• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1863
  • 23
  • 18
  • 18
  • 16
  • 16
  • 16
  • 10
  • 7
  • 7
  • 7
  • 6
  • 5
  • 4
  • 4
  • Tagged with
  • 1940
  • 1295
  • 1199
  • 806
  • 544
  • 362
  • 351
  • 327
  • 315
  • 248
  • 234
  • 214
  • 198
  • 179
  • 175
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Desenvolvimento de um traçado computadorizado para a avaliação da articulação temporomandibular em tomografias lineares

Bissoli, Cleber Frigi [UNESP] 31 July 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:10Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-07-31Bitstream added on 2014-06-13T18:46:28Z : No. of bitstreams: 1 bissoli_cf_dr_sjc.pdf: 574993 bytes, checksum: 722460549575ab46d7ffe05076a40a97 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O propósito neste trabalho foi desenvolver um traçado computadorizado para a avaliação da articulação temporomandibular. O estudo foi obtido com uma amostra de 100 tomografias lineares da ATM em que primeiramente foi realizado um traçado manual baseado em traçados já existentes. Foram analisados o ângulo da cabeça da mandíbula, o ângulo interno da eminência articular, a distância da translação da cabeça da mandíbula ao topo da eminência articular, a translação total da cabeça da mandíbula em máxima abertura bucal, além da inclinação da eminência articular e sua inclinação a partir de seu terço inicial. Para a confecção do traçado computadorizado utilizou-se o software Radiocef Studio 2. Encontrou-se uma angulação média de 93 graus para o ângulo da cabeça da mandíbula, 112 graus para o ângulo interno da eminência articular, 10,5 mm para a distância da translação da cabeça da mandíbula ao topo da eminência articular, 14,1 mm a translação total da cabeça da mandíbula em máxima abertura bucal, 33 graus para a inclinação da eminência articular e 23 graus para a inclinação no terço inicial da eminência articular. Posteriormente foi realizado o teste t pareado para a comparação entre os lados direito e esquerdo do indivíduo e entre o traçado manual e computadorizado. Concluiu-se que houve apenas diferença estatisticamente significante entre as inclinações da eminência articular (p=0,001) e para seu terço inicial (p=0,02) entre os lados direito e esquerdo, e que não houve diferença estatisticamente significante entre o traçado manual e o computadorizado, sendo o segundo viável de ser realizado. / The purpose of this study was to develop a computerized tracing in order to evaluate the temporomandibular joint (TMJ). Firstly was obtained a hand-traced based in others from one sample of 100 linear tomographies. Were analyzed the angle of mandibular condyle, the internal angle of articular eminence, the distance between the translation of mandibular condyle and the top of articular eminence, the total translation of mandibular condyle in maximum buccal opening, beyond the inclination of articular eminence. The software Radiocef Studio 2 was used for the computerized tracing`s development. It was found 93 degrees for the mandibular condyle, 112 degrees for the internal angle of the articular eminence, 10,5 mm for the distance between the translation of the condyle and the top of the articular eminence, 14.1 mm the total translation of mandibular condyle in maximum buccal opening, 33 degrees for the inclination of the articular eminence and 23 degrees for the inclination of the articular eminence in the third initial. Later was realized test t paread for the comparison the right and left sides of the individual and between the hand-traced and computerized tracing. It concludes that there was a statistically significant difference among the inclinations of the articular eminence (p=0,001) and the third initial of articular eminence (p=0,02), in the right and the left sides. There was no statistically significant difference between the hand-traced and computerized tracing, being as feasible one.
32

Relação da cabeça da mandíbula na fossa mandibular em indivíduos com más oclusões por meio da tomografia computadorizada volumétrica

Trautmann, Fernanda [UNESP] 25 May 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:29:11Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-05-25Bitstream added on 2014-06-13T19:38:18Z : No. of bitstreams: 1 trautmann_f_me_sjc.pdf: 1282508 bytes, checksum: f1c7cce5513c5a439cf27f0bb563ed86 (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / O propósito deste trabalho foi verificar a posição das cabeças da mandíbula nas suas respectivas fossas mandibulares em individuos com diferentes má-oclusões Classe I, II e III. Foram utilizadas tomografias computadorizadas volumétricas de 60 indivíduos em avaliação préortodôntica do sexo masculino e feminino. Com o gabarito preconizado por Pereira (1997), obtivemos medidas lineares dos espaços articulares anterior, posterior e superior de cada ATM. Após análise estatística, concluiu-se que as cabeças da mandíbula nos casos de Classe III do lado esquerdo apresentaram, com significancia estatística, maior deslocamento anterior em relação a fossa mandibular. Os casos de Classe II do lado esquerdo, embora sem significância estatística, apresentaram tendência de maior deslocamento porterior da cabeça da mandíbula enquanto os grupos de Classe I do mesmo lado apresentaram tendência a posição centralizada. Os grupos de Classe I e III do lado direito apresentaram maior tendência de deslocamento centralizado, enquanto os grupos de.Classe II do mesmo lado apresentaram maior tendência de deslocamento posterior porém sem significância estatística / The purpose of this study was to determine the condyle position in their respective mandibular fossa in different individuals with Class I, II and III malocclusions. Cone Beam Computer Tomographies (CBCT) from 60 male and female individuals were taken in the pre-orthodontic treatment. The answer key developed by Pereira (1997) provides us the linear measurements of the anterior, posterior and superior spaces of TMJ. After statistic analysis, we can conclude that the condyle position in Class III individuals on the left side, showed, with statistical significance, more tendency to anterior condyle dislocation in the mandibular fossa. In Class II cases on the left side, although not statistically significant, tended to posterior condyle deviation position. Class I group on the same side showed a tendency towards central position. Class I and III groups on the right side showed a higher tendency to central position, while Class II groups in the same side showed a higher tendency to posterior position, but without statistical significance
33

Aplicação das tomografias computadorizadas de Raios-X e Gama na análise de Solo Simulado

FONSECA, Alexandra Carolina Gomes da 18 July 2017 (has links)
Submitted by Fernanda Rodrigues de Lima (fernanda.rlima@ufpe.br) on 2018-09-28T19:45:09Z No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) TESE Alexandra Carolina Gomes da Fonseca.pdf: 5722261 bytes, checksum: aac23d8838fdb0e78947a6d85d46b1fb (MD5) / Approved for entry into archive by Alice Araujo (alice.caraujo@ufpe.br) on 2018-11-20T22:57:58Z (GMT) No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) TESE Alexandra Carolina Gomes da Fonseca.pdf: 5722261 bytes, checksum: aac23d8838fdb0e78947a6d85d46b1fb (MD5) / Made available in DSpace on 2018-11-20T22:57:58Z (GMT). No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) TESE Alexandra Carolina Gomes da Fonseca.pdf: 5722261 bytes, checksum: aac23d8838fdb0e78947a6d85d46b1fb (MD5) Previous issue date: 2017-07-18 / CAPES / A aplicação das duas tomografias teve como objetivo o estudo do comportamento do feixe de Raios – X em um fantom de solo tropical, após a filtração adicional e operando em intervalos de tensões entre 100 kV a 225kV. Para esse estudo foram utilizadas duas metodologias amplamente difundidas, que formaram uma metodologia única para a caracterização de materiais minerais do solo. Os equipamentos utilizados foram um micro - CT de Raios – X e um tomógrafo industrial de Raios Gama. Além da parte experimental, o estudo contou com uma fase simulada com os softwares XCOM e SpekCalC, essa fase foi de suma importância porque serviu de referência para as análises dos dados com as duas tomografias. As medições para avaliação da qualidade do feixe foram realizadas com software SpekCalC, as mesmas foram realizadas utilizando os mesmos parâmetros da fase de medidas do tomógrafo de Raios – X, os dados de saída analisados foram camada semi-redutora, energia média, energia efetiva e coeficiente de homogeneidade. Com o tomógrafo de Raios gama foi encontrado dado de intensidade relativa para os materiais puros, e a partir deles foram obtidos os valores de coeficiente de atenuação e densidade dos materiais. Com a técnica de atenuação de Raios – X foram realizadas medidas no fantom do solo e obtidos valores da atenuação de Hounsfield. A junção das metodologias mostrou que a boa resolução de densidade da tomografia de Raios gama foi de suma importância ao longo do estudo, porque indicou as melhorias da fase de construção do fantom, além de indicar os ajustes necessários para fase de medidas. Além da boa resolução temporal e espacial da tomografia de Raios – X, que detém um menor tempo de escaneamento e uma capacidade maior de detalhamento de materiais com dimensões muito pequenas ou particuladas (como os minerais utilizados) devido a sua resolução espacial. / The application of the two tomographies had the objective of studying the behavior of the X - ray beam in a tropical soil phantom, after additional filtration and operating in voltage ranges between 100 kV and 225 kV. For this study, two widely used methodologies were used which formed a unique methodology for the characterization of soil mineral materials. The equipment used was a micro - CT of X - rays and an industrial tomograph of gamma rays. In addition to the experimental part, the study had a simulated phase with the XCOM and SpekCalC softwares this phase was of great importance because it served as reference for the analysis of the data with the two tomographies. Measurements for beam quality evaluation were performed using SpekCalC software, which were performed using the same parameters as the X-ray tomograph measurements, the output data analyzed were semi-red, medium energy, effective energy and coefficient of homogeneity. With the gamma ray tomography, relative intensity data were obtained for the pure materials, and from them the values of the attenuation coefficient and density of the materials were obtained. With the X-ray attenuation technique, measurements were made on soil phantom and Hounsfield attenuation values were obtained. The combination of methodologies showed that the good resolution of gamma ray tomography was of paramount importance during the study because it indicated the improvements of the phantom construction phase, besides indicating the necessary adjustments for the measurement phase. In addition to the good temporal and spatial resolution of X - ray tomography, which has a shorter scanning time and a greater capacity for detailing materials with very small or particulate dimensions (such as the minerals used) due to their spatial resolution.
34

Comparação entre a avaliação radiográfica e a tomográfica do ângulo articular metatarsal distal

Cruz, Eduardo Pedrini January 2015 (has links)
INTRODUÇÃO: O hallux valgus é a deformidade mais comum do pé do adulto e é frequentemente incapacitante requerendo tratamento cirúrgico. O ângulo articular metatarsal distal (AAMD) é uma das variáveis importantes no estudo da deformidade, mas possui baixa correlação interobservadores quando avaliado pela radiografia. O objetivo deste estudo foi avaliar um método tomográfico de aferir este ângulo comparando-o com a medida radiográfica existente. MATERIAL E MÉTODOS: O AAMD de 77 pés (43 pacientes) foi avaliado através de tomografia computadorizada por dois observadores. Os valores encontrados foram comparados entre os observadores e entre a medição radiográfica utilizando o coeficiente de correlação e concordância (CCC) proposto por King e análise de Bland-Altmann para concordância entre os métodos. RESULTADOS: Foi encontrado índice de concordância alto na medição tomográfica entre os observadores com CCC = 0,90 e p < 0,001. Em relação a mensuração radiográfica com a tomográfica houve uma concordância com CCC = 0,667 de com p < 0,001. Na análise gráfica de Bland-Altman a presença de round sign positivo sugere um aumento da diferença da medição radiográfica com a tomográfica e está associado a valor alto do AAMD. CONCLUSÃO: A mensuração do AAMD pelo método tomográfico demonstrou maior correlação interobservadores do que o método radiográfico. Em casos em que há dúvida sobre alteração patológica da inclinação da cabeça metatarsal com ângulos articulares metatarsais distais (AAMD) elevados e, principalmente, com a presença de round sign positivo, a tomografia pode ser um método alternativo para planejamento cirúrgico pré-operatório.
35

Tomografia ultrassônica em concreto

Perlin, Lourenço Panosso January 2011 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Civil, Florianópolis, 2011 / Made available in DSpace on 2012-10-26T02:00:55Z (GMT). No. of bitstreams: 1 291197.pdf: 5731903 bytes, checksum: a2652036a9f0348e1c65fbf72f41df65 (MD5) / Nessa pesquisa efetua-se uma revisão bibliográfica da técnica ultrassônica convencional, demonstrando suas capacidades e limitações na localização de não homogeneidades no concreto. A proposta dessa dissertação é utilizar a técnica tomográfica aplicada com os resultados dos equipamentos já disponíveis para as leituras ultrassônicas no concreto, de modo a melhorar consideravelmente o potencial de visualização dessas não homogeneidades. Para tal, a tomografia também é estudada e adaptada ao uso com o ultrassom. Como é indispensável a utilização de programas de computador para a resolução do problema tomográfico, também nessa pesquisa é efetuada a implementação computacional da tomografia adaptada para o uso do ultrassom. Com o programa TUCon implementado e numericamente verificado, vários ensaios experimentais são executados em corpos de prova de concreto sem armadura e com diferentes não homogeneidades internas conhecidas. Pesquisadores internacionais afirmam que a técnica da tomografia ultrassônica em concreto tem grandes potencialidades para ser utilizada na reconstituição de seções internas de concreto para identificação de não homogeneidades. Através de ensaios experimentais, os resultados dessa dissertação reafirmam tal constatação. / This work presents a review of the ultrasonic pulse velocity method, showing its capacity and limitations for internal flaws identification in plain concrete members. To further improve this ability, the main goal of this work is to use the tomography technique with the results from of conventional ultrasonic equipment already available. Thus, the tomography theory is also presented and adapted to be used with ultrasound equipment. Since is necessary to solve the system of equations yielded by the tomography technique, a software was developed in this work, called TUCon. After TUCon has been numerically checked, several experiments were performed on plain concrete specimens with known internal flaws. International researchers agree that ultrasonic tomography technique has great potential to be used in the reconstitution of internal sections of concrete members and to identify flaws. The experiments performed in this work endorse this statement.
36

Avaliação das alterações transversais imediatas à expansão maxilar com o aparelho quadrihélice por meio de tomografia computadorizada do feixe cônico

Zasso, Manuela Batistella January 2013 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2013. / Made available in DSpace on 2014-08-06T17:39:10Z (GMT). No. of bitstreams: 1 325084.pdf: 1222321 bytes, checksum: 566d4ad956f3872dce1fd2737e54586d (MD5) Previous issue date: 2013 / O objetivo deste estudo clínico prospectivo foi avaliar as alterações esqueléticas transversais imediatas à expansão maxilar lenta (EML) utilizando o aparelho quadrihélice em pacientes com dentição mista através de tomografia computadorizada do feixe cônico (TCFC). Métodos: A amostra consistiu de 27 pacientes com idades entre 7 a 10 anos que utilizaram o aparelho quadrihélice ativado em 8mm e realizaram TCFC antes da instalação dos expansores (T1) e seis meses após (T2). A análise da diferença entre os tempos foi realizada através do teste t de Student para dados pareados, considerando p0,05. Resultados: Na base maxilar não ocorreram mudanças estatisticamente significativas, exceto para a região de molares em vista axial e coronal. Na crista óssea alveolar, todas as variáveis apresentaram aumento estatisticamente significativo (p0,05). Conclusões: A EML utilizando o quadrihélice provocou aumento estatisticamente significativo na base maxilar somente em região de molares, porém clinicamente sem expressão, e aumento transversal da crista óssea alveolar com inclinação dentária. A expansão em nível de crista óssea foi maior que em base maxilar. O quadrihélice não apresentou resultados ortopédicos satisfatórios, mas corrigiu a mordida cruzada em todos os pacientes deste estudo.<br> / Abstract : The purpose of this prospective clinical study was to evaluate the transverse skeletal and dentoalveolar changes immediately slow maxillary expansion ( SME) using the Quad-helix appliance in patients with mixed dentition through beam computed tomography (CBCT ). Methods: A sample of 27 subjects with transverse maxillary deficiency used a quad-helix appliance activated at 8mm, divided into four activations of 2 mm. Cone-beam computed tomography scans were taken before expansion (T1) and six months later (T2). Data were compared by using the Student paired t test to identify statistically significant differences (P<0.05). Results: At the maxillary base there were statistically significant changes, except for the first molar in axial and coronal views. In the alveolar crest, all variables showed a statistically significant increase (p<0.05). Conclusions: The EML using the Quad-helix caused statistically significant increase in the maxillary base at the molar region, but without clinically expression, and presented a transversal increased at the alveolar bone crest with tooth inclination. The expansion in crestal bone level was higher than in maxillary base. The Quad-helix not presented satisfactory orthopedic results, but corrected the crossbite in all patients in this study.
37

Avaliação do uso de membrana de polipropileno na neoformação óssea de alveolo pós-exodontia: um estudo clínico e tomográfico / Evaluation of polypropylene membrane use in bone neoformation post-extraction alveoli: clinical study and tomographic

Sousa, Rodolfo Nunes de 31 October 2016 (has links)
SOUSA, R. N. Avaliação do uso de membrana de polipropileno na neoformação óssea de alveolo pós-exodontia: um estudo clínico e tomográfico. 2016. 61 f. Dissertação (Mestrado em Patologia) - Faculdade de Medicina, Universidade Federal do Ceará, Fortaleza, 2016. / Submitted by Erika Fernandes (erikaleitefernandes@gmail.com) on 2017-01-18T13:18:33Z No. of bitstreams: 1 2016_dis_rnsousa.pdf: 1053665 bytes, checksum: da9e2bd9be052ca3f54e58174d917b1e (MD5) / Approved for entry into archive by Erika Fernandes (erikaleitefernandes@gmail.com) on 2017-01-18T13:18:49Z (GMT) No. of bitstreams: 1 2016_dis_rnsousa.pdf: 1053665 bytes, checksum: da9e2bd9be052ca3f54e58174d917b1e (MD5) / Made available in DSpace on 2017-01-18T13:18:49Z (GMT). No. of bitstreams: 1 2016_dis_rnsousa.pdf: 1053665 bytes, checksum: da9e2bd9be052ca3f54e58174d917b1e (MD5) Previous issue date: 2016-10-31 / The preservation of post-extraction alveolar ridge is one of the challenges of dentistry, especially when rehabilitation claim with endosseous implants. As a result of tooth loss, the residual alveoli tends to reabsorb, creating occasions where there is need for grafting surgery to rehabilitation through supported implant prosthesis. This condition can be prevented, among other techniques, by Guided Bone Regeneration. This study aimed to evaluate the effectiveness of a non-absorbable membrane on bone healing after tooth extraction alveoli sites. A study was conducted with 18 patients requiring extraction, a total of 20 sites, prior to the installation of the implant, which sought care in Face Defects Nucleos the Federal University of Ceará. Was performed prior clinical and radiographic evaluation to surgical procedures, these were divided into two groups: the test group (n = 10) there was installation of non-absorbable membrane, and the control group (n = 10) the membrane was not used. All patients underwent computed tomography cone beam at fifteen and ninety days postoperatively. In both exams vertical and horizontal linear measurements were made through the ImageJ software, post-extraction alveolar center of fifteen and ninety days. It was observed that the retention time in the test group (0.45 ± 0.78) showed if the distance significantly greater than the height of the control group (-2.25 ± 0.97), in which can be seen a significant reduction in bone height (p <0.001). It was noted significant difference in the pattern of variation of the horizontal measured in treated groups with the membrane (0.45 ± 1.92) and control (-1.22 ± 0.49) (p=0,015). The use of non-absorbable membrane did not cause infection, swelling or allergic reaction immunoinflammatory site. The conditions evaluated, clinical and tomographic, noticed a bone maintenance height and widht of fresh alveoli sites can benefit from the installation of endosseous implants. / A preservação do rebordo alveolar pós-exodontia é um dos desafios da Odontologia, principalmente quando há pretensão de reabilitação com implantes endósseos. Em consequência da perda dentária, o alvéolo residual tende a reabsorver, criando ocasiões em que há necessidade de cirurgias de enxertia para reabilitação através de prótese implanto suportada. Essa condição pode ser prevenida, entre outras técnicas, através da Regeneração Óssea Guiada. O presente estudo objetivou avaliar a eficácia de uma membrana não absorvível no reparo ósseo de sítios de alvéolos pós exodontia. Foi realizado um estudo com 18 pacientes necessitando de exodontia (20 sítios cirúrgicos) prévia à instalação de implante, que procuraram atendimento no Núcleo de Defeitos da Face da Universidade Federal do Ceará. Foi realizada avaliação clínica e radiográfica prévia aos procedimentos cirúrgicos, estes foram divididos em dois grupos: no grupo teste (n=10) houve instalação da membrana não absorvível, e no grupo controle (n=10) a membrana não foi usada. Todos os pacientes realizaram tomografia computadorizada de feixe cônico aos quinze e noventa dias de pós-operatório. Em ambos os exames foram realizadas mensurações lineares verticais e horizontais, através do software ImageJ, do centro do alvéolo pós-exodontia de quinze e noventa dias. Observou-se que a manutenção em altura do grupo teste (0,68±0,57) mostrou-se superior à da distância em altura do grupo controle (-2,25±0,97), na qual se pôde perceber redução significativa de perda óssea (p<0.001). Houve diferença significante no padrão de variação da medida horizontal nos grupos tratado com a membrana (0,06±1,20) e controle (-1,22±0,49) (p=0,015). O uso da membrana não absorvível não gerou infecção, inchaço ou reação alérgica imunoinflamatória local. Nas condições avaliadas notou-se de forma clínica e tomográfica uma manutenção óssea em altura de sítios de alvéolos frescos, podendo beneficiar a instalação de implantes endósseos.
38

Comparação entre a avaliação radiográfica e a tomográfica do ângulo articular metatarsal distal

Cruz, Eduardo Pedrini January 2015 (has links)
INTRODUÇÃO: O hallux valgus é a deformidade mais comum do pé do adulto e é frequentemente incapacitante requerendo tratamento cirúrgico. O ângulo articular metatarsal distal (AAMD) é uma das variáveis importantes no estudo da deformidade, mas possui baixa correlação interobservadores quando avaliado pela radiografia. O objetivo deste estudo foi avaliar um método tomográfico de aferir este ângulo comparando-o com a medida radiográfica existente. MATERIAL E MÉTODOS: O AAMD de 77 pés (43 pacientes) foi avaliado através de tomografia computadorizada por dois observadores. Os valores encontrados foram comparados entre os observadores e entre a medição radiográfica utilizando o coeficiente de correlação e concordância (CCC) proposto por King e análise de Bland-Altmann para concordância entre os métodos. RESULTADOS: Foi encontrado índice de concordância alto na medição tomográfica entre os observadores com CCC = 0,90 e p < 0,001. Em relação a mensuração radiográfica com a tomográfica houve uma concordância com CCC = 0,667 de com p < 0,001. Na análise gráfica de Bland-Altman a presença de round sign positivo sugere um aumento da diferença da medição radiográfica com a tomográfica e está associado a valor alto do AAMD. CONCLUSÃO: A mensuração do AAMD pelo método tomográfico demonstrou maior correlação interobservadores do que o método radiográfico. Em casos em que há dúvida sobre alteração patológica da inclinação da cabeça metatarsal com ângulos articulares metatarsais distais (AAMD) elevados e, principalmente, com a presença de round sign positivo, a tomografia pode ser um método alternativo para planejamento cirúrgico pré-operatório.
39

Desmineralização em Osso Trabecular e Osso Cortical de Cães Submetidos à Terapia Com Prednisona.

COSTA, L. A. V. S. 23 March 2011 (has links)
Made available in DSpace on 2016-08-29T15:37:21Z (GMT). No. of bitstreams: 1 tese_4728_.pdf: 555220 bytes, checksum: 6bd911bdddf7c8e1947d1e12d81e07d5 (MD5) Previous issue date: 2011-03-23 / Os glicocorticóides são farmacos amplamente utilizados em medicina veterinária, seu emprego pode desencadear uma série de efeitos adversos. O ensaio clínico realizado teve como objetivo a avaliação das possíveis alterações na densidade mineral óssea após a terapia com prednisona, utilizando a tomografia computadorizada helicoidal. No estudo, foram utilizados oito cães hígidos sem raça definida, adulto-jovens, sendo 4 machos e 4 fêmeas. A prednisona foi administrada por via oral aos animais na dose diária de 2mg kg-1 de peso durante 30 dias. A densidade mineral óssea foi determinada a partir da obtenção de valores de radiodensidade da região de osso cortical e osso trabecular do corpo vertebral da segunda vértebra lombar, imediatamente após o período da administração do medicamento. O protocolo experimental permitiu a caracterização significativa (P<0,05) diminuição da radiodensidade do osso trabecular do corpo vertebral da segunda vértebra lombar, entretanto não se constatou desmineralização significativa na região cortical. Nenhum dos cães do grupo experimental apresentou fratura patológica ao término da administração do medicamento. Comprovou-se que as alterações no metabolismo ósseo de cães submetidos à terapia com prednisona na dose de 2mg kg-1 ocorrem precocemente apenas em osso trabecular, tornando-se recomendado monitoramento dos pacientes para prevenção de fraturas patológicas.
40

Avaliação do reparo periapical após cirurgia parendodôntica por meio de radiografia periapical convencional, digital e tomografia computadorizada em feixe

Jorge, Érica Gouveia [UNESP] 12 March 2013 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:33Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-03-12Bitstream added on 2014-06-13T19:41:52Z : No. of bitstreams: 1 jorge_eg_dr_arafo_parcial.pdf: 228397 bytes, checksum: 7fd4a09ffeb7d4881dcc794270ae8361 (MD5) Bitstreams deleted on 2015-06-25T13:01:04Z: jorge_eg_dr_arafo_parcial.pdf,. Added 1 bitstream(s) on 2015-06-25T13:03:24Z : No. of bitstreams: 1 000718680_20160312.pdf: 206271 bytes, checksum: 74de041b3b2b5333623f8ae23c35b272 (MD5) Bitstreams deleted on 2016-03-14T11:16:20Z: 000718680_20160312.pdf,. Added 1 bitstream(s) on 2016-03-14T11:17:03Z : No. of bitstreams: 1 000718680.pdf: 848471 bytes, checksum: 4aabc45470eacf0e09cd93b63cbe4f22 (MD5) / This study was divided into two sections, having as individual objectives: (1) - to evaluate the healing of periapical lesion after endodontic surgery, through the comparison among area values measured in digitized conventional and digital radiographs, and Cone Beam computed tomography (CBCT) and (2) - to evaluate the periapical bone repair over different periods of time after endodontic surgery by volume measured in CBCTs, and by percentage values calculated from the conventional and digital radiographs, and CBCTs. Material and Methods: Eleven maxillary anterior teeth, with the presence of periapical lesion were submitted to root-end filling. Conventional and digital radiographs, and CBCTs were taken prior to the surgeries and after 48 h (baseline), 4 and 8 months. For each period, the area (mm 2 ) of the periapical lesion observed in the radiographs was compared to those of CBCTs. The volume of the lesions, at all stages of evaluation, was calculated using the software ImageJ. The radiographic images were also imported into the ImageJ software, and the area of periapical radiolucency was measured. The area in the CBCTs was obtained based on the slice with the greater mesio-distal diameter of the lesion. To calculate the volume, the area of the periapical lesion of each CBCT slice, in a parallel orientation to the sagittal axis of the entire lesion, was calculated. Then, the volume of each slice was calculated by multiplying the area by the distance between the tomographic slices. The values of area (mm 2 ), measured in the radiographs and CBCTs, and volume (mm 3 ), measured in the CBCTs, were used to calculate the percentage of periapical bone repair. The data were submitted to Analyses of Variance (α=0.05), followed by T-tests. Results: A significant effect was observed among the Periods of Evaluation... (Complete abstract click electronic access below)

Page generated in 0.5837 seconds