• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 10
  • 8
  • 3
  • 3
  • 1
  • Tagged with
  • 26
  • 26
  • 26
  • 15
  • 10
  • 10
  • 8
  • 7
  • 5
  • 5
  • 4
  • 4
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Effekten av kinesiotejpning på aktivitetsförmåga och smärta hos gravida med pelvic girdle pain – en pilotstudie

Lind, Karin, Trång, Maria January 2010 (has links)
<p><strong> </strong></p><p>Syftet var att undersöka om kinesiotejpning kunde påverka aktivitetsförmåga och smärta hos gravida kvinnor med pelvic girdle pain. Studien var en single subjekt experimentell AB-design. Fyra kvinnor inkluderades i pilotstudien för behandling av pelvic girdle pain. Smärtan skattades och mättes med visuell analog skala. Aktivitetsförmågan mättes med Roland &  Morris disability questionnaire.</p><p>Resultatet visade att gällande aktivitetsförmåga kunde det med 95 % säkerhet ses en förbättring hos tre av kvinnorna. Gällande smärtskattningen kunde endast hos en kvinna på kvällen och hos en annan kvinna på morgonen och kvällen ses en kliniskt signifikant minskad smärta. Resultaten i studien ger underlag för att en mer omfattande randomiserad och kontrollerad klinisk studie bör genomföras.</p>
12

Effekten av kinesiotejpning på aktivitetsförmåga och smärta hos gravida med pelvic girdle pain – en pilotstudie

Lind, Karin, Trång, Maria January 2010 (has links)
Syftet var att undersöka om kinesiotejpning kunde påverka aktivitetsförmåga och smärta hos gravida kvinnor med pelvic girdle pain. Studien var en single subjekt experimentell AB-design. Fyra kvinnor inkluderades i pilotstudien för behandling av pelvic girdle pain. Smärtan skattades och mättes med visuell analog skala. Aktivitetsförmågan mättes med Roland &amp;  Morris disability questionnaire. Resultatet visade att gällande aktivitetsförmåga kunde det med 95 % säkerhet ses en förbättring hos tre av kvinnorna. Gällande smärtskattningen kunde endast hos en kvinna på kvällen och hos en annan kvinna på morgonen och kvällen ses en kliniskt signifikant minskad smärta. Resultaten i studien ger underlag för att en mer omfattande randomiserad och kontrollerad klinisk studie bör genomföras.
13

"Comparação da escala CR10 de Borg com a escala analógica visual (VAS) na avaliação da dor em pacientes com disfunções temporomandibulares". / Comparison of CR10 Borg’s Scale with Visual Analogue Scale (VAS) to assess pain in patients with Temporomandibular Disorders

Adriana do Vale Ferreira Bacci 23 April 2004 (has links)
A Visual Analogue Scale (VAS) e a escala Category-Ratio (CR10) foram aplicadas para mensurar a dor em pacientes com Disfunções Temporomandibulares (DTMs) em dois estudos. No primeiro estudo, em 35 pacientes (Grupo I) foram aplicadas uma versão modificada da escala CR10 em português e a VAS para mensurar a dor espontânea, durante função orofacial e durante palpação antes e após tratamento odontológico. A modificação na CR10 consistiu em um desmembramento das categorias verbais e da escala numérica apresentadas cada uma delas em única coluna em mesma folha. Os coeficientes de correlação de Pearson entre as pontuações da VAS e da CR10 foram 0,85 antes do tratamento odontológico e 0,9 após o tratamento, indicando alta validade de critério. A associação entre os valores numéricos e as categorias verbais da Escala CR10 Modificada mostrou diferenças em relação ao que é proposto na escala original. As categorias: “Moderado”, “Forte” e “Muito Forte” foram associadas a valores superiores aos originais. O segundo estudo foi planejado para investigar se essas discrepâncias nas associações das categorias com os seus valores numéricos eram replicáveis e verificar se não dependiam da forma de apresentação da escala CR10 modificada. Para isso, as escalas foram aplicadas para medir dor em duas novas amostras de pacientes com DTMs antes do tratamento odontológico. A CR10 com nova modificação e a VAS foram aplicadas à primeira amostra (Grupo II , n=23 pacientes). A modificação na CR10 consistiu na apresentação primeiro da escala numérica em uma coluna seguida pela apresentação das categorias verbais em três colunas. A CR10 original e a VAS foram aplicadas à segunda amostra (Grupo III, n=17 pacientes). Os coeficientes de correlação de Pearson foram 0,9 para o Grupo II e 0,8 para o Grupo III, indicando também alta validade de critério. Assim como no primeiro estudo, na escala CR10, as categorias verbais: “Moderado”, “Forte” e “Muito Forte” foram associadas na escala numérica a valores superiores aos propostos na escala original Em ambos estudos, a escala CR10 foi a mais bem avaliada pelos pacientes, segundo a facilidade de compreensão das instruções e a adequação para o registro da dor. Evidencia-se a necessidade de mais estudos para validar a escala CR10 para a língua portuguesa para determinar com precisão a associação das categorias verbais aos valores numéricos. / Visual Analogue Scale (VAS) and Category-Ratio Scale (CR10) were applied to measure pain in patients with Temporomandibular Disorders (TMDs). In the first study, a modified version of CR10 translated to Portuguese and VAS were applied to measure spontaneous pain, functional pain and pain by touch after and before dentistry treatment in 35 patients (Group I). The CR10 modification consisted of presenting the verbal categories and the numerical scale in separated columns in a sheet. Coefficients of Pearson’s correlation between VAS and CR10 scores were .85 and .90 respectively before and after treatment, indicating a high criterion validation. The association of numerical values and verbal categories of Modified CR10 scale were different from the original CR10. The verbal expressions “moderate”, “strong” and “very strong” were attached to higher values. In the second study we investigated if these discrepancies in attaching the verbal categories to the numerical scale were replicable and if they were not an artifact of the way of presenting the modified CR10 scale. To check these topics, the scales were applied to measure pain in two new samples of patients with TMD before dentistry treatment. A new modified version of the CR10 scale and the VAS were applied to the first sample (Group II, n=23 patients). This modification in CR10 scale consisted of presenting first the numerical scale in separate column, and then the verbal categories distributed in three columns. The original CR10 and VAS were applied to the second sample (Group III, n=17 patients). Coefficients of Pearsons correlation between CR10 and VAS were .9 for Group II and .8 for Group III, indicating also high criterion validation. As indicated in the first study, some verbal categories were attached to the numerical scale at higher values than those ones in the original scale. In both studies,, most patients judged the CR10 easier to be understood and more adequate to measure pain than VAS. There is evidence of the necessity of more studies to validate CR10 to Portuguese to determine with precision the association of the verbal categories to the numeric values.
14

Korelace klinických a a elektromyografických nálezů u pacientů se syndromem karpálního tunelu v závislosti na rehabilitační léčbě / Correlations between clinical and electromyographic findings in patients with carpal tunnel syndrome depending on rehabilitation therapy

Koutská, Helena January 2007 (has links)
The aim of this study was to evaluate the therapeutic effect of rehabilitation in patients with carpal tunnel syndrome. The study focused on a comparison between electromyographic findings, the findings of physioterapist-led clinical examinations and the patient's subjective feelings, illustrated by a visual analogue scale of pain intensity. These three types of examinations were carried out prior to the commencement of rehabilitation and following 8 rehabilitation sessions (within a period of 2 months) in a cohort of 15 patients, and correlations between them were described. Given the high prevalence of the disease, an effort was made to find objective examination criteria without the need to resort to electromyography. Powered by TCPDF (www.tcpdf.org)
15

Efeito da eletroestimulação nervosa transcutânea no alívio da dor em nulíparas, na fase ativa do trabalho de parto / Effect of transcutaneous nervous electrical Stimulation for pain relief in nulliparous women in active phase of labor

Santana, Licia Santos 18 November 2011 (has links)
A eletroestimulação nervosa transcutânea (ENT) é um recurso que consiste em administrar impulsos ou estímulos elétricos de frequência variável, assimétricos ou simétricos de correntes bifásicas através de eletrodos superficiais aplicados sobre a região dolorosa. O objetivo deste estudo foi avaliar o efeito da ENT no alívio da dor na fase ativa da dilatação, no trabalho de parto, e constatar o grau de satisfação das parturientes em relação à experiência vivida durante o estudo. Trata-se de um ensaio clínico randomizado e controlado com 46 parturientes, divididas em grupo controle (GC) e grupo de intervenção (GI). Todas as pacientes eram primigestas, com dilatação cervical de 4 cm, em trabalho de parto espontâneo, com contrações regulares para essa fase, sem uso de drogas ocitócicas ao longo do trabalho de parto, de baixo risco gestacional, com membranas ovulares íntegras e feto único. A aplicação da ENT foi feita pela pesquisadora responsável, fixando dois pares de eletrodos nas regiões paravertebrais, um nas raízes nervosas de T10 a L1 e outro par entre S2 e S4. Os parâmetros utilizados na ENT foram: frequência de 100 Hz, largura de pulso de 100 us, intensidade de acordo com a sensibilidade da paciente e duração da aplicação de 30 minutos contínuos. A avaliação da dor foi realizada imediatamente, antes e após a terapêutica, com a escala categórica numérica (ECN), a escala visual analógica (EVA), o diagrama corporal da localização e Questionário McGill na forma reduzida. No puerpério, além dessas avaliações, o grau de satisfação da paciente com relação à intervenção e a presença de um profissional de saúde durante a fase ativa do trabalho de parto foram pesquisados. Os resultados mostraram que houve diferenças estatísticas significantes entre os dois grupos estudados, com relação à intensidade da dor, após a aplicação da ENT, com apenas 34% das pacientes do GI mantendo a classificação da dor como 7 ou mais, em contraste com 83% das pacientes do GC. Por outro lado, não houve diferenças estatísticas em relação à localização da dor, após a aplicação da ENT. As parturientes do GI ficaram mais satisfeitas com a experiência vivida e com o suporte contínuo recebido, durante o período estudado. Os resultados maternos e perinatais foram semelhantes nos dois grupos estudados. Os resultados encontrados demonstram que a aplicação da ENT, no início da fase ativa do trabalho de parto, alivia a dor das parturientes. Além disso, a presença de suporte contínuo exerce efeito positivo sobre as pacientes submetidas a essa intervenção / The transcutaneous electrical nervous stimulation (TENS) is a resource that consists of administering electrical impulses or stimuli of variable frequency, asymmetric or symmetric of two-phase chains to superficial electrodes applied on the painful region. The objective of this study was to evaluate the effect of TENS for pain relief during the active phase of cervix dilation in labor and to assess the degree of maternal satisfaction related to the experience during the study. This is a randomized controlled trial with 46 pregnant women, divided into control group (CG) and intervention group (IG). All patients were primiparous with cervical dilation of 4 cm in spontaneous labor with regular contractions for this phase without the use of oxytocic drugs during labor, lowrisk pregnant women with intact membranes and a single fetus. The application of the TENS was made by the researcher in charge, setting two pairs of electrodes in the paravertebral regions, at the level of the nerve roots from T10 to L1 and another pair between S2 to S4. The parameters used in TENS were: frequency 100 Hz, pulse width 100 us, intensity according to the sensitivity of the patient and duration of application of 30 continuous minutes. Pain assessment was performed immediately before and after therapy with the numerical categorical scale (ECN), the visual analogue scale (VAS), the body chart for pain location and the reduced form of McGill Questionnaire. In the puerperium, in addition to these assessments, the level of patient satisfaction related to the intervention and the presence of a health professional during the active phase of labor has been searched. The results showed statistically significant differences between the two groups regarding the intensity of pain following the implementation of the TENS, with only 34% of IG patients maintaining the score of pain as 7 or more, in contrast to 83% of CG patients. On the other hand, no statistical differences related to the location of the pain after the application of TENS. The mothers of the IG were more satisfied with the experience and the ongoing support received during the study period. The maternal and perinatal outcomes were similar in both groups. The results show that the application of TENS in the early active phase of labor relieves maternal pain. Moreover, the presence of ongoing support has a positive effect on patients undergoing this intervention
16

Correlação da algometria, escala análogo visual, escala numérica de avaliação da dor em mulheres com dor pélvica crônica

Alfonsin, Mariane Meirelles January 2013 (has links)
Introdução: A Dor Pélvica Crônica (DPC) é um problema social, com alta prevalência, acometendo mulheres na idade reprodutiva. Cada vez mais salientamos a importância de investigar instrumentos apropriados para avaliação da dor, facilitando na prática clínica a escolha do melhor método que torne mais completa a avaliação de aspectos da intensidade na mensuração da dor crônica. Portanto, o objetivo deste estudo é correlacionar diferentes instrumentos de avaliação da intensidade dolorosa, a escala numérica (EN), escala visual analógica (EVA) e a algometria de pressão, nas mulheres com DPC, a fim de identificar o instrumento que melhor expressa o quadro doloroso. Métodos: foram avaliadas pelo ginecologista oitenta mulheres encaminhadas ao ambulatório do serviço de Ginecologia e Obstetrícia do Hospital de Clínicas de Porto Alegre (HCPA), trinta e três mulheres apresentaram algum aspecto dos nossos critérios de não inclusão. Selecionamos para participar do estudo quarenta e sete pacientes com DPC, sendo que vinte pacientes apresentavam endometriose diagnosticada por videolaparoscopia e vinte e sete pacientes apresentavam outras causas ginecológicas. Utilizamos no estudo um roteiro para anamnese cujos dados relacionados com a DPC foram coletados, tais como diagnóstico, tratamento, sintomatologia e locais da dor. Escores de dor foram classificados de acordo com a intensidade, através das escalas de dor (EN e EVA), instrumentos baseados no autorrelato do indivíduo e algometria de pressão, para verificar o limiar de dor à pressão das pacientes. Na análise dos dados, a concordância entre as escalas foi avaliada pelo coeficiente de correlação intraclasse (ICC) e a associação entre as escalas com o algômetro foi avaliada pelo coeficiente de correlação de Spearman, o nível de significância adotado foi de 5% (P<0,05). Resultados: As participantes do estudo tinham idade média de 38,3 ± 7,6 anos. Utilizamos o ICC para análise da correlação entre os instrumentos de relato da percepção dolorosa, ou seja, entre as EN e EVA, em relação à dor (0,992), na dismenorreia (1,00) e na dispareunia (0,996), e encontramos excelente concordância entre as escalas, com P<0,01. As associações da algometria com as escalas foram moderadas e inversas, apresentando diferenças estatisticamente significativas, quanto maior a pontuação nas escalas EN e EVA em relação à dispareunia, menores os valores no algômetro, exceto nos pontos LA1 e LA2 em ambos os lados. Também houve associação inversa das escalas EN e EVA na dismenorréia, no ponto LAB2 lado direito e associação inversa no ponto PS lado direito com a escala EVA de dor, com diferenças estatisticamente significativas. Conclusão: As escalas são instrumentos eficientes para avaliação da dor, podendo ser utilizada tanto a EN quanto a EVA na avaliação da intensidade dolorosa. Na avaliação das mulheres com DPC devemos utilizar a algometria de pressão associada à EN ou EVA, instrumentos inversamente proporcionais, confiáveis e sensíveis, tornando menos subjetiva a avaliação da dor para melhor expressar o quadro doloroso. / Introduction: The Chronic Pelvic Pain (CPP) is a social problem, with high prevalence, affecting women in reproductive age. Increasingly, has been emphasised the importance of investigating appropriate instruments for evaluation of pain in clinical practice, by facilitating the choice of the best method to make more complete the evaluation in measuring intensity aspects of chronic pain. Therefore, the objective of this study is to correlate different painful intensity assessment tools, the numeric scale (NS), visual analogue scale (VAS) and algometry pressure, in women with CPP, in order to identify the instrument that best expresses the pain. Methods: were evaluated by the gynecologist eighty women referred to the Gynecology and Obstetrics service, Clinical Hospital of Porto Alegre (HCPA), thirty three women had some aspect of our criteria for not inclusion. The study included forty seven patients, twenty patients had endometriosis diagnosed by laparoscopy and twenty seven patients had other gynecological causes. For the analyses in this study we used a road map for anamnesis whose data related to the CPP was collected, such as diagnosis, treatment, symptoms and pain locations. In addition, pain scores were classified according to intensity, through the pain scales (NS and VAS), based on self-report instruments of individual and algometry, to verify the pressure pain threshold of the patients. Statistically, the agreement between scales was assessed by intraclass correlation coefficient (ICC) and the association between the scales with the algometer were evaluated by Spearman's rank correlation coefficient, the level of significance adopted was 5% (P<0,05). Results: Study participants had an average age of 38.3 ± 7.6 years old. In the statistical analysis, we used ICC reporting instruments of perception painful I mean, between NS and VAS regarding pain (0,992), in dysmenorrhoea (1.00) and Dyspareunia (0.996), and we found excellent correlation between scales, with P<0,01. The associations of algometria with the scales were moderate and inverses, showing differences statistically significant, the higher the score NS and VAS in relation to Dyspareunia smaller values in algometer, except in points LA1 and LA2 on both sides. Indeed, there were also inverse association of scales NS and VAS on dysmenorrhea, in point LAB2 in the right side and inverse association in point PS in the right side with scale VAS of pain, with statistically significant differences. Conclusion: the scales are effective instruments for evaluation of pain, and may be used both in NS and VAS at painful intensity evaluation. In the evaluation of women with CPP should be used the algometry pressure associated with NS or VAS, instruments inversely proportional, reliable and sensitive, making less subjective pain assessment to better express the pain.
17

Towards Effortless Use of Information Technology in Home Healthcare with a Networked Digital Pen

Lind, Leili January 2006 (has links)
When care is moved from the hospital to the home the demands for high quality care still remain. For problems arising from the geographical separation of patients and professional caregivers, information and communication technology may offer important solutions. The overall aim of this thesis was to describe relevant requirements, to design and implement an IT-based system, and finally to evaluate the system’s influence on symptom control and support for both patients/next-of-kin and professional caregivers in advanced home healthcare. Of importance were needs in basic as well as advanced home healthcare, as were usability perspectives of both patients and professional caregivers. Requirement areas such as security, mobility, and responsibility, which should be considered when monitoring patients in the home, were identified. A prototype system for everyday assistance for diabetes patients was designed, and a system for frequent pain assessment for palliative home healthcare patients using a pain diary, digital pen and mobile Internet technology, was developed and evaluated through a qualitative content analysis approach. Twelve palliative cancer patients and six professional caregivers participated. The data collected included an ease-of-use questionnaire, and interviews with patients, spouses and professional caregivers. Patients expressed increased and improved contact with the caregivers, increased participation in their own care, a sense of increased security, and easiness in using the equipment in spite of severe illness and difficulties in comprehending the technology and system intervention. The professional caregivers showed a shifting outlook towards the pain assessment method; an initial cautious outlook due to low expectations of the patients’ abilities to use the pain assessment method and the caregivers’ own reluctance to use the system and change their way-of-working. Despite this, the professional caregivers experienced positive outcomes in terms of an increased awareness of pain, and positive patient influences including increased participation in their care, increased security and improved changes in pain treatment as a response to reported pain assessments. In conclusion, the networked digital pen system provided an effortless method for pain assessment and had positive influences on the care. The results imply that digital pen technology is suitable for the assessment of symptoms by palliative patients since these patients often have a limited capacity to handle technology due to their state of health. / On the day of the public defence date of the doctoral thesis the status of article III and IV was Submitted.
18

Correlação da algometria, escala análogo visual, escala numérica de avaliação da dor em mulheres com dor pélvica crônica

Alfonsin, Mariane Meirelles January 2013 (has links)
Introdução: A Dor Pélvica Crônica (DPC) é um problema social, com alta prevalência, acometendo mulheres na idade reprodutiva. Cada vez mais salientamos a importância de investigar instrumentos apropriados para avaliação da dor, facilitando na prática clínica a escolha do melhor método que torne mais completa a avaliação de aspectos da intensidade na mensuração da dor crônica. Portanto, o objetivo deste estudo é correlacionar diferentes instrumentos de avaliação da intensidade dolorosa, a escala numérica (EN), escala visual analógica (EVA) e a algometria de pressão, nas mulheres com DPC, a fim de identificar o instrumento que melhor expressa o quadro doloroso. Métodos: foram avaliadas pelo ginecologista oitenta mulheres encaminhadas ao ambulatório do serviço de Ginecologia e Obstetrícia do Hospital de Clínicas de Porto Alegre (HCPA), trinta e três mulheres apresentaram algum aspecto dos nossos critérios de não inclusão. Selecionamos para participar do estudo quarenta e sete pacientes com DPC, sendo que vinte pacientes apresentavam endometriose diagnosticada por videolaparoscopia e vinte e sete pacientes apresentavam outras causas ginecológicas. Utilizamos no estudo um roteiro para anamnese cujos dados relacionados com a DPC foram coletados, tais como diagnóstico, tratamento, sintomatologia e locais da dor. Escores de dor foram classificados de acordo com a intensidade, através das escalas de dor (EN e EVA), instrumentos baseados no autorrelato do indivíduo e algometria de pressão, para verificar o limiar de dor à pressão das pacientes. Na análise dos dados, a concordância entre as escalas foi avaliada pelo coeficiente de correlação intraclasse (ICC) e a associação entre as escalas com o algômetro foi avaliada pelo coeficiente de correlação de Spearman, o nível de significância adotado foi de 5% (P<0,05). Resultados: As participantes do estudo tinham idade média de 38,3 ± 7,6 anos. Utilizamos o ICC para análise da correlação entre os instrumentos de relato da percepção dolorosa, ou seja, entre as EN e EVA, em relação à dor (0,992), na dismenorreia (1,00) e na dispareunia (0,996), e encontramos excelente concordância entre as escalas, com P<0,01. As associações da algometria com as escalas foram moderadas e inversas, apresentando diferenças estatisticamente significativas, quanto maior a pontuação nas escalas EN e EVA em relação à dispareunia, menores os valores no algômetro, exceto nos pontos LA1 e LA2 em ambos os lados. Também houve associação inversa das escalas EN e EVA na dismenorréia, no ponto LAB2 lado direito e associação inversa no ponto PS lado direito com a escala EVA de dor, com diferenças estatisticamente significativas. Conclusão: As escalas são instrumentos eficientes para avaliação da dor, podendo ser utilizada tanto a EN quanto a EVA na avaliação da intensidade dolorosa. Na avaliação das mulheres com DPC devemos utilizar a algometria de pressão associada à EN ou EVA, instrumentos inversamente proporcionais, confiáveis e sensíveis, tornando menos subjetiva a avaliação da dor para melhor expressar o quadro doloroso. / Introduction: The Chronic Pelvic Pain (CPP) is a social problem, with high prevalence, affecting women in reproductive age. Increasingly, has been emphasised the importance of investigating appropriate instruments for evaluation of pain in clinical practice, by facilitating the choice of the best method to make more complete the evaluation in measuring intensity aspects of chronic pain. Therefore, the objective of this study is to correlate different painful intensity assessment tools, the numeric scale (NS), visual analogue scale (VAS) and algometry pressure, in women with CPP, in order to identify the instrument that best expresses the pain. Methods: were evaluated by the gynecologist eighty women referred to the Gynecology and Obstetrics service, Clinical Hospital of Porto Alegre (HCPA), thirty three women had some aspect of our criteria for not inclusion. The study included forty seven patients, twenty patients had endometriosis diagnosed by laparoscopy and twenty seven patients had other gynecological causes. For the analyses in this study we used a road map for anamnesis whose data related to the CPP was collected, such as diagnosis, treatment, symptoms and pain locations. In addition, pain scores were classified according to intensity, through the pain scales (NS and VAS), based on self-report instruments of individual and algometry, to verify the pressure pain threshold of the patients. Statistically, the agreement between scales was assessed by intraclass correlation coefficient (ICC) and the association between the scales with the algometer were evaluated by Spearman's rank correlation coefficient, the level of significance adopted was 5% (P<0,05). Results: Study participants had an average age of 38.3 ± 7.6 years old. In the statistical analysis, we used ICC reporting instruments of perception painful I mean, between NS and VAS regarding pain (0,992), in dysmenorrhoea (1.00) and Dyspareunia (0.996), and we found excellent correlation between scales, with P<0,01. The associations of algometria with the scales were moderate and inverses, showing differences statistically significant, the higher the score NS and VAS in relation to Dyspareunia smaller values in algometer, except in points LA1 and LA2 on both sides. Indeed, there were also inverse association of scales NS and VAS on dysmenorrhea, in point LAB2 in the right side and inverse association in point PS in the right side with scale VAS of pain, with statistically significant differences. Conclusion: the scales are effective instruments for evaluation of pain, and may be used both in NS and VAS at painful intensity evaluation. In the evaluation of women with CPP should be used the algometry pressure associated with NS or VAS, instruments inversely proportional, reliable and sensitive, making less subjective pain assessment to better express the pain.
19

Efeito neuromuscular das técnicas fisioterapeuticas bandagem funcional e corrente interferencial na síndrome tensional cervical / Neuromuscular effect of spair tape and interferencial current as a physiotherapic intervention on cervical tension

Moura, Melissa Luiza 16 August 2018 (has links)
Orientador: Antonio Carlos de Moraes / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Educação Física / Made available in DSpace on 2018-08-16T13:36:04Z (GMT). No. of bitstreams: 1 Moura_MelissaLuiza_M.pdf: 5391341 bytes, checksum: 1aaa11b5c3366a4040a0fe7a901723f9 (MD5) Previous issue date: 2010 / Resumo: A síndrome tensional cervical (STC) é a tensão no músculo trapézio decorrente de atividades repetitivas e aumento da carga muscular estática associados à postura inadequada da cintura escapular. O objetivo deste estudo foi comparar a eficácia da bandagem funcional (BF) e da corrente interferencial (CI) no alívio da dor da STC através da escala visual analógica da dor (EVA) e, confrontar as respostas dos sinais eletromiográficos do músculo trapézio descendente antes e após cada intervenção. 30 voluntárias do sexo feminino, com hipótese diagnóstica de STC foram avaliadas, com média de idade, estatura e massa corpórea de 28,2 anos, 1,61 m e 59,2 kg, respectivamente. Foram divididas em três grupos, com 10 indivíduos cada: Grupo Bandagem Funcional (GBF) - intervenção de 24 horas com bandagem funcional no músculo trapézio superior; Grupo Corrente Interferencial (GCI) - três dias consecutivos (GCI dia 1, 2 e 3) com intervenção de eletroterapia de 30 minutos cada dia; Grupo Controle (GC) - 30 minutos em repouso. Antes e após as intervenções foram mensuradas as respostas subjetivas da dor através da EVA e, as respostas da atividade elétrica da musculatura. Utilizou-se estatística descritiva para caracterização da amostra, apresentando valores referentes às variáveis selecionadas no estudo. Para os valores expressos em RMS e FM foi utilizado o teste de normalidade Shapiro-Wilk. Utilizou-se a análise de variância (ANOVA) one way, para análise entre os tratamentos no momento após. O teste t foi utilizado para análise intragrupos, comparando antes e após de cada grupo, e antes do GCI dia 1 com o após do GCI dia 3. Para a análise da EVA foi utilizado o teste de normalidade Shapiro-Wilk. Para a comparação das variações da EVA (antes e após as intervenções) utilizou-se o teste não paramétrico de Mann Whitney e quando normal, teste t. O nível de significância adotado foi de 5%. Os valores subjetivos da dor indicados pelas voluntárias através da EVA antes de iniciar o teste, com ou sem intervenção, foram maiores do que após o mesmo, indicando um quadro álgico doloroso. A variação percentual entre antes e após a intervenção da dor foi significativamente maior em GBF (70,75%) e GCI dia 3 (81,45%), em relação ao GC (5,83%) (p<0,05), representando diminuição significativa da dor com a intervenção. Já quanto à variação eletromiográfica em RMS e em FM não apresentou diferença estatisticamente significativa em nenhuma intervenção. Os resultados demonstram que a utilização de intervenções como BF e/ou CI em procedimentos fisioterapêuticos são alternativas igualmente eficazes para diminuição da percepção subjetiva da dor. Já através da EMG há aumento no recrutamento muscular para exercer contração isométrica voluntária máxima após intervenção de ambos os recursos avaliados. / Abstract: Cervical tension syndrome (CTS) is the tension in the trapezius muscle due to repetitive activities and increased static muscle load associated with bad posture of the shoulder girdle. The aim of this study was to compare the effectiveness of taping (BF) and interferential current (IC) in relieving the pain of CTS by the visual analogue scale (VAS), and compare the electromyographic responses (EMG) of the upper trapezius muscle before and after each intervention. 30 female volunteers with the diagnosis of CTS were evaluated, mean age, height and body mass index of 28.2 years, 1.61 m and 59.2 kg, respectively. Were divided into three groups, with 10 subjects each: Group Taping (GBF) - 24-hours of taping intervention on upper trapezius muscle, Group Interferential Current (GCI) - three consecutive days (GCI days 1, 2 and 3) with 30 minutes each day of electrotherapy intervention; Control Group (GC) - 30 minutes lying. Before and after the interventions were measured the subjective responses of pain by VAS, and the responses of the electrical activity of muscles. We used descriptive statistics to characterize the sample, with values on the variables selected in this study. The values expressed in EMG was used the normality test Shapiro-Wilk. We used analysis of variance (ANOVA) one way for analysis between treatments at the time after it. The t test was used for intragroup analysis, comparing before and after each group, and before the first day with the GCI with the GCI after the third day. For the analysis of VAS was used the normality test Shapiro-Wilk. For comparison of changes in VAS (before and after the interventions) used the Mann Whitney non parametric test and when normal, t test. The level of significance was 5%. Subjective values of pain indicated by the volunteers through the VAS before starting the test, with or without intervention, were higher than after the same, indicating painful. The percentage change between before and after the intervention of pain was significantly higher in the GBF (70.75%) and GCI day 3 (81.45%) compared to CG (5.83%) (p <0.05), representing a significant decrease in pain with the intervention. For the EMG variation in RMS and FM the statistics were not significant in any intervention. The results demonstrate that the use of interventions such as BF and/or IC in physical therapy procedures are equals effective alternative to reduce the subjective perception of pain. Already there is an increase over the EMG of muscle recruitment to exert maximal voluntary isometric contraction. / Mestrado / Ciencia do Desporto / Mestre em Educação Física
20

Efeito da eletroestimulação nervosa transcutânea no alívio da dor em nulíparas, na fase ativa do trabalho de parto / Effect of transcutaneous nervous electrical Stimulation for pain relief in nulliparous women in active phase of labor

Licia Santos Santana 18 November 2011 (has links)
A eletroestimulação nervosa transcutânea (ENT) é um recurso que consiste em administrar impulsos ou estímulos elétricos de frequência variável, assimétricos ou simétricos de correntes bifásicas através de eletrodos superficiais aplicados sobre a região dolorosa. O objetivo deste estudo foi avaliar o efeito da ENT no alívio da dor na fase ativa da dilatação, no trabalho de parto, e constatar o grau de satisfação das parturientes em relação à experiência vivida durante o estudo. Trata-se de um ensaio clínico randomizado e controlado com 46 parturientes, divididas em grupo controle (GC) e grupo de intervenção (GI). Todas as pacientes eram primigestas, com dilatação cervical de 4 cm, em trabalho de parto espontâneo, com contrações regulares para essa fase, sem uso de drogas ocitócicas ao longo do trabalho de parto, de baixo risco gestacional, com membranas ovulares íntegras e feto único. A aplicação da ENT foi feita pela pesquisadora responsável, fixando dois pares de eletrodos nas regiões paravertebrais, um nas raízes nervosas de T10 a L1 e outro par entre S2 e S4. Os parâmetros utilizados na ENT foram: frequência de 100 Hz, largura de pulso de 100 us, intensidade de acordo com a sensibilidade da paciente e duração da aplicação de 30 minutos contínuos. A avaliação da dor foi realizada imediatamente, antes e após a terapêutica, com a escala categórica numérica (ECN), a escala visual analógica (EVA), o diagrama corporal da localização e Questionário McGill na forma reduzida. No puerpério, além dessas avaliações, o grau de satisfação da paciente com relação à intervenção e a presença de um profissional de saúde durante a fase ativa do trabalho de parto foram pesquisados. Os resultados mostraram que houve diferenças estatísticas significantes entre os dois grupos estudados, com relação à intensidade da dor, após a aplicação da ENT, com apenas 34% das pacientes do GI mantendo a classificação da dor como 7 ou mais, em contraste com 83% das pacientes do GC. Por outro lado, não houve diferenças estatísticas em relação à localização da dor, após a aplicação da ENT. As parturientes do GI ficaram mais satisfeitas com a experiência vivida e com o suporte contínuo recebido, durante o período estudado. Os resultados maternos e perinatais foram semelhantes nos dois grupos estudados. Os resultados encontrados demonstram que a aplicação da ENT, no início da fase ativa do trabalho de parto, alivia a dor das parturientes. Além disso, a presença de suporte contínuo exerce efeito positivo sobre as pacientes submetidas a essa intervenção / The transcutaneous electrical nervous stimulation (TENS) is a resource that consists of administering electrical impulses or stimuli of variable frequency, asymmetric or symmetric of two-phase chains to superficial electrodes applied on the painful region. The objective of this study was to evaluate the effect of TENS for pain relief during the active phase of cervix dilation in labor and to assess the degree of maternal satisfaction related to the experience during the study. This is a randomized controlled trial with 46 pregnant women, divided into control group (CG) and intervention group (IG). All patients were primiparous with cervical dilation of 4 cm in spontaneous labor with regular contractions for this phase without the use of oxytocic drugs during labor, lowrisk pregnant women with intact membranes and a single fetus. The application of the TENS was made by the researcher in charge, setting two pairs of electrodes in the paravertebral regions, at the level of the nerve roots from T10 to L1 and another pair between S2 to S4. The parameters used in TENS were: frequency 100 Hz, pulse width 100 us, intensity according to the sensitivity of the patient and duration of application of 30 continuous minutes. Pain assessment was performed immediately before and after therapy with the numerical categorical scale (ECN), the visual analogue scale (VAS), the body chart for pain location and the reduced form of McGill Questionnaire. In the puerperium, in addition to these assessments, the level of patient satisfaction related to the intervention and the presence of a health professional during the active phase of labor has been searched. The results showed statistically significant differences between the two groups regarding the intensity of pain following the implementation of the TENS, with only 34% of IG patients maintaining the score of pain as 7 or more, in contrast to 83% of CG patients. On the other hand, no statistical differences related to the location of the pain after the application of TENS. The mothers of the IG were more satisfied with the experience and the ongoing support received during the study period. The maternal and perinatal outcomes were similar in both groups. The results show that the application of TENS in the early active phase of labor relieves maternal pain. Moreover, the presence of ongoing support has a positive effect on patients undergoing this intervention

Page generated in 0.0639 seconds