• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 128
  • 112
  • 29
  • 15
  • 6
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • Tagged with
  • 353
  • 353
  • 117
  • 95
  • 75
  • 47
  • 47
  • 44
  • 42
  • 41
  • 41
  • 38
  • 35
  • 34
  • 32
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
271

Análise dinâmica da ruptura de cabos em torres autoportantes e estaiadas de linhas de transmissão / Dynamic analysis of broken conductor in lattice self-supported and guyed towers of overhead transmission lines

Bentes, Jennefer Lavor January 2013 (has links)
Dentre as possíveis causas na falha da transmissão de energia elétrica, o colapso de torres de linhas de transmissão (LTs) é uma problemática amplamente investigada nas últimas décadas, devido principalmente aos inúmeros acidentes registrados nas LTs em todo o mundo. Neste trabalho, o enfoque é dado à análise dinâmica associada à solicitação proveniente da ruptura de cabos, que quando atuante é capaz de desencadear um fenômeno conhecido como efeito cascata. Para a melhor compreensão da resposta das torres metálicas autoportantes e estaiadas submetidas a esse carregamento dinâmico e buscando contribuir para a determinação de critérios de projeto que visem o estabelecimento adequado de rigidez longitudinal às torres de LTs, foram desenvolvidos modelos numéricos no software ANSYS Mechanical/LS-DYNA, considerando a discretização do modelo estrutural no espaço a partir da utilização do Método de Elementos Finitos e a solução do problema dinâmico ao longo do tempo considerando o método de integração direta implícito das equações de movimento, através do método de Newmark. Inicialmente foram desenvolvidas análises estáticas, conforme considerado nos projetos atualmente. Em seguida, foram desenvolvidos dois tipos de análises dinâmicas: uma simplificada com a aplicação da solicitação através de uma função de carregamento ao longo do tempo, e outra simulada através do desligamento de um elemento finito do condutor. Posteriormente, foram realizadas interpretações e comparações desses resultados. O amortecimento estrutural foi considerado segundo a formulação proposta por Rayleigh e a formação da catenária dos cabos segundo as equações teóricas dadas por Irvine e Caughey. Visando não restringir as respostas a apenas um tipo de trecho simulado, foram desenvolvidos nove modelos numéricos com a variação do tipo de torre analisada, a quantidade de torres por trecho, o nível de amortecimento e o tipo de análise. As respostas dinâmicas são apresentadas em termos da solicitação normal nas barras das estruturas, dos cabos condutores e estais, e dos deslocamentos no topo das torres. / Amidst the main causes of electric energy transmission failure, the collapse of transmission towers is a current research topic in the last decades, due mainly to a huge number of accidents occurring in transmission lines worldwide. In this work, a dynamic analysis was performed associated to the loading due to a broken conductor, which gives rise to a phenomenon known as cascade effect. To better understanding the response of lattice selfsupported and guyed towers under this dynamic load, and in an attempt of determination of criteria for establishment of the longitudinal robustness of transmission line towers, numerical models were developed in the software ANSYS Mechanical/LS-DYNA, considering the discretization of the structural model in space using the finite element method; and the solution of the dynamic problem in the time using the direct integration of the equation of motion, through the Newmark’s method. First, static analyses were performed, accordingly to the considerations of design projects carried out nowadays. Afterwards, two kinds of dynamic analyses were executed: a simplified one, with the applications of the loading using a function in the time and another, which was simulated as a deactivation of a conductor’s finite element. After that, these were submitted to interpretation and comparison among their results. The structural damping was considered in accordance with Rayleigh’s formulation and the catenary of the cables following the equations found by Irvine and Caughey (1974). In order to not restrict the response to one kind of simulation, nine numerical models were developed with the variation of: the kind of tower; the number of towers by line section; the damping level and the type of analysis implemented. The dynamic responses are show in terms of: forces in towers bars; conductors and stays; and the displacements in tower tops.
272

Proteção diferencial digital de linhas de transmissão com compensação série / Digital differential protection of series compensated transmission lines

Eduardo Coelho Navarro 22 August 2002 (has links)
A proteção diferencial é o esquema preferido para proteção de equipamentos e linhas de transmissão. A proteção diferencial exige que informações de todos terminais de zona sob proteção sejam usados para calcular a corrente diferencial. Se esta corrente excede um determinado limite significa que uma falta pode existir na zona protegida. Tais cálculos devem ser executados em cada terminal, consequentemente deve existir um rápido canal de comunicação entre todos os terminais de linha. Este trabalho apresenta o desenvolvimento do algoritmo de uma proteção diferencial digital de linhas de transmissão com compensação em série. O algoritmo proposto foi implementado em Matlab e foi testado com os mais diferentes tipos de faltas simuladas no programa ATP (Alternative Transients Program). Os resultados comprovam o correto funcionamento do algoritmo. O uso de tecnologias atuais de sincronização por GPS (Global Positioning System) e transmissão de dados em banda larga, resolvem antigos problemas da implementação de proteções diferenciais em linhas de transmissão. / The differential protection is the preferred scheme to protect equipment and transmission lines. The differential protection needs information from all terminals of a protected zone to be used to calculate the differential current. If the current exceeds the threshold level, it means that a fault may exist in the protected zone. These computations must be made on each terminal, consequently a fast communication channel connecting all terminals must exist. This work presents the development of a digital differential protection algorithm for series compensated transmission lines. The algorithm was implemented in Matlab and it was tested with the most different variety of faults simulated with ATP (Alternative Transients Program) software. The results proved the correct operation of the algorithm. The use of modern technologies of synchronization such as GPS (Global Positioning System) and data transmission by wide band solved old problems presented by the implementation of differential protection in transmission lines.
273

Detecção e classificação rápida de faltas em linhas de transmissão utilizando redes neurais artificiais / not available

Renan Giovanini 28 August 2000 (has links)
Proteger as linhas de transmissão é uma das tarefas mais importantes dentro dos sistemas elétricos de potência. Faltas em linhas de transmissão devem ser localizadas precisamente e extintas o mais rápido possível. Para tal, o esquema de proteção de linhas utiliza valores amostrados de correntes e tensões para a execução das tarefas de detecção, classificação e localização da falta. Neste esquema, grandezas trifásicas de corrente (IA, IB, IC) e tensão (VA, VB, VC) compõem as entradas do sistema. Após a detecção e classificação da falta, o relé efetua o cálculo da impedância aparente para a verificação da zona de proteção na qual a falta se insere (localização). Dentro deste contexto, a rápida detecção e a correta classificação da falta são passos fundamentais para a lógica de controle de um relé. Para a utilização de sistemas de proteção com alta velocidade de operação, o conjunto detector + classificador deve realizar uma decisão precisa do tipo de falta envolvida em menos de 10 ms após a ocorrência desta. Alguns métodos convencionais têm lidado com este problema, porém os tempos para estimação do tipo de falta são algumas vezes excessivamente longos. Este trabalho apresenta um novo sistema que provê uma rápida e confiável detecção e classificação de faltas através das medidas de valores de correntes trifásicas. O novo método utiliza-se da teoria de Redes Neurais Artificiais, baseada em dois diferentes tipos de redes (MLP e RBF), para a tarefa de detecção e classificação de faltas nos níveis de tempo requeridos para um moderno sistema de proteção. Um estudo comparativo em relação ao desempenho das redes mencionadas também foi realizado. Os testes efetuados para as redes dos tipos MLP e RBF mostraram que o sistema proposto foi capaz de detectar e classificar corretamente 100% dos casos estudados. Deve ainda ser ressaltado, que na maior parte dos casos (93% para a rede MLP e 84% para a rede RBF), o processo de detecção e classificação foi completado com no máximo 5 amostras de pós-falta (5ms). Isto demonstra a rapidez na tarefa de detecção e classificação embutida no método proposto, principalmente levando-se em consideração os tempos apresentados pelos métodos convencionais. / Transmission line protection is one of the major tasks for a power system. Transmission line faults must be located accurately and isolated as fast as possible. In order to perform this task, the power system protection system uses the three-phase currents (IA, IB, IC) and voltages (VA, VB, VC) to detect, classify and locate the fault. After detecting and classifying the fault, the relay calculates the apparent impedance to verify in which protection zone the fault is located. Taking this into account, precise and fast detection and classification methods are fundamental steps for the relay control algorithm. The combination detection + classification must carry out the correct response in less than 10 ms after the fault for a high-speed protection system. Some conventional methods have treated this problem but the time for a correct classification is sometimes excessively long. This work presents a fast and reliable new system for fault detection and classification using the three-phase current measurements. This new system is based on Artificial Neural Networks (RBF and MLP) for the detection and classification tasks. A comparative study involving both types of neural networks was done. Tests showed that the proposed system was able to correctly detect and classify 100% of the studied cases where the majority (93% of the cases for MLP net and 84% for RBF net) of them was done in up to 5 post-fault samples (5 ms). The afore-mentioned demonstrates the high speed of the new method for the detection and classification tasks when compared to the conventional ones.
274

Artificial neural network and Stockwell transform for fault location in transmission lines / Uso de redes neurais artificiais e transformada de Stockwell na localizaÃÃo de faltas em linhas de transmissÃo

Saulo Cunha AraÃjo de Souza 26 June 2015 (has links)
FundaÃÃo Cearense de Apoio ao Desenvolvimento Cientifico e TecnolÃgico / This paper presents an automatic fault location method in transmission lines based on the Travelling Waves Theory (TWT) using the Stockwell Transform (ST) to determine the travelling waves propagation time and the dominant frequency of transient signals generated by faults. The method considers the case where there is no communication between terminals or loss of synchronism between the devices responsible for estimating the location of faults using, therefore, only data from one terminal. Single-phase faults only involving one of the phases and the earth area evaluated, which occur in the first half of a transmission line of unknown parameters. It is observed that the method (i) wasnât sensitive to fault resistance variations and inception angle and (ii) the obtained results presented errors between 0,10% and 5,82% for faults that occurred between 7km and 99km from the monitoring terminal. To improve the accuracy of estimating the fault location, an Artificial Neural Network (ANN) of the type MLP (Multi-Layer Perceptron) is designed, and trained with characteristics extracted from the faulty signals using ST. The ATP (Alternative Transient Program) software was adopted for simulation of a three phase transmission line which voltage signals were sampled at 200kHz. The simulations were performed exploring 1280 combinations of the following parameters: fault locations, fault resistances and inception angle. The method was developed using the software MATLABÂ. According to the obtained results, the combination of ST with ANN presented better results than the application of ST and TWT. Such improvement is highlighted for the estimation of fault location at greater distances from the monitoring terminal, with errors between 0,02% and 1,56% for faults that occurred between 7km and 99km from the monitoring terminal. / Este trabalho apresenta um mÃtodo automÃtico de localizaÃÃo de faltas em linhas de transmissÃo baseado na Teoria das Ondas Viajantes (TOV) utilizando a Transformada de Stockwell (TS) para determinaÃÃo dos tempos de propagaÃÃo das ondas viajantes e da frequÃncia dominante dos sinais transitÃrios gerados pelas situaÃÃes de falta. O mÃtodo considera o caso em que nÃo hà comunicaÃÃo entre terminais ou hà perda de sincronismo entre os equipamentos responsÃveis pela estimaÃÃo da localizaÃÃo das faltas utilizando, portanto, dados provenientes de apenas um terminal. Consideram-se faltas monofÃsicas envolvendo uma das fases e a terra, as quais ocorrem na primeira metade de uma linha de transmissÃo de parÃmetros desconhecidos. Observa-se que o mÃtodo (i) nÃo se mostrou sensÃvel a variaÃÃes de resistÃncia de falta e Ãngulo de incidÃncia e (ii) os resultados obtidos apresentam erros entre 0,10% e 5,82% para faltas que ocorreram entre 7km e 99km do terminal de monitoramento. Para a melhoria da precisÃo na estimaÃÃo da localizaÃÃo das faltas foi projetada uma Rede Neural Artificial (RNA) do tipo MLP (Multi-Layer Perceptron), treinada a partir de caracterÃsticas dos sinais faltosos extraÃdas atravÃs da TS. Foram utilizados os sinais trifÃsicos de tensÃo amostrados na frequÃncia de 200kHz gerados a partir de simulaÃÃes no software ATP (Alternative Transiente Program), no qual foram realizadas 1280 simulaÃÃes explorando diversas localizaÃÃes e resistÃncias de falta e Ãngulo de incidÃncia. O mÃtodo foi aplicado utilizando o software MATLABÂ. De acordo com os resultados obtidos, a combinaÃÃo da TS e RNA projetada apresentou melhores resultados do que a aplicaÃÃo da TS e TOV, destacando-se na estimaÃÃo da localizaÃÃo de faltas que ocorreram a maiores distÃncias do terminal de monitoramento, com erros entre 0,02% e 1,56% para faltas que ocorreram entre 7km e 99km do terminal de monitoramento.
275

Localização de faltas em linhas de transmissão utilizando a teoria de ondas viajantes e transformada Wavelet / Fault Location in Transmission Lines Using Traveling Waves and Wavelet Transform Theory

Murilo da Silva 05 November 2003 (has links)
Este trabalho traz a aplicação da transformada wavelet (TW) para analisar os transitórios de alta freqüência em um sistema de transmissão causados por uma falta sustentada, com o objetivo de se determinar a precisa localização da mesma. A TW, ferramenta matemática empregada neste trabalho, é uma transformação linear muito parecida com a transformada de Fourier, com uma importante diferença: ela permite a localização no tempo de diferentes componentes de freqüência de um dado sinal. Esta localização permite a detecção no tempo da ocorrência de distúrbios abruptos, tais como os transitórios ocasionados por situações de faltas. Os sinais de ondas viajantes geradas pela ocorrência da falta aparecem como distúrbios superpostos aos sinais de freqüência fundamental que são registrados pelos relés. Processando-se estes sinais pelo emprego da TW, esta pode revelar o tempo de propagação dos sinais analisados entre o ponto de ocorrência do distúrbio e a localização física do relé. Conseqüentemente, dispondo-se do intervalo de tempo entre as ondas sobre uma dada linha de transmissão, a distância do ponto de falta pode então ser facilmente determinada, sendo esta a filosofia adotada neste trabalho. O problema delineado é abordado através da implementação prática de um algoritmo computacional. Nesta implementação, o usuário pode escolher a técnica de localização a ser empregada, utilizando-se de dados registrados em um ou em ambos os terminais da linha, conforme a sua necessidade e/ou disponibilidade dos recursos necessários. Com o objetivo de testar e validar a aplicabilidade do algoritmo de localização de faltas, utilizou-se de dados de sinais faltosos obtidos através de simulações do software ATP (Altenative Transients Program), levando-se em conta vários tipos de falta em diferentes localizações ao longo da linha, com diferentes ângulos de incidência, resistências de falta, freqüência de amostragem do sinal, etc. Também foi verificada a influência do acoplamento mútuo em caso de circuitos duplos de transmissão. Os resultados alcançados pelo algoritmo são promissores e demonstram uma ótima precisão e aplicabilidade do método proposto. / This work presents a wavelet transform (WT) application to analyze the high frequency transients in a transmission line caused by a fault, with the purpose of determining its accurate location. The WT is very similar to Fourier Transform (FT), with an important difference: it allows the time determination of different frequency components of a signal. This skill allows the detection of the time of the disturbance occurrence, such as fault transients. The traveling waves generated by the fault occurrence appear as superimposed disturbances on the power frequency signals recorded by the relay. By processing these signals using the WT, the propagation time between the fault point and the relay location can be determined. Consequently, the distance of the fault point can be easily calculated. The delineated problem is boarded through the practical implementation of a computational algorithm. In this implementation, the user can choose the location technique to be employee, using data registered in one or both the terminals of the line, according to the necessity and/or availability of the data. In order to evaluate the applicability of the proposed scheme, the simulation of the transmission line in a faulty condition was utilized. This work makes use of a digital simulator of a faulted EHV (Extra High Voltage) transmission lines known as Alternative Transients Program (ATP). A typical transmission line from CESP (Companhia Energética de São Paulo) were utilized. The simulated data obtained was very close to that found in practice. This study takes into account single phase to ground faults, phase-to-phase faults, phase-phase to ground and three phase faults. The data set was composed of various fault situations considering different fault locations, fault resistances and fault inception angles. The influence of the sampled rate used was also verified as well as the mutual coupling in case of double transmission circuits. The test results reached for the algorithm are promising and demonstrate a highly satisfactory degree of accuracy and applicability of the proposed method.
276

Análise dinâmica da ruptura de cabos em torres autoportantes e estaiadas de linhas de transmissão / Dynamic analysis of broken conductor in lattice self-supported and guyed towers of overhead transmission lines

Bentes, Jennefer Lavor January 2013 (has links)
Dentre as possíveis causas na falha da transmissão de energia elétrica, o colapso de torres de linhas de transmissão (LTs) é uma problemática amplamente investigada nas últimas décadas, devido principalmente aos inúmeros acidentes registrados nas LTs em todo o mundo. Neste trabalho, o enfoque é dado à análise dinâmica associada à solicitação proveniente da ruptura de cabos, que quando atuante é capaz de desencadear um fenômeno conhecido como efeito cascata. Para a melhor compreensão da resposta das torres metálicas autoportantes e estaiadas submetidas a esse carregamento dinâmico e buscando contribuir para a determinação de critérios de projeto que visem o estabelecimento adequado de rigidez longitudinal às torres de LTs, foram desenvolvidos modelos numéricos no software ANSYS Mechanical/LS-DYNA, considerando a discretização do modelo estrutural no espaço a partir da utilização do Método de Elementos Finitos e a solução do problema dinâmico ao longo do tempo considerando o método de integração direta implícito das equações de movimento, através do método de Newmark. Inicialmente foram desenvolvidas análises estáticas, conforme considerado nos projetos atualmente. Em seguida, foram desenvolvidos dois tipos de análises dinâmicas: uma simplificada com a aplicação da solicitação através de uma função de carregamento ao longo do tempo, e outra simulada através do desligamento de um elemento finito do condutor. Posteriormente, foram realizadas interpretações e comparações desses resultados. O amortecimento estrutural foi considerado segundo a formulação proposta por Rayleigh e a formação da catenária dos cabos segundo as equações teóricas dadas por Irvine e Caughey. Visando não restringir as respostas a apenas um tipo de trecho simulado, foram desenvolvidos nove modelos numéricos com a variação do tipo de torre analisada, a quantidade de torres por trecho, o nível de amortecimento e o tipo de análise. As respostas dinâmicas são apresentadas em termos da solicitação normal nas barras das estruturas, dos cabos condutores e estais, e dos deslocamentos no topo das torres. / Amidst the main causes of electric energy transmission failure, the collapse of transmission towers is a current research topic in the last decades, due mainly to a huge number of accidents occurring in transmission lines worldwide. In this work, a dynamic analysis was performed associated to the loading due to a broken conductor, which gives rise to a phenomenon known as cascade effect. To better understanding the response of lattice selfsupported and guyed towers under this dynamic load, and in an attempt of determination of criteria for establishment of the longitudinal robustness of transmission line towers, numerical models were developed in the software ANSYS Mechanical/LS-DYNA, considering the discretization of the structural model in space using the finite element method; and the solution of the dynamic problem in the time using the direct integration of the equation of motion, through the Newmark’s method. First, static analyses were performed, accordingly to the considerations of design projects carried out nowadays. Afterwards, two kinds of dynamic analyses were executed: a simplified one, with the applications of the loading using a function in the time and another, which was simulated as a deactivation of a conductor’s finite element. After that, these were submitted to interpretation and comparison among their results. The structural damping was considered in accordance with Rayleigh’s formulation and the catenary of the cables following the equations found by Irvine and Caughey (1974). In order to not restrict the response to one kind of simulation, nine numerical models were developed with the variation of: the kind of tower; the number of towers by line section; the damping level and the type of analysis implemented. The dynamic responses are show in terms of: forces in towers bars; conductors and stays; and the displacements in tower tops.
277

Espectrometro de ressonancia de spin eletronico para amostras com baixo numero de spins

Sousa, Antonio Carlos Torrezan de 22 August 2005 (has links)
Orientadores: Hugo Enrique Hernandez Figueroa, Gilberto Medeiros Ribeiro / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e da Computação / Made available in DSpace on 2018-08-05T03:16:18Z (GMT). No. of bitstreams: 1 Sousa_AntonioCarlosTorrezande_M.pdf: 2536341 bytes, checksum: 2f6ebfc74e6b1e0305c7887d30758ce9 (MD5) Previous issue date: 2005 / Resumo: O objetivo deste trabalho é construir uma instrumentação que permita a realização de ressonância de spin eletrônico (ESR) em amostras com baixo número de spins, como, por exemplo, pontos quânticos (QDs) auto-formados de InAs. Para isto, este trabalho se propõe em usar cavidades de microfita (MRs). Apesar do seu baixo fator de qualidade, MRs apresentam um alto fator de preenchimento, parâmetro diretamente relacionado com a sensibilidade. Assim, ao analisar como cada dimensão da cavidade influencia na sensibilidade e tendo em mente os outros requisitos da ESR a serem satisfeitos, a geometria final de uma cavidade em GaAs pode ser determinada. Fora a cavidade, todas as transições presentes no sistema foram avaliadas. Por fim, diversos sistemas de detecção foram testados e comprovaram a funcionalidade do sistema montado, completando a análise de todos os elementos de um espectrômetro de ESR / Abstract: The goal of this work is to build an electron-spin resonance (ESR) spectrometer with enhanced sensitivity in order to allow the measurement of samples with a small number of spins such as InAs self-assembled quantum dots (QDs). Here, it is proposed the use of microstrip resonators (MRs) to achieve this goal. Despite of its low quality factor, MRs have a very large filling factor, which boosts the signal-to-noise ratio (SNR) of the system. This way, the final geometry of a MR built on GaAs substrate was determined after fulfilling the requirements from the sensitivity as well as from the ESR. Besides that, all the transitions present in the system were assessed. By the end, some detection systems were tested and proved the working of the system built, completing the analysis of all the elements of a spectrometer / Mestrado / Telecomunicações e Telemática / Mestre em Engenharia Elétrica
278

Planejamento dinâmico da expansão de sistemas de transmissão de energia elétrica

Poubel, Raphael Paulo Braga 27 February 2012 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2016-12-19T12:53:20Z No. of bitstreams: 1 raphaelpaulobragapoubel.pdf: 1692665 bytes, checksum: e8fb69a9681a9af78d618fd006ce0ebd (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2016-12-19T13:07:51Z (GMT) No. of bitstreams: 1 raphaelpaulobragapoubel.pdf: 1692665 bytes, checksum: e8fb69a9681a9af78d618fd006ce0ebd (MD5) / Made available in DSpace on 2016-12-19T13:07:51Z (GMT). No. of bitstreams: 1 raphaelpaulobragapoubel.pdf: 1692665 bytes, checksum: e8fb69a9681a9af78d618fd006ce0ebd (MD5) Previous issue date: 2012-02-27 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Este trabalho apresenta um modelo baseado em métodos heurísticos construtivos para solução do planejamento dinâmico de linhas de transmissão. O acoplamento temporal entre as decisões é representado através de uma modificação nas equações do modelo de fluxo de carga CC onde as perdas nas linhas são incluídas. O problema resultante desta formulação é um problema de otimização inteira com variáveis acopladas no período de planejamento representadas por um parâmetro de expansão. O algoritmo proposto resolve o problema de forma contínua e acoplada para decidir sobre o planejamento de cada ano de forma a evitar a explosão combinatória da programação inteira. Para tanto são utilizadas, para as decisões de expansão, as informações dos coeficientes de Lagrange e do parâmetro de expansão. Testes com o sistema da região Sul e Sudeste do Brasil apontam para uma metodologia eficaz e promissora. / This work presents a model to solve the dynamic planning of transmission lines based on heuristics technique. The temporal coupling among decisions is represented by a modification on the equations of the DC load flow model, in which losses in transmission lines are included. This formulation generates an integer optimization problem with coupled variables in the planning period, represented by an expansion parameter. The proposed algorithm solves the problem in a continuous and coupled way, in order to decide the planning of each year, as well as to avoid combinatorial explosion of the integer technique. Information obtained from the Lagrange multiplier and the expansion parameter are used to take decisions. Tests with Brazilian southern and southeastern systems indicate an effective and promising methodology.
279

Filtro de Kalman Estendido com o modelo da interferência eletromagnetica de linhas de transmissão aplicado a veiculos autônomos aéreos

Silva, Mathaus Ferreira da 28 August 2017 (has links)
Submitted by Geandra Rodrigues (geandrar@gmail.com) on 2017-12-20T12:53:31Z No. of bitstreams: 1 mathausferreiradasilva.pdf: 22275886 bytes, checksum: 2238ed4aba60d835720fda3dd8bc6e46 (MD5) / Rejected by Adriana Oliveira (adriana.oliveira@ufjf.edu.br), reason: Corrigir nome membro da banca e colocar acento no Júnior - do co-orientador Membro da banca: Moraes, Carlos Henrique Valério de on 2017-12-21T11:18:47Z (GMT) / Submitted by Geandra Rodrigues (geandrar@gmail.com) on 2017-12-21T12:02:50Z No. of bitstreams: 1 mathausferreiradasilva.pdf: 22275886 bytes, checksum: 2238ed4aba60d835720fda3dd8bc6e46 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2017-12-22T12:01:34Z (GMT) No. of bitstreams: 1 mathausferreiradasilva.pdf: 22275886 bytes, checksum: 2238ed4aba60d835720fda3dd8bc6e46 (MD5) / Made available in DSpace on 2017-12-22T12:01:34Z (GMT). No. of bitstreams: 1 mathausferreiradasilva.pdf: 22275886 bytes, checksum: 2238ed4aba60d835720fda3dd8bc6e46 (MD5) Previous issue date: 2017-08-28 / Este trabalho tem por objetivo aplicar a técnica do Filtro de Kalman Estendido com ruído colorido a uma aeronave do tipo quadrotor para atenuar a interferência eletro-magnética proveniente de linhas de transmissão de energia de modo a aumentar a confiabilidade e segurança de voos em suas proximidades. Com o intuito de executar missões de monitoramento autônomo, a técnica desenvolvida visa estimar o valor da interferência eletromagnética produzida por linhas de transmissão de energia em alta tensão para que seja possível aplicar a correção necessária. Essa estimação e´ feita a partir do modelo matemático do campo eletromagnético da linha, que leva em consideração a posição, corrente da linha, sistema físico de transmissão, entre outros. Para a avaliação dos resultados, utilizou-se os índices de performance não intrusivos que levam em consideração a integral absoluta do erro (IAE) e a integral do erro quadrático (ISE). Os resultados foram considerados eficientes e aplicáveis com base nos índices de desempenho, permitindo que o quadrotor executasse todas as missões como planejadas, sendo possível ainda a diminuição da distância entre o veículo e a linha de transmissão que, por consequência, permite uma análise mais detalhada e aumenta a qualidade do monitoramento e identificação de avarias ao longo do percurso. / This work aims to apply the Extended Kalman Filter technique with colored noise to a quadrotor-type aircraft to attenuate electromagnetic interference from power trans-mission lines in order to increase the reliability and safety of nearby flights. To perform autonomous monitoring missions, the developed technique aims to estimate the value of the electromagnetic interference produced by high voltage power transmission lines, which makes possible to apply the necessary correction. This estimation is made from the mathematical model of the power line electromagnetic field, which takes into ac-count the position, line current, physical transmission system, among others. In order to evaluate the results, it was used non-intrusive performance indexes that take into account the integrated absolute error (IAE) and the integrated square error (ISE). The results were considered efficient and applicable based on performance indices, allowing the operator to perform all the missions as planned, and the distance between the vehicle and the transmission line can be reduced which, consequently, result in a more detailed analysis and increases the monitoring quality and the faults identification along the route.
280

Microwave oscillator with phase noise reduction using nanoscale technology for wireless systems

Aqeeli, Mohammed Ali M. January 2015 (has links)
This thesis introduces, for the first time, a novel 4-bit, metal-oxide-metal (MOM) digital capacitor switching array (MOMDCSA) which has been implemented into a wideband CMOS voltage controlled oscillator (VCO) for 5 GHz WiMAX/WLAN applications. The proposed MOMDCSA is added both in series and parallel to nMOS varactors. For further gain linearity, a wider tuning range and minor phase noise variations, this varactor bank is connected in parallel to four nMOS varactor pairs, each of which is biased at a different voltage. Thus, VCO tuning gain reduces and optimal phase noise variation is obtained across a wide range of frequencies. Based on this premise, a wideband VCO is achieved with low phase noise variation of less than 4.7 dBc/Hz. The proposed VCO has been designed using UMC 130 nm CMOS technology. It operates from 3.45 GHz to 6.23 GHz, with a phase noise of -133.80 dBc/Hz at a 1 MHz offset, a figure of merit (FoM) of -203.5 dBc/Hz. A novel microstrip low-phase noise oscillator is based on a left-handed (LH) metamaterial bandpass filter which is embedded in the feedback loop of the oscillator. The oscillator is designed at a complex quality factor Qsc peak frequency, to achieve excellent phase noise performance. At a centre frequency of 2.05 GHz, the reported oscillator demonstrates, experimentally, a phase noise of -126.7 dBc/Hz at a 100 kHz frequency offset and a FoM of -207.2 dBc/Hz at a 1 MHz frequency offset. The increasing demands have been placed on the electromagnetic compatibility performance of VCO devices is crucial. Therefore, this thesis extends the potential of highly flexible and conductive graphene laminate to the application of electromagnetic interference (EMI) shielding. Graphene nanoflake-based conductive ink is printed on paper, and then it is compressed to form graphene laminate with a conductivity of 0.43×105 S/m. Shielding effectiveness is experimentally measured at above 32 dB as being between 12GHz and 18GHz, even though the thickness of the graphene laminate is only 7.7µm. This result demonstrates that graphene has great potential for offering lightweight, low-cost, flexible and environmentally friendly shielding materials which can be extended to offering required shielding from electromagnetic interference (EMI), not only for VCO phase noise optimisation, but also for sensitive electronic devices.

Page generated in 0.1056 seconds