• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 92
  • 86
  • 13
  • 8
  • 5
  • 5
  • 4
  • 3
  • 3
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 299
  • 135
  • 75
  • 65
  • 46
  • 46
  • 46
  • 39
  • 33
  • 32
  • 32
  • 32
  • 29
  • 29
  • 29
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Tratamento biomimético de discos e implantes de titânio com alendronato : caracterização topográfica, estudo histométrico e imunoistoquímico em coelhos /

Figueira Júnior, Heldo Cesar. January 2018 (has links)
Orientador: Idelmo Rangel Garcia Junior / Coorientadora: Roberta Okamoto / Banca: Francisley Ávila Souza / Banca: Leonardo Perez Faverani / Banca: Vilmar Devanir Gottardo / Banca: André Luís da Silva Fabris / Resumo: Tratamentos de superfície de materiais implantáveis no corpo humano são analisados incansavelmente dentro das áreas da saúde. É comum ser observado em artigos científicos o emprego de um recente e desconhecido biomaterial sendo analisado para este fim. O objetivo deste estudo foi avaliar o emprego do alendronato sobre a caracterização topográfica de implantes e discos de titânio in vitro, e sobre a superfície de implantes de titânio inseridos em coelhos após levantamento de seio maxilar, correlacionando as respostas biológicas e físicas do tratamento comparadas a protocolos bem estabelecidos da implantodontia. Utilizou-se seis discos e vinte e seis implantes dentários ambos de titânio comercialmente puro. Para as análises topográficas, discos e implantes se dividiram em 2 grupos de 3 amostras: Grupo CTL, submetidos a subtração ácida e grupo ALD, submetidos a tratamento biomimético com alendronato. Para os testes em animais, 5 implantes foram distribuídos por grupo, CTL e ALD, com intervalos de eutanásia de 7 e 40 dias. Após microscopia eletrônica de varredura, análise de espectroscopia por energia dispersiva, análise do ângulo de contato com a água, de energia livre de superfície e da presença de sítios doares de elétrons (base de Lewis), os grupos ALD apresentaram resposta satisfatória frente aos processos aceitos em saúde, sendo superiores em todas as análises. A resposta histométrica também foi mensurada resultando em maior tecido ósseo nas análises ELCOI e AON nos grupos ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Surface treatments of implantable materials in the human body are analyzed tirelessly within the health areas. It is common to observe in scientific articles the use of a recent and unknown biomaterial being analyzed for this purpose. The objective of this study was to evaluate the use of alendronate on the t opographic c haracterization of implants and titanium discs in vitro, and over the surface of titanium implants inserted into rabbits after maxillary sinus lift, correlating the biological and physical responses of the treatment compared to well established implantology protocols. It was used six disks and twenty - six commercially pure titanium dental implants. For the topographic analyzes, disks and implants were divided into 2 groups of 3 samples: CTL group, submitted to acid subtraction and ALD group, submi tted to biomimetic treatment with alendronate. For the animal tests, 5 implants were distributed per group, CTL and ALD, with euthanasia intervals of 7 and 40 days. After scanning electron microscopy, analysis of energy dispersive spectroscopy, analysis of the water contact angle, free surface energy and the presence of electron ́s donor sites (Lewis base), the ALD groups showed a satisfactory response to the accepted processes in health, being superior in all the analyzes. The histometric response was also measured resulting in increased bone tissue in the ELCOI and AON analyzes in the ALD 40 days' group. The discrete presence of TRAP at 40 days refers to low bo... (Complete abstract click electronic access below) / Doutor
52

Influência do desing, tratamento de superfície e densidade do substrato na estabilidade primária de implantes odontológicos. Análise por meio de torque de inserção, resistência ao arrancamento e freqüência de ressonância / Influence of the desing, surface treatment and substrate density on the primary stability of dental implants. Analysis using insertion torque, pull-out strength and resonance frequency.

Oliscovicz, Nathalia Ferraz 14 December 2011 (has links)
A grande variedade de modelos de implantes disponíveis no mercado, assim como a variabilidade óssea nos pacientes, torna cada vez mais difícil a seleção do implante que permita obter uma maior estabilidade primária, fator essencial para osseointegração. O objetivo desse trabalho foi avaliar a influência do formato e tratamento de superfície de implantes, assim como do substrato utilizado, na estabilidade primária; aferida por meio de ensaios de desempenho e freqüência de ressonância. Foram utilizados 32 implantes Conexão®: 8 implantes cilíndricos hexágono externo sem tratamento de superfície (MS), 8 cilíndricos hexágono externo com tratamento Porous duplo (MP), 8 cilíndricos hexágono interno com tratamento Porous (CA), 8 cônicos sem tratamento (CC); todos com 11,5 mm de comprimento, e 3,75 mm de diâmetro para cilíndricos e 3,5 mm para os cônicos. Foram inseridos em diferentes substratos: osso de costela suína; osso artificial de poliuretana Synbone©; poliuretana Nacional® em três densidades - 15, 20 e 40 PCF; e madeira pinus. Para o ensaio de desempenho foi quantificado o torque de inserção com o torquímetro digital Mackena®, e a força de arrancamento por meio de força axial de tração com célula de carga de 200 kg, realizada na Máquina Universal de Ensaios Emic® DL-10000, e Software Tesc 3.13. A análise da freqüência de ressonância foi realizada com o aparelho Osstell Mentor®. Para obtenção dos resultados estes receberam tratamento estatístico ANOVA e Teste de Tukey com nível de significância a 5%. Ao analisar o torque de inserção, implantes com tratamento de superfície não foram diferentes estatisticamente do usinados, assim como os implantes cilíndricos não tiveram diferença estatística com os cônicos em todos os substratos (P>0,05), com exceção da poliuretana Synbone©, onde os cônicos apresentaram a menor média (4.45 ± 0.82) e tiveram diferença estatistica com os cilíndricos, hexágono externo (MP= 11.39 ± 0.76; MS= 10.34 ± 1.68), e interno (12.18 ± 3.78). No osso suíno, na poliuretana Nacional® de 15 PCF e na madeira, os implantes cônicos mostraram um melhor desempenho que nos outros substratos. Da mesma forma que no torque de inserção, em relação à força máxima de arrancamento, implantes tratados e usinados, assim como cônicos e cilíndricos, não tiveram diferença estatística (P>0,05), em todos os substratos; implantes cônicos só não apresentaram menores médias de força de arrancamento em matérias menos densos - osso suíno (138.19 ± 57.41 N), poliueretana Nacional® de 15 (209.57 ± 9.60 N) e 20 PCF(206.57 ± 31.51 N); e implantes cilindricos hexágono interno mostraram a maior média numérica em todos os materiais de inserção. Os valores de freqüência de ressonância mostraram que, apesar dos implantes com tratamento de superfície apresentarem maior média de ISQ que os implantes usinados em todos os substratos, estes não apresentaram diferença estatística entre si (P>0,05), com exceção da inserção na poliuretana Nacional de 20 PCF. Pôde-se concluir que, tanto o formato, como o tratamento de superfície dos implantes não influenciaram nas análises realizadas, entretanto, o substrato utilizado e sua densidade tiveram uma maior influência nos resultados obtidos. / The great variety of implant models available in the market, as well as the variability of patients bones, makes the selection of the implant that allows greatest primary stability, an essential factor for osseointegration, increasingly difficult. The aim of this study was to evaluate the influence of the format and surface treatment of implants, as well as the substrate used in primary stability; verified through resonance frequency and performance tests. 32 Conexão® implants were used: 8 cylindrical external hexagon implants without surface treatment (MS), 8 cylindrical external hexagon implants with double Porous treatment (MP), 8 cylindrical internal hexagon implants with Porous treatment (CA), and 8 tapered implants without treatment (CC). All had a length of 11.5 mm, while the cylindrical ones had a of diameter 3.75 mm compared with 3.5 mm for the tapered ones. They were inserted in different substrates: pig rib bone; artificial bone made from polyurethane Synbone©; Nacional® polyurethane in three densities - 15, 20 and 40 PCF; and pinus wood. For the performance test the insertion torque (N.cm) was quantified using the digital Mackena® torque meter, and the pull-out force (N) by means of axial traction force with a 200 kg load cell, carried out in the Emic® DL-10000 Universal Test Machine and the Tesc 3.13 software. The analysis of the resonance frequency (ISQ) was carried out with the Osstell Mentor® device. To obtain the results the ANOVA and Tukey statistical tests were used with a level of significance 5%. When analyzing the insertion torque, implants with surface treatment were not statistically different from the machined ones, nor did the cylindrical implants have any statistical difference from the tapered ones in all the substrates (P> 0.05), with exception of polyurethane Synbone©, where the tapered ones had a lower average (4.45 ± 0.82) and a statistical difference from the external hexagon (MP= 11.39 ± 0.76; 10.34 MS= ± 1.68), and internal hexagon (12.18 ± 3.78) cylindrical ones. In the pig bone, the 15 PCF Nacional® polyurethane and the wood tapered implants had a better performance that in the other substrate. Similar to the insertion torque, treated and machined implants, and tapered and cylindrical, did not have any statistical difference (P>0.05) in all the substrates; tapered implants only did not have a lower average of pull-out except in less dense substrates pig bone (138.19 ± 57.41 N), 15 Nacional® polyurethane (209.57 ± 9.60 N) and 20 PCF (206.57 ± 31.51 N). Internal cylindrical hexagon implants had the highest numerical average of all the inserted materials. The resonance frequency values showed that although the implants with surface treatment had a greater average ISQ that the machined implants in all the substrates, there was no statistical difference between them (P> 0.05), with the exception of the insertion of 20 PCF Nacional® polyurethane. It can be concluded that both the format and surface treatment of implants did not influence the analyses, however, the substrate used and their densities had a bigger influence on the results obtained.
53

Functional and nutritional characteristics of Bambara groundnut milk powder as an ingredient in yoghurt

Hardy, Zolelwa January 2016 (has links)
Thesis (MTech (Food Technology))--Cape Peninsula University of Technology, 2016. / The aim of this study was to evaluate Bambara groundnut (BGN) milk subjected to spray drying with a view to establish functional, nutritional and physical properties as an ingredient in BGN yoghurt production. BGN milk powder (BGNMP) was successfully produced employing the spray drying technology. Maltodextrin was used as the drying carrier to elevate total solids of BGNM prior to spray drying. There were three levels of maltodextrin (5, 10 and 15%) employed and 10% was ideal. The optimum spray drying parameters were estimated to be the following; inlet temperature (150oC), outlet temperature (74oC), air pressure (3 bars), flow rate (10% or 16mL/min), and air flow (42.9 m3/h). The functional properties evaluated revealed high water solubility capabilities, making BGNMP readily soluble in water, which is one of the most crucial aspects of milk powders. The water solubility index of BGNMP at all maltodextrin levels ranged from 85.15 to 90.25%. There was a significant (p < 0.05) difference amongst BGNMP (5, 10, and 15%) in colour parameters (lightness, yellowness, redness, chroma and hue angle). BGNMP indicated to have a red and yellow colour, but yellow was more dominant. The particle size and particle size distribution of BGNMP ranged from 86.13 to 162.35 μm and 84.04 to 157.0 μm, respectively and did not differ significantly (p > 0.05).
54

Highly silicated hydroxyapatite : synthesis, characterisation and evaluation

Conway, Jordan C. January 2017 (has links)
No description available.
55

Biosynthesis, characterization and implantation of artificial growth plate using 3-D chondrocyte pellet culture.

January 1998 (has links)
by Cheng Sze Lok, Alfred. / Thesis (M.Phil.)--Chinese University of Hong Kong, 1998. / Includes bibliographical references (leaves 104-109). / Abstract also in Chinese. / DECLARATION --- p.i / ABSTRACT --- p.ii / ACKNOWLEDGEMENT --- p.vii / ABBREVIATIONS --- p.ix / LIST OF FIGURES --- p.x / LIST OF TABLES --- p.xii / TABLE OF CONTENTS --- p.xiii / Chapter CHAPTER ONE 226}0ؤ --- INTRODUCTION / Chapter 1.1 --- The Growth Plate / Chapter 1.1.1 --- "Function, Structure and Biochemistry of the Growth Plate" --- p.1 / Chapter 1.1.2 --- Extracellular Matrix of the Growth Plate Cartilage --- p.4 / Chapter 1.1.3 --- Vascular Supply to the Growth Plate --- p.9 / Chapter 1.1.4 --- Endochondral Ossification --- p.10 / Chapter 1.2 --- Growth Plate Damage and the Contemporary Reconstruction Models --- p.13 / Chapter 1.3 --- The 3-D Chondrocyte Pellet Culture --- p.15 / Chapter 1.4 --- The Study Plan --- p.16 / Chapter 1.5 --- The Objectives of the Study --- p.18 / Chapter CHAPTER TWO 一 --- METHODOLOGY / Chapter 2.1 --- Biosynthesis of Artificial Growth Plate using 3-D Chondrocyte Pellet Culture / Chapter 2.1.1 --- Isolation of Rabbit Costal Resting Chondrocytes --- p.19 / Chapter 2.1.2 --- Chondrocyte Monolayer Culture --- p.20 / Chapter 2.1.3 --- Three-dimensional Chondrocyte Pellet Culture --- p.20 / Chapter 2.1.4 --- Optimization of 3-D Chondrocyte Pellet Culture System --- p.20 / Chapter 2.2 --- Characterization of the 3-D Chondrocyte Pellet Culture and Monolayer Culture / Chapter 2.2.1 --- Histomorphology --- p.22 / Chapter 2.2.2 --- Alkaline Phosphatase Histochemistry --- p.22 / Chapter 2.2.3 --- Collagen Typing --- p.23 / Chapter 2.2.3.1 --- Labeling and extraction of newly synthesized collagen / Chapter 2.2.3.2 --- SDS-PAGE and autoradiography / Chapter 2.2.4 --- Growth Rate --- p.25 / Chapter 2.2.4.1 --- Total DNA content determination / Chapter 2.2.4.2 --- Thymidine incorporation assay / Chapter 2.3 --- Implantation of Artificial Growth Plate and Assessment / Chapter 2.3.1 --- Implantation of Artificial Growth Plate into Partial Growth Plate Defect Model --- p.27 / Chapter 2.3.1.1 --- Animals / Chapter 2.3.1.2 --- Surgical procedure / Chapter 2.3.1.3 --- Experimental groups / Chapter 2.3.2 --- Histology --- p.30 / Chapter 2.3.3 --- Metabolism of Artificial Growth Plate In Vivo --- p.31 / Chapter 2.3.3.1 --- Radio sulfate labeling / Chapter 2.3.3.2 --- Liquid emulsion and autoradiography / Chapter CHAPTER THREE 一 --- RESULTS / Chapter 3.1 --- Biosynthesis of Artificial Growth Plate using 3-D Chondrocyte Pellet Culture / Chapter 3.1.1 --- Morphology of the Isolated Rabbit Chondrocyte --- p.32 / Chapter 3.1.2 --- Three-dimensional Chondrocyte Pellet Culture --- p.32 / Chapter 3.1.3 --- Optimization of 3-D Chondrocyte Pellet Culture System --- p.35 / Chapter 3.2 --- Characterization of the 3-D Chondrocyte Pellet Culture and Monolayer Culture / Chapter 3.2.1 --- Histomorphology --- p.38 / Chapter 3.2.2 --- Alkaline Phosphatase Histochemistry --- p.43 / Chapter 3.2.3 --- Collagen Typing --- p.47 / Chapter 3.2.4 --- Growth Rate --- p.50 / Chapter 3.2.4.1 --- Total DNA content determination / Chapter 3.2.4.2 --- Thymidine incorporation assay / Chapter 3.3 --- Implantation of Artificial Growth Plate and Assessment / Chapter 3.3.1 --- Histology --- p.54 / Chapter 3.3.2 --- Metabolism of Artificial Growth Plate In Vivo --- p.65 / Chapter CHAPTER FOUR 一 --- DISCUSSION / Chapter 4.1 --- Optimal Condition for 3-D Chondrocyte Pellet Culture System --- p.67 / Chapter 4.1.1 --- Some Critical Characteristics of the Growth Plate --- p.68 / Chapter 4.1.2 --- Selection of Animal Model --- p.69 / Chapter 4.1.3 --- Optimization of Culturing Conditions 226}0ؤ Screening Based on Morphological Studies --- p.69 / Chapter 4.2 --- Characterization of the 3-D Chondrocyte Pellet Culture and Monolayer Culture --- p.73 / Chapter 4.2.1 --- Development of the 3-D Chondrocyte Pellet Culture --- p.73 / Chapter 4.2.2 --- Development of the Chondrocyte Monolayer Culture --- p.78 / Chapter 4.2.3 --- Comparing the 3-D Chondrocyte Pellet Culture and Monolayer Culture --- p.79 / Chapter 4.2.3.1 --- Cellular organization / Chapter 4.2.3.2 --- Terminal differentiation of chondrocytes / Chapter 4.2.3.3 --- Cell division potential / Chapter 4.2.3.4 --- Production of cartilaginous matrix / Chapter 4.3 --- Resumption of Physeal Characteristics by Artificial Growth Plate In Vivo --- p.86 / Chapter 4.3.1 --- Three Stages of In Vivo Development of the Artificial Growth Plate --- p.86 / Chapter 4.3.1.1 --- Incorporation of artificial growth plate with host tissues / Chapter 4.3.1.2 --- Growth of the artificial growth plate invivo / Chapter 4.3.1.3 --- Resumption of endochondral ossification in the artificial growth plate / Chapter 4.3.2 --- Significance of Development of the 3-D Pellet Culture on its In Vivo Development --- p.89 / Chapter 4.3.2.1 --- 3-D pellet culture processes similar extracellular matrix with host / Chapter 4.3.2.2 --- 3-D pellet culture acquires growth plate-like cellular organization and differentiation pattern / Chapter 4.3.3 --- Effect of Host Microenvironment on Artificial Growth Plate Development --- p.90 / Chapter 4.3.3.1 --- Orientation of artificial growth plate implants / Chapter 4.3.3.2 --- Evidence from development of 3-D pellet culture in longer period of culture / Chapter 4.4 --- Comparison with other Growth Plate Reconstruction Models --- p.93 / Chapter 4.4.1 --- Implantation of Biologic or Inert Fillers --- p.93 / Chapter 4.4.2 --- Physeal Transplantation --- p.94 / Chapter 4.4.3 --- Transplantation of Cartilage Allografts --- p.95 / Chapter 4.4.4 --- Transplantation of High-density Chondrocyte Culture --- p.96 / Chapter CHAPTER FIVE 一 --- SUMMARY AND CONCLUSION --- p.98 / Chapter CHAPTER SIX 一 --- FURTHER STUDIES --- p.102 / REFERENCES --- p.104
56

Estudo comparativo do processo de reparo utilizando osso autógeno e beta-tricálcio fosfato em levantamento do assoalho do seio maxilar em humanos : análise tomográfica, histológica, histométrica e imunoistoquímica /

Boos, Fernanda Brasil Daura Jorge. January 2014 (has links)
Orientador: Eduardo Hochuli Vieira / Banca: Idelmo Rangel Garcia Júnior / Banca: Lenadro Eduardo Klüppel / Resumo: Os autores tiveram como objetivo neste trabalho avaliar comparativamente o comportamento do beta-tricalcio fosfato (β-TCP) ChronOs® e do osso autógeno (OA) em seios maxilares por meio de análise tomográfica, histológica, histométrica e imunoistoquímica. Para o presente estudo foram realizados levantamento e preenchimento do assoalho do seio maxilar unilateralmente com OA em 12 seios e com β-TCP puro em 11 seios maxilares. Nos períodos de 07 dias e 06 meses, os pacientes foram submetidos à tomografia para análise quantitativa do volume residual de enxerto após reabsorção e remodelação. Previamente à instalação dos implantes, foram realizadas perfurações com broca trefina para coleta do material e envio para análises. Na análise volumétrica não houve diferença estatisticamente significante entre os grupos. A análise histológica evidenciou presença de grânulos sendo absorvidos e substituídos e tecido ósseo maduro no grupo teste. A quantidade de tecido ósseo neoformado foi maior no grupo do biomaterial. A análise imunoistoquímica comprovou a capacidade osteoindutiva do osso autógeno, não presente no grupo teste. Em conclusão, o ChronOs®, é um material biocompatível e osteocondutor com resultados clínicos similares ao osso autógeno neste modelo de estudo proposto, mesmo sem apresentar capacidade osteoindutiva. / Abstract: The aim of this study was to analyze the behavior of the beta-tricalcium phosphate (β-TCP) ChronOs® and autogenous bone (AB) in maxillary sinus floor augmentation by comparing computed tomography (CT), histological, histometric and immunohistochemical analysis. For this study, grafting of the maxillary sinus was performed unilaterally with AB in 12 sinuses and with pure β - TCP in 11 maxillary sinuses. In periods of 07 days and 06 months, patients underwent CT for quantitative comparative analysis of residual volume after graft resorption and remodeling. Prior to implant placement, drilling with trephine for material collection and analyzes were performed. In CT volumetric analysis there was no statistically significant difference between groups. Histological analysis revealed the presence of granules being absorbed and substituted and mature bone in the β - TCP group. The amount of newly formed bone was also higher in the test group. Immunohistochemical analysis confirmed the osteoinductive capacity of AB group, not seen in the β - TCP group. In conclusion, Chronos® is a biocompatible and osteoconductive material with similar clinical results to the autogenous bone in this proposed model, even without osteoinductive properties. / Mestre
57

Análise tomográfica, histológica, histométrica e imunoistoquímica do beta tricálcio fosfato com osso autógeno em aumento do soalho de seio maxilar /

Pereira, Rodrigo dos Santos. January 2014 (has links)
Orientador: Eduardo Hochuli Vieira / Banca: Roberta Okamoto / Banca: Nicolas Homsi / Resumo: A proposta deste estudo é avaliar o comportamento do enxerto ósseo composto de beta tricálcio fosfato (B-TCP) misturado ao osso autógeno na proporção de 1:1 frente a reabsorção, neoformação óssea e atividade molecular na enxertia do seio maxilar de humanos. Nove seios maxilares foram enxertados com esse material (Grupo Teste) e 12 com osso autógeno (Grupo Controle). Após 7 a 15 dias, os pacientes foram submetidos a uma tomografia computadorizada (TC) cone bean para mensurar o volume inicial do enxerto (T1). Decorrido 6 meses de reparação óssea, uma nova TC foi realizada para avaliar o volume final (T2) e verificar as alterações volumétricas dos materiais. Após 6 meses, no momento da instalação dos implantes dentais, biópsias foram colhidas por meio de uma broca trefina para avaliação histomorfométrica e imunoistoquímica. As taxas de reabsorção encontradas não foram significantes (p=0.17) com médias em torno de 38.3% ± 16.6 para o grupo teste e 45.7% ± 18.6 no grupo controle. Houve significância estatística na taxa de neoformação óssea do grupo teste (25.4% ± 6.4) em comparação com o grupo controle (38.6% ± 10.5). A análise imunoistoquímica teve como objetivo avaliar as proteínas Runx2, VEGF, TRAP e Osteocalcina. Os resultados encontrados com a imunomarcação destas, mostram que este enxerto possui um alto turnover celular e um tecido conjuntivo apresentando células em um curso de diferenciação celular. Visto isso, o enxerto do B-TCP misturado ao osso autógeno 1:1 em seio maxilar apresenta características moleculares com capacidade osteogênica promissora / Abstract: The aim of this study is to evaluate the behavior of beta tricalcium phosphate (B-TCP) mixed with autogenous bone compost graft in the rate 1:1 analyzing bone reabsorption, bone formation and molecular activity in grafting human maxillary sinus floor augmentation. Nine maxillary sinus were grafted with this material (Test group) and 12 with autogenous bone graft alone (Control Group). After 7 - 15 days, patients were submitted to an initial computed tomography (CT) to measure the initial graft volume (T1). After 6 months of bone healing, new CT was performed by patients to evaluate bone graft final volume (T2) and the graft volumetric changes. During dental implants placement, biopsies were collected with a 3.0 mm trephine burr and processed to histomorphometric and immunohistochemistry analisys. The average of reabsorption rates of test group were 38.3% ± 16.6 and 45.7% ± 18.6 to control group (p=0.17). The new bone formation was statistical significant between test group (25.4% ± 6.4) and control group (38.6% ± 10.5) (p<0.05). The immunohistochemistry analysis evaluated Runx2, VEGF, TRAP and Osteocalcin proteins. Outcomes showed a high cellular turnover with a pathway cellular differentiation in connective tissue. Thus, B-TCP mixed with autogenous bone graft in maxillary sinus presents propitious molecular characteristics to osteogenic capacity / Mestre
58

Contribuição ao estudo da osteoartrite secundária da articulação temporomandibular : estudo clínico - radiográfico retrospectivo em pacientes e modelo experimental em suínos /

Murayama, Rafael Akira. January 2003 (has links)
Orientador: Norberto Perri de Moraes / Mestre
59

Influência do desing, tratamento de superfície e densidade do substrato na estabilidade primária de implantes odontológicos. Análise por meio de torque de inserção, resistência ao arrancamento e freqüência de ressonância / Influence of the desing, surface treatment and substrate density on the primary stability of dental implants. Analysis using insertion torque, pull-out strength and resonance frequency.

Nathalia Ferraz Oliscovicz 14 December 2011 (has links)
A grande variedade de modelos de implantes disponíveis no mercado, assim como a variabilidade óssea nos pacientes, torna cada vez mais difícil a seleção do implante que permita obter uma maior estabilidade primária, fator essencial para osseointegração. O objetivo desse trabalho foi avaliar a influência do formato e tratamento de superfície de implantes, assim como do substrato utilizado, na estabilidade primária; aferida por meio de ensaios de desempenho e freqüência de ressonância. Foram utilizados 32 implantes Conexão®: 8 implantes cilíndricos hexágono externo sem tratamento de superfície (MS), 8 cilíndricos hexágono externo com tratamento Porous duplo (MP), 8 cilíndricos hexágono interno com tratamento Porous (CA), 8 cônicos sem tratamento (CC); todos com 11,5 mm de comprimento, e 3,75 mm de diâmetro para cilíndricos e 3,5 mm para os cônicos. Foram inseridos em diferentes substratos: osso de costela suína; osso artificial de poliuretana Synbone©; poliuretana Nacional® em três densidades - 15, 20 e 40 PCF; e madeira pinus. Para o ensaio de desempenho foi quantificado o torque de inserção com o torquímetro digital Mackena®, e a força de arrancamento por meio de força axial de tração com célula de carga de 200 kg, realizada na Máquina Universal de Ensaios Emic® DL-10000, e Software Tesc 3.13. A análise da freqüência de ressonância foi realizada com o aparelho Osstell Mentor®. Para obtenção dos resultados estes receberam tratamento estatístico ANOVA e Teste de Tukey com nível de significância a 5%. Ao analisar o torque de inserção, implantes com tratamento de superfície não foram diferentes estatisticamente do usinados, assim como os implantes cilíndricos não tiveram diferença estatística com os cônicos em todos os substratos (P>0,05), com exceção da poliuretana Synbone©, onde os cônicos apresentaram a menor média (4.45 ± 0.82) e tiveram diferença estatistica com os cilíndricos, hexágono externo (MP= 11.39 ± 0.76; MS= 10.34 ± 1.68), e interno (12.18 ± 3.78). No osso suíno, na poliuretana Nacional® de 15 PCF e na madeira, os implantes cônicos mostraram um melhor desempenho que nos outros substratos. Da mesma forma que no torque de inserção, em relação à força máxima de arrancamento, implantes tratados e usinados, assim como cônicos e cilíndricos, não tiveram diferença estatística (P>0,05), em todos os substratos; implantes cônicos só não apresentaram menores médias de força de arrancamento em matérias menos densos - osso suíno (138.19 ± 57.41 N), poliueretana Nacional® de 15 (209.57 ± 9.60 N) e 20 PCF(206.57 ± 31.51 N); e implantes cilindricos hexágono interno mostraram a maior média numérica em todos os materiais de inserção. Os valores de freqüência de ressonância mostraram que, apesar dos implantes com tratamento de superfície apresentarem maior média de ISQ que os implantes usinados em todos os substratos, estes não apresentaram diferença estatística entre si (P>0,05), com exceção da inserção na poliuretana Nacional de 20 PCF. Pôde-se concluir que, tanto o formato, como o tratamento de superfície dos implantes não influenciaram nas análises realizadas, entretanto, o substrato utilizado e sua densidade tiveram uma maior influência nos resultados obtidos. / The great variety of implant models available in the market, as well as the variability of patients bones, makes the selection of the implant that allows greatest primary stability, an essential factor for osseointegration, increasingly difficult. The aim of this study was to evaluate the influence of the format and surface treatment of implants, as well as the substrate used in primary stability; verified through resonance frequency and performance tests. 32 Conexão® implants were used: 8 cylindrical external hexagon implants without surface treatment (MS), 8 cylindrical external hexagon implants with double Porous treatment (MP), 8 cylindrical internal hexagon implants with Porous treatment (CA), and 8 tapered implants without treatment (CC). All had a length of 11.5 mm, while the cylindrical ones had a of diameter 3.75 mm compared with 3.5 mm for the tapered ones. They were inserted in different substrates: pig rib bone; artificial bone made from polyurethane Synbone©; Nacional® polyurethane in three densities - 15, 20 and 40 PCF; and pinus wood. For the performance test the insertion torque (N.cm) was quantified using the digital Mackena® torque meter, and the pull-out force (N) by means of axial traction force with a 200 kg load cell, carried out in the Emic® DL-10000 Universal Test Machine and the Tesc 3.13 software. The analysis of the resonance frequency (ISQ) was carried out with the Osstell Mentor® device. To obtain the results the ANOVA and Tukey statistical tests were used with a level of significance 5%. When analyzing the insertion torque, implants with surface treatment were not statistically different from the machined ones, nor did the cylindrical implants have any statistical difference from the tapered ones in all the substrates (P> 0.05), with exception of polyurethane Synbone©, where the tapered ones had a lower average (4.45 ± 0.82) and a statistical difference from the external hexagon (MP= 11.39 ± 0.76; 10.34 MS= ± 1.68), and internal hexagon (12.18 ± 3.78) cylindrical ones. In the pig bone, the 15 PCF Nacional® polyurethane and the wood tapered implants had a better performance that in the other substrate. Similar to the insertion torque, treated and machined implants, and tapered and cylindrical, did not have any statistical difference (P>0.05) in all the substrates; tapered implants only did not have a lower average of pull-out except in less dense substrates pig bone (138.19 ± 57.41 N), 15 Nacional® polyurethane (209.57 ± 9.60 N) and 20 PCF (206.57 ± 31.51 N). Internal cylindrical hexagon implants had the highest numerical average of all the inserted materials. The resonance frequency values showed that although the implants with surface treatment had a greater average ISQ that the machined implants in all the substrates, there was no statistical difference between them (P> 0.05), with the exception of the insertion of 20 PCF Nacional® polyurethane. It can be concluded that both the format and surface treatment of implants did not influence the analyses, however, the substrate used and their densities had a bigger influence on the results obtained.
60

Avaliação pré-clínica dos efeitos do osso bovino desproteinizado revestido com estrôncio sobre o reparo ósseo /

Tinajero Aroni, Mauricio Andres. January 2019 (has links)
Orientador: Rosemary Adriana Chiérici Marcantonio / Resumo: O objetivo deste estudo foi avaliar o efeito do uso de diferentes substitutos sobre o reparo ósseo de defeitos críticos de calvárias de ratos com ou sem osteoporose. Para tanto, foram divididos em três estudos. O estudo 1 avaliou o efeito de diferentes biomateriais sobre o reparo de defeitos críticos de calota (DCC) de 40 ratos saudáveis que foram aleatoriamente divididos em 5 grupos com 8 animais, de acordo com o tipo de biomaterial utilizado para preencher os DCC: Grupo COA (coágulo); Grupo AUT (osso autógeno); Grupo OBD (osso bovino desproteinizado); Grupo HA/ TCP (cerâmica bifásica composta de hidroxiapatita e β-fosfato tricálcio); Grupo TCP (β-fosfato tricálcio). Foram executadas análise microtomográfica para avaliação do comprimento linear remanescente (DLL) do DCC e o volume dos tecidos mineralizados (MT) dentro do defeito nos períodos de 3, 7, 15 e 30 dias após cirurgia. Adicionalmente, foi executado análise histométrica para avaliar a composição do tecido ósseo reparado (% Osso e % Biomaterial) no período de 30 dias. O grupo COA apresentou o menor DLL e MT dentro do DCC e maior % osso do que os outros grupos. O grupo OBD apresentou maior volume de tecidos mineralizados e maior % biomaterial do que o grupo os grupos AUT e TCP. Os grupos OBD e AUT apresentaram maior % osso que o grupo TCP. O estudo 2 avaliou o efeito do enxerto com OBD carregado de estrôncio (Sr) na cicatrização óssea em DCC em 42 ratos saudáveis. Foram feitos 2 defeitos/rato, e um destes aleatoriament... (Resumo completo, clicar acesso eletrônico abaixo) / Doutor

Page generated in 0.0722 seconds