• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 17
  • 10
  • 2
  • Tagged with
  • 28
  • 28
  • 16
  • 9
  • 9
  • 8
  • 8
  • 8
  • 7
  • 7
  • 5
  • 5
  • 5
  • 5
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Etude des interactions hydro-chimio-mécaniques dans les tissus biologiques : application à la nutrition du disque intervertébral. / Analysis of hydro-chemo-mechanical interactions in biological tissues : application to the cell nutrition of intervertebral disc

Baldit, Adrien 20 September 2013 (has links)
Le disque intervertébral est principalement composé de deux types de tissu : le nucleus pulposus au centre contenu par l'annulus fibrosus en périphérie.Le nucleus est relativement bien décrit dans la littérature contrairement à l'annulus dont la constitution bi-phasique couplée à une structure à fibres orientées reste délicate à modéliser. La caractérisation hydro-chimio-mécanique représente un point clé dans la compréhension des phénomènes qui régissent le comportement de l'organe.Pour répondre au manque d'information, deux axes de travail sont mis en place : expérimental et numérique.La réalisation de tests de traction cyclique associés à des techniques de corrélation d'images permet de fournir une base de données complète du comportement.Elle est ensuite utilisée pour identifier un modèle hydro-chimio-mécanique qui traduit le comportement non-linéaire, anisotrope, dissipatif ainsi que la sensibilité aux variations d'environnement chimique du tissu observés expérimentalement.L'intérêt majeur de cette méthode est l'identification simultanée de l'ensemble des paramètres du modèle au cours de sollicitations proches des conditions physiologiques sur chacune des éprouvettes.Ce protocole réduit ainsi les incertitudes liées aux variabilités inter-individus et inter-localisations pour obtenir des valeurs de paramètres plus fiables.La formulation identifiée permettra de proposer un modèle compréhensif des transferts de fluide impliqués dans les processus de nutrition cellulaire.Ce sujet s'intègre dans une réflexion plus large relative à la compréhension des couplages hydro-chimio-mécaniques dans les tissus biologiques.L'enjeu est de quantifier l'impact des stimuli mécaniques sur l'évolution des tissus humains et leur adaptation aux conditions environnementales. / Intervertebral disc is mainly divided into two parts : nucleus pulposus surrounding by annulus fibrosus.Nucleus is relatively well described in literature, on the other hand annulus remains difficult to model due to its bi-phasic constitution coupled with an oriented fibres structure.Hydro-chemo-mechanical characterization represent a key point to reach a better understanding of this organ.To overcome this lack of knowledge, two axes are developed in this work : experimental and numerical.Cyclic tensile tests associated to digital image correlation techniques allow to obtain a large amount of data on global tissue behaviour.It permit to identify a hydro-chemo-mechanical model which takes in account the non-linear, anisotropic and dissipative behaviours.It also highlights sensibility to chemical variations in tissue environment observed experimentally.The most important point of this work is the simultaneous parameter identification performed on each sample during solicitations similar to in vivo conditions.This protocol reduce inter-individuals and inter-localisations discrepancies and leads to an accurate bundle of parameters.The formulation aims to accurately model fluid motion inside intervertebral disc tissues which is related to cell nutrition, growth and homoeostasis.This work is involved in a larger problematic about hydro-chemo-mechanical coupling within biological tissues.It will allow to quantify mechanical stimuli influence on human tissues evolution and adaptation to environment conditions.
22

Elastographie ultrasonore des tissus mous du membre inférieur en vue de la caractérisation des effets mécaniques de dispositifs médicaux textiles / Elastographic and biomechanical studies of soft tissues of the leg – Application to elastic compression

Frauziols, Fanny 14 December 2015 (has links)
La compression élastique de la jambe est le traitement de référence des pathologies liées à l’insuffisance veineuse. Bien que l’efficacité ne soit plus à prouver, les objectifs thérapeutiques restent non atteints pour certains patients. Un objectif de la compression élastique est la réduction de la pression pariétale des veines afin de rétablir ou d’augmenter le retour du sang vers le cœur par une transmission de pression au travers des tissus mous. Ce mécanisme est complexe et peut être prédit par des modèles éléments finis personnalisés. Pour être personnalisés, ces modèles doivent prendre en compte la géométrie et la carte des propriétés mécaniques du sujet.Dans cette étude, on développe deux méthodologies permettant d’identifier les propriétés mécaniques des tissus mous. Dans un premier temps, on mesure par élastographie ultrasonore par onde de cisaillement la distribution du module élastique au sein des tissus mous superficiels. Dans un deuxième temps, on identifie par une méthode inverse les propriétés mécaniques des tissus mous profonds. Cette méthode associe l’acquisition de données d’un essai expérimental de compression localisée de la jambe à un modèle éléments finis bidimensionnel. Ces deux méthodologies nous permettent d’évaluer l’hétérogénéité des propriétés mécaniques de la peau au fascia cruris et de caractériser le comportement non-linéaire des tissus mous profonds. Enfin, les résultats de ces deux méthodologies sont couplés afin de générer un modèle biomécanique de la jambe sous compression élastique pour prédire la distribution de pression au sein des tissus mous pour quatre sujets sains. / Elastic compression of the leg is a widely used treatment in case of pathologies related to venous insufficiency. Its benefits are not to be proven, but still, for some patients, the therapeutic goal is not reached. One goal of this treatment is to reduce transmural pressure applied to veins in order to restore or increase blood return to the heart by the transmission of the external pressure through soft tissues. This is a complex mechanism that can be predicted by patient-specific finite element models. To be patient-specific, these models must take into account the geometry and the distribution of mechanical properties of each subject.In this study, two methodologies are developed to identify the mechanical properties of soft tissues. First, the elastic modulus distribution inside the superficial soft tissues is measured by shear wave ultrasound elastography. Second, the mechanical properties of deep soft tissues are identified through an inverse method combining the data acquired from an experimental localized compression of the leg to a bi-dimensional finite element model.These two methodologies allow to evaluate the mechanical properties heterogeneity from the skin to the fascia cruris and to characterize the non-linear behaviour of deep soft tissues. Finally, the results from both methodologies are brought together to generate a biomechanical model of the leg under elastic compression to predict pressure distribution inside soft tissues for four healthy subjects.
23

Reconstitution faciale par imagerie 3d : variabilité morphométrique et mise en oeuvre informatique

Guyomarc'h, Pierre 28 November 2011 (has links)
La reconstitution faciale a pour but de restituer le visage d’un individu à partir de la morphologie de son crâne. Cette technique est utilisée en anthropologie médico-légale pour apporter de nouveaux témoignages dans l’identification de restes humains. Les objectifs de thèse sont d’établir une base de données crânio-faciale 3D de Français grâce à l’imagerie médicale, de tester les règles traditionnelles de reconstitution, et de quantifier les corrélations morphologiques entre tissus osseux et cutanés. Des examens hospitaliers par scanner tomodensitométrique (18 – 96 ans ; sexe ratio 1,16:1) ont été traités avec le logiciel TIVMI pour reconstruire avec précision les surfaces osseuses et cutanées. Plus de 200 points de repère ont pu être positionnés sur 500 individus, en suivant un protocole précis (répétabilité et reproductibilité vérifiées). L’extraction de distances Euclidiennes a permis de tester plusieurs règles traditionnelles, et d’étudier la spécificité et la variabilité des épaisseurs de tissus mous. Parallèlement, les coordonnées 3D des points ont été analysées par morphométrie géométrique. Les covariations entre groupes de points osseux et cutanés ont pu être quantifiées, ainsi que les asymétries, allométries, et influences de l’âge et du sexe sur les variations de conformation. Ces résultats ont permis l’élaboration d’une méthode d’estimation de la position des points de repère du visage, et la création (en collaboration avec le LaBRI) d’un module de reconstitution faciale nommé AFA3D. Basé sur le principe de déformation d’un visage synthétique, ce logiciel restitue la forme la plus probable du visage en fonction de la position de 78 points crâniométriques. / Facial approximation aims at the production of a face based on the skull morphology. This technique is performed in forensic anthropology to bring new testimonies in cases of human remains identification. The goals of this research are to establish a database of French skulls and faces in 3D through medical imaging, to test traditional guidelines, and to quantify the morphological correlations between soft and hard tissues. Computed tomography exams, collected in French hospitals (18 – 96 years; sex ratio 1.16:1), were treated with TIVMI software to reconstruct accurately the bone and skin surfaces. More than 200 landmarks have been placed on 500 subjects, following a protocol which repeatability and reproducibility have been checked. The extraction of Euclidian distances allowed testing traditional guidelines, and studying specificity and variability of soft tissue depths. In parallel, the 3D coordinates were analyzed with geometric morphometrics. Covariations between groups of bone landmarks and groups of skin landmarks were quantified, along with asymmetry, allometry, and influences of age and sex on the shape changes. These results allowed for the creation of a method to estimate the position of skin landmarks, and for the development of a facial approximation module in TIVMI, called AFA3D (in collaboration with the LaBRI). Based on the warping of a synthetic face, this software renders the most probable face depending on the position of 78 cranial landmarks.
24

Biomécanique des tissus mous de la jambe humaine sous compression élastique / Biomechanics of soft tissues of human leg under elastic compression

Dubuis, Laura 12 December 2011 (has links)
La compression élastique (CE) est un traitement médical qui est prescrit en cas d'insuffisance veineuse. Récemment, la CE rencontre aussi un certain succès auprès des sportifs pour la récupération. Cependant, malgré l’utilisation de plus en plus massive de la CE, son action biomécanique sur le membre inférieur n'est pas encore bien caractérisée. Pour contribuer à cette caractérisation, un modèle biomécanique 3D des tissus mous de la jambe sous CE a été développé et appliqué à un panel de sujets. Chaque modèle est personnalisé : la géométrie est reconstruite à partir des images tomographiques 3D de la jambe de chaque sujet et les conditions aux limites reproduisent fidèlement la pression localement appliquée par la CE sur la peau. De plus, les propriétés hyper-élastiques des tissus mous sont identifiées pour chaque sujet par recalage du modèle. Une méthode de recalage originale a été spécifiquement développée et mise en œuvre pour cette application : elle consiste à utiliser les images tomographiques 3D de la jambe déformée comme données expérimentales pour le recalage. Finalement, le modèle donne accès au champ de pression transmis par la CE aux tissus mous internes. Les principales conclusions sont que le champ de pression à l'intérieur de la jambe n'est pas transmis uniformément et qu'il y a de fortes variabilités inter-sujets. En outre, le modèle permet d'obtenir des indications sur le confort et l'efficacité de la CE. Il a ainsi été possible de montrer que l'intensité des pressions maximales subies par les tissus mous de la jambe est inversement proportionnelle à l’épaisseur du tissu adipeux. Les principales perspectives du travail concernent la validation clinique de ces conclusions sur un nombre significatif de sujets, puis leur exploitation en vue d’améliorer les traitements. / Elastic compression (EC) is a medical treatment prescribed in case of venous insufficiency. Recently, EC is also employed for recovery after efforts in sports. Nevertheless, despite the more and more common use of EC, its biomechanical action onto the lower limb remain partially unknown . To address this issue, a 3D biomechanical model of the soft tissues of the leg under EC has been developed and applied on a group of subjects. Each model is patient-specific: the geometry is reconstructed from the 3D CT-scan images of each subject’s legs and the boundary conditions are prescribed according to the local pressure applied by the EC onto the skin. Furthermore, the hyper-elastic properties of the soft tissues are identified for each subject using an inverse approach. The inverse approach is original: it consists in using the 3D CT-scan images of the deformed leg as experimental data for calibrating the model. The resulting model provides the pressure fields in the internal soft tissues induced by the EC. The main conclusions are that the pressure is not transmitted evenly and that significant inter-subject variability exists. Moreover, it is shown that the magnitude of the pressure undergone by the soft tissues is inversely proportional to the thickness of adipose tissues. The main perspectives of this work are to validate the conclusions on a significant number of subjects and to continue improving the treatments of venous insufficiency by EC.
25

Multi-body optimization method for the estimation of joint kinematics : prospects of improvement / Méthode d’optimisation multi-segmentaire pour l’estimation de la cinématique articulaire : propositions d’amélioration

Richard, Vincent 28 June 2016 (has links)
L'analyse du mouvement humain s'appuie généralement sur des techniques de suivi de marqueurs cutanés pour reconstruire la cinématique articulaire. Cependant, ces techniques d'acquisition présentent d'importantes limites dont les " artefacts de tissus mous " (i.e., le mouvement relatif entre les marqueurs cutanés et le squelette sous-jacent). La méthode d'optimisation multi-segmentaire viseà compenser ces artefacts en imposant aux trajectoires de marqueurs les degrés de liberté d'un modèle cinématique prédéfini. Les liaisons mécaniques modélisant classiquement les articulations empêchent toutefois une estimation satisfaisante de la cinématique articulaire. Cette thèse aborde des perspectives d'amélioration de la méthode d'optimisation multi-segmentaire pour l'estimation de la cinématique articulaire du membre inférieur,à travers différentes approches : (1) la reconstruction de la cinématique par suivi de la vitesse angulaire, de l'accélération et de l'orientation de centrales inertiellesà la place du suivi de marqueurs, (2) l'introduction d'un modèle articulaire élastique basé sur la matrice de raideur du genou, permettant une estimation physiologique de la cinématique articulaire et (3) l'introduction d'un modèle des artefacts de tissus mous " cinématique-dépendant ", visantà évaluer et compenser les artefacts de tissus mous simultanément avec l'estimation la cinématique articulaire. Ce travail a démontré la polyvalence de la méthode d'optimisation multi-segmentaire. Les résultats obtenus laissent espérer une amélioration significative de cette méthode qui devient de plus en plus utilisée en biomécanique, en particulier pour la modélisation musculo-squelettique / Human movement analysis generally relies on skin markers monitoring techniques to reconstruct the joint kinematics. However, these acquisition techniques have important limitations including the "soft tissue artefacts" (i.e., the relative movement between the skin markers and the underlying bones). The multi-body optimization method aims to compensate for these artefacts by imposing the degrees of freedom from a predefined kinematic model to markers trajectories. The mechanical linkages typically used for modeling the joints however prevent a satisfactory estimate of the joint kinematics. This thesis addresses the prospects of improvement of the multi-body optimization method for the estimation of joint kinematics of the lower limb through different approaches: (1) the reconstruction of the kinematics by monitoring the angular velocity, the acceleration and the orientation of magneto-inertial measurement units instead of tracking markers, (2) the introduction of an elastic joint model based on the knee stiffness matrix, enabling a physiological estimation of joint kinematics and (3) the introduction of a "kinematic-dependent" soft tissue artefact model to assess and compensate for soft tissue artefact concurrently with estimating the joint kinematics. This work demonstrated the versatility of the multi-body optimization method. The results give hope for significant improvement in this method which is becoming increasingly used in biomechanics, especially for musculoskeletal modeling
26

La reconstruction du mouvement du squelette : l'enjeu de l'artefact des tissus mous / The reconstruction of skeletal movement : the soft tissue artefact issue

Bonci, Tecla 08 May 2015 (has links)
Lors de l'analyse 3D du mouvement humain basée sur des marqueurs cutanés, la position des os ne peut être qu'indirectement estimée. Au cours d'une tâche, les déformations des tissus mous génèrent des déplacements des marqueurs par rapport à l'os : les artefacts de tissus mous (STA), entraînant des effets dévastateurs sur l'estimation de la position. La compensation des STA demeure une question ouverte. L'objectif de cette thèse est de contribuer à la solution de cette question cruciale. La modélisation des STA en utilisant des variables spécifiques mesurables est une condition préalable à son élimination. Un modèle corrigeant les trajectoires individuelles de marqueurs de la cuisse, calibré par des mesures directes des STA, est d'abord présenté. Les STA sont modélisés comme une combinaison linéaire des angles articulaires impliqués. Trois représentations des STA par une série de modes sont proposées : déplacements de marqueurs individuels, transformations géométriques de clusters de marqueurs (MCGT), et variations de forme de l'enveloppe de peau. Le MCGT permet de dissocier les composantes rigides et non rigides. Il a été démontré que seule la composante rigide affecte la cinématique articulaire. Un modèle de cette composante est alors défini pour les clusters cuisse et jambe. Un compromis acceptable entre la correction des STA et le nombre de paramètres a ainsi été obtenu. Les principales applications sont de générer une simulation réaliste des STA ; et surtout, en se concentrant sur la composante rigide, le modèle permet une reconstruction satisfaisante des STA avec moins de paramètres, ce qui facilite son incorporation dans un algorithme d'estimation de la position osseuse / In 3D human movement analysis performed using stereophotogrammetry and skin markers, bone pose can be only indirectly estimated. During a task, soft tissue deformations make the markers move with respect to the underlying bone generating soft tissue artefacts (STA), causing devastating effects on pose estimation and its compensation remains an open issue. The thesis’ aim was to contribute to the solution of this crucial issue. Modelling STA using measurable trial-specific variables is a prerequisite for its removal from marker trajectories. Two STA model architectures are proposed. A thigh marker-level model is first presented. STA was modeled as a linear combination of joint angles involved in the task. The model was calibrated with direct STA measures. The considerable number of model parameters led to defining STA approximations. Three definitions were proposed to represent STA as series of modes : individual marker displacements, marker-cluster geometrical transformations (MCGT), and skin envelope shape variations. Modes were selected using two criteria : modal energy and selecting them a priori. The MCGT allows to select either rigid or non-rigid components. It was also demonstrated that only the rigid component affects joint kinematics. A model of thigh and shank rigid component at cluster-level was then defined. An acceptable trade-off between STA compensation and number of parameters was obtained. These results lead to two main potential applications : generate realistic STAs for simulation
27

Simulation temps-réel d'interventions médicales impliquant des déformations et des interactions mécaniques entre les tissus et les outils (Manuscrit en anglais)

Duriez, Christian 01 February 2013 (has links) (PDF)
Les travaux de recherche présentés pour l'habilitation à diriger des recherches, visent à proposer de nouveaux outils pour simuler des interventions médicales et chirurgicales. Ces outils ont plusieurs applications dont l'amélioration de la formation des praticiens, la planification d'interventions pour la préparation et la validation d'une thérapie ou encore l'assistance au geste médical durant une intervention. Or, pour simuler ces interventions de manière réaliste voire prédictive, il faut tenir compte de la déformation des structures anatomiques et des interactions mécaniques entre les outils et les organes. En même temps, la simulation doit être interactive et calculée en temps-réel pour garder le geste du praticien dans la boucle de la simulation. Le défi majeur de notre travail est donc de garantir un calcul précis au niveau de la simulation tout en gardant un temps de calcul très court, qui soit compatible avec le temps-réel. D'abord, nous proposons une formulation optimisée de la méthode par éléments finis (FEM) et de nouveaux outils numériques (pré-conditionneurs, couplage entre modèles...) dédiés à au calcul FEM temps-réel. Cette approche est utilisée pour calculer la biomécanique des déformations des tissus anatomiques et les instruments flexibles. Nous abordons ensuite un autre point clé de ces simulations que sont les conditions aux limites. Les interactions mécaniques entre organes et/ou entre les outils chirurgicaux et les tissus sont souvent complexes à modéliser. Or, une mauvaise prise en compte de ces interactions peut aboutir à des erreurs importantes. Notre approche suit les bases de la mécanique non-régulière pour gérer, notamment, le contact et le frottement entre solides. Nous étendons l'approche à d'autres modèles d'interaction (comme l'insertion d'aiguille par exemple). Dans ce contexte, nous mettons l'accent sur le calcul de la compliance des structures en temps-réel. Par ailleurs, pour certaines interventions où le retour visuel n'est pas parfait, le praticien se guide aussi avec le sens du toucher. Il est donc important de reproduire au moins partiellement cette sensation - dite haptique - avec des interfaces à retour d'effort, pilotée à partir des données de la simulation. Dans ce domaine, nous proposons une approche centrée sur le rendu haptique des interactions mécaniques entre outil chirurgical et tissus humain. Cette approche se base notamment sur une désynchronisation du calcul de la boucle de simulation et de la boucle de retour d'effort qui demande un rafraichissement à haute fréquence (1kHz). Finalement, nous présentons ces résultats de recherche sur des exemples concrets d'application et nous présentons les défis à venir pour permettre à la simulation de devenir un outil utilisé par les praticiens à l'avenir. Le manuscrit est en anglais.
28

Etude des interactions hydro-chimio-mécaniques dans les tissus biologiques : application à la nutrition du disque intervertébral.

Baldit, Adrien 20 September 2013 (has links) (PDF)
Le disque intervertébral est principalement composé de deux types de tissu : le nucleus pulposus au centre contenu par l'annulus fibrosus en périphérie.Le nucleus est relativement bien décrit dans la littérature contrairement à l'annulus dont la constitution bi-phasique couplée à une structure à fibres orientées reste délicate à modéliser. La caractérisation hydro-chimio-mécanique représente un point clé dans la compréhension des phénomènes qui régissent le comportement de l'organe.Pour répondre au manque d'information, deux axes de travail sont mis en place : expérimental et numérique.La réalisation de tests de traction cyclique associés à des techniques de corrélation d'images permet de fournir une base de données complète du comportement.Elle est ensuite utilisée pour identifier un modèle hydro-chimio-mécanique qui traduit le comportement non-linéaire, anisotrope, dissipatif ainsi que la sensibilité aux variations d'environnement chimique du tissu observés expérimentalement.L'intérêt majeur de cette méthode est l'identification simultanée de l'ensemble des paramètres du modèle au cours de sollicitations proches des conditions physiologiques sur chacune des éprouvettes.Ce protocole réduit ainsi les incertitudes liées aux variabilités inter-individus et inter-localisations pour obtenir des valeurs de paramètres plus fiables.La formulation identifiée permettra de proposer un modèle compréhensif des transferts de fluide impliqués dans les processus de nutrition cellulaire.Ce sujet s'intègre dans une réflexion plus large relative à la compréhension des couplages hydro-chimio-mécaniques dans les tissus biologiques.L'enjeu est de quantifier l'impact des stimuli mécaniques sur l'évolution des tissus humains et leur adaptation aux conditions environnementales.

Page generated in 0.4487 seconds