• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1863
  • 23
  • 18
  • 18
  • 16
  • 16
  • 16
  • 10
  • 7
  • 7
  • 7
  • 6
  • 5
  • 4
  • 4
  • Tagged with
  • 1940
  • 1295
  • 1199
  • 806
  • 544
  • 362
  • 351
  • 327
  • 315
  • 248
  • 234
  • 214
  • 198
  • 179
  • 175
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
181

Avaliação dimensional do espaço aéreo faríngeo em crianças com diferentes morfologias faciais por meio da tomografia computadorizada do feixe cônico

Zinsly, Sabrina dos Reis [UNESP] 28 May 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:29:12Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-05-28Bitstream added on 2014-06-13T19:38:18Z : No. of bitstreams: 1 zinsly_sr_me_sjc.pdf: 1840664 bytes, checksum: 9af5fca2a2307f238c9eaee02ad4e681 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo neste estudo foi avaliar as diferenças no espaço aéreo faríngeo em crianças com diferentes padrões faciais. Foram avaliadas as tomografias computadorizadas de feixe cônico de 98 indivíduos em crescimento, com idade média de 8,9 anos, divididas por sexo e faixa etária, e subdivididas de acordo com o padrão de crescimento (horizontal, vertical normal e produtores) e tipo de má oclusão (Classe I e Classe II). Utilizando um programa tridimensional, foram analisados o volume, área sagital, menor área de seção transversal e as dimensões ântero-posteriores da faringe superior e inferior. As dimensões ântero-posterior da faringe superior e inferior foi significativamente menor em indivíduos com Classe II em crianças na faixa etária entre 9 a 11 anos e a faringe superior em foi significativamente menor em crianças na faixa etária entre 5 e 7 anos com padrão de crescimento vertical. Porém, quando a faringe foi avaliada tridimensionalmente, não foram encontradas diferenças nas demais dimensões sugerindo que diferenças no padrão vertical e no tipo de má oclusão ântero-posterior (Classe I e II) não influenciam as dimensões da faringe. Não foi encontrado dimorfismo sexual. A região de maior constrição da faringe esteve presente mais freqüentemente na orofaringe (86%). Embora as dimensões lineares possam variar entre os diferentes padrões faciais, quando avaliadas tridimensionalmente, elas não foram influenciadas pelas diferentes morfologias faciais / The aim of this study was to assess the differences in pharyngeal airway space in children with different facial patterns. Cone-beam computed tomography records of 98 growing patients with mean age of 8.9 years divided by sex and age groups and subdivided according to growth pattern (horizontal, normal and vertical growers) and type of malloclusion (Class I and Class II) were evaluated .Using a 3-dimensional virtual program the volume, sagital area, smallest cross section area, anteroposterior dimensions of superior and inferior pharynx were obtained. The anteroposterior linear dimensions of superior and inferior pharynx in children with 9 to11 years was significant smaller in patients with Class II relationship but in 3D evaluation differences were not found suggesting that anteroposterior malocclusion do not influence pharynx dimensions. The anteroposterior linear dimensions of superior , pharynx in children with 5 to7 years was significant smaller in patients with vertical growth pattern when compared to normal growers, but in 3D evaluation differences were not found suggesting that vertical pattern do not influence pharynx dimensions. No sexual dimorphism was found. The most constricted region of pharynx were mostly found at oropharynx(96%).Although linear dimensions can vary among different facial patterns, the 3-dimensional dimensions weren’t influenced by different facial morphologies
182

Quantificação de fibrose e enfisema em pacientes com paracoccidioidomicose (PCM) pulmonar, através de imagens de tomografia computadorizada de alta resolução (TCAR) /

Oliveira, Marcela de. January 2012 (has links)
Orientador: José Ricardo de Arruda Miranda / Coorientador: Diana Rodrigues de Pina / Banca: Rinaldo Pôncio Mendes / Banca: André Petean Trindade / Resumo: A Paracoccidioidomicose (PCM) é uma importante doença sistêmica que acomete os pulmões, e mesmo após tratamento eficaz deixa sequelas como fibrose e enfisemas pulmonares. É muito importante que as sequelas provenientes da doença sejam quantificadas com precisão. Assim, a Tomografia Computadorizada de Alta Resolução (TCAR) se tornou o exame de diagnóstico por imagem mais utilizado para a avaliação das sequelas da PCM. O diagnóstico auxiliado por sistemas computacionais pode ajudar a produzir uma avaliação mais precisa das sequelas (fibrose e enfisema) causadas pela PCM. Esta pesquisa tem como objetivo o desenvolvimento de algoritmos em ambiente computacional Matlab® capazes de quantificar objetivamente fibrose e enfisema em pacientes com PCM confirmada. O algoritmo consiste em selecionar a região de interesse (ROI), e por meio da utilização de máscaras, filtros de densidades e operadores morfológicos, obter a quantificação da área lesionada em relação à área sadia do pulmão. O método proposto foi testado em 30 exames de TCAR de pacientes com PCM confirmada. Os resultados das quantificações objetivas foram comparados com as avaliações visuais realizadas por um especialista da área de radiologia, e apresentaram uma maior diferença de 39,14% para fibrose e 18,7% para enfisema. Para validar a eficiência do método proposto nessa pesquisa, em distinguir as estruturas pulmonares e realizar suas quantificações, foi construído um fantoma virtual pulmonar. Os valores da composição do fantoma foram comparados com os valores obtidos pelo algoritmo, apresentando diferença de 11,5% para enfisema e de 4,5% para fibrose. Em relação à comparação dos resultados das composições dos fantomas com a avaliação visual realizada pelo radiologista, foi verificada uma diferença de 40% e 23% para fibrose e... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The paracoccidioidomycosis (PCM) is a major systemic disease affecting the lungs, and even after effective treatment leaves sequelae such as fibrosis and pulmonary emphysema. It is very important that the sequelae from disease be quantified with greater accuracy. Thus, the High Resolution Computed Tomography (HRCT) has become the diagnostic imaging test most widely used to assess the sequelae of the PCM. The computer-aided diagnosis systems can help produce a more precise assessment of the sequelae (fibrosis and emphysema) caused by PCM. This research aims to develop algorithms in environment Matlab® capable of objectively quantify fibrosis and emphysema in patients with PCM. The algorithm consists of selecting the region of interest (ROI), and by the use of masks, density filters and morphological operators, to obtain the quantification of lesion area compared to the area of healthy lung. The proposed method was tested on 30 HRCT scans of patients with PCM. The results of objective quantification were compared with visual evaluations performed by specialist radiology, and showed a greater difference of 39.14% and 18.7% for fibrosis and emphysema, respectively. To validate the efficiency of the proposed method in this research, in distinguishing lung structures and conduct their baseline, we built a virtual phantom lung. The values of the composition of the phantom were compared with the values obtained by the algorithm, showing a difference of 11.5% to emphysema and fibrosis to 4.5%. In comparing the results of compositions of the phantoms with the visual evaluation performed by the radiologist, there was a difference of 40% and 23% for fibrosis and emphysema, respectively. The objective quantification of fibrosis and emphysema is the original PCM. The results show the feasibility and reliability... (Complete abstract click electronic access below) / Mestre
183

Avaliação do programa de controle de qualidade e segurança dos equipamentos PET instalados em regiões do Brasil / Avalation about quality control program and safety PET equipment installed in regions of the Brazil

Souza, Jeane Serrão de 26 November 2014 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade UnB Gama, Engenharia Biomédica, 2014. / Submitted by Albânia Cézar de Melo (albania@bce.unb.br) on 2015-02-04T13:19:50Z No. of bitstreams: 1 2014_JeaneSerraoSouza.pdf: 4881835 bytes, checksum: a7ef077f3198020ea6c61714a7892345 (MD5) / Approved for entry into archive by Ruthléa Nascimento(ruthleanascimento@bce.unb.br) on 2015-02-10T19:47:15Z (GMT) No. of bitstreams: 1 2014_JeaneSerraoSouza.pdf: 4881835 bytes, checksum: a7ef077f3198020ea6c61714a7892345 (MD5) / Made available in DSpace on 2015-02-10T19:47:15Z (GMT). No. of bitstreams: 1 2014_JeaneSerraoSouza.pdf: 4881835 bytes, checksum: a7ef077f3198020ea6c61714a7892345 (MD5) / Os equipamentos de tomografia computadorizada por emissão de pósitron (PET, do inglês Positron Emission Tomography) são utilizados nos serviços de medicina nuclear para realização de exames oncológicos, neurológicos e cardiológicos. A comprovação da eficácia desta técnica, impulsionou a instalação desses equipamentos no mundo. Para que as imagens permitam um diagnóstico com maior precisão, é necessário a realização de testes de desempenho para verificar se as condições de operação do equipamento estão adequadas dentro de um programa de controle de qualidade. Baseados na norma NN 3.05 – Requisitos de Segurança e Proteção Radiológica para Serviços de Medicina Nuclear da Comissão Nacional de Energia Nuclear (CNEN) e Resolução da Diretoria Colegiada n 38 - Sobre a Instalação e Funcionamento de Serviços de Medicina Nuclear “in vivo” da Agência Nacional de Vigilância Sanitária (ANVISA) verificou-se quais os testes estão sendo realizados e as periodicidades dominantes bem como os principais motivos que dificultam sua realização, como e quais são os registros realizados, as características dos equipamentos e equipe técnica, entre outros. A coleta dos dados baseou-se na aplicação de um questionário on line encaminhado por correio eletrônico aos supervisores de radioproteção dos serviços de medicina nuclear. Os dados foram analisados por meio da estatística descritiva com auxílio de gráficos, tabelas, verificação de hipóteses e correlações entre parâmetros com o auxílio do teste de Wilcoxon não pareado utilizando-se o software Matlab. Identificou-se que os testes que não são realizados estão relacionados com a ausência de acessórios e fantomas NEMA, falta de treinamento dos supervisores de radioproteção e deficiências nos treinamentos disponibilizados pelos fabricantes. Foi possível conhecer as perspectivas dos profissionais em relação ao tema, mapear as dificuldades e benefícios alcançados com a realização dos mesmos e desenvolver diretrizes para auxiliar os profissionais da área no planejamento, preparação e implantação de um programa de controle de qualidade de equipamentos PET. _______________________________________________________________________ ABSTRACT / The positron emission computed tomography equipment (PET) are used in nuclear medicine services to perform oncological, neurological and cardiological examinations. Evidence of the effectiveness of this technique, stimulated the installation of such equipment in the world. So that images allow a diagnosis more accurately, it is necessary to conduct performance tests to verify if the operating conditions of the equipment are appropriate within a quality control program. Based on norm NN 3.05 - Security Requirements for Radiological Protection and Nuclear Medicine Services of the National Nuclear Energy Commission (CNEN) and Resolution n 38 - About the installation and operation of nuclear medicine services "in vivo" of National Health Surveillance Agency (ANVISA) verify what tests are being conducted and the dominant periodicities as well as the main reasons that hinder their achievement, how and what are the comparisons of the characteristics of the equipment and technical staff, among others. Data collection was based on the application of an on line questionnaire sent by email to the radioprotection supervisors of nuclear medicine services. Data were analyzed using descriptive statistics with the aid of charts, tables, testing hypotheses and correlations between parameters with the Wilcoxon not paired test using the Matlab software. It was identified that the tests that are not performed are related to the lack of accessories and NEMA phantoms, lack of training for radioprotection supervisors and deficiencies in training offered by manufacturers. Was possible to know the views of professionals on the topic, map the difficulties and benefits achieved with their realization and develop guidelines to assist professionals in planning, preparation and implementation of a program of quality control of PET equipment.
184

Avaliação da influência do volume do campo de visão na determinação da densidade mineral em tomografia computadorizada de feixe cônico e tomografia computadorizada multislice

Rodrigues, Andréia Fialho 29 October 2013 (has links)
Submitted by isabela.moljf@hotmail.com (isabela.moljf@hotmail.com) on 2017-07-04T10:50:47Z No. of bitstreams: 1 andreiafialhorodrigues.pdf: 1214952 bytes, checksum: 9f8b3461dead1f5e477600658f658442 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2017-08-08T14:15:16Z (GMT) No. of bitstreams: 1 andreiafialhorodrigues.pdf: 1214952 bytes, checksum: 9f8b3461dead1f5e477600658f658442 (MD5) / Made available in DSpace on 2017-08-08T14:15:16Z (GMT). No. of bitstreams: 1 andreiafialhorodrigues.pdf: 1214952 bytes, checksum: 9f8b3461dead1f5e477600658f658442 (MD5) Previous issue date: 2013-10-29 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / As imagens de tomografia computadorizada de feixe cônico (TCFC) têm sido utilizadas para a avaliação da qualidade óssea, entretanto algumas variáveis inerentes ao exame parecem influenciar os valores de densidade obtidos, sendo que a influência do volume do campo de visão (FOV) ainda não foi completamente explicada. O objetivo deste estudo foi determinar os efeitos do volume do FOV no valor da densidade em TCFC e tomografia computadorizada multislice (TCMS). Um objeto teste composto por três cilindros de acrílico contendo água destilada, gesso e óleo de motor foi construído e inserido em um cilindro de acrílico completamente preenchido com água destilada. O objeto teste foi escaneado com uma TCFC e com uma TCMS, utilizando três tamanhos de FOV: 8x8cm, 16x8cm e 16x13cm. A densidade de cada material foi avaliada em 40 regiões de interesse posicionadas nos cortes axiais. Nos exames de TCFC, houve diferença significativa entre os valores de densidade dos diferentes FOVs para os três materiais. Já nos exames de TCMS houve diferença significativa somente para o óleo. Os valores de densidade mostraram significante correlação entre os exames de TCFC e TCMS para o gesso em todos os FOVs. A água não apresentou correlação significante entre os exames de TCFC e TCMS com os FOVs utilizados. O óleo não apresentou correlação no FOV 8 x 8mm e apresentou uma baixa correlação nos FOVs 16 x 8mm e 16 x 13mm. Os valores de densidade determinados em imagens de TCFC sofreram interferência significativa pela variação do tamanho do FOV. Os valores de densidade obtidos em exames de TCMS apresentaram diferença estatisticamente significante somente para o óleo. / Computed tomography cone beam (CBCT) scans have been used to evaluate the quality of bone. The values of density seem to be influenced by some CBCT inherent variables. However, some variables inherent to CBCT seem to influence the values of density and the influence of FOV volume has not been completely elucidated. The aim of this study was to determine the effects of FOV size on density values in large-volume CBCT and MSCT images. A phantom made up of 3 cylinders containing distilled water, plaster and motor oil was constructed and inserted into an acrylic cylinder filled with distilled water. The phantom was scanned with a CBCT and MSCT device using 3 FOV sizes. Density of each material was evaluated in 40 regions of interest. In CBCT exams there was significant difference between the density values of different FOVs for the 3 materials. In the MSCT there was significant difference only for the oil. A significant correlation between CBCT and MSCT exams for the plaster in all of the FOVs was obtained. The water did not show significant correlation between CBCT and MSCT exams with the FOVs under study. The oil was not correlated in 8 x 8mm FOV and a low correlation of the FOVs 16 x 8mm and 16 x 13mm. The density values determined in CBCT images showed significant interference by varying the size of the FOV. The density values obtained in MSCT examinations showed a statistically significant difference only for oil.
185

Avaliação dimensional do espaço aéreo faríngeo em crianças com diferentes morfologias faciais por meio da tomografia computadorizada do feixe cônico /

Zinsly, Sabrina dos Reis. January 2010 (has links)
Resumo: O objetivo neste estudo foi avaliar as diferenças no espaço aéreo faríngeo em crianças com diferentes padrões faciais. Foram avaliadas as tomografias computadorizadas de feixe cônico de 98 indivíduos em crescimento, com idade média de 8,9 anos, divididas por sexo e faixa etária, e subdivididas de acordo com o padrão de crescimento (horizontal, vertical normal e produtores) e tipo de má oclusão (Classe I e Classe II). Utilizando um programa tridimensional, foram analisados o volume, área sagital, menor área de seção transversal e as dimensões ântero-posteriores da faringe superior e inferior. As dimensões ântero-posterior da faringe superior e inferior foi significativamente menor em indivíduos com Classe II em crianças na faixa etária entre 9 a 11 anos e a faringe superior em foi significativamente menor em crianças na faixa etária entre 5 e 7 anos com padrão de crescimento vertical. Porém, quando a faringe foi avaliada tridimensionalmente, não foram encontradas diferenças nas demais dimensões sugerindo que diferenças no padrão vertical e no tipo de má oclusão ântero-posterior (Classe I e II) não influenciam as dimensões da faringe. Não foi encontrado dimorfismo sexual. A região de maior constrição da faringe esteve presente mais freqüentemente na orofaringe (86%). Embora as dimensões lineares possam variar entre os diferentes padrões faciais, quando avaliadas tridimensionalmente, elas não foram influenciadas pelas diferentes morfologias faciais / Abstract: The aim of this study was to assess the differences in pharyngeal airway space in children with different facial patterns. Cone-beam computed tomography records of 98 growing patients with mean age of 8.9 years divided by sex and age groups and subdivided according to growth pattern (horizontal, normal and vertical growers) and type of malloclusion (Class I and Class II) were evaluated .Using a 3-dimensional virtual program the volume, sagital area, smallest cross section area, anteroposterior dimensions of superior and inferior pharynx were obtained. The anteroposterior linear dimensions of superior and inferior pharynx in children with 9 to11 years was significant smaller in patients with Class II relationship but in 3D evaluation differences were not found suggesting that anteroposterior malocclusion do not influence pharynx dimensions. The anteroposterior linear dimensions of superior , pharynx in children with 5 to7 years was significant smaller in patients with vertical growth pattern when compared to normal growers, but in 3D evaluation differences were not found suggesting that vertical pattern do not influence pharynx dimensions. No sexual dimorphism was found. The most constricted region of pharynx were mostly found at oropharynx(96%).Although linear dimensions can vary among different facial patterns, the 3-dimensional dimensions weren't influenced by different facial morphologies / Orientador: Luiz Cesar de Moraes / Coorientador: Weber José da Silva Ursi / Banca: Jefferson Luis OshiroTanaka / Banca: Edmundo Medici Filho / Mestre
186

Diagnóstico diferencial das manifestações pulmonares agudas do lúpus eritematoso sistêmico com o auxílio da tomografia computadorizada

Veloso, Júlia de Castro Vieira January 2019 (has links)
Orientador: Sergio Marrone Ribeiro / Resumo: Introdução: O Lúpus Eritematoso Sistêmico (LES) é uma afecção reumatológica autoimune, de etiologia multifatorial, mais comum em mulheres na menacme. O comprometimento pulmonar pelo LES pode culminar com complicações pulmonares agudas como a Pneumonite Lúpica aguda (PLA), Hemorragia Alveolar Difusa (HAD) ou Pneumonia infecciosa (PN), com altos índices de morbimortalidade e tratamentos diferentes. Objetivos: Estabelecer o número de casos de complicações pulmonares agudas do LES e analisar suas manifestações tomográficas, com o propósito de caracterizar os padrões de acometimento pela PLA, HAD e PN, além de apontar achados de imagem e parâmetros clínicos e laboratoriais que auxiliem no diagnóstico diferencial entre elas. Método: Estudo observacional descritivo e retrospectivo, do tipo de série de casos, no qual foram analisados os prontuários eletrônicos dos pacientes com diagnóstico de LES entre Janeiro de 2011 e Dezembro de 2018 que apresentaram PLA, HAD ou PN. Foram colhidos dados do prontuário eletrônico e analisadas as Tomografias Computadorizadas de Alta Resolução (TCAR). Resultados: Dentre os 359 pacientes com diagnóstico de LES acompanhados no serviço, foram identificados 21 eventos independentes de complicações pulmonares agudas, sendo eles 12 episódios de PLA, 6 de PN e 3 de HAD. Os episódios de PN apresentaram maior prevalência de leucocitose e consolidações à TCAR, metade deles com vidro fosco. Metade dos eventos de PLA apresentou uma relação entre velocidade de hem... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Introduction: Systemic Lupus Erythematosus (SLE) is an autoimmune disease with multifactorial etiology, more common in reproductive age women. Pulmonary involvement by SLE may lead to acute pulmonary complications such as acute Lupus Pneumonitis (ALP), Diffuse Alveolar Hemorrhage (DAH) or infectious pneumonia (PN), with high morbidity and mortality rates and different treatments. Purpose: To establish the number of cases of acute pulmonary complications of SLE and analyze their tomographic manifestations, in order to recognize the patterns of involvement by ALP, DAH and PN, besides pointing out image findings, clinical and laboratory parameters that help distinguishing them. Methods: Descriptive, retrospective and observational study, in which electronic records of patients diagnosed with SLE between January 2011 and December 2018 who presented PLA, HAD or PN were analyzed. Data was obtained from the electronic medical record and the High Resolution Computed Tomographies (HRCT). Results: Among the 359 patients diagnosed with SLE followed in this service, 21 independent events of acute pulmonary complications were identified. There were 12 episodes of ALP, 6 of PN and 3 of DAH. PN episodes had a higher prevalence of leukocytosis, consolidations at HRCT and half of them had ground glass opacities. Half of the ALP events had an erythrocyte sedimentation rate and C-reactive protein (CRP) ratio above 15, with CRP within the limits of normality in 83,33%. One-third of ALP events ha... (Complete abstract click electronic access below) / Mestre
187

Reconhecimento qualitativo de pequenas reabsorções externas radiculares dentais por meio de imagens radiográficas convencionais, digitais e tomográficas / Qualitative recognition of small external root resorptions radicular through imagem radiography conventional and digital radiography and through computerized tomography

Castro, Cristiany Basilio 31 October 2008 (has links)
O presente estudo tem como objetivo avaliar in vitro, eficiência da radiografia convencional, e radiografia digital comparando-as à tomografia computadorizada no diagnóstico das reabsorções radiculares externas em diferentes localizações. Foram utilizados 6 dentes sendo, dois incisivos centrais direito e esquerdos, dois incisivos laterais direito esquerdos e dois caninos um direito e outro esquerdo, onde foram realizadas, cavidades simulando reabsorções externas de 0,5 mm de diâmetro nos terços cervical, médio e apical da superfície radicular, nas faces, vestibular, palatina, mesial e distal. Os dentes foram reposicionados no alvéolo do crânio seco, e esse revestido com uma camada de silicone com 4 mm de espessura, para simulação do tecido mole. Foram radiografados pela técnica convencional e digital e submetidos a exames de tomografia computadorizada volumétrica, sendo que as tomadas radiográficas foram observadas por três examinadores, que definiram a presença ou ausência das cavidades e sua localização. Os resultados mostraram que a radiografia convencional propiciou um percentual maior de reconhecimento do que a tomografia computadorizada, que por sua vez foi seguida da radiografia digital. O exame de tomografia computadorizada apresentou maior percentual de acertos quanto à localização com 65% das cavidades localizadas, seguidas das radiografias convencionais (56%) e por último as digitais com 51% das cavidades localizadas. Concluiu se que as radiografias convencionais são eficientes no reconhecimento das reabsorções radiculares, e a tomografias computadorizadas na precisão da localização. / The purpose of this study was to evaluate in vitro the efficiency of conventional and digital radiography when compared to the computerized tomography (CT) on diagnose of external root resorptions in different root locations. It was used 6 upper teeth: 2 right and left central incisors, 2 right and left lateral incisors, and 2 right and left canines. Simulated external root resorption cavities of 0.5 mm diameter were made on the cervical, middle and apical thirds, on the buccal, palatal, mesial and distal faces. The teeth were replaced on the dried skull alveolus, covered with a 4 mm silicon layer to simulate the soft tissue and were conventional and digital radiographed. Then they were submitted to the volumetric computerized tomography. The exams were evaluated by 3 examiners that observed the presence and absence of the cavities and their location. The results showed that the conventional radiography allowed better recognition than the CT. The CT was followed by the digital radiograph and allowed higher number of recognitions when the location was considerate, with 65% of the cavities localized, followed by the conventional radiographs (56%) and the last was the digital radiographs with 51% of located cavities. We concluded that conventional radiographs are efficient for root resorption recognition and the CT on the placement precision.
188

Desenvolvimento de algoritmo de imagens absolutas de tomografia por impedância elétrica para uso clínico. / Development of an absolute image algorithm for electrical impedance tomography for clinical application.

Camargo, Erick Darío León Bueno de 20 May 2013 (has links)
A Tomografia de Impedância Elétrica é uma técnica de obtenção de imagens não invasiva que pode ser usada em aplicações clínicas para estimar a impeditividade dos tecidos a partir de medidas elétricas na superfície do corpo. Matematicamente este é um problema inverso, não linear e mal posto. Geralmente é usado um filtro espacial Gaussiano passa alta como método de regularização para resolver o problema inverso. O objetivo principal deste trabalho é propor o uso de informação estatística fisiológica e anatômica da distribuição de resistividades dos tecidos do tórax, também chamada de atlas anatômico, em conjunto com o filtro Gaussiano como métodos de regularização. A metodologia proposta usa o método dos elementos finitos e o algoritmo de Gauss-Newton para reconstruir imagens de resistividade tridimensionais. A Teoria do Erro de Aproximação é utilizada para reduzir os erros relacionados à discretização e dimensões da malha de elementos finitos. Dados de tomografia de impedância elétrica e imagens de tomografia computadorizada coletados in vivo em um suíno com diferentes alterações fisiológicas pulmonares foram utilizados para validar o algoritmo proposto. As imagens obtidas foram consistentes com os fenômenos de atelectasia, derrame pleural, pneumotórax e variações associadas a diferentes níveis de pressão durante a ventilação mecânica. Os resultados mostram que a reconstrução de imagens de suínos com informação clínica significativa é possível quando tanto o filtro Gaussiano quanto o atlas anatômico são usados como métodos de regularização. / Electrical Impedance Tomography is a non invasive imaging technique that can be used in clinical applications to infer living tissue impeditivity from boundary electrical measurements. Mathematically this is an non-linear ill-posed inverse problem. Usually a spatial high-pass Gaussian filter is used as a regularization method for solving the inverse problem. The main objective of this work is to propose the use of physiological and anatomical priors of tissue resistivity distribution within the thorax, also known as anatomical atlas, in conjunction with the Gaussian filter as regularization methods. The proposed methodology employs the finite element method and the Gauss-Newton algorithm in order to reconstruct three-dimensional resistivity images. The Approximation Error Theory is used to reduce discretization effects and mesh size errors. Electrical impedance tomography data and computed tomography images of physiological pulmonary changes collected in vivo in a swine were used to validate the proposed method. The images obtained are compatible with atelectasis, pneumothorax, pleural effusion and different ventilation pressures during mechanical ventilation. The results show that image reconstruction from swines with clinically significant information is feasible when both the Gaussian filter and the anatomical atlas are used as regularization methods.
189

Arquitetura de aquisição de sinais para tomografia por impedância elétrica. / Signal processing architecture for electrical tomography impedance.

Santos, André Luis dos 30 May 2016 (has links)
Grupos de pesquisa espalhados pelo mundo vêm empregando a Tomografia por Impedância Elétrica (TIE) em aplicações médicas. Entretanto estas pesquisas vem sendo limitadas pelos sistemas de aquisição atualmente empregados, que, frequentemente, n~ao possuem a flexibilidade em termos de números de canais, capacidade de sincronismo temporal e velocidade exigidos nas pesquisas mais recentes. Para facilitar o progresso das pesquisas este trabalho propõe uma arquitetura aberta para aquisição, transferência e armazenamento de sinais. A arquitetura proposta compreende unidades de medição e processamento de sinais, chamadas Canais de Medição. Cada canal de medição é composto por três módulos, o Condicionador de Sinal, o Conversor AD e o Demodulador. Um módulo Supervisor, que essencialmente é um software de configuração e armazenamento, possibilita o controle e monitoramento destes canais através de um módulo Concentrador, que gerencia um barramento de comunicação. Estes módulos, operando em conjunto, têm desempenho equiparável às soluções existentes, porém com ganho de flexibilidade e velocidade. Manutenção e modificações da arquitetura ficam facilitadas pela estrutura modular, aspecto importante nos ambientes de pesquisa. Os dados são armazenados em banco de dados, com a velocidade de coleta compatível com estimação de 50 imagens de TIE por segundo. / Research groups around the world are using Electrical Impedance Tomography (EIT) on medical applications. However investigations are being limited by the acquisition systems, which frequently lack flexibility in terms of the number of channels, temporal synchronism, speed required by recent investigations. To facilitate research progress this work proposes an open architecture for signal acquisition, transfer and storage. The proposed architecture comprises measuring and processing units, called Measuring Channels. Each measuring channel is, in turn, are comprised by three modules, the Signal Conditioner, the AD Converter and the Demodulator. An additional module, called Supervisor, which is essencially an configuration and storage software, allows the monitoring and control of these channels through another additional module, called Concentrator, which manages a communication bus. These modules, working together, have performance equivalent to existing solutions, but with improvements on flexibility and speed. Maintenance and architectural modifications are facilitated due modular structure, important feature in research environment. The data are stored in a database, with data acquisition speed consistent with the estimation of 50 EIT images per second.
190

Desenvolvimento de um software para avaliação de qualidade de imagens tomográficas usando o Phantom Catphan500® / Development of a Software for Image Quality Assessment in Computed Tomography using the Catphan500® Phantom

Vieira, Daniel Vicente 07 October 2016 (has links)
Desde a invenção da tomografia computadorizada (CT) nos anos 70, toda década trouxe novas tecnologias para esta modalidade. Com estes avanços, também surgiu a necessidade de novas e melhores técnicas de avaliação de desempenho e segurança dos equipamentos de CT. Hoje, o controle de qualidade de equipamentos de CT é, em grande parte, feito manualmente. Portanto, é lento e, em parte, subjetivo. Neste trabalho, um software foi escrito em MatLab® para processar imagens do phantom de CT Catphan500®, aperfeiçoando a rotina do programa de controle de qualidade de CT. Com pouca interferência do usuário, o software mede a espessura de corte, incremento entre cortes e tamanho de pixel, avalia a linearidade do número CT, estima a Função Transferência de Modulação (MTF), o ruído e o Espectro de Potência do Ruído (NPS). Para a validação do software, conjuntos de imagens do phantom foram obtidas em 10 equipamentos de CT diferentes, com 27 protocolos diferentes. Cada conjunto foi analisado pelo software, e os resultados obtidos foram comparados aos resultados previamente obtidos pela rotina normal do programa controle de qualidade. Para essa comparação, dois testes de hipótese foram empregados: o teste t de Student (para os valores de espessura de corte, incremento entre cortes, tamanho de pixel e os coeficientes da avaliação de linearidade do número CT, adotando um valor-p de 0,01) e o teste F de Fisher (para o ruído, valor-p de 0,05). As funções MTF e NPS atualmente não são medidas na rotina do controle de qualidade, portanto não há resultado prévio para fazer esta comparação. Ao invés disso, o NPS foi ajustado em função da MTF (através da relação teórica que há entre os dois) e a qualidade do ajuste foi avaliada pelo teste de qui-quadrado. Dos 101 valores de t e 25 valores de F calculados, 2 e 1 respectivamente estavam fora do intervalo de aceitação. Este resultado está de acordo com os valores-p escolhidos e, portanto, os resultados obtidos pelo software estão de acordo com os resultados da rotina de controle de qualidade convencional. Os ajustes de NPS e MTF obtiveram incertezas grandes nos parâmetros de ajuste (incertezas da mesma ordem de grandeza dos próprios parâmetros). Porém, a avaliação do qui-quadrado reduzido indica que os ajustes foram aceitáveis (com exceção de um, que mostrou uma anomalia no NPS medido e foi desconsiderado). Portanto, o NPS e MTF obtidos estão de acordo com a expectativa teórica. / Since the introduction of the CT scanner as a diagnostic imaging modality, the scientific community has seen new and more complex CT technologies. These improvements brought the need for new and improved techniques to evaluate the safety and performance of these scanners. Nowadays, the interpretation of images generated during the implementation of CT quality control procedures are done visually in much of the cases. Therefore, it is slow and partially subjective. In this work, a software was written in MatLab to process images of the Catphan500 CT phantom, in order to improve the CT quality control workflow and its accuracy. The software evaluate the slice thickness, slice increment, and pixel size, calculates the CT number linearity, and assesses the Modulation Transfer Function (MTF), the noise and the Noise Power Spectrum (NPS). Image sets of the phantom were obtained from 10 different scanners using 27 different protocols in order to validate the software. Comparative results correlating the software output and corresponding data previously obtained by the current quality control program routine were used to conduct this validation. For this comparison, two statistical tests were employed: the Students t-test (for slice thickness, slice increment, pixel size, and the coefficients of the CT number linearity evaluation, with a chosen p-value of 0.01) and the Fisher F-test (for the noise, with chosen p-value of 0.05).The functions MTF and NPS are not currently measured by the quality control routine, so there was no previous result for comparison. Instead, the NPS was fitted as a function of the MTF (using the theoretical relationship between both functions) and the quality of the fit was evaluated using the reduced chi-square. From 101 t values and 25 F values calculated, 2 and 1 were outside the acceptance interval, respectively. This result agrees with the chosen p-values, and therefore the software results are in good agreement with the traditional quality control routine results. The fits of NPS and MTF presented large uncertainties in the fitting parameters (uncertainties of the same order of magnitude as the parameters themselves). However, the reduced chi-square evaluation indicates a good fit (with the exception of one fit, which showed an anomaly on the measured NPS and was unconsidered). Therefore, the obtained MTF and NPS were in agreement with the theoretical expectations.

Page generated in 0.0447 seconds