• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2279
  • 56
  • 33
  • 14
  • 14
  • 13
  • 12
  • 9
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • Tagged with
  • 2399
  • 1188
  • 410
  • 401
  • 320
  • 269
  • 247
  • 180
  • 173
  • 151
  • 134
  • 129
  • 119
  • 118
  • 110
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
461

Modelos inar sazonais e de raízes unitárias

PEREIRA, Marcelo Bourguignon 31 January 2011 (has links)
Made available in DSpace on 2014-06-12T18:03:18Z (GMT). No. of bitstreams: 2 arquivo622_1.pdf: 870449 bytes, checksum: 76110de8baadc7763ba367932fb15aba (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2011 / Conselho Nacional de Desenvolvimento Científico e Tecnológico / Séries temporais de contagem têm chamado a atenção pela importância em aplicações nas diversas áreas de conhecimento. Os processos estocásticos usuais assumem que as marginais são contínuas e, em geral, não são adequados para modelar séries de contagem. Portanto, surge a necessidade de investigar metodologias apropriadas para séries temporais com distribuições marginais discretas. Em particular, o estudo da presença de raízes unitárias e o comportamento sazonal do processo de valores inteiros motivam uma vertente de pesquisa de grande interesse para aplicações práticas e são os principais objetivos desta pesquisa. Nesse contexto, apresentamos o teste de Dikey & Fuller (1979) e verificamos o comportamento do teste, através de ensaios de Monte Carlo, em processos autorregressivos de valores inteiros de ordem um, quando o processo apresenta raiz unitária. Os pontos críticos empíricos da estatística de teste do teste de Dickey-Fuller, para vários valores do percentil α, são calculados quando o teste é utilizado em processos INAR(1) com erros Poisson, para diversos valores do parâmetro λ. Comparações entre a utilização do teste de Dickey-Fuller em processos com marginais contínuas e discretas também são abordadas. No que tange à sazonalidade em processos de contagem, é proposto um modelo de valores inteiros com estrutura sazonal baseado no modelo de Al-Osh & Alzaid (1987). As principais propriedades do modelo proposto são derivadas, tais como os momentos, a função de autocovariância e a função de autocorrelação. Ensaios de Monte Carlo são realizados para comparar os vícios e erros quadráticos médios de três estimadores para os parâmetros do modelo proposto. Como motivação do uso da metodologia sugerida, a série do índice da qualidade do ar da cidade de Cariacica-ES foi analisada
462

Verossimilhança perfilada nos modelos não lineares simétricos heteroscedásticos

Correia de Araújo, Mariana 31 January 2012 (has links)
Made available in DSpace on 2014-06-12T18:06:36Z (GMT). No. of bitstreams: 2 arquivo9498_1.pdf: 801043 bytes, checksum: ccc5adc29d401845fe6ebd6adf82f473 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2012 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Nesta dissertação abordamos o desempenho do teste da razão de verossimilhanças usual e suas versões modificadas em pequenas amostras na classe dos modelos não lineares simétricos heteroscedásticos (MNLSH), mais especificamente, nos modelos t􀀀Student com 4 graus de liberdade e Exponencial potência com parâmetro de forma k = 0; 3. Além do teste usual, são considerados os testes baseados na estatística da razão de verossimilhanças corrigida via Bartlett (1937), LR, na estatística da razão de verossimilhanças perfiladas modificadas via Cox e Reid (1987), LRm; e sua respectiva versão corrigida via DiCiccio e Stern (1994), LRm. Desse modo, os objetivos principais deste trabalho são obter um fator de correção de Bartlett para a estatística LRm na classe dos MNLSH e realizar um estudo de simulação para avaliar o desempenhos dos testes de hipóteses baseados na estatística da razão de verossimilhanças usual, LR, e nas estatísticas LR, LRm e LRm . Neste estudo de simulação avaliamos o comportamento dos quatro testes em questão com relação ao tamanho, poder e discrepância relativa de quantis em amostras de tamanhos finitos e pode-se observar que, de modo geral, o teste baseado na estatística LRm apresentou o melhor desempenho
463

Avaliação da cinemática da caixa torácica de crianças com doenças neuromusculares através de pletismografia óptico eletrônica

FERREIRA FILHO, Antônio Francisco de Andrade 31 January 2011 (has links)
Made available in DSpace on 2014-06-12T23:13:24Z (GMT). No. of bitstreams: 2 arquivo6714_1.pdf: 691580 bytes, checksum: eda6b7f2725ca1730c7048ec9a5a24d7 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2011 / Resumo: Introdução: A deterioração da função respiratória é uma das principais causas da mortalidade dos pacientes com Doenças Neuromusculares (DNM). As alterações da força e do tônus muscular causam progressiva perda de força muscular periférica e respiratória, que determinam hipoventilação alveolar. Testes convencionais de função pulmonar e de avaliação da musculatura respiratória necessitam de cooperação e em crianças menores de seis anos não se obtém a acurácia desejada. Um método acurado para estimar o volume absoluto e com boa discriminação de suas variações durante a respiração é a Pletismografia Óptica Eletrônica (POE). Objetivo: O nosso estudo teve o objetivo de avaliar a capacidade do POE em mensurar alterações da cinemática da caixa torácica de crianças menores de seis anos portadoras de DNM. Métodos: Foi realizado um estudo de série de casos, onde participaram do estudo crianças na faixa etária de um a seis anos de idade, com DNM diagnosticadas previamente pelo neuropediatra assistente. Resultados: Houve uma taxa de aproveitamento de 75% na posição supina e 83,3% na posição sentada das avaliações. A mudança de posição de sentada para supino acarretou queda do volume pulmonar de 22,1%. Três pacientes apresentaram assicronia importante entre os compartimentos da caixa torácica. Conclusão: a POE demonstrou ser uma técnica útil para analisar a função respiratória de crianças menores de seis anos de idade com DNM, gerando dados que podem identificar o inicio de sobrecargas a função respiratória, como a assicronia entre os compartimentos e a queda do volume pulmonar com a variação da posição de sentado para supino
464

Reconstrução Tomográfica com superfícies B-splines

Ferreira de Oliveira, Eric 31 January 2011 (has links)
Made available in DSpace on 2014-06-12T23:14:42Z (GMT). No. of bitstreams: 2 arquivo2690_1.pdf: 6789118 bytes, checksum: 05cc3d356f57a760866a4fc16453b6e0 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2011 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Vários estudos têm indicado que, das várias classes de algoritmos de reconstrução aplicáveis para dados limitados, os baseados na técnica de reconstrução algébrica são mais flexíveis e precisos. Infelizmente, estas técnicas, geralmente, sofrem de ruídos ocasionados por processos de correção durante a reconstrução e também por inconsistências nos dados adquiridos pelos tomógrafos. O pós - processamento da imagem reconstruída com a aplicação de filtros pode ser feito para atenuar a presença de ruídos, mas geralmente atenuam também as descontinuidades presentes em bordas que distinguem objetos ou falhas. O presente trabalho propõe a redução de ruídos assegurando a continuidade (das derivadas) da superfície antes da reconstrução, representando cada incógnita por uma combinação linear de pontos de controle e suas bases B-splines. São aplicadas três bases Bsplines: B1 , B2 e B3, assegurando as continuidade C0, C1 e C2, respectivamente. Para validação da técnica, foram utilizadas simulações de modelos propostos na literatura e medidas experimentais por tomografia gama. Os resultados foram comparados com as técnicas algébricas ART, SIRT, MART e SMART, sendo validada satisfatoriamente para todos os phantoms propostos. Todas as bases B-splines aplicadas obtiveram erros menores que as técnicas de correção ART e SIRT, sendo a B3, a de melhor desempenho. Este resultado pode ser explicado pelas restrições de suavidade impostas à superfície reconstruída pelas bases Bsplines e a inclinação das técnicas aditivas a ruídos, principalmente para um número limitado de dados (5 e 10 vistas). A performance das técnicas multiplicativas para essa situação é a melhor, mostrando uma imagem sem artefatos e com pouco ruído. Devido a esse fato, a técnica b-spline não tem bons resultados, apresentando na maioria dos casos, erros maiores. Para todos os testes realizados, as técnicas de representação B-splines superaram os filtros de mesma natureza aplicados no pós-processamento, sugerindo que a técnica seja utilizada no lugar da filtragem pós-processamento
465

VEROSSIMILHANÇA PERFILADA NOS MODELOS NÃO LINEARES SIMÉTRICOS HETEROSCEDÁSTICOS

ARAÚJO, Mariana Correia de 02 1900 (has links)
Submitted by Etelvina Domingos (etelvina.domingos@ufpe.br) on 2015-03-05T17:58:21Z No. of bitstreams: 2 MA.pdf: 801043 bytes, checksum: ccc5adc29d401845fe6ebd6adf82f473 (MD5) license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) / Made available in DSpace on 2015-03-05T17:58:21Z (GMT). No. of bitstreams: 2 MA.pdf: 801043 bytes, checksum: ccc5adc29d401845fe6ebd6adf82f473 (MD5) license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Previous issue date: 2012-02 / CAPES / Nesta dissertação abordamos o desempenho do teste da razão de verossimilhanças usual e suas versões modificadas em pequenas amostras na classe dos modelos não lineares simétricos heteroscedásticos (MNLSH), mais especificamente, nos modelos tStudent com 4 graus de liberdade e Exponencial potência com parâmetro de forma k = 0; 3. Além do teste usual, são considerados os testes baseados na estatística da razão de verossimilhanças corrigida via Bartlett (1937), LR , na estatística da razão de verossimilhanças perfiladas modificadas via Cox e Reid (1987), LRm; e sua respectiva versão corrigida via DiCiccio e Stern (1994), LR m . Desse modo, os objetivos principais deste trabalho são obter um fator de correção de Bartlett para a estatística LRm na classe dos MNLSH e realizar um estudo de simulação para avaliar o desempenhos dos testes de hipóteses baseados na estatística da razão de verossimilhanças usual, LR, e nas estatísticas LR , LRm e LR m . Neste estudo de simulação avaliamos o comportamento dos quatro testes em questão com relação ao tamanho, poder e discrepância relativa de quantis em amostras de tamanhos finitos e pode-se observar que, de modo geral, o teste baseado na estatística LR m apresentou o melhor desempenho.
466

Avaliação de função pulmonar e aptidão cardiorrespiratória em mulheres obesas e portadoras de apneia obstrutiva do sono no climatério

PASSOS, Vívian Maria Moraes 16 March 2012 (has links)
Submitted by Heitor Rapela Medeiros (heitor.rapela@ufpe.br) on 2015-03-05T18:34:23Z No. of bitstreams: 2 vmmp.pdf: 1942127 bytes, checksum: bde91cf033e8764ed7ab65c31d428080 (MD5) license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) / Made available in DSpace on 2015-03-05T18:34:23Z (GMT). No. of bitstreams: 2 vmmp.pdf: 1942127 bytes, checksum: bde91cf033e8764ed7ab65c31d428080 (MD5) license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Previous issue date: 2012-03-16 / Mulheres no climatério têm maior predisposição a desenvolver apneia obstrutiva do sono (AOS), distúrbio respiratório que pode acarretar prejuízos na função pulmonar e redução da tolerância aos esforços, além de ser capaz de promover alterações peculiares sobre variáveis cardiovasculares desde o repouso até o exercício. Objetivos: Avaliar, em mulheres no climatério, as repercussões da obesidade e da AOS sobre função pulmonar, distância máxima percorrida no teste de caminhada de 6 minutos (TC6M) e comportamento dos parâmetros respiratórios e cardiovasculares antes e após submissão ao teste de esforço submáximo. Métodos: Estudo descritivo analítico, tipo corte transversal, em que foram avaliadas 40 mulheres com idade entre 45 e 60 anos (Idade=51,4anos ± 5,2anos), sedentárias e sem história de fumo há no mínimo um ano, submetidas previamente à polissonografia. As participantes foram divididas em 4 grupos: Eutróficas sem AOS (IMC=22,77 ± 1,99kg/m2), Eutróficas com AOS (IMC=22,06 ± 2,40kg/m2), Obesas sem AOS (IMC=33,88 ± 3,09kg/m2) e Obesas com AOS (IMC=34,01 ± 1,79kg/m2). Todas passaram por avaliação clínica e antropométrica, seguida de testes de função pulmonar e TC6M. Resultados: Índice apneia-hipopneia (IAH) foi diferente entre grupos, sendo maior em mulheres eutróficas com AOS (IAH=8,94 ± 2,93eventos/hora) quando comparadas a eutróficas sem AOS (IAH=1,78 ± 1,48eventos/hora) e maior em obesas com AOS (IAH=17,98 ± 10,73eventos/hora) quando comparadas a eutróficas, com ou sem AOS, e quando comparadas a obesas sem AOS (IAH=2,33 ± 1,74eventos/hora) (p<0,05). O índice de qualidade do sono de Pittsburgh (IQSP) foi menor em obesas sem AOS (IQSP=6,17 ± 2,48) ao ser comparado ao de eutróficas sem AOS e com AOS (IQSP=9,08 ± 3,04 e 9,80 ± 3,63, respectivamente) e ao ser comparado aos valores de obesas com AOS (IQSP=9,73 ± 3,53) (p<0,05). Quanto às variáveis de função pulmonar, apenas o percentual do predito da relação entre volume expiratório forçado no primeiro segundo e capacidade vital forçada foi maior no grupo de obesas com AOS, quando comparadas a eutróficas com AOS (%pred VEF1/CVF=105,73 ± 5,73 vs. 97,60 ± 6,07, respectivamente; p<0,05). A distância máxima percorrida no TC6M não diferiu entre grupos. Em relação às variáveis respiratórias e cardiovasculares no repouso, saturação periférica de oxigênio foi menor em obesas com AOS comparadas a eutróficas com AOS (SpO2=97,47 ± 1,46% vs. 98,60 ± 0,55%, respectivamente). Mulheres obesas com AOS apresentaram níveis de pressão arterial sistólica maiores do que eutróficas com e sem esse distúrbio (PAS=136,53 ± 18,37mmHg vs. 110,20 ± 18,28mmHg e PAS=136,53 ± 18,37mmHg vs 124,31 ± 9,60mmHg, respectivamente; p<0,05). A pressão arterial diastólica em obesas com AOS foi maior quando comparada a eutróficas sem AOS (PAD=89,67 ± 7,70mmHg vs. 81,31 ± 8,50mmHg; p<0,05). Durante a recuperação, a frequência cardíaca foi maior em obesas com AOS (FC=77,0 ± 9,05bpm) quando comparadas eutróficas sem AOS (FC=74,33 ± 7,88bpm) (p<0,05). As demais variáveis cardiorrespiratórias não foram diferentes entre grupos. A análise intragrupos mostrou que em mulheres eutróficas sem AOS houve incremento significativo de frequência respiratória (FR) (14,92 ± 3,71ipm vs. 17,23 ± 2,80ipm; p=0,011) e de PAD (81,31 ± 8,50mmHg vs. 85,46 ± 10,22mmHg; p=0,029), em eutróficas com AOS houve aumento de PAS (110,20 ± 18,28mmHg vs. 131,60 ± 20,02mmHg; p=0,043) e, em obesas com AOS, observou-se aumento tanto de FC (71,40 ± 7,94bpm vs. 77,0 ± 9,05bpm; p=0,010) quanto de FR (18,40 ± 5,28ipm vs. 20,80 ± 4,07ipm; p=0,032). Outras variáveis não se modificaram do repouso até a recuperação do exercício intragrupos, assim como não houve diferenças no grupo de obesas sem AOS. Conclusão: De acordo com os resultados deste estudo, sugere-se que em mulheres obesas no climatério a AOS não provoca maiores prejuízos sobre função pulmonar e distância percorrida no TC6M. Nessa população, a AOS isoladamente influenciou os parâmetros cardiorrespiratórios no repouso, mas não na recuperação do exercício, e ficou demonstrado que a obesidade foi fator contribuinte para potencializar as alterações ocorridas, especialmente no repouso.
467

[en] CLINICALLY VALIDATING A BATTERY COGNITIVE SCREENING BRIEF (BCSB) FOR EARLY DIAGNOSIS OF DEMENTIA IN ELDERLY ADULTS IN A GERIATRIC CLINIC OF A PUBLIC HOSPITAL / [pt] VALIDAÇÃO CLÍNICA DE UMA BATERIA BREVE DE RASTREIO COGNITIVO (BBRC) PARA DIAGNÓSTICO PRECOCE DE DEMÊNCIA DE ALZHEIMER EM CLÍNICA GERIÁTRICA DE HOSPITAL PÚBLICO

CRISTINA VIEIRA MIRANDA 06 February 2017 (has links)
[pt] É um grande desafio, diagnosticar precocemente sinais da doença de Alzheimer. Existem diversos testes de rastreio usados para o diagnóstico de demência, porém sofrem influencias da idade e escolaridade do paciente, o que justifica a validação de ais instrumentos à realidade cultural do país. O presente estudo teve como objetivo, a validação clínica de uma bateria breve de rastreio cognitivo (BBRC) para diagnóstico precoce de demência de Alzheimer de idosos atendidos no ambulatório de geriatria de um hospital público. Métodos: Foram investigados 51 idosos com DA provável (idade média 81.3 (5.7); escolaridade 3.7 (2.8)) e 123 idosos sem demência (idade média 78.6 (7.3); escolaridade 4.7 (3.5)). O desempenho entre os grupos foi comparado utilizando metodologia quantitativa. Os pontos de corte para cada variável foram gerados pela análise das curvas ROC. Resultados: Não houve diferenças significativas entre os grupos nas variáveis escolaridade e gênero, mas houve em relação à idade (p igual 0,01). Participantes com DA provável obtiveram desempenho significativamente pior em todos os testes cognitivos (p menor 0,05) em relação aos sem demência. O grupo com DA apresentou prejuízo pela escala Lawton, no autorrelato e informante (p menor 0,01 e p igual 0,01), porém não foi significativo na escala índice de Katz (p maior 0,01). As análises ROC indicaram que as medidas de memória foram as mais sensíveis para discriminar os grupos. Conclusão: A BBRC foi precisa na identificação de idosos com DA em um ambulatório de geriatria em um hospital federal a partir de uma amostra com fragilidade clínica e cognitiva. / [en] Diagnosing the early signs of the disease is a major challenge. There are several screening tests used for the diagnosis of dementia., but these tests are influenced by a patient s age and educational level, which justifies the need for research that validates such instruments conforming them to the cultural reality of the country . The present study aimed at, clinically validating a battery cognitive screening brief (BCSB) for early diagnosis of dementia in elderly adults in a geriatric clinic of a public hospital. Methods: 51 elderly adults with a clinical diagnosis of probable Alzheimer s disease ( mean age 81.3 (5.7) ; education 3.7 (2.8) ) and 123 older adults without dementia ( mean age 78.6(7.3) ; education 4.7( 3.5) ) were assessed. Test performance was compared between groups and data was analyzed through a quantitative method . The cut off points for each variable were generated by a ROC analysis . Results: There were no significant differences between groups with respect to education and gender, but there was a difference with respect to age (p equal 0,01). People with DA scored significantly lower on all cognitive tests ( p any less 0.05, for all tests ) . The group with AD showed deficits in the Lawton scale, both as self-reported by the informant (p any less 0.01 and p equal 0.01). The loss was not significant in the range of basic activities Katz (p more 0.01). The results of the ROC analyses indicated that measures of memory were the most sensitive measures to discriminate between individuals with AD and controls. Conclusion : The BCSB was accurate in identifying people with AD in a geriatric outpatient clinic at a federal hospital, in a sample with clinical and cognitive frailty.
468

Percepção de esforço em exercício sob fadiga em normóxia e hipóxia / Perceived exertion in fatiguing exercise in normoxia and hypoxia

Fontes, Eduardo Bodnariuc, 1979- 18 August 2018 (has links)
Orientador: Antonio Carlos de Moraes / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Educação Física / Made available in DSpace on 2018-08-18T17:14:16Z (GMT). No. of bitstreams: 1 Fontes_EduardoBodnariuc_D.pdf: 9503115 bytes, checksum: ace5f37f3ad02cc8337e62c4be60c8b2 (MD5) Previous issue date: 2011 / Resumo: O presente trabalho buscou um maior entendimento da formação da percepção subjetiva de esforço (PSE) durante esforços exaustivos. Dessa forma, o primeiro estudo verificou as associações da atividade muscular (EMG) com a PSE, bem como a determinação do limiar de esforço percebido (LEP) e de fadiga neuromuscular (LFN). Esse estudo analisou 11 adultos jovens durante testes de carga constante até a exaustão voluntária máxima com monitoramento constante de PSE e EMG. A taxa de aumento dessas variáveis (EMGslope e PSEslope) foram significativamente correlacionados e inversamente associados ao tempo de exaustão. LEP e LFN e não se diferiram significativamente. Assim, indicamos a estreita relação do recrutamento adicional de fibras com o aumento da PSE. O segundo estudo foi realizado durante estágio no exterior (sanduíche) na África do Sul no ano de 2009. Nesse trabalho, foi analisado os efeitos da diminuição de oferta de oxigênio (hipóxia) sobre variáveis centrais e periféricas e suas associações com PSE. Seis ciclistas realizaram testes exaustivos de carga constante em normoxia e hipóxia com contínua aquisição de respostas de PSE, EMG e oxigenação muscular (MOX) e cerebral (COX). Foi demonstrado que na condição hipóxia ocorre um significativo aumento sobre PSE em seus diferentes modos (local, respiração e geral), EMG e COX, mas não em MOX. Os slopes de PSE e valores finais de COX foram relacionados ao desempenho em normóxia, no entanto ainda maiores foram apresentados em hipóxia. Além disso, COX foi ainda significativamente relacionada RPE local em normóxia e novamente, hipóxia exerceu efeitos maiores nessas associações, mas dessa vez para todos os modos de PSE. No terceiro estudo, foram utilizado os mesmos dados do estudo anterior para verificamos os possíveis efeitos de hipóxia ao estimarmos LEP de maneira diferenciada (local, respiração e geral) e LFN pelo mesmo protocolo. Todos os modos de LEP diminuíram significativamente sob hipóxia, com maiores efeitos sobre LEP local. Já LFN não respondeu aos efeitos da condição experimental. Dessa forma, expandiu-se a utilização de LEP para altitudes moderadas e foi apresentado uma nova forma de predizer capacidade aeróbia referente aos membros envolvidos e respiração, além de PET para o corpo como um todo. Associando os achados dos estudos, podemos inferir a estreita relação de respostas periféricas e centrais sobre a formação de PSE, senda essas fortalecidas em condições de diminuídas ofertas de oxigênio. Mais adiante, essas associações justificam a ampliação de utilização prática de PSE, podendo ser para o exercício de alta intensidade ou monitoramento localizado da capacidade aeróbia / Abstract: The present study aimed to bring better understanding of ratings of perceived exertion (RPE) during exhaustive exercise. Thus, the first study verified the associations of the neuromuscular responses (EMG) with RPE, as well as the determination of the perceived exertion threshold (PET) and neuromuscular fatigue threshold (NFT). Eleven adults performed exhaustive constant-load tests with RPE and EMG recordings. The rate of increase of these variables (EMGslope e RPEslope) were significantly related and associated to performance. Além disso, PET and NFT did not differed. Therefore, it was shown the close relationship of the additional muscle recruitment and RPE. The second study was completed during the international internship in South Africa in 2009. At this investigation, were demonstrated the effects of decreased fraction of inspired oxygen (hypoxia) on central and peripheral responses, as well their relationship with RPE. Six trained cyclists completed exhaustive constant-load tests under normoxia and hypoxia having continuously monitoring of RPE, EMG and cerebral (COX) and muscle (MOX) oxygenation. It was shown that under hypoxia there is a significant increase for all RPE modes (legs, breathing and overall), EMG and COX, but not MOX. The RPE slopes and end values for COX were related to performance under normoxia, however higher associations were found under hypoxia. In addition, COX was significantly related to RPE for legs under normoxia, but again, hypoxia exert higher effects on this association, but this time to all RPE modes. During the third study, the data from last investigation was used to verify the possible effects of hypoxia when estimating differentiated PET (legs, breathing and overall) and NFT during same protocol. All PET modes decrease significantly under hypoxia, with higher effects of PET legs, however, NFT estimation was not affects by this experimental condition. Thus, PET's used was expanded to moderated altitudes and presented a new method to predict aerobic capacity associated to active limbs and breathing, in addition to whole body PET. Associating the studies' findings it is possible to conclude that there is a strict relationship of peripheral and central responses to RPE construct, being this sthrengthed by decreased oxygen availability. Furthermore, these relationship justifies the practical use RPE, as for prescription of high intensity exercise or localized monitoring of aerobic capacity / Doutorado / Ciencia do Desporto / Doutor em Educação Física
469

Dessaturação em teste incremental de caminhada / Desaturation in healthy subjects after the shuttle walk test

Seixas, Daniel Machado, 1980- 24 August 2018 (has links)
Orientador: Ilma Aparecida Paschoal / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciências Médicas / Made available in DSpace on 2018-08-24T07:53:53Z (GMT). No. of bitstreams: 1 Seixas_DanielMachado_M.pdf: 1848962 bytes, checksum: 80ebf21f0114a4503b21846263f7ad6d (MD5) Previous issue date: 2012 / Resumo: O "Shuttle Walking Test" (SWT), padronizado na literatura como um teste de esforço submáximo e utilizado em pacientes com DPOC (Doença Pulmonar Obstrutiva Crônica), foi aplicado em indivíduos saudáveis para verificar se a dessaturação, após a realização deste teste, é um evento provável. Foram selecionados indivíduos saudáveis, praticantes de atividade física pelo menos 2 vezes por semana em academia de ginastica. Os indivíduos que tivessem antecedentes de doenças pulmonares e/ou cardíacas ou qualquer outra condição de saúde que impossibilitassem a realização do teste foram excluídos do estudo. Os valores de fluxo expiratório do primeiro segundo e do sexto segundo (VEF1 e VEF6) foram determinados antes da realização dos testes através de um medidor digital de pico de fluxo (Peck Flow). Outros parâmetros avaliados antes do SWT foram frequência cardíaca basal e saturação de oxigênio inicial. Logo após o final do teste foram verificados os mesmos parâmetros do início do teste. A versão do SWT utilizada neste trabalho foi a modificada, com 12 níveis de intensidade. Oitenta e três indivíduos (55 homens) foram selecionados (apenas um fumante). A idade média foi 35,05 ± 12,53. O índice de massa corporal (IMC) foi de 24,30 ± 3,47. A média de frequência cardíaca de repouso foi de 75,12 ± 12,48. A média da saturação periférica de O2 (SpO2) em repouso foi 97,96% ± 1,02%. A média do VEF1 foi de 3,75 ± 0,81 L; a média de VEF6 foi de 4,45 ± 0,87 L. A média VEF1/VEF6 foi de 0,83 ± 0,08 (sem restrição e / ou obstrução). A média de distância percorrida foi 958,30 ± 146.32m. A média da frequência cardíaca após SWT foi 162,41 ± 18,24. A média da SpO2 final foi 96,27% ± 2,21%. Onze indivíduos apresentaram maiores valores de SpO2 final; 17 indivíduos tiveram quedas na SpO2 final, igual ou superior a 4 pontos. A comparação entre os grupos, com e sem dessaturação, não mostraram diferenças em idade, sexo, VEF1, VEF6, VEF1/VEF6, saturação inicial, distância caminhada, frequência cardíaca e percentual da frequência cardíaca máxima. O IMC foi maior naqueles que dessaturaram (p = 0,01) e SpO2 final foi menor (p <0,0001). Estes resultados permitem concluir que pessoas saudáveis podem dessaturar após SWT e desta forma, a utilização do SWT para predição de doenças respiratórias leves pode não ser adequada. Dessaturação é comum em indivíduos saudáveis após o SWT, como na atividade física intensa, e pode ter efeitos deletérios. / Abstract: Aim. To perform the shuttle walk test in healthy individuals to determine if desaturation at the end of the test is a probable finding. Healthy subjects were enrolled. Antecedents of pulmonary and/or cardiac diseases or any other health condition were exclusion criteria. FEV1 and FEV6 were determined before the SWT (digital peak flow meter). Baseline heart rate and oxygen saturation were determined with a pulse oxymeter. The SWT was the 12-level version. Saturation was measured after the SWT. Results. 83 subjects (55men) were enrolled (one smoker). Mean age was 35.05±12.53. Mean body mass index (BMI) was 24.30±3.47. Mean rest heart rate was 75.12±12.48. Mean rest SpO2 was 97.96%±1.02%. Mean FEV1 was 3.75±0.81 L; mean FEV6 was 4.45±0.87 L. Mean FEV1/FEV6 was 0.83±0.08 (no restriction and/or obstruction). Mean walk distance was 958.30±146.32m. Mean heart after SWT was 162.41±18.24. Mean final SpO2 was 96.27%±2.21%. Eleven subjects had greater values of final SpO2; 17 subjects had falls in final SpO2 ? 4 points. The comparison between the groups with and without desaturation showed no differences in age, sex, FEV1, FEV6, FEV1/FEV6, initial saturation, walk distance, heart rate and percentage of maximum heart rate. BMI was higher in those who desaturate (p=0.01) and final SpO2 was smaller (p<0.0001). Conclusion. Healthy people may desaturate after SWT; its use to predict the presence of subtle respiratory disorders, may be misleading. Desaturation is common in healthy subjects after the SWT as in intense physical activity and may have deleterious effects. / Mestrado / Clinica Medica / Mestre em Clinica Medica
470

Desenvolvimento do metodo multivariado acelerado para determinação do prazo de validade de produtos unindo quimiometria e cinetica quimica / Development of the multivariate accelerated shelf-life test for determining the shelf-life of products using chemometrics and chemical kinetics

Pedro, Andre Messias Krell 14 August 2018 (has links)
Orientador: Marcia Miguel Castro Ferreira / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Quimica / Made available in DSpace on 2018-08-14T13:05:23Z (GMT). No. of bitstreams: 1 Pedro_AndreMessiasKrell_D.pdf: 1179705 bytes, checksum: 302be0a6ab2e796d557a625c76f92bc4 (MD5) Previous issue date: 2009 / Resumo: DESENVOLVIMENTO DO MÉTODO MULTIVARIADO ACELERADO PARA DETERMINAÇÃO DO PRAZO DE VALIDADE DE PRODUTOS UNINDO QUIMIOMETRIA E CINÉTICA QUÍMICA descreve um novo conceito de análise de dados que permite avaliar os mecanismos que governam a degradação de bens de consumo e determinar o período de tempo no qual os bens de consumo mantém suas características dentro de níveis aceitáveis. O algoritmo une técnicas quimiométricas com a teoria cinética química formal, constituindo um avanço sobre os protocolos para determinação da validade de produto existentes. Além de ser de fácil interpretação, suas principais vantagens incluem a capacidade de unir informações provenientes de diferentes disciplinas ¿ analíticos, físico-químicos, sensoriais - e a possibilidade de utilização direta de dados oriundos de instrumentação analítica como espectroscópios, cromatógrafos, calorímetros, etc. O trabalho é dividido em seis capítulos. O Capítulo I traz uma revisão da cinética química e dos métodos convencionais para determinação do prazo de validade de produtos. O algoritmo do Método Multivariado Acelerado, bem como suas premissas, vantagens e desvantagens, são descritos no capítulo II. Os Capítulos III e IV trazem aplicações do Método Multivariado Acelerado. No Capítulo III dados físico-químicos e sensoriais foram utilizados para determinar o prazo de validade de um produto alimentíco. No Capítulo IV utilizaram-se dados instrumentais, oriundos de espectroscopia no infravermelho próximo (NIR), como fonte de informação quantitativa que, aliados a avaliações sensoriais, permitiram a determinação da validade de um produto cosmético e forneceram informações relevantes sobre seus modos de degradação. Uma comparação com o método tri-linear PARAFAC é apresentada no Capítulo V. Apesar de constituir ferramenta importante para avaliação dos modos de degradação de produtos, o método PARAFAC carece de estratégias para determinação efetiva do prazo de bens de consumo. Finalmente, o Capítulo VI mostra o desenvolvimento de um protocolo para determinação de várias propriedades de produtos concentrados de tomate utilizando regressão PLS2. Demonstrou-se que, apesar da preferência pelo método de calibração PLS1 por parte dos pesquisadores, a regressão PLS2 é vantajosa quando há correlação entre propriedades cujos métodos de referência são precisos e outras, cuja quantificação é imprecisa. / Abstract: DEVELOPMENT OF THE MULTIVARIATE ACCELERATED SHELF-LIFE TEST (MASLT) FOR DETERMINING THE SHELF-LIFE OF PRODUCTS BY MERGING CHEMOMETRICS AND CHEMICAL KINETICS describes a new concept of data analysis for evaluating the mechanisms that rule out the degradation of consumer goods. The algorithm herein developed took advantage of the soft modeling concepts from chemometrics and of chemical kinetics for determining the period of time within which products would be able to keep their quality characteristics within acceptable levels. Besides being of easy interpretation, the main advantages of the MASLT are the capacity to merge data from different sources ¿ analytical, physical chemical, sensorial ¿ and the ability of handling instrumental data (spectroscopic, chromatographic, calorimetric, etc.) directly for determining the shelf-life of products. This work and some applications are presented in six chapters. In Chapter I, a review of the chemical kinetics theory, as well as the concepts of conventional shelf-life methods, is presented. The MASLT algorithm, together with its assumptions, characteristics and advantages, is presented in Chapter II. Chapters III e IV describe applications where the shelf-life was determined successfully by using the MASLT. In Chapter III, physical chemical and sensorial data were merged not only for determining the shelf-life of an industrialized tomato product, but also to study the correlation between the various properties. In Chapter IV, instrumental data from NIR spectroscopy were used as source of quantitative information and, together with sensory analyses, allowed the determination of the shelf-life of a cosmetic product as well as provided valuable information with regards to its degradation mechanisms. A comparison between the tri-linear method PARAFAC is presented in Chapter V. Despite being an important tool for evaluating the degradation mechanisms of consumer goods, the PARAFAC method lacks strategies for effectively determining the shelf-life of products. Finally, Chapter VI describes the development of a new protocol for determining several properties of tomato concentrate products using PLS2 regression. It was demonstrated that, despite most researchers having a preference for using PLS1 regression, PLS2 is advantageous when there is strong correlations between properties that can be determined quite accurately by their reference methods with those presenting lower accuracy. / Doutorado / Físico-Química / Doutor em Ciências

Page generated in 0.0483 seconds