• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 10
  • 3
  • Tagged with
  • 16
  • 6
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Aplicações analíticas do eletrodo híbrido modificado acetato de celulose/grafite/azul da prússia

Nectoux, Aline da Silveira January 2015 (has links)
Neste trabalho foram estudadas as potencialidades eletroanalíticas de um material híbrido condutor baseado em acetato de celulose e grafite com eletrodeposição de filme condutor de Azul da Prússia (CA/G/PB) como sensor para espécies com importância biológica. O material híbrido foi preparado pelo processo de inversão de fase e caracterizado pelas técnicas de microscopia eletrônica de varredura acoplada com espectroscopia de energia dispersiva (SEM-EDS) e voltametria cíclica. O composto Azul da Prússia (PB) foi imobilizado na superfície do material por eletropolimerização, aplicando-se um potencial fixo de 20 mV em uma janela de -0,3 V a 1,2 V. Os estudos eletroquímicos do eletrodo modificado CA/G/PB foram realizados em solução de KCl 0,1 mol.L-1, sendo obtidos dois pares redox para a espécie eletroativa imobilizada com potenciais médios (E0) em 0,204 V e 0,842 V, indicando um comportamento quase-reversível. O eletrodo demonstrou alta estabilidade após 500 ciclos redox, não sendo observada lixiviação da espécie eletroativa da superfície da matriz modificada. Os dois pares redox do material híbrido CA/G/PB permaneceram praticamente constantes entre os pH 5,0 e 8,0, indicando que as intensidades de pico não são significativamente afetadas nessa faixa de pH. A correlação linear entre as intensidades de pico e a raiz quadrada da velocidade de varredura, indicou que o sistema possui um comportamento similar aqueles em que o processo é controlado por difusão das espécies eletroativas à superfície do eletrodo. O azul da Prússia imobilizado foi aplicado na determinação de dopamina (DP), ácido úrico (AU), ácido ascórbico (AA) e Paracetamol (PCT) através da técnica de voltametria cíclica, voltametria de pulso diferencial e cronoamperometria. / In this work, we studied the electroanalytical potential of a conductive hybrid material based on cellulose acetate and graphite with electrodeposition Blue conductor film of Prussia (CA / G / PB) as a sensor for species with biological importance. The hybrid material was prepared by phase inversion process and characterized by the techniques of scanning electron microscopy coupled with energy dispersive spectroscopy (SEM-EDS) and cyclic voltammetry. The dye of Prussian blue (PB) was immobilized on the surface of the material by electropolymerization applying a fixed potential of 20 mV in a interval from -0.3 V to 1.2 V. The electrochemical behavior of the modified electrode CA / G / PB were performed in solution of 0.1 mol L-1 KCl being obtained two redox couples for the electroactive species immobilized with midpoint potentials (E0) in 0.204 V and 0.842 V, indicating a quasi-reversible behavior. The electrode showed high stability after 500 redox cycles with no observed leaching of electroactive species to the surface of the modified electrode. The two redox pair of the CA / G / PB electrode was kept practically constant within pH 5.0 and 8.0, indicating that the peak intensities are not significantly affected in this pH range. The linear correlation between peak intensities and the square root of scan rate, indicated that the system has a similar behavior those in which the process is controlled by diffusion of electroactive species to the electrode surface. The immobilized Prussian blue was applied to determine dopamine (DP), uric acid (UA), ascorbic acid (AA) and paracetamol (PCT) by analytical techniques of cyclic voltammetry, differential pulse voltammetry and chronoamperometry.
12

Aplicações analíticas do eletrodo híbrido modificado acetato de celulose/grafite/azul da prússia

Nectoux, Aline da Silveira January 2015 (has links)
Neste trabalho foram estudadas as potencialidades eletroanalíticas de um material híbrido condutor baseado em acetato de celulose e grafite com eletrodeposição de filme condutor de Azul da Prússia (CA/G/PB) como sensor para espécies com importância biológica. O material híbrido foi preparado pelo processo de inversão de fase e caracterizado pelas técnicas de microscopia eletrônica de varredura acoplada com espectroscopia de energia dispersiva (SEM-EDS) e voltametria cíclica. O composto Azul da Prússia (PB) foi imobilizado na superfície do material por eletropolimerização, aplicando-se um potencial fixo de 20 mV em uma janela de -0,3 V a 1,2 V. Os estudos eletroquímicos do eletrodo modificado CA/G/PB foram realizados em solução de KCl 0,1 mol.L-1, sendo obtidos dois pares redox para a espécie eletroativa imobilizada com potenciais médios (E0) em 0,204 V e 0,842 V, indicando um comportamento quase-reversível. O eletrodo demonstrou alta estabilidade após 500 ciclos redox, não sendo observada lixiviação da espécie eletroativa da superfície da matriz modificada. Os dois pares redox do material híbrido CA/G/PB permaneceram praticamente constantes entre os pH 5,0 e 8,0, indicando que as intensidades de pico não são significativamente afetadas nessa faixa de pH. A correlação linear entre as intensidades de pico e a raiz quadrada da velocidade de varredura, indicou que o sistema possui um comportamento similar aqueles em que o processo é controlado por difusão das espécies eletroativas à superfície do eletrodo. O azul da Prússia imobilizado foi aplicado na determinação de dopamina (DP), ácido úrico (AU), ácido ascórbico (AA) e Paracetamol (PCT) através da técnica de voltametria cíclica, voltametria de pulso diferencial e cronoamperometria. / In this work, we studied the electroanalytical potential of a conductive hybrid material based on cellulose acetate and graphite with electrodeposition Blue conductor film of Prussia (CA / G / PB) as a sensor for species with biological importance. The hybrid material was prepared by phase inversion process and characterized by the techniques of scanning electron microscopy coupled with energy dispersive spectroscopy (SEM-EDS) and cyclic voltammetry. The dye of Prussian blue (PB) was immobilized on the surface of the material by electropolymerization applying a fixed potential of 20 mV in a interval from -0.3 V to 1.2 V. The electrochemical behavior of the modified electrode CA / G / PB were performed in solution of 0.1 mol L-1 KCl being obtained two redox couples for the electroactive species immobilized with midpoint potentials (E0) in 0.204 V and 0.842 V, indicating a quasi-reversible behavior. The electrode showed high stability after 500 redox cycles with no observed leaching of electroactive species to the surface of the modified electrode. The two redox pair of the CA / G / PB electrode was kept practically constant within pH 5.0 and 8.0, indicating that the peak intensities are not significantly affected in this pH range. The linear correlation between peak intensities and the square root of scan rate, indicated that the system has a similar behavior those in which the process is controlled by diffusion of electroactive species to the electrode surface. The immobilized Prussian blue was applied to determine dopamine (DP), uric acid (UA), ascorbic acid (AA) and paracetamol (PCT) by analytical techniques of cyclic voltammetry, differential pulse voltammetry and chronoamperometry.
13

Desenvolvimento de métodos eletroquímicos para determinação de neurotransmissores utilizando eletrodos de zircônia nanoestruturada e diamante dopado com boro / Development of methods for determination of gas electrodemical neurotransmitters using electrodes nanostrctured zirconia and boron-doped diamond

Paranhos, Maysa de Melo 28 January 2014 (has links)
Submitted by Luciana Ferreira (lucgeral@gmail.com) on 2015-01-27T13:24:18Z No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Dissertação - Maysa de Melo Paranhos - 2014.pdf: 2355457 bytes, checksum: 7b3e122ce6fe59cb047d8e835e921f53 (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2015-01-28T11:04:11Z (GMT) No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Dissertação - Maysa de Melo Paranhos - 2014.pdf: 2355457 bytes, checksum: 7b3e122ce6fe59cb047d8e835e921f53 (MD5) / Made available in DSpace on 2015-01-28T11:04:11Z (GMT). No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Dissertação - Maysa de Melo Paranhos - 2014.pdf: 2355457 bytes, checksum: 7b3e122ce6fe59cb047d8e835e921f53 (MD5) Previous issue date: 2014-01-28 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / Fundação de Amparo à Pesquisa do Estado de Goiás - FAPEG / DSA® electrodes modified with films ErYZrO2 or YZrO2 and boron-doped diamond electrodes (BDD) were tested as electrochemical sensors detect front of the neurotransmitter epinephrine and its interfering ascorbic acid (AA) and uric acid (UA), which coexist with epinephrine in biological fluids and are also electroactive, rusting in the same potential that epinephrine. The physical and morphological characterization of the films of ZrO2 were performed using the techniques of XRD, SEM / FEG, EDXS and Open circuit potential. For electrochemical characterization of the sensor in developing were used the techniques of cyclic voltammetry (CV), differential pulse voltammetry (DPV) and Flow Injection Analysis with Amperometric Detection. The analyzes used for physical and morphological characterization of the ZrO2 films demonstrated that the technique of spin coating together with the methodology used for the deposition of ZrO2 films on the surface of substrate DSA® showed films were obtained satisfactory. The BDD electrodes showed good catalytic activity for both analyzed substances (EP, AA and UA). While BDD electrode showed good sensitivity for detection of EP in the presence of AA, electrodes ZrO2 addition to good sensitivity and selectivity showed good reproducibility for the detection of EP without interference from UA and AA. / Eletrodos a base de DSA® modificados com filmes de ErYZrO2 e YZrO2 bem como eletrodos de Diamante Dopado com Boro (DDB) foram testados como sensores eletroquímicos para a detecção eletroquímica do neurotransmissor Epinefrina (EP) e de seus interferentes ácido ascórbico (AA) e ácido úrico (AU), os quais coexistem com a EP nos fluidos biológicos oxidando-se praticamente no mesmo potencial. As caracterizações física, química e morfológica dos filmes a base de ZrO2 foram realizadas por meio das técnicas de DRX, MEV/FEG, EDXS e potencial de circuito aberto. Para caracterização eletroquímica do sensor produzido foram utilizadas as técnicas de Voltametria Cíclica (VC), Voltametria de Pulso Diferencial (VPD) e Análise por Injeção em Fluxo em modo Amperométrico. As análises utilizadas para caracterização física e morfológica dos filmes a base de ZrO2 mostraram que a técnica de spin-coating juntamente com a metodologia utilizada para deposição dos filmes a base de ZrO2 sobre substrato de DSA® permitiu a obtenção dos filmes espessos e com boa homogeneidade. O eletrodo de DDB apresentou boa atividade eletroquímica para as substâncias analisadas (EP, AA e AU). Enquanto eletrodos de DDB apresentaram boa sensibilidade para detecção de EP na presença de AA, eletrodos de ZrO2, além de boa sensibilidade, apresentaram seletividade e boa reprodutibilidade para detecção de EP sem interferência de AU e AA.
14

Aplicação de métodos voltamétricos de análise na especiação de cromo, selênio e antimônio em matrizes salinas / Application of voltammetric methods to the speciation analysis of chromium, selenium and antimony in saline matrices

Jost, Cristiane Luisa 04 February 2010 (has links)
Conselho Nacional de Desenvolvimento Científico e Tecnológico / This work aimed to explore the speciation analysis of chromium, selenium and antimony, elements of clinical and geochemical relevance, in the saline samples seawater, hydrothermal fluid and hemodialysis fluid. These samples, although linked to different research areas, have many similarities relating to their chemical compositions or the presence of metallic species as contaminants as well as major components. Voltammetric methods were used to the determination of the analytes in high salt media without the use of dilution, masking agents or separation steps. Since changes in the matrix composition may affect the analyte peak current magnitude, factors affecting the voltammetric behavior of the species related to sample composition (e.g., presence of dissolved organic matter and ionic strength) were evaluated. The chromium speciation analysis was performed by the adsorptive collection of the Cr-DTPA complex on the mercury working electrode, followed by stripping in combination to a catalytic step. Cr(III) species was found as predominant in the hydrothermal fluid sample and, Cr(VI), in the seawater sample, whereas in hemodialysis fluids an ignorable concentration was determined. Selenium was determined by the co-electrolysis of Cu2Se followed by a cathodic stripping in acidic medium. The UV-irradiation pre-treatment step was used for the reductively conversion of non-electroactive species into Se(IV) as well as for dissolved organic matter photo-oxidation, and the speciation was applied to the real sample analysis, where no selenium species were found. The combined use of adsorptive and anodic stripping voltammetry was employed for antimony determination. Chloranilic acid was chosen as the Sb(III) complex forming reagent (pH 3.0) and the total antimony concentration was evaluated by anodic stripping voltammetry in a 5.0 mol L-1 HCl medium. Sb(III) was found as the predominant species in the hydrothermal fluid sample, whereas Sb(V) is predominant in the seawater sample. No antimony species were found in the hemodialysis fluid. Concerning chromium, selenium and antimony species, remarkable peak current dependences on peak potential, deposition potential, deposition time and scan rate were observed for all investigated media. The limit of detection values were appropriate to the analytes determination, so that the present techniques consist in simple, fast and low cost procedures for the speciation analysis of elements of clinical and geochemical relevance in high salt content samples with accuracy and sensitivity. / Este trabalho teve como objetivo explorar a análise de especiação de cromo, selênio e antimônio, elementos de relevância clínica e geoquímica, em amostras salinas água do mar, fluido hidrotermal e concentrado salino de hemodiálise. Tais amostras, embora ligadas a diferentes áreas de pesquisa, apresentam similaridades relacionadas à presença de espécies metálicas como contaminantes, assim como a componentes majoritários. Métodos voltamétricos foram usados na determinação dos analitos em meios de alta concentração salina sem diluição, agentes mascarantes ou etapas de separação. Uma vez que mudanças na composição da matriz em análise podem afetar a magnitude da corrente de pico para os analitos, fatores que influenciam o comportamento voltamétrico das espécies e relacionados à composição das amostras (presença de matéria orgânica dissolvida e força iônica) foram avaliados. A análise de especiação de cromo foi executada pela adsorção de complexos Cr-DTPA no eletrodo de trabalho de mercúrio seguida de redissolução aliada a um passo catalítico. Observou-se a predominância de Cr(III) em fluido hidrotermal e, de Cr(VI), em água do mar, sendo o analito determinado em concentração desprezível na amostra de concentrado salino de hemodiálise. Determinou-se selênio por uma etapa de co-eletrólise de Cu2Se com posterior redissolução catódica do composto em meio ácido. Empregou-se o pré-tratamento por irradiação UV para a redução fotolítica de espécies não-eletroativas em Se(IV), assim como para a foto-oxidação da matéria orgânica, sendo a análise de especiação aplicada a amostras reais, para as quais não se evidenciou a presença de espécies de selênio. Fez-se o uso combinado de voltametria adsortiva e voltametria anódica de redissolução, para a determinação de antimônio. Escolheu-se o reagente ácido cloranílico para a formação de complexos com Sb(III) (pH 3,0), sendo a concentração total de antimônio avaliada por voltametria de redissolução anódica em HCl 5,0 mol L-1. Observou-se a predominância de Sb(III) em fluido hidrotermal e, de Sb(V), em água do mar. Não se evidenciou a presença de espécies de antimônio na amostra de concentrado salino de hemodiálise. Levando-se em conta as espécies de cromo, selênio e antimônio, uma dependência entre corrente de pico, potencial de deposição, tempo de deposição e velocidade de varredura foi observada em todos os meios investigados. Obtiveram-se limites de detecção adequados para a determinação dos analitos, sendo que as técnicas otimizadas consistem em procedimentos simples, rápidos e de baixo custo, aplicados à análise de especiação de elementos de relevância clínica e geoquímica, em amostras de alta concentração salina, com exatidão e sensibilidade.
15

Determinação voltamétrica de triclocarban e carbendazim em produtos de higiene pessoal e água potável

Lúcio, Maria Mônica Lacerda Martins 26 August 2015 (has links)
Submitted by Maike Costa (maiksebas@gmail.com) on 2016-05-11T12:53:38Z No. of bitstreams: 1 arquivo total.pdf: 6105657 bytes, checksum: 8404a0fcb54e3893c95fdfb017f0ac96 (MD5) / Made available in DSpace on 2016-05-11T12:53:38Z (GMT). No. of bitstreams: 1 arquivo total.pdf: 6105657 bytes, checksum: 8404a0fcb54e3893c95fdfb017f0ac96 (MD5) Previous issue date: 2015-08-26 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / Conselho Nacional de Pesquisa e Desenvolvimento Científico e Tecnológico - CNPq / Triclocarban (TCC) is a bactericide and fungicide widely used in personal care products, while carbendazim (MBC) is a fungicide widely used in cereal crops and a variety of fruits and vegetables, both are considered environmental contaminants. In this paper, propose the study of oxidation and determination of TCC using glassy carbon electrode (ECV) and the use of a carbon paste electrode modified with carbon nanotubes functionalized multi walled (EPC-NTCPMF) to determine MBC. Electrochemical detection of TCC and MBC was studied using different voltammetric techniques on a wide range of pH and the determination was performed on samples of soaps, only the TCC and drinking water at low concentrations, for both contaminants. For TCC, various oxidation processes were observed, however the peak P1 had greater sensitivity and selectivity in acetate buffer, pH 5.4 and was therefore used for the development of voltammetric methods, direct VOQ and adsorptive stripping voltammetry. For adsorptive stripping voltammetry, the linear response range was from 1.8 to 21 × 10-9 mol L-1 with a detection limit (LD) of 3.2 × 10-10 mol L-1, 1,000 times smaller than the LD obtained by direct VOQ. The method of adsorptive stripping voltammetry showed satisfactory levels of repeatability, 4.1% and reproducibility, 5.4% and was applied to determine TCC in soaps samples and an average recovery of 95.3% and drinking water with an average recovery apparent 95.4%. The MBC peaked main oxidation, almost reversible; the better sensitivity was achieved in H2SO4, pH 1.0 on the EPC-NTCPMF using VOQ. The linear response range is between 3 and 150 × 10-10 mol L-1 to LD 1.1 × 10-11 mol L-1. The method developed showed acceptable levels of repeatability, 4.6% and reproducibility, 6.2% and was applied for MBC determination in drinking water samples obtained average apparent recovery of 95.6%. The results obtained in the development of methods for determination of TCC and MBC showed excellent applicability for the studied samples, in addition to having advantages such as low cost instrumentation, analytical fast response, high sensitivity and selectivity. / Triclocarban (TCC) é um bactericida e fungicida amplamente utilizado em produtos de higiene pessoal, enquanto que o carbendazim (MBC) é um fungicida muito utilizado em culturas de cereais e numa grande variedade de frutas e vegetais, e ambos são considerados contaminantes ambientais. Nesse trabalho, propõe-se o estudo da oxidação e determinação do TCC utilizando eletrodo de carbono vítreo (ECV) e o uso de um eletrodo de pasta de carbono modificado com nanotubos de carbono de múltiplas paredes funcionalizado (EPC-NTCPMF) para determinação de MBC. A detecção eletroquímica de TCC e MBC foi estudada utilizando diferentes técnicas voltamétricas sobre uma ampla faixa de pH e a determinação foi realizada em amostras de sabonetes para TCC e em água potável em baixas concentrações para os dois contaminantes. Para TCC, foram observados seis processos de oxidação, entretanto, o processo correspondente ao pico P1 apresentou maior sensibilidade e seletividade em tampão acetato pH 5,4, portanto, foi utilizado para o desenvolvimento das metodologias voltamétricas, VOQ direta e VOQ com redissolução adsortiva. Para a VOQ com redissolução adsortiva, a faixa de resposta linear foi de 1,8 a 21 × 10-9 mol L-1 com limite de detecção (LD) de 3,2 × 10-10 mol L-1, 1.000 vezes menor do que o LD obtido por VOQ direta. O método de redissolução adsortiva apresentou níveis satisfatórios de repetibilidade, 4,1% e reprodutibilidade, 5,4% e foi aplicado para determinação de TCC em amostras de sabonetes, obtendo uma recuperação média de 95,3% e água potável com uma média de recuperação aparente de 95,4%. O MBC apresentou um pico de oxidação principal, quase reversível e a maior sensibilidade foi alcançada em H2SO4, pH 1,0, sobre o EPC-NTCPMF, utilizando VOQ. A faixa de resposta linear está entre 3 e 150 × 10-10 mol L-1 com LD de 1,1 × 10-11 mol L-1. O método desenvolvido apresentou níveis satisfatórios de repetibilidade, 4,6% e reprodutibilidade, 6,2% e foi aplicado para determinação de MBC em amostras de água potável, obtendo-se valor médio de recuperação aparente de 95,6%. Os resultados obtidos no desenvolvimento dos métodos para determinação de TCC e MBC demonstraram excelente aplicabilidade para as amostras estudadas, além de apresentarem vantagens como instrumentação de baixo custo, rápida resposta analítica, elevada sensibilidade e seletividade.
16

Síntese, caracterização e aplicação do alfa-hidróxido de níquel associado a óxido de grafeno reduzido como sensor voltamétrico / Synthesis, characterization and application of alpha-nickel hydroxide associated with graphene oxide and reduced graphene oxide as a voltammetric sensor

Silva, Aleckson Souto 18 June 2018 (has links)
Submitted by Luciana Ferreira (lucgeral@gmail.com) on 2018-07-27T14:20:48Z No. of bitstreams: 2 Dissertação - Aleckson Souto Silva - 2018.pdf: 4136117 bytes, checksum: 733a03156cbc3f72a6ac8bc4daff6b54 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2018-07-27T14:36:23Z (GMT) No. of bitstreams: 2 Dissertação - Aleckson Souto Silva - 2018.pdf: 4136117 bytes, checksum: 733a03156cbc3f72a6ac8bc4daff6b54 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2018-07-27T14:36:23Z (GMT). No. of bitstreams: 2 Dissertação - Aleckson Souto Silva - 2018.pdf: 4136117 bytes, checksum: 733a03156cbc3f72a6ac8bc4daff6b54 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2018-06-18 / Conselho Nacional de Pesquisa e Desenvolvimento Científico e Tecnológico - CNPq / The present work aims to the development of voltammetric sensors based on α-Ni(OH) 2 /GO and α- Ni(OH) 2 /rGO nanocomposites for detection and determination of uric acid, paracetamol and ascorbic acid by differential pulse voltammetry. For this, nanostructured nickel hydroxide stabilized in the alpha polymorphic form associated with graphene oxide (GO) or reduced graphene oxide (rGO) were synthesized and characterized. The method used for synthesis of α- Ni(OH) 2 was Tower’s modified, for oxidized graphite was that of Hummers and reduced graphene oxide was that of Stankovich. X-ray diffractometry, confocal Raman spectroscopy, cyclic voltammetry, transmission electron microscopy, infrared spectroscopy and thermogravimetric analysis were used to characterize the synthesized nanomaterials. The presence of graphene oxide and reduced graphene oxide with nickel hydroxide was confirmed by the results. The nickel hydroxide/graphene composites arouse great interest for the development of electrochemical sensors due to their good cost-effectiveness, biocompatibility and high catalytic effect. The thin films of α-Ni(OH) 2 /GO and α-Ni(OH) 2 /rGO showed better electrical properties compared to thin film of α-Ni (OH) 2 and it can be attributed to the increase in surface area and electrical conductivity. Through the differential pulse voltammetry, α-Ni(OH) 2 /GO and α-Ni(OH) 2 /rGO films presented good linear relationship between peak current and uric acid, ascorbic acid and paracetamol concentrations in the range concentration of 0.099 mmol.L -1 – 1.38 mmol.L -1 , with linear coefficients higher than 0.993 and detection limit lower than 2,645x10 -5 mol.L -1 for uric acid, 2,080x10 -5 mol. L -1 for ascorbic acid and 4.248x10 -5 mol. L -1 for paracetamol. / Este trabalho tem como objetivo o desenvolvimento de sensores voltamétricos baseados em nanocompósitos de α-Ni(OH) 2 /GO e α-Ni(OH) 2 /rGO para detecção e determinação de ácido úrico, paracetamol e ácido ascórbico através da voltametria de pulso diferencial. Para isso, hidróxido de níquel nanoestruturado e estabilizado na fase polimórfica alfa associado a óxido de grafeno (GO)ou óxido de grafeno reduzido (rGO) foram sintetizados e caracterizados. O método utilizado para a síntese do α-Ni(OH) 2 foi o de Tower modificado, o óxido de grafeno foi o de Hummers e o óxido de grafeno reduzido foi o de Stankovich. Para a caracterização dos nanomateriais sintetizados foram empregados a difratometria de raios-X, espectroscopia Raman confocal, voltametria cíclica, microscopia eletrônica de transmissão, espectroscopia no infravermelho e análises termogravimétricas. Sendo confirmados através dos resultados a presença de óxido de grafeno e óxido de grafeno reduzido junto ao hidróxido de níquel. Os compósitos de hidróxido de níquel/grafeno despertam grande interesse para o desenvolvimento de sensores eletroquímicos, devido a sua boa relação custo-benefício, biocompatibilidade e alto efeito catalítico. Os filmes finos de α-Ni(OH) 2 /GO e α-Ni(OH) 2 /rGO apontaram melhores propriedades elétricas compara ao filme fino de α-Ni(OH) 2 podendo ser atribuído ao aumento da área superficial e aumento da condutividade elétrica. Através da voltametria de pulso diferencial os filmes α-Ni(OH) 2 /GO e α- Ni(OH) 2 /rGO apresentaram boa relação linear entre a corrente de pico e a concentração de ácido úrico, ácido ascórbico e paracetamol na faixa de concentração de 0,099 mmol.L -1 – 1,38 mmol.L -1 , com coeficientes lineares superiores a 0,993 e limite de detecção inferiores a 2,645x10 -5 mol.L -1 para o ácido úrico, 2,080x10 -5 mol.L -1 para o ácido ascórbico e 4,288x10 -5 para o paracetamol.

Page generated in 0.2363 seconds