• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 588
  • 10
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 1
  • Tagged with
  • 607
  • 297
  • 202
  • 134
  • 84
  • 78
  • 74
  • 73
  • 68
  • 65
  • 63
  • 61
  • 58
  • 57
  • 54
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Máscara laríngea como opção para ventilação com pressão positiva de recém-nascidos em sala de parto.

Tannuri, Abdo Eduardo Garbim January 2018 (has links)
Orientador: João Cesar Lyra / Resumo: Tannuri AEG. Máscara laríngea como opção para ventilação com pressão positiva de recém-nascidos em sala de parto (dissertação). Botucatu: Faculdade de Medicina de Botucatu-UNESP; 2018. Introdução: A ventilação com pressão positiva (VPP) é o procedimento mais importante e efetivo na reanimação neonatal em sala de parto. Quando ocorre falha da ventilação com balão e máscara é necessária a intubação orotraqueal (IOT), que é um procedimento complexo, que exige maior nível de treinamento e experiência do profissional que presta assistência. A máscara laríngea é uma opção de interface que permite o estabelecimento da VPP de forma rápida e efetiva, podendo ser manuseada por profissionais menos experientes. O objetivo deste estudo foi avaliar o tempo para o estabelecimento da VPP eficaz, realizada por profissionais com diferentes níveis de experiência, utilizando três tipos de interface (máscara facial-MF, máscara laríngea-ML e cânula orotraqueal-COT), comparando as interfaces e os profissionais entre si. Métodos: Estudo experimental, com manequim de simulação, com participação de médicos com diferentes níveis de formação em reanimação neonatal, divididos em dois grupos: G1-médicos pediatras em formação (residentes de Pediatria Geral); G2-Neonatologistas e residentes de Neonatologia. Após treinamento, foi proposta situação simulada de reanimação neonatal e os participantes realizaram a ventilação utilizando os 3 dispositivos. As variáveis estudadas foram: falha para estabelecer venti... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Tannuri AEG. Laryngeal mask as an option for positive pressure ventilation of newborns in the delivery room. (dissertação). Botucatu: Faculdade de Medicina de Botucatu-UNESP; 2018. Background: Positive-pressure ventilation (PPV) is the most important and effective procedure in neonatal resuscitation in the delivery room. In case of balloon and mask ventilation faillure orotracheal intubation (IOT) is required. This procedure is complex and requires higher level of training and experience of the caregiver. Laryngeal mask is na interface option that allows the establishment of VPP in a fast and effective way, and can be handled by less experienced professionals. The objective of this study was to evaluate the time to establish effective PPV, performed by professionals with different levels of experience, using three types of interface (FM-face mask, laryngeal mask-LM and orotracheal cannula-OTC). Comparisons where done among interfaces and between professionals. Methods: Experimental study, using simulation manikin, with participation of physicians with diferente levels of training in neonatal resuscitation, divided into two groups: G1-pediatricians in training (residents of General Pediatrics); G2-Neonatologists and residents of Neonatology. After training, a simulated neonatal resuscitation situation was proposed and the participants performed ventilation using the 3 devices. The studied variables were: failure to establish ventilation, time spent for effective ventilation an... (Complete abstract click electronic access below) / Mestre
52

Simulação do escoamento de ar no do auditório da FEUP

Sousa, Ivone Conceição January 2011 (has links)
Tese de mestrado integrado. Engenharia Mecânica. Universidade do Porto. Faculdade de Engenharia. 2011
53

Fachadas ventiladas em edifícios : tipificação de soluções e interpretação do funcionamento conjunto suporte/acabamento

Sousa, Fernando Manuel Fernandes de January 2010 (has links)
Tese de mestrado integrado. Engenharia Civil. Faculdade de Engenharia. Universidade do Porto. 2010
54

Sistemas de ventilação híbridos em edifícios : análise energética resultante da implementação de sistemas de ventilação inovativos

Ferreira, Petra Alexandra de Sousa Vaquero Marado January 2006 (has links)
Tese de mestrado. Engenharia Mecânica. 2006. Faculdade de Engenharia. Universidade do Porto
55

Caracterização do uso específico da energia para ventilação com ênfase nos requisitos de filtragem.

Correia, Ricardo Jorge Teixeira January 2010 (has links)
Estágio realizado na RGA e orientado pelo Engº Luís Graça / Tese de mestrado integrado. Engenharia Mecânica. Faculdade de Engenharia. Universidade do Porto. 2010
56

Desenvolvimento do produto e optimização do processo produtivo : estrutura de suporte de uma torre eólica

Almeida, Paula Mariana Lopes Pinto de January 2008 (has links)
Estágio realizado na Martifer Energy Systems e orientado pelo Eng.º Eduardo Ribeiro / Tese de mestrado integrado. Engenharia Mecânica. Faculdade de Engenharia. Universidade do Porto. 2008
57

A ventilação e o RSECE nas escolas : estudo de impacto energético e estratégias de mitigação

Almeida, Rui Manuel Meira da Cruz January 2008 (has links)
Tese de mestrado integrado. Engenharia Mecânica. Faculdade de Engenharia. Universidade do Porto. 2008
58

Diferentes modalidades ventilatórias durante anestesia prolongada, em coelhos submetidos ao decúbito lateral /

Aidar, Eveline Simões Azenha. January 2017 (has links)
Orientador: Newton Nunes / Coorientação: Ana Paula Gering / Banca: Patrícia Cristina Ferro lopes / Banca; Paula Ferreira da Costa / Resumo: A manutenção da função respiratória adequada é essencial para realização de anestesia segura e eficiente. Sendo assim, são necessários estudos que avaliam métodos ventilatórios e seus empregos na rotina clínica. Neste estudo, foram comparadas a ventilação espontânea (VE), ventilação pressão controlada, ventilação pressão controlada associada à pressão positiva expiratória final e ventilação mandatória intermitente sincronizada (SIMV). As modalidades foram comparadas em quatro grupos de oito animais cada. Os coelhos foram anestesiados com isofluorano durante duas horas e posicionados em decúbito lateral direito, totalizando 32 animais. Variáveis cardiovasculares, ventilatórias e hemogasométricas foram registradas em cinco diferentes momentos, com intervalo de 30 minutos. Após, os resultados foram avaliados estatisticamente pelo método dos quadrados mínimos, seguido pelo teste Tukey - Kramer (p≤0,05). Com relação às variáveis cardiovasculares, as médias de pressão arterial média (PAM) e pressão arterial sistólica (PAS) permaneceram discretamente abaixo dos valores de normalidade em todos os grupos. Houve diminuição significativa da PAM e PAS no grupo ventilação ciclada à pressão associada à pressão positiva no final da expiração (GPP) ao longo do tempo anestésico. Quanto aos gases sanguíneos, a pressão parcial de dióxido de carbono arterial (PaCO2) foi maior no GPP quando comparado aos outros grupos, gerando acidemia respiratória após uma hora de procedimento. As médias altas d... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Maintaining adequate respiratory function is essential for safe and efficient anesthesia. Therefore, studies evaluating ventilatory methods and their use in the clinical routine are necessary. In this study, spontaneous ventilation, pressurecontrolled ventilation, pressure-controlled ventilation associated with positive endexpiratory pressure, and synchronized intermittent mandatory ventilation were compared. The modalities were compared in four groups of eight rabbits each. The rabbits were anesthetized with isofluorane for two hours and placed in the right lateral recumbency, totaling 32 animals. Cardiovascular, ventilatory and hemogasometric variables were recorded at five different moments, with an interval of 30 minutes each. Afterwards, the results were statistically evaluated by the least squares method, followed by the Tukey - Kramer test (p≤0.05). Regarding the cardiovascular variables, mean values of mean arterial pressure (MAP) and systolic blood pressure (SBP) remained slightly below normal values in all groups. There was a significant decrease in MAP and PAS in the group under pressure controlled ventilation associated with positive end-expiratory pressure (GPP) throughout the anesthetic time. As for blood gases, the partial pressure of arterial carbon dioxide was higher in GPP when compared to other groups, generating respiratory acidosis after one hour of procedure. High partial pressure of venous oxygen means suggest a higher supply associated with lower O2 co... (Complete abstract click electronic access below) / Mestre
59

Ventilação natural e desempenho térmico em edifícios verticais multifamiliares em Campo Grande, MS

Versage, Rogério de Souza 24 October 2012 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-graduação em Arquitetura e Urbanismo, Florianópolis, 2009 / Made available in DSpace on 2012-10-24T16:58:11Z (GMT). No. of bitstreams: 1 273865.pdf: 1761626 bytes, checksum: 93aa870529ee09d857f4b040b47804be (MD5) / A crise energética e ambiental exige o consumo racional da energia. No Bra-sil, quase metade da energia elétrica é consumida principalmente no condicionamen-to ambiental das edificações. E no setor residencial, as estratégias de ventilação natural proporcionam grande potencial para obtenção de conforto térmico, contribu-indo na economia de energia ao evitar o uso de condicionamento artificial. Como contribuição ao entendimento deste potencial, este trabalho tem como objetivo avaliar a ventilação natural e desempenho térmico de edifícios verticais multifamili-ares através de simulações com o modelo de rede AirflowNetwork do EnergyPlus, adotando o clima da cidade de Campo Grande, MS. Para o desenvolvimento desta avaliação foram estudados os conceitos sobre coeficientes de descarga, coeficiente de pressão do vento, coeficiente e expoente de fluxo de ar pelas frestas e rugosidade do entorno. Assim como foram estudados os fundamentos dos métodos de cálculo de taxas de ventilação e infiltração de ar em edificações. Para identificar a influência da variação destes parâmetros de ventilação no desempenho térmico foram realiza-das simulações paramétricas em um modelo de edifício referencial respeitando as limitações de obtenção de cada coeficiente, sendo observada a influência da variação dos parâmetros nas taxas de ventilação e graus hora de refrigeração. Após conhecer esta influência foi avaliado o desempenho de um edifício real buscando transpor as restrições de modelagem e determinação de cada coeficiente. O edifício real estuda-do é uma amostra intencional de uma tipologia de edifício multifamiliar comum na cidade de Campo Grande, com quatro apartamentos por andar e planta com formato H. O edifício real foi avaliado por dois métodos diferentes: um padrão, adotando todos os parâmetros default indicados pelo EnergyPlus, e outro avançado, com os parâmetros de ventilação determinados de forma mais detalhada. A avaliação do desempenho térmico do edifício real, seus apartamentos e ambientes foram analisa-dos através de uma escala de graus hora de refrigeração da temperatura do ar exter-no, classificando o seu desempenho entre A e E. Na análise paramétrica do modelo referencial, o coeficiente de descarga foi o parâmetro que mais influenciou no desempenho térmico de graus hora de refrigeração e os coeficientes e expoentes de fluxo de ar pelas fretas e os diferentes métodos de obtenção de coeficientes de pressão de vento apresentaram a menor influência nos resultados de desempenho térmico. Entre a simulação padrão e avançada do edifício real não se pôde concluir qual dos resultados é o mais correto, porém, comparando o comportamento simula-do, as duas simulações apresentaram a mesma tendência de resultados. No resultado da classificação do edifício real, seus apartamentos foram classificados como B e C, resultando em um desempenho médio do edifício completo como B. Contu-do, além das constatações quanto ao desempenho dos edifícios estudados, este traba-lho permitiu verificar o funcionamento da simulação de ventilação natural com o modelo AirflowNetwork do EnergyPlus.
60

Eficácia da ventilação mecânica noturna para resfriamento

Batista, Juliana Oliveira January 2011 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Engenharia Civil. / Made available in DSpace on 2012-10-25T21:05:13Z (GMT). No. of bitstreams: 1 300603.pdf: 6363008 bytes, checksum: 7c7301a3f08aaaaaa9d35ec35fb2bc69 (MD5) / Este trabalho avalia o potencial da ventilação mecânica noturna como estratégia de resfriamento para um ambiente residencial durante o verão, quando associada a configurações construtivas com baixa e média inércia e diferentes padrões de ventilação natural no período diurno. Como objeto de estudo utilizou-se a Casa Eficiente, uma residência experimental localizada em Florianópolis-SC, monitorada entre os meses de dezembro de 2007 a abril de 2008. Simulações computacionais desenvolvidas com o software EnergyPlus v. 6.0 foram calibradas com base nos dados do monitoramento efetuado no quarto de casal, avaliando-se a influência dos algoritmos de condução e convecção nos resultados. Os somatórios de graus-hora de resfriamento calculados para o ambiente em estudo no período de 22/01 a 25/01/2008 (temperatura base = 26?C) apresentaram uma variação de até 78%, dependendo da combinação de algoritmos empregada. Uma vez calibrado, o modelo foi utilizado na análise do desempenho da ventilação mecânica noturna. Os critérios de avaliação foram os somatórios de graus-hora de resfriamento e os percentuais de horas de desconforto, verificados em diferentes horários do dia, sob diferentes padrões de ventilação diurna. Foram quantificados os balanços térmicos internos correspondentes a esses horários, caracterizando-se o comportamento dos componentes da envoltória quanto aos ganhos e perdas de calor. Em função dos diferentes padrões de ventilação simulados, combinados a duas configurações construtivas (inércia baixa e inércia média), foram observadas diferenças de 15% a 290% nos somatórios de graus-hora de resfriamento. Os resultados demonstraram os benefícios do emprego da ventilação mecânica noturna, que reduziu a temperatura do ar, incrementando as perdas de calor pela envoltória durante a madrugada. Observou-se também que a admissão da ventilação durante a tarde diminuiu o efeito de amortecimento das temperaturas internas. Este estudo possibilitou caracterizar a dinâmica do comportamento térmico de um ambiente residencial, quantificando o seu desempenho em diferentes períodos do dia, a fim de indicar alternativas para compatibilizar o uso de estratégias híbridas de ventilação aos padrões de ocupação, de acordo com o nível de inércia térmica. / This work investigates the potential of mechanical night ventilation as a cooling technique for a residential room during summer, when associated to low-inertia and medium-inertia building envelopes, under different daytime ventilation patterns. Field experiments were carried out in the Casa Eficiente, an experimental dwelling located in Florianopólis-SC, from December 2007 to April 2008. EnergyPlus 6.0 simulations were calibrated against field data measured in the master bedroom, analyzing the influence of conduction and convection algorithms in the simulation results. It was observed a variation up to 78% in cooling degree hours of the bedroom (period: 22/01 to 25/01/2008, base temperature = 26 ºC), depending on algorithms combination. After calibration, the model was used for simulations of mechanical night ventilation performance. The cooling degree-hours and the percentage of discomfort hours were established as evaluation criteria, for different times of day, under different daytime ventilation patterns. It were quantified the corresponding heat balances to the bedroom, analyzing heat gains and losses related to each building component. The differences in cooling degree-hours ranged from 15% to 290%, depending on ventilation patterns simulated and envelope features (low-inertia or medium-inertia). The results demonstrated the benefits of mechanical night ventilation use, which reduced air temperature and improved thermal losses by building envelope at early morning. Also, it was observed that daytime ventilation reduced the effect of lowering internal peak temperatures when applied during afternoon. From this study, it was possible characterizing the dynamic of thermal behaviour of a residential room, quantifying its performance at different intervals of the day, leading to recommendations to suit hybrid ventilation strategies to the occupation patterns, according to the room inertia level.

Page generated in 0.0447 seconds