• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 140
  • 120
  • Tagged with
  • 260
  • 207
  • 173
  • 111
  • 101
  • 52
  • 47
  • 46
  • 44
  • 35
  • 34
  • 30
  • 27
  • 26
  • 25
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
61

Ytterväggars energiflexibilitet och klimatpåverkan : En jämförande studie

Christianson, Anton, Swedin, Robin January 2024 (has links)
The transition to renewable energy for heating of buildings is limited due to load peaks during the heating season which also requires fossil energy during peak hours. Increased energy flexibility by utilizing building thermal mass is considered as a cost-effective solution to this problem by storing energy from off-peak hours to be used during peak hours. This study evaluates how five different types of external walls (concrete, lightweight concrete, light expanded clay aggregate, cross laminated timber and wooden frame) enables energy flexibility by simulating the thermal autonomy for a multi-storey building depending on U-value and climate conditions in Sweden, while also considering their environmental impact from the production process through a life cycle assessment during stage A1-A3. The result shows that a concrete wall has the biggest flexible potential and wooden frame the lowest, while there is no significant difference between the rest. Considering the combination of the actual required thermal autonomy, in this case 15 hours, and environmental impact for each case, walls of cross laminated timber and wooden frame can be seen as the overall best option for southern Sweden. Despite the biggest environmental impact, concrete can be seen as the best option for northern Sweden. / Det riktas idag stort fokus på att samhället ska bli fossilfritt till 2040, därbyggsektorn är en bransch som står för en stor del av koldioxidutsläppen;uppvärmning av bostäder i Sverige utgör ca 40% av den totalaenergianvändningen. Ett sätt att öka användningen av förnybar energi föruppvärmning är att utnyttja byggnaders energiflexibilitet genom att lagravärme i byggnadens termiska massa. Syftet med denna studie är att jämföra hur fem olikaytterväggskonstruktioner (betong, lättbetong, lättklinker, KL-trä och träregel) bidrar till byggnadens energiflexibilitet samt klimatpåverkan från produktskedet A1-A3 för att avgöra hur respektive ytterväggskonstruktionlämpar sig med hänsyn till båda dessa faktorer. Dessutom studeras hur olika U-värden och geografisk placering påverkar jämförelsen. Detta görs genomatt simulera byggnadens termiska autonomi i TRNSYS då värmesystemet stängs av vid kl 6:00 på morgonen. Klimatpåverkan beräknas med Byggsektorns miljöberäkningsverktyg i termer av CO2-ekv/m2. Slutligengörs en sammanvägd jämförelse med hänsyn till både energiflexibilitet och klimatpåverkan i ett scenario där gränsvärdet för termisk autonomi är 15 timmar. Resultatet från studien visar att en yttervägg av betong är klart mestenergiflexibel i alla scenarion och en träregelyttervägg minst, medan det inte är någon betydande skillnad mellan övriga. Vad gäller påverkan av U-värdeoch geografisk placering innebär lägre U-värde och mildare klimat att effekten av större mängd termisk massa blir större, vilket innebär att energiflexibiliteten för betongytterväggen växer ytterligare i jämförelse med övriga konstruktioner. För klimatpåverkan under livscykelskedet A1-A3 innebär en betongyttervägg störst koldioxidutsläpp, medan ytterväggar av KL-trä och träregel har lägst klimatpåverkan. Vid den sammanvägda bedömningen av energiflexibilitet och klimatpåverkan med hänsyn till att flytta energianvändningen till nattid visar studien att ytterväggar av KL-träoch träregel är tillräckligt energiflexibla i södra Sverige, vilket gör de totalt sett bäst lämpade. I norra Sverige innebär dock det kallare klimatet att betongytterväggen är bäst lämpad trots störst klimatpåverkan.
62

Digital energistyrning av lägenheter - Är det lönsamt? / Digital power management of apartment houses – Is it profitable?

Lindfors, Hampus, Cedmert, Philip January 2016 (has links)
Äldre flerbostadshus i dagens Sverige använder sig av väldigt mycket energi i onödan. Uppvidingehus är ett fastighetsbolag som anser att deras flerbostadshus har en hög energianvändning. Tre områden i Åseda granskas under denna studie för att se ifall ett digitalt energistyrningssystem kan förminska energianvändningen på dessa områden. Resultatet redovisar vilka byggnader som skulle kunna uppnå en lägre energianvändning och ifall det är lönsamt för ett mindre bostadsföretag att investera i ett digitalt energistyrningssystem.
63

Energioptimering hos Freezing Food AB : Fallstudie i luftväxling och värmeöverföring

Nilsson, Dan, Magnusson Österberg, Patrik January 2017 (has links)
Arbetet handlade om att utreda energibehovet till följd av en industriport mellan ett fryslager och en utlastningsterminal, samt utreda om anläggningens golvvärme kan arbeta med sänkt temperatur för att minska uppvärmingen av fryslagret, båda delarna med syftet att identifiera energiförluster och kunna sänka energiåtgången. Energiförlusten till följd av porten identifierades genom uppmätning av luftflöden för att sedan beräknas över ett år med hjälp av en teoretisk modell. För att undersöka golvvärmens driftsparametrar gjordes en litteraturstudie för att bestämma ifall det vore tillrådligt att sänka dess arbetstemperatur. Slutsatsen blev att portens öppetvarande under år 2016 resulterade i omkring 145MWh i rent termisk energiförlust. Anläggningens vattenburna golvvärme drivs vid cirka 10-12°C vilket är enligt praxis och att en förändring av temperaturen därför inte kan rekommenderas. / This thesis was examining the energy demand due to an industrial gate dividing a freezer warehouse and it’s adjacent loading bay, as well as determining whether the facility’s sub-floor heating could be operated at a lower temperature setting in order to decrease the heat transfer into the freezer, both of which with the purpose to identify energy losses and possibly lower the total energy demand. The energy losses due to the gate were identified by measuring airflow and then calculate the loss over a whole year by means of a theoretical model. To examine the operating parameters of the sub-floor heating, a literature study was conducted in order to determine whether it would be feasible to lower its temperature. The conclusion was that the opening of the gate during year 2016 resulted in about 145MWh of purely thermal energy loss. The facility’s waterborne sub-floor heating is operated at around 10-12°C, which is according to practice, and a change of temperature cannot be recommended.
64

Klimatförändringarnas inverkan på inneklimat och energianvändning i passivhus / The impact of climate change on indoor climate and energy use in passive houses

Nylander, Joacim, Sandström, Hugo January 2016 (has links)
Purpose: The purpose of this study is to contribute with knowledge about how the warming effects of climate change may affect indoor living standards, considering that we are already living with some over-temperatures during the summer time. The specific aim is therefore to show how thermal climate in warm passive houses will be perceived, and how specific energy consumption will be affected, within the near future in southern Sweden. Method: To order to achieve the aim, a specific scenario of future temperatures had to be defined. Official climate data for the year 2050 in Gothenburg was collected and compiled. A certified passive house was theoretically exposed to the expected future climate and indoor temperature as well as energy consumption was calculated. Calculations were made using the energy calculation software BV2 for reference conditions and adaptions of both climate as well as technical solutions for greater thermal comfort. Findings: A climate scenario for Gothenburg during year 2050 illustrates that the average year-temperature increases from +7.7°C to +9.9°C. The largest change can be observed during the winter, with an increase peaking at +2.5 ºC. The results show an increase from 65 to 107 number of days during the year in which the studied passive house has an inadequate indoor temperature, as a consequence of over-temperatures. One method for thermal climate enhancing, using a combination of sun screening and air conditioning powered by solar cells, showed having good impact without considerably affecting the specific energy consumption. Implications: In a passive house without air conditioning, the thermal indoor climate will reach an unacceptable level for the tenants, more often in the year 2050, than during the reference period, due to warmer outside temperatures. The method which has the smallest impact upon the energy consumption is sun screening, while air conditioning is the most effective, but also very energy consuming. In order to optimally conserve the thermal indoor climate without decreasing the free energy during the winter, one should install both sun screening and air conditioning in their passive house. Limitations: The result is applicable on passive houses within climate zone III, but the general conclusions made applies for all passive houses in Sweden. Using different methods of calculating the indoor temperature may result in variable results. Keywords: Climate change, Passive house, Indoor climate, Thermal comfort, Energy consumption
65

Åtgärdsförslag till Gävle Kommun för omhändertagandet av den förorenade marken på Brynäs 19:7, år 2015

Hansen, Erik, Norling, Susanne January 2015 (has links)
År 2010 fanns enligt Länsstyrelsen (2011) 80 000 platser som misstänktes vara förorenad och har uppskattats kosta 45 miljarder kronor att åtgärda och ta 40 år. Fastigheten Brynäs 19:7 i Gävle, där Cloetta och tidigare verksamheter har bedrivits, är förorenad med bland annat PAH, PCB, metaller och petroleumkolväten. Fastigheten ska bli ett bostadsområde men behöver först genomgå någon typ av saneringsåtgärd. För att välja den mest hållbara saneringstekniken är multikriterieanalys (MKA) ett bra verktyg. Inom MKA finns nu SCORE som är specifikt framtagen för förorenad mark, efterbehandling och beslutsfattande. Syftet med detta arbete är att ta fram åtgärdsförslag åt Gävle kommun för omhändertagandet av förorenad mark på Brynäsområdet 19:7. Målsättningen är att utreda för lämpliga efterbehandlingsmetoder och välja den bästa genom en utförd MKA. Under kapitlet Metod beskrivs hur studien kom till, tillvägagångssättet för litteraturundersökningen och MKA:n, samt viktiga val. Litteraturundersökningen består av information om Brynäs 19:7, bland annat om föroreningssituationen och en allmän områdesbeskrivning. Sedan följer en litteraturundersökning om de valda efterbehandlingsmetoderna; Biosan, Bioreaktor, Daramend, Jordtvätt, Termisk behandling och Vakuum extraktion. Biosan, Bioreaktor och Daramend är biologiska metoder och jordtvätt en fysikalisk metod. Efterbehandlingsmetoderna innehåller främst en processbeskrivning, typ av föroreningar den kan behandla och reningsgraden. Resultatet har sammanställts i ett antal stapeldiagram, varav samtliga presenteras ur ett hållbarhetsperspektiv där alla tre hållbarhetsdomäner har inkluderats. Det har framgått från resultatet att Vakuum extraktion är det mest hållbara alternativet. Diskussionen innefattar bland annat problemen kring fyllnadsmassorna på området, Off-site kriterier och resultatet. Slutsatsen är Vakuum extraktion är den mest hållbara av alternativen vid en sanering av fastigheten Brynäs 19:7 och det rekommenderas att metoden används, alternativt termisk behandling. Metoderna skulle även kunna kombineras för att minska deras svagheter och få en effektiv rening av de föroreningar som kräver sanering. De begränsningar som funnits har främst varit tidsbrist på grund av den omfattande multikriterieanalysen. Brist på information om Brynäs 19:7 och om de olika saneringsteknikerna har även till viss del varit en begränsande faktor. / In 2010, there was according to the County Administrative Board (2011) 80 000 sites suspected of being contaminated, and has been estimated to cost 45 billion to fix and take 40 years. The property Brynäs 19:7 in Gävle, where Cloetta and past operations have been conducted, is contaminated with mostly PAHs, PCBs, metals and petroleum hydrocarbons. The property will be a residential area but need to first undergo some type of remediation action. In order to choose the most sustainable remediation technology, a multi-criteria analysis (MCA) is a fitting tool to use. Within MCA is now SCORE, a specifically designed program for contaminated land, remediation and decision making. The purpose of this work is to develop and present proposals for actions to take to Gävle municipality, for disposal of contaminated soil at Brynäs 19:7. The goal is to determine the appropriate treatment methods and choose the best one by doing an MCA. In the methodology chapter it is described how the study came to be, the approach of the literature review, the MCA and important choices. The literature review consists of information on Brynäs 19: 7, including the pollution situation and a general description of the area. Then follows a literature review on the selected remediation methods; BioSan, Bioreactor, Daramend, Soil Washing, Thermal processing and Vacuum extraction. BioSan, Bioreactor and Daramend are biological methods, and soil washing a physical method. The remediation methods mainly contain a process description, type of pollution it can process and purification degree. The results have been compiled in a number of bar graphs, all of which are presented from a sustainability perspective, where all three sustainability domains have been included. The result shows that Vacuum extraction is the most viable option. The discussion includes the problems surrounding the filling material of the area, Off-site criteria and results. The conclusion is that the Vacuum extraction is the most sustainable of the alternatives to a clean-up of the property Brynäs 19: 7 and it is recommended that the method is used, alternatively Thermal processing. The methods could be combined to reduce their weaknesses and get an effective removal of the contaminants that require remediation. The limitations that existed have been mainly lack of time because of the extensive MCA. Lack of some information on Brynäs 19: 7 and about the various remediation techniques have to some extent been a limiting factor.
66

Termisk bindning av UHMWPE och smältfiber i nonwoven för waterjetskydd : Ett alternativ till kemisk doppning?

Majuri, Tiina, Linder, Annika January 2016 (has links)
Inom området skyddskläder för utövande av vattenblästring ställs mycket höga krav på säkerhet, de textila material och tillverkningstekniker som används idag ger stela produkter med negativ hälso- och miljöpåverkan vid produktion och är en tidskrävande tillverkningsprocess. Ämnesområdet med en vara av nonwoven som skyddande komponent i skyddskläder vilken sammanfogas med hjälp av en smältfiber har undersökts tidigare i en kort förberedande studie vilket lagt grund för detta examensarbete. Uppdraget om en alternativ tillverkningsmetod till skyddande komponent till en skyddsdräkt för vattenblästring kommer från företaget TST Sweden AB i Kinna. En nonwovenprodukt kan ge ett mjukt och mer följsamt resultat på varan och är relativt kostnadseffektiv att tillverka. De fibertyper som är intressanta för denna kombination är UHMWPE-fiber och bikomponentsfiber. UHMWPE-fibern har tidigare visat klara kraven på säkerhet och bikomponentsfibern fungerar som smältfiber för att skapa bindepunkter i nonwovenvaran. Denna studie undersöker och jämför ett material som tas fram i studien med syfte att klara samma skyddande egenskaper som ett referensmaterial av den produkt som används idag. Målet är att ersätta den kemiska doppningen med en termisk sammanfogning. Studien är både teoretisk och praktisk och går igenom hela processen från kardning till termiska bindesätt och slutligen även för materialegenskapstester genom bland annat dragprovning och penetrationstester. Två olika bikomponenter jämfördes i denna studie, på grund av bristande mottagningskontroll på den beställda bikompPE-fibern tillverkades material utifrån fel specifikationer, vid upptäckt av detta adderades anpassade tillverkningsmetoder. Resultatet från denna studie tyder på att en komponent till skyddsdräkt för vattenblästring tillverkad av UHMWPE/bikomp – nonwoven har kommit framåt i utvecklingen men ännu inte är färdigutvecklad. Studien visar att provserien av nonwoven som bestod av 70% UHMWPE och 30% coPES/PES vilken behandlades termiskt i mikrovågsugn visade bäst resultat i energiabsorption, men vilket inte nådde upp till samma nivå som referensmaterialet. Med avseende på materialets styvhet nåddes klara förbättringar då alla provserier uppvisade mjukare resultat än referensmaterialet. Hållbarhetsmässigt ses fördelar med nonwoven-konstruktion av lågsmältande bikomponentsfiber jämfört med kemiskt doppad nonwoven.
67

Jämförelse av VAV- och CAV-ventilationssystem för nybyggd skola och dess känslighet för ökad personbelastning : En simuleringsstudie med IDA ICE

Hansson, Kajsa January 2019 (has links)
Att minska energianvändningen är lika mycket ett globalt mål som ett nationellt mål. Sverige har som mål att öka effektiviseringen av energianvändningen med 20 % fram till år 2020. Det gör att nästan alla sektorer påverkas och inte minst bostads- och servicesektorn som står för nästan 40 % av Sveriges energianvändning. Ventilationssystem är en av de saker som kan bidra till energibesparingen. I den här studien har en nybyggd grundskola simulerats avseende energi och komfort där olika ventilationssystem testats för att se vilket system som är mest lönsamt ekonomiskt, energi- och komfortmässigt. Det som skiljer ventilationssystemen åt är de olika typerna av flödesreglering. Två huvudtyper av ventilationsflödesreglering har testats: ”Variable Air Volume” = Luftflödet varierar efter behovet (VAV) och ”Constant Air Volume” = Konstant luftflöde (CAV). Byggnaden, som är välisolerad och har tung stomme, har även simulerats med ökad personbelastning för att se hur det påverkar ventilationssystemet. Metoden som används för att utföra arbetet är en simuleringsstudie av komparativt slag, där datorprogrammet IDA ICE 4.8 har använts för att modellera byggnaden och utföra simuleringarna. Modellen som har simulerats efterliknar delar av grundskolan Stigslundsskolan i Gävle, i både uppbyggnad, ventilation och användningsgrad. Data har samlats in från konsultföretaget Rambolls databaser med information om projekteringen av skolan och genom personlig kommunikation. Simuleringen av ett skolår har utförts och ett schema för personbelastningen har ställts in för varje sal för att efterlikna det schema som eleverna går efter i dagsläget. Resultatet av simuleringarna visade att VAV -ventilationssystemet som efterliknar det projekterade fallet väl täckte ventilationsbehovet, använde mindre energi än CAV-systemet och skapade ett mycket bra termiskt klimat i byggnaden. Resultatet visade också att ökad personbelastning hade stor inverkan på ventilationssystemet, och medförde bland annat att återbetalningstiden för VAV-systemet ökade från 11 till 30 år. / To reduce the energy use is as much a global goal as it is an international goal. The Swedish goal is to increase the efficiency of energy use with 20 % by year 2020. This means that almost all the sectors are affected, that includes the housing and service sector which accounts for almost 40 % of Sweden’s energy use. The ventilation system is one thing that can contribute to saving energy. In this study a new built primary school has been simulated, regarding energy use and thermal comfort, where different ventilation system has been tested to determine which system are the most profitable in economically, energy and comfortably. The ventilation system different in the flow control. Two main types of flow control have been tested: Variable Air Volume (VAV) and Constant Air Volume (CAV). The building, which is well insulated and has a heavy body has also been simulated with increased personal load to see how it affects the ventilation system. The method used to perform the work is a comparative type simulation study. The computer program IDA ICE 4.8 has been used to build the model and do the simulations. The model that has been simulated resemble the primary school Stigslundsskolan in Gävle in both construction, ventilation and degree of use. Data has been collected from the consulting company Ramboll’s database with information on the planning of the school. Personal communication has also been used to collect information. The simulations have been performed for a school year and a schedule for the personal load has been set for each hall to imitate the schedule that the students are following today. The result of the simulations showed that the VAV ventilation system, which resemble the planned case, cover the ventilation requirements, uses less energy than the CAV system and create a very good thermal climate in the building. The result also shows that the increased personal load had a great influence on the VAV ventilation system and increased the repayment period from 11 to 30 years.
68

Textila aktuatorer

SVENSSON, JENNIFER, KRALJ, CAROLINE January 2014 (has links)
Aktuatorer är idag det senaste inom smarta textilier efter utvecklingen av bland annat sensorer. Med aktuatorernas funktioner finns idag potential att utveckla nya material som inte bara har förmågan att känna av saker, utan även röra sig genom formförändring. Formändringen innebär att aktuatorer har förmåga att ge en respons på stimulus och en del aktuatorer har dessutom förmågan att uppnå reversibilitet. I detta examensarbete presenteras därmed en experimentell studie där olika polymera material har sammanfogats genom laminering och därefter utsatts för värme. Syftet med den experimentella studien är bland annat att undersöka om plastlamineringar kan efterlikna termiskt aktiverade bikomponentfibrer. Resultatet av den experimentella studien tyder på att olika kombinationer av polymera material kan erhålla både respons och reversibilitet genom påverkan av termisk stimulus. Vidare har ett samarbete med en forskningsgrupp vid Linköpings Universitet inletts för att tillsammans bidra med utveckling av textila aktuatorer. Därmed har textila konstruktioner tagits fram på en handstickmaskin samt en elektronisk flatstickmaskin. Samtliga konstruktioner har framställts i olika material samt varierande bindningar och dessa erhöll bra elasticitet, vilket för syftet hade stor betydelse. Konstruktionerna blev därefter belagda med en elektroaktiv polymerbeläggning för att konstruktionerna skulle bli elektriskt ledande och utsattes sedan för elektrisk spänning för att uppnå önskad rörelse. Resultatet visade dock att rörelse inte kunde uppnås hos de konstruktioner som hann testas under projektets gång. Avsikten med detta samarbete är att utveckla textila aktuatorer som i sin tur kan efterlikna naturliga muskler. Således är förhoppningarna att bidra till utvecklingen av framtidens artificiella muskler. / Program: Textilingenjörsutbildningen
69

CFD Measurements of the Cooling Air in a DC-Motor

Amanatidou, Rebeka January 2008 (has links)
<p> </p><p>The cooling system of a DC-motor is examined in this thesis. A change of direction of the cooling air is desired to prevent the generated coal dust from entering into the windings of the machine. Ultimately this will have a negative effect on the cooling in the machine and the loss of cooling needs to be compensated through other ways. The purpose of this thesis is to work for an improved operational safety and performance of the DC-motor and to make it more competitive in the market. By modelling the interior geometry of the machine and defining the boundaries in the software programs Gambit and FLUENT respectively, the motion and the heat transfer of the airflow could be simulated. The simulation results would give us an understanding of the flow pattern which later could be used to develop design modifications on the cooling system of a DC-motor. In this thesis the main focus lies on creating a simulation model with a sufficiently fine mesh size.</p>
70

Metod för analys av elförbrukning i hushåll

Walde, Fredrik January 2009 (has links)
No description available.

Page generated in 0.0327 seconds