• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 74
  • 25
  • 7
  • 4
  • 3
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 114
  • 114
  • 63
  • 57
  • 26
  • 16
  • 14
  • 12
  • 11
  • 10
  • 10
  • 9
  • 9
  • 9
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
81

Avaliação da relação entre as raízes dos dentes posteriores e o assoalho do seio maxilar em pessoas sem e com fissura labiopalatina

Pagin, Otávio 10 August 2015 (has links)
O seio maxilar apresenta formato distinto e volume variável entre as pessoas e seu assoalho pode ser encontrado em íntimo contato com as raízes dos dentes posteriores, podendo haver protrusão dessas raízes em seu interior. Tal proximidade é de grande relevância frente aos casos de comunicação bucossinusal em potencial ou pela possibilidade de desenvolvimento de um quadro infeccioso de origem odontogênica, em que esse pode vir a se estender para o interior do seio maxilar. Existe uma ausência de trabalhos na literatura acerca da relação estabelecida entre dentes posteriores e o seio maxilar em pessoas com fissura labiopalatina. O objetivo do presente estudo foi identificar e comparar a relação entre o assoalho do seio maxilar e os ápices radiculares dos dentes posteriores em imagens de tomografia computadorizada de feixe cônico em pessoas sem fissura labiopalatina e com fissura transforame incisivo unilateral e bilateral. Foram avaliados 100 indivíduos sem anomalias craniofaciais e 112 com fissura transforame incisivo unilateral ou bilateral, não sindrômicos, utilizando o programa i-CAT® Vision, onde a relação estabelecida pelas estruturas foi convencionada sendo, tipo 0 ou ausência de contato entre as estruturas, tipo 1 ou relação de íntimo contato entre as estruturas sem protrusão radicular no interior do seio maxilar e tipo 2 ou relação de íntimo contato entre as estruturas com protrusão radicular no interior do seio maxilar. Foi utilizado o teste do qui-quadrado para comparar os achados entre os grupos estudados, considerando valor estatisticamente significante quando p≤ 0,05. Foi avaliada a relação do assoalho do seio maxilar com 1679 dentes, totalizando 3664 raízes onde 1883 (51,3%) foram classificadas como tipo 0, 1456 (39,7%) tipo 1 e 325 (8,8%) do tipo 2. Houve diferença estatisticamente significante para a raiz palatina do dente 18 entre os grupos com fissura unilateral e bilateral (p = 0,011), para a raiz mesiovestibular do dente 18 entre os grupos sem fissura e fissura bilateral (p = 0,046), bem como entre os grupos com fissura unilateral e bilateral (p = 0,016) e para a raiz vestibular do dente 24 entre os grupos sem fissura e com fissura bilateral (p = 0,001). Pessoas com fissura transforame incisivo unilateral e bilateral tendem a apresentar maior ocorrência da raiz vestibular do dente 24 (p = 0,027) e mesiovestibular do dente 16 (p = 0,047) em proximidade com o seio maxilar quando comparadas às pessoas sem fissura. Pessoas com fissura transforame incisivo bilateral tendem a apresentar uma maior ocorrência de proximidade com o seio maxilar das raízes vestibular do dente 24 (p = 0,001) e mesiovestibular do dente 18 (p = 0,046) quando comparados às pessoas sem fissura. A avaliação das raízes dos dentes posteriores por meio de imagens de tomografia computadorizada de feixe cônico e sua relação com o seio maxilar oferecem detalhamento e precisão, contribuindo assim para a elaboração de um diagnóstico e plano de tratamento que visam minimizar os riscos de acidentes e complicações. / The maxillary sinus has a remarkable feature and a variable volume among people where the inferior wall may be found in an intimate relation with the posterior teeth roots protruding or not inside the antrum. This proximity is of great relevance considering a potential oroantral communication or the spreading of an odontogenic infection into the maxillary sinus. There is a lack of evidence into the literature regarding the relationship between posterior teeth roots and the maxillary sinus in non-syndromic complete cleft lip and palate patients. This study aimed to evaluate and compare cone beam computed tomography images regarding the relationship between the posterior teeth roots and the maxillary sinus floor in non-cleft lip and palate patients and non-syndromic complete unilateral and bilateral cleft lip and palate patients. Images were interpreted using the i-CAT® Vision software including 100 noncleft patients and 112 presenting non-syndromic complete unilateral and bilateral cleft lip and palate. The relationship between teeth roots and the maxillary sinus floor was established as type 0 or no contact between these structures, type 1 or close contact without root protrusion into the sinus and type 2 or close contact with root protrusion into the sinus. The chi-square test, considering a statistically significant value where p≤0,05, was used to compare data between different groups. The sample included 1679 teeth and 3664 roots where 1883 (51,3%) were classified as type 0, 1456 (39,7%) as type 1 and 325 (8,8%) as type 2. There were statistically significant differences for tooth 18 palatine root between both complete cleft lip and palate groups (p = 0,011), for tooth 18 mesiobuccal root between noncleft and the bilateral groups (p = 0,046) and between both complete cleft lip and palate groups (p = 0,016) and for tooth 24 buccal root between non-cleft and the bilateral group (p = 0,001). Complete unilateral and bilateral cleft lip and palate patients presented a higher occurrence when compared with the non-cleft group of the tooth 24 buccal root (p = 0,027) and the tooth 16 mesiobuccal root (p = 0,047) in proximity with the maxillary sinus. Complete bilateral cleft lip and palate patients had a higher occurrence when compared with the non-cleft group of the tooth 24 buccal root (p = 0,001) and the tooth 18 mesiobuccal root (p = 0,046) in proximity with the sinus floor. The posterior teeth roots relationship with the maxillary sinus floor is better depicted and accurate by cone beam computed tomography images that may collaborated for a diagnosis and treatment planning that reduces the risks.
82

Viabilidade da substituição de raízes de dentes humanos por raízes construídas em compósito para estudos de mecânica da fratura / Viability of replacing the roots of human teeth by roots made of composite for the study of fracture mechanics

Espósito, Camila Oliveira Moraes 27 April 2012 (has links)
OBJETIVO: A restauração de dentes tratados endodonticamente é um desafio para a Odontologia. A fratura do remanescente radicular é comum neste tratamento. São três os métodos utilizados para estudar as fraturas: a análise por elementos finitos, os que utilizam dentes naturais e aqueles que utilizam dentes artificiais. O uso de dentes naturais apresenta alguns inconvenientes, como as variações anatômicas e de histórico de exposição a esforços (que aumentam a variabilidade da amostra e dificultam as conclusões), além da pequena disponibilidade de espécimes. Este estudo propõe-se avaliar a viabilidade de usar compósito para a construção de raízes artificiais e a aplicação dessas réplicas em estudos sobre a essas fraturas. MÉTODOS: Na primeira etapa foram utilizadas 50 raízes unirradiculares de 2º pré-molar superior e 50 réplicas. As raízes naturais foram selecionadas por terem características anatômicas semelhantes. As réplicas foram confeccionadas a partir de um molde de resina acrílica que copiou uma raiz natural com proporções dentro da média. O compósito foi escolhido pelas propriedades mecânicas mais próximas das propriedades mecânicas da dentina. Todas as raízes e as réplicas foram submetidas a forças compressivas de uma ponta metálica cônica (simulação do pino intrarradicular), até a fratura. A velocidade de avanço da ponta foi de 5mm/min. Na segunda etapa, foram confeccionadas 30 réplicas, divididas em 3 grupos (n=10). Todas foram restauradas com pinos metálicos fundidos e coroas metálicas. No grupo FZ os pinos foram cimentados com fosfato de zinco; no grupo CRD foi aplicada uma camada de vaselina sólida no conduto radicular e os pinos foram cimentados com cimento resinoso dual; no grupo CRC foi feita aplicação de um agente de união no conduto radicular e os pinos foram cimentados com cimento resinoso dual. Os espécimes foram submetidas a ciclagem mecânica de 130.000 ciclos sob pressão de 5bar. Duas raízes de cada grupo foram utilizadas para testar os parâmetros do ensaio de resistência à fratura. Em seguida, as outras raízes (n=8) foram submetidas ao teste de resistência sob forças compressivas até a ruptura. A carga foi aplicada com inclinação de 20º e velocidade de 5mm/min. RESULTADOS: Na comparação entre a resistência das raízes naturais e artificiais à penetração de pino no conduto radicular, houve diferença estatística entre os dois grupos. As raízes artificiais apresentam maior resistência à fratura (115,4MPa) do que as raízes naturais (75,4MPa). O coeficiente de variação das réplicas (21%) é menor que o das raízes naturais (36,3%), o que indica uma menor variabilidade da amostra das réplicas. Mesmo com valores diferentes, há semelhança na direção do traço de fratura e no local onde ocorrem. Esse resultado indica que a concentração de tensões e a propagação da fratura é semelhante em dentina e compósito. Quanto às réplicas restauradas com pinos, não houve diferença estatística entre os grupos. CONCLUSÃO: As raízes artificiais quando comparadas as raízes naturais, apresentam maior resistência à fratura, menor variação dos resultados individuais em torno da média e modo de fratura semelhante às raízes naturais. Desta maneira, é viável a utilização das réplicas nos estudos sobre mecânica da fratura. / OBJECTIVE: The restoration of endodontically treated teeth is a challenge for dentistry. The fracture of the remaining root is common in this treatment. There are three methods used to study fractures: a finite element analysis, using the natural teeth and those who use artificial teeth. The use of natural teeth has some disadvantages, such as anatomical variations and a history of exposure to stresses (which increase the variability of the sample and the findings difficult), beyond the limited availability of specimens. This study aims to evaluate the feasibility of using composite for the construction of artificial roots and application of these replicas in studies of these fractures. METHODS: In the first stage were used 50 single-rooted roots of 2nd premolar and 50 replicas. The natural roots were selected for having similar anatomical features. The replicas were made from an acrylic resin such that a natural root copied with ratios in the average. The composite was selected by the mechanical properties closer to the mechanical properties of the dentin. All the roots and the replicas were subjected to compressive forces of a conical metal tip (simulation post) until failure. The feed rate was tip of 5mm/min. In the second step, 30 replicas were prepared, divided into 3 groups (n = 10). All were filled with molten metal pins and metal crowns. In group A the posts were cemented with zinc phosphate, group B was applied to a solid layer of vaseline in the root canal and the posts were cemented with dual resin cement, in group C was made applying a bonding agent in the root canal and the posts were cemented with dual resin cement. The specimens were subjected to mechanical loading of 130,000 cycles under a pressure of 5bar. Two roots from each group were used to test the parameters of fracture toughness test. Then the other root (n = 8) were subjected to endurance test under compressive forces until failure. The load was applied with an inclination of 20° and speed 5mm/min. RESULTS: Comparing the resistance of natural and artificial root penetration of the pin in the root canal, was no statistical difference between the two groups. The artificial roots showed higher fracture strength (115.4 MPa) than the natural roots (75.4 MPa). The coefficient of variation of the replicas (21%) is less than the natural root (36.3%), indicating a lower variability of the replicas of the sample. Even with different values, there are similarities in the direction of the fracture site and where they occur. This result indicates that the stress concentration and fracture propagation is similar in dentin and composite. As for replicas restored with posts, no statistical difference between groups was found. CONCLUSION: The artificial roots showed greater resistance to fracture when compared to natural roots, less variation of individual results around the mean and mode of fracture similar to the natural roots. Thus, it is feasible to use in studies of replicas of fracture mechanics.
83

Estudo in vitro da perfuração radicular por diferentes diâmetros de mini-implantes / In vitro study of root perforation by different mini-implant diameters

Roberto Bombonatti 07 November 2014 (has links)
Este trabalho teve como objetivo avaliar o torque e a carga axial de inserção e a severidade das lesões radiculares em dentes humanos decorrentes da utilização de diferentes diâmetros de mini-implantes com finalidade ortodôntica. Sessenta pré-molares extraídos foram inclusos em osso artificial e divididos em 3 grupos, correspondentes a 3 diferentes diâmetros de mini-implante (1,4mm, 1,6mm e 1,8mm). Em cada raiz dentária foram inseridos manualmente 2 mini-implantes autoperfurantes utilizando dois métodos de inserção (com e sem perfuração prévia inicial com fresa) e em duas alturas (apical e cervical). Quinze mini-implantes foram inseridos apenas em osso artificial como parâmetro de comparação. Foram quantificados o torque e a carga axial de inserção através de um torquímetro axial digital e uma célula de carga respectivamente. Os dentes foram, então, escaneados e analisados através de microtomografia computadorizada (Micro-CT) a fim de se observar as severidades das lesões radiculares provocadas pelos mini-implantes. Os dados referentes ao torque e à carga axial dos mini-implantes inseridos em pré-molares foram submetidos à análise de variância (ANOVA) a três critérios, sendo aplicados posteriormente testes de Tukey para comparação entre os grupos. A diferença dos torques e das cargas axiais entre os mini-implantes inseridos no osso artificial e nas raízes dentárias foi estimada por testes t. Foram aplicados também testes de Qui-Quadrado para avaliar as severidades das lesões radiculares. Tanto os torques como as cargas axiais de inserção dos mini-implantes inseridos em raízes de dentes humanos apresentaram diferenças estatisticamente significantes entre os diferentes diâmetros avaliados, porém sem um padrão definido. Os miniimplantes inseridos nas raízes apresentaram valores maiores estatisticamente significantes do que os inseridos em osso artificial somente em relação à carga axial. As lesões radiculares de dentes humanos decorrentes dos mini-implantes se tornaram mais severas estatisticamente com a perfuração prévia inicial ao procedimento de inserção. / The aim of this study was to evaluate placement torque, axial placement load and severity of root lesions in human teeth caused by different diameters of orthodontic mini-implants. Sixty extracted premolars were included in artificial bone and divided into three groups according to different mini-implant diameters (1.4mm, 1.6mm and 1.8mm). Two self-drilling mini-implants were manually inserted into each root using two placement methods (with and without initial pre-drilling) in the apical and cervical regions. Fifteen mini-implants were inserted into artificial bone as a comparison parameter. Placement torque and axial placement load were quantified by a digital torquimeter and a load cell, respectively. The teeth were scanned and analyzed with microcomputed tomography (Micro-CT) to observe the severity of root lesions caused by the mini-implants. The torque and the axial load of mini-implants inserted into premolars were analyzed by 3-way analysis of variance (ANOVA), followed by Tukey tests. Differences in the torques and axial loads between the mini-implants inserted in dental roots and artificial bone were compared with t tests. Chi-square tests were applied to assess the severity of root lesions. The placement torques and the axial placement loads of mini-implants inserted into human dental roots showed significant differences between the different diameters evaluated, but with no standardized effect. Mini-implants inserted into the roots showed significantly higher axial placement load values than those inserted into artificial bone. The root lesions of human teeth caused by mini-implants became statistically more severe with initial pre-drilling.
84

Estudo in vitro da perfuração radicular por diferentes diâmetros de mini-implantes / In vitro study of root perforation by different mini-implant diameters

Bombonatti, Roberto 07 November 2014 (has links)
Este trabalho teve como objetivo avaliar o torque e a carga axial de inserção e a severidade das lesões radiculares em dentes humanos decorrentes da utilização de diferentes diâmetros de mini-implantes com finalidade ortodôntica. Sessenta pré-molares extraídos foram inclusos em osso artificial e divididos em 3 grupos, correspondentes a 3 diferentes diâmetros de mini-implante (1,4mm, 1,6mm e 1,8mm). Em cada raiz dentária foram inseridos manualmente 2 mini-implantes autoperfurantes utilizando dois métodos de inserção (com e sem perfuração prévia inicial com fresa) e em duas alturas (apical e cervical). Quinze mini-implantes foram inseridos apenas em osso artificial como parâmetro de comparação. Foram quantificados o torque e a carga axial de inserção através de um torquímetro axial digital e uma célula de carga respectivamente. Os dentes foram, então, escaneados e analisados através de microtomografia computadorizada (Micro-CT) a fim de se observar as severidades das lesões radiculares provocadas pelos mini-implantes. Os dados referentes ao torque e à carga axial dos mini-implantes inseridos em pré-molares foram submetidos à análise de variância (ANOVA) a três critérios, sendo aplicados posteriormente testes de Tukey para comparação entre os grupos. A diferença dos torques e das cargas axiais entre os mini-implantes inseridos no osso artificial e nas raízes dentárias foi estimada por testes t. Foram aplicados também testes de Qui-Quadrado para avaliar as severidades das lesões radiculares. Tanto os torques como as cargas axiais de inserção dos mini-implantes inseridos em raízes de dentes humanos apresentaram diferenças estatisticamente significantes entre os diferentes diâmetros avaliados, porém sem um padrão definido. Os miniimplantes inseridos nas raízes apresentaram valores maiores estatisticamente significantes do que os inseridos em osso artificial somente em relação à carga axial. As lesões radiculares de dentes humanos decorrentes dos mini-implantes se tornaram mais severas estatisticamente com a perfuração prévia inicial ao procedimento de inserção. / The aim of this study was to evaluate placement torque, axial placement load and severity of root lesions in human teeth caused by different diameters of orthodontic mini-implants. Sixty extracted premolars were included in artificial bone and divided into three groups according to different mini-implant diameters (1.4mm, 1.6mm and 1.8mm). Two self-drilling mini-implants were manually inserted into each root using two placement methods (with and without initial pre-drilling) in the apical and cervical regions. Fifteen mini-implants were inserted into artificial bone as a comparison parameter. Placement torque and axial placement load were quantified by a digital torquimeter and a load cell, respectively. The teeth were scanned and analyzed with microcomputed tomography (Micro-CT) to observe the severity of root lesions caused by the mini-implants. The torque and the axial load of mini-implants inserted into premolars were analyzed by 3-way analysis of variance (ANOVA), followed by Tukey tests. Differences in the torques and axial loads between the mini-implants inserted in dental roots and artificial bone were compared with t tests. Chi-square tests were applied to assess the severity of root lesions. The placement torques and the axial placement loads of mini-implants inserted into human dental roots showed significant differences between the different diameters evaluated, but with no standardized effect. Mini-implants inserted into the roots showed significantly higher axial placement load values than those inserted into artificial bone. The root lesions of human teeth caused by mini-implants became statistically more severe with initial pre-drilling.
85

A cone-beam computerized tomography evaluation of anterior root resorption comparing SureSmile® and conventional edgewise treatments

Patel, Neepa. January 2009 (has links) (PDF)
Thesis--University of Oklahoma. / Bibliography: leaves 120-128.
86

Untersuchungen zum Einfluss radialer Schmierölbohrungen auf die Zahnfußtragfähigkeit außenverzahnter Stirnräder

Liebig, Thomas 18 June 2015 (has links) (PDF)
Die Arbeit untersucht den Einfluss von von radialen, im Zahngrund auslaufenden Schmierölbohrungen auf die Zahnfußtragfähigkeit außenverzahnter Stirnräder durch theoretische und experimentelle Untersuchungen. Es werden Formeln entwickelt, die ohne zeitaufwändige Berechnungen eine sichere Beurteilung des Einflusses von Schmierölbohrungen auf die Zahnfußtragfähigkeit ermöglichen. Dazu wird ein Einflussfaktor Y_OeB ermittelt, welcher die einfache Integration in vorhandene Berechnungsstandards erlaubt. Als Vorlage dient dabei die Berechnung der Zahnfußtragfähigkeit nach DIN 3990 / ISO 6336, die durch diesen Faktor ergänzt werden kann. Neben experimentellen Versuchen zum Einfluss der geometrischen Größen Zahnfußausrundungsradius und Bohrungsdurchmesser werden auch verschiedene Parameter wie die Kranzdicke, zusätzliche Torsionsbelastungen (z. B. an Sonnenwellen), die Wärmebehandlung und die Belastungsart (Schwell- oder Wechsellast) berücksichtigt. Darüber hinaus betrachtet die Arbeit das Verhalten verschiedener Werkstoffe bei Vorhandensein einer Schmierölbohrung. Sie liefert des Weiteren einen Erklärungsansatz zum Einfluss der Schmierölbohrungen auf die Zahnfußtragfähigkeit auf Basis der Veränderung der Eigenspannungsverteilung im Zahnfußgebiet durch die radiale Bohrung und bietet dafür auch ein Modell zur qualitativen Berechnung der Eigenspannungsverteilung auf Basis der FE-Methode an.
87

Möglichkeiten und Grenzen asymmetrischer Kegelradverzahnungen

Schumann, Stefan 18 June 2015 (has links) (PDF)
Durch neue, hochflexible Fertigungsverfahren wie das Freiformfräsen eröffnet sich für Kegelradverzahnungen ein großes geometrisches Optimierungspotenzial. Diese Arbeit widmet sich daher der Ermittlung einer optimalen Makro-, Mikro- und Zahnfußgeometrie für bogenverzahnte Kegelräder. Neben dem Zahnprofil und der Zahnfußkurve wird besonderes Augenmerk auf die Ermittlung topologischer Flankenmodifikationen zur Maximierung der Tragfähigkeit gelegt. Gleichzeitig bietet der gezeigte Optimierungsalgorithmus die Möglichkeit zur Minimierung der Geräuschanregung, wodurch der bisher existierende Zielkonflikt zwischen diesen beiden Aspekten aufgehoben werden kann.
88

An in vitro comparison of working length accuracy between a digital system and conventional film when vertical angulation of the object is variable

Christensen, Shane R. January 2009 (has links)
Thesis (M.S.D.)--Indiana University School of Dentistry, 2009. / Title from PDF t. p. (viewed Aug. 21, 2009) Advisor(s): Mychel Vail, Acting Chair of the Research Committee, Joseph Legan, Kenneth Spolnik, Susan L. Zunt, Edwin Parks. Curriculum vitae. Includes abstract. Includes bibliographical references (leaves 109-120).
89

Estudo in vitro da resistência à fratura de raízes debilitadas. Efeito de diferentes tratamentos restauradores

Ueda, Julio Katuhide [UNESP] 06 November 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:26Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-11-06Bitstream added on 2014-06-13T19:41:14Z : No. of bitstreams: 1 ueda_jk_dr_arafo.pdf: 3962196 bytes, checksum: a5332fed2f0a6d42be6d3100aaa4ce11 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A preservação e a restauração de dentes despolpados severamente debilitados é um procedimento complexo e relativamente imprevisível. Este estudo avaliou a resistência à fratura de raízes bovinas experimentalmente debilitadas, reconstruídas internamente com diferentes materiais restauradores em combinação com pinos pré-fabricados de fibra de vidro comparados com raízes íntegras restauradas com núcleo metálico fundido ou pino de fibra de vidro. Foram selecionadas raízes de 120 (n=15) incisivos bovinos inferiores de dimensões semelhantes, dos quais, 90 foram internamente preparados para simular uma raiz debilitada. Todas as raízes foram preenchidas com diferentes materiais restauradores e os espécimes foram submetidos ao teste de resistência ao fracasso/ fratura com a aplicação de uma carga compressiva tangencial a um ângulo de 135º em relação ao longo eixo axial das raízes. Resultados indicaram diferenças estatisticamente significante entre os grupos. As raízes debilitadas restauradas com núcleo metálico fundido (grupo NMF-RD) demonstraram os mais baixos valores de resistência à fratura (107.7436 N), sendo estatisticamente diferentes dos demais grupos. As raízes íntegras restauradas com núcleo metálico fundido (NMF-RI) mostraram os maiores valores de resistência (362.3308 N), mas com diferenças estatisticamente significantes somente quando comparadas às raízes debilitadas restauradas com cimento resinoso dual (Variolink II, Ivoclar Vivadent - grupo Vario-RD), cimento resinoso autopolimerizável (Multilink, Ivoclar Vivadent - grupo Multi-RD) e cimento de ionômero de vidro modificado por resina (Vitremer, 3M ESPE - grupo Vitre-RD) associado com pino de fibra de vidro... / The preservation and restoration of severely weakened pulpless teeth is a difficult and relatively unpredictable procedure. This study evaluated the resistance to fracture of experimentally weakened bovine roots internally reconstructed with different filling materials in combination with prefabricated fiberglass posts compared with restored roots that were relatively intact. The roots of 120 mandibular bovine incisors with similar bulks were selected. Of these, 90 were internally prepared to standardized dimensions, thereby simulating weakness. All roots were filled with different restorative materials. The specimens were submitted to the fracture resistance testing with the application of a tangential compressive loading at an angle of 135º in relation to the long axes of the roots. Results indicated statistically significant differences among the groups. The weakened roots restored with the cast post-core (group NMF-RD) demonstrated the lowest fracture resistance values (107.7436 N), which were significantly different from the averages of the remaining groups. The healthy roots restored with the cast post-core (group NMF-RI) showed the highest values (362.3308 N), but statistically significant differences were observed only when compared with weakened roots restored by the dual-cured resin cements (Variolink II, Ivoclar Vivadent - group Vario-RD), chemically cured resin cements (Multilink, Ivoclar Vivadent - group Multi-RD) and resin-modified glass-ionomer cement (Vitremer, 3M ESPE - group Vitre-RD) associated with fiberglass posts. There was not statistically significant differences among the groups of the weakened roots restored with self-adhesive universal resin cement (RelyX Unicem, 3M ESPE - group Unicem-RD), composite resin (Tetric 15 Ceram, Ivoclar Vivadent - group Tetric-RD), group Vitre-RD and group Vario-RD... (Complete abstract click electronic access below)
90

Ação do laser de Er:YAG e de diodo na adesão de elementos sanguíneos e na morfologia de superfícies radiculares irradiadas. Estudo através de microscopia eletrônica de varredura

Theodoro, Letícia Helena [UNESP] 18 June 2003 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:33:28Z (GMT). No. of bitstreams: 0 Previous issue date: 2003-06-18Bitstream added on 2014-06-13T19:04:26Z : No. of bitstreams: 1 theodoro_lh_dr_arafo.pdf: 4192650 bytes, checksum: 68b3ce4f45242d419b74abad0df09354 (MD5) / O objetivo deste estudo foi avaliar in vitro, a adesão de elementos sanguíneos sobre superfícies radiculares irradiadas com laser de Er:YAG e de Diodo, e a ação destes sobre as superfícies radiculares. Foram obtidas 120 amostras de dentes humanos extraídos por doença periodontal, que foram previamente raspados e aplainados com instrumentos manuais, sendo a seguir divididas aleatoriamente em 6 grupos com 20 amostras cada. O G1 (controle)- não recebeu nenhum tratamento; o G2- recebeu aplicação tópica de EDTA 24%; G3- foi irradiado com laser de Er:YAG com 7,6 J/cm2; o G4- irradiado com laser de Er:YAG com 12,9 J/cm 2; o G5 -irradiado com laser de Diodo com 90 J/cm2 e o G6 - foi irradiado com laser de Diodo com 108 J/cm2. Após a realização dos tratamentos, em 10 amostras de cada grupo foi depositado imediatamente a sua punção, tecido sanguíneo originado da vascularização periférica de humano, sendo que 10 amostras não receberam tal tratamento. Após processamento laboratorial as amostras foram analisadas através de microscopia eletrônica de varredura. As fotomicrografias obtidas foram avaliadas através de dois índices: adesão de elementos sanguineos e de morfologia da superfície radicular e estatisticamente analisadas (Kruskall Wallis e Mann-Whitney). Os resultados demonstraram que em relação a adesão de elementos sanguíneos não houve diferenças estatisticamente significante entre o grupo controle e os tratados com o laser de Er:YAG (p=0,7733 e 0,7831) ; O G5 mostrou-se menos efetivo que o controle na adesão de elementos sanguíneos ( p=0,0305 ) e o G2 foi o menos efetivo de todos na adesão. Com relação a morfologia da superfície radicular houve diferenças significantes entre o controle e os grupos do laser de Er:YAG (p= 0,0001) e entre o G5 do Diodo (0,0259); entre o EDTA e os grupos do laser de Er:YAG (p=0,0150 ) e entre o... . / The aim of this study was to evaluate in vitro the adhesion of blood components on root surfaces irradiated with Er:YAG and Diode lasers and these lasers effects on root surfaces. It was obtained 120 samples of human teeth extracted by periodontal disease. They were planed and scaled previously with manual instruments and randomly divided into 06 groups of 20 samples each. The groups were treated according to the following procedures: G1 (Control Group) -received no treatment; G2- had a topical application of EDTA 24%; G3- was irradiated with Er:YAG laser (7,6 J/cmø); G4 - was irradiated with Er:YAG laser (12,9 J/cmø); G5 - was irradiated with Diode laser (90 J/cmø) and G6 was irradiated with Diode laser (108 J/cmø). After these treatments were conducted, 10 samples of each group received a stippler, a blood tissue originated from peripheral vascularization, and the reminiscent samples did not receive such treatment. After laboratorial analysis the samples were analyzed through a scanning electronic microscopy. The photomicrographs obtained were evaluated according to adhesion of blood components and morphology of root surface; and statistically analyzed (Kruskall Wallis and Mann-Whitney). With relation to the adhesion of blood components, the results have shown that there were no significant differences between the Control Group and the groups treated with Er:YAG laser (p=0,7733 and 0,7831); G5 was less effective than the Control Group in adhesion of blood components (p=0,0305) and G2 was the least effective of all groups in this case. With relation to the morphology of root surface there were significant differences among the Control Group, the Er:YAG laser groups (p=0,0001) and the Diode laser G5 (p=0,0259); between the EDTA and the Er:YAG laser groups (p=0,0150) and also between the Diode laser G6 and the Er:YAG laser groups (p=0,0032)... (Complete abstract, click electronic address below).

Page generated in 0.1294 seconds