• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1863
  • 23
  • 18
  • 18
  • 16
  • 16
  • 16
  • 10
  • 7
  • 7
  • 7
  • 6
  • 5
  • 4
  • 4
  • Tagged with
  • 1940
  • 1295
  • 1199
  • 806
  • 544
  • 362
  • 351
  • 327
  • 315
  • 248
  • 234
  • 214
  • 198
  • 179
  • 175
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Monitoramento do processo de densificação de compósitos termoestruturais de carbono reforçado com fibras de carbono por tomografia computadorizada e resistividade elétrica

Barbosa, Carlos Alberto Lindholm [UNESP] 06 August 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:32:50Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-08-06Bitstream added on 2014-06-13T21:04:59Z : No. of bitstreams: 1 barbosa_cal_dr_guara.pdf: 2870365 bytes, checksum: d4450badd222b127c86d6a6122ee4eed (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Os compósitos termoestruturais de carbono reforçados com fibras de carbono (CRFC) apresentam propriedades termo-mecânicas adequadas para aplicações a altas temperaturas (1000 a 2800ºC). Estes materiais tem sido utilizados em componentes aeroespaciais, tais como, gargantas de tubeiras de foguete, freios de aeronaves e escudos de reentrada. O processo de manufatura desses materiais, entretanto, é complexo, envolvendo multi-etapas que culminam em uma massa específica adequada com um mínimo de porosidade. O trabalho tem como objetivo correlacionar parâmetros e eficiência de processo como uma ferramenta de controle de qualidade. Compósitos CRFC foram obtidos a partir de preformas tridirecional (3D) e tetradirecional (4D), por meio de sucessivos ciclos iterativos de densificação, que envolveram etapas de impregnação, que correspondem ao preenchimento de poros com resina fenólica, carbonização a 1000ºC e grafitização a 2000ºC. Medidas e cálculos de percentual de vazios ao final de cada etapa de densificação foram realizadas e os resultados comparados com valores teóricos. Análises por difração de raios-X e espectroscopia Raman indicaram que a matriz carbonosa teve sua estrutura cristalina alterada no processo de densificação, quando a temperatura de tratamento térmico muda de 1000 oC para 2000 oC. As etapas de processamento do compósito CRFC foram monitoradas por meio dos ensaios de resistividade elétrica e por tomografia computadorizada de raios-X. A diminuição do volume de porosidade, como conseqüência da incorporação contínua de matriz carbonosa nos compósitos, resultou na diminuição da resistividade elétrica à medida que o número de etapas de processo em direção ao ciclo total de processo. A porosidade medida por tomografia computadorizada revelou valores... / Carbon fiber reinforced carbon matrix (CFRC) exhibits adequate thermomechanical properties for applications at high temperatures (1000-2800 °C). These materials have been used in aerospace components such as rocket nozzle throats, aircraft brakes and reentry shields. However, the manufacturing process of these materials is complex and involves multi-step proceeding which results in an adequate density with a minimum porosity. This work aims to correlate processing parameter and related processing efficiency as a quality control tool. CFRC composites were obtained from multi-directional having three directions (3D) and four directions (4D) by means of successive and iterative cycles involving densification steps by impregnating the performs, which involves the filling of pores with a phenolic resin, carbonization at 1000 °C and graphitization to 2000 °C. Measurements and calculations of percentage of voids at individul processing steps of densification were performed and the results compared with the theoretical values. Analysis by X-ray diffraction analysis and Raman spectroscopy showed that carbonaceous matrix had its crystal structure changed over the densification process, as heat treatment temperature changes from 1000 oC to 2000 oC. The steps of processing of the CFRC composite were monitored by electrical resistivity and by X-ray computed tomography. The decrease in pore volume, as a consequence of the increase in carbon matrix volume fraction in the composites, resulted in a lower electrical resistivity, as the number of processing steps went towards to completion of total processing cycles. The porosity measured by computed tomography reveled values in between 7 and 11% and a bulk density of between 1,16 and 1,20 g/cm3 for the CFRC composites, after the sixtieth step of processing... (Complete abstract click electronic access below)
42

Estabilidade esquelética da multisegmentação maxilar

Mello, Patrícia Bicalho de [UNESP] 22 September 2014 (has links) (PDF)
Made available in DSpace on 2015-06-17T19:34:04Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-09-22. Added 1 bitstream(s) on 2015-06-18T12:47:29Z : No. of bitstreams: 1 000830064.pdf: 746032 bytes, checksum: 77bfdd44b9266c397f03a86531f4d82d (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo desse estudo foi colaborar com o conhecimento atual sobre a estabilidade da multisegmentação maxilar que é controverso na literatura. Foram estudados aspectos relacionados à estabilidade esquelética, verificando-se possíveis relações da instabilidade com a amplitude dos movimentos cirúrgicos realizados, direção dos movimentos cirúrgicos realizados, tempo de acompanhamento e idade. TCFC digitalizadas antes e após cirurgia ortognática com osteotomia maxilar em forma de Y em 3 segmentos de 30 indivíduos em três momentos distintos foram analisadas (T1-pré-cirurgia; T2-pós-cirurgia imediata e T3- mínimo de 11 meses de acompanhamento). Os volumes tomográficos pré e póscirúrgicos foram superpostos, utilizando a base do crânio como referência para todos pacientes. Após a segmentação da maxila foi realizada a quantificação dos deslocamentos entre os modelos nos diferentes momentos por ICP (iterative closest point). Os valores médios dos deslocamentos e seus respectivos intervalos de confiança foram determinados por reamostragem não paramétrica; Man-Whitney para comparações duplas e Kruskal-Wallis para comparações múltiplas. Para as medidas de correlação, o coeficiente de correlação de Spearman foi calculado. Quanto maior a amplitude do deslocamento maior a instabilidade; a correlação da instabilidade com idade e tempo de acompanhamento foram muito pequenas...(Resumo completo, clicar acesso eletrônico abaixo) / The present study was undertaken to collaborate with up to date knowledge about the stability of maxillary multisegmentation that presents itself quite controversially in literature. Aspects related to skeletal stability were studied verifying the possible involvement of instability with the extent and direction of surgical movements performed and age. CBCT scanned before and after orthognathic surgery with maxillary osteotomy Y-shaped in 3 segments of 30 subjects at three different times were analyzed ( T1 - pre-surgery, T2 - immediate post operative and T3 - at least 11 months follow up) . Pre and postoperative CT volumes were superimposed using the base of the skull as a reference for all patients. After segmenting the maxilla, quantification of displacements between models at different moments was performed. The mean values of the desplacements and their respective confidence intervals were determined by nonparametric resampling; Man-Witney for double comparisons and Kruskal-Wallis for multiple comparisons. To measure the correlation, Spearman coefficient was calculated. As the displacement increase the instability increase; the correlation of instability with age and follow-up were very small.
43

Monitoramento do processo de densificação de compósitos termoestruturais de carbono reforçado com fibras de carbono por tomografia computadorizada e resistividade elétrica /

Barbosa, Carlos Alberto Lindholm. January 2012 (has links)
Orientador: Edson Cocchieri Botelho / Coorientador: Luiz Claúdio Pardini / Banca: Michelle Leali Costa / Banca: Choyu Otani / Banca: Antonio Lancelotti Junior / Banca: Maria Luisa Gregori / Resumo: Os compósitos termoestruturais de carbono reforçados com fibras de carbono (CRFC) apresentam propriedades termo-mecânicas adequadas para aplicações a altas temperaturas (1000 a 2800ºC). Estes materiais tem sido utilizados em componentes aeroespaciais, tais como, gargantas de tubeiras de foguete, freios de aeronaves e escudos de reentrada. O processo de manufatura desses materiais, entretanto, é complexo, envolvendo multi-etapas que culminam em uma massa específica adequada com um mínimo de porosidade. O trabalho tem como objetivo correlacionar parâmetros e eficiência de processo como uma ferramenta de controle de qualidade. Compósitos CRFC foram obtidos a partir de preformas tridirecional (3D) e tetradirecional (4D), por meio de sucessivos ciclos iterativos de densificação, que envolveram etapas de impregnação, que correspondem ao preenchimento de poros com resina fenólica, carbonização a 1000ºC e grafitização a 2000ºC. Medidas e cálculos de percentual de vazios ao final de cada etapa de densificação foram realizadas e os resultados comparados com valores teóricos. Análises por difração de raios-X e espectroscopia Raman indicaram que a matriz carbonosa teve sua estrutura cristalina alterada no processo de densificação, quando a temperatura de tratamento térmico muda de 1000 oC para 2000 oC. As etapas de processamento do compósito CRFC foram monitoradas por meio dos ensaios de resistividade elétrica e por tomografia computadorizada de raios-X. A diminuição do volume de porosidade, como conseqüência da incorporação contínua de matriz carbonosa nos compósitos, resultou na diminuição da resistividade elétrica à medida que o número de etapas de processo em direção ao ciclo total de processo. A porosidade medida por tomografia computadorizada revelou valores... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Carbon fiber reinforced carbon matrix (CFRC) exhibits adequate thermomechanical properties for applications at high temperatures (1000-2800 °C). These materials have been used in aerospace components such as rocket nozzle throats, aircraft brakes and reentry shields. However, the manufacturing process of these materials is complex and involves multi-step proceeding which results in an adequate density with a minimum porosity. This work aims to correlate processing parameter and related processing efficiency as a quality control tool. CFRC composites were obtained from multi-directional having three directions (3D) and four directions (4D) by means of successive and iterative cycles involving densification steps by impregnating the performs, which involves the filling of pores with a phenolic resin, carbonization at 1000 °C and graphitization to 2000 °C. Measurements and calculations of percentage of voids at individul processing steps of densification were performed and the results compared with the theoretical values. Analysis by X-ray diffraction analysis and Raman spectroscopy showed that carbonaceous matrix had its crystal structure changed over the densification process, as heat treatment temperature changes from 1000 oC to 2000 oC. The steps of processing of the CFRC composite were monitored by electrical resistivity and by X-ray computed tomography. The decrease in pore volume, as a consequence of the increase in carbon matrix volume fraction in the composites, resulted in a lower electrical resistivity, as the number of processing steps went towards to completion of total processing cycles. The porosity measured by computed tomography reveled values in between 7 and 11% and a bulk density of between 1,16 and 1,20 g/cm3 for the CFRC composites, after the sixtieth step of processing... (Complete abstract click electronic access below) / Doutor
44

Influência dos fatores corneanos no cálculo biométrico para a cirurgia de catarata

Serpe, Crislaine Caroline January 2015 (has links)
Orientador: Prof. Dr. Jorge E. F. Matias / Coorientador: Prof. Dr. Glauco H. Reggiani Mello / Dissertação (mestrado) - Universidade Federal do Paraná, Setor de Ciências da Saúde, Programa de Pós-Graduação em Clínica Cirúrgica. Defesa: Curitiba, 23/01/2015 / Inclui referências / Resumo: Identificar parâmetros corneanos que podem influenciar na precisão do cálculo da lente intraocular na cirurgia de facoemulsificação por microincisão. Estudo observacional prospectivo e comparativo realizado com um total de 71 olhos de 48 pacientes, com catarata, sem comorbidades ou cirurgias oculares prévias. Estes pacientes foram examinados em dois momentos: um no pré-operatório quando foram realizadas a avaliação dos parâmetros corneanos por tomografia de córnea com técnica duplo Scheimpflug (Galilei - Ziemer Ophthalmics System AG, Port, Suíça) e a avaliação biométrica por interferometria óptica (Lenstar LS900 - Haag- Streit Koeniz, Suíça) para o cálculo da lente intraocular; e no segundo momento, em torno de 90 dias de pós-operatório, quando foi realizada a refração subjetiva. Os parâmetros corneanos estudados foram: elevação máxima da esfera de referência BFTA (best-fit toric and aspheric sphere), AAI (asphericity asymmetry Index), coma, distância Kappa, aberração esférica e a presença de assimetrias corneanas leves como as presentes naqueles pacientes suspeitos para ceratocone e analisadas de acordo com o erro preditivo biométrico e o erro absoluto médio do resultado refrativo pós-operatório. Foram realizadas análises estatísticas de acordo com características da amostra e considerado p-valor <0,05 para significância estatística. Na avaliação do desempenho de cada formula biométrica, encontramos os erros preditivos biométricos de: Holladay 0,02D ± 0,42; SRK/T -0,03D ± 0,51; Haigis -0,12D ± 0,41; Hoffer-Q 0,00 ± 0,40D (p-valor = 0,2176). Não foram observados significância estatística na avaliação do erro preditivo biométrico e no erro absoluto médio quanto às assimetrias de elevação corneanas (BFTA e AAI), à distância kappa, à aberração esférica e córneas com leves assimetrias corneanas. Na avaliação do erro preditivo biométrico quanto à assimetria do poder corneano, encontrou-se para coma p-valor = 0,004153 e no erro absoluto, p-valor = 0,022. Houve correlação fraca e negativa pelo teste de correlação linear de Pearson entre as variáveis coma e erro preditivo biométrico (p-valor = 0,007625) (IC 95: -0,5100 a -0,08726). Portanto, identificamos em nosso estudo que, dentre as variáveis tomográficas corneanas avaliadas no préoperatório, a assimetria de poder do tipo coma teve influência na precisão e na variabilidade do cálculo do poder da lente intraocular, com tendência a um resultado miópico pós-operatório. Palavras-chave: assimetrias de córnea, biometria óptica, ceratocone, facoemulsificação, tomografia de córnea. / Abstract: To identify dual Scheimpflug tomographic corneal factors that may influence on the accuracy of intraocular lens power calculation in microincision phacoemulsification, a total of 71 eyes of 48 patients with cataract and without any other ophthalmic disorder were prospectively enrolled and examined at two moments: preoperatively, several corneal and anterior segment variables were obtained by dual Scheimpflug analyzer (GALILEI Analyzer; Ziemer Ophthalmic System AG, Port, Switzerland) and a biometric evaluation was made by optical interferometry (Lenstar LS900 - Haag- Streit Koeniz, Switzerland) for intraocular lens power calculation. The corneal variables were: maximum elevation of best-fit toric and aspheric sphere (BFTA); asphericity asymmetry index (AAI), coma, spherical aberration, Kappa distance and the presence of a keratoconus suspect cornea. Around three months after phacoemulsification, the refractive outcome was compared to the expected result and statistically associated to preoperative corneal variables. Corneal power asymmetry represented by coma increased the mean absolute error (MAE) (P = 0.022), impairing the precision of the intraocular lens power calculation. There was a weak negative correlation between biometric predictive error (BPE) and spherical aberration by the Pearson linear correlation test (P = 0.007625) (IC 95: -0.5100 to - 0.08726). There was no statistical significance when analyzing the other corneal variables analyzed. Thus the coma, a corneal power asymmetry index, is an important corneal factor in the precision of the intraocular lens power calculation. Increased values were correlated to a higher predictive biometric error. Keywords: corneal asymmetry, corneal tomography, phacoemulsification, keratoconus, optical biometry.
45

Avaliação do reparo periapical após cirurgia parendodôntica por meio de radiografia periapical convencional, digital e tomografia computadorizada em feixe /

Jorge, Érica Gouveia. January 2013 (has links)
Orientador: Marcelo Gonçalves / Coorientador: Mário Tanomaru Filho / Banca: Celso Luiz Caldeira / Banca: Rubens Spin-Neto / Banca: Juliane Maria Guerreiro Tanomaru / Banca: Renato de Toledo Leonardo / Resumo:Este estudo teve como objetivos: (1) - avaliar a evolução do reparo ósseo periapical de dentes com lesão periapical após cirurgia parendodôntica, por meio da comparação entre áreas mensuradas em radiografias periapicais convencionais digitalizadas, radiografias periapicais digitais e tomografia computadorizada Cone Beam (CBCT) e (2) - avaliar, em diferentes períodos, o reparo periapical após cirurgia parendodôntica, por meio de mensurações volumétricas em CBCT, e porcentuais, em radiografias periapicais convencionais, digitais e CBCTs. Material e Métodos: Foram selecionados dentes anteriores superiores de 11 pacientes, com rarefação óssea periapical visível radiograficamente e indicação de tratamento cirúrgico. Radiografias periapicais, convencionais e digitais, e CBCTs foram realizadas previamente às cirurgias parendodônticas e após os períodos inicial (48 h), 4 e 8 meses. Para cada período, a área (mm 2 ) de rarefação óssea foi mensurada nas radiografias e comparada com à medida tomográfica na região de maior diâmetro da lesão. As imagens radiográficas foram importadas para o programa ImageJ para delimitação do contorno e cálculo da área radiolúcida periapical. A mensuração das áreas na tomografia, por meio do programa ImageJ, foi realizada nos cortes paralelos ao plano mésio-distal de maior diâmetro da lesão. Para o cálculo de volume, as áreas das rarefações ósseas foram mensuradas nos cortes tomográficos paralelos ao plano sagital de toda extensão da lesão periapical. Em seguida, o volume de cada fatia foi calculado multiplicando a área dos cortes pela distância entre eles. Os valores de área (mm 2 ), obtidos nas radiografias e CBCTs, e volume (mm 3 ), obtidos nas CBCTs, foram utilizados para a comparação e análise do porcentual de reparo ósseo periapical. Os dados foram... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This study was divided into two sections, having as individual objectives: (1) - to evaluate the healing of periapical lesion after endodontic surgery, through the comparison among area values measured in digitized conventional and digital radiographs, and Cone Beam computed tomography (CBCT) and (2) - to evaluate the periapical bone repair over different periods of time after endodontic surgery by volume measured in CBCTs, and by percentage values calculated from the conventional and digital radiographs, and CBCTs. Material and Methods: Eleven maxillary anterior teeth, with the presence of periapical lesion were submitted to root-end filling. Conventional and digital radiographs, and CBCTs were taken prior to the surgeries and after 48 h (baseline), 4 and 8 months. For each period, the area (mm 2 ) of the periapical lesion observed in the radiographs was compared to those of CBCTs. The volume of the lesions, at all stages of evaluation, was calculated using the software ImageJ. The radiographic images were also imported into the ImageJ software, and the area of periapical radiolucency was measured. The area in the CBCTs was obtained based on the slice with the greater mesio-distal diameter of the lesion. To calculate the volume, the area of the periapical lesion of each CBCT slice, in a parallel orientation to the sagittal axis of the entire lesion, was calculated. Then, the volume of each slice was calculated by multiplying the area by the distance between the tomographic slices. The values of area (mm 2 ), measured in the radiographs and CBCTs, and volume (mm 3 ), measured in the CBCTs, were used to calculate the percentage of periapical bone repair. The data were submitted to Analyses of Variance (α=0.05), followed by T-tests. Results: A significant effect was observed among the Periods of Evaluation... (Complete abstract click electronic access below) / Doutor
46

Comparação entre a avaliação radiográfica e a tomográfica do ângulo articular metatarsal distal

Cruz, Eduardo Pedrini January 2015 (has links)
INTRODUÇÃO: O hallux valgus é a deformidade mais comum do pé do adulto e é frequentemente incapacitante requerendo tratamento cirúrgico. O ângulo articular metatarsal distal (AAMD) é uma das variáveis importantes no estudo da deformidade, mas possui baixa correlação interobservadores quando avaliado pela radiografia. O objetivo deste estudo foi avaliar um método tomográfico de aferir este ângulo comparando-o com a medida radiográfica existente. MATERIAL E MÉTODOS: O AAMD de 77 pés (43 pacientes) foi avaliado através de tomografia computadorizada por dois observadores. Os valores encontrados foram comparados entre os observadores e entre a medição radiográfica utilizando o coeficiente de correlação e concordância (CCC) proposto por King e análise de Bland-Altmann para concordância entre os métodos. RESULTADOS: Foi encontrado índice de concordância alto na medição tomográfica entre os observadores com CCC = 0,90 e p < 0,001. Em relação a mensuração radiográfica com a tomográfica houve uma concordância com CCC = 0,667 de com p < 0,001. Na análise gráfica de Bland-Altman a presença de round sign positivo sugere um aumento da diferença da medição radiográfica com a tomográfica e está associado a valor alto do AAMD. CONCLUSÃO: A mensuração do AAMD pelo método tomográfico demonstrou maior correlação interobservadores do que o método radiográfico. Em casos em que há dúvida sobre alteração patológica da inclinação da cabeça metatarsal com ângulos articulares metatarsais distais (AAMD) elevados e, principalmente, com a presença de round sign positivo, a tomografia pode ser um método alternativo para planejamento cirúrgico pré-operatório.
47

Tomografia computadorizada volumétrica : mensuração de tecidos moles gengivais e da mucosa mastigatória do palato e aplicações clínicas

Barriviera, Maurício January 2009 (has links)
Tese (doutorado)—Universidade de Brasília, Faculdade de Ciências da Saúde, 2009. / Submitted by Allan Wanick Motta (allan_wanick@hotmail.com) on 2010-07-21T19:14:06Z No. of bitstreams: 1 2009_MauricioBarriviera_Tese.pdf: 1412114 bytes, checksum: bd1beb010c6816eed539ae500bd0806c (MD5) / Approved for entry into archive by Lucila Saraiva(lucilasaraiva1@gmail.com) on 2010-07-24T02:18:29Z (GMT) No. of bitstreams: 1 2009_MauricioBarriviera_Tese.pdf: 1412114 bytes, checksum: bd1beb010c6816eed539ae500bd0806c (MD5) / Made available in DSpace on 2010-07-24T02:18:29Z (GMT). No. of bitstreams: 1 2009_MauricioBarriviera_Tese.pdf: 1412114 bytes, checksum: bd1beb010c6816eed539ae500bd0806c (MD5) Previous issue date: 2009 / As dimensões e relações das estruturas dento-gengivais sempre foram negligenciadas devido a falta de habilidade para as determinar. O propósito do presente estudo era obter através de tomografia computadorizada volumétrica, imagens de qualidade para visualização de tecidos moles e determinar as dimensões e relações das estruturas dento-gengivais. Duas imagens tomográficas diferentes foram obtidas de três pacientes com biótipos periodontais diferentes. A primeira imagem tomográfica foi obtida seguindo um padrão conhecido mundialmente e a segunda imagem os pacientes tiveram os lábios separados das gengivas através de um afastador de plástico. Com a primeira tomografia foram obtidas as medidas das distâncias da junção esmalte cementária (CEJ) para a crista óssea vestibular e a espessura do osso vestibular. Em contraste, a segunda imagem tomográfica permitiu aferir medidas da distância da margem gengival para a crista óssea vestibular, da margem gengival para a junção esmalte cementária e a largura da gengiva vestibular. A segunda imagem tomográfica permite uma visualização clara das dimensões e análise das relações das estruturas do periodonto e de todo complexo dento-gengival.
48

Avaliação pós-radioterápica de glândulas salivares maiores

Galli, Susane D'Arc Barcelos Britto January 2013 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Ciências da Saúde, Programa de Pós-Graduação em Ciências da Saúde, 2013. / Submitted by Alaíde Gonçalves dos Santos (alaide@unb.br) on 2014-03-17T11:49:28Z No. of bitstreams: 1 2013_SusaneDarcBarcelosBrittoGalli.pdf: 8139144 bytes, checksum: 9f6e793033aa67f4df1faa7cb9b07eb0 (MD5) / Approved for entry into archive by Guimaraes Jacqueline(jacqueline.guimaraes@bce.unb.br) on 2014-03-17T12:53:49Z (GMT) No. of bitstreams: 1 2013_SusaneDarcBarcelosBrittoGalli.pdf: 8139144 bytes, checksum: 9f6e793033aa67f4df1faa7cb9b07eb0 (MD5) / Made available in DSpace on 2014-03-17T12:53:49Z (GMT). No. of bitstreams: 1 2013_SusaneDarcBarcelosBrittoGalli.pdf: 8139144 bytes, checksum: 9f6e793033aa67f4df1faa7cb9b07eb0 (MD5) / Objetivo: Este estudo objetivou avaliar a xerostomia por meio de questionário e objetivamente analisou-se o volume das glândulas salivares maiores pela TC e a função e excreção por meio de cintilografia, antes e após a radioterapia. Materiais e Métodos: Neste estudo prospectivo foram selecionados 28 pacientes, 22 homens e 6 mulheres, com idade que variou entre 18 e 75 anos, com diagnóstico histopatológico de carcinoma espinocelular na região de cabeça e pescoço. Os pacientes foram examinados clínica e radiograficamente para verificar as condições bucais antes da radioterapia. Todos receberam atendimento odontológico. Para avaliar subjetivamente a xerostomia utilizou-se um questionário, a TC para avaliar o volume das glândulas salivares maiores e a cintilografia para análise da função e excreção, antes e após a radioterapia. Resultados: Da aplicação do questionário de xerostomia: foi possível verificar que os respondentes do questionário de xerostomia apresentaram tendência à elevação de seus escores de qualidade de vida ao final do tratamento, quando comparados ao início do tratamento. A elevação dos escores indica a alteração da qualidade de vida, considerada inicialmente como regular passando para ruim ao final do tratamento. Sobre a questão relativa ao gradiente de secura, verificou-se que inicialmente os pacientes classificavam como muito confortável e passaram a sentir, ao final do tratamento, um gradiente de secura moderado. Por fim, em relação ao RTOG ( Radiation Therapy Oncology Group), verificou-se a alteração significativa dos gradientes dos pacientes. Foi possível analisar que inicialmente os pacientes classificaram-se sem alterações, e ao final do tratamento, passaram a classificação para grau II tendendo a grau III. Os exames tomográficos revelaram que ao avaliar as dimensões das glândulas salivares por meio de tomografia, foi possível verificar que, em comparação ao período inicial, houve redução significativa do volume médio das glândulas parótidas e submandibulares (exceto as esquerdas) após o término do tratamento radioterápico. Em relação à função e excreção (exames cintilográficos): ao avaliar a função das glândulas parótidas direita e esquerda foi possível verificar que houve elevação significativa dos escores. Já nas glândulas submandibulares direitas verificou-se que estas passaram de função normal, observada no início do tratamento, para uma disfunção leve. Um comportamento semelhante fora observado nas glândulas submandibulares esquerdas, porém apenas uma tendência à significância estatística. Em relação à excreção, verificou-se que houve uma redução das glândulas, sendo que apenas a glândula submandibular esquerda apresentou redução estatisticamente significativa de sua excreção. Conclusão: Os pacientes apresentaram alterações estatisticamente significativas nas glândulas salivares maiores após a radioterapia conformacional nas três modalidades de análise. Pela facilidade de aplicação do questionário esse estudo propõe como protocolo de atenção ao paciente submetido à radioterapia, no contexto do acompanhamento multidisciplinar antes, durante e depois da radioterapia. _______________________________________________________________________________________ ABSTRACT / Objectives: This study has the aim to evaluate xerostomia, by means of a questionnaire and to objectively analyze the volume of major salivary glands by CT (computerized tomography), and the function and excretion by means of scintigraphy before and after radiotherapy. Materials and Methods: In this prospective study, 28 patients between 18 and 75 years old were selected: 22 men and 6 women, with a histopathologic diagnosis of head and neck squamous cell carcinoma. The patients were clinically and radiographically examined to verify mouth conditions before radiotherapy. All patients received dental treatment. A quantitative analysis of salivary flow was made as well as a subjective analysis of xerostomia, using questionnaires. The CT was used to evaluate the volume of the major salivary glands and the scintigraphy for the analysis of function and excretion before and after radiotherapy. Results: From the xerostomia questionnaire, it was possible to verify that those who answered it showed a tendency of a significant raise of their scores on life quality in the treatment end when compared to the treatment start. The score raise shows the change of life quality, which was initially considered as regular and was bad in the treatment end. In relation to the mouth dryness gradient question, it was verified that, initially, the patients classified it as very comfortable and after as a moderate mouth dryness gradient in the treatment end. Finally, in relation to the RTOG (radiation toxicity group), a significant change was verified in patients’ gradient. It was possible to analyze that, initially, the patients classified themselves as having no changes, and in the end of treatment, they changed their classification to level II, tending to III. The tomographic exams revealed: when evaluating the salivary glands dimensions by means of tomography, it was possible to verify that, in comparison to the initial period, there was a significant reduction of the averages of parotid and submandibular glands (except the left one) after the end of radiotherapy treatment. In relation to function and excretion (scintigraphic exams): when evaluating the function of right and left parotid glands, it was possible to verify that there was a significant score rise. However, in relation to the right submandibular glands, it was verified that these ones changed from normal function, as observed in the treatment start, to light dysfunction. A similar behavior has been observed in the left submandibular glands, although only a tendency to significant statistics was noticed. In relation to excretion, it was verified that there was a tendency to a reduction by the glands, being the left submandibular gland the only one to show that there was a statistically significant reduction of its excretion. Conclusion: The patients showed changes that were statistically significant in major salivary glands after conformational radiotherapy in the three kinds of analysis. Due to the fact that it was easy to apply the questionnaire, this study proposes this questionnaire as a protocol of patient attention to those subjected to the radiotherapy, in the context of multidisciplinary follow-up before, during and after radiotherapy.
49

Método Computacional Baseado em Técnicas Tradicionais e Propriedades Matemáticas para Segmentação de Imagens Pulmonares

França Filho, Cleunio Bezerra de 21 August 2013 (has links)
Submitted by Daniella Sodre (daniella.sodre@ufpe.br) on 2015-03-10T13:20:52Z No. of bitstreams: 2 Dissertaçao Cleunio de França Filho.pdf: 2349406 bytes, checksum: cf1717c01456559aa0c20fad4c2022a8 (MD5) license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) / Made available in DSpace on 2015-03-10T13:20:52Z (GMT). No. of bitstreams: 2 Dissertaçao Cleunio de França Filho.pdf: 2349406 bytes, checksum: cf1717c01456559aa0c20fad4c2022a8 (MD5) license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Previous issue date: 2013-08-21 / A segmentação de imagens é uma tarefa de fundamental importância para o desenvolvimento de soluções baseadas em diagnóstico assistido por computador, com diversas aplicações na análise de imagens médicas. Mais especificamente, estudos que envolvem o processamento de imagens de pulmão têm crescido rapidamente motivados pelo interesse na redução da elevada mortalidade provocada pelas doenças malignas deste órgão. Para aperfeiçoar o desempenho nestas aplicações é importante por um lado realizar medições e mapear adequadamente as caracterizações dos pulmões e de suas anomalias, além de desenvolver técnicas automáticas de processamento das imagens que consigam lidar com restrições de tempo e que eliminem o esforço de radiologistas na segmentação manual das imagens. Diversas abordagens são utilizadas para a segmentação pulmonar, cada uma com vantagens e também deficiências. Este trabalho, em particular, apresenta um algoritmo voltado para a segmentação automática de imagens do pulmão baseado na combinação de técnicas de processamento de imagens coletadas de Tomografia Computadorizada por raio-x com propriedades matemáticas extraídas das imagens de pulmão, as quais servem de base para a estrutura do algoritmo. O trabalho investiga duas técnicas típicas para segmentação de imagens e, a partir da observação do comportamento e desempenho apresentado, é desenvolvido um novo método para a segmentação pulmonar que procura minimizar as deficiências encontradas nos algoritmos investigados. Os experimentos realizados avaliam o desempenho do novo algoritmo, bem como os valores das propriedades matemáticas e dos parâmetros estruturais utilizados ao longo do desenvolvimento do algoritmo, e comparam os resultados dos métodos em relação à sensibilidade, especificidade, acurácia, precisão, f-escore, coeficiente Dice, tempo de processamento e área-perímetro-solidez da região pulmonar segmentada, com o padrão referencial segmentado por um especialista. Os métodos são testados com 1173 imagens reais coletadas de 22 pacientes de um grande hospital e os resultados demonstraram que a combinação de técnicas de processamento de imagens tradicionais com propriedades matemáticas apresenta um desempenho satisfatório para a segmentação pulmonar.
50

Caracterização do MOSFET MOskin para dosimetria em tomografia computadorizada

Pereira, Lenon Mendes 29 May 2015 (has links)
Submitted by Isaac Francisco de Souza Dias (isaac.souzadias@ufpe.br) on 2016-01-19T18:10:45Z No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Lenon Mendes Dissertacao Mestrado 2015.pdf: 3797605 bytes, checksum: 7022202de7a4af31595ea4374ab76da7 (MD5) / Made available in DSpace on 2016-01-19T18:10:45Z (GMT). No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Lenon Mendes Dissertacao Mestrado 2015.pdf: 3797605 bytes, checksum: 7022202de7a4af31595ea4374ab76da7 (MD5) Previous issue date: 2015-05-29 / CAPES / Este trabalho visa caracterizar o MOSkin para dosimetria em tomografia computadorizada. Desta forma, a resposta do detector foi avaliada para as qualidades de referência RQT 8, RQT 9 e RQT 10 e estudos foram realizados para avaliar a sensibilidade, dependência energética, reprodutibilidade, desvanecimento e dependência angular da resposta do dosímetro. Em seguida, o dosímetro foi empregado para avaliação do kerma ar em um tomógrafo Philips Brilliance 6 CT e o seu desempenho foi comparado com o filme radiocrômico Gafchromic XR-CT, dosímetros termoluminescentes TLD-100 e uma câmara de ionização tipo lápis. Os resultados mostraram que a resposta do dosímetro é linear e reprodutível dentro da faixa de dose escolhida (até 7 cGy). Para as energias de feixe avaliadas, o fator de correção para a dependência energética variou no máximo 15% e a dependência angular foi inferior à 7,78% na faixa de 0 a 90º. Assim como esperado, a sensibilidade do dosímetro declinou com o histórico de dose. Para um MOSkin irradiado com a qualidade de feixe RQT 9 (120 kV) a sensibilidade no final da vida útil era 4,76% menor do que a sensibilidade inicial. Porém, com o uso do processo de annealing por pulsos de corrente, foi possível recuperar a resposta do MOSkin, tornando-o reutilizável. Por fim, os resultados obtidos no tomógrafo mostraram que o MOSkin é adequado para obtenção da distribuição do kerma no ar em tomografia computadorizada e para a avaliação da Dose Total Acumulada no Centro. / The aim of this research was to characterize the response of the MOSkin dosimeter for x-ray Computed Tomography beams. The dosimeter’s response was evaluated for standard radiation qualities RQT 8, RQT 9 and RQT 10 and experiments were performed to investigate the sensitivity, energy dependence, reproducibility, fading and angular dependence of the response for the device. The MOSkin was also used for kerma air evaluation in a Philips Brilliance 6 CT unit and a comparison was made with TLD-100 thermoluminescents dosimeters, a radiochromic film Gafchromic XR-CT and a pencil ionization chamber. The results have shown that the MOSkin response was linear and reproducible within the kerma air range used in this research (until 7cGy). Energy dependence correction factors varied up to 15% among the tested x-ray energies. Angular dependence of the dosimeter was not greater than 7.78% within the angle range from 0 to 90 degrees. As expected, the MOSkin sensitivity was found to decline with the dose history. For a MOSkin irradiated at a tube potential of 120 kVp (RQT 9) the sensitivity at its end live was 4.76% smaller than the sensitivity at the beginning of its lifetime. Also, pulsed current annealing was proved to be successful for recovering the threshold voltage and sensitivity. At last, the MOSkin is proved a good alternative for the CT air kerma profile measurements and was adequate for the Total Accumulated Dose assessment.

Page generated in 0.0449 seconds