do mundo. Lodos produzidos ao longo do tratamento são o principal subproduto e constituem um material semisólido que contem matéria orgânica, microrganismos patogênicos, substâncias tóxicas e até metais pesados retirados da fase líquida. Entretanto, aplicando-se tratamento adequado, pode se transformar de um resíduo problema em um produto com valor econômico: tecnologias modernas e de baixo custo podem ser reaproveitados materiais nele contido (nutrientes e metais pesados) e pelo seu potencial energético (produção de biogás - 70% de metano). Os ácidos graxos voláteis (AGVs) são importantes intermediários da digestão anaeróbia e sua taxa de produção determina em grande parte a taxa de produção de metano. O conhecimento da concentração de AGVs no lodo em tratamento permite acompanhar o desempenho do reator. O método de cromatografia gasosa acoplada à espectrometria de massas (CG/EM), para determinação de AGVs, se destaca de outros por ser eficiente e seletivo, e permite obter informação estrutural, massa molar, entre outras vantagens. A validação de um método para sua detecção assegura a confiança dos resultados. No presente trabalho foi utilizado o cromatógrafo gasoso Thermo Scientific (TRACE 1300) e o detector foi um espectrômetro de massas Thermo Scientific (ISQ QD – Single Quadrupole) com uma coluna de polaridade intermediária SPB- 624. Foram utilizados reagentes (analitos) de marca reconhecida e testes prévios foram feitos para definir condições adequadas para o método (CG/EM). A validação do mesmo foi realizada seguindo as recomendações de INMETRO e ANVISA. Os resultados mostraram que a validação do método (CG/EM) para determinação de AGVs com a coluna escolhida e as melhores condições cromatográficas obtidas mostraram-se adequadas, atendendo aos parâmetros de validação: linearidade (r ≥ 0,9843), precisão (coeficientes de variação < 20%), sensibilidade (coeficientes angulares ≥ 238218), limite de detecção (0,030 mg.L-1 - 0.848 mg.L-1) , limite de quantificação (0.120 mg.L-1 - 2.827 mg.L -1), exatidão (100% - 110% - concentrações maiores). Aplicado em matrizes reais o método se mostrou satisfatório porque os tempos de retenção foram muito semelhantes aos dos padrões utilizados.
|
365 |
Dinâmica da comunidade fitoplanctônica em dois estuários tropicais sujeitos a diferentes usos do solo: Estuários Paraíba e MamanguapeSantana, Rosa Maria da Costa 15 February 2018 (has links)
Submitted by Jean Medeiros (jeanletras@uepb.edu.br) on 2018-06-15T13:08:14Z
No. of bitstreams: 1
PDF - Rosa Maria da Costa Santana.pdf: 51961570 bytes, checksum: 5a2038497b3a26e2cb0310104f961367 (MD5) / Approved for entry into archive by Secta BC (secta.csu.bc@uepb.edu.br) on 2018-06-18T18:13:01Z (GMT) No. of bitstreams: 1
PDF - Rosa Maria da Costa Santana.pdf: 51961570 bytes, checksum: 5a2038497b3a26e2cb0310104f961367 (MD5) / Made available in DSpace on 2018-06-18T18:13:01Z (GMT). No. of bitstreams: 1
PDF - Rosa Maria da Costa Santana.pdf: 51961570 bytes, checksum: 5a2038497b3a26e2cb0310104f961367 (MD5)
Previous issue date: 2018-02-15 / The phytoplankton community is composed of microorganisms that are excellent environmental bioindicators, since they respond quickly to environmental disturbances. In this sense, the study aimed to apply diversity indexes (taxonomic and functional), as well as to explore the functional groups along the environmental gradients of two estuaries (Paraíba and Mamanguape) in two seasonal periods (dry = November/2013 and wet = July/2014) and to relate to the physical and chemical variables of water, in order to understand how this community responds to the different environmental and seasonal conditions. Thus, in the 1st chapter, the taxonomy of the Chlorophyta group was verified, since this group was the second most representative in this study. In estuarine environments, these green algae are common in low salinity, especially in periods of less rainfall and in the upstream segments. Twelve taxa were divided into two classes, three orders and 11 genera. In the 2nd chapter we compare the phytoplankton community's responses in terms of structure (abundance, richness and diversity) in relation to the environmental variables in estuaries with different uses and occupation of the soil. Biomass and abundance were higher when nutrient loads were higher, contributing to low diversity and dominance of the species Cyclotella meneghiniana, Thalassionema nitzschioides and Thalassiosira gravida associated to the different degrees of impacts observed in both ecosystems and seasonal periods. In the 3rd chapter, functional complementarity (CWM), redundancy and functional composition indexes (functional richness, functional diversity and quadratic entropy of RAO) were analyzed through functional groups based on combinations of different traits. In both systems, the main dominant functional group was diatoms, characterized by lack of mobility and high sink rates due to siliceous walls, including small and larger individuals, and freshwater to more cosmopolitan species. The presence of this group and the change in the categories of traces along the spatial and seasonal gradient were associated with the environmental condition, for example, river flow, low light conditions and changes in salinity. Overall, this study combining different approaches to taxonomic and functional diversity has improved our understanding of the changes occurring in both estuaries, pointing to efforts that should be directed towards more effective conservation measures that can be used in conservation programs systems. / A comunidade fitoplanctônica é composta por microorganismos que são excelentes bioindicadores ambientais, uma vez que respondem rapidamente às perturbações ambientais. Nesse sentido, o estudo objetivou aplicar índices de diversidade (taxonômico e funcional), como também explorar os grupos funcionais ao longo dos gradientes ambientais de dois estuários (Paraíba e Mamanguape), em dois períodos sazonais (seco = novembro/2013 e chuvoso = julho/2014) e relacionar com as variáveis físicas e químicas da água, visando compreender como essa comunidade responde às diferentes condições ambientais e sazonais. Assim, no 1°capítulo foi verificado a taxonomia relativa ao grupo das Chlorophytas, uma vez que esse grupo foi o segundo mais representativo nesse estudo. Em ambientes estuarinos, essas algas verdes são comuns em baixa salinidade, principalmente, em períodos de menos chuvas e nos segmentos mais a montante. Foram identificados 12 taxa distribuídos em duas classes, três ordens e 11 gêneros. No 2° capítulo comparamos as respostas da comunidade fitoplanctônica em termos de estrutura (abundância, riqueza e diversidade) em relação às variáveis ambientais em estuários com diferentes usos e ocupação do solo. A biomassa e abundância foram superiores quando as cargas de nutrientes estiveram mais elevadas, contribuindo para uma baixa diversidade e dominância da espécie Cyclotella meneghiniana, Thalassionema nitzschioides e Thalassiosira gravida associadas aos diferentes graus de impactos observados nos dois ecossistemas e aos períodos sazonais. No 3° capítulo foram avaliados índices de complementaridade funcional (CWM), redundância e composição funcional (riqueza funcional, diversidade funcional e entropia quadrática de RAO) analisados através de grupos funcionais baseados em combinações de diferentes traços. Em ambos os sistemas, o principal grupo funcional dominante foi o das diatomáceas, caracterizadas pela falta de mobilidade e altas taxas de afundamento devido às paredes silicosas, e incluindo indivíduos pequenos e maiores, e de água doce a espécies mais cosmopolitas. A presença deste grupo e a mudança nas categorias de traços ao longo do gradiente espacial e sazonalmente foram associadas à condição ambiental, por exemplo, escoamento do rio, condições de pouca luz e mudanças de salinidade. No geral, este estudo combinando diferentes abordagens de diversidade taxonômica e funcional, permitiu melhorar nossa compreensão das mudanças que ocorrem em ambos os estuários, apontando para esforços que devem ser dirigidos em relação à medidas de conservação mais eficazes e que podem ser utilizados em programas de monitoramento desses sistemas.
|
366 |
Restauração de água eutrofizadas do semiárido brasileiro através da técnica Flock & LockSilva, Daniely de Lucena 31 August 2018 (has links)
Submitted by Jean Medeiros (jeanletras@uepb.edu.br) on 2018-10-23T13:26:36Z
No. of bitstreams: 1
PDF - Daniely de Lucena Silva.pdf: 19787731 bytes, checksum: 4876e7607977a002cf59f1f8d2f5d9a8 (MD5) / Made available in DSpace on 2018-10-23T13:26:36Z (GMT). No. of bitstreams: 1
PDF - Daniely de Lucena Silva.pdf: 19787731 bytes, checksum: 4876e7607977a002cf59f1f8d2f5d9a8 (MD5)
Previous issue date: 2018-08-31 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / The Flock & Lock technique was indicated as one of the best alternatives for the recovery of eutrophicated lakes and reservoirs. This is a series of applications of flocculants (Flock) and clays (Lock) to flocculate / sediment and inactive, respectively, the phosphorus of the water column. The present study evaluated the efficiency of aluminum sulphate (SUL), alkali polychloride (PAC) and chitosan (QUI) flocculants, isolated and combined with natutal (BEN) and lanthanum modified bentonite (BML) eutrophic dust from the Brazilian semiarid, as well as the beneficial effects on cyanobacteria density and the intra and extracellular forms of cyanotoxins. Bench scale tests using water samples from the Argemiro Figueiredo reservoir, located in the municipality of Itatuba, Paraíba, Brazil. These tests were conducted in glass beakers containing 200 mL of water from the reservoir, samples being collected at the top and bottom of the beakers. Cyanobacteria density was determined by inverted microscope and the intra and extracellular concentrations of the cyanotoxins microcystin, saxitoxin and cylindrospermopsin by the Enzyme-Linked Immuno Sorbent Assay (ELISA) method. Analysis of one-way variance (ANOVA one-way) was performed to verify significant differences between treatments. It was observed that the SUL and PAC flocculants efficiently reduced the PT, PSR, turbidity, chlorophyll-a, cyanobacteria density and intracellular microcystin efficiency, whereas the chitosan showed low removal power of the evaluated parameters. The BML showed to be more efficient than the BEN, however, the application of these clays combined with the flocculants was not strictly necessary in the success of the Flock & Lock technique, since the SUL and PAC alone proved to be sufficient in the significant removal of the parameters studied. The efficiency of flocculants in the removal of cyanobacteria cells varied between species. Small-sized species such as A. delicatissima, M. glauca and M. tenuissima were effectively removed regardless of treatment, including those with QUI and BEN, while filamentous cyanobacteria C. raciborskii, G. amphibium, P. agardhii and P. Catenata were removed only with the application of PAC, SUL and BML isolated and combined. The intracellular concentrations of saxitoxin and cylindrospermopsin and the extracellular fraction of these cyanotoxins and microcystin were not influenced by the application of flocculants and clays. These results show that cyanotoxin types differ in the response to these compounds and that the successful application of the Flock & Lock technique in the recovery of eutrophic lakes and reservoirs can be compromised in bodies of water with high concentration of dissolved toxins. / A técnica Flock & Lock tem sido indicada como uma das melhores alternativas na recuperação de lagos e reservatórios eutrofizados. Essa técnica consiste na aplicação de floculantes (Flock) e argilas (Lock) para flocular/sedimentar e inativar, respectivamente, o fósforo da coluna d‟água. O objetivo do presente estudo foi avaliar a eficiência dos floculantes sulfato de alumínio (SUL), policloreto de alimínio (PAC) e quitosana (QUI), isolados e combinados com argilas betonita natutal (BEN) e bentonita modificada com lantânio (BML), na remoção do P em águas eutrofizadas do semiárido brasileiro, bem como verificar os efeitos desses compostos sobre a densidade das cianobactérias e as concentrações intra e extracelular das cianotoxinas. Ensaios em escala de bancada foram realizados utilizando amostras da água do reservatório Argemiro Figueiredo, localizado no município de Itatuba, Paraíba, Brasil. Esses ensaios foram conduzidos em provetas de vidro contendo 200 mL da água do reservatório, sendo coletadas amostras no topo e fundo das provetas. A densidade das cianobactérias foi determinada em microscópio invertido e as concentrações de intra e extracelular das cianotoxinas microcistina, saxitoxina e cilindrospermopsina pelo método Enzyme-Linked Immuno Sorbent Assay (ELISA). A análise de variância um fator (ANOVA um fator) foi realizada para verificar as diferenças significativas entre os tratamentos. Foi observado que os floculantes SUL e PAC reduziram eficientemente da coluna d‟água o PT, PSR, turbidez, clorofila-a, densidade das cianobactérias e microcistina intracelular, enquanto a quitosana mostrou baixo poder de remoção dos parâmetros avaliados. A BML mostrou ter maior eficiência que a BEN, no entanto, a aplicação dessas argilas combinadas com os floculantes mostrou não ser estritamente necessária no sucesso da técnica Flock & Lock, uma vez que o SUL e PAC sozinhos mostraram ser suficientes na remoção significativa dos parâmetros estudados. A eficiência dos floculantes na remoção das células das cianobactérias variou entre as espécies. As espécies de pequeno tamanho como A. delicatissima, M. glauca e M. tenuissima foram eficazmente removidas independente do tratamento, incluindo aqueles com a QUI e a BEN, enquanto as cianobactérias filamentosas C. raciborskii, G. amphibium, P. agardhii e P. catenata foram removidas apenas com a aplicação do PAC, SUL e BML isolados e combinados. As concentrações intracelulares da saxitoxina e cilindrospermopsina e a fração extracelular dessas cianotoxinas e da microcistina não foram influenciadas pela aplicação dos floculantes e argilas. Esses resultados mostram que os tipos de cianotoxinas diferem na resposta a esses compostos e que o sucesso da aplicação da técnica Flock & Lock na recuperação de lagos e reservatórios eutrofizados pode ser comprometida em corpos d‟água com alta concentração de toxinas dissolvidas.
|
367 |
Viabilidade econÃmica do aproveitamento do biogÃs de pequenos aterros sanitÃrios na reciclagem de plÃstico / Economic viability of small landfill biogas exploitation in plastic recyclingFernando Henrique Ribeiro Holanda 06 June 2014 (has links)
CoordenaÃÃo de AperfeÃoamento de Pessoal de NÃvel Superior / A geraÃÃo de resÃduos sÃlidos faz parte do contexto social em que vivemos, entretanto, a cultura da reciclagem ainda à pouco valorizada no Brasil. A PolÃtica Nacional de ResÃduos SÃlidos, de 2010, estimula a valorizaÃÃo do processo de reciclagem, da organizaÃÃo e do fim da informalidade dos catadores, alÃm de incentivar o aproveitamento energÃtico do biogÃs gerado em aterros sanitÃrios. Fundamentado nesses trÃs pontos, o presente trabalho elaborou um plano de negÃcios para a implantaÃÃo de uma usina de reciclagem de plÃstico Polietileno de Alta Densidadeâ PEAD, utilizando, para tanto, a energia produzida pelo biogÃs no Aterro SanitÃrio Metropolitano Sul em MaracanaÃ, CearÃ. Foram desenvolvidos projetos de coleta e aproveitamento do biogÃs e de uma usina de processamento de PEAD, alÃm de levantamento de custos de todo o material necessÃrio para a implantaÃÃo e operaÃÃo da planta. Analisou-se a viabilidade econÃmica de dois ambientes distintos, pela Cooperativa de catadores e pela Empresa de reciclagem. Para cada ambiente, foram desenvolvidos trÃs cenÃrios de aquisiÃÃo do material plÃstico (100% comprado, 50% comprado e 50% doado, 100% doado). Foi possÃvel constatar que apenas o ambiente Cooperativa e o terceiro cenÃrio mostraram-se sustentÃveis para a implantaÃÃo de um sistema deste porte. / A geraÃÃo de resÃduos sÃlidos faz parte do contexto social em que vivemos, entretanto, a cultura da reciclagem ainda à pouco valorizada no Brasil. A PolÃtica Nacional de ResÃduos SÃlidos, de 2010, estimula a valorizaÃÃo do processo de reciclagem, da organizaÃÃo e do fim da informalidade dos catadores, alÃm de incentivar o aproveitamento energÃtico do biogÃs gerado em aterros sanitÃrios. Fundamentado nesses trÃs pontos, o presente trabalho elaborou um plano de negÃcios para a implantaÃÃo de uma usina de reciclagem de plÃstico Polietileno de Alta Densidadeâ PEAD, utilizando, para tanto, a energia produzida pelo biogÃs no Aterro SanitÃrio Metropolitano Sul em MaracanaÃ, CearÃ. Foram desenvolvidos projetos de coleta e aproveitamento do biogÃs e de uma usina de processamento de PEAD, alÃm de levantamento de custos de todo o material necessÃrio para a implantaÃÃo e operaÃÃo da planta. Analisou-se a viabilidade econÃmica de dois ambientes distintos, pela Cooperativa de catadores e pela Empresa de reciclagem. Para cada ambiente, foram desenvolvidos trÃs cenÃrios de aquisiÃÃo do material plÃstico (100% comprado, 50% comprado e 50% doado, 100% doado). Foi possÃvel constatar que apenas o ambiente Cooperativa e o terceiro cenÃrio mostraram-se sustentÃveis para a implantaÃÃo de um sistema deste porte. / The generation of solid waste is part of the social context in which we live , however, the culture of recycling is still undervalued in Brazil . The 2010 National Solid Waste Policy encourages the improvement of recycling process, the organization of waste pickers to end informal activities, and encourages the use of biogas generated in landfills. Based on these three topics, this paper drew up a business plan for a recycling plant for HDPE using the biogas energy produced in the South Metropolitan Landfill in Maracanau, CearÃ. For this, a biogas collection system and a plant for HDPE processing were developed in addition costs estimates of all the material needed for their implementation and operation. It was analyzed the economic feasibility for two distinct environments, using the waste pickers Cooperative and through a regular recycling company. For each environment, three raw material acquisition scenarios were developed (100% purchased, 50 % purchased and 50% donated, and 100 % donated ). It was found that only with the cooperative environment and in the third scenario the business proved to be economically feasible. / The generation of solid waste is part of the social context in which we live, however, the culture of recycling is still undervalued in Brazil. The National Solid Waste Policy, 2010, encourages the enhancement of the recycling process, the organization and the end of the informal waste pickers, and encourage the energy use of biogas generated in landfills. Based on these three points, this study developed a business plan for the deployment of a plastic recycling plant in High Density Polyethylene HDPE, using for this purpose, the energy produced by biogas in South Metropolitan Landfill in Marazion, CearÃ. Were developed collection of projects and use of biogas and a HDPE processing plant, as well as raising costs of all the material necessary for the implementation and operation of the plant. We analyzed the economic feasibility of two different environments, by the Cooperative pickers and recycling by the Company. For each environment, were developed three scenarios for the acquisition of the plastic material (100% purchased, 50% purchased and donated 50%, 100% donated). It was found that only the cooperative environment and the third scenario proven to be sustainable for the implementation of a system of this size.
|
368 |
Qualidade da água dos reservatórios situados na bacia hidrográfica dos rios Piauí – Real : uma avaliação com base em técnicas estatísticas multivariadas e razões iônicasLima, Robson Silva de 31 March 2015 (has links)
In this work the quality of the water and its variations were evaluated for the Dionísio Machado (DM), Taboca (TB), Amargosa (AG) and Jabiberi (JB) reservoirs, located in the South Central region of the State of Sergipe. Surface water samples were collected in three sampling campaigns, two in the rainy season and one in the dry period, included between June 2013 and August 2014. In each sample the following parameters were determined: pH, electric conductivity, turbidity, dissolved oxygen, total alkalinity, hardness, biochemical oxygen demand, total dissolved solids, colour, total organic carbon, total phosphorus, nitrate, nitrite, ammoniacal nitrogen, phosphate, sodium, potassium, calcium, magnesium, chloride, sulphate, bicarbonate, thermotolerant coliforms and temperature. The principal component analysis, correlation analysis Spearman and cluster analysis were applied to all data, in order to compare the standard quality of the water between reservoirs and to obtain information about the differences between the dry and rainy seasons on the variables involved in discrimination and their origin sources. To the Dionísio and Taboca reservoirs, the samples collected during the rainy season of 2014 showed similarity to those collected in the 2013 dry season and difference from samples collected in the rainy season of 2013. While for Jabiberi reservoir, all samples were similar, no difference was observed in the dry and rainy period. The sample of Amargosa showed no similarity to any sample of the remaining reservoirs and it could not be verified a seasonal variation, since for this reservoir, a single sample was collected in the rainy season of 2013. Through the principal component analysis, we found that the salinization is the main process that explains the variations in the quality of the water in the reservoirs. The electrical conductivity of the samples ranged from 0.160 to 4.175 dS m-1, showing a growing process of salinization, reaching a maximum value in the Amargosa reservoir. Through the ionic fractions it was possible to infer that the main factors that control the process of the reservoir water salinity are of natural origin and are associated with the cation exchange reactions and subsequent dissolution of soluble minerals such as halite, gypsum and possibly epsomita. / Nesse trabalho foram avaliadas a qualidade da água e suas variações, para os reservatórios Dionísio Machado (DM), Tabocas (TB), Amargosa (AG) e Jabiberi (JB), situados na região Centro Sul do Estado de Sergipe. Amostras de água de superfície foram coletadas em três campanhas de amostragem, duas no período chuvoso e uma no período seco, compreendidas no intervalo temporal de junho de 2013 a agosto de 2014. Em cada amostra foram determinados os seguintes parâmetros: pH, condutividade elétrica, turbidez, oxigênio dissolvido, alcalinidade total, dureza, demanda bioquímica de oxigênio, sólidos totais dissolvidos, cor, carbono orgânico total, fosfato, fósforo total, nitrato, nitrito, nitrogênio amoniacal, sódio, potássio, cálcio, magnésio, cloreto, sulfato, bicarbonato, coliformes termotolerantes e temperatura. A análise de componentes principais, a análise de correlação de Spearman e a análise de agrupamento foram aplicadas ao conjunto dos dados, com objetivo de comparar o padrão de qualidade da água entre os reservatórios e obter informações sobre as diferenças entre os períodos seco e chuvoso, sobre as variáveis envolvidas na discriminação e as fontes que a originaram. As amostras coletadas no período chuvoso de 2014 mostraram similaridade com as amostras coletadas no período seco de 2013 e diferentes das amostras coletadas no período chuvoso de 2013, para os reservatórios de Taboca e Dionísio. Enquanto que para o reservatório de Jabiberi, todas as amostras foram similares, não se observando diferença em relação ao período seco e chuvoso. A amostra de Amargosa não mostrou similaridade com nenhuma amostra dos outros reservatórios e não foi possível verificar variação com a sazonalidade, pois, para esse reservatório, foi coletada uma única amostra no período chuvoso de 2013. Pela análise de componentes principais foi possível identificar que a salinização é o principal processo que explica as variações na qualidade da água dos reservatórios. A condutividade elétrica das amostras variou de 0,160 a 4,175 dS m-1, mostrando um processo crescente de salinização, atingindo um valor máximo no reservatório de Amargosa. Através das razões iônicas foi possível inferir que os principais fatores que controlam o processo de salinização da água dos reservatórios são de origem natural e estão associados às reações de troca catiônica e posterior dissolução de minerais solúveis como halita, gipsita e possivelmente epsomita.
|
369 |
Tratamento do lodo de resíduos de fossas e tanques sépticos em um sistema de alagado construído / Septic tanks and cesspools residues sludge treatment at a constructed wetlands systemSilva Junior, Édio Damásio da 13 November 2013 (has links)
Submitted by Erika Demachki (erikademachki@gmail.com) on 2014-10-23T16:36:45Z
No. of bitstreams: 2
Dissertação - Édio Damásio da Silva Junior - 2013.pdf: 3273647 bytes, checksum: 8b91152a8caeed706b4e8d78ff9facc0 (MD5)
license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Approved for entry into archive by Jaqueline Silva (jtas29@gmail.com) on 2014-10-23T18:07:43Z (GMT) No. of bitstreams: 2
Dissertação - Édio Damásio da Silva Junior - 2013.pdf: 3273647 bytes, checksum: 8b91152a8caeed706b4e8d78ff9facc0 (MD5)
license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Made available in DSpace on 2014-10-23T18:07:43Z (GMT). No. of bitstreams: 2
Dissertação - Édio Damásio da Silva Junior - 2013.pdf: 3273647 bytes, checksum: 8b91152a8caeed706b4e8d78ff9facc0 (MD5)
license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5)
Previous issue date: 2013-11-13 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / The use of individual systems for treatment and disposal of sewage (ISTDS) comes as an option to the lack of sanitation in many Brazilian regions, mainly in small settlements. However, the wastes generated in these systems represent another health problem, since it contains high levels of pathogens and organic load. These wastes, termed septic tanks and cesspools residues (STCR) must be treated before their disposal to the environment. Simple and low cost technologies, like the constructed wetlands systems (CW), should be developed and evaluated aiming its implementation in small population centers. This study aimed to evaluate the treatment, more specifically the cleaning and stabilization, of the sludge accumulated in a CW designed to treat STCR. Two tanks were constructed, dug into the ground and filled with overlapping layers of gravel and sand for application and treatment of the STCR. One of them was grown by the vegetal specie Vetiver Grass (Chrysopogon zizanioides) and the other one was used as a control treatment. The STCR were applied to the system by the exhaustion of clean-pit trucks. The system behaved in vertical downward subsurface flow, controlled by a fluid spilling system. Physical-chemical and microbiological analyses of the crude residue and sludge in treatment in both tanks were made. The STCR nutritional potential was characterized through the determination of total phosphorus, total, organic and ammonia nitrogen, nitrite and nitrate. Their pathogen load was characterized by counting total coliforms, Escherichia coli, Salmonella spp. and helminths viable eggs. In addition, were characterized the attributes pH, moisture, total, volatile and fixed solids. From the sludge accumulated on the surface of treatment beds they were evaluated its pathogen load, solids content and moisture. The results were compared with the established pursuant to resolution nº 375/2006, of the brazilian National Council for the Environment (CONAMA), to verify the possibility of the sludge use in agriculture. The crude residue characterization results, showed to be similar to those cited by the literature, with high concentrations of pathogens and nutrients and also, high dispersion of values. With STCR disposals, the sludge layer increased in both systems, with higher values for the CW (about 1.1 cm per month), because of their greater capacity to retain moisture. During the disposal phase, both tanks sludge remained with high values of pathogenic organisms. At the end of the applications, there has been considerable reduction of these values, suggesting that for a better sludge treatment should be a period of "rest" without applications. It was observed that after two months of "rest", the sludge from both tanks was framed in A Class, with potential use in agriculture, as standardizes the resolution nº 375/2006 of CONAMA. In general, the tank without plants showed greater speed in the process of cleaning the sludge than the CW, mainly due to the direct sunlight exposure. However, with respect to the stabilization process, the CW was better than the control tank. / A utilização de sistemas individuais de tratamento e disposição de esgoto (SITDE) constitui-se em opção à carência de saneamento básico em diversas regiões brasileiras, principalmente em pequenos núcleos populacionais. Todavia, os resíduos esgotados nestes sistemas representam novo problema sanitário, uma vez que contém elevados teores de organismos patogênicos e de carga orgânica. Estes resíduos, denominados de resíduos de fossas e tanques sépticos (RFTS), devem ser tratados antes de sua disposição no meio ambiente. Tecnologias simples e de baixos custos, como os sistemas de alagados construídos (SAC’s), devem ser desenvolvidas e pesquisadas visando sua implantação em pequenos núcleos populacionais. Este trabalho objetivou avaliar o tratamento, mais especificamente a higienização e estabilização, do lodo acumulado em um SAC projetado para tratamento de RFTS. Foram construídos dois tanques, escavados no solo e preenchidos com camadas sobrepostas de brita e areia para aplicação e tratamento dos RFTS. Um tanque foi cultivado com a espécie vegetal Capim Vetiver (Chrysopogon zizanioides) e o outro serviu de testemunha. Os RFTS foram aplicados através do esgotamento de caminhões limpa-fossa. O sistema comportou-se em fluxo subsuperficial vertical descendente, controlado por um sistema de extravazão de líquidos. Foram realizadas análises físico-químicas e microbiológicas do resíduo bruto e do lodo em tratamento de ambos os tanques. Caracterizou-se o potencial nutricional do RFTS por meio da determinação das concentrações de fósforo total, nitrogênio total, orgânico e amoniacal, nitrito e nitrato. A carga de patógenos foi obtida por meio da contagem de coliformes totais, Escherichia coli, Salmonella spp. e ovos viáveis de helmintos. Também foram caracterizados os atributos pH, umidade, sólidos totais, fixos e voláteis. Do lodo acumulado na superfície dos leitos de tratamento avaliaram-se a carga patógena, o teor de sólidos e a umidade. Os resultados foram comparados com o estabelecido pela resolução nº 375/2006, do Conselho Nacional de Meio Ambiente (CONAMA), para verificar sua potencialidade de uso agrícola. A caracterização do resíduo bruto apresentou dados similares à literatura, com elevadas concentrações de patógenos e nutrientes, além da alta dispersão de resultados. Com as disposições do RFTS, a camada de lodo aumentou em ambos os sistemas, com valores superiores para o SAC (cerca de 1,1 cm ao mês), em virtude de sua maior capacidade de retenção de umidade. Durante a fase de aplicação dos resíduos, o lodo de ambos os tanques permaneceu com altos valores de organismos patógenos. Ao cessar as aplicações, houve considerável redução destes valores, sugerindo que para melhor tratamento do lodo deve-se haver um período de “descanso”, sem aplicações. Observou-se que após um período de dois meses de “descanso”, o lodo de ambos os tanques foi enquadrado na classe A, com possibilidade de uso na agricultura, conforme normatiza o CONAMA. De forma geral, o tanque sem plantas apresentou maior rapidez no processo de higienização do lodo do que no SAC, principalmente em função da exposição solar direta. Entretanto, no que tange ao processo de estabilização, o SAC foi superior ao tanque controle.
|
370 |
Disposição de efluente de tratamento de esgoto industrial em solo vegetado com bambu / Industrial sewage treatment effluent disposal in soil vegetated with bambooMENDONÇA, Eurivan Alves 31 August 2010 (has links)
Made available in DSpace on 2014-07-29T15:01:44Z (GMT). No. of bitstreams: 1
Dissertacao Eurivan A Mendonca 2010.pdf: 356252 bytes, checksum: 182f4d4d579221f0db2469404dd75fd2 (MD5)
Previous issue date: 2010-08-31 / This study aimed to evaluate the efficiency of the bamboo species Guadua angustifolia Kunth, Guadua chacoensis and Dendrocalamus giganteus Munro in the treatment of the Senador Canedo Industrial District Sewer Treatment effluent. It was analyzed diary effluent slides of 176.8, 212.2, 247.6 and 353.7 mm applied in individual 200 L drums filled with regional soil (oxisoil) and vegetated with bamboo. Drums without plants served as control. The effluent treated by the containers was analyzed for biochemical oxygen demand
(BOD), dissolved oxygen, chemical oxygen demand (COD), apparent color, pH, ammonium nitrogen, phosphates, turbidity, chlorides, hardness, electrical conductivity, total solids, dissolved total solids, volatile total solids, fixed total solids and coliforms, during a five month period. The results were analyzed by Statistical Analysis System Program (SAS)
through F test and Tukey-Kramer test (5% of probability). Treatment using bamboo were more efficient than control in removing BOD, COD, pH, dissolved oxygen, apparent color,
total solids, fixed solids, coliforms, chlorides, turbidity, electrical conductivity, phosphates and ammonium nitrogen. Among vegetated drums, bamboos of Guadua gender were more efficient in removing BOD, COD, coliforms and volatile solids than units with D. giganteus. Application rates had no significant influence on treatment efficiencies. It was also evaluated the bamboo species under field conditions, submitted to a diary effluent slide of 353.7 mm for a period of one year. Samples of groundwater were collected to verify some resultant contamination from the effluent application. It wasn t observed groundwater contamination by applying effluent at soil vegetated with bamboo. / Este estudo objetivou avaliar a eficiência das espécies de bambu Guadua angustifolia Kunth, Guadua chacoensis e Dendrocalamus giganteus Munro, no tratamento do efluente da estação de tratamento de esgotos do Distrito Industrial de Senador Canedo, GO. Analisou-se a aplicação das lâminas diárias de efluente de 176,8; 212,2; 247,6 e 353,7 mm em
tambores individuais de 200 Litros preenchidos com solo da região (latossolo vermelho distrófico) e vegetados com bambu. Tambores sem plantas serviram de testemunhas. O
efluente tratado nos tambores foi analisado quanto à demanda bioquímica de oxigênio (DBO), oxigênio dissolvido, demanda química de oxigênio (DQO), cor aparente, pH, nitrogênio amoniacal, fosfatos, turbidez, cloretos, dureza, condutividade elétrica, sólidos totais, sólidos totais dissolvidos, sólidos totais voláteis, sólidos totais fixos e coliformes termotolerantes, por um período de cinco meses. Os resultados foram submetidos aos testes F e de Tukey-Kramer (5% de probabilidade). Os tratamentos com bambu foram mais eficientes na remoção dos parâmetros DBO, DQO, pH, oxigênio dissolvido, cor, sólidos totais, sólidos fixos, coliformes termotolerantes, cloretos, turbidez, condutividade elétrica, fosfatos e nitrogênio amoniacal que a testemunha sem planta. Os bambus do gênero Guadua foram mais eficientes na remoção de DBO, DQO, coliformes termotolerantes e sólidos voláteis que o tratamento com D. giganteus.
Observou-se que as taxas de aplicação não tiveram influência significativa nas eficiências do
tratamento. Também se avaliaram as espécies de bambu em condições de campo, submetidas
à aplicação de uma lâmina diária de 353,7 mm de efluente por um período de um ano.
Coletaram-se amostras da água do lençol freático com a finalidade de verificar a ocorrência
de contaminação decorrente da aplicação do efluente. Não foi observada contaminação do
lençol freático pela aplicação do efluente no solo vegetado com bambu.
|
Page generated in 0.0562 seconds