• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 6
  • Tagged with
  • 6
  • 6
  • 5
  • 4
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Circuit de lecture d'un magnétomètre à induction pour l'étude de plasmas atmosphériques sur la mission JUICE / Readout circuit of an induction magnétometer for the study of the jovian magnetosphere on JUICE mission

Varizat, Laurent 11 December 2017 (has links)
Les magnétomètres à induction sont utilisés dans de nombreux domaines d'exploration scientifique de la géophysique à l'astrophysique. Dans ces deux domaines l'étude des composantes magnétiques des ondes électromagnétiques naturelles requiert des instruments particulièrement performants: sensibles et présentant de faibles bruits intrinsèques pour accéder à des champs magnétiques de quelques fT/ . Dans le cas d'instruments scientifiques embarqués à bord de satellites, des contraintes en température, consommation, encombrement et de tenue en radiation s'ajoutent aux autres contraintes. Les technologies de circuits intégrés permettent une rupture technologique qui se traduit par une réduction de la taille des circuits électroniques embarqués d'un facteur supérieur à 1000 tout en améliorant les performances électriques et instrumentales (réduction de la consommation, des sources de bruit, augmentation de la bande passante et durcissement de l'électronique). Une première thèse au L2E (A. Rhouni) a montré la pertinence d'une technologie CMOS pour ce type d'instrumentation. Dans la présente thèse est décrite l'étude menée sur les circuits intégrés soumis à des environnements contraignants liés aux futures missions dans lesquelles ce type d'instrument doit être embarqué (Mission JUICE de l'ESA). Ces contraintes devenant de plus en plus sévères (dose de radiations supérieure à 300krad, température inférieure à 100 Kelvin ...), leur prise en compte dans tout le processus de conception est nécessaire. Une modélisation des effets de ces contraintes sur les composants de la technologie cible de circuits intégrés a été réalisée afin de pouvoir prendre en compte ces effets dès la conception. Enfin, ces modèles ont servi à la conception d'un circuit de lecture d'un magnétomètre à induction pour l'astrophysique. / Induction magnetometers are used in many fields of scientific exploration from geophysics to astrophysics. In these two fields, the study of the magnetic components of natural electromagnetic waves requires particularly powerful instruments: sensitive and with low intrinsic noises to access magnetic fields of some fT/ . In the case of scientific instruments carried on satellites, constraints on temperature, consumption, congestion and radiation resistance are added to the other constraints. Integrated circuit technologies allow technological breakthrough, which results in a reduction in the size of embedded electronic circuits by a factor greater than 1000, while improving electrical and instrumental performances (reduction in consumption, noise sources, bandwidth and hardening of the electronics). A first thesis at the L2E (A. Rhouni) showed the relevance of a CMOS technology for this type of instrumentation. In this thesis, we describe the study conducted on integrated circuits subject to environmental constraints related to the future missions in which this type of instrument must be embarked (Mission JUICE of ESA). These constraints are becoming more and more severe (radiation dose > 300krad, temperature less than 100 Kelvin ...), taking into account throughout the design process is necessary. A modeling of the effects of these constraints on the components of the integrated circuits technology has been carried out in order to be able to take these effects into account from the design stage. Finally, these models were used to design an induction magnetometer readout circuit for space instrumentation.
2

Matériaux lasers dopés à l'ion ytterbium : Performances lasers en pompage par diodes lasers et étude des propriétés thermo-optiques à des températures cryogéniques

Cardinali, Vanessa 10 May 2011 (has links) (PDF)
Dans les lasers, les gradients de température dans les milieux à gain provoquent des déformations de l'onde laser qui s'y propage. Le but de ma thèse est de mesurer les propriétés thermo-optiques (conductivité thermique, coefficient thermo-optique dn/dT, coefficient de dilatation) de nouveaux matériaux lasers permettant d'atteindre des énergies élevées à de hautes cadences de tir. Ces matériaux sont des céramiques sesquioxydes de scandium Sc2O3, de lutétium Lu2O3 et d'yttrium Y2O3 dopées ytterbium. Les mesures se font à basse température (température de l'azote liquide, 77 K) car les propriétés thermiques sont améliorées lorsque la température du matériau diminue. Ces matériaux ont également été testés en configuration d'oscillateur laser relaxé, montrant ainsi tout l'intérêt de travailler à basse température. Les mesures de ces propriétés représentent un enjeu majeur pour le développement des lasers de forte puissance, d'autant plus que les données de la littérature concernant ces matériaux, dans ces domaines de température, sont quasiment inexistantes. D'autres matériaux comme des cristaux et des céramiques de YAG, des cristaux de fluorure de calcium CaF2 dopés ytterbium, et des verres phosphates dopés néodyme ont également été testés.
3

Etude de l’émissivité des solides et liquides des températures cryogéniques aux très hautes températures / Study on the emissivity of solid and liquid materials from cryogenic temperature to very high temperature

Wang, Xingkai 12 November 2015 (has links)
L’échange d’énergie par rayonnement est proportionnel à l’émissivité. Ce facteur dépend de la température et de la longueur d’onde mais aussi de l’état de surface, de la composition et de la phase. Sa mesure précise est donc toujours un défi à cause des influences connues ou inconnues. Par rapport à d’autres travaux, le but de ce travail est de l’étudier dans des conditions extrêmes, des températures cryogéniques aux hautes températures : Nous avons ainsi étudié à 80K l’absorption d’un diélectrique pour la protection thermique d’un satellite et celles de surfaces en or de différentes rugosités. A la température ambiante nous avons déterminé par une méthode en réflexion, l’émission de vitrages dans le but de la recherche d‘économie d’énergie. Nous avons aussi étudié la variation de l’émissivité pendant le changement de phase solidus-liquidus et α-β de second ordre. Autour de 100°C le soufre devient plus émissif lorsqu’il passe du solide au liquide mais par contre il n’y a pas de différence sur l’émissivité pour ses deux variétés allotropiques principales. A une beaucoup plus haute température, le silicium liquide se comporte comme un métal avec une émissivité très faible et un saut net a été constaté à son passage au point de fusion. Une variation marquée de l’émissivité pour les deux phases solides du SiC a été observée entre 8-11μm dans notre étude. Contrairement aux résultats de la littérature, les sommets d’émissivité diminuent progressivement avec l’augmentation de la température. Enfin trois points X, longueur d’onde où l’émissivité ne dépend pas de la température, ont été observés pour chaque phase. / Heat transferred by radiation is proportional to the emissivity. This coefficient depends not only on the wavelength and the temperature, but also on the surfaceroughness, the chemical composition and the phase. A precise measurement is always a challenge because of the known and unknown factors. Compared with others, this thesis aims at the studies in extreme conditions, from cryogenic temperature to very high temperature: The absorptivity of a dielectric applied to the thermal protector for the satellite and the emissivity of gold surfaces with different roughness have been measured at 80K. The emissivity of different windows has been determined by the reflection method at room temperature for the research of energy saving. We have also studied the variation of the emissivity during the solid to liquid and α-β phase transition. The sulfur becomes more emissive when it changes from solid to liquid around 100°C, but there is no difference on the emissivity between its two major allotropies. The liquid silicon behaves like a metal with a very low emissivity and an obvious bound has been measured when it crosses its melting point. A marked variation of the emissivity of SiC for its two solid-state phases has been observed between 8-11μm. Contrary to other results, the peak values of the emissivity attenuate with the increase of temperature. Finally, three X points at which the emissivity doesn’t depend on the temperature have been measured for each phase.
4

Étude de la luminescence de nanocristaux semi-conducteurs couplés avec des structures plasmoniques à températures ambiante et cryogénique / Photoluminescence of semi-conducting nanocrystals coupled to plasmonic structures at room temperature and cryogenic temperature

Eloi, Fabien 05 December 2016 (has links)
Les nanocristaux semi-conducteurs colloïdaux possèdent des propriétés photo-physiques qui en font des objets de choix pour des applications variées, comme le marquage biologique, le photovoltaïque ou encore l'optique quantique. Dans cette thèse, nous étudions les modifications, introduites par des réseaux d'or, de la fluorescence de nanocristaux CdSe/CdS à coquille épaisse. Nous présentons tout d'abord les propriétés fondamentales de ces nanocristaux de CdSe/CdS puis la manière dont leurs propriétés d'émission peuvent être contrôlées par l'environnement électromagnétique, en détaillant en particulier le cas d'un couplage avec des plasmons de surface. Des simulations réalisées par nos collaborateurs du LICB dans le cadre d'un projet ANR sont ensuite comparées à nos mesures expérimentales. Nous observons que le couplage des nano-émetteurs individuels au réseau d'or permet à la fois d'accélérer l'émission spontanée et de mieux la collecter. Les structures métalliques sont optimisées pour que les améliorations détectées soient peu sensibles à la position de l'émetteur. Un effet supplémentaire est le contrôle de la polarisation de l'émission qui se révèle être fixée pa r le réseau. Nous rapportons également des changements dans la statistique temporelle d'émission des photons et notamment la suppression totale du scintillement. Les métaux étant connus pour leurs pertes ohmiques, des expériences ont été réalisées pour montrer que les pertes non radiatives qu'elles entraînent peuvent être réduites à basse température. Nous avons examiné le cas d'une surface d'or plane ainsi que des réseaux linéaires et circulaires. Enfin, une nouvelle méthode de post-traitement a été développée en parallèle. Elle permet par exemple d'étudier les variations de l'efficacité quantique bi-excitonique dans des nanocristaux enrobés d'or suivant l'état de charge de l'émetteur. / Colloidal semiconductor nanocrystals are fluorescent nano-objects exhibiting discrete energy levels which justify their second appellation: quantum dots (QDs). Due to their high efficiency and ease of use, they find potential applications in a wide range of fields. Their usefulness for biological labeling, optoelectronic components in flat screens, light harvesting or quantum optics has been demonstrated by many studies. In this thesis, we use gold gratings in order to modify the emission properties of CdSe/CdS core-shell nanocrystals. After a brief presentation of their electronic and fluorescence properties, we explain how those properties can be modified by the control of the electromagnetic environment with particular care to the case of surface plasmons. We then show through experiment and simulations that those plasmons enable better collection efficiency, faster photo-luminescence decay rates, and polarized emission without being particularly restricting towards QD positioning. Changes in the emission statistics are also observed, notably total suppression of the blinking in the fluorescence intensity. Further experiments at low temperature have been realized in order to assess the importance of the gold ohmic losses. We investigated the case of a flat gold film as well as linear and circular gratings. A new post-selection method is also introduced and used to study the variations of the bi-excitonic quantum yield for nanocrystals embedded in a gold nano-resonator as a function of the ionization state of the emitter.
5

Spectroscopie d'absorption et d'émission des excitons dans les nanotubes de carbone / Absorption and emission spectroscopy of exciton in carbon nanotubes

Raynaud, Christophe 29 November 2018 (has links)
Les propriétés optiques de nanotubes de carbone sont décrites idéalement parla physique d’un objet unidimensionnel, donnant lieu notamment à l’apparition des excitons pour décrire les transitions optiques de ces objets. Les expériences d’optique(émission, absorption) réalisées sur ces objets à température ambiante et sur des ensemble d’objets ont permis de confirmer les prédictions théoriques basées sur la physique des objets 1D. Mais à température cryogénique et à l’échelle de l’objet unique,les propriétés optiques observées expérimentalement sont systématiquement très éloignées de celles d’un objet 1D. On peut notamment citer l’apparition de propriétés comme l’émission de photons uniques, qui a largement contribué à l’intensification de la recherche sur ces objets pour des applications en photonique quantique. Ces propriétés sont attribuées à la localisation des excitons le long de l’axe des nanotubes dans des puits de potentiel créés aléatoirement par l’interaction des nanotubes avec leur environnement. Les propriétés optiques sont alors proches de celles des objets0D, et sont fortement modulées par l’environnement. Les mécanismes et l’origine de la localisation et la connaissance physique de ces puits sont encore très limités. Ce travail montre d’une part le développement d’une technique d’absorption sur objet individuel et la caractérisation de sa sensibilité, et d’autre part l’étude statistique de l’émission de nanotubes à température cryogénique. Les résultats obtenus par une technique de super-résolution couplée à une imagerie hyper-spectrale montrent les grandeurs caractéristiques des puits de potentiels au sein de nanotubes individuels.Un dispositif expérimental de photoluminescence résolue en excitation implémenté au cours de ce travail a également montré une modification de l’état excitonique fondamental par l’environnement, avec l’apparition d’une discrétisation spatiale et spectrale de l’état fondamental délocalisé en une multitude d’états localisés. / The optical properties of carbon nanotubes are ideally described by the physicsof a one-dimensional object, giving rise in particular to the emergence of excitons todescribe the optical transitions of these objects. The optical experiments (emission,absorption) carried out on these objects at ambient temperature and on ensemblesconfirm the theoretical predictions based on the physics of 1D objects. But atcryogenic temperature and at the single emitter scale, the optical properties observedexperimentally are systematically different from those of a 1D object. One can citethe emergence of properties such as photon antibunching, which largely contributed tothe intensification of research on these objects for applications in quantum photonics.These properties are attributed to the localization of excitons along the nanotube axisin local potential wells (traps) created randomly by the interaction of nanotubes withtheir environment. The optical properties are then close to those of 0D objects, andare strongly modulated by the environment. The mechanisms and the origin of thelocalization and the physical knowledge of these traps are still very limited. This workshows on the one hand the development of an absorption setup on individual objectand the characterization of its sensitivity, and on the other hand the statistical studyof the emission of nanotubes at cryogenic temperature in a micro-photoluminescencesetup. The results obtained in the later setup by a super-resolution technique coupledwith hyper-spectral imaging show the characteristic quantities of potential wellswithin individual nanotubes. An experimental excitation-resolved photoluminescencesetup implemented during this work also showed a modification of the fundamentalexcitonic state by the environment, with the emergence of a spatial and spectraldiscretization of the delocalized ground state in a multitude of localized states.
6

Résonateurs à ondes acoustiques de volume piégées à très basses température : Applications à l'optomécanique / Bulk acoustics waves resonators trapped at very low temperatures : Optomechanical applications

Bon, Jérémy 12 December 2018 (has links)
Depuis plusieurs années, le département Temps-Fréquence de l’institut FEMTO-ST mène une étude sur le comportement des résonateurs à ondes acoustiques de volume à énergie piégée dans des cristaux à quartz à température cryogénique, typiquement proche de 4 K. Les performances en termes de coefficient de qualité mécanique relevé à ces températures, plusieurs milliards à quelques dizaines de MHz, font des cavités acoustiques en quartz de bons candidats pour des sources de fréquences cryogéniques ultrastables.Les travaux présentés dans ce manuscrit s’inscrivent dans la continuité de ce programme d’étude. Ils visent à consolider l’intérêt du quartz mais aussi à envisager des solutions alternatives à base de matériaux à très faibles pertes acoustiques mais non piézoélectriques pour lesquels l’excitation optique est une alternative crédible. Les présents travaux peuvent être résumés en trois parties majeures :- La première partie a été réalisée dans le but de déterminer une coupe de quartz possédant un point d’inversion sur sa caractéristique fréquence-température aux températures cryogéniques. La seule régulation de température du résonateur d’une source de fréquence ultrastable est en effet insuffisante sans l’existence d’un tel point qui doit servir de point de fonctionnement à la régulation thermique. La recherche d’une coupe compensée a nécessité une campagne préliminaire de mesure des coefficients de température des coefficients élastiques du matériau, inconnus à basses températures. Il a alors été possible, à partir de la connaissance de ces coefficients, d’identifier par le calcul puis de réaliser une coupe remplissant les conditions recherchées.- La seconde partie a pour objectif de faire la preuve de concept consistant à utiliser une cavité acoustique en quartz en cavité optique. Dans sa version de base, le résonateur à quartz à onde de volume piégée est plan-convexe (pour assurer le piégeage) et à électrodes (métalliques pour assurer l’excitation électrique !) déposées sur chacune de ses faces. Il est démontré, théoriquement et expérimentalement, qu’une telle géométrie fonctionne en cavité optique, avec son avantage de simplicité mais avec ses limites. Cette structure de base doit être mise à profit pour le couplage optomécanique abordé en troisième partie et constitue le socle de conception de dispositifs optomécaniques plus performants.- La troisième partie est consacrée à l’évaluation de la pertinence du couplage optomécanique de tels dispositifs fonctionnant à température cryogénique. Une étude portant sur la quantification théorique du couplage optomécanique que peut atteindre une telle cavité a été réalisée. / For a few years, the Time and Frequency department in FEMTO-ST Insitute has been leading research about the behavior of Bulk Acoustic Wave (BAW) trapped in quartz crystal at cryogenic temperatures (near 4K).The measured quality factor are around a few billions at few tens of MHz for such temperatures. Acoustical quartz cavities are therefore good candidates for ultrastable cryogenic frequency sources. The work presented here is in the natural continuation of the research cited above. They aim at strenghtening the interest for quartz crystal, but also to consider alternative solutions with non-piezoelectric material with very-low acoustical losses, for which optical excitation is an option. The following work can be summed up in three main parts:- The first part is about the determination of a quartz crystal cut for which a turnover point exists in the frequency-temperature curve in the cryogenic region. Indeed, it is not enough to barely control the temperature in an ultrastable frequency source. Such a turnover point needs to be the operation point for thermal regulation. Searching a compensated cut arose the need for a preliminary measurements campaign of thermal coefficients of elastics coefficients of the material, which were unknown at low temperature. It was then possible, based on these coefficients, to calculate and even realize a cut fulfilling the required condition.- The second part had the objective to demonstrate conceptually that using a quartz acoustical cavity as an optical cavity was feasible. In its basic scheme, a BAW quartz resonator is plano-convex (to ensure the trapping of the acoustic wave) and has electrodes (metal-made to ensure electrical excitation) deposited on each face. It has been demonstrated, both theoretically and experimentally, that such a geometry works fine as an optical cavity, with its corresponding advantages and limitations. This scheme is used for the optomechanical coupling discussed in the third part and constitutes the very base for more efficient optomechanical devices.- The third part is dedicated to the evaluation of how efficient will such devices be while functioning at cryogenic temperature. A theoretical quantification of the optomechanical coupling that these cavities might reach is also presented.

Page generated in 0.0653 seconds