• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 110
  • 52
  • 15
  • 9
  • 9
  • 8
  • 3
  • 3
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 215
  • 69
  • 30
  • 25
  • 24
  • 21
  • 21
  • 20
  • 20
  • 19
  • 18
  • 18
  • 18
  • 17
  • 16
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
111

Reforço a flexão de vigas de concreto de elevada resistencia por meio da colagem de manta polimerica reforçada com fibras de carbono

Silva, Augusto Ottoni Bueno da 05 February 2001 (has links)
Orientador: Armando Lopes Moreno Junior / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil / Made available in DSpace on 2018-07-28T20:38:13Z (GMT). No. of bitstreams: 1 Silva_AugustoOttoniBuenoda_M.pdf: 16909483 bytes, checksum: 0c47482ffb59cda43bf62e03637ac5a4 (MD5) Previous issue date: 2001 / Resumo: O objetivo deste trabalho é oferecer uma parcela de contribuição ao estudo do comportamento de vigas de concreto de alta resistência reforçadas externamente com mantas unidirecionais de polímero reforçado com fibras de carbono (pRFC), técnica esta que vem sendo executada desde 1980, porém, ainda pouco difundida e estudada no Brasil. Seis vigas, com resistência à compressão do concreto em tomo de 90 :MPa, e, mesma geometria e armaduras, longitudinal e transversal, foram levadas à ruptura por flexão. Uma viga foi considerada como viga padrão e outras cinco foram reforçadas à flexão, por intermédio de mantas de fibras de carbono aderidas às suas faces inferiores. Em três das vigas reforçadas um mecanismo de incremento de ancoragem, nas regiões próximas aos apoios, foi proposto. Os resultados experimentais foram comparados com valores esperados, que por sua vez foram obtidos de acordo com uma metodologia de cálculo à flexão desenvolvida com base no estudo de trabalhos já realizados por outros autores. Os valores dos momentos fletores de início de descolamento da manta, nas vigas sem os laço de ancoragem, também foram confrontados com valores previamente esperados. Foram ainda realizados ensaios de aderência e propostas duas metodologias para o dimensinamento dos mecanismos de melhoria da ancoragem. De acordo com os ensaios realizados pôde-se constatar que a ruptura prematura por descolamento total da manta pode ser evitada pelo mecanismo de ancoragem proposto, sendo que o reforço, pelo próprio arranjo sugerido, além de retardar o início do escoamento da armadura longitudial inferior, atua como alternativa de reforço ao esforço cortante. A resistência última à flexão da viga reforçada com quatro camadas e laços de ancoragem foi aumentada, em relação à viga testemunho, em 157 % / Abstract: The objective of this dissertation is to offer a contribution in the study of the behaviour of high strength reinforced concrete beams with externally bonded carbon fiber reinforced plastic (CFRP) sheets, wich is a technique that has been executed since 1980. Six beams, with concrete strength around 90 :MPa, and with identics geometry and internal reinforcing bars were tested under bending until failure. One specimen was used as a control beam and the other five were strengthened, in flexure, with the use of CFRP sheets bonded to the tension face of the members. In three of the strengthened beams was proposed anchorages at the sheet ends, near the supports. The experimental results were compared with the analytical values. The bending moments registered in the begining of the debonding of the sheets, in the beams with no anchorage systems, were also compared with previously determined values. Aderence tests to verify the quality of the bonding in the interface sheet-concrete and two proposals of calculating methodologies for the anchorage systerns were also conducted. It was seen that the premature debonding of the sheet can be avoided through the use of the anchorage systems proposed, and, this anchorage, because of its design, can also improves the shear capacity of the beams. The results showed an increment in the ultimate flexural resistance of the beam strengthened with four plies, in comparison with the beam with no external reinforcing, of 157 % / Mestrado / Estruturas / Mestre em Engenharia Civil
112

Efeitos de diferentes frequencias semanais de treinamento com pesos sobre a composição corporal e capacidades motoras em homens idosos / Effects of differential weekly frequencies of weight training on body composition and motor capacities in older men

Santos, Claudinei Ferreira dos 03 September 2009 (has links)
Orientador: Mara Patricia Traina Chacon-Mikahil / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Educação Fisica / Made available in DSpace on 2018-08-13T02:56:33Z (GMT). No. of bitstreams: 1 Santos_ClaudineiFerreirados_D.pdf: 5106136 bytes, checksum: 3c8ba3f70ffe0e4630ab7e8c634b98d9 (MD5) Previous issue date: 2009 / Resumo: Os efeitos do treinamento com pesos realizados com diferentes intensidades, freqüências e volumes trazem respostas benéficas e são bem difundidos para populações de jovens e atletas. No entanto, estudos que procuram avaliar os efeitos do treinamento com pesos realizados em diferentes freqüências semanais são escassos para populações idosas. Assim, o propósito da presente pesquisa foi analisar e comparar os efeitos do treinamento com pesos sobre indicadores da sarcopenia, composição corporal, hipertrofia muscular e das capacidades físicas força muscular e flexibilidade de homens idosos submetidos a duas ou três sessões semanais de treinamento com pesos. Para tanto fizeram parte da amostra 27 indivíduos, subdivididos em: grupo treinamento com freqüência semanal de 2 sessões de treino (GT2, n=9), grupo treinamento com freqüência semanal de 3 sessões de treino (GT3, n=10), ambos submetidos a um programa de treinamento com pesos por um período de 16 semanas, e um grupo controle (GC, n=8) que não se envolveu com nenhuma rotina de exercícios físicos durante o período do experimento. Os indicadores da sarcopenia e composição corporal foram determinados por Absortometria Radiológica de Dupla Energia (DEXA). A sarcopenia foi determinada pelo índice relativo de músculo esquelético. Como indicador de hipertrofia muscular, a área de secção transversal do braço (ASTBr) e coxa (ASTCx) foram avaliadas pelo método de ressonância magnética. Os indicadores de força muscular foram determinados pelo teste de uma repetição máxima (1-RM) em três exercícios na sala de treinamento com pesos (supino, leg press e rosca direta). Como indicadores de flexibilidade, sete movimentos articulares foram avaliados por flexímetro. O programa de treinamento com pesos foi dividido em duas etapas, cada qual com oito semanas de duração. Na primeira etapa o protocolo de treinamento foi realizado com cargas fixas (três séries de 15 repetições) com ordem de execução alternada por segmento. A segunda etapa, os exercícios foram localizados por articulação. As diferenças nas etapas objetivam aumentar a magnitude da carga de treinamento progressivamente ao longo do período de estudo. Ajustes semanais nas cargas de treinamento foram realizados observando o princípio da progressão de carga. Foram realizadas análises intra e inter-grupos nos diferentes momentos do estudo. A comparação entre os grupos e os momentos foi realizada pela análise de variância (ANOVA) sendo adotado o nível de significância p<0,05. Os componentes da composição corporal, assim como, o indicador de sarcopenia não foram alterados após o período experimental em nenhum dos grupos. Contudo, diferença significante entre as mudanças percentuais foram observadas entre o GT3 e GC para a gordura corporal relativa e a massa livre de gordura. No teste de 1-RM foram obtidos aumentos significantes na condição pós treino para os exercícios de supino, rosca direta, carga total levantada e carga total levantada relativa a massa corporal para o GT2 e o GT3. Somente o GT3 aumentou significativamente a força muscular no leg press. A evolução semanal da carga de treinamento no exercício supino e rosca direta ocorreu mais acentuadamente para o GT3. Para o exercício de leg press GT2 e GT3 tiveram comportamentos parecidos. Ambos os grupos treinados mostraram aumentos percentuais maiores nos indicadores de flexibilidade para os movimentos de flexão de quadril direito e esquerdo e flexão de ombro esquerdo, quando comparados ao GC. Contudo, somente o movimento de flexão de quadril esquerdo aumentou significativamente para o GT3. Apesar de haver uma tendência ao aumento da ASTCx após o TP para ambos os grupos experimentais, somente houve aumento significativo da ASTBr (9,04%) para o GT3. Diante dos resultados analisados, a realização de três sessões semanais de TP mostrou-se mais efetiva para os grupos de idosos estudados. / Abstract: The effects of weight training made with different intensities, frequencies and volumes provide beneficial answers and are well spread among young people and athletes. However, studies that look for the effects of weight training held at different frequencies weekly are limited to elder populations. So, the purpose of this study was to analyze and compare the effects of weight training on indicators of sarcopenia, body composition, muscle hypertrophy and of the physical capacities of muscular strength and flexibility of elder men submitted to two or three week sessions of weight training. Twenty-seven (27) individuals were part of the sample separated in: group training with two weekly training sessions (TG2, n = 9), group training with three weekly training sessions (TG3, n = 10), both submitted to a weight training for a 16 weeks period, and a control group (CG, n = 8), which was not involved with any exercise routine during the experiment. The indicators of sarcopenia and body composition were determined by Dual Energy X-Ray Absorptiometry (DEXA). The sarcopenia was determined by an index of relative skeletal muscle mass. As an indicator of muscular hypertrophy, the cross-section area of the arm (ASTBr) and thigh (ASTCx) were evaluated by magnetic resonance imaging. The indicators of muscle strength were determined by the test of one maximum repetition (1-RM) in three exercises in the fitness room (bench press, leg press and arm curl). As indicators of flexibility, seven joint movements were evaluated by the fleximeter. The weight-training program was divided into two stages, eight weeks each. The first stage of the training was performed with fixed loads (three sets of 15 repetitions), alternating the order of execution by body segment. On the second stage, the exercises were fixed for articulation. These differences in the stages aimed to increase the load training progressively along the stages. Some adjustments were made weekly in the loads, observing the principle of progressive load. Intra and inter groups' responses were analyzed at different times of the study. The comparison between groups and moments was performed by a variance analysis (ANOVA). The level of significance adopted for all analyses was p<0.05. None of the components of body composition, as well as the indicator of sarcopenia, was changed after the trial period for all groups. However, a significant difference between the changes percentage were observed between TG3 and CG for relative body fat and fat free mass. Significant increases were obtained in the 1-RM test for the bench press, arm curl and full load lifted up and relative load lifted up to the total body mass for the TG2 and TG3 post training. Only TG3 increased significantly muscle strength in the leg press test. The week load evolution in the training was more pronounced in the bench press exercise and the arm curl for the TG3. The leg press performance was similar for TG2 and TG3. Both showed higher increase percentage in indicators of flexibility, in the right and left hip flexion and in the left shoulder, when compared to CG. However, only the left hip flexion increased significantly for the TG3. Despite the tendency of a increasing in the ASTCx in both experimental groups, the significant increase in ASTBr (9,04%) happened only in the TG3. These results showed that the performance of threeweek sessions of TP was more effective for the elder studied group. / Doutorado / Ciencia do Desporto / Doutor em Educação Física
113

Força de preensão e destreza manual na criança com síndrome de Down

Priosti, Paula Aivazoglou 25 August 2009 (has links)
Made available in DSpace on 2016-03-15T19:40:45Z (GMT). No. of bitstreams: 1 Paula Aivazoglou Priosti.pdf: 1014918 bytes, checksum: 04bbafcae5f71527febed1d7ebd89bbd (MD5) Previous issue date: 2009-08-25 / Fundo Mackenzie de Pesquisa / Children with Down Syndrome (DS) show some lateness in getting motor skills that happen in differentiated time to kids with normal development. The main reasons for the lateness in motor development are because the own syndrome characteristics that can interfere in bulk motor activities and finals as the grip strength and manual dexterity. The grip strength analysis and manual dexterity can be considered one of the ways in manual function examination. The motor and sensorial tasks performed by hands are organized to attend the good general body working in practice terms in activities of diary life necessaries to the surviving. The objective of this study was to characterize the grip strength performance and manual dexterity in DS children in age between 7 and 9 years old. The DS group, composed by 26 children in both sexes and also, 30 no DS children composed the control group and they were arranged like the DS children, for age and sex. The valuations of the search subjects were done through the grip strength with dynamometer Jamar and Box and Block Test manual. The results showed that DS group had less practice to control group in grip strength and manual dexterity; there wasn t a significant relationship between grip strength and manual dexterity in DS group; in control group perceived there is a relationship between grip strength and manual dexterity; there wasn t practice difference among the kinds to evaluated items in both groups; the practice to grip strength tests and manual dexterity in control group showed an evolution in de course of age; in DS group, this evolution didn t occur; it was perceived the needing of accomplishment in new studies that getting more specified information about grip strength and manual dexterity in DS.hand strenght, motor skills. / Crianças com Síndrome de Down (SD) apresentam atrasos nas aquisições das habilidades motoras, que ocorrem em tempo diferenciado ao de crianças com desenvolvimento normal. As principais razões pelo atraso no desenvolvimento motor são decorrentes de características da própria síndrome, que podem interferir em atividades motoras grossas e finas, como a força de preensão e a destreza manual. A análise da força de preensão e destreza manual pode ser considerada uma das formas de verificação da funcionalidade manual. As tarefas motoras e sensoriais executadas pela mão são organizadas de forma a atender o bom funcionamento geral do corpo em termos de desempenho, nas atividades de vida diária, necessárias para sobrevivência. O objetivo deste estudo foi caracterizar o desempenho da força de preensão e destreza manual na criança com SD na faixa etária entre 7 e 9 anos. Participaram deste estudo 26 crianças com SD, de ambos os sexos, com idade entre 7 e 9 anos, que constituíram o grupo SD e também 30 crianças sem a síndrome, que compuseram o grupo controle e foram pareadas com o grupo SD por idade e sexo. As avaliações dos sujeitos da pesquisa foram feitas através do teste de preensão manual, com o dinamômetro Jamar e através do Teste da Caixa e Blocos para avaliação da destreza manual. Os resultados mostraram que o grupo com SD apresentou desempenho inferior ao grupo controle tanto na força de preensão quanto na destreza manual; não houve relação significativa entre a força de preensão e a destreza manual no grupo com SD; no grupo controle, percebeu-se que existe essa relação entre força de preensão e destreza manual; não houve diferença de desempenho entre os gêneros para os itens avaliados em ambos os grupos; o desempenho para os testes de força de preensão e destreza manual, no grupo controle, mostrou uma evolução com o decorrer da idade; no grupo das crianças com SD, esta evolução não ocorreu; percebe-se a necessidade da realização de novos estudos que tragam informações mais detalhadas sobre a força de preensão e destreza manual nas crianças com SD.
114

Avaliação da resistência ao cisalhamento de quatro combinações de sistemas adesivos e resinas compostas para fixação de bráquetes ortodônticos

Toledo Júnior, Evane Gonçalves de 21 December 2011 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2016-09-09T18:00:28Z No. of bitstreams: 1 evanegoncalvesdetoledojunior.pdf: 1164428 bytes, checksum: 27c476e8596eb60a8efd9e8c6bfbc052 (MD5) / Approved for entry into archive by Diamantino Mayra (mayra.diamantino@ufjf.edu.br) on 2016-09-13T13:49:48Z (GMT) No. of bitstreams: 1 evanegoncalvesdetoledojunior.pdf: 1164428 bytes, checksum: 27c476e8596eb60a8efd9e8c6bfbc052 (MD5) / Made available in DSpace on 2016-09-13T13:49:48Z (GMT). No. of bitstreams: 1 evanegoncalvesdetoledojunior.pdf: 1164428 bytes, checksum: 27c476e8596eb60a8efd9e8c6bfbc052 (MD5) Previous issue date: 2011-12-21 / Avaliou-se a resistência ao cisalhamento de quatro diferentes combinações de materiais para fixação de bráquetes ortodônticos ao esmalte dental. Utilizou-se 80 incisivos inferiores bovinos divididos em 08 grupos (n=10). Nos grupos G1 e G5 empregou-se um sistema adesivo de três passos + resina composta híbrida; no G2 e no G6 o sistema adesivo de três passos + resina composta híbrida com liberação de flúor; no G3 e no G7 um sistema adesivo autocondicionante + resina composta híbrida; e no G4 e no G8 um sistema adesivo autocondicionante + resina composta híbrida com liberação de flúor, sendo que os grupos G5, G6, G7 e G8 foram submetidos à termociclagem de 1000 ciclos com temperatura variando de 5ºC ±1ºC a 55ºC ±1ºC, com 30s de imersão a cada banho. Em todos os grupos empregou-se bráquetes ortodônticos metálicos Roth Kirium. A seguir realizou-se o teste de cisalhamento em uma máquina de ensaios mecânicos universal a uma velocidade de 1mm/min.. Após esta etapa, o local de fratura foi avaliado ao Microscópio Eletrônico de Varredura (MEV), e as fraturas classificadas em adesiva, coesiva ou mista. Todos os corpos de prova apresentaram fratura do tipo coesiva. Concluiu-se que a superfície do esmalte foi preservada após o teste de cisalhamento e que todas as combinações de materiais testadas apresentaram valores adequados de resistência ao cisalhamento para uso clínico. / This study evaluated the shear bond strength of four different combinations of materials for bonding orthodontic brackets to enamel. Eighty bovine mandibular incisors were used and divided into 08 groups (n = 10). The materials studied were distributed as follows: groups G1 and G5 - three steps primer + hybrid composite; groups G2 and G6 - three steps primer + hybrid composite with fluoride release ; groups G3 and G7- self etching primer + hybrid composite, groups G4 and G8 – self etching primer + hybrid composite with fluoride release. Groups G5, G6, G7 and G8 were thermal cycled for 1000 cycles at temperatures ranging from 5°C ± 1°C to 55ºC ± 1°C, and 30s dip each bath. All groups tested received a metal bracket. The shear test was performed in a universal mechanical testing machine at a speed of 1mm/min and the fracture was assessed by Scanning Electron Microscopy (SEM). Fractures were classified as adhesive, cohesive or mixed. All specimens showed a cohesive fracture type, which preserved the enamel surface after bracket debonding in the shear test. All tested materials presented the shear strength within the clinical limits. After debonding enamel integrity was preserved.
115

Análise dos efeitos do método Pilates em pacientes com fibrose cística / Analysis of the effects of the Pilates method in patients with cystic fibrosis

Franco, Caroline Buarque, 1984- 19 August 2018 (has links)
Orientador: Antonio Fernando Ribeiro / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciências Médicas / Made available in DSpace on 2018-08-19T03:42:04Z (GMT). No. of bitstreams: 1 Franco_CarolineBuarque_M.pdf: 1016164 bytes, checksum: d2defa35883e9f73fc3f033e2ca1c3f1 (MD5) Previous issue date: 2011 / Resumo: Objetivo: A proposta de utilizar o método Pilates teve o objetivo de desenvolver um programa de exercícios, avaliando os efeitos no início e final do acompanhamento, coletando os seguintes dados: tolerância ao esforço físico pelo teste do degrau de 3 minutos (TD3); prova de função pulmonar (PFP); avaliação força muscular respiratória (FMR) pela pressão inspiratória máxima (PImáx) e pressão expiratória máxima (PEmáx) pela manovacuometria; qualidade de vida (QV) pelos questionários de qualidade de vida em fibrose cística (QFC); escore z de peso (kg), escore z de altura (m2) e escore z de IMC (kg/m2). Coleta dos valores em repouso e no final de cada sessão: saturação periférica de oxigênio (SpO2), frequência cardíaca (Fc), frequência respiratória (Fr), nível da dispnéia pela escala de Borg modificada. Método: estudo prospectivo descritivo analítico, casuística de 19 pacientes. A pesquisa foi realizada com os pacientes do Ambulatório de FC do Hospital de Clínicas (HC) da Universidade de Campinas (UNICAMP) e do Instituto da Criança (ICr) do HC da Faculdade de Medicina Universidade de São Paulo (FMUSP). O método foi aplicado em uma sessão semanal durante 4 meses. Resultados: A PImáx no grupo total apresentou aumento significativo (p<0,05 probabilidade do teste de Wilcoxon), a PEmáx demonstrou aumento significativo somente no grupo feminino (p=0,007). A PFP não apresentou diferenças no grupo total de pacientes (p>0,05). No TD3 pré-tratamento do grupo masculino, houve aumento significativo da frequência cardíaca (Fc) (p=0,043) e da escala de Borg (p=0,023). No pós-tratamento os sinais vitais permaneceram sem mudanças significativas. No TD3 pré-tratamento, o grupo feminino apresentou aumento significativo na Fc, frequência respiratória (Fr) e na escala de Borg (p<0,05). No pós-tratamento o TD3 deste grupo continuou com aumento significativo na Fc, Fr e na escala de Borg. Quanto as medidas de sinais vitais comparando o início e final de cada sessão, na 1ª sessão de Pilates o grupo total de pacientes,não apresentou mudanças na SpO2, Fc, Fr e na escala de Borg (p>0,05). Na 7ª sessão, no gênero masculino ocorreu aumento significativo da Fc e no grupo total de pacientes houve aumento significativo na escala de Borg. Na 16ª sessão apenas o grupo feminino apresentou aumento significativo na escala de Borg. Quanto ao escore z de peso e IMC, os pacientes não apresentaram mudanças, porém houve aumento significativo no escore z de altura apenas do grupo feminino (p=0,012). A avaliação da QV não demonstrou mudanças no QFC de crianças de 6 à 11 anos. No QFC dos pais/cuidadores de crianças de 6 à 13 anos houve aumento significativo no domínio respiratório. O QFC referente aos pacientes de 14 anos ou mais apresentou aumento significativo no domínio físico. Conclusões: O estudo evidenciou que a aplicação do Pilates foi eficaz no ganho da FMR; melhorias na tolerância física do grupo masculino pelo TD3; ganho no escore z de altura no grupo feminino. Quanto a QV do QFC dos pais/cuidadores de crianças de 6 à 13 anos, houve melhorias no domínio da condição respiratória e no QFC referente aos pacientes de 14 anos ou mais apresentou melhorias no domínio da condição física / Abstract: Objective: The proposal to use the Pilates method was to develop an exercise program, evaluating the effects at the beginning and end of follow-up by collecting the following data: the tolerance to exercise step test for 3 minutes (TD3) function test lung (PFP), respiratory muscle strength assessment (FMR) by maximal inspiratory pressure (MIP) and maximal expiratory pressure (MEP) by the manometer, quality of life (QOL) questionnaires for quality of life in cystic fibrosis (QFC), z-score Weight (kg), z score for height (m2) and z score of BMI (kg/m2). Collection of the values at rest and at the end of each session: peripheral oxygen saturation (SpO2), heart rate (HR), respiratory frequency (Fr), level of dyspnea by the Borg scale. Method: a prospective descriptive analytical sample of 19 patients. The survey was conducted with patients from the CF Clinic, Hospital de Clinicas (HC), Universidade de Campinas (UNICAMP) and the Instituto da Criança (Chr), HC, Faculdade de Medicina da Universidade de São Paulo (FMUSP). The method was applied to one session per week for four months. Results: MIP in the total group showed a significant increase (p<0.05 probability of the Wilcoxon test), MEP showed an increase only in the female group (p=0.007). The PFP did not show differences in the total group of patients (p>0.05). In TD3 pretreatment of the male group, there was increased heart rate (HR) (p=0.043) and Borg (p=0.023). In the post-treatment vital signs remained without significant changes. No TD3 pretreatment, the female group showed an increase in HR, respiratory frequency (Fr) and the Borg scale (p<0.05). In the post-treatment group continued TD3 this significant increase in HR, Fr and Borg scale. The measures vital signs comparing the beginning and end of each session, a session of Pilates the total group of patients showed no changes in SpO2, HR, Fr and Borg scale (p>0.05). During the 7th session, a significant increase of Fc in males and in the total group of patients showed a significant increase in Borg scale. In the 16th session only female group showed an increase in Borg scale. As for the z scores for weight and BMI, patients had no change, but there was an increase in height z scores in the female group (p=0.012). The assessment of QOL showed no changes in the QFC of children 6 to 11 years. In QFC parents/caregivers of children 6 to 13 years there was an increase in the field related respiratory and QFC in referring to patients 14 years or more, an increase in the physical realm. Conclusions: The study suggested that the use of Pilates has been effective in: gain of FMR, improvements in physical tolerance in male group, gain in height z scores in the female group. As for the QL QFC parents/caregivers of children 6 to 13 years there has been an improvement in respiratory status and QFC referring to patients 14 years or more improvements in physical condition / Mestrado / Saude da Criança e do Adolescente / Mestre em Saude da Criança e do Adolescente
116

CORRELAÇÃO ENTRE GRAU DE CONVERSÃO E RESISTÊNCIA DE UNIÃO DE SISTEMAS ADESIVOS AUTOCONDICIONANTES / CORRELATION BETWEEN DEGREE OF CONVERSION AND BOND STRENGTH OF THE SELF-ETCHING ADHESIVE SYSTEM

Borges, Marciano de Freitas 24 February 2010 (has links)
Objective: The aim of this study was to analyses the relationship between the degree of conversion of double bonds of self-etching adhesives and microshear bond strength on dentin. Materials and methods: For microshear testing twenty third molar caries free were selected. They had their crowns sectioned longitudinally so as to obtain slices that were randomly chosen and divided into four groups according to the adhesive system, Single Bond (SB), Clearfil SEBond (CL) , Adhese (AD) and Gbond (GB). The slices were included into epoxy resin, and then cylindrical restorations were built with an area of 1.0 mm in diameter and 2.0 mm in height, around ten restorations per group, using a starch matrix. After 24 hours the specimens were tested for bond strength. To analyze the degree of conversion of these systems, a drop of adhesive was dispensed on a glass plate and after 20 seconds polymerized, forming a film of adhesive. After 24 hours, these films were pulverized and mixed with potassium bromide, pressed in a hydraulic press to form an insert for analysis with the spectrophotometer - FT-IR. The data of shear bond strength and degree of conversion of each specimen were submitted to ANOVA and Tukey s test (p = 0.05). Results: The SB adhesive system had mean values of bond strength statistically higher than AD and GB, but no statistical difference was found with Cl. Among the self-etching systems, the highest average shear bond strength was achieved with the application of the union CL, followed by GB and AD systems, which were not statistically different. Regarding the degree of conversion, similar statistical results were found for the systems SB and CL, and despite the SB had a higher average it, did not differ from CL. The adhesive system SB and CL showed higher values in AD and GB. The AD, showed values higher than the GB. Conclusion: The degree of conversion is affected by several factors related to the complex mixture of adhesive systems, which somehow contribute to their bond strength. / Objetivo: O objetivo desse estudo foi avaliar o grau de conversão de sistemas adesivos autocondiconantes em dentina e correlacioná-los com a resistência ao teste de microcisalhamento. Materiais e Métodos: Para o ensaio de microcisalhamento foram selecionados vinte terceiros molares livres de cárie, os quais tiveram suas coroas seccionadas longitudinalmente de modo a se obter fatias, que, aleatoriamente, foram divididas em quatro grupos, de acordo com o sistema adesivo uilizado, Single Bond (SB), Clearfil SE Bond (CL), Adhese (AD) e Gbond (GB). As fatias foram incluídas em tubos de PVC com resina acrílica e, em seguida, foram construídas restaurações cilíndricas com uma área de 1,0 mm de diâmetro e 2,0 mm de altura, em torno de dez restaurações por grupo, por meio de uma matriz de amido. Após 24 horas, os corpos de prova foram submetidos ao ensaio de microcisalhamento. Para análise do grau de conversão desses sistemas, uma gota do adesivo foi dispensada sobre uma placa de vidro e, após 20 segundos, foram fotopolimerizadas, formando uma película de adesivo. Após 24h, essas películas foram pulverizadas e misturadas com brometo de potássio, prensadas em prensa hidráulica de modo a formar uma pastilha para análise no espectofotômetro - FT-IR. Os dados obtidos da resistência de união e do grau de conversão foram submetidos à análise de variância e teste de Tukey (p = 0.05). Resultados: O sistema de união SB apresentou valores médios de resistência de união ao microcisalhamento estatisticamente superior AD e GB, mas não apresentou diferença estatística em relação ao sistema Cl. Dentre os sistemas autocondicionantes, as maiores médias no ensaio mecânico foram obtidas com a aplicação do sistema de união CL, seguido pelos sistemas AD e GB, que não foram estatisticamente diferentes entre si. Em relação ao grau de conversão, resultados estatísticos semelhantes foram encontrados para os sistemas SB e CL, que, apesar do SB apresentar uma maior média, não diferiu do CL. O sistema adesivo SB e CL apresentaram valores médios superiores ao AD e GB. O AD, que por sua vez, apresentou valores médios maiores que o GB. Conclusão: O grau de conversão é afetado por diversos fatores relacionados à mistura complexa dos sistemas adesivos, que, de certo modo, repercutirá na sua resistência de união.
117

Influencia dos modos de ativação no grau de conversão, resitencia e morfologia da interface de união de sistemas de cimentação e adesivos / Effect of different activation modes on the degree of conversion, tensile bond strength and interfacial morphology of dual-cured cementing systems used in indirect composite restorations

Arrais, Cesar Augusto Galvão 14 December 2006 (has links)
Orientador: Marcelo Giannini / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Ondontologia de Piracicaba / Made available in DSpace on 2018-08-08T01:52:29Z (GMT). No. of bitstreams: 1 Arrais_CesarAugustoGalvao_D.pdf: 8768801 bytes, checksum: bf5f97c936134b9476bb797b23d446d6 (MD5) Previous issue date: 2006 / Resumo: A não fotoativação do sistema adesivo previamente à aplicação do cimento resinoso tem sido proposta quando sistemas de cimentação de dupla ativação (SCDA - sistemas adesivos de dupla ativação / cimentos resinosos de dupla ativação) são utilizados. Entretanto, existe uma carência de relatos científicos a respeito da efetividade dos SCDA. Os objetivos deste estudo foram: 1- avaliar a resistência de união (RU) e a morfologia da interface de união de restaurações indiretas de compósito através da utilização da microscopia confocal laser quando os sistemas adesivos de dupla ativação foram ou não fotoativados previamente à aplicação dos cimentos resinosos; 2- analisar o grau de conversão (GC), através da Espectroscopia Infravermelha Transformada de Fourier (FTIR), e a RU de SCDAs quando a fotoativação não foi realizada ou atenuada pela presença da restauração indireta; 3- avaliar o GC e resistência coesiva de sistemas de união quando utilizados diferentes unidades de fotoativação (LEDs e de luz halógena). A RU e resistência coesiva foram avaliadas através do ensaio de microtração. Para a análise em microscopia confocal laser, diferentes corantes foram incorporados nos SCDAs previamente à sua aplicação. Para a análise do GC, os SCDAs foram aplicados na superfície do diamante da unidade de reflectância total atenuada acoplada ao espectrômetro infravermelho. O GC dos sistemas de união não relacionados aos SCDAs foi obtido utilizando-se filmes de resina adesiva. Os resultados demonstraram que a não fotoativação do sistema adesivo de dupla ativação previamente à cimentação não afetou a RU, e que os valores foram até superiores para um SCDA de 4ª geração quando o agente de união não foi fotoativado. A análise em microscopia confocal laser exibiu variação nas características morfológicas da interface de união, variando de acordo com o SCDA utilizado e com o modo de ativação de ambos componentes (sistema adesivo e cimento resinoso). Para alguns SCDAs, o GC foi reduzido pela presença do disco de compósito posicionado entre o SCDA e a ponta da unidade fotoativadora. A não fotoativação dos SCDAs resultou em GC inferiores aos obtidos com exposição direta da luz. A não fotoativação da maioria dos SCDAs também resultou em valores inferiores de RU, exceto quando um sistema de 4ª geração foi utilizado. A utilização de LED resultou em GC inferior ao obtido quando a luz halógena foi utilizada mas não afetou a resistência coesiva dos sistemas adesivos avaliados. Pode-se concluir que a não fotoativação dos sistemas adesivos é uma alternativa aceitável durante a cimentação de restaurações indiretas, porém os SCDAs necessitam de luz fotoativadora para garantir adequada RU. A utilização de LEDs pode comprometer o GC dos sistemas adesivos / Abstract: The lack of light-activation of dual-cured bonding agents before the resin cement application has been an alternative technique of cementing indirect restorations when dual-cured cementing systems are used (DCS ¿ dual-cured bonding agents / dual-cured resin cements). However, few reports exist regarding the effectiveness of DCS when dual-cured bonding agents are left in the uncured state before the seating of the indirect restoration. Therefore, the aims of this study were: 1- to evaluate the microtensile bond strength (MTBS) and micromorphology of the adhesive interface of indirect restorations by confocal laser microscopy (CLSM) when the dual-cured bonding agents were left in the uncured state; 2- to analyze the degree of conversion (DC) by Fourier Transformed Infrared Spectroscopy and the bond strength of indirect restorations when DCSs were applied to the tooth and light activated or allowed to self-cure; 3- to evaluate the DC and ultimate tensile strength (UTS) of bonding agents light-activated with light curing units (LEDs and halogen light). The MTBS and UTS were analyzed using microtensile bond strength test. Different dyes were incorporated to the DCSs before they were applied to teeth for the CSLM analysis. For the DC analysis, the DSCs were applied to the diamond surface of attenuated total reflectance unit of the infrared device. The DC of the bonding agents related to the study evaluating the effectiveness of light-curing units was obtained from thin resin adhesive films. The results demonstrated that the MTBS was not affected, and the values were even higher for one 4th generation DCS, when the dual-bonding agents were left in the uncured state before the resin cement application. The CLSM analysis exhibited some variation in the micromorphological features, which depended on the DCSs and on the curing modes of bonding agents and resin cements. Some DCSs showed lower DC when pre-cured resin composite discs were used. The self-cured groups exhibited lower MTBS than the light-activated ones, except for one 4th generation DCS. The LED promoted lower DC in all bonding agents than did the halogen light. No difference in UTS was observed when LED was used. It was concluded that leaving the dual-cured bonding agent in the uncured state before seating the indirect restoration may be a reliable technique to ensure adequate MTBS, but most DCSs should be light-activated after seating the indirect restoration to provide optimal bond strength. Some LEDs can compromise the DC of adhesive systems / Doutorado / Dentística / Doutor em Clínica Odontológica
118

Cimentos resinosos convencionais e autoadesivos = caracterização das partículas de carga, ultramorfologia e resistência da união resina-dentina / Conventional and self-adhesive resin cements : filler particles characterization, ultramicromorphology and dentin-resin bond strenght

Aguiar, Thaiane Rodrigues 18 August 2018 (has links)
Orientador: Marcelo Giannini / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-18T10:52:55Z (GMT). No. of bitstreams: 1 Aguiar_ThaianeRodrigues_D.pdf: 24572936 bytes, checksum: 8141f58fcbce6835d1091f52127552a7 (MD5) Previous issue date: 2011 / Resumo: O emprego dos cimentos resinosos na fixação de peças protéticas têm sido avaliado em muitos estudos, entretanto, trabalhos que simulem os desafios presentes na cavidade bucal e o comportamento a longo prazo dos cimentos resinosos autoadesivos ainda são escassos na literatura. Diante disso, o presente estudo teve como objetivo: 1) verificar a composição inorgânica das partículas de carga e caracterizá-las quanto ao tipo e morfologia; 2) analisar a ultramorfologia da interface de união dentina-cimento resinoso através da microscopia confocal por varredura a laser e da microscopia eletrônica de varredura (MEV); 3) avaliar o efeito do armazenamento por 1 ano ou da ciclagem mecânica (50.000 ciclos) na resistência de união dentina-cimento resinoso. Quatro cimentos resinosos foram avaliados: dois autoadesivos (RelyX Unicem, 3M ESPE e Clearfil SA Luting, Kuraray Medical Inc.) e dois convencionais (RelyX ARC/Adper Scotchbond Multi-Purpose Plus, 3M ESPE e Clearfil Esthetic Cement/Clearfil DC Bond, Kuraray Medical Inc.). Para analisar os principais componentes inorgânicos e avaliar as características das partículas de carga, o conteúdo orgânico dos cimentos resinosos foi removido por solventes orgânicos e as amostras analisadas em MEV/EDX (Espectroscopia de energia dispersiva por raios-X). Terceiros molares humanos foram utilizados na avaliação da ultramorfologia da interface dentina-cimento resinoso e no ensaio de resistência de união à dentina. Na análise da ultramorfologia da área de união, corantes (fluoresceína e rodamina) foram previamente adicionados aos materiais estudados para possibilitar a obtenção das imagens. Para o ensaio de resistência de união, discos de resina composta indireta foram confeccionados visando simular as restaurações indiretas. Após a cimentação, os dentes restaurados foram submetidos a três tratamentos e ao ensaio de microtração: 1- espécimes testados após 24 h (grupo controle); 2- ciclagem mecânica e em seguida testados; 3- armazenados em saliva artificial por 1 ano na forma de "palitos" e testados. Os dados obtidos a partir do ensaio de resistência de união foram analisados estatisticamente (ANOVA e teste Tukey, p<0,05). Nos outros dois estudos, a análise descritiva dos dados obtidos a partir das imagens microscópicas foi realizada. Na avaliação MEV/EDX notou-se elevado conteúdo de silício em todos os materiais. O cimento RelyX ARC apresentou partículas de carga esféricas e irregulares, enquanto os outros materiais demonstraram partículas com formato irregular. Nas fotomicrografias, a hibridização dentinária somente foi observada para os sistemas de cimentação convencional. No ensaio de resistência de união, os tratamentos não influenciaram a resistência de união dos cimentos resinosos à dentina. Os cimentos autoadesivos apresentaram médias de resistência de união significantemente superiores aos chamados convencionais. Embora os materiais avaliados apresentem partículas de carga com distintas composições inorgânicas e interagem com a dentina através de diferentes mecanismos, os tratamentos de envelhecimentos propostos não reduziram a resistência de união à dentina, quando comparados ao grupo controle. Os cimentos autoadesivos não formam camada híbrida na dentina intertubular, nem tags de resina nos túbulos dentinários, entretanto, apresentam partículas de carga com maior tamanho e demonstraram os maiores valores médios de resistência de união à dentina entre os cimentos estudados / Abstract: Resin luting materials to fixed prosthetic restorations have been evaluated in many studies, however, little is known about self-adhesive resin cements, mainly involving long-term durability and when these materials have been submitted to challenges of oral environment. Thus, the purpose of this study was: 1- to verify the filler particles components and to characterize them according to type and morphology; 2- to analyze the ultramorphology of the dentin-resin interfaces using confocal laser scanning microscopy and scanning electron microscopy (SEM) and 3- to evaluate the effect of the storage for 1 year or the mechanical cycling (50.000 cycles) on bond strength of resin cements to dentin. Four resin cements were used in this study: two self-adhesive resin cements (RelyX Unicem, 3M ESPE and Clearfil SA Luting, Kuraray Medical Inc.) and two conventional resin cements (RelyX ARC/Adper Scotchbond Multi- Purpose Plus, 3M ESPE and Clearfil Esthetic Cement/Clearfil DC Bond, Kuraray Medical Inc.). For indentifying the main inorganic components and to evaluate the filler particles characteristics, the organic phase of resin cements was removed using organic solvents and the sample was analyzed by SEM/EDX (Energy-dispersive X-ray spectroscopy). Human third molars were used for micromorphology analysis of resin-dentin interfaces and microtensile bond strength test. For micromorphology analyses of resin-dentin interfaces, two fluorescent dyes (fluorescein and rhodamine B) were incorporated into the materials previously. For microtensile bond strength, pre-polymerized resin discs were prepared to simulate indirect restorations. After bonding procedures, the restored teeth were submitted to three treatments: 1- control group (tested 24 h after specimen preparation); 2- tested after mechanical cycling; 3- beams were storage for one year in artificial saliva and tested. Bond strength data were statistically analyzed by two-way ANOVA and Tukey test (?<0.05). Qualitative analysis was performed for two other studies using microscopic images. For SEM/EDX measurements, high amount of silicon was identified for all cements. The resin cement RelyX ARC showed spherical and irregular particles, while other cements presented irregular shape fillers. Hybrid layer formation was observed only for conventional resin cements in micromorphology analyses. For microtensile test, the treatments did not reduce the bond strength between dentin-resin cement. Self-adhesive resin cements provide significantly higher bond strength than those conventional materials. Despite the resin cements showed filler particles with differences in the inorganic composition and different bonding mechanisms, the mechanical cycling and storage for one year did not affect the bond strength to dentin when it was compared to control group. The self-adhesive resin cements showed no hybrid layer formation in intertubular dentin and nor resin tags in the dentinal tubules were detected. However, these materials showed the biggest filler particles and higher bond strength to dentin than conventional resin cements studied / Doutorado / Dentística / Doutor em Clínica Odontológica
119

Krásné bohyně: současná feminní spiritualita na příkladu ženské tantrické skupiny / Beautiful Goddess: Contemporary Feminine Spirituality in the example of the female tantric groups

Veselá, Helena January 2010 (has links)
This thesis elaborates the results of the research I carried out wtihin the year 2009 in a paid course of female tantric initiation. The theme of the thesis was inspired by my previous interest in the Goddess movement. As this movement is not yet concretized in the Czech republic, I have chosen participating in a closed women's group which is very close to it due to a specific combination of religion, philosophy and psychology. My goal was to find out what form the women's spirituality has in the Czech environment and what kind of women are drawn to it. While the first part of the thesis deals with the universal characteristics of the current eclectic spirituality generally described as the New Age movement, the second part is devoted to the research itself. I come to the conclusion that the symbol of the Goddess, the key idea of the thesis, is not perceived only as a religious concept but also as a medium by means of which women define their needs and problems resulting from their femininity. By this particular case, I advert to the very psychotherapeutic dimension of women's spirituality. Keywords: New Age, tantra, The Goddess, body, spirituality, femininity, self-realization, strength, motherhood
120

Vliv druhu a dávky rozptýlené výztuže na vybrané vlastnosti betonu. / Effect of type and dose of scattered reinforcement on selected properties of concrete.

Láníková, Lucie January 2013 (has links)
The Master’s thesis is focused on the research influence the dose and type of scattered reinforcement in a reference concrete on physical and mechanical properties of the resulting composite. The investigated properties of composite belongs compressive strength, tensile strength in the flexural and tensile strength in the transverse, static modulus of elasticity in compressive strength, dynamic modulus of elasticity determined using NDT tests. The reference concrete mixture is certified as structural concrete of the class, which is commonly used on construction sites.

Page generated in 0.0617 seconds