• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 58
  • 19
  • Tagged with
  • 78
  • 78
  • 57
  • 52
  • 30
  • 20
  • 20
  • 17
  • 16
  • 16
  • 15
  • 15
  • 13
  • 12
  • 10
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

A retrospective study of the treatment of grade II furcations with a tricomponent bioresorbable membrane

Heinze, Joseph John. January 2006 (has links) (PDF)
Thesis--University of Oklahoma. / Bibliography: leaves 63-70.
42

Laser de baixa intensidade (670nm) na viabilidade do retalho cutâneo randômico em ratos / Low level laser therapy (670nm) on the viability of random skin flap in rats

Paulo Sérgio Bossini 28 February 2007 (has links)
Os retalhos cutâneos são amplamente utilizados na cirurgia plástica, principalmente na reparadora. Após o procedimento operatório, uma das principais complicações é a isquemia, podendo ocasionar a necrose do retalho. Vários recursos têm sido estudados com o intuito de aumentar a viabilidade desses retalhos. Dentre esses recursos, o laser de baixa intensidade é uma alternativa de tratamento, uma vez que pode promover um aumento da microcirculação e da neoformação vascular. Entretanto, existem discrepâncias na literatura em relação aos parâmetros empregados no uso do laser de baixa intensidade, principalmente das fluências utilizadas nos tratamentos. Este estudo teve como objetivo verificar o efeito de diferentes fluências do laser de 670nm, na viabilidade do retalho cutâneo randômico em ratos. Foram utilizados 100 ratos, da linhagem Wistar, distribuídos em 5 grupos de 20 animais cada. O retalho cutâneo randômico de base cranial foi realizado com dimensões de 10 X 4 cm e uma barreira plástica foi interposta entre o mesmo e o leito doador. O grupo 1 (controle) foi submetido à simulação de tratamento com o aparelho desligado. O grupo 2 foi submetido à radiação laser com fluência de 3 J/\'CM POT.2\'. Os grupos 3, 4 e 5 foram irradiados com fluências de 6 J/\'CM POT.2\', 12 J/\'CM POT.2\' e 24 J/\'CM POT.2\', respectivamente. Todos os grupos experimentais receberam a radiação laser imediatamente após o procedimento operatório e nos 4 dias subseqüentes, utilizando-se a técnica pontual em contato em 24 pontos distribuídos sobre e ao redor do retalho. No sétimo dia pós-operatório, as porcentagens da área de necrose dos retalhos foram avaliadas pelo método do gabarito de papel e também foi coletada uma amostra do retalho de 10 animais de cada grupo, escolhidos aleatoriamente, para a realização da contagem dos vasos sangüíneos. O grupo 1 apresentou média de área de necrose de 49,92%; o grupo 2 - 41,84%; o grupo 3 - 36,51%; o grupo 4 - 29,45% e o grupo 5 - 20,37%. Na contagem dos vasos, o grupo 1 obteve média de 65,2; o grupo 2 - 92,6; o grupo 3 - 105,5; o grupo 4 - 128,7 e o grupo 5 - 171,0. Na análise estatística, realizou-se a ANOVA, seguida do teste de comparações múltiplas de Tukey. Os resultados mostraram que todos os grupos experimentais apresentaram valores estatisticamente significativos comparados ao grupo controle, sendo que o grupo 5 apresentou a menor área de necrose e o maior número de vasos quando comparado aos demais grupos deste estudo (p < 0,01). O teste de correlação linear de Pearson indicou alta correlação negativa entre a porcentagem de necrose e o número de vasos dos retalhos (-0,972 / p = 0,0001). O laser de baixa intensidade (670nm) aplicado com fluência de 24 J/\'CM POT.2\' foi mais eficaz no aumento da viabilidade do retalho cutâneo randômico em ratos, comparado às outras fluências utilizadas neste estudo. / Skin flaps are widely used in plastic surgery, mainly in repair surgeries. After this reconstructive procedure, one of the main consequences is the decrease of blood flow in the area, which can be responsible by tissue necrosis. In this context, a lot of studies have investigated treatments able to increase the viability of the flap and the low level laser therapy (LLLT) has been chosen as an efficient treatment to reduce post-injury inflammatory processes and to stimulate the formation of new blood vessels. However, the use of a wide range of fluences by different authors and the lack of standardized experimental conditions make it difficult to compare published results. The aim of this study was to investigate the dose-response effects of 670nm laser on the viability of random skin flap in rats. One hundred Wistar male rats were used in this study. The animals were divided into 5 groups: group 1 (control group); group 2 (treated with 3 J/\'CM POT.2\'); group 3 (treated with 6 J/\'CM POT.2\'); group 4 (treated with 12 J/\'CM POT.2\') and group 5 (treated with 24 J/\'CM POT.2\'). The skin flap was made on the back of all animals studied (dimensions: 10 x 4 cm) and before the sutures were done, a plastic sheet was interposed between the flap and the donor site. Laser irradiation was performed immediately after the surgery and on days 1, 2, 3 and 4 post-surgery. The irradiation was made punctually, on 24 points on the skin surface and around it. The percentage of the necrosis area of the flap was calculated by the paper template method at the day 7 postoperative. Moreover, a sample of the skin flaps was collected from 10 rats of each group, which were chosen aleatory, to performe the count of the blood vessels. The animals of all treated groups showed statistically significant differences when compared to the control group (necrosis area: 49, 92%). The necrosis area of the treated groups were 41,82% (group 2), 36,51% (group 3), 29,45% (group 4) and 20,37% (group 5). In the count of blood vessels, group 1 showed the mean of 65,2; group 2 - 92,6; group 3 - 105,5; group 4 - 128,7 and group 5 - 171,0. The ANOVA test, followed by the Tukey test, for multiple comparasions were used. The results showed that all experimental groups showed statistically lower values for the necrosis area compared to the control and a higher number of blood vessels in the skin flap. It can be observed that the best results were found in the animals of group 5 (p < 0,01). In addition, the Pearson coefficient showed a significant negative correlation between necrosis area and the number of vessels (-0,972 / p = 0,0001). This present study has demonstrated that the 670nm laser was efficient to increase the viability of the skin flap, at all fluences used, with a tendency of reaching better results at higher dosages (24 J/\'CM POT.2\').
43

Estudo crítico da anatomia arterial do retalho vascularizado pela artéria perfurante muscular da artéria epigástrica inferior / Viability of utilizing the pectoralis major perforator muscular vessels as a recipient pedicle in immediate and late breast reconstruction with microsurgery

Alexandre Mendonça Munhoz 19 July 2004 (has links)
A utilização dos retalhos músculo-cutâneos na cirurgia plástica possibilitou grande avanço nas técnicas de reconstrução. Apesar de atualmente se apresentarem como técnica conhecida e reprodutível, existem ainda limitações quanto à morbidade na área doadora advinda da ressecção muscular. O desenvolvimento dos retalhos perfurantes e a aplicação clínica do retalho vascularizado na artéria perfurante muscular da artéria epigástrica inferior (DIEP) possibilitaram nova opção terapêutica em decorrência da completa preservação músculo-aponeurótica. Apesar dos benefícios funcionais em relação aos tradicionais retalhos músculo-cutâneos, o retalho DIEP exibe limitações como o tempo cirúrgico prolongado, a dificuldade técnica e o risco de lesão da artéria perfurante no trajeto intramuscular, todos decorrentes do calibre reduzido das artérias e da variabilidade anatômica. Embora a anatomia do músculo reto do abdome tenha sido exaustivamente estudada, escassas e imprecisas são as informações sobre a distribuição das artérias perfurantes, o trajeto intramuscular e as características do pedículo arterial. No presente estudo, a distribuição, o trajeto intramuscular e as dimensões do pedículo do retalho DIEP foram estudados em 15 cadáveres frescos não formolizados (30 retalhos) por técnica de coloração com tinta azul látex e posterior dissecção. Constatou-se 6,3 artérias perfurantes por retalho, sendo que a maior parte das artérias de médio e grande calibre localizavam-se na região lateral do músculo reto do abdome. Na análise do trajeto intramuscular foram classificadas de artérias com trajeto retilíneo, aquelas localizadas exclusivamente no septo muscular e sua dissecção foi realizada sem secção das fibras musculares. No trajeto oblíquo, se evidenciou mais de um septo muscular e houve a necessidade de se realizar a secção muscular. As artérias perfurantes da região lateral apresentaram trajeto retilíneo em maior número quando comparadas às artérias da região medial do músculo reto do abdome. Na maioria das dissecções, a artéria epigástrica inferior mostrou dois ramos principais sendo o calibre do ramo lateral maior ao do ramo medial. A maioria das artérias perfurantes de médio e grande calibres apresentaram origem no ramo lateral dominante da artéria epigástrica inferior. As artérias perfurantes e o pedículo arterial do retalho revelaram comprimento médio de 5,3 e 15,7 cm respectivamente. O pedículo arterial com a artéria perfurante proveniente da região medial apresentou comprimento maior do que o pedículo que continha a artéria proveniente da região lateral. O presente estudo permitiu-nos concluir que a maior concentração de artérias perfurantes de maior calibre e a presença do trajeto retilíneo na região lateral do músculo reto do abdome, constituíram parâmetros anatômicos importantes no planejamento da técnica. As conclusões obtidas reforçam a relevância dos estudos anatômicos na programação da reconstrução com retalhos vascularizados por artérias perfurantes. / The introduction of musculocutaneous flaps in plastic surgery has resulted in a great step forward in reconstructive procedures. In spite of their well-known and reproducible technique, their use is limited by morbidity in the donor area resulting from muscle resection. The development of perforator flap and the clinical application of the deep inferior epigastric flap (DIEP) has provided a new therapeutic option resulting from complete muscle-aponeurotic preservation. Despite the functional benefits achieved in comparison to traditional musculocutaneous flaps, the DIEP flap has limitations. The latter include prolonged operative time, technical difficulty and the risk of injury to the perforating artery in the intramuscular pathway. These factors result from reduced diameter of the arteries and to anatomic variation. Although anatomy of the rectus abdominus muscle has already been studied, information regarding distribution of the perforator arteries, intramuscular pathway, and characteristics of the arterial pedicle is lacking and inaccurate. In this thesis, the distribution, intramuscular pathway and pedicle size of the DIEP flap were studied in 15 fresh cadavers. Thirty flaps were analyzed by staining with blue latex dye and subsequent dissection. An average of 6.3 perforator arteries per flap were observed, and the major concentration of medium and large diameter arteries in the lateral region of the rectus muscle. The intramuscular pathway analysis classified the arteries as rectilinear, those located solely in the muscle septum and their dissection was performed without muscle fibers section. In the oblique pathway, not a single septum was observed and muscle section was necessary. A larger number of the perforator arteries of the lateral region presented a rectilinear path compared to the arteries of the medial region. In the majority of dissections, the inferior epigastric artery exhibited two main branches with the lateral branch diameter greater than that of the medial branch. The majority of the perforator arteries of medium and large diameter originated in the dominant lateral branch of the IEA. The perforator arteries and the arterial pedicle of the flap displayed a mean length of 5.3 and 15.7cm respectively. The arterial pedicle presenting the perforator artery originating from the medial region was longer than the pedicle containing the artery originating from the lateral region. The major concentration of perforator arteries of larger diameter besides being rectilinear in the lateral region of the rectus muscle establishes important parameters for technical planning. The results obtained in this study emphasize the importance of the anatomic studies in planning reconstructions with perforator flaps.
44

Estudo da ação da estreptoquinase e do alopurinol em retalhos cutâneos em ilha submetidos à isquemia prolongada: estudo experimental em ratos / Study of the effect of streptokinase and alopurinol in island skin flaps submitted to prolonged ischemia - experimental study in rats

Tatiana de Moura 21 September 2009 (has links)
Objetivo: Estabelecer relação entre a sobrevivência de retalhos cutâneos em ilha submetidos à isquemia prolongada e o uso da estreptoquinase e do alopurinol administrados após o período de isquemia prolongado. Método: Foram utilizados 48 ratos machos da raça Wistar, com pesos entre 300 e 350g, divididos em quatro grupos com 12 cada um, sendo; grupo controle, alopurinol, estreptoquinase e associação de alopurinol com estreptoquinase, submetidos à dissecção de retalho epigástrico em ilha, seguido de clampeamento do feixe vascular, por 8 horas em isquemia mista normotérmica. Após este período, as pinças foram retiradas e cada animal recebeu o esquema terapêutico proposto através de injeção intravenosa. A análise da sobrevivência dos retalhos foi realizada no sétimo dia de pós-operatório. Foram realizadas análises descritivas (% de área necrótica) e de variâncias, bem como, comparações múltiplas de Dunnett T3 entre os quatro grupos e o teste da mediana. Resultados: O grupo controle apresentou em média 79,88% de necrose da área total, aqueles que receberam alopurinol apresentaram em média 64,05% de necrose e o grupo que recebeu estreptoquinase apresentou em média 55,52% de necrose. Com a associação das duas drogas os ratos apresentaram em média 54,30% de área necrótica. Aplicando o teste Dunnett e o teste da mediana verificouse de que o grupo estreptoquinase é o que possui o menor percentual de necrose neste estudo, e o que apresentou diferença estatística significativa em relação ao grupo controle. Conclusão: A administração sistêmica da estreptoquinase após 8 horas de isquemia mista normotérmica resultou em aumento da sobrevivência de retalhos epigástricos em ilha em ratos, quando comparado à administração de alopurinol, associação do alopurinol e estreptoquinase e do grupo controle / Background: To establish a relation between the survival rate of island skin flaps submitted to a prolonged ischemia and the effect of streptokinase and allopurinol administered after the ischemic period. Methods: A total of 48 male Winstar rats, each weighing between 300 and 350 grams, separated in four groups of twelve each, as follows: control, alopurinol, streptokinase and association of allopurinol and streptokinase, were submitted to an epigastric island flap dissection followed by the epigastric vessel bundle clamping. Flaps remained this way for 8 hours in normothermic mixed ischemia. After the ischemic period, the clamps were removed and each rat received the therapeutical scheme proposed for the group through intravenous injections. Flap survival analysis was performed on the seventh post operative day. Variance and descriptive analyses (as a percentage of the necrotic area) as well as Dunnett-T3 multiple comparisons among the 4 groups and median tests were carried out. Results: Rats in the control group presented an average of 79.88% of necrosis in the flap total area; those which received allopurinol presented an average of 64.05% of necrosis whereas the group which received streptokinase showed an average of 55.52% of necrosis. With the association of both drugs, rats presented an average of 54.30% of necrosis in the flap total area. . By applying Dunnet test and the median test, we could verify that the streptokinase group had the lowest necrosis rate in this study. Conclusion: The systemic administration of streptokinase after 8 hours of normothermic global ischemia resulted in an increase in survival rate of epigastric island skin flaps in rats, when compared to the administration of alopurinol, association of the two drugs and the control group
45

Retalho miocutâneo de peitoral maior na reconstrução dos defeitos da cabeça e pescoço: estudo anatômico / Pectoralis major myocutaneous pedicled flap for head and neck defects reconstruction: anatomic study

Christiana Maria Ribeiro Salles Vanni 16 October 2013 (has links)
Objetivos: Avaliar se o comprimento do pedículo do retalho miocutâneo de peitoral maior assim como seu alcance para diversos sítios da região cervicofacial são influenciados por dados antropométricos e pelo lado de dissecção do retalho. O trabalho busca também determinar se a rotação infraclavicular proporciona ganho significativo quanto ao alcance do retalho em comparação à rotação supraclavicular. Delineamento: Estudo prospectivo anatômico em cadáveres e em pacientes tipo transversal. Materiais: Foram estudados 50 retalhos miocutâneos de peitoral maior em 25 cadáveres adultos não formolizados com menos de 24 horas de óbito fornecidos pelo Serviço de Verificação de Óbitos da Universidade de São Paulo e, a seguir, 15 pacientes submetidos à reconstrução de defeitos cervicofaciais com este retalho. Métodos: Padronizou-se em todos os casos estudados uma ilha de pele quadrangular, medindo 8x6 cm (altura x largura) localizada sobre a porção esternocostal do músculo peitoral maior, medialmente ao mamilo e tendo como limite caudal a borda superior da sétima costela. Todos os retalhos foram baseados apenas no ramo peitoral da artéria toracoacromial e a rotação foi realizada inicialmente sobre a clavícula. O comprimento do pedículo foi medido após a rotação, do ponto médio clavicular até o nível da borda superior da ilha de pele. Testou-se o alcance do centro da ilha de pele do retalho para as seguintes regiões: proeminência laríngea da cartilagem tireoide, mento, ângulo da mandíbula, conduto auditivo externo e órbita. Analisou-se a relação do comprimento do pedículo e do alcance do retalho com dados antropométricos e com o lado de dissecção. Posteriormente, realizou-se a rotação do retalho por baixo da clavícula apenas nos cadáveres e testou-se novamente seu alcance para as mesmas regiões, comparando com os resultados da rotação supraclavicular. Resultados: Nos cadáveres, o comprimento do pedículo apresentou um valor médio de 17,67 ± 2,24 cm, já para os pacientes, encontramos uma média de 16,03 ± 1,35 cm. Todos os retalhos obtiveram alcance para todas as regiões estudadas, com exceção da órbita, que foi alcançada nos cadáveres em 20 casos por rotação supraclavicular (40%) e 21 casos por rotação infraclavicular (42%). Nos pacientes, a óbita foi alcançada em 13,3% dos casos. Nos cadáveres, a rotação infraclavicular não apresentou ganho significativo para o alcance à órbita (p=0,839 - qui-quadrado) nem para as outras regiões estudadas, embora tenha havido um ganho de 0,61 cm na média do comprimento do pedículo, dado com significância estatística (p=0,01; pela Correlação de Person). Considerando os cadáveres, na análise univariada, foi observado que houve diferença estatisticamente significativa para o alcance do retalho à órbita em indivíduos com maior distância acrômiotrocantérica - DAT (p= 0,008 - teste \"t\" de Student), maior distância biacromial - DBA (p= 0,024 - teste \"t\" de Student) e menor valor da razão entre a distância mastoide-fúrcula esternal pela distância acrômio-trocantérica - DMF/DAT (p= 0,005 - teste \"t\" de Student). Também se observou que os cadáveres cujos retalhos alcançaram a órbita, apresentavam peso estatisticamente superior (p=0,036 - teste \"t\" de Student). Em relação ao comprimento do pedículo, na análise univariada, houve correlação positiva e estatisticamente significativo entre o comprimento do pedículo e a distância biacromial - DBA (r= 0,311; p= 0,028 - correlação de Pearson); correlação negativa e também significativo com a razão entre a distância mastoide-fúrcula esternal pela distância biacromial - DMF/DBA (r= -0,362; p= 0,010 - correlação de Pearson) e com a razão entre a distância mastoide-fúrcula esternal pela distância acrômio-trocantérica - DMF/DAT (r= -0,403; p= 0,004 - correlação de Pearson). Já nos pacientes, a análise univariada mostrou correlação positiva e estatisticamente significativo entre o comprimento do pedículo e o comprimento do esterno - CE (r= 0,722; p= 0,002 - correlação de Sperman) e correlação negativa e também significativo com a razão entre a distância mastoide-fúrcula esternal pelo comprimento do esterno - DMF/CE (r= -0,587; p= 0,021 - correlação de Sperman). Com os resultados obtidos nesta última análise, as variáveis nos pacientes com p < 0,20 foram submetidas à análise multivariada por modelo de regressão linear, visando estabelecer as variáveis que podem determinar o comprimento do pedículo vascular do retalho. Desta forma, identificou-se o comprimento do esterno como a única variável capaz de determinar o comprimento do pedículo vascular do RMPM (p=0,004). Com base nestes dados de regressão, foi então estabelecida uma equação capaz de determinar o comprimento do pedículo vascular do RMPM (COMP) baseada no comprimento do esterno, como demonstrada a seguir: COMP = 2,54 + 0,64 X CE. Conclusões: A rotação infraclavicular do retalho miocutâneo de peitoral maior não proporciona ganho no alcance do retalho em relação à região cervicofacial em comparação à rotação supraclavicular; o alcance do retalho miocutâneo peitoral maior não é influenciado pelo lado de dissecção e por dados antropométricos; o comprimento do pedículo vascular não é influenciado pelo lado de dissecção, mas sofre influência positiva do comprimento esternal. Apesar do alcance do retalho não sofrer influência de dados antropométricos, por este modelo anatômico infere-se que a equação determinante do comprimento do pedículo pode, na prática clínica, contribuir para o planejamento de reconstruções utilizando o retalho miocutâneo de peitoral maior, sobretudo para defeitos mais craniais / Objectives: Determine whether the length of the pectoralis major myocutaneous pedicled flap and its ability to reach multiple head and neck sites are influenced by anthropometric data and by the side of flap dissection. The study is also designed to determine whether infraclavicular rotation provides a significant gain in flap reach over supraclavicular rotation. Design: Prospective, cross-sectional and anatomical study on cadavers and patients. Materials: Fifty pectoral major myocutaneous flaps were studied in fresh adult cadavers less than 24 hours after death provided by the Serviço de Verificação de Óbitos of the University of São Paulo, and later in 15 patients undergoing head and neck reconstruction using this flap. Methods: For all cases a standardized quadrangular skin island measuring 8 cm x 6 cm (height x width) was employed, located over the sternocostal portion of the major pectoralis muscle, with the nipple as the medial limit and the muscle\'s inferior border as the caudal limit. All flaps were based only on the pectoralis branch of the thoracoacromial artery and the rotation was initially performed over the clavicle. Pedicle length was measured after rotation, from the midpoint of the clavicle to the superior border of the skin island. The reach of the skin island center was tested to the following sites: laryngeal prominence of the thyroid cartilage, chin, angle of the mandibule, external auditive canal and orbit. Ratios of the length of the pedicle and the reach of the flap and the anthropometric data and dissection side were analyzed. Afterwards, only in the cadavers, the flap was rotated beneath the clavicle and its reach to the same regions was measured again, and then compared to the result obtained from supraclavicular rotation. Results: In the cadavers, the average pedicule flap length was 17.67 ± 2.24 cm, while for the patients, the average length was 16.03 ± 1.35 cm. All flaps reached all studied sites, except for the orbit, which was reached in 20 cases by supraclavicular rotation (40%), and in 21 cases beneath the clavicle (42%) in the cadavers, and in 13.3% of the patients. In the cadavers, infraclavicular rotation did not result in a significant gain in reach to the orbit or to any other studied site (P=0.839 - chi-square), although there was a statistically significant (p=001; Pearson Correlation) gain of 0.61 cm in the average length of the flap. In the univariate analysis, there was a statistically significant difference in the cadavers for the reach of the flap to the orbit in individuals with a greater acromion-trochanter distance (DAT; p= 0.008 - Student\'s t-test), greater biacromial distance (DBA; p= 0.024 - Student\'s t-test) and a smaller value for the ratio of the mastoidsuprasternal notch distance over the acromion-trochanter distance - DMF/DAT (p= 0.005 - Student\'s t-test). It was also observed that the cadavers whose flaps reached the orbit had statistically higher body weights (p=0.036 - Student\'s t-test). With regard to the length of the flap, in the univariate analysis, there was a positive and statistically significant correlation between the length of the flap and the biacromial distance - DBA (r= 0.311; p= 0.028 - Pearson correlation); a negative and statistically significant correlation with the ratio of the mastoid-suprasternal notch distance over the biacromial distance - DMF/DBA (r= -0.362; p= 0.010 - Pearson correlation) and with the ratio between the mastoid-suprasternal notch distance over the acromion-trochanter distance - DMF/DAT (r= -0.403; p= 0.004 - Pearson correlation). Whereas in the patients, the univariate analysis showed a positive and statistically significant correlation between the length of the flap and the length of the sternum (CE) (r= 0.722; p= 0.002 - Spearman correlation) and a negative and statistically significant correlation with the ratio between the mastoidsuprasternal notch distance over the length of the sternum - DMF/CE (r= - 0.587; p= 0.021 - Spearman correlation). With the results obtained in this last analysis, the variables in the patients with p < 0.20 were submitted to multivariate analysis using linear regression in an effort to establish an equation to predict the length of the vascular flap. Sternum length (p=0.004) was the only variable found that was capable of determining the length of the vascular pedicle of the PMMC flap. Based on these regression data, an equation was formulated to determine the length of the vascular pedicle of the PMMC flap (COMP) based on the length of the sternum (CE), as follows: COMP = 2.54 + 0.64 X CE. Conclusions: Infraclavicular rotation of the pectoral major myocutaneous flap does not add to the reach of the flap to the head and neck region as compared to supraclavicular rotation; the reach of the pectoral major myocutaneous flap is not influenced by the side of the dissection or by anthropometric measures; and the length of the vascular pedicle is not influenced by the side of dissection, but is positively influenced by sternum length. Although anthropometric measures do not influence the reach of the flap according to this anatomical model, it can be inferred that the determinant equation of the length of the pedicle can, in practice, contribute to the planning of head and neck reconstruction using the pectoral major myocutaneous flap, especially for more cranial defects
46

"Estudo anatômico do retalho perfurante ântero-lateral da coxa" / Anatomic study of the anterolateral thigh flap

Ishida, Luiz Carlos 17 August 2006 (has links)
INTRODUÇÃO: O retalho ântero-lateral da coxa é baseado em vasos perfurantes do ramo descendente da artéria circunflexa lateral femoral. Este retalho tem características muito interessantes para a cirurgia reparadora, como a pequena espessura, pedículo longo e excelente área doadora. No entanto, existem muitas controvérsias na literatura quanto aos vasos perfurantes e ao trajeto do pedículo deste retalho. Neste trabalho procurou-se estabelecer alguns parâmetros anatômicos e esclarecer estas controvérsias. MÉTODO: Estudaram-se 100 coxas de 50 cadáveres quanto aos seguintes aspectos: 1- Número e localização de perfurantes encontrados, 2- Trajeto do pedículo perfurante, 3- Trajetória intramuscular, 4- Comprimento do trajeto intramuscular, 5- Comprimento total do pedículo, 6- Diâmetro dos vasos e 7- Espessura do retalho. RESULTADOS: 1- Encontraram-se de 0 a 4 perfurantes por coxa estudada, todas em um raio de até 6cm do ponto médio entre a espinha ilíaca ântero-superior e a borda lateral da patela. 2- Os vasos perfurantes tinham trajeto músculo-cutâneo em 75,76% das coxas e septo-cutâneo em 24,24%. 3- Dos pedículos perfurantes com trajeto músculo-cutâneo, 86,67% possuíam trajetória indireta contra 13,33% com trajetória direta. 4- O comprimento médio do trajeto intramuscular dos pedículos foi de 3,67 ± 2,01 cm. 5- O comprimento médio do pedículo total foi de 11,31 ± 3,12 cm. 6- O diâmetro médio da artéria na origem do ramo descendente da artéria circunflexa femoral foi de 2,21 ± 0,85 mm e para as veias no mesmo local de 2,66 ± 1,33 mm e 2,10 ± 1,11 mm. 7- A espessura da tela subcutânea foi de 8,98 ±6,23 mm e da pele de 1,60 ± 0,76 mm. CONCLUSÕES: 1- Existiu uma pequena possibilidade de não haver pedículos perfurantes. 2- Quando presentes, os pedículos perfurantes do ramo descendente da artéria circunflexa lateral femoral eram encontrados em numero de 1 a 4, sempre em um raio de 6 cm a partir do ponto médio entre a espinha ilíaca ântero-superior e a borda lateral da patela. 3- Os trajetos dos pedículos perfurantes eram predominantemente músculo-cutâneos. 4- A trajetória intramuscular encontrada foi predominantemente indireta. 5- O comprimento do trajeto intramuscular correspondeu a 31,69% do comprimento total do pedículo. 6- O comprimento total do pedículo se mostrou adequado tanto para transferências locais como à distancia por técnicas microcirúrgicas. 7- Os diâmetros dos vasos, tanto da artéria quanto das veias, se mostraram adequados para a realização de anastomoses microcirúrgicas. 8- A espessura do retalho encontrada foi significantemente maior nas coxas de indivíduos femininos, mas tanto nos homens quanto nas mulheres a espessura foi relativamente fina. / INTRODUCTION: The anterolateral thigh flap is based on the perforator vessels of the descending branch of the lateral circumflex femoral artery. This flap has very interesting characteristics for the reconstructive surgery, like the small thickness, long pedicle and excellent donor site. On the other hand, there are many controversial data on the literature about the perforator vessels and the pedicle course of this flap. The aims of this study are to establish some anatomical parameters and clear some controversies. METHOD: A hundred thighs of 50 cadavers were studied for: 1- The number and location of the perforator vessels. 2- The course of the perforator pedicles. 3- The intramuscular course. 4- The length of the intramuscular course. 5- The total length of the vascular pedicle. 6- The diameter of the vessels. and 7- The thickness of the flap. RESULTS: 1- There were found from 0 to 4 perforators per thigh, all in a 6cm radius from the mid point between the anterosuperior iliac spine and the lateral border of the patella. 2- The pedicles was musculocutaneous in 75,76% of the thighs and septocutaneous in 24,24%. 3- Among the musculocutaneous pedicles, 86,67% had a direct intramuscular course, and 13,33% had indirect course. 4- The mean length of the intramuscular course was 3,67 ± 2,01 cm. 5- The mean total pedicle length was 11,31 ± 3,12 cm. 6-The mean artery diameter on the origin of the descending branch of the lateral circumflex femoral artery was 2,21 ± 0,85 mm and the mean vein diameter on the same spot was 2,66 ±1,33 mm and 2,10 ± 1,11 mm. 7- The mean subcutaneous fat tissue thickness was 8,98 ± 6,23 mm and the mean skin thickness was e 1,60 ± 0,76 mm. CONCLUSIONS: 1- There was a possibility of finding no perforators of the descending branch of the lateral circumflex femoral artery. 2- When present, the perforators pedicles were found in numbers between 1 to 4, always in a 6cm radius from the mid point between the anterosuperior iliac spine and the lateral border of the patella. 3- The perforators pedicles courses were predominantly musculocutaneous. 4- The intramuscular courses were mainly indirect. 5- The intramuscular length was responsible for 31,69% of the total length of the vascular pedicle. 6- The total length of the pedicle was adequate for either local or microsurgical transfers. 7- The arterial and venous diameters were adequate for microsurgical anastomosis. 8- The female cadavers had significantly thicker flaps, but both in the male and the female cadavers the flap was considerably thin.
47

"Estudo anatômico do retalho perfurante ântero-lateral da coxa" / Anatomic study of the anterolateral thigh flap

Luiz Carlos Ishida 17 August 2006 (has links)
INTRODUÇÃO: O retalho ântero-lateral da coxa é baseado em vasos perfurantes do ramo descendente da artéria circunflexa lateral femoral. Este retalho tem características muito interessantes para a cirurgia reparadora, como a pequena espessura, pedículo longo e excelente área doadora. No entanto, existem muitas controvérsias na literatura quanto aos vasos perfurantes e ao trajeto do pedículo deste retalho. Neste trabalho procurou-se estabelecer alguns parâmetros anatômicos e esclarecer estas controvérsias. MÉTODO: Estudaram-se 100 coxas de 50 cadáveres quanto aos seguintes aspectos: 1- Número e localização de perfurantes encontrados, 2- Trajeto do pedículo perfurante, 3- Trajetória intramuscular, 4- Comprimento do trajeto intramuscular, 5- Comprimento total do pedículo, 6- Diâmetro dos vasos e 7- Espessura do retalho. RESULTADOS: 1- Encontraram-se de 0 a 4 perfurantes por coxa estudada, todas em um raio de até 6cm do ponto médio entre a espinha ilíaca ântero-superior e a borda lateral da patela. 2- Os vasos perfurantes tinham trajeto músculo-cutâneo em 75,76% das coxas e septo-cutâneo em 24,24%. 3- Dos pedículos perfurantes com trajeto músculo-cutâneo, 86,67% possuíam trajetória indireta contra 13,33% com trajetória direta. 4- O comprimento médio do trajeto intramuscular dos pedículos foi de 3,67 ± 2,01 cm. 5- O comprimento médio do pedículo total foi de 11,31 ± 3,12 cm. 6- O diâmetro médio da artéria na origem do ramo descendente da artéria circunflexa femoral foi de 2,21 ± 0,85 mm e para as veias no mesmo local de 2,66 ± 1,33 mm e 2,10 ± 1,11 mm. 7- A espessura da tela subcutânea foi de 8,98 ±6,23 mm e da pele de 1,60 ± 0,76 mm. CONCLUSÕES: 1- Existiu uma pequena possibilidade de não haver pedículos perfurantes. 2- Quando presentes, os pedículos perfurantes do ramo descendente da artéria circunflexa lateral femoral eram encontrados em numero de 1 a 4, sempre em um raio de 6 cm a partir do ponto médio entre a espinha ilíaca ântero-superior e a borda lateral da patela. 3- Os trajetos dos pedículos perfurantes eram predominantemente músculo-cutâneos. 4- A trajetória intramuscular encontrada foi predominantemente indireta. 5- O comprimento do trajeto intramuscular correspondeu a 31,69% do comprimento total do pedículo. 6- O comprimento total do pedículo se mostrou adequado tanto para transferências locais como à distancia por técnicas microcirúrgicas. 7- Os diâmetros dos vasos, tanto da artéria quanto das veias, se mostraram adequados para a realização de anastomoses microcirúrgicas. 8- A espessura do retalho encontrada foi significantemente maior nas coxas de indivíduos femininos, mas tanto nos homens quanto nas mulheres a espessura foi relativamente fina. / INTRODUCTION: The anterolateral thigh flap is based on the perforator vessels of the descending branch of the lateral circumflex femoral artery. This flap has very interesting characteristics for the reconstructive surgery, like the small thickness, long pedicle and excellent donor site. On the other hand, there are many controversial data on the literature about the perforator vessels and the pedicle course of this flap. The aims of this study are to establish some anatomical parameters and clear some controversies. METHOD: A hundred thighs of 50 cadavers were studied for: 1- The number and location of the perforator vessels. 2- The course of the perforator pedicles. 3- The intramuscular course. 4- The length of the intramuscular course. 5- The total length of the vascular pedicle. 6- The diameter of the vessels. and 7- The thickness of the flap. RESULTS: 1- There were found from 0 to 4 perforators per thigh, all in a 6cm radius from the mid point between the anterosuperior iliac spine and the lateral border of the patella. 2- The pedicles was musculocutaneous in 75,76% of the thighs and septocutaneous in 24,24%. 3- Among the musculocutaneous pedicles, 86,67% had a direct intramuscular course, and 13,33% had indirect course. 4- The mean length of the intramuscular course was 3,67 ± 2,01 cm. 5- The mean total pedicle length was 11,31 ± 3,12 cm. 6-The mean artery diameter on the origin of the descending branch of the lateral circumflex femoral artery was 2,21 ± 0,85 mm and the mean vein diameter on the same spot was 2,66 ±1,33 mm and 2,10 ± 1,11 mm. 7- The mean subcutaneous fat tissue thickness was 8,98 ± 6,23 mm and the mean skin thickness was e 1,60 ± 0,76 mm. CONCLUSIONS: 1- There was a possibility of finding no perforators of the descending branch of the lateral circumflex femoral artery. 2- When present, the perforators pedicles were found in numbers between 1 to 4, always in a 6cm radius from the mid point between the anterosuperior iliac spine and the lateral border of the patella. 3- The perforators pedicles courses were predominantly musculocutaneous. 4- The intramuscular courses were mainly indirect. 5- The intramuscular length was responsible for 31,69% of the total length of the vascular pedicle. 6- The total length of the pedicle was adequate for either local or microsurgical transfers. 7- The arterial and venous diameters were adequate for microsurgical anastomosis. 8- The female cadavers had significantly thicker flaps, but both in the male and the female cadavers the flap was considerably thin.
48

Efeito da toxina botulínica tipo A na viabilidade do retalho cutâneo dorsal em ratos saudáveis, expostos à fumaça de cigarro e diabéticos / Effect of botulinum toxin type A on cutaneous flap viability in diabetic, tobacco-exposed, and healthy rats

Camargo, Cristina Pires 01 December 2014 (has links)
Introdução: Os autores estudaram o efeito da toxina botulinica tipo A (BontA) na viabilidade de retalhos cutâneos em ratos saudáveis, expostos à fumaça de cigarro e diabéticos. Material e métodos: Foram avaliados 90 ratos Wistar machos com peso variando entre 170 a 469 g (média 282,56 g). Esses animais foram divididos em seis grupos: saudáveis com aplicação de solução fisiológica (SF) (C1), saudáveis com aplicação de Toxina botulínica tipo A (BontA) (C2), expostos à fumaça de cigarro com aplicação de SF (T1), expostos à fumaça de cigarro com aplicação de BontA (T2), diabéticos com aplicação de SF (D1) e diabéticos com aplicação de BontA (D2). Os ratos pertencentes ao grupo exposição à fumaça de cigarro foram expostos por um período de 28 dias duas vezes ao dia ininterruptamente. O Diabete foi induzido pela injeção, intravenosa de estreptozotocina (55 mg/Kg) 56 dias antes do início dos procedimentos. Sete dias antes da realização do retalho cutâneo foi injetado ao longo do retalho, BontA (20u) ou SF 0,9%, de acordo com o subgrupo ao qual o animal foi alocado. Foi realizado procedimento para obtenção de retalho cutâneo dorsal (3x10 cm) e no sétimo pósoperatório os retalhos foram fotografados e a seguir realizada eutanásia. As fotografias foram digitalizadas e analisadas pelo programa Image J®, através do qual foi aferido área viável e área total. Através do programa Excel® foi calculado a razão da área viável/área total dos retalhos dorsais dos animais. A seguir foi coletado amostra de tecido com dimensões de 0,4x5 cm, para análise das arteríolas (lúmen, diâmetro, espessura média da parede arteriolar e razão do lúmen/espessura média), segundo método de estereologia. Resultados: A razão de área viável/área total apresentou diferença significativa no grupo controle tratado com BontA, (C2 x C1; 0,9 ± 0,1 vs 0,67 ± 0,15, p= 0,001). O mesmo comportamento foi observado no grupo diabete que recebeu a aplicação de BontA (D2 x D1 groups; 0,97±0,2 vs 0,61±0,24, p=0,018). O grupo exposto à fumaça de cigarro não apresentou diferença estatística. À estereologia, não houve diferença da avaliação miscrocópica dos grupos controle e expostos à fumaça de cigarro. O grupo diabete mostrou diferença estatística nos animais que receberam a aplicação de BontA em relação os que receberam SF, lúmen (p=0,004), diâmetro (p=0,05), razão lúmen/espessura média (p=0,003). Conclusão: a toxina botulínica tipo A aumentou a viabilidade do retalho cutâneo dorsal em ratos sadios e diabéticos no sétimo pós-operatório. Houve aumento do lúmen, diâmetro, razão do lúmen/ espessura média dos retalhos cutâneos dos animais diabéticos / Background: Botulinum toxin A (BoNTA) might be effective in reducing skin flap necrosis. This study investigated BoNTA influence on skin flap viability in healthy, tobacco-exposed and diabetic rats. Methods: Ninety male Wistar rats (170 a 469 g) were randomly divided into six groups: control+saline solution (C1), control+BoNTA (C2), tobacco-exposed+saline solution (T1), tobacco-exposed+BoNTA (T2) diabetes+saline solution (D1) and diabetes+BoNTA (D2). A dorsal random skin flap (3 × 10 cm) was performed on each rat. Total flap and necrosis areas were measured through macroscopic evaluation using ImageJ® software. Survival area /total area ratio was calculated. After euthanasia skin flap samples were collected for stereological assessment. Lumen, diameter, wall thickness, and lumen/wall thickness ratio of all arterioles along the panniculus carnosus were measured. Results: Survival flap area/total flap area ratio increased in control group with BoNTA injection compared with control animals injected with saline solution (C2 x C1 groups; 0.9 ± 0.1 vs 0.67 ± 0.15, p= 0.001). A similar result was found in the diabetic group injected with BontA when compared with the diabetic group injected with saline solution (D2 x D1 groups; 0.97±0.2 vs 0.61±0.24, p=0.018). We did not observe any difference in skin flap viability in the tobacco-exposed groups (T1 x T2 groups; 0.64± 0.21 vs 0.74±0.24, p=0.871)). Lumen(p=0.004), diameter(p=0.05) and lumen/wall thickness ratio (p=0.003) were increased in diabetic BoNTA-treated animals compared with diabetic animals injected with saline solution. This effect was not observed in control groups or in the tobacco-exposed groups. Conclusion: BoNTA increased skin flap viability in control and diabetic rats on the seventh postoperative day and resulted in increased lumen, diameter, and lumen/wall thickness ratio in the diabetic animals
49

Aplicação da cola de fibrina em microanastomoses vasculares: análise comparativa com a técnica de sutura convencional utilizando um modelo experimental de retalho microcirúrgico / Application of fibrin glue in microvascular anastomosis: comparative analysis with the conventional suture technique using an experimental free flap model

Cho, Alvaro Baik 17 March 2008 (has links)
INTRODUÇÃO: A microanastomose vascular é um componente importante na cirurgia de transferência livre de tecidos. Atualmente, a técnica de sutura convencional ainda é considerada o padrão ouro, no entanto, ela apresenta alguns inconvenientes por ser tecnicamente difícil, consumir muito tempo e ter uma longa curva de aprendizado. Na busca de uma técnica mais fácil e rápida, métodos alternativos de anastomose são estudados incluindo a cola de fibrina. Apesar dos bons resultados publicados, a sua aceitação na prática clínica ainda é limitada. Controvérsias a cerca de sua trombogenicidade e resistência mecânica geram dúvidas em relação a sua segurança. A ausência de um modelo experimental mais fidedigno impede que os potenciais benefícios de sua aplicação clínica sejam apreciados. O objetivo deste estudo é esclarecer essas controvérsias e estudar os benefícios da aplicação da cola de fibrina em um ambiente que simule a prática clínica. MÉTODOS: O modelo experimental utilizado foi a transferência livre de um retalho inguinal para a região cervical anterior. A circulação do retalho era restaurada através de microanastomoses vasculares entre as artérias femoral e carótida (término-lateral) e entre as veias femoral e jugular externa (término-terminal). Utilizamos 20 coelhos que foram divididos em dois grupos (n= 10) de acordo com a técnica de sutura empregada: Grupo I (sutura convencional) e Grupo II (sutura com cola). RESULTADOS: A aplicação da cola de fibrina reduziu significativamente o número de pontos necessários para se completar as anastomoses, 4 pontos a menos nas artérias e 4,5 pontos a menos nas veias. No Grupo I, a média do tempo de anastomose arterial foi de 17,21 minutos, contra 12,72 minutos no Grupo II. Nas anastomoses venosas, a média de tempo no Grupo I foi de 22,93 minutos, contra 16,57 minutos no Grupo II. A aplicação da cola de fibrina também diminuiu o tempo de isquemia do retalho e o tempo de cirurgia em 11,5 minutos e 15,67 minutos, respectivamente. A taxa de sobrevida do retalho foi de 90% nos dois grupos. CONCLUSÕES: A aplicação da cola de fibrina em microanastomoses vasculares demonstrou ser confiável e eficiente no presente estudo. / INTRODUCTION: Microvascular anastomosis is an important component of the free flap surgical procedure. Currently, the conventional suture is still considered the gold standard technique. However, it presents some problems for being technically demanding, time consuming and with a long learning curve. In looking for an easier and faster technique, alternative methods of anastomosis were studied including the fibrin glue. Despite the good results reported in the literature, its acceptance in the clinical setting is still small Controversies regarding its thrombogenicity and mechanical resistance create some concerns about its safeness. The absence of a more realistic experimental model has not allow a full aprecciation of its potencial benefits in clinical use. The aim of this study is clarify these controversies and demonstrate the advantages of fibrin glue application in an environment that can reproduce the clinical practice. METHODS: A free inguinal flap transfer to the anterior cervical region was used as experimental model. The circulation of the flap was restored by means of microvascular anastomosis between the femoral and carotid arteries (end-to-side) and between the femoral and jugular veins (end-to end). The procedures were performed in 20 rabbits that were divided into two groups (n= 10) according to the anastomosis technique: Group I (conventional) and Group II (fibrin glue). RESULTS: The application of fibrin glue significantly reduced the amount of sutures required to complete the anastomoses: 4 less sutures in the arteries and 4,5 less sutures in the veins. In Group I, the mean arterial anastomosis time was 17,21 minutes against 12,72 minutes in Group II. In the veins, the mean anastomosis time in Group I was 22,93 minutes against 16,57 minutes in Group II. The application of fibrin glue also reduced the flap ischemic time and the total operative time by 11,5 minutes and 15,67 minutes, respectively. The flaps\' survival rate was 90% in both groups. CONCLUSIONS: The application of fibrin glue in microvascular anastomoses was reliable and effective in this study.
50

Avaliação da escala MESS nas fraturas expostas da perna / MESS score evaluation in open leg fractures

Torres, Luciano Ruiz 18 September 2017 (has links)
INTRODUÇÃO: A escala MESS foi um instrumento desenvolvido para auxiliar o cirurgião na decisão entre amputar e preservar o membro inferior gravemente lesado. Neste estudo acompanhamos um grupo de pacientes com fratura exposta dos ossos da perna com MESS >= sete, preditivo para amputação, durante seu tratamento até a sua reabilitação completa. OBJETIVO: O objetivo do estudo foi determinar a relação de sucesso/insucesso funcional nos pacientes com escore MESS >= sete com o membro reconstruído no longo prazo (mínimo de dez anos de seguimento). MÉTODOS: Foram incluídos no estudo, os pacientes com fratura exposta Gustilo IIIB e IIIC dos ossos da perna com critérios de membros inferiores gravemente lesados modificados de Gregory e Bonanni e escore MESS >= sete. Os pacientes foram incluídos no período de 2003-2006. Os pacientes foram avaliados através da Medida de Independência Funcional e escala de incapacidade pela dor. RESULTADOS: Dos 26 pacientes selecionados, foram realizadas amputações em cinco e preservação do membro acometido, após intervenções, em 21 pacientes. Nove pacientes foram reavaliados após mais de 10 anos de seguimento. Destes, sete apresentavam o membro preservado e apenas um teve a reconstrução considerada como falha. Dos pacientes preservados, o paciente com fratura exposta Gustilo IIIC teve a reconstrução considerada falha. As duas amputações também foram consideradas funcionais. CONCLUSÃO: A escala MESS não é um bom instrumento para indicar amputação / INTRODUCTION: The MESS score was designed as a tool to assist the surgeon in deciding between amputate or preserve the severely injured lower limb. In this study we followed patients with severe open fractures of the leg with MESS >= seven, predictive for amputation during their treatment until their complete rehabilitation. OBJETIVE: The aim of the study was to determine the relative success / failure in patients with functional MESS score >= seven with the reconstructed member. METHODS: We included in the study, patients with open fractures Gustilo IIIB and IIIC of the leg with criteria for seriously injured lower limb modified by Gregory and Bonanni and MESS score >= seven. All patients were included from 2003 to 2006. Patients were evaluated through the Functional Independence Measure and Pain Disability Index. RESULTS: From selected 26 patients, five had below knee amputation and 21 after reconstructive procedures got limb salvage. Nine patients were evaluated after 10 years follow-up. Seven of them have the reconstructed limb, only one of these was considered as functional failure. Of the patients with lower limb reconstruction only Gustilo IIIC open fracture has a non-functional member. The two patients with amputation also have functional results. CONCLUSION: MESS is not a proper instrument to indicate amputation

Page generated in 0.1603 seconds