• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 476
  • 8
  • 5
  • 4
  • 3
  • 3
  • 3
  • 2
  • Tagged with
  • 497
  • 243
  • 128
  • 91
  • 71
  • 65
  • 60
  • 50
  • 50
  • 50
  • 46
  • 46
  • 46
  • 41
  • 38
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
101

Contribuição ao estudo de colunas pulsadas de pratos perfurados: aplicação à remoção de fenol de soluções aquosas. / Contribution to the study of pulsed sieve plate columns: application to the removal of pehnol from aqueous solutions.

Palma, Mauri Sérgio Alves 01 August 1991 (has links)
Para o estudo usou-se uma coluna de vidro, com 2,75 m de altura e 3,7 cm de diâmetro interno, contendo 29 pratos perfurados (diâmetro dos furos, 0,3 cm e área livre de 35 %), com espaçamento de 9,35 cm. O solvente percorria a coluna no sentido ascendente e a fase contínua, no contrário. A pulsação era fornecida ao sistema líquido por uma biela ligada excentricamente a uma polia, de um lado, e a uma junta de expansão, do outro. A frequência variou de 0 a 2,8 s-1 e a amplitude, de 0,6 a 2,3 cm. Uma primeira série de ensaios foi feita com o sistema binário acetato de n-butila-água, pois, para ele, há dados disponíveis para comparação. Dos resultados obtidos, concluiu-se ser conveniente o desempenho do equipamento. Em seguida, usou-se (a) o sistema metil isobutil cetona-água para levantar curvas de inundação e retenção da fase dispersa para várias condições de operação e (b) o sistema metil isobutil cetona-fenol-água para obter dados de transporte de massa, ou seja, altura equivalente a um estágio de equilíbrio e eficiência da remoção do fenol. Os resultados foram comparados, quando possível, com outros da literatura e com correlações existentes; em alguns casos, obtiveram-se correlações próprias. Os resultados alcançados são reprodutíveis e, para propriedades físicas e geométricas semelhantes, comportam-se de modo compatível com os da literatura. O processo é razoavelmente eficiente na remoção do fenol. / The extraction of phenol from aqueous solutions using a pulsed perforated-plate column was studied. The glass column, 2.75 m high and 3.7 cm internal diameter contains 29 perforated plates (0.3 cm holes and 35% of free area). The solvent flows upwards and the continuous phase, downwards. The pulsation was obtained by the expansion and compression of an expansion joint. Frequency varied from 0 to 2.8 s-1 and amplitude, from 0.6 to 2.3 cm. The initial tests were undertaken with the binary system n-butyl acetate-water because, for this system, there are data for comparison. It was shown that the equipment leads to convenient results. Then, the system methylisobutylketone-water was used to obtain flooding curves and dispersed phase hold-up and the system MIBK-phenol-water to study height equivalent to a theoretical stage and the phenol separation efficiency. The results were compared, whenever possible, with data from the literature and with existing correlations; specific correlations were obtained in certain cases. Results are reproducible and, for similar geometries and physical properties they are compatible with those of literature. The equipment is rather efficient in removing the phenol from the solution.
102

Avaliação da efetividade de diferentes protocolos de irrigação na limpeza do canal radicular / Evaluation of the effectiveness of different irrigation protocols in the root canal cleaning

Fernandes, Samuel Lucas 15 June 2015 (has links)
O objetivo desse estudo foi avaliar a capacidade de dissolução e remoção de biofilme formado in situ, na remoção de smear layer e debris empregando dez protocolos de irrigação final (solução fisiológica com ou sem agitação ultrassônica; ou hipoclorito de sódio como irrigante primário, seguido de solução salina, ou EDTA 17%, ou ácido peracético (PAA) 2%, ou Qmix, com ou sem agitação ultrassônica de ambas as soluções). Duzentos e trinta raízes bovinas foram seccionadas e cortadas com 15mm de comprimento e instrumentadas com o instrumento Reciproc R50. Para a análise da remoção de debris e smear layer foram separadas 100 raízes, que foram clivadas e, no terço apical de uma das metades radiculares, foi confeccionado um sulco longitudinal, simulando extensões de canais ovais, posteriormente preenchidos com detritos artificiais. Após esse procedimento na outra metade foi realizada a formação de smear layer com uma vigora instrumentação da parede com movimentos de limagem. Essas amostras foram levadas ao MEV para análise prévia. Essas metades, depois de justapostas, voltaram a mufla e foram realizados os protocolos de tratamento. A análise dos dados foi realizada por meio de scores. Para a análise da dissolução e viabilidade do biofilme in situ 130 raízes foram separadas preparadas com instrumento R25 e um disco de dentina foi retirado do terço médio com uma trefina. Esses discos foram inseridos em uma placa de hawley, que foi utilizada pelo pesquisador durante três dias. Os discos foram removidos e deixados por 48 horas em BHI, em estufa a 37oC. Após a contaminação os discos voltaram para a raiz de onde foram removidos e fixados com cera utilidade voltando a mufla, sendo tratados e avaliados. Setenta discos foram utilizados para análise da dissolução e viabilidade em confocal e as imagens obtidas foram avaliadas pelo software Bioimage. Sessenta discos foram utilizados para a análise da dissolução do biofilme em MEV, sendo avaliados pré e pós-tratamento. Na comparação entre os grupos para a remoção de smear layer foram encontradas diferenças estatisticamente significantes (P < 0.05) entre os protocolos que utilizavam EDTA e Qmix, com os protocolos utilizando somente solução salina e hipoclorito seguido de solução salina independente da agitação ultrassônica. Enquanto que para a ranhura houve uma diferença estatisticamente significativa entre os grupos que utilizaram PUI e os demais grupos. Tanto a agitação ultrassônica, quanto o uso do hipoclorito de sódio como irrigante primário influenciaram significativamente para a redução do biovolume e da viabilidade bacteriana. O grupo que utilizou o NaOCl, seguido do Qmix associados ao PUI apresentou os menores valores de viabilidade e a maior dissolução do biofilme. O QMix PUI e o PAA/PUI mostraram os melhores resultados de dissolução na análise em MEV.se diferenciando estatisticamente (P<0.05) dos demais grupos. Levando-se em conta todos os critérios analisados, o protocolo que se mostrou mais eficiente foi o NaOCl seguido do QMix e associados a PUI. / The aim of this study was to evaluate the dissolution capacity and removal of biofilm formed in situ, in smear layer and debris removal and debris use ten final irrigation protocols (saline with or without ultrasonic agitation, or sodium hypochlorite as primary irrigating, and then used saline or 17% EDTA, or 2% peracetic acid (PAA), or Qmix, with or without ultrasonic agitation of both solutions). Two hundred and thirty bovine roots were sectioned and cut with 15mm in length and instrumented with Reciproc R50. For the analysis of removal of debris and smear layer were separated 100 roots, which were cleaved, and the apical third of the half of root, has a longitudinal groove made simulating extensions of oval canals, artificial subsequently filled with debris. After this procedure was performed on half the formation of smear layer with a force wall with instrumentation filing motions. These samples were taken to SEM prior to analysis. These halves, after juxtaposed, and again the flask were held treatment protocols. Data analysis was performed by means of scores. For the analysis of the dissolution and viability of the biofilm in situ roots 130 were prepared with R25 separate instrument and dentin disc was taken from the middle third with a trephine. These disks were inserted into a hawley plate, which was used by the researcher for three days. The discs were removed and left for 48 hours in BHI at 37oC. After contamination disks back to the root from which they were removed and fixed with wax utility returning to muffle being treated and evaluated. Seventy disks were used for analysis of dissolution and viability and confocal images were evaluated by Bioimage software. Sixty discs were used for the analysis of the dissolution of the biofilm SEM and are assessed before and after treatment. Comparing the groups for the removal of smear layer statistically significant differences were found (P <0.05) between the protocols used EDTA and Qmix with the protocols using only saline solution and hypochlorite followed by saline independent of ultrasonic agitation. While for the slot there was a statistically significant difference between the groups using PUI and the other groups. Both ultrasonic agitation, and the use of sodium hypochlorite as primary irrigant influenced significantly to the reduction of bacterial viability and biovolume. The group using the NaOCl, and then used Qmix associated with PUI had the lowest viability values and the highest dissolution of the biofilm. The QMix PUI and the PAA / PUI showed the best dissolution results in the analysis MEV.se differentiating statistically (P <0.05) from the other groups. Taking into account all the criteria analyzed, the protocol that was more efficient was the NaOCl and then used QMix and associated with PUI.
103

Perturbações lineares de buracos negros: estabilidade, modos quase-normais e caudas / Linear pertubations of black roles: stability, quasi-normal modes and tails

Zhydenko, Olexandr 12 May 2009 (has links)
Buracos negros têm as suas oscilações próprias, que são chamadas modos quase-normais. As oscilações próprias de buracos negros astrofísicos podem ser observadas no futuro mais próximo com a ajuda de detectores de ondas gravitacionais. Os modos quase-normais são também muito importantes no contexto de teste da estabilidade de objetos negros, da correspondência anti-deSitter/ Teoria Campos Conformes (AdS/CFT) e nas teorias em dimensões mais altas, como os cenários de mundo-brana e teoria das cordas. Esta tese revê um numero de trabalhos, que fornecem um estudo completo do espectro quase normal de grande classe de buracos negros em quatro e mais altas dimensões para campos de vários spins e perturbações gravitacionais. Foi estudada numericamente a dependência dos modos quase-normais sobre um numero de fatores, como a presença da constante cosmológica, o parâmetro de Gauss-Bonnet ou o a éter no espaco-tempo, a dependência do espectro sobre os parâmetros do buraco negro e os campos em consideração. Pela analise do espectro quase-normal, foi estudada a estabilidade de buracos negros Reissner-Nordstrom-de Sitter em dimensões mais altas, buracos negros de Kaluza-Klein com horizontes esmagados, buracos negros de Gauss-Bonnet e cordas negras. Uma atenção especial foi prestada à evolução de campos massivos no contexto de vários buracos negros. Foram considerados os seus toques quase-normais e as caudas de tempo tardio. Alem disso, foram apresentadas duas novas técnicas numéricas: uma generalização da melhora de Nollert para do método de Frobenius para problemas em dimensões mais altas e um método qualitativamente novo, que permite calcular freqüências quase-normais de buracos negros, cujas métricas não são conhecidas analiticamente. Também foi considerada uma possibilidade da construção do análogo acústico do buraco negro de Schwarzschild. / Black holes have their proper oscillations, which are called the quasi-normal modes. The proper oscillations of astrophysical black holes can be observed in the nearest future with the help of gravitational wave detectors. Quasi-normal modes are also very important in the context of testing of the stability of black objects, the anti-de Sitter/ Conformal Field Theory (AdS/CFT) correspondence and in higher dimensional theories, such as the brane-world scenarios and string theory. This dissertation reviews a number of works, which provide a thorough study of the quasi-normal spectrum of a wide class of black holes in four and higher dimensions for fields of various spin and gravitational perturbations. We have studied numerically the dependance of the quasi-normal modes on a number of factors, such as the presence of the cosmological constant, the Gauss-Bonnet parameter or the aether in the space-time, the dependance of the spectrum on parameters of the black hole and fields under consideration. By the analysis of the quasi-normal spectrum, we have studied the stability of higher dimensional Reissner-Nordstr¨om-de Sitter black holes, Kaluza-Klein black holes with squashed horizons, Gauss-Bonnet black holes and black strings. Special attention is paid to the evolution of massive fields in the background of various black holes. We have considered their quasi-normal ringing and the late-time tails. In addition, we present two new numerical techniques: a generalisation of the Nollert improvement of the Frobenius method for higher dimensional problems and a qualitatively new method, which allows to calculate quasi-normal frequencies for black holes, which metrics are not known analytically. Also we considered a possibility of construction of the acoustic analogue of the Schwarzschild black hole.
104

Contribuições ao estudo da não-idealidade de soluções proteicas. / Contributions to the study of non-ideality of protein solutions.

Alves, Kelly Cristina Nascimento 26 March 2013 (has links)
O estudo de soluções proteicas visando à modelagem e à simulação de processos de recuperação e purificação de bioprodutos passa necessariamente pelo estudo da não idealidade, em sentido termodinâmico, destas soluções. Para sistemas em que a concentração de proteína seja baixa, situação comumente presente nestes processos, a principal maneira de avaliar experimentalmente a não idealidade é por meio da determinação da pressão osmótica gerada pela proteína. Deste modo, os objetivos deste trabalho foram: estudar a influência de co-solventes na pressão osmótica de soluções proteicas, verificar a integridade das estruturas secundária e terciária das proteínas nessas soluções, e modelar termodinamicamente os dados de pressão osmótica obtidos. A pressão osmótica foi determinada diretamente por osmometria de membrana, usando soluções de referência com mesma concentração de co-solvente e pH, mas isentas de proteínas. Obtiveram-se dados de pressão osmótica, em função da concentração proteica, de cinco diferentes proteínas (albumina de soro bovino, imunoglobulina G humana, ovalbumina, -lactoglobulina e lisozima) em soluções contendo co-solventes como o polietileno glicol (de diversos tamanhos de cadeia) e sais (sulfato de amônio, sulfato de sódio e cloreto de sódio). Cada conjunto de dados foi obtido em pH e concentração de co-solvente constantes. Observou-se que a presença de co-solventes altera a pressão osmótica, mas este efeito é dependente da proteína, do co-solvente e sua concentração, e do pH da solução. Medidas de fluorescência e de dicroísmo circular das mesmas proteínas permitiram confirmar que elas mantêm sua integridade estrutural nesses meios, o que justifica o uso de equações volumétricas de estado com parâmetros constantes. Os dados de pressão osmótica em função da concentração proteica foram correlacionados por meio de uma equação volumétrica de estado, que combina um termo de esferas rígidas adesivas e um termo de perturbação de ordem zero (aproximação aleatória). O modelo proposto, embora simples, foi suficiente para correlacionar adequadamente o comportamento experimental. / The study of protein solutions aiming at the modeling and simulation of downstream processes entails the study of non-ideality (in thermodynamic sense) of these solutions. For systems wherein the protein concentration is low a situation often encountered in these processes the most important technique to experimentally evaluate this non-ideality is the determination of the osmotic pressure generated by the protein in solution. Thus, the objectives of this work were: to study the influence of co-solvents on the osmotic pressure of protein solutions, to verify the absence of change in the secondary and tertiary structure of proteins in these solutions, and to thermodynamically model the obtained osmotic pressure data. The osmotic pressure was directly measured through membrane osmometry, using protein-free reference solutions with the same pH and co-solvent concentration. The data of osmotic pressure were obtained as a function of protein concentration for five different proteins (bovine serum albumin, human immunoglobulin G, ovalbumin, - lactoglobulin and lysozyme) in solution with co-solvents such as polyethylene glycol (of various chain sizes) and salts (ammonium sulfate, sodium sulfate and sodium chloride). Each data set was obtained at constant pH and co-solvent concentration. It was observed that the presence of co-solvents do shift the osmotic pressure, but this effect is dependent on the protein, the co-solvent and its concentration, and the solution pH. Measurements of fluorescence and circular dichroism of these proteins confirmed that they maintain their structure unchanged in the media, which corroborates the use of volumetric equations of state with constant parameters. The osmotic pressure data as a function of protein concentration were correlated using a osmotic equation of state comprising a repulsive term of adhesive hard spheres and a zero-order perturbation term (random approximation). The proposed model, though simple, was sufficient to properly correlate the experimental behavior.
105

Resolubilidade global para campos vetoriais no toro n-dimensional / Global solvability for vector fields on the n-torus

Gonzalez, Rafael Borro 02 March 2015 (has links)
Abordaremos o estudo de condições para que certas equações diferenciais parciais tenham solução. Consideraremos equações do tipo Lu = f; onde tomamos L em algumas classes de campos vetoriais em toros de dimensão maior que dois. Tais campos vetoriais são operadores que agem no espaço das funções definidas no toro e que são infinitamente diferenciáveis. A principal questão é determinar quando tais operadores têm imagem fechada. Temos também interesse em saber quando que a imagem de tais operadores e um subespaço de codimensão finita, bem como estudar a regularidade de tais operadores. As respostas de tais questões envolvem certas propriedades dos coeficientes desses operadores, onde citamos: a conexidade de sub-níveis de primitivas da parte imaginária dos coeficientes; condições Diofantinas; a ordem de anulamento dos coeficientes e relações entre as ordens de anulamento das partes real e imaginária dos coeficientes; além disso, o número de vezes que a parte imaginária de um coeficiente c muda de sinal entre dois zeros consecutivos de c também desempenha um papel. Conseguimos caracterizar a resolubilidade e a hipoelíticidade global de campos vetoriais do tipo tubo em toros de dimensão maior do que dois, estendendo os resultados em dimensão dois. Depois, em dimensões, fornecemos condições que respondem sobre a imagem ser ou não fechada, para uma outra classe de campos vetoriais que não são do tipo tubo. Uma de tais condições esta relacionada com a famosa condição (P) de Nirenberg-Treves. Em particular, obtemos o mesmo para uma classe de campos vetoriais em dimensão são dois, para os quais a codimensão da imagem foi exaustivamente estudada. / We are concerned with the study of properties so that we can solve certain partial differential equations. We will consider equations of the form Lu = f; where we take L in some classes of vector fields on tori of dimension greater than two. This vector fields are viewed as operators acting on the space of smooth functions deffned on the torus. The main questions to study the closedness of the range of L. It is also of interest to know whe ther the range has finite codimension, as well as to study the regularity of L. The answers of these questions are connected with certain properties of the coeffcients of L; such as: Diophantine conditions; the connectedness of some sublevel sets involving primitive so fthe imaginary part of the coeffcients; the order of vanishing of each coeffcient and relations between the order of vanishing of the real and imaginary parts of each coeffcient; in addition, the number of times that the imaginary part of a coeffcient c changes sign between two consecutive zeros of c also plays a role. We characterize both global solvability and hypoellipticity for vector fields of tube type on tori of dimension greater than two, extending the results in dimension two. More over, in dimension three, we find conditions for the closedness of the range for a class of vector fields which are not of tube type. One of theese conditions is related to the well known Nirenberg-Treves condition (P). In particular,we obtain the same for a class of vector fields on the two- torus,for which the codimension of the range was largely studied.
106

Soluções Parenterais de Grande Volume: avaliação da estabilidade da solução e qualidade física e química da embalagem primária / Large Volume Parenteral Solutions: evaluation of the stability of the solution and physical and chemical quality of the primary packing

Bassi, Ana Claudia Zampronio 04 May 2012 (has links)
As Soluções Parenterais de Grande Volume (SPGV´s) são definidas como solução estéril e apirogênica destinada à aplicação parenteral em dose única, na qual o plástico é o material de acondicionamento primário utilizado. O presente trabalho teve como objetivo avaliar as características físico-químicas e microbiológicas da solução fisiológica de cloreto de sódio 0,9% (m/v), bem como as propriedades químicas e físicas da embalagem primária. Foram utilizadas amostras de solução injetável de cloreto de sódio 0,9% m/v de 500 mL em diferentes apresentações comerciais e tipo de embalagem primária (Grupos A, B, C e D), após armazenamento em câmara climática. Foi realizada avaliação físico-química e microbiológica da solução contida nas diferentes embalagens, antes e após armazenamento de 90 e 180 dias em câmara climática, mantida a temperatura de 40ºC e umidade relativa de 25% conforme estabelecido pela International Conference on Harmonisation (ICH) e 75%, conforme preconizado pela Agência Nacional de Vigilância Sanitária (ANVISA). Realizou-se a determinação dos ensaios químicos e físicos para a embalagem primária em contato com a solução. Além disso, foram avaliados os cuidados de conservação das SPGV´s em instituições hospitalares. Verificou-se a influência da umidade relativa (UR) nas taxas de permeabilidade ao vapor de água, as quais foram estatisticamente significantes (p<0,05) para todos os Grupos. Em todas as comparações, a perda de peso realizada a 25% de UR foi sempre maior que a 75% UR, sendo o Grupo B o que apresentou menor perda de peso comparado aos demais grupos. Foram encontrados volumes abaixo do especificado pela Farmacopéia Americana para o Grupo D em todos os tempos de armazenamento. Falhas de integridade e ruptura das embalagens primárias foram observadas nos Grupos C e D, o que propiciam vazamento da solução e permite a entrada de microorganismos. As propriedades de tração foram avaliadas e o Grupo A apresentou maior valor de ruptura e menor valor de alongamento, quando comparados aos Grupos C e D. Estes apresentaram diferença significativa entre si com relação à resistência máxima à tração, sendo o Grupo C o que apresentou maiores valores deste parâmetro. Os resultados mostram a influência e particularidade de cada tipo de embalagem para acondicionamento primário, além da importância da adequação do ambiente de estocagem do medicamento após a fabricação para que não ocorra o comprometimento da estabilidade e utilização das soluções parenterais. / The Large Volume Parenteral Solutions (LVP´s) are defined as an apyrogenic and sterile solution used in a single dosage in parenteral application, in which the plastic is the primary packaging material used. This study aimed to evaluate physicalchemical and microbiological characteristics of physiological sodium chloride solution 0,0% m/v, as well as the chemical and physical properties of the primary packaging material. In this work, samples of sodium chloride solution injection of 0,9% m/v of 500 mL in many different commercial primary packing (Groups A, B, C and D) were used, after being stored in a climatic chamber. An evaluation of the physical-chemical and microbiological characteristics of the solution was performed by storing the different packages in a climatic chamber during the period of 0, 90 and 180 days, under conditions of 40ºC of temperature and 75% of humidity, as established by the International Conference on Harmonisation (ICH) and 25% RH, according to the specific legislation of the Health Surveillance Agency (ANVISA). An assessment was carried out to determine the chemical and physical tests for the primary packaging in contact with the solution. In addition, was evaluated the conservation of care in hospitals LVP\'s. The results confirmed the influence of relative humidity (RH) in the rate of permeability to water vapor, which was statistically significant (p<0,05) for all groups. In all comparisons, the weight loss performed at 25% RH was always higher than 75% RH, and Group B showed the lowest weight loss compared to other groups. Group D presented results for volume that are different from the specification of United States Pharmacopoeia, at all storage times. Integrity failures and rupture of the primary packages were observed in Groups C and D, which provide leakage of the solution and allows entry of microorganisms. The tensile properties were evaluated and Group A showed higher breakdown and lower elongation as compared to Groups C and D. These Groups presented significant difference between them related to maximum tensile strength and Group C showed the highest values of this parameter. The evaluation results show the influence and particularity of each packing type and also showed the importance of an adequate product storage environment after manufacturing so the use and stability of the parenteral solutions is not jeopardized.
107

Preservação pulmonar com ECMO-tópico ou isquemia fria: avaliação funcional ex vivo e histológica de pulmões não aceitos para transplante pulmonar / Preservation: topical-ECMO or cold ischemia. Functional ex vivo and histological evaluation of donated lungs refused for lung transplantation

Mariani, Alessandro Wasum 10 August 2012 (has links)
Introdução: Apesar dos importantes avanços na preservação pulmonar alcançados nas últimas décadas esta questão permanece longe do ideal e representa um dos maiores problemas enfrentados pelos grupos de transplante pulmonar. O grupo da Suécia liderado pelo Prof. Stig Steen descreveu um novo método de preservação pulmonar chamado de ECMOtópico que foi publicado nos mesmos artigos que divulgaram o sistema de perfusão ex vivo. Todavia, este novo método nunca foi avaliado de forma comparativa contra a forma atualmente mais aceita de preservação pulmonar: a isquemia fria após infusão de solução de preservação. O presente estudo compara estas duas formas de preservação utilizando um modelo de avaliação pulmonar ex vivo. Como objetivos secundários foram estudados: a capacidade de recuperação da função pulmonar pelo sistema ex vivo e a utilidade do modelo experimental bloco pulmonar dividido. Métodos: Quatorze pulmões foram captados de sete doadores em morte encefálica negados para transplante pulmonar. Após a preservação inicial com perfusão anterógrada de solução de LPD-glicose o bloco pulmonar foi dividido, sendo cada lado submetido a um médoto diferente de preservação: ECMO-tópico ou isquemia fria por oito horas. Após este período os pulmões foram re-conectados e avaliados em um sistema de reperfusão pulmonar ex vivo estudando-se parâmetros funcionais e histológicos; biópsias pulmonares foram coletadas em três tempos em cada lado. As variáveis funcionais estudadas foram: capacidade de oxigenação (CO), pressão de artéria pulmonar (PAP) e resistência vascular pulmonar (RVP). As variáveis histológicas foram: escore de lesão pulmonar (ELP), contagem de células apoptóticas (CCA) e estudo de microscopia eletrônica de transmissão. Resultados: Sete casos foram incluídos. A idade média foi de 53.86 anos (±16.7); sexo masculino em 4 casos (57.1%); causa da morte encefálica: acidente vascular encefálico hemorrágico em 5 doadores e trauma crânio encefálico em 2. O lado submetido ao ECMO-tópico: direito em 4 e esquerdo em 3 casos. A média da CO foi 468.00 mmHg (±81.69) no grupo ECMOtópico e 455.86 (±54.05) no grupo isquemia fria (p=0. 758); a mediana da PAP foi de 140 mmHg(120 160) para o ECMO-tópico e 140mmHg(140 150) para isquemia fria (p=0,285); a mediana da RVP 459 dina.s.cm-5 (432,43 492,30) no grupo ECMO-tópico e 474,5 dina.s.cm-5 (459,01 545,45) no grupo isquemia fria (p=0,285). As médias dos escores de lesão pulmonar encontrados foram: para o grupo ECMO-tópico em T1 6,285 (±4,029), em T2 8,714 (±7,714) e em T3 9,571 (±7,857); já no grupo isquemia fria as médias foram em T1 7,571 (±4,429), em T2 7,714 (±4,785) e em T3 7,857 (±6,121) p = 0,531. As médias das contagens de células apoptóticas foram: para o grupo ECMO-tópico em T1 16,71(±2,545), em T2 20,71 (±5,843) e em T3 25,00 (±9,34); no grupo isquemia fria em T1 18,57 (±5,118), em T2 17,57 (±3,014) e em T3 24,86 (±10,374) p=0,803. O estudo de microscopia eletrônica de transmissão não demonstrou diferenças entre os grupos. Conclusões: Neste estudo o ECMOtópico não demonstrou melhora na preservação pulmonar, comparado a isquemia fria, em nenhum dos parâmetros estudados . O modelo de reperfusão pulmonar ex vivo permitiu importante melhora na função pulmonar, e o modelo experimental com bloco pulmonar dividido demonstrou ser um método adequado para estudos experimentais comparativos com pulmões humanos / Background: Besides the important advances in lung preservation reached in last decades this subject continues far from ideal and still represent a major challenge for the lung transplant groups. The Swedish group lead by Prof. Stig Steen has described a new method of preservation so called topical- ECMO along with the ex vivo perfusion system. However this new method has never been tested against the most popular formula of preservation: cold ischemia after single flush perfusion. This study compares these two forms of lung preservation on an ex vivo evaluation model. As secondarys end-points we also study the ex vivo lung perfusion capacity for recover damaged lungs to transplant and the usefulness of the lung bloc split model for experimental study of human lungs. Methods: Fourteen lungs were retrieved from seven brain-dead organ donors refused for transplantation. After initial preservation with single flush of LPD glucose, the lung bloc was divided and each side was preserved by topical-ECMO or cold ischemia for 8 hours. After this the bloc was reconnected than assessed on ex vivo lung system for functional and histological parameters; lung biopsies were collect in three different times on each side. The functional variables assessed were: oxygenation capacity (OC), pulmonary artery pressure (PAP) and pulmonary vascular resistance (PVR). The histological variables were: lung injury score (LIS), apoptotic cells counting and transmission electron microscopy study. Results: Seven cases were included. Mean age 53.86 years (±16.7); male 4 (57.1%); cause of death: hemorrhagic stroke for 5 donors and head trauma for 2. Side of topical- ECMO: Right 4 e Left 3. The mean OC was 468.00 mmHg (±81.69) on topical-ECMO group and 455.86 (±54.05) on Cold Ischemia group (p=0. 758); median PAP median was 140 mmHg(120 160) for topical-ECMO and 140mmHg (140 150) for Cold Ischemia (p=0,285); median PVR 459 dina.s.cm-5 (432,43 492,30) on topical-ECMO group and 474,5 dina.s.cm-5 (459,01 545,45) on Cold Ischemia group (p=0,285). The median for LIS was: topical-ECMO group on T1 6,285 (±4,029), on T2 8,714 (±7,714) and on T3 9,571 (±7,857); Cold Ischemia group on T1 7,571 (±4,429) on T2 7,714 (±4,785) and on T3 7,857 (±6,121) p=0,531. For apoptotic cell counting: topical-ECMO group on T1 16,71(±2,545), on T2 20,71 (±5,843) and on T3 25,00 (±9,34); for Cold Ischemia group it was on T1 18,57 (±5,118), on T2 17,57 (±3,014) and on T3 24,86 (±10,374) p=0,803. The transmission electron microscopy study shows no difference between groups. Conclusions: In our study the topical-ECMO failed to show improvement of lung preservation compared with the cold ischemia in all studied parameters. However the ex vivo lung perfusion model was responsible for a important increase on lung function, and the lung bloc split model appears as a reliable method for experimental human lung studies
108

Estudo do efeito da quitosana utilizada no preparo biomecânico sobre as paredes dos canais radiculares mediante avaliação por espectroscopia e microscopia confocal a laser / The effects of chitosan on root canal walls in the diferente stages of the biomechanical preparation: a spectroscopy and laser confocal microscopy study

Araujo, Vanessa Lessa Cavalcanti de 10 May 2017 (has links)
O objetivo deste estudo foi avaliar, in vitro, o efeito das soluções irrigadoras quitosana a 0,2%; hipoclorito de sódio a 1% e EDTA a 17% na superfície dentinária e na interface de união da dentina/material obturador resinoso. Sessenta fragmentos de dentina, obtidos de 10 caninos superiores humanos, com 4 mm2 de área foram distribuídos em quatro grupos (n=15) de acordo com o tratamento: G1 NaOCl + EDTA + NaOCl, G2 NaOCl + Quitosana + NaOCl, G3 Quitosana + Quitosana + Quitosana, G4 Quitosana + EDTA + Quitosana. As amostras foram imersas por 6 minutos na primeira solução irrigadora (Tempo 1), 3 minutos na segunda (Tempo 2) e 1 minuto na terceira (Tempo 3), simulando o tratamento endodôntico. Foi analisada a composição orgânica e inorgânica das amostras por meio da Espectroscopia Infravermelha por Transformada de Fourier (FTIR) após cada etapa de irrigação. Para segunda fase, 24 caninos superiores humanos, divididos em 4 grupos (n=6), tiveram suas coroas cortadas e as raízes instrumentadas mecanicamente com instrumentos K3 até o instrumento 60.04, irrigadaos com NaOCl a 1% e Quitosana a 0,2% durante o preparo e EDTA a 17% e Quitosana a 0,2% como irrigação final. As amostras foram cortados longitudinalmente para análise do número e do perímetro dos túbulos expostos nos diferentes tempos e a rugosidade da superfície antes (baseline) e após cada fase do tratamento, além da penetração do cimento endodôntico, e avaliação da interface material obturador/dentina, após a obturação (Tempo 3), por meio de microscopia confocal a laser. Os dados foram analisados pela ANOVA e pós-teste de Tukey (p<0,05). Por meio do FTIR, constatou-se que o G4 apresentou maiores valores de matéria orgânica quando comparado aos outros grupos (p<0,05), e foram observados maiores valores para o T3 quando comparado ao T0. Quanto aos valores de matéria inorgânica, o G1 apresentou valores superiores (p<0,05) aos G2 e G3. Não houve diferença quando comparado os tempos para o conteúdo inorgânico (p>0,05). O terço apical apresentou maior valores de conteúdo inorgânico quando comparado aos demais (p<0,05). Por meio do confocal, observou-se que apenas o G3 apresentou maiores valores de perímetro dos túbulos com diferença em relação ao G1,(p<0,05), que o T2 apresentou valores semelhantes ao T1 (p>0,05), e não houve diferença entre os terços radiculares. Na análise da contagem dos túbulos dentinários, observa-se que o G4 apresentou maiores valores, semelhantes ao G3 (p>0,05). O T2 apresentou os maiores valores e o T0 os menores (p<0,05), e o terço cervical apresentou maiores valores em relação aos demais (p<0,05). Na análise da rugosidade, não houve diferença entre os grupos, e nem entre os terços radiculares (p>0,05), sendo que o T0 apresentou maiores valores, com diferença em relação ao T1 e T2 (p<0,05). Na análise da interface material obturador/dentina, não houve diferença entre os grupos, e o terço apical apresentou menor extensão de tags formados (p<0,05). A Quitosana como solução irrigadora produziu efeitos favoráveis na dentina radicular sem afetar a interação do substrato com o cimento endodôntico. / The aim of this study was to evaluate, in vitro, the influence of irrigation solutions, used during instrumentation of root canals - chitosan at 0.2%; 1% sodium hypochlorite and 17% EDTA - on dentin, by means of Fourier Transform Infrared Spectroscopy (FTIR) and laser confocal microscopy. Sixty dentin fragments, obtained from 10 human canines, with 4 mm2 area were distributed in four groups (n = 15) according to the treatment: G1 NaOCl + EDTA + NaOCl, G2 NaOCl + Chitosan + NaOCl, G3 Chitosan + Chitosan + Chitosan, G4 Chitosan + EDTA + Chitosan. The samples were immersed for 6 minutes in the first irrigation solution (Time 1), 3 minutes in the second (Time 2) and 1 minute in the third (Time 3), simulating the endodontic treatment. The organic and inorganic composition of the samples were analyzed by Fourier Transform Infrared Spectroscopy (FTIR) after each irrigation step. In a second phase, 24 teeth were divided into 4 groups (n = 6), cut longitudinally to analyze the number and perimeter of the exposed tubules at different times, the surface roughness before and after each treatment phase. The penetration of the endodontic sealer, and evaluation of the dentin interface, after the obturation (Time 3), by laser confocal microscopy. Data were analyzed by ANOVA and Tukey post hoc test (p<0.05). Using FTIR, G4 presented higher values of organic content when compared to the others groups (p <0.05), and higher values were observed for T3 when compared to T0. There was no difference when comparing the times for the inorganic content (p> 0.05). The apical third had higher values of inorganic content when compared to the others (p <0.05). With the aid of the confocal analysis, it was observed that only G3 presented higher values of tubule perimeter with difference in relation to the G1, (p <0.05), that T2 presented values similar to T1 (p> 0.05), And there was no difference between the root thirds. In the analysis of the dentinal tubule count, it was observed that G4 presented higher values, similar to G3 (p> 0.05). The T2 presented the highest values and T0 the lowest (p <0.05), and the cervical third had higher values compared with the others (p <0.05). Regarding the analysis of roughness, there was no difference between the groups, nor between the root thirds (p> 0.05), and the T0 presenting higher values compared with T1 and T2 (p <0.05). In the analysis of the dentin interface, there was no difference between the groups, and the apical third had a smaller extension of the formed tags (p <0.05). Chitosan produced less chemical changes in root dentin when compared to the other solutions.
109

Influência de bebidas e escovação nas propriedades físicas de uma resina composta / Influence of beverages and brushing on the physical properties of a composite resin

Lepri, Cesar Penazzo 23 January 2009 (has links)
Objetivo: Este estudo avaliou a influência de bebidas e escovação na estabilidade de cor, rugosidade superficial e microdureza em profundidade de uma resina composta. Materiais e Método: 120 discos (10mm de diâmetro X 2mm de espessura) de resina composta (Filtek- Z250) foram preparados e polidos após 24 horas. A cor inicial e a rugosidade superficial inicial foram mensuradas e os espécimes foram divididos aleatoriamente em quatro grupos (vinho tinto, refrigerante, aguardente, ou saliva artificial controle) e três subgrupos (sem escovação; escovação com Colgate, ou escovação com Close Up Whitening). Os espécimes foram imersos na sua respectiva solução, 5x ao dia, por 5 minutos, durante 30 dias, sendo dois subgrupos escovados ao final de cada dia (120 movimentos/dia). A cor foi mensurada no 15º e no 30º dia de imersão; a rugosidade superficial final foi medida no 30º dia. Após o período de imersão, os espécimes foram armazenados em saliva artificial por 7 dias, quando a superfície dos mesmos foi polida e imediatamente realizou-se uma mensuração de cor. A alteração de cor foi mensurada com um espectrocolorímetro e analisada pelos valores de &Delta;E, &Delta;L, &Delta;a, e &Delta;b. Os valores de rugosidade (Ra-&mu;m) foram medidos com um rugosímetro. Com relação à microdureza, os espécimes primeiramente foram incluídos em resina de poliéster e seccionados no sentido transversal. Após o polimento destas superfícies, foram realizadas mensurações nas profundidades de 30&mu;m, 60&mu;m, 90&mu;m, 120&mu;m e 250&mu;m, empregando os parâmetros 25gf/40s de microdureza Knoop. Os dados foram submetidos à ANOVA e teste de Fisher\'s (&alpha;=5%). Resultados: Os valores de alteração de cor foram estatisticamente diferentes após a imersão nas bebidas; o vinho tinto promoveu a maior alteração, seguido pelo refrigerante e aguardente, que foram similares entre si e diferentes da saliva artificial. Nenhuma diferença foi observada com ou sem escovação, independentemente do dentifrício utilizado. Ao 30º dia, os espécimes apresentaram uma mudança de cor mais intensa do que ao 15º dia, após o repolimento, a cor dos espécimes foi similar à cor do 15º dia. As bebidas e a escovação influenciaram negativamente na rugosidade da superfície. Em relação à microdureza, não houve diferença significativa entre os grupos, independentemente da profundidade analisada. Conclusões: A mudança de cor da resina composta foi influenciada apenas pelas bebidas; a escovação não afetou a propriedade analisada. O repolimento não foi suficiente para promover o retorno da cor dos espécimes aos valores iniciais. A rugosidade superficial foi influenciada negativamente tanto pelas bebidas quanto pela escovação. Para a microdureza, a resina composta apresentou resultados similares independentemente das bebidas utilizadas e da presença ou ausência de escovação nos espécimes avaliados. / Objective: This study evaluated the influence of beverages and brushing on the color change, surface roughness and microhardness in depth of a composite resin. Methods: 120 composite resin disks (10mm-øX2mm-thickness; Filtek-Z250) were prepared and polished after 24h. Initials color and surface roughness were measured and specimens were randomly assigned into four groups (red wine, soft drink, sugar cane spirit, or artificial saliva control) and three subgroups (without brushing; brushing with Colgate, or brushing with Close Up Xtra Whitening). Specimens were immersed in the beverage 5x/day, for 5 minutes, over 30 days, being two subgroups brushed at the end of every day (120 moving/day). Color was measured at the 15th and 30th days of immersion; final surface roughness was measured at the 30th day. After the immersion period, specimens were stored in artificial saliva for 7 days, when their surfaces were repolished and immediately assessed by color. Color change was measured with a spectrocolorimeter and analyzed by &Delta;E, &Delta;L, &Delta;a, and &Delta;b values. The values of roughness (Ra - &mu;m) were measured with a rugosimeter. As regard microhardness, the specimens were firstly included in polyester resin and sectioned in the transverse direction. After polishing these surfaces, measurements were realized at depths of 30&mu;m, 60&mu;m, 90&mu;m, 120&mu;m and 250&mu;m, employing the parameters 25gf/40s of microhardness Knoop. Data were submitted to ANOVA and Fisher\'s tests (&alpha;=5%). Results: Color change values were statistically different after immersion in the beverages; red wine promoted the highest alteration, followed by soft drink and sugar cane spirit, which presented similar results among them and different from saliva. No difference was observed with or without brushing independently of the toothpaste used. At 30th day, specimens exhibited a color change higher than 15th day; after repolishing, the color of the specimens was similar to 15th day. Beverages and brushing negatively influenced the surface roughness. In relation to microhardness, there was no significant difference among groups, regardless of the depth examined. Conclusions: Color change of the composite resin was influenced only by the beverages and brushing did not affect the analyzed property. The repolishing was not sufficient to promote the return of the specimens color to their initial values. The surface roughness was negatively influenced both by the beverage as brushing. For microhardness, the composite resin showed similar results regardless of the beverages used and the presence or absence of brushing in the specimens tested.
110

Avaliação in vitro da microtração de sistemas adesivos à dentina irrigada com soluções endodônticas: Influência da degradação da interface adesiva / In vitro evaluation of systems on microtensile bond strength to orrogated dentin with endodontic solutions. Adhesive interface degradation influence

Galafassi, Daniel 27 January 2009 (has links)
O objetivo desse trabalho foi avaliar a influência da resistência de união de sistemas adesivos à dentina irrigada com substâncias endondônticas, após a degradação da interface adesiva e análise morfológica da interface adesiva por meio de microscopia eletrônica de varredura (MEV). Foram selecionados sessenta terceiros molares, que tiveram a porção oclusal removida e planificada expondo a dentina profunda. Os espécimes foram irrigados com hipoclorito de sódio a 2,5% por 30 minutos e em seguida em EDTA 17% por 5 minutos. Após a irrigação da superfície detinária os dentes foram divididos aleatoriamente em seis grupos (n = 10) de acordo com o sistema adesivo empregado: G1 e G2 - Clearfil (Kuraray); G3 e G4 - Single Bond 2 (3M) e G5 e G6 - XP Bond (Dentsply). Após a aplicação do sistema adesivo, foi confeccionado um platô de resina composta Z100 (3M). A degradação da interface adesiva foi realizada por meio de estocagem em água deionizada/ciclagem térmica: 24 horas de estocagem em água deionizada/nenhum ciclo (grupos G1, G3 e G5) e 6 meses de estocagem em água deionizada/12.000 ciclos (grupos G2, G4 e G6). Após os períodos pré-estabelecidos em cada grupo, os conjuntos dente/resina foram seccionados de forma a se obter 4 palitos de aproximadamente de 1mm2, que foram submetidos ao teste de microtração. A análise morfológica da interface foi realizada por meio de MEV. Os dados obtidos foram submetidos a ANOVA e teste de Tukey ao nível de 5%. Verificou-se que houve diferença significativa entre os adesivos (p<0,01). A durabilidade da adesão da resina composta a dentina irrigada com solução endodôntica não foi afetada após 6 meses de estocagem em água e 12.000 ciclos térmicos (p<0,05). A análise da interface adesiva evidenciou que os sistemas adesivos não alteraram o padrão de união mesmo após 6 meses de ciclagem térmica e degradação em água, exceto para o sistema adesivo XP Bond. Pode-se concluir que a dentina irrigada com NaOCl e EDTA apresentou menor resistência a microtração quando do emprego do sistema adesivo XP Bond. A degradação da interface por meio do armazenamento em água e ciclagem térmica não influenciou na resistência de união, independente do sistema adesivo empregado. / The aim of the present study was to survey the influence of endodontic irrigants on the adhesion resistance of adhesive systems to human dentin, after the degradation of adhesive interface and morphologic analysis of adhesive interface for Scanning Electronic Microscopy SEM. Sixty molar thirds were selected. The deep dentin was exposed removing and ground the oclusal portion. The specimens were irrigated with sodium hypochlorite 2,5% for 30 minutes followed by EDTA 17% for 5 minutes. Subsequently, teeth were divided randomly in six groups (n=10) accordingly to adhesive system applied: G1 and G2 Clearfil (Kuraray); G3 e G4 - Single Bond 2 (3M) e G5 e G6 - XP Bond (Dentsply). After adhesive system application, a composite resin Z100 (3M) was built up created. The degradation of the adhesive interface was realized by storage the specimens in deionized water and thermocycling: 24 hours of deionized water storage/no cycle (groups G1, G3 and G5) and 6 months storage in deionized water/12.000 cycles (groups G2, G4 and G6). After pre-established periods of each group, the systems tooth/resin were sectioned in order to obtain 4 sticks of approximately 1mm2, which were subjected to microtensile bond strength test. The morphologic analysis of interface was performed for SEM. Results were analyzed with ANOVA and Tukey test to level 5%. Significant difference between adhesives was verified (p<0,01). The water storage (6 months) coupled with thermocycling (12.000 cycles) did not affected significantly the resistance to microtensile bond strength of the dentin (p<0,05). The conclusion is that dentin irrigated with NaOCl and EDTA presented less resistance to microtensile bond strength when XP Bond Adhesive system was utilized. The interface degradation through water storage and thermocycling had no effect on the resistance of the dentin bond, independently of the adhesive system applied.

Page generated in 0.0507 seconds