• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 258
  • 82
  • 39
  • 13
  • 9
  • 6
  • 5
  • 5
  • 3
  • 3
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 502
  • 232
  • 102
  • 56
  • 52
  • 51
  • 49
  • 49
  • 47
  • 44
  • 41
  • 41
  • 39
  • 37
  • 35
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
121

Análise químico-farmacêutica de preparações injetáveis de ampicilina sódica /

Tótoli, Eliane Gandolpho. January 2013 (has links)
Orientador: Hérida Regina Nunes Salgado / Banca: Helder Ferreira Teixeira / Banca: Marlus Chorilli / Resumo: A ampicilina sódica é um antimicrobiano β-lactâmico, semi-sintético, de uso parenteral, pertencente ao grupo das penicilinas. Trata-se da primeira penicilina semi-sintética a apresentar atividade contra bacilos Gram-negativos, abrindo o campo de penicilinas de amplo espectro. Existem vários trabalhos na literatura que descrevem métodos analíticos para análise da ampicilina em formas farmacêuticas. A maior parte deles envolve a cromatografia líquida de alta eficiência (CLAE) com fases móveis constituídas por soluções-tampão, as quais podem danificar as colunas cromatográficas, ou métodos que envolvem o gasto de grandes quantidades de solventes orgânicos. No entanto, a tendência é que as indústrias busquem minimizar e/ou eliminar o uso de solventes orgânicos de seus processos com o objetivo de reduzir os impactos de suas atividades sobre o meio ambiente. Desta forma, este trabalho teve como objetivo principal o desenvolvimento de novos métodos analíticos para análise de ampicilina sódica na forma farmacêutica de pó liofilizado para solução injetável, que apresentem menor impacto sobre o meio ambiente e que sejam mais práticos, mais seguros para os operadores e mais econômicos que as metodologias analíticas já descritas para a ampicilina. A ampicilina sódica foi analisada qualitativamente quanto à umidade e solubilidade. Também foi realizada análise por espectrofotometria no infravermelho e desenvolvido método por cromatografia em camada delgada (CCD) indicativo de estabilidade. Quanto à análise quantitativa, foi validado método por CLAE com detecção ultravioleta (UV) a 210 nm, fase móvel composta por etanol e água (40:60, v/v) e faixa de concentração de 70,0 a 120,0 μg/mL, exatidão de 99,54%, teor de 96,83% e tempo de retenção médio de 3,1 minutos; ensaio microbiológico pelo método... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Ampicillin sodium is a semi-synthetic β-lactam antibiotic for parenteral use, belonging to the penicillin group. It was the first semi-synthetic penicillin to show any action against Gram-negative bacilli, opening a field of broad spectrum penicillins. There are several published studies in literature that describe analytical methods for ampicillin in pharmaceutical dosage forms. Most of them are related to high performance liquid chromatography (HPLC) using mobile phases constituted by buffer solutions, which may damage the chromatographic columns over time, or methods that involve, mostly, the use of large amounts of organic solvents. However, the tendency is that industries seek to minimize or eliminate the use of organic solvents in their processes in order to reduce the impacts of their activities on the environment. In this way, this study aimed to develop new analytical methods for the analysis of ampicillin sodium in lyophilized powder for injectable solution, which have the lowest impact on the environment as possible and that be more convenient, safer for operators and more economical than the analytical methodologies already described for ampicillin. Ampicillin sodium was analyzed qualitatively as the moisture content and solubility characteristics. Furthermore, it was performed an analysis by infrared spectroscopy and was developed a stability indicative method by thin layer chromatography (TLC). Regarding the quantitative analysis, it was validated HPLC methodology with UV detection at 210 nm, mobile phase composed by ethanol and water (40:60 v /v), the concentration range from 70.0 to 120.0 μg/mL, accuracy of 99.54%, content of 96.83% and average retention time of 3.1 minutes; microbiological assay by turbidimetric method, in the concentration range from 2.0 to 8.0 μg/mL, using Staphylococcus aureus ATCC 26923, with accuracy... (Complete abstract click electronic access below) / Mestre
122

Avaliação clínica da sensibilidade e efetividade do clareamento em consultório de dentes polpados, com e sem o emprego de fonte de luz: controle de 12 meses / Clinical evaluation of sensitivity and effectiveness of in-office whitening in sounds teeth, with and without the use of light source: 12 months follow-up

Enio Ratton Rosa 14 May 2012 (has links)
Este estudo in vivo analisou comparativamente duas técnicas de clareamento de dentes polpados, quanto ao grau de sensibilidade, mudança de cor e estabilidade do tratamento num período de doze meses. Dez pacientes foram selecionados de acordo com os critérios de inclusão e exclusão, e submetidos ao clareamento em consultório, sendo que o mesmo paciente recebeu os dois protocolos de clareamento. Grupo A (GA): três aplicações de 15 (totalizando 45) do gel de peróxido de hidrogênio (PH) 35% (Lase Peroxide Sensy, DMC Equipamentos Ltda.), nos hemi-arcos inferior e superior esquerdo. Grupo B (GB): três aplicações do gel PH 35% ativado com luz híbrida de LED/laser de diodo (Whitening Lase II DMC Equipamentos Ltda.) por 2, com intervalo de 30 (730), totalizando 2230, nos hemi-arcos inferior e superior direito. A avaliação da cor foi realizada com o espectrofotômetro Vita EasyShade (VITA), sendo a diferença mensurada através do sistema CIE-Lab antes do clareamento, após 24 horas, 1 semana, 6 e 12 meses. A sensibilidade dentária foi avaliada por meio do questionário VAS antes, imediatamente após o clareamento, após 24 horas e 1 semana. Para as variáveis luminosidade (?L) e alteração de cor (?E), ANOVA a dois critérios (período e luz) revelou haver diferenças estatisticamente significantes intra e intergrupos em função dos períodos avaliados (p<0,001). O teste de Tukey (p<0,001) para comparações individuais apontou diferenças significantes intergrupos para os dentes superiores nos períodos de 1 mês, 6 meses e 1 ano com os demais tempos avaliados. Para os dentes inferiores não houve diferenças estatísticas intra e intergrupos (p=0.0821). O GB ativado com luz apresentou, imediatamente após o clareamento, o menor grau de sensibilidade dentária com diferença estatística (p=0,043) em comparação ao GA (sem luz). Os dois protocolos de clareamento com e sem luz avaliados durante 12 meses foram semelhantes quanto a efetividade do clareamento dental. Por outro lado, a utilização da fonte de luz híbrida diminuiu o tempo de tratamento em 50% e proporcionou menor grau de sensibilidade pós-operatória. / This study examined in vivo comparison of two techniques for whitening pulp teeth, the degree of sensitivity, color change and stability of treatment over a period of twelve months. Ten patients were selected according to the criteria for inclusion and exclusion, and subjected to in-office bleaching, and the same patient received both protocols whitening. Group A (GA): three applications of 15\' (total 45\') of hydrogen peroxide gel (PH) 35% (Sensy Lase Peroxide, DMC Equipment Ltd.), Hemi-arches in the lower and upper left. Group B (GB): three applications of the gel 35% PH with light activated hybrid LED / laser diode (Whitening Lase II DMC Equipments Ltda.) By 2 \', with an interval of 30\' (7\'30\"), totaling 22\'30\", hemi-arches in the lower and upper right. The evaluation was performed color with the spectrophotometer Vita Easyshade (VITA), and the difference measured with the CIE-Lab system before the treatment, after 24 hours, 1 week, 6 and 12 months. The tooth sensitivity was assessed using the VAS questionnaire before and immediately after bleaching, after 24 hours and 1 week. For the variable brightness (?L) and color change (?E), two-way ANOVA (time and light) revealed statistically significant differences within and between groups on the basis of the evaluation period (p<0.001). The Tukey test (p<0.001) for individual comparisons showed significant differences between groups for the upper teeth at 1 month, 6 months and 1 year with the other times evaluated. For the lower teeth no statistical differences within and between groups (p=0.0821). The GB had activated with light, immediately after bleaching, the lowest degree of tooth sensitivity with statistical difference (p=0.043) compared to GA (no light). The two protocols with and without light bleaching evaluated during 12 months were similar in effectiveness of tooth whitening. Moreover, the use of the light source hybrid decreases the time of treatment provided by 50% and less sensitivity postoperative.
123

Análise da cicatrização de lesões cutâneas através da espectrofotometria: estudo experimental em ratos diabéticos.

Paulo de Tarso Camillo de Carvalho 06 February 2002 (has links)
O trabalho tem por objetivo desenvolver um protocolo experimental de avaliação da cicatrização de lesões cutâneas em ratos diabéticos (aloxânicos) através da análise do espectro de cor das fibras colágenas e de macrófagos. Considerando que em indivíduos normais, os mecanismos que regulam a cicatrização são bem conhecidos, determinou-se neste estudo verificar os mecanismos que regulam a cicatrização de animais diabéticos. Utilizamos inicialmente 60 ratos Wistar, machos. O diabetes foi induzido por injeção intravenosa (veia dorsal do pênis de Aloxana (2, 4, 5, 6 - Tetraoxypyrimidina; 5 - 6 Dioxyuracila) SIGMA, 0,1ml de solução a cada 100 g. de peso corporal. Para se chegar ao número de 12 ratos diabéticos, foram utilizados 48 ratos, destes 39,58% não desenvolveram a hiperglicemia nos néveis fixados (acima de 250mg/l ), 6,25% morreram por hipoglicemia nas primeiras 24 horas; nas 48 horas seguintes 20,83% % morreram por hiperglicemia, 4,17% morreram durante procedimento anestésico e 4,17% morreram ao longo do experimento. Foi realizada uma lesão no dorso dos animais que foram divididos em 2 grupos com 12 animais cada e receberam a denominação de Grupo 1 Diabético Grupo 2 Não Diabético. As 24 amostras dos tecidos colhidas no 3º, 7º e 14º após a lesão, foram incluídas em parafina e cortadas transversalmente e passaram por dois processos distintos, ou seja, 24 amostras por coloração com Tricrômico de Masson e 24 amostras pela técnica imunohistoquímica - anticorpo monoclonal HAM 56. Utilizou-se o software IMAGELAB para a análise morfométrica do percentual de fibras colágenas por densidade de cor e número de macrófagos evidenciados pela imunohistoquímica. Os dados obtidos em relação ao percentual de fibras colágenas e macrófagos foram tratados estatisticamente por testes paramêtricos de análise de variância, segundo dois critérios, e confirmados pelo Teste "Tukey" onde se fixou em 5% o nível de rejeição da hipótese de nulidade. Fixando-se: para ambos p< 0,5. Concluímos que o protocolo experimental para avaliação da cicatrização de lesões em ratos diabéticos se mostrou eficaz, demonstrando que a cicatrização no grupo de animais diabéticos apresentou-se retardada durante todas as etapas do processo de reparo e que a porcentagem de fibras colágenas e macrófagos pode ser facilmente analisada pelo espectro de cor. / This study aims to develop an experimental evaluation protocol of the healing of skin wounds in diabetic rats (aloxanic) through the analysis of color spectrum of collagenous fibres and macrophage. Considering that the mechanisms regulating scarring in normal individuals are well-known it was determined to verify the mechanisms regulating the scarring in diabetic animals. 60 Wistar male rats were used. Diabetes was induced by means of intravenous injection (dorsal penis vein of Aloxana (2, 4, 5, 6 - Tetraoxypyrimidine; 5 - 6 Dioxyuracila) SIGMA, 0,1 ml of solution per 100g of body weight. In order to reach 12 diabetic rats, 48 rats were used. 39.58% of them did not develop hypoglycemia in the established levels (above 250mg/l), 6.25% died from hypoglycemia within 24 hours; in the following 48 hours, 20.83% died from hypoglicemia, 4,17% died during the anesthetic procedures and 4,17% died along the experiment. In order to follow the study a lesion was performed on the back of the animals which were divided into two groups with 12 animals each and received the following denomination: Group I Diabetic and Group II Non-Diabetic. The 24 tissue samples collected in the 3rd , 7th and 14th days after the lesion were included in paraffine and transversally cut and suffered two different processes, that means, 24 samples received coloration with Masson Tricomic and 24 samples suffered the imunohistochemical technic - HAM 56 monoclonic antibody. The software IMAGELAB was used in the morphometric analysis of the percentage of collagen by density of colour and number of macrophage highlighted by immunehistochemistry The obtained data concerning the percentage of collagenous fibres and the number of macrophage were statistically treated by ANOVA following two criteria and confirmed by Tukey Test where the rejection level of nullity possibility was established to be 5% (alpha<=0,05). It was obtained p< 0,5 for both. We came to the conclusion that the experimental protocol for the evaluation of healing of wounds in diabetic rats has proved efficient, showing that the healing in the group of diabetic animals is slowed down during all the stages of the repairing process; the percentage of collagenous fibres and macrophage can be easily analysed by the colour spectrum.
124

Desenvolvimento de sistemas de DL-Alanina para dosimetria da radiacao gama e de eletrons

COSTA, ZELIA M. da 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:37:49Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:56:14Z (GMT). No. of bitstreams: 1 05378.pdf: 4874406 bytes, checksum: 5202dee2fe2fd96e7538be3969e8b4c4 (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
125

Estudo para a determinacao de Samario, Europio, Terbio, Disprosio e Itrio em matriz de oxido de Gadolinio por espectofotometria de absorcao atomica

CAIRES, ANTONIO C.F. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:32:05Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:57:56Z (GMT). No. of bitstreams: 1 02298.pdf: 1286663 bytes, checksum: ed62610cdfd3bfac1a6ef998fc9615de (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
126

Dosimetria na regiao de 0.25Mrad a 25Mrad utilizando filmes de triacetato de celulose (CTA)

DAFFERNER, J.M. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:50:33Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:58:54Z (GMT). No. of bitstreams: 1 00358.pdf: 1139096 bytes, checksum: c1b62a118be24d3d34fe640cb74bff0b (MD5) / Dissertacao (Mestrado) / IEA/D / Escola Politecnica, Universidade de Sao Paulo - POLI/USP
127

Controle analitico dos agentes redutores na particao uranio/plutonio no processo purex

ARAUJO, IZILDA da C. de 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:38:29Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:05:08Z (GMT). No. of bitstreams: 1 06053.pdf: 1184554 bytes, checksum: aac0037c0916772662fdb86b2a517253 (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
128

Desenvolvimento de uma metodologia para a separação de samário e európio a partir de mistura de óxidos de terras raras por redução eletroquímica/precipitação

CHEPCANOFF, VERA 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:51:58Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:07:37Z (GMT). No. of bitstreams: 0 / A utilização das terras raras (TR) em larga escala teve início com a patente de Welsbach em 1903, que é ainda aplicada na fabricação de pedras de isqueiros. Hoje as TR estão presentes nas mais diferentes áreas, como na produção de superligas, vidros especiais, pigmentos, cerâmicas, imãs permanentes, lasers, eletroeletrônicos, catalisadores, ressonância magnética nuclear, etc., movimentando, na última década, um mercado de US$ 2 bilhões por ano. Devido às suas propriedades muito semelhantes, os elementos das TR são difíceis de serem separados, requerendo, normalmente, processos complexos, o que os torna de elevado preço de comercialização. Elementos como o európio (Eu) e o samário (Sm), cujos teores nos materiais que contém TR são baixos (cerca de 0,05% e 2%, respectivamente, na monazita), são caros e os campos de aplicação destes materiais justificam a busca por outros processos de separação, que sejam no mínimo mais simples e/ou mais eficientes. O estado trivalente é característico para todas as TR, mas alguns elementos podem apresentar outros estados de oxidação, como o Ce, Eu, Sm e Yb. No caso do Eu e do Sm, foco de estudo neste trabalho, o estado divalente é facilmente obtido por redução eletroquímica nos potenciais –0,65V e –1,55V (vs. SCE), respectivamente. Este fato torna possível a separação destes elementos das demais terras raras e entre eles mesmos. Portanto, fazendo uso desta característica, propôs-se um processo de separação individual do Eu e do Sm em meio (NH4)2SO4 por eletro-redução/precipitação, onde o Sm é separado primeiramente como sulfato e o Eu, que permanece em solução, é precipitado após a diminuição da temperatura e do potencial aplicado. O processo desenvolvido a partir de uma solução sintética de Eu e Sm foi aplicado a uma mistura de óxidos de TR semi-pesadas produzida no IPEN-CNEN/SP, obtendo-se a separação do Sm. Este produto foi analisado por espectrofotometria, indicando elevado grau de pureza. / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
129

Determinação espectrofotometrica de acetato de medroxiprogesterona em medicamento pela reação com Mo (VI) em 'H IND. 2' S'O IND. 4' / Spectrophotometric determination of medroxioprogesterone in pharmaceuticals using a reaction with Mo (VI) in 'H IND. 2' S'O IND. 4'

Pinheiro, Tania Aparecida Lopes 21 November 2006 (has links)
Orientador: Adriana Vitorino Rossi / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Quimica / Made available in DSpace on 2018-08-09T10:06:34Z (GMT). No. of bitstreams: 1 Pinheiro_TaniaAparecidaLopes_M.pdf: 1079209 bytes, checksum: 7315b8210dfb843979f6a17ba083ed67 (MD5) Previous issue date: 2006 / Resumo: Acetato de medroxiprogesterona (AMP) é um derivado da progesterona que vem sendo usado para contracepção por cerca de 30 milhões de mulheres e também vem aplicado em tratamentos de câncer. Como em alguns casos, AMP gera efeitos colaterais desfavoráveis, sua dosagem deve ser bem controlada. Neste trabalho, foi desenvolvido um método espectrofotométrico para quantificação de AMP em fármacos pela reação com Mo(VI) em meio fortemente ácido. Testes preliminares como avaliação do ponto de fusão e spot test com ácido sulfúrico foram introduzidos para identificar o AMP de outros compostos, como derivados de cortisona que também podem reagir com Mo(VI). A reação foi otimizada a partir da avaliação de algumas variáveis do sistema reacional: tempo e temperatura de aquecimento, solvente e concentração de ácido. Os resultados obtidos indicaram que as melhores condições para o sistema reacional são: solução 9 mol L de H2SO4, 70 minutos de aquecimento a 90 °C e uso de AMP em acetonitrila. Nestas condições, foram obtidas curvas analíticas com a absorbância em 406 nm do produto formado cuja concentração é diretamente proporcional à concentração de AMP na faixa de 5,87x10 a 10,00x10 mg mL, com coeficiente de correlação linear = 0,9972 e limite de detecção = 1,77x10 mg mL. A precisão foi avaliada por intra (repetibilidade) e inter (precisão intermediária) testes, tendo sido obtidos desvios máximos de + 1,9%. Quando comparado com um método de quantificação de AMP em medicamentos comerciais por cromatografia líquida de alta eficiência, os resultados com o método proposto não apresentaram diferenças estatisticamente significativas com 95 % de confiança, indicando bom desempenho do método baseado na reação colorimétrica, que tem favoráveis características de simplicidade instrumental / Abstract: Acetate of medroxiprogesterona (AMP) is one derivative of the progesterone, that have been used used as contraceptive method for about 30 million women. And in treatments of cancer. In some cases, AMP cause favorable collateral effect, therefore its dosage must be well controlled. In this work, a spectrophotometric method for quantification of AMP in pharmaceutical preparation using the reaction with Mo(VI) in strong acid was developed. Preliminary tests as evaluation of the fusing point and spot test with H2SO4 had been introduced in order to identify the AMP from other compounds, as corticoids, that ca also react with Mo(VI). The reaction was optimized from the evaluation of some reaction variable: time and temperature of heating, AMP solvent, acid concentration. The optimized conditions are 9 mol L H2SO4; heating for 70 minutes at 90 °C and acetonirile solvent for AMP. In these conditions, analytical curves of absorbance at 406 nm of the product formed whose concentration is directly proportional to the initial concentration of AMP were obtained from 5,87x10 a 10,00x10 mg mL , with linear coefficient = 0,9972 and detection limit = 1,77x10 mg mL. The precision was evaluated by intra (repeatability) and inter (intermediate precision) tests, having been achieved maximum relative deviation = + 1,9 %. When compared with a HPLC method of quantification of AMP in commercial medicines, the results achieved with this method did give statistical significant differences at 95 % confidence level, indicating good performance of the colorimetric method, which has the advantage of instrumental simplicity / Mestrado / Quimica Analitica / Mestre em Química
130

Avaliação da eficacia de clareamento e do aumento de temperatura de fraqmentos dentais submetidos a tres sistemas clareadores, catalisados por diferentes fontes de lus / Influence of different light sources on the temperature rise and effectiveness of three bleaching agents

Lima, Débora Alves Nunes Leite, 1978- 14 August 2018 (has links)
Orientador: Jose Roberto Lovadino / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-14T19:37:51Z (GMT). No. of bitstreams: 1 Lima_DeboraAlvesNunesLeite_M.pdf: 1094149 bytes, checksum: 7115932ab994079522229871a69214ce (MD5) Previous issue date: 2005 / Mestrado / Dentística / Mestre em Clínica Odontológica

Page generated in 0.6469 seconds