• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 140
  • 120
  • Tagged with
  • 260
  • 207
  • 173
  • 111
  • 101
  • 52
  • 47
  • 46
  • 44
  • 35
  • 34
  • 30
  • 27
  • 26
  • 25
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
91

Thermal conductivity Measurement of PEDOT:PSS by 3-omega Technique

Faghani, Farshad January 2010 (has links)
Conducting polymers (CP) have received great attention in both academic and industrial areas in recent years. They exhibit unique characteristics (electrical conductivity, solution processability, light weight and flexibility) which make them promising candidates for being used in many electronic applications. Recently, there is a renewed interest to consider those materials for thermoelectric generators that is for energy harvesting purposes. Therefore, it is of great importance to have in depth understanding of their thermal and electrical characteristics. In this diploma work, the thermal conductivity of PEDOT:PSS is investigated by applying 3-omega technique which is accounted for a transient method of measuring thermal conductivity and specific heat. To validate the measurement setup, two benchmark substrates with known properties are explored and the results for thermal conductivity are nicely in agreement with their actual values with a reasonable error percentage. All measurements are carried out inside a Cryogenic probe station with vacuum condition. Then a bulk scale of PEDOT:PSS with sufficient thickness is made and investigated. Although, it is a great challenge to make a thick layer of this polymer since it needs to be both solid state and has as smooth surface as possible for further gold deposition. The results display a thermal conductivity range between 0.20 and 0.25 (W.m-1.K-1) at room temperature which is a nice approximation of what has been reported so far. The discrepancy is mainly due to some uncertainty about the exact value of temperature coefficient of resistance (TCR) of the heater and also heat losses especially in case of heaters with larger surface area. Moreover, thermal conductivity of PEDOT:PSS is studied over a wide temperature band ranging from 223 - 373 K.
92

Småskalig säsongslagring av solenergi för uppvärmning av bostäder : Simulering av lagerutformning och konsekvensen av adderade uppvärmningsbehov motsvarande en pool och ett atrium / Small scale seasonal storage of solar energy for domestic heating : Simulation of storage design and the consequence of added heating demands corresponding to a pool and an atrium

Fryklund, Jenny January 2010 (has links)
The sun is a huge energy source with great potential of providing energy to the heating of homes and other buildings in an environmentally sustainable manner. In order to provide buildings with energy from the sun it is necessary to transfer the energy supply over time to when the demand arises. By storing the heat in a seasonal storage, solar energy from the summer can be used in the winter when the demand for heating is greatest. Today's existing plants are mainly in Europe and particularly in Germany. These facilities are designed to supply heat demands greater than 400 MWh and covers about 40-50 % of this need which consists of energy for space heating and domestic hot water. How much of the heat demand that is covered, the solar fraction, is partly due to losses from the storage which in turn is connected to the surface area of the storage. The bigger a storage, the smaller the losses because of the decreasing relationship between surface area and storage volume. Looking at the size of the seasonal storages that are currently in operation, the question if seasonal storage is also suitable for installations designed for heat demands smaller than 400 MWh arises. Jonas Haglund at the architect office Skanark AB in Karlstad is planning an accommodation of 40 flats and hopes that seasonal stored solar energy can serve as the main energy source for space heating and hot water. In order to make housing more attractive he is considering the idea of adding other features, like a pool and an atrium, that also require heating but with lower temperature requirements. Haglund would like to investigate whether the efficiency of the solar collector increases when the extra energy demands are added and if the energy cost, for those demands, in this way can be reduced. The purpose of this study is to investigate the possibility of covering a large fraction of a small-scale annual heat demand corresponding to about 40 newly built apartments. The study shall present the solar fractions that can be achieved with different storage concepts when storage size and collector area is varied. The study will also answer how the solar fraction will change if a heating demand with lower temperature requirements and varied character is added to the basic domestic heating and if the added energy demand to some extent can be free. These questions are answered by calculations and simulations with the simulation software COMSOL Multiphysics. The results show that it is possible to obtain solar fractions above 80% with sufficient collector area. Suitable storage volume varies depending on the specific storage concept. Simulations of seasonal storage in a tank show that a storage volume of 13 m3/MWh is an appropriate size, while the corresponding figure for duct storage in clay is 20 m3/MWh. An added heating demand of low temperature character increases the efficiency of the solar panels and creates, so called, free energy. / Examensarbete
93

Optimering av ventilationsbehovet till tvättapparat

Eriksson, Fredrik January 2011 (has links)
Syftet med detta examensarbete är att undersöka om det går att minska frånluftsventilationen till tvättapparater för pappersmassaindustrin. Genom att mäta flödet för frånluftsventilationen och mätinstrument vid ångläckaget har undersökningar gjorts om det går att minska frånluftsventilationen.  Examensarbetet har utförds för företaget Metso i Sundsvall som bl.a. tillverkar hela systemlösningar till pappersmassaindustrin. Mätningarna har gjorts på SCA Östrand i Timrå som är en pappersmassa tillverkare.  Inledningsvis ges en presentation över hur pappersmassatillverkning går till och sedan ges en mera genomgående beskrivning av hur Twinroll tvättapparat, spädskruv och standpipe fungerar. I teori delen tas det upp vilka saker som påverkar ångläckaget för tvättapparaten. Det som påverkar är sambanden i ideala gaslagen, fukt och avdunstning. För att beräkna hastigheten med pitotrör har Bernoullis ekvation härleds i teoridelen.   Mätningarna gick ut på först att fastställa frånluftsventilationsflödet från tvättapparaten. Dessa mätningar gav problem i början eftersom frånluften hade hög temperatur och ånghalt men sedan kunde flödet mätas. För mätningarna användes pitotrör och vinghjulsmätare.  För att fastställa vilket det minsta frånluftsventilationsflöde är innan det bildas ångläckage från tvättapparaten användes för det mänskliga ögat. Det visade att det inte gick att visa hur ångläckage ändrades genom tiden. Mätningar av temperatur- och RH-givare gav dåliga värden förutom när en tillfällig produktionsstörning inträffade. Då fastställs att när produktionen, temperaturen på pappersmassan- och spritsen går ner minskas ångläckaget. RH-givaren visade felvärden pga att inte synbart ångläckage inträffar och att spritsen går i intervaller.  Konceptgeneringen visade att minskade av kåpansluftvolym och ångläckagearean troligtvis är dem bästa lösningarna. Dem andra lösningarna kan testas om energipriserna går upp och då lär dem bli lönsamma.
94

Fönster i ombyggnad

Remazan, Azad January 2012 (has links)
I dagens samhälle ställs allt högre krav på att energieffektivisera byggnader, därmed ställs även krav på att energieffektivisera befintliga byggnaderna. Ett av Sveriges nationella mål är att energianvändningen inom bebyggelse halveras till år 2050 jämfört med 1995. Examensarbete har skrivit för EKG-projekt, en vägledning för fastighetsägarna som deltar i projektet vid eventuella fönsterbyten. Denna uppsatts belyser viktiga områden och idéer inom modern fönsterkonstruktion, med tillhörande undersökningar samt en marknadsundersökning för fönster och dess kostnader. Detta examensarbete innefattar även vilka tankar man bör ha i åtanke vid bestämt fönsterbyte ur den arkitektoniska synvinkel samt en energisimulering för ett rum, där fönstret byts ut mot en lågenergi fönster. Via metoden som användes blev resultatet för energisimuleringen naturligtvis lägre energiförluster genom ett lågenergi fönsterbyte samt att den termiska komforten förbättrades. Detta har lett i sin tur att vistelsezonen har ökats samt det termiska klimatindexen, Predicted Mean Vote (PMV), har för förbättras aningen. / Today's society is increasingly demanding that every building should become even more energy efficiency. One of Sweden’s domestic aims is at 2050 decrease the energy use of the building stock with 50 % compared with the energy use of 1995. This thesis is written to the EKG-projects where the thesis is a guideline for property-owners that is involved in the whole project, EKG-projects. The main reason of the thesis is if the property owner decides to replace its windows to more energy efficient windows. The thesis also highlights other important areas and concepts in modern window constructions and also research and a marketing evaluation for windows and its expenditure. The thesis also includes thoughts and remembrance when a person has decided for window replacement and also about the architectural point of view and energy simulation of a room when a window is being replaced. By the method used in the thesis the results for the energy simulation was much lower energy losses when a window replacement with low energy window took place. As well the thermal comfort improved. This has in turn let that the “stay-area” has increased and the thermal climate indices, Predicted Mean Vote (PMV) has improved slightly.
95

Absorptionskyla i Linköpings energisystem : kompressorkyla vs absorptionskyla / Absorption Cooling in the Energy System of Linköping

Pauline, Ekoff, Johanna, Lund January 2006 (has links)
Huvudsyftet med arbetet har varit att undersöka potentialen för värmedriven kylproduktion, dvs. absorptionskyla, i Linköpings energisystem. Bakgrunden är att många energibolag söker efter nya avsättningsområden för fjärrvärme pga. det överskott på värme som finns sommartid i energisystem med kraftvärme. Dessutom förväntas elpriserna fortsätta stiga då Sverige med stor sannolikhet kommer att följa resten av Europa och gå från ett energidimensionerat system till ett effektdimensionerat system. Till följd av detta blir energieffektiviserande åtgärder allt viktigare och absorptionskyla innebär att mer el kan produceras i ett system med kraftvärme, istället för att konsumeras. Det finns två typer av absorptionskylmaskiner (ABS) tillgängliga på marknaden, antingen har de fjärrvärme eller ånga som drivmedel. Den typ av ABS som drivs av fjärrvärme lämpar sig för produktion av komfortkyla, dvs. kyla som inte behöver komma ned till så låga temperaturer. Ångdriven ABS kan däremot komma ned till lägre temperaturer, något som kan passa vid processkyla. En förutsättning för absorptionskyla är tillgång till billig värme/ånga. Tekniska Verken har tack vare avfallsförbränning tillgång till billig värme. Ångan i systemet produceras däremot idag med olja och el, något som gör det dyrare att generera absorptionskyla med hjälp av ånga. En fallstudie utfördes på de två industrierna Linköpingsmejeriet och Swedish Meats där anslutningsmöjligheterna för absorptionskyla undersöktes. Främst behovet av processkyla har undersökts då det var betydligt större än behovet av komfortkyla. Ett antal fall med olika förutsättningar för att tillgodose dessa kylbehov till de båda industrierna har simulerats i MODEST. Utifrån de resultat som erhållits har följande slutsatser dragits. • I dagsläget finns inte tillräckligt med ångproduktion i systemet för att tillgodose både det befintliga ångbehovet samt den mängd ånga som behövs för att framställa kylan. • En investering i nya biopannor till ett kraftvärmeverk kan ge tillräcklig mängd billig ånga och värme för att ge lönsamhet i värmedriven kylproduktion. • Koldioxidutsläppen, lokala såväl som globala, minskar som en följd av övergång från el-kompressorer till absorptionskylmaskiner. En investering i nya biopannor skulle minska utsläppen ytterligare, då fossilt bränsle ersätts. • En investering i en litiumbromid absorptionskylmaskin är inte lönsam vid en så pass liten efterfråga som har varit aktuellt i de undersökta fallen. / The main purpose of this thesis has been to look in to the potential of a production of district cooling using heat as the source of power, i.e. absorptions cooling, in the energy system of Linköping. In the light of the fact that many energy companies are looking for new markets for district heating due to the surplus of heat in the summertime in an energy system with CHP (Combined Heat and Power). Furthermore, the price on electricity is expected to continue to rise since Sweden is most likely to follow Europe’s lead and embrace a power dimensioned energy system. As a result of that transition, energy efficient measures will be more important and absorption cooling implies that more electricity can be produced, instead of consumed, in a CHP system. There are two different types of absorption cooling machines available in the market, with either district heating or steam as the source of power. A machine using district heating as the source of power is most suitable to produce comfort cooling i.e. the cold does not need to attain such low temperatures. A steam driven absorption cooling machine is able to attain the very low temperatures needed for cooling used in the processing industry. A condition for absorption cooling is the access to low-cost heat/steam. Tekniska Verken (an energy company) has due to waste incineration access to low-cost heat. The steam in the energy system is produced with oil and electricity, which makes it more expensive to generate absorption cooling with steam as the power source. A casestudy was preformed at two industries in Linköping, Linköpingsmejeriet and Swedish Meats, where the possibility for connection of district cooling was examined. Mainly the cooling needed in the processing industry has been examined as this is need is considerably larger than the need for comfort cooling. A number of cases with different conditions for producing district cooling have been simulated in MODEST. The following conclusions have been drawn based on the results of the simulations. • In the energy system of today there is not enough steam production to fulfil both the current need for steam and the amount of steam needed for cooling production. • An investment in new CHP-plants using biomass fuels will generate enough heat and steam to be profitable for cooling production using heat as a source of power. • The emission of carbon dioxide will decrease as a result of the transmission from compression cooling to absorption cooling. The emission will decrease further if an investment in new CHP plants with biomass fuels is carried out. This will then replace the use of fossil fuels. • An investment in lithium bromide absorptions cooler will not be profitable with such a small demand as the one in question.
96

Småskalig elproduktion i Arvika

Pettersson, Niklas, Eriksson, Nils January 2006 (has links)
Arvika Fjärrvärme AB, a district heating company from Arvika, today cover 74 % of their total energy production with biofuel wich runs a 16 MW bioler giving process water at saturated liquid state. In recent years Vaporel AB has introduced a new tecnique that gives an external generation of steam after boilers. The concept is built on an adiabatic pressure drop of the saturated liquid in a so called Flashbox which makes a small part of the liquid to evaporate. The generated steam is lead into a turbine where electricity is in a conventional manner. The purpose with this rapport was to do a basic study for the specific system at Arvika where it’s possible to see the potential production of electricity that follows an installation of a flasbox. The final goal was to introduce an economic analysis of a flashox installation at given conditions. To reach our goals we have created a model in Excel where we used the given conditions at Arvika Fjärrvärme to do our calculations. The model has been tested at three different states, of process water returning to potboiler, to be able to decide the optimal operation for the system at present. The studies have resulted in a pressure of the processwater at 14,5 bar (at) and a pressuredrop to 9,5 bar (at) in the flashbox. The condenser pressure is set to 0,5 bar (at) what is equal to 81 ˚C. Energy to the district heating net is produced in the condenser and heat exchanger. The result of our calculations clearly shows that to reach the highest turbine-efficiency as possible and gain the largest profit the highest process-waterflow possible should be used. That means 70 kg/s after present conditions. At the highest boiler efficiency the turbine will produce 694 kW. At this state the water that returns to the boiler will be at temperature 148 ˚C (14, 5 bar). Totally during a year the production of electric energy could reach 2, 47 GWh/year. The energy used by the pumps will increase with 0,21 GWh over the year at that state. Included all economic factors this will generate a profit of 0, 97 million (SEK)/year. To make an installation of a flashbox system more profitable an increased generation of electricity have to be made. This could be done by an installation of new pumps to be able to run the process-water at a larger flow to increase the amount of steam made in the flashbox. / Arvika fjärrvärme producerar idag 74% av sitt värmeunderlag via en hetvattenpanna som drivs med biobränsle och har en maxeffekt på 16 MW. På senare år har företaget Vaporel AB introducerat en ny teknik på marknaden som ger en extern ångproduktion efter hetvattenpannor. Konceptet är byggt på en trycksänkning som medför att delar av det mättade vattnet förångas efter att ha letts in i en så kallad flashbox. Efter flashboxen äntrar ångan en turbin där el produceras på konventionellt vis. Syftet med denna rapport har varit att ta fram en grundläggande studie för Arvikas specifika system där det är möjligt att se den potentiella elproduktionen vid en flashboxinstallation. Det slutgiltiga målet med rapporten har varit att kunna presentera en lönsamhetsbedömning för en flashboxinstallation vid givna driftfall. För att kunna uppfylla uppsatta mål har en Excelmodell konstruerats där beräkningar utförts efter givna förutsättningar, detta utefter tre olika driftfall för att kunna fastställa den mest optimala driften för systemet i dagsläget. Studierna har lett fram till att vi har kunnat fastställa ett maximalt tryck efter pannan på 14,5 bar (at) samt en trycksänkning över flashboxen till 9,5 bar. Kondensortryck efter turbinen har satts till 0,5 bar(a) vilket ger en kondensations temperatur motsvarande 81 ˚C. Energi till att värma fjärrvärmevattnet tas via kondensorn samt en värmeväxlare. Resultatet av våra beräkningar visar tydligt att vi för att nå en så hög turbineffekt som möjligt och därmed en större lönsamhet skall ha ett så högt processvattenflöde som tillåts, enligt dagens förutsättningar 70 l/s. Vid högsta panneffekten kommer turbinen att ge 694 kW, enligt Excelmodellen, vid en returtemperatur till pannan satt till 148 ˚C. Sammanlagt under året, med Arvikas varaktighetsdiagram som grund, kommer vi att kunna producera 2,47 GWh el/år varav pumparna kommer att kräva 0,21 GWh el extra per år. Med alla ekonomiska faktorer inräknade så kommer detta att ge en vinstkalkyl på 0,97 miljoner /år. För att kunna göra dessa installationer lönsamma krävs att vi ökar elproduktionen och därmed den årliga vinsten, detta skulle kunna göras i och med installation av nya pumpar för att uppnå ett större flöde i pannkretsen. Vidare bör en studie göras för att bedöma lönsamheten gällande en ombyggnad av rökgaskondenseringen för att kunna klara en större effekt och därmed kunna använda högre returtemperaturer till biopannan. Detta skulle generera ett högre genomsnittligt flöde över året.
97

Simulation and Evaluation of Two Different Skin Thermocouples : A Comparison made with Respect to Measured Temperature

Lundh, Joel January 2007 (has links)
The demand for more accurate measurements is increasing in today’s industry. One reason for this is to optimize production and thus maximize profits. Another reason is that in some cases government regulations dictate that supervision of certain parameters must be followed. At Preemraff Lysekil there are basically four reasons for measuring skin temperatures inside fired process heaters, namely; because of government regulations, in order to estimate the load of the fired process heater, to estimate the lifetime of the tubes inside the fired process heater and finally, to determine the need of decoking. However, only the first three of these reasons are applied to H2301/2/3. The current skin thermocouple design has been in use for many years and now the question of how well it measures surface temperature has risen. Furthermore a new weld-free design is under consideration to replace the old skin thermocouple design. Another question is therefore how well the new design can measure the surface temperature under the same operating conditions as the old one. In order to evaluate this, three–dimensional computer simulations were made of the different designs. As this thesis will show, the differences in calculated skin thermocouple temperature and calculated surface temperature is about the same for the two designs. However, the current design will show a lower temperature than the surface temperature, while the new design will show a higher temperature. Regarding the core of the skin thermocouple designs, namely the thermocouple, no hard conclusions can be drawn, although the industry appears to favor type ’N’ over type ’K’.
98

Heat Transfer Correlations Between a Heated Surface and Liquid & Superfluid Helium : For Better Understanding of the Thermal Stability of the Superconducting Dipole Magnets in the LHC at CERN

Lantz, Jonas January 2007 (has links)
<p>This thesis is a study of the heat transfer correlations between a wire and liquid helium cooled to either 1.9 or 4.3 K. The wire resembles a part of a superconducting magnet used in the Large Hadron Collider (LHC) particle accelerator currently being built at CERN. The magnets are cooled to 1.9 K and using helium as a coolant is very efficient, especially at extremely low temperatures since it then becomes a superfluid with an apparent infinite thermal conductivity. The cooling of the magnet is very important, since the superconducting wires need to be thermally stable.</p><p>Thermal stability means that a superconductive magnet can remain superconducting, even if a part of the magnet becomes normal conductive due to a temperature increase. This means that if heat is generated in a wire, it must be transferred to the helium by some sort of heat transfer mechanism, or along the wire or to the neighbouring wires by conduction. Since the magnets need to be superconductive for the operation of the particle accelerator, it is crucial to keep the wires cold. Therefore, it is necessary to understand the heat transfer mechanisms from the wires to the liquid helium.</p><p>The scope of this thesis was to describe the heat transfer mechanisms from a heater immersed in liquid and superfluid helium. By performing both experiments and simulations, it was possible to determine properties like heat transfer correlations, critical heat flux limits, and the differences between transient and steady-state heat flow. The measured values were in good agreement with values found in literature with a few exceptions. These differences could be due to measurement errors. A numerical program was written in Matlab and it was able to simulate the experimental temperature and heat flux response with good accuracy for a given heat generation.</p>
99

Industrikombinat : en affärsmöjlighet för Vattenfall

Borg, Fredrik, Stralström, Krister January 2008 (has links)
<p>Syftet med detta arbete är att identifiera geografiska platser i Sverige där det finns affärsmöjligheter för Vattenfall med industrikombinat som grundtanke samt definiera industrikombinatets uppbyggnad. Då arbetet skrivs för Vattenfall Elproduktion Norden ska elproduktion ingå i industrikombinatet. Begreppet industrikombinat används i detta arbete för att beskriva samarbeten där restvärme från en produktionsenhet används som primärvärme i en annan produktionsenhet</p><p>Branscherna med störst energianvändning i Sverige anses vara mest intressanta att samarbeta med eftersom det i dessa branscher bör finnas affärsmöjligheter med störst potential. Industrier ur dessa branscher kartläggs och placeras ut på en Sverigekarta för att lokalisera geografiska områden med stor energianvändning. Även enskilda industrier med stora energibehov ur andra branscher placeras ut på kartan. För geografiska områden där affärsmöjligheter identifieras beskrivs det föreslagna industrikombinatets uppbyggnad och nuvärdet av den föreslagna affärsmöjligheten presenteras.</p><p>Affärsmöjligheterna i Grycksbo och området Ludvika och Grängesberg anses mest intressanta med hänsyn till investeringarnas nuvärde och genomförbarhet. I dessa områden genomförs en fördjupad analys. I analyserna optimeras de berörda industriernas värmesamarbeten. Optimeringen görs genom att en modell av energi-systemet för de berörda industrierna byggs upp och optimeras i programmet Modest.</p><p>Affärsmöjligheten i Grycksbo är mycket lönsam. Nuvärdet för den affärsmöjligheten är 613 MSEK sett över en tioårsperiod med 6 % kalkylränta. Affärsmöjligheten är att investera 541 MSEK i en ny kraftvärmeanläggning för att förse Grycksbo Paper med den ånga de behöver. Affärsmöjligheter som liknar denna identifieras också vid pappersbruken i Munkedal och Åsensbruk.</p><p>I Ludvika och Grängesberg är nuvärdet av affärsmöjligheten -12 MSEK sett över en tioårsperiod med 6 % kalkylränta. Affärsmöjligheten är att investera 247 MSEK i en kraftvärmeanläggning och en förbindelse mellan fjärrvärmenäten i Ludvika och Grängesberg. Kraftvärmeanläggningen kan då förse Spendrups med den ånga de behöver samt leverera värme till fjärrvärmenäten. Lönsamheten för denna affärsmöjlighet påverkas kraftigt av investeringskostnaden för kraftvärmeanläggningen. Kostnaden för kraftvärmeanläggningar har stigit mycket de senaste åren. Om kostnaden för kraftvärmeanläggningar skulle sjunka skulle investeringen i Ludvika och Grängesberg vara mer lönsam.</p><p>Vattenfall rekommenderas ta kontakt med Grycksbo Paper samt Arctic Paper i Åsensbruk och Munkedal för att diskutera de affärsmöjligheter som presenteras i denna rapport. Dessutom rekommenderas Vattenfall att föra samtal med Spendrups i Grängesberg angående samarbete och bevaka kostnaden för kraftvärmeanläggningar.</p> / <p>The purpose of the thesis is to identify locations in Sweden with investment opportunities considering Industrial Symbiosis. Electricity generation has to be enabled by the investment since the thesis is written on behalf of Vattenfall Generation within the Nordic Business Group. The concept of Industrial Symbiosis is used to denote collaborations regarding exchange of energy.</p><p>The lines of business using most energy are found to be most interesting to cooperate with. Companies within these lines of business are scanned in order to mark their location on a map of Sweden. The locations of certain companies in other lines of businesses are also marked on the map if the company in question uses a lot of energy. The aim of marking locations on the map is to find firms with geographic proximity offering the possibility to collaborate in the form of Industrial Symbiosis. The designs of the symbiosis and the Net Present Values of the investment opportunities found by means of this scanning are presented in this thesis.</p><p>The most interesting investment opportunities are analysed more thoroughly and two business cases are built. The analysis includes building a model of the energy system and optimizing the collaboration regarding heat between firms in the model using the program Modest.</p><p>One of the business cases concerns Grycksbo Paper in Grycksbo. The identified opportunity is investing 541 MSEK in a CHP-plant to provide Grycksbo Paper with the steam needed in their paper production. The NPV of the investment is 613 MSEK based on 10 years with an interest rate of 6 %. Similar investment opportunities are identified concerning Arctic Paper in Åsensbruk and Munkedal.</p><p>The other business case concerns Spendrups brewery and the district heating networks in Ludvika and Grängesberg. The opportunity is investing 247 MSEK in a CHP-plant in order to deliver heat to Spendrups and to the district heating networks. An investment in a connection between Ludvika and Grängesbergs district heating networks is also included in the 247 MSEK mentioned above. The NPV of the investment is – 12 MSEK based on 10 years with an interest rate of 6 %. This NPV is strongly dependent on the investment cost of the CHP-plant. Investment costs in CHP-plants have risen drastically during the last couple of years. This investment would be more profitable if the cost of CHP-plants were to fall.</p><p>Vattenfall is recommended to start discussing a collaboration regarding a CHP-plant with Grycksbo Paper and Arctic Paper. Vattenfall is also recommended to start discussing a collaboration regarding a CHP-plant with Spendrups and to observe the costs of CHP-plants in order to notice a possible decline in prices making the collaboration with Spendrups more profitable.</p>
100

Heat Transfer Correlations Between a Heated Surface and Liquid &amp; Superfluid Helium : For Better Understanding of the Thermal Stability of the Superconducting Dipole Magnets in the LHC at CERN

Lantz, Jonas January 2007 (has links)
This thesis is a study of the heat transfer correlations between a wire and liquid helium cooled to either 1.9 or 4.3 K. The wire resembles a part of a superconducting magnet used in the Large Hadron Collider (LHC) particle accelerator currently being built at CERN. The magnets are cooled to 1.9 K and using helium as a coolant is very efficient, especially at extremely low temperatures since it then becomes a superfluid with an apparent infinite thermal conductivity. The cooling of the magnet is very important, since the superconducting wires need to be thermally stable. Thermal stability means that a superconductive magnet can remain superconducting, even if a part of the magnet becomes normal conductive due to a temperature increase. This means that if heat is generated in a wire, it must be transferred to the helium by some sort of heat transfer mechanism, or along the wire or to the neighbouring wires by conduction. Since the magnets need to be superconductive for the operation of the particle accelerator, it is crucial to keep the wires cold. Therefore, it is necessary to understand the heat transfer mechanisms from the wires to the liquid helium. The scope of this thesis was to describe the heat transfer mechanisms from a heater immersed in liquid and superfluid helium. By performing both experiments and simulations, it was possible to determine properties like heat transfer correlations, critical heat flux limits, and the differences between transient and steady-state heat flow. The measured values were in good agreement with values found in literature with a few exceptions. These differences could be due to measurement errors. A numerical program was written in Matlab and it was able to simulate the experimental temperature and heat flux response with good accuracy for a given heat generation.

Page generated in 0.067 seconds